  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "xr8720t",
  "name": "XR8720T",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XR8720T Updates",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 4,
      "rss": "/xr8720t/urgent/rss.xml",
      "api": "/api/xr8720t/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 4,
      "rss": "/xr8720t/recommended/rss.xml",
      "api": "/api/xr8720t/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 5,
      "rss": "/xr8720t/optional/rss.xml",
      "api": "/api/xr8720t/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xr8720t/bios/rss.xml",
      "api": "/api/xr8720t/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/xr8720t/boss/rss.xml",
      "api": "/api/xr8720t/boss"
    },
    {
      "slug": "chassis-system-management",
      "label": "Chassis System Management",
      "count": 1,
      "rss": "/xr8720t/chassis-system-management/rss.xml",
      "api": "/api/xr8720t/chassis-system-management"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/xr8720t/diagnostics/rss.xml",
      "api": "/api/xr8720t/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xr8720t/drivers-for-os-deployment/rss.xml",
      "api": "/api/xr8720t/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 3,
      "rss": "/xr8720t/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xr8720t/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xr8720t/firmware/rss.xml",
      "api": "/api/xr8720t/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xr8720t/idrac/rss.xml",
      "api": "/api/xr8720t/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 1,
      "rss": "/xr8720t/network/rss.xml",
      "api": "/api/xr8720t/network"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/xr8720t/systems-management/rss.xml",
      "api": "/api/xr8720t/systems-management"
    }
  ],
  "count": 13,
  "updates": [
    {
      "id": "837f52bcdf77c2d14310498f7dd4952e13c37aa4c6fdc01265b9a428e061657d",
      "name": "Dell EMC iDRAC Service Module Installer for OS DUP, v6.2.0.0",
      "version": "6.2.0.0",
      "release_id": "JDJH3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-11-09T07:17:23Z",
      "released": "2026-10-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15095008M/5/Systems-Management_Application_JDJH3_WN64_6.2.0.0_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDJH3",
      "size": 34422592,
      "reboot_required": false,
      "description": "iDRAC Service Module (iSM) is a lightweight software service that better integrates operating system (OS) features with iDRAC and can be installed on Dell PowerEdge 15G and above servers. iSM provides OS-related information to iDRAC and adds capabilities such as Lifecycle Controller log event replication into the OS log, iDRAC SNMP alerts via OS, iDRAC hard reset and remote full Power Cycle. iSM has very little impact on the host processor and smaller memory footprint, thus expanding iDRAC management to the supported host operating systems.",
      "revision_history": "NA"
    },
    {
      "id": "0977dfbae8a40a6e966730b9138c338cd5e985d9f63aa6ac5dd14dcf8700cee4",
      "name": "iDRAC 1.30.65.51",
      "version": "1.30.65.51",
      "release_id": "C21YH",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-06T13:39:20Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213660M/1/iDRAC-with-Lifecycle-Controller_Firmware_C21YH_WN64_1.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C21YH",
      "size": 357946640,
      "reboot_required": false,
      "description": "iDRAC 1.30.65.51",
      "revision_history": "Fixes\n- Fixed the issue where Serbia was missing from the country code list in the iDRAC SSL/TLS CSR interface.\n- Fixed the issue where iDRAC 1.30.40.51 returns HTTP 400 when accessing Web GUI via FQDN despite HostHeaderCheck being disabled.\n- Fixed the issue where iDRAC time never reverts to RTC if NTP is unavailable.\n- Fixed the issue where SWC9048 error message appears when trying to launch iDRAC IP from UI after updating iDRAC firmware with FIPS enabled.\n- Fixed the issue where SystemCurrentCapLimit and SystemCurrentCapSetting options were missing in racadm get/set system.ServerPwr output while GridCurrentCapLimit settings were exposed.\n- Fixed the issue where STOR090 error occurred when failing to import OMEnt template and SCP when Dedicated HotSpare is present on PERC H965i.\n- Fixed the issue where iDRAC10 SCP export command fails via RACADM for iDRAC firmware version 1.30.40.51.\n- Fixed the issue where GPU Temperature Probe Readings were missing in SNMP and ProbeStatus appeared in unknown state after upgrading to iDRAC 1.30.40.51.\n- Fixed the issue where fans were spinning at 100% when system idle on PowerEdge XE9785 with AMD Pensando Pollara 400 AI Network Interface Card (NIC).\n\n\nEnhancements:\n- Added filter options in iDRAC for SAS address.\n- Fixed the issue where banner for functional pages was still observed when system is in lockdown mode.\n- Added Redfish support to delete AD/LDAP certificates.\n- Populated Redfish Volume Identifiers with durable identifier for PERC RAID virtual disks.\n- Added support to Redfish action EventService.SubmitTestEvent to send test events to Server-Sent Events.\n- Added Redfish support to retrieve configuration preview results for a Job ID.\n- Added Redfish support to reset Storage Controller to defaults.\n- Updated battery page and rollup status design.\n- Added the ability to mount virtual images from S3 for iDRAC.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification.\n- Improved Redfish error messaging for BootSourceOverride failure in iDRAC10.\n- Added OpenID Connect with Azure Entra ID support.\n- Added low privilege iDRAC Operator role.\n- Enabled email alerts for thermal-related GPU/TMP events.\n- Added SMTP modern authentication (OAuth2) support.\n- Enabled email alerts for critical PCI errors (PCI3039/PCI3040) in iDRAC10.\n- Added iDRAC10 BIOS Console Log Retention for serviceability.\n- Added block-level erase and cryptographic validation for iDRAC partitions in SystemErase.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero-Touch Bootstrap.\n- Added support for SID/OPAL/PSID drive status property.\n- Enabled Full APO (Automatic Power On) support for FullPowerReset.\n- Added fan board page health rollup into overall system health.\n- Fixed iDRAC delay in MEM message logging that caused incorrect event ordering.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message.\n- Aligned MultipartUpload ApplyTime behavior with SimpleUpdate (OnStartUpdateRequest).\n- Added BIN Catalog update support.\n- Added native iDRAC10 support for Open Telemetry (OTEL) metric streaming.\n- Added Component-Level Firmware Update and Discoverability via Redfish.\n- Added support for custom HTTP ports for InstallFromRepository via iDRAC UI, Redfish, and RACADM.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior.\n- Added iDRAC support for controlling the SMA_OUT source select.\n- Added support in iDRAC to control the timing module Write_en pin and timing module reset pin with host control via Redfish.\n- Enabled PSU firmware update when single PSU is installed.\n- Added iDRAC CMP V2 support on PowerEdge XR8720T.\n- Added iDRAC uptime to sysinfo.\n- Enhanced iDRAC10 UI usability with VLAN placement, search/filter"
    },
    {
      "id": "76245d0a584c5ccc82e289fc13f517d6fe16339b10aa85c49a062f45e8a4f53d",
      "name": "DELL System Update, v.2.3.0.2",
      "version": "2.3.0.2",
      "release_id": "RDVR3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-11-06T11:10:35Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213121M/1/Systems-Management_Application_RDVR3_WN64_2.3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RDVR3",
      "size": 30983200,
      "reboot_required": false,
      "description": "DELL System Update (DSU) is a software designed to facilitate the application of updates on various Dell systems. Using DSU you can:\n1.Identify the available updates, select the relevant updates, and deploy the updates on multiple systems.\n2.Maintain consistency in terms of interface and versions across Operating Systems, Repositories, and Systems.",
      "revision_history": "Enhancement :\n\nOS native support with passthrough and rsystemtype iDRAC \n\nFixes :\n\nSecurity Issues"
    },
    {
      "id": "5ab02e5d49fa4efc02274d3d1e2fac8fd04b378ba529d98fcfeaf2e47d609ef8",
      "name": "Dell Server PowerEdge XR8720t BIOS Version 1.4.4",
      "version": "1.4.4",
      "release_id": "GG7JN",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-10-28T06:57:52Z",
      "released": "2026-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15176654M/1/XR8720T_BIOS_GG7JN_WN64_1.4.4.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GG7JN",
      "size": 44480264,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced features sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Fixes:\n- Fixed an issue where Package C-States were not disabled by default under the Telco Optimized Profile workload setting.\n \nEnhancements:\n- Added support for DPLL and GNSS firmware version reporting.\n- Added support for NVMe-oF feature.\n- Added support for automatic PCIe bifurcation configuration for specific PCIe CEM cards, such as M.2 carrier cards, without requiring manual BIOS configuration.\n- Enhanced BIOS authentication following BIOS DUP updates.\n- Added support for BIOS configuration through iDRAC SMA, enabling Reset to Default (RTD) and BIOS configuration operations within the same boot cycle, thereby reducing additional reboot requirements.\n- Updated the following:\n- Intel processor and memory reference codes to Kaseyville Granite Rapids-D Post Launch Release Five (PLR6) BKC\n- Intel processor microcode to version 0x310 for Xeon 6 SoC Extreme Core Count (XCC) and High Core Count (HCC) processors.\n- This release contains security fixes that address one or more vulnerabilities. Dell recommends that you run the most recent available version of the software and apply any security updates at the earliest opportunity. Upon completion of coordinated vulnerability disclosure activities, Dell will publish a Dell Security Advisory (DSA) providing additional details about the vulnerabilities and associated security updates. Customers are encouraged to subscribe to Dell Security Advisories to receive notifications when advisories are published."
    },
    {
      "id": "2784cac0b8b58ea70ad630208898d6eb97e9b03ca201d3538f7cdf540045f1b2",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N",
      "version": "1.3.1",
      "release_id": "VMDWF",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:48Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652186M/3/Express-Flash-PCIe-SSD_Firmware_VMDWF_WN64_1.3.1_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VMDWF",
      "size": 28699000,
      "reboot_required": true,
      "description": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N.",
      "revision_history": "Fixes: \n\nFW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "b31af8d25442f47d287b9165621c02201f15b930f033645f7c931dba1ce3dae7",
      "name": "Dell OS Driver Pack",
      "version": "26.08.02",
      "release_id": "5XVNX",
      "category": "Drivers for OS Deployment",
      "category_slug": "drivers-for-os-deployment",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-08-17T06:37:41Z",
      "released": "2026-08-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14907780M/1/Drivers-for-OS-Deployment_Application_5XVNX_WN64_26.08.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5XVNX",
      "size": 52811920,
      "reboot_required": false,
      "description": "OS Driver Pack for PowerEdge 17G servers. This Driver Pack contains applicable storage, Drivers for OCP cards and chipset drivers to support OS installation using the Dell Lifecycle Controller",
      "revision_history": "N/A"
    },
    {
      "id": "02a933f56275ab49fdaa46ae69cb9d50ef35243a3a32b74178aa00a1002fc5ad",
      "name": "Intel NIC Firmware Release 30.5 for Intel E830 Adapter and Intel E825 LOM",
      "version": "30.5.0.57",
      "release_id": "69TRD",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-29T15:33:07Z",
      "released": "2026-07-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14838807M/1/XR8720T_Network_Firmware_69TRD_WN64_30.5.0.57_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=69TRD",
      "size": 66708368,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Release 30.5 on Intel E825 LOM and Intel E830 Adapter.",
      "revision_history": "View the readme.txt and fw_release_e830_e825.txt for details"
    },
    {
      "id": "3f4b661eda52512bdd9405ca353725045d5c9fc1f6c80361b17b6d72341ffbec",
      "name": "Dell product PowerEdge Chassis Management firmware",
      "version": "2.16",
      "release_id": "0MKY1",
      "category": "Chassis System Management",
      "category_slug": "chassis-system-management",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-04-17T02:44:44Z",
      "released": "2026-04-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14444189M/1/Chassis-System-Management_Firmware_0MKY1_WN64_2.16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0MKY1",
      "size": 5540008,
      "reboot_required": false,
      "description": "NA"
    },
    {
      "id": "8c3d285c600b7b3b6ae9c3526b8be2ffe5a4fc5faf7961756fb3a005c478e8e1",
      "name": "Dell PowerEdge XR8720t Heater Manager firmware",
      "version": "1.0.2.0",
      "release_id": "D1R57",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-29T09:12:50Z",
      "released": "2026-01-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14145952M/1/XR8720T_Firmware_D1R57_WN64_1.0.2.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D1R57",
      "size": 5216096,
      "reboot_required": false,
      "description": "PowerEdge Heater Manager firmware",
      "revision_history": "Class E: No Image Impact Change-Very Low: New hardware or software that does not require new software, BIOS, or system reboot."
    },
    {
      "id": "b0d897e52dc30af4103f492d39663bce1e0e6a943278a6956ee347963677fd54",
      "name": "Dell 64 Bit uEFI Diagnostics, version 4303",
      "version": "4303A53",
      "release_id": "MG1RW",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2025-12-12T19:45:02Z",
      "released": "2025-12-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13978249M/1/XR8720T_Diagnostics_Application_MG1RW_WN64_4303A53_4303.53.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MG1RW",
      "size": 19094000,
      "reboot_required": false,
      "description": "Dell Diagnostics is designed to verify the proper operation of the hardware installed in your system outside of a high-level operating system environment. The files in this group can be used to update these diagnostics on a system with a Lifecycle Controller.",
      "revision_history": "This release contains minor bug fixes and enhancements."
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "1752a0699e2d7f6c98f80ebe810d009345d7d50fcdb40d01489f42fec9ae2527",
      "name": "BOSS-N1 Modular DC-MHS Firmware",
      "version": "2.2.13.2037",
      "release_id": "KMDGP",
      "category": "BOSS",
      "category_slug": "boss",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-07-10T10:56:11Z",
      "released": "2025-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13366141M/1/BOSS_Firmware_KMDGP_WN64_2.2.13.2037_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KMDGP",
      "size": 18372512,
      "reboot_required": true,
      "description": "BOSS-N1 Modular DC-MHS Package Version 2.2.13.2034",
      "revision_history": "Fixes - Yes\nEnhancements - Yes , please refer the release notes for more details"
    }
  ]
}