  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "xr5610",
  "name": "XR5610",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XR5610 Updates",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 19,
      "rss": "/xr5610/urgent/rss.xml",
      "api": "/api/xr5610/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 58,
      "rss": "/xr5610/recommended/rss.xml",
      "api": "/api/xr5610/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 38,
      "rss": "/xr5610/optional/rss.xml",
      "api": "/api/xr5610/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xr5610/bios/rss.xml",
      "api": "/api/xr5610/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/xr5610/boss/rss.xml",
      "api": "/api/xr5610/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/xr5610/chipset/rss.xml",
      "api": "/api/xr5610/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/xr5610/diagnostics/rss.xml",
      "api": "/api/xr5610/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xr5610/drivers-for-os-deployment/rss.xml",
      "api": "/api/xr5610/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 42,
      "rss": "/xr5610/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xr5610/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xr5610/firmware/rss.xml",
      "api": "/api/xr5610/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xr5610/idrac/rss.xml",
      "api": "/api/xr5610/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 23,
      "rss": "/xr5610/network/rss.xml",
      "api": "/api/xr5610/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 13,
      "rss": "/xr5610/sas-drive/rss.xml",
      "api": "/api/xr5610/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 6,
      "rss": "/xr5610/sas-non-raid/rss.xml",
      "api": "/api/xr5610/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 12,
      "rss": "/xr5610/sas-raid/rss.xml",
      "api": "/api/xr5610/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/xr5610/security/rss.xml",
      "api": "/api/xr5610/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 9,
      "rss": "/xr5610/serial-ata/rss.xml",
      "api": "/api/xr5610/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/xr5610/systems-management/rss.xml",
      "api": "/api/xr5610/systems-management"
    }
  ],
  "count": 115,
  "updates": [
    {
      "id": "837f52bcdf77c2d14310498f7dd4952e13c37aa4c6fdc01265b9a428e061657d",
      "name": "Dell EMC iDRAC Service Module Installer for OS DUP, v6.2.0.0",
      "version": "6.2.0.0",
      "release_id": "JDJH3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-11-09T07:17:23Z",
      "released": "2026-10-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15095008M/5/Systems-Management_Application_JDJH3_WN64_6.2.0.0_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDJH3",
      "size": 34422592,
      "reboot_required": false,
      "description": "iDRAC Service Module (iSM) is a lightweight software service that better integrates operating system (OS) features with iDRAC and can be installed on Dell PowerEdge 15G and above servers. iSM provides OS-related information to iDRAC and adds capabilities such as Lifecycle Controller log event replication into the OS log, iDRAC SNMP alerts via OS, iDRAC hard reset and remote full Power Cycle. iSM has very little impact on the host processor and smaller memory footprint, thus expanding iDRAC management to the supported host operating systems.",
      "revision_history": "NA"
    },
    {
      "id": "76245d0a584c5ccc82e289fc13f517d6fe16339b10aa85c49a062f45e8a4f53d",
      "name": "DELL System Update, v.2.3.0.2",
      "version": "2.3.0.2",
      "release_id": "RDVR3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-11-06T11:10:35Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213121M/1/Systems-Management_Application_RDVR3_WN64_2.3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RDVR3",
      "size": 30983200,
      "reboot_required": false,
      "description": "DELL System Update (DSU) is a software designed to facilitate the application of updates on various Dell systems. Using DSU you can:\n1.Identify the available updates, select the relevant updates, and deploy the updates on multiple systems.\n2.Maintain consistency in terms of interface and versions across Operating Systems, Repositories, and Systems.",
      "revision_history": "Enhancement :\n\nOS native support with passthrough and rsystemtype iDRAC \n\nFixes :\n\nSecurity Issues"
    },
    {
      "id": "32cba0424a9d705494c82dbc9641cf64613fcacbc440c2497327e80b0f1906c3",
      "name": "PERC12 H965e Adapter RAID Controller firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "378K2",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:41:09Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194809M/2/SAS-RAID_Firmware_378K2_WN64_8.19.0.0.18-65_A10.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=378K2",
      "size": 30451168,
      "reboot_required": false,
      "description": "This release updates the firmware residing on H965e Adapter RAID Controller to package8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "ef67956cb25fd3a7709bd5ab3db4f05c7dcc8cb05a69757e03b5656bc773aa7c",
      "name": "PERC H965i Adapter RAID Controller firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "520P8",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:39:55Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194782M/2/SAS-RAID_Firmware_520P8_WN64_8.19.0.0.18-65_A13.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=520P8",
      "size": 30451152,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H965i Adapter RAID Controller to package 8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active.\nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements:\n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "3c42a5d5d6593d1bb6afbb03bfc0943458d93671a8a9b79d91ec42193d56871e",
      "name": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "GF3PY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-11-03T17:31:07Z",
      "released": "2026-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199882M/1/Express-Flash-PCIe-SSD_Firmware_GF3PY_WN64_1.5.0_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GF3PY",
      "size": 38306408,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release"
    },
    {
      "id": "a5d07ba978a43fb98b620e9772c2b9781c7c88a95244ad0c3d5d40b728298959",
      "name": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "NKCW4",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-03T15:09:31Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199461M/1/SAS-RAID_Driver_NKCW4_WN64_8.19.6.0_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKCW4",
      "size": 17814352,
      "reboot_required": true,
      "description": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\n\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\n\nDriver Code optimization in IO completion path."
    },
    {
      "id": "c4353be1f75b45627e460e935d416b30929f3c9ceffd49a4970f42706b141bab",
      "name": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "YTR3P",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-02T18:49:59Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195250M/1/SAS-RAID_Driver_YTR3P_WN64_8.19.6.0_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YTR3P",
      "size": 17813192,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\nDriver Code optimization in IO completion path."
    },
    {
      "id": "fd0732c1a5436e1e87e2f3b578749cbde7f0ad1acade4f2c68a4395a4ec03d68",
      "name": "iDRAC 7.30.65.51",
      "version": "7.30.65.51",
      "release_id": "77JC4",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-26T15:08:42Z",
      "released": "2026-10-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15169022M/1/iDRAC-with-Lifecycle-Controller_Firmware_77JC4_WN64_7.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=77JC4",
      "size": 244930552,
      "reboot_required": false,
      "description": "The Integrated Dell Remote Access Controller (iDRAC) is designed to make server administrators more productive and improve the overall availability of Dell servers. iDRAC also provides an out-of-band mechanism for configuring the platform, applying firmware updates, saving or restoring a system backup, or deploying an operating system, either by using a GUI or a remote scripting language, such as Redfish or RACADM.",
      "revision_history": "Fixes:\n- Fixes the issue where email alert is not enabled for LCS0009 event on PowerEdge XE8640 systems.\n- Fixes the issue where RAC1195 events for local user account deletion are missing in iDRAC9 releases by instrumenting the user deletion endpoint to generate audit logs.\n- Fixes the issue where Active Directory authentication fails due to DNS Type = ANY by changing the DNS query from T_ANY to T_SRV to comply with RFC8482.\n- Fixes the issue where CPU throttling occurs when PSU power input drops on PowerEdge T550 systems since iDRAC 7.20.30.00 by addressing the power FTR loop issue.\n- Fixes the issue where firmware update notifications on homepage use cached recommended updates by addressing the deletion of lc_validator_output.xml during iDRAC reboot or system erase operation.\n- Fixes the issue where fan failures occur on PowerScale R660 nodes after firmware updates by addressing the timing issue between BIOS updates and fan initialization.\n\nEnhancements:\n- Made Subject Alternative Name (SAN) mandatory for SSL/TLS CSR generation in iDRAC9.\n- Upgraded Poky for iDRAC9 16G.\n- Upgraded kernel to version 6.12.63 for iDRAC9 16G.\n- Added SMTP modern authentication (OAuth2) support for iDRAC9 16G.\n- Added TPM PCR Measurements reporting in Redfish for iDRAC9.\n- Added new option \"LCLOG\" in SystemErase for clearing LC logs without host reboot.\n- Added China Data Sanitization Compliance with Block Erase support on drives via iDRAC for 16G.\n- Leveraged iDRAC Early Video for Services Modernization on 16G.\n- Optimized 16G CPLD Firmware Update for Services Modernization.\n- Implemented correct and reliable Redfish StartUpdate action for 16G.\n- Enabled optional auto deletion of completed/failed iDRAC Jobs for 16G.\n- Enabled CPLD and iDRAC firmware updates with a single iDRAC reboot for 16G.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior for 16G.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message for 16G.\n- Added Leak Warranty Void Warning Message support for iDRAC platforms 16G.\n- Updated OID for SCV replacement certificate on 16G/15G platforms.\n- Added security (firmware) assertions from iDRAC9 to SCV certificate.\n- Added iDRAC persistence and reconciliation capability for SCV Delta Certificate upload synchronization.\n- Enabled email alerts for thermal-related GPU/TMP events for 16G.\n- Enabled iLKM support on PowerEdge XR8620t.\n- Added Microsoft Entra ID (formerly Azure AD) support for OpenID Connect for 16G.\n- Migrated iDRAC9 GUI from AngularJS to Angular Framework for 16G.\n- Addressed Channel Firmware SED integration and stability issues for 16G.\n- Updated Redfish specification and schema for the 16G March release.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification for iDRAC9.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero Touch Bootstrap for 16G.\n- Fixed BootProgress/LastState property value showing as \"OSRunning\" when the server is not booted to the operating system.\n- Improved SEKM key retrieval retry and logging.\n- Added iDRAC uptime to sysinfo for 16G.\n- Added GetBIOSTime functionality and SetBIOSTime handling for unsupported BIOS for 16G.\n- Exposed Redfish APIs for Hardware Configuration Validation control in iDRAC for 16G.\n- Added support for SID/OPAL/PSID drive status property.\n- Added SDPM Battery Inventory and BBU Replacement Behavior for 16G."
    },
    {
      "id": "a2c0b63fa50d2f9175300cc8041608e02ff774947b5fbbbbe5ec847934e57b8f",
      "name": "Dell Server PowerEdge BIOS Version 2.12.2",
      "version": "2.12.2",
      "release_id": "VTDD9",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-10-19T10:46:49Z",
      "released": "2026-10-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15144333M/1/BIOS_VTDD9_WN64_2.12.2.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VTDD9",
      "size": 45307816,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced feature sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Fixes:\n- N/A.\n\nEnhancements:\n- Updated the followings:\n  * Intel processor and memory reference codes to IPU 2026.4\n  * Intel processor microcode to version 0x690 in the 4th Generation Intel Xeon Scalable Processors Family.\n  * Intel processor microcode to version 0x300 in the 5th Generation Intel Xeon Scalable Processors Family.\n- This release contains security fixes that address one or more vulnerabilities. Dell recommends that you run the most recent available version of the software and apply any security updates at the earliest opportunity. Upon completion of coordinated vulnerability disclosure activities, Dell will publish a Dell Security Advisory (DSA) providing additional details about the vulnerabilities and associated security updates. Customers are encouraged to subscribe to Dell Security Advisories to receive notifications when advisories are published."
    },
    {
      "id": "318fefd2743ce3a042428d9e8d722b8a862af777cc9df710c689ecd125c66516",
      "name": "Broadcom NetXtreme-E Network Device Firmware (Dell) 23.8.1",
      "version": "38.11.91.00",
      "release_id": "H3TR4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-10-13T23:36:18Z",
      "released": "2026-10-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15122845M/1/Network_Firmware_H3TR4_WN64_38.11.91.00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3TR4",
      "size": 84351360,
      "reboot_required": false,
      "description": "This release provides updated network controller firmware for the Broadcom NetXtreme-E devices.   This release should be used with the Broadcom NetXtreme-E 23.8 device drivers."
    },
    {
      "id": "2784cac0b8b58ea70ad630208898d6eb97e9b03ca201d3538f7cdf540045f1b2",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N",
      "version": "1.3.1",
      "release_id": "VMDWF",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:48Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652186M/3/Express-Flash-PCIe-SSD_Firmware_VMDWF_WN64_1.3.1_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VMDWF",
      "size": 28699000,
      "reboot_required": true,
      "description": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N.",
      "revision_history": "Fixes: \n\nFW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "a9017f3140289b317e112d789c28482d6226881bc8dd0e05c58dc4640963ca51",
      "name": "MICRON 5200 RI/ MU SATA \u0026apos;F006\u0026apos; FW for model number(s) MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, MTFDDAK1T9TDN, MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD",
      "version": "F006",
      "release_id": "DJFFV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T13:57:57Z",
      "released": "2026-06-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14570492M/2/Serial-ATA_Firmware_DJFFV_WN64_F006_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DJFFV",
      "size": 26417352,
      "reboot_required": false,
      "description": "This release contains Micron firmware F006 for models MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD, MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, and MTFDDAK1T9TDN for all operating systems.",
      "revision_history": "LogEntryCnt = 65,535 \n- Exit the workload log function directly; no workload log entry is recorded.\nLogEntryCnt = 0 to 65,534\n- Workload log recording continues as originally designed."
    },
    {
      "id": "84424b59e4b03b97dcd05979da85efce26d61c206d7cbf88df0ae2523c8269c6",
      "name": "NVIDIA Mellanox Firmware Release 26.50.10.02 for Dell Customized NVIDIA Mellanox ConnectX-6 LX Ethernet Adapters",
      "version": "26.50.10.02",
      "release_id": "HW6K0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T18:44:16Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15080928M/1/Network_Firmware_HW6K0_WN64_26.50.10.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HW6K0",
      "size": 45977560,
      "reboot_required": true,
      "description": "NVIDIA Mellanox Firmware Release 26.50.10.02 for Dell Customized NVIDIA Mellanox ConnectX-6 LX Ethernet Adapters on Dell 14G and 15G and 16G servers. This release provides continued code optimization to improve performance."
    },
    {
      "id": "c6f2ad0676741ff665ce9fcf695a0917988e577ea0a3b678a9e83d7902b809cd",
      "name": "NVIDIA Mellanox Firmware Release 22.50.10.02 for Dell Customized NVIDIA Mellanox ConnectX-6 DX Adapters",
      "version": "22.50.10.02",
      "release_id": "40HW6",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T15:06:30Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15080319M/1/Network_Firmware_40HW6_WN64_22.50.10.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=40HW6",
      "size": 46496216,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Dell customized Nvidia Mellanox firmware release 22.50.10.02 on NVIDIA Mellanox ConnectX-6 DX adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "f070ff471ae542821babbddf2837e07754dda176c5fb1ae19c1b1d3f76c4acb1",
      "name": "TPM Field Firmware Update, 7.2.4.1",
      "version": "7.2.4.1",
      "release_id": "T2F4J",
      "category": "Security",
      "category_slug": "security",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-25T18:03:57Z",
      "released": "2026-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15066223M/1/Security_Firmware_T2F4J_WN64_7.2.4.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T2F4J",
      "size": 30130872,
      "reboot_required": true,
      "description": "TPM Field Firmware Update, 7.2.4.1, for use with BIOS 2.9.4 (457WM) or later only"
    },
    {
      "id": "1946160ed0d0cb3359a20dfca14e8078ecac5f014fd8979c0efcaa3a71e82245",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "version": "1.1.0",
      "release_id": "4WN4V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-23T16:20:58Z",
      "released": "2026-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14428501M/2/Express-Flash-PCIe-SSD_Firmware_4WN4V_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4WN4V",
      "size": 34529136,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n1. Modified the FW to track second level read recovery triggers.\n2. Developed a firmware fix to add separate queues in the CPU coupled memory to monitor and control the flow of push \u0026 pop entries in the linked list to eliminate any possibility of unexpected concurrent accesses. A dedicated CPU is used for this solution to minimize performance impact.\n3. Modified the FW to set the pointer value to the designated structured memory area.\n4. Updated the firmware to optimize internal operations under this back-to-back power cycle scenario to properly manage APL interrupt.\n5. Updated the firmware to check the thermal throttling stage and manage the resource allocation appropriately before the initiating APL handling.\n6. Enhanced the firmware to handle the back-to-back PERST# operations to ensure that no transitions are missed.\n7. Updated the firmware to increase the PCIe bridge timeout to 1ms\n\nEnhancements:  \n1. Updated the FW to increase the CAP.TO value to 30 seconds for 9550 product family\n2. Updated the Firmware to correct the eye measurement algorithm to appropriately handle PCIe errors conditions.\n3. Enhanced the firmware to optimize folding operations under these specific workloads to improve performance consistency.\n4. Updated the firmware to keep the activity LED on when the host disables the controller (CC.EN=0)"
    },
    {
      "id": "48c5469a4a346a44cc4729143b3df57c3c9d8a12638878a02ea6a9cd86561b51",
      "name": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "version": "1.0.2",
      "release_id": "1W7Y8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-22T19:07:37Z",
      "released": "2026-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568456M/2/Express-Flash-PCIe-SSD_Firmware_1W7Y8_WN64_1.0.2_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1W7Y8",
      "size": 35321280,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected SPDM data offset used when calculating the SPDM manifest.\n2. Enhanced NVMe-MI logic.\n3. Fixed NVMe-MI message response delays; reponses to all NVMe-MI messages within a 100ms timeout period.\n4. Restrict SMBus communication to when the drive is ready to service MCTP/Basic.\n\nEnhancements:\n\n1. Enhanced MCTP processing over SMBus while SMBus is in a reset state.\n2. DUP support for ARM platforms added.\n3. DUP support updated for PERC 12 and 13."
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "1dfc69717a0c357d41f49286fe59e78a2c4fcacd649a8c48425eb8d24d3adb47",
      "name": "Windows 2022 drivers for H975i, H965i, H365i and HBA465 controllers",
      "version": "8.14.6.0",
      "release_id": "V3P66",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-09-09T13:37:59Z",
      "released": "2026-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14017149M/4/SAS-RAID_Driver_V3P66_WN64_8.14.6.0_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3P66",
      "size": 17570512,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes:\n=====\nResolved system crash observed after factory reset of the controller.\nFixed issue where crash dump was not generated when Virtualization-Based Security (VBS) was enabled.\n\nEnhancement:\n===========\nNA"
    },
    {
      "id": "dbcfb5f8d4ca05fbd05677da4e2f7ab6b9a14ce9ea98e71643d928f51d2df178",
      "name": "PERC H355 RAID Controller Firmware",
      "version": "52.38.0-6897",
      "release_id": "V39Y1",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-08T05:38:01Z",
      "released": "2026-08-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14921744M/3/SAS-RAID_Firmware_V39Y1_WN64_52.38.0-6897_A07_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V39Y1",
      "size": 30032768,
      "reboot_required": true,
      "description": "This package contains an update to PERC H355 RAID controller firmware",
      "revision_history": "Fixes\n=========\n  - Fix added to ignore the extra 3 bytes in the MCTP command with payload when wrong byte count field set in I2C header.\n  - Fixed drive firmware download metadata is not cleared until the last drive is finished updating.\n  - Fixed an issue where PL fault E40E observed with Switch attached topology. \n  - Fixed an issue where incorrect SATA Request Sense response for drive in active power condition by Clear the standby flag when start stop unit command is sent to SATA drive with start operation.\n  - Fixed an issue to log the link speed change event only if there is an actual change in speed.\n  - Fixed an issue to avoid starting a time for host IO in command block request when the controller is not operational yet.\n  - Fixed an issue where Predictive failure drive's DDF is not cleared after completing the copy back operation to global hot spare. \n  - Fixed an issue where Data Abort exception was observed during concurrent I/O operations, drive hot-plug, and UBM firmware update operations.\n  - Fixed an issue where Enabled column in storcli /cx/lnall show does not show disabled when the phy is marked unstable and disabled\n  - Fixed an issue where Firmware hits an exception, while converting JBODs to unconfigure state\n  - Fixed an issue where Controller fault 431E observed while running all phy off on test. \n  - Fixed an issue where SATA SMR Report Zone data not swapped correctly in some cases. \n  - Fixed an issue where Out of bound array access are restricted by additional conditional checks before accessing enclosure and drive related arrays.\n  - Fixed an issue where wrong patrol read resume event message after power cycle\n  - Added check condition checks and validation to prevent the buffer overflow during RDE drive enumeration.\n  - Fixed added when MCTP I2C OOB Communication Fails to Recover from a Malformed Packet.\n  - Added a fix for the Drive Security error that occurs when no drives are connected.\n  \nEnhancements/Tasks\n======================\n - Optimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "448ded191420b195668e21a896d8e278e90683ea41473b713cb91404b90354bf",
      "name": "Broadcom NetXtreme network device firmware (Dell), 23.8",
      "version": "23.81.6",
      "release_id": "6W3WV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-08T03:06:44Z",
      "released": "2026-09-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14991490M/2/Network_Firmware_6W3WV_WN64_23.81.6.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6W3WV",
      "size": 22772392,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for Broadcom NetXtreme devices.  This release should be used with the Broadcom 23.8 device drivers."
    },
    {
      "id": "23774ca68aa5836241bf13a7c01acb9cdca2109dc9f9dc8c9b25368cebf2b56a",
      "name": "Dell OS Driver Pack",
      "version": "26.08.02",
      "release_id": "H84RW",
      "category": "Drivers for OS Deployment",
      "category_slug": "drivers-for-os-deployment",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-08-14T09:48:57Z",
      "released": "2026-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14903130M/1/Drivers-for-OS-Deployment_Application_H84RW_WN64_26.08.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H84RW",
      "size": 54694632,
      "reboot_required": false,
      "description": "OS Driver Pack for PowerEdge 16G servers. This Driver Pack contains applicable storage, embedded LOM drivers and chipset drivers to support OS installation using the Dell Lifecycle Controller",
      "revision_history": "N/A"
    },
    {
      "id": "2cfb5d1f16ddc7672fb89251188bf188d61b25334440ba70289057a49c93cf2c",
      "name": "Intel NIC Family Version 25.0 Drivers for Windows 64-bit Operating Systems",
      "version": "25.0.0",
      "release_id": "J99NN",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-04T00:23:11Z",
      "released": "2026-08-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14855482M/1/Network_Driver_J99NN_WN64_25.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J99NN",
      "size": 53939904,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt."
    },
    {
      "id": "2fc9c4c2f6fba1fa1e47b6800081e8eb2ac2fa010c4276388723f045c8be6dfa",
      "name": "Dell EMC PowerEdge Express Flash NVMe AGN RI U.2 Gen5 Maintenance Firmware Release",
      "version": "1.3.0",
      "release_id": "HXTKM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-07-30T19:54:43Z",
      "released": "2026-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14844032M/1/Express-Flash-PCIe-SSD_Firmware_HXTKM_WN64_1.3.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HXTKM",
      "size": 32792912,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash NVMe AGN RI U.2 Gen5 Maintenance Firmware Release",
      "revision_history": "Fixes:\n1.  Sideband not accessible in panic state.\n2.  Fix to allow CR or SRIS at every PERST.\n3.  Write timeout observed during Sanitize with Block Erase.\n4.  Download/Activate doesn't complete when coupled with heavy sideband traffic.\n5.  Incorrect reference clock mode reporting after FLR.\n6.  Write command timeout due to garbage collection when out of free blocks.\n7.  Get/Set Features for OCP specific FID C4h successful for non-TCG configs.\n8.  Incorrect Response To Namespace Management Command Over MI.\n9.  PEC Error in NVMe Basic Management Command response.\n10. Resolved an SPDM attestation issue.\n\n\nEnhancements:\n\n1.  Use static endurance estimate: check the endurance estimate field of 09/C0 logpage.\n2.  Additional support added for firmware update for Dell PERC 12 and 13 controllers.\n3.  Support for 4K+8 format added.\n\nNote: Version 1.3.0 of PM1743/45 firmware is version locked due to the addition of the 4K+8 format option. Drives upgraded to 1.3.0 cannot be downgraded to previous versions of firmware."
    },
    {
      "id": "64c3b0521b620435ff6f16d6e050214f67b7fbe7f3a70d5205394e41833db3a9",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.8",
      "version": "23.81.0",
      "release_id": "RNT70",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:51:28Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843705M/1/Network_Driver_RNT70_WN64_23.81.0_238.1.170.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RNT70",
      "size": 14747512,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "e383c232a59d867730c67aff93fece1f8bb4e33d1f8f1d0795276821d80c6740",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.8 update.",
      "version": "38.11.70.00",
      "release_id": "X9DJG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:44:02Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843656M/2/Network_Driver_X9DJG_WN64_38.11.70.00_238.1.170.0_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9DJG",
      "size": 17265544,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "7a614f2dd02a71f7264337b85eb55d6adcb4d0302e69a8d71ab2c7eae29d15bf",
      "name": "PERC H755 RAID Controller firmware version 52.30.0-6753",
      "version": "52.30.0-6753",
      "release_id": "N6C86",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-06-02T16:27:30Z",
      "released": "2026-06-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14615957M/4/SAS-RAID_Firmware_N6C86_WN64_52.30.0-6753_A11_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N6C86",
      "size": 32673752,
      "reboot_required": true,
      "description": "PERC H755 RAID Controller firmware version 52.30.0-6753",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions, including Single Bit Errors (SBE) and Multi Bit Errors (MBE).\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown to power off the system, followed by a power on to enable the new memory settings.\nA warm reboot will NOT activate the updated settings.\nIf iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required."
    },
    {
      "id": "be2552182a26eb88759d7217cc5aefc2cd96994a7322cfad3004048d11f48723",
      "name": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "version": "1.0.2",
      "release_id": "HN0CY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-19T21:48:29Z",
      "released": "2026-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568517M/1/Express-Flash-PCIe-SSD_Firmware_HN0CY_WN64_1.0.2_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN0CY",
      "size": 29331112,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "revision_history": "Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software)."
    },
    {
      "id": "f0477d83411396c5aa41dc093b6f87c193db3f8a49b4276a1d829a96500bfa3e",
      "name": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.2",
      "release_id": "17R29",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-05-12T10:07:15Z",
      "released": "2026-05-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14538090M/1/Express-Flash-PCIe-SSD_Firmware_17R29_WN64_2.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17R29",
      "size": 27203048,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Upon detecting SMBDAT is stuck in low state, a bus clear is performed to release the low state.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "78c2385f78e01efa51a8798695530f7a9d445ab7b40872bfb2d691b7e9e3b663",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.5",
      "release_id": "KRHCN",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-05-06T15:41:31Z",
      "released": "2026-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14515537M/1/Express-Flash-PCIe-SSD_Firmware_KRHCN_WN64_2.0.5_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KRHCN",
      "size": 27415688,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release"
    },
    {
      "id": "60553b31a0c7840eea26725f7b5326f9b56066af9311d5db5722d384d7880959",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "version": "3.0.6",
      "release_id": "7H42K",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-05-06T15:25:06Z",
      "released": "2026-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14515495M/1/Express-Flash-PCIe-SSD_Firmware_7H42K_WN64_3.0.6_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7H42K",
      "size": 27628736,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release"
    },
    {
      "id": "efe2365628ce7b7706b69e3c6031e469867813c8497252d8d3d310be130ea00e",
      "name": "BOSS-N1 Modular ET Firmware",
      "version": "2.1.13.2038",
      "release_id": "YVYW4",
      "category": "BOSS",
      "category_slug": "boss",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-04T06:36:54Z",
      "released": "2026-04-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14503502M/3/BOSS_Firmware_YVYW4_WN64_2.1.13.2038_A07_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YVYW4",
      "size": 23270488,
      "reboot_required": true,
      "description": "BOSS-N1 Modular ET Package version 2.1.13.2038"
    },
    {
      "id": "9908629a3c6dc68fa7bd50152775a1b55d88d11e66dbd615cc0ee12ee6f32e5c",
      "name": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "HJ15N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-07T10:29:04Z",
      "released": "2025-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14393389M/1/Express-Flash-PCIe-SSD_Firmware_HJ15N_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HJ15N",
      "size": 28267144,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "revision_history": "Fixes:\nN/A - Initial Release\n\nEnhancements:\nN/A - Initial Release"
    },
    {
      "id": "d014e87f2c31947d6adbb5f0b7e6decf7c26d75d355467c5852dbf4cb5e3deac",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 SED Firmware Maintenance Release (MR3)",
      "version": "2.3.1",
      "release_id": "GYJ0D",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-03-11T23:46:32Z",
      "released": "2026-02-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14291594M/1/Express-Flash-PCIe-SSD_Firmware_GYJ0D_WN64_2.3.1_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GYJ0D",
      "size": 27170384,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 SED Firmware Maintenance Release (MR3)",
      "revision_history": "Fixes:  \n\n1. Improved the firmware to ensure internal PCIe register access is done according to the specification.\n2. Updated the firmware to add SCL detection/protection\n3. Improved firmware to detect the noise on power rail.\n4. Improved firmware to add detection/protection for incomplete Host-Initiated Data Transfer\n5. Improved firmware to add detection/protection for drive Initialization with Poor PCIe Signal Integrity\n6. Improved firmware to add detection and initiate rest/recovery operation to the power management controller upon power on.\n7. Updated the firmware to prevent the deadlock scenario while extended Host Idle Time (no SSD device I/O)\n8. Updated the firmware to Enable PCIe relaxed ordering\n\nEnhancements:  \nN/A"
    },
    {
      "id": "832f358867a87dbab42fc379e286da1d8bd7b8fd87d614862be22df1da90058d",
      "name": "Hynix SE5130 DG02 Firmware for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N",
      "version": "DG02",
      "release_id": "17C3M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-03-09T14:43:52Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14279570M/1/Serial-ATA_Firmware_17C3M_WN64_DG02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17C3M",
      "size": 25675424,
      "reboot_required": true,
      "description": "This is the initial firmware release of HYNIX, SE5130, DG02 for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N.",
      "revision_history": "Fixes:\n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "2576d421636e87b519086721087196201ac74ebd37755dce4f70eb579e503d8d",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release Maintenance Firmware",
      "version": "1.3.1",
      "release_id": "N78NP",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-03T19:47:31Z",
      "released": "2026-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14259015M/1/Express-Flash-PCIe-SSD_Firmware_N78NP_WN64_1.3.1_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N78NP",
      "size": 27170488,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release - Maintenance Firmware",
      "revision_history": "Fixes:  \n\n1. Improved the firmware to ensure internal PCIe register access is done according to the specification.\n2. Updated the firmware to add SCL detection/protection\n3. Improved firmware to detect the noise on power rail.\n4. Improved firmware to add detection/protection for incomplete Host-Initiated Data Transfer\n5. Improved firmware to add detection/protection for drive Initialization with Poor PCIe Signal Integrity\n6. Improved firmware to add detection and initiate rest/recovery operation to the power management controller upon power on.\n7. Updated the firmware to prevent the deadlock scenario while extended Host Idle Time (no SSD device I/O)\n8. Updated the firmware to Enable PCIe relaxed ordering\n\nEnhancements:  \nN/A"
    },
    {
      "id": "c9b41b21cbbcb00bd5365d004fa23c5cfc5886c7562f50846076b5e00df72bcf",
      "name": "Intel NIC Family Version 25.0.0 Firmware for Intel I350 and X550 Adapters",
      "version": "25.0.4",
      "release_id": "HMDDR",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-02-12T15:08:34Z",
      "released": "2026-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14205749M/2/Network_Firmware_HMDDR_WN64_25.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HMDDR",
      "size": 23253664,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.X on Intel I350 and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.X on Intel I350 and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "f90cc54712c96fa90b3d686e1a364c9add6a13f9467ab55c5b33f3095b0ab102",
      "name": "Intel NIC Family Version 25.0.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "25.0.4",
      "release_id": "PJDHV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-02-12T14:50:50Z",
      "released": "2026-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14205977M/2/Network_Firmware_PJDHV_WN64_25.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PJDHV",
      "size": 46329512,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "See the fw_release_x710.txt file for more information."
    },
    {
      "id": "8e9c30fc9b9ba6c222b03354fbe3512accdaedd94a1db3099eafbe926f2f3bf7",
      "name": "Intel NIC Family Version 25.0.0 Firmware for Intel E810 Adapters and Intel E823 LOM",
      "version": "25.0.4",
      "release_id": "FCG2V",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-02-12T14:41:44Z",
      "released": "2026-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14206113M/1/Network_Firmware_FCG2V_WN64_25.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FCG2V",
      "size": 72664168,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.x on Intel E810 adapters and Intel E823 LOM. This release provides continued code optimization to improve performance.",
      "revision_history": "See fw_release_e810_e823.txt for more information."
    },
    {
      "id": "58e394bb0219f32769b3c7c4911b1e094710048d3d16d092fe19ba0c8ded1e36",
      "name": "Dell 64 Bit uEFI Diagnostics, version 4303",
      "version": "4303A52",
      "release_id": "94KRT",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-01-14T21:20:10Z",
      "released": "2025-11-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14086682M/1/Diagnostics_Application_94KRT_WN64_4303A52_4303.52.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=94KRT",
      "size": 19092400,
      "reboot_required": false,
      "description": "Dell Diagnostics is designed to verify the proper operation of the hardware installed in your system outside of a high-level operating system environment. The files in this group can be used to update these diagnostics on a system with a Lifecycle Controller.",
      "revision_history": "This release contains minor bug fixes and enhancements."
    },
    {
      "id": "11627fb16dae8be6533ae44611508823df7dfc7d630b3da2e026012a1e143926",
      "name": "Dell Express Flash NVMe PCIe SSD 7600 U.2 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "VJXKC",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-09T04:07:55Z",
      "released": "2026-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14057449M/1/Express-Flash-PCIe-SSD_Firmware_VJXKC_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJXKC",
      "size": 30405520,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7600 U.2 ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any Linux OS. Either use Windows, or iDRAC for FW update. - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "cca5695e4a8e61074fdc1de3a322725393df6e48f8498fa5f2dd6e2c301186f7",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "71KRG",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-12-16T18:48:47Z",
      "released": "2025-09-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13990425M/1/Express-Flash-PCIe-SSD_Firmware_71KRG_WN64_1.2.0_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=71KRG",
      "size": 29639544,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Improvements to drive internal logging.\n2. Improvements to SMART logging and notification.\n3. Resolved sideband firmware download issue.\n\nEnhancements:\n\n1. Additional support added for firmware update for Dell 17th generation servers.\n2. Additional support added for firmware update for Dell PERC 12 and 13 controllers."
    },
    {
      "id": "45702dc92959e5bb5ad182958bf5511ee357e045afd9ff6a07da3678ffbe525e",
      "name": "Mellanox ConnectX-6 LX Ethernet Adapter Firmware",
      "version": "26.40.1000",
      "release_id": "633VJ",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-12-03T13:31:34Z",
      "released": "2025-11-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13939058M/1/Network_Firmware_633VJ_WN64_26.40.1000_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=633VJ",
      "size": 40892520,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-6 LX Adapters"
    },
    {
      "id": "f5bfd9963a31ba63314fe7c5b7136b0192d0e64945355d999a0c5bb21ce10910",
      "name": "Mellanox ConnectX-6 DX Ethernet Adapter Firmware",
      "version": "22.40.1000",
      "release_id": "CNC6W",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-26T03:33:03Z",
      "released": "2025-11-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13911831M/1/Network_Firmware_CNC6W_WN64_22.40.1000_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CNC6W",
      "size": 41383744,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-6 DX Adapters"
    },
    {
      "id": "dbdfbff4fda3b33a0f47c4f2c9593f17f3ce0e05b9698b3ff06a66b44465d1ae",
      "name": "Hynix SE5110 ISE RI DZ04 Firmware for model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N",
      "version": "DZ04",
      "release_id": "HFTMG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-11-12T10:51:19Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13855285M/1/Serial-ATA_Firmware_HFTMG_WN64_DZ04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HFTMG",
      "size": 26870384,
      "reboot_required": true,
      "description": "This release contains initial firmware DZ04 for Hynix SE5110 ISE. Model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N.",
      "revision_history": "Fixes: \n\nFix1: Add a sequence to clear the \"\"health monitoring done bit\"\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while."
    },
    {
      "id": "084c4c862eb04bca11886df3cc480d08a1b762a058189ccf46755ff6564037c4",
      "name": "Dell Express Flash NVMe P5520/P5620 PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "12W9R",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-10-31T17:04:04Z",
      "released": "2025-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13807766M/1/Express-Flash-PCIe-SSD_Firmware_12W9R_WN64_1.5.0_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=12W9R",
      "size": 27905664,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P5520/5620 PCIe SSD Firmware Release MR4"
    },
    {
      "id": "f36f95265ef3b8adc3b30dcdd865d0c709ff33479e42f252db81228610a4c422",
      "name": "Non-Expander Storage Backplane Firmware",
      "version": "7.16",
      "release_id": "2YC1M",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-10-10T17:58:27Z",
      "released": "2023-04-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13715567M/4/Firmware_2YC1M_WN64_7.16_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2YC1M",
      "size": 22767200,
      "reboot_required": false,
      "description": "Passive SEP Backplane Firmware for 16th Generation PowerEdge MX and select XR Systems",
      "revision_history": "Firmware 7.16\n\nFixes:\n- None\n\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\n\nChange History:\n\nFirmware 7.10\nFixes:\n- Addressed a potential backplane issue where some slot descriptor values are not correctly initialized which could prevent the storage controller and/or hard drives from being displayed in the iDRAC Storage inventory.\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes."
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "03de1d08414a2b511614268e4a3d7ddf38fb318e34a27f7dec7fcf35c69497f2",
      "name": "Dell Express Flash NVMe PCIe SSD CM6 FIPS Maintenance Firmware Release",
      "version": "3.1.7",
      "release_id": "WJD95",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-10T05:56:19Z",
      "released": "2024-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11856439M/3/Express-Flash-PCIe-SSD_Firmware_WJD95_WN64_3.1.7_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WJD95",
      "size": 28731088,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM6 FIPS Firmware Maintenance Release",
      "revision_history": "N/A"
    },
    {
      "id": "95871e8ff8c0f6e426c85f58cc37ef3e8226eaf06295f90f7481274b542f39b1",
      "name": "Dell Datacenter NVMe RI AG OPAL",
      "version": "1.0.0",
      "release_id": "D88MM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-08-20T03:26:04Z",
      "released": "2024-05-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674337M/3/Express-Flash-PCIe-SSD_Firmware_D88MM_WN64_1.0.0_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D88MM",
      "size": 31371800,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG OPAL",
      "revision_history": "Initial release with addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "bc20d7bbdd73425a126be1aa9a9baaf4273de370b22b151f7af3fa187cb42b4a",
      "name": "Dell Express Flash NVMe PCIe SSD CM6 Maintenance Firmware Release",
      "version": "2.2.2",
      "release_id": "GMM6V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-20T03:23:06Z",
      "released": "2024-07-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11805909M/3/Express-Flash-PCIe-SSD_Firmware_GMM6V_WN64_2.2.2_A08_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GMM6V",
      "size": 28521944,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM6 Firmware Maintenance Release"
    },
    {
      "id": "c4bf141c6378349d3febc74b35f5a3024900e88e5afeb3a1a67d0c554248998e",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.1 update.",
      "version": "23.11.16.21",
      "release_id": "8YWJY",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-20T03:19:10Z",
      "released": "2024-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12155596M/4/Network_Driver_8YWJY_WN64_23.11.16.21_231.1.162.1_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8YWJY",
      "size": 14278288,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- Stop 0x133 blue screen on Windows Azure Stack HCI.\n\nEnhancements:\n- none."
    },
    {
      "id": "d6003018a24a73dfb6c4e3c377f37f0036794857d905ae5c92c8a53d0556e33d",
      "name": "Samsung PM1653a 24GBP\u0026apos;s SAS SSDs for DSB1 firmware for models MZILG1T9HFJAAD3, MZILG3T8HFLTAD3, MZILG7T6HBLCAD3, MZILG15THBLFAD3, MZILG30THBLFAD3.",
      "version": "DSB1",
      "release_id": "862D9",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T12:27:24Z",
      "released": "2025-06-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13525355M/1/SAS-Drive_Firmware_862D9_WN64_DSB1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=862D9",
      "size": 23808800,
      "reboot_required": true,
      "description": "This initial release of Samsung PM1653a 24 GBP's SAS SSDs for DSB1 firmware is for models MZILG1T9HFJAAD3, MZILG3T8HFLTAD3, MZILG7T6HBLCAD3, MZILG15THBLFAD3, MZILG30THBLFAD3.",
      "revision_history": "Fix:\n\n- Initial release."
    },
    {
      "id": "5c76c7500116556002ebf8d0adf72925359f1698d7233524896f79ba26a107c8",
      "name": "Dell Datacenter NVMe RI AG ISE",
      "version": "1.0.0",
      "release_id": "0H9DD",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-08-19T09:53:24Z",
      "released": "2024-05-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674254M/3/Express-Flash-PCIe-SSD_Firmware_0H9DD_WN64_1.0.0_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0H9DD",
      "size": 31033848,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE",
      "revision_history": "Initial release with addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "b3756f56e76fb6fdf6d53d9bc0bb41fa37aaf9ec858ba959301334044cd538e7",
      "name": "DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR",
      "version": "DL7C",
      "release_id": "VJPKG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-08-19T07:07:49Z",
      "released": "2025-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12600340M/4/Serial-ATA_Firmware_VJPKG_WN64_DL7C_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJPKG",
      "size": 22988728,
      "reboot_required": false,
      "description": "This is a firmware release for DELLSLDM Youngsville-RR  DL7C firmware for Model number(s) SSDSC2KB240GZR, SSDSC2KB480GZR, SSDSC2KB960GZR, SSDSC2KB019TZR, SSDSC2KB038TZR, SSDSC2KB076TZR, SSDSCKKB240GZR, SSDSCKKB480GZR,SSDSC2KG480GZR, SSDSC2KG960GZR, SSDSC2KG019TZR, SSDSC2KG038TZR",
      "revision_history": "Issue: During a warm Reboot the YVRR drive may intermittently disappear when connected to the PERC H965i\nFix: DL7C FW now addresses this issue\nIssue: PLI capacitor charge flag not set leads drive to enter disable logical mode\nFix: DL7C FW now addresses this issue"
    },
    {
      "id": "6b8fe0e8d91ff1271a42ada59a153ff6182e02d9af7e3d6ab2ede54b99a9287d",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.0",
      "version": "23.00.0",
      "release_id": "GJ9N4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-14T05:26:36Z",
      "released": "2024-09-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11901569M/3/Network_Driver_GJ9N4_WN64_23.00.0_230.1.116.0_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GJ9N4",
      "size": 14389968,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- BCM5719 missing Jumbo MTU and LSO options in Advanced Properties.\n\nEnhancements:\n- Add support for Windows Server 2025."
    },
    {
      "id": "dc8129f8e809b3ef0059b5776f5811a8bf3f8bfb75c0c5a365a994b47bd55d25",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.0 update.",
      "version": "23.01.11.60",
      "release_id": "FPMGT",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-13T09:16:08Z",
      "released": "2024-09-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11901574M/3/Network_Driver_FPMGT_WN64_23.01.11.60_230.1.116.0_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FPMGT",
      "size": 14640336,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for Windows Server 2025."
    },
    {
      "id": "d7118a4011a988e2e951915d1cc298925ca524ddf11d30cbbcda0b4011e70320",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.4.0",
      "release_id": "TVCWT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-07-11T04:31:50Z",
      "released": "2025-07-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13369867M/1/Express-Flash-PCIe-SSD_Firmware_TVCWT_WN64_1.4.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TVCWT",
      "size": 29064896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo be added"
    },
    {
      "id": "94586f99bddb6d07e51ebf78479fa5de5fb353777dec7e7bb0b73c704b3c21bf",
      "name": "Dell Datacenter NVME RI AGN ISE",
      "version": "1.1.1",
      "release_id": "XMFKX",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:50:32Z",
      "released": "2024-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12037085M/2/Express-Flash-PCIe-SSD_Firmware_XMFKX_WN64_1.1.1_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XMFKX",
      "size": 30415680,
      "reboot_required": false,
      "description": "Dell Datacenter NVME RI AGN ISE",
      "revision_history": "Fixes:\n\n1. Updated DUP framework for 17G server platforms."
    },
    {
      "id": "72edf6a3bd3e7561ff46a85ae83b2753b40bcd7368e4884558a1de18497c0740",
      "name": "Dell Express Flash NVMe PCIe SSD CD8 U.2 OPAL Firmware Maintenance Release",
      "version": "1.0.1",
      "release_id": "11TRD",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T10:21:01Z",
      "released": "2025-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12428385M/2/Express-Flash-PCIe-SSD_Firmware_11TRD_WN64_1.0.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=11TRD",
      "size": 29787784,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8 U.2 OPAL Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. For PCI Information such as PCI Vendor ID other than BDF, FW also keeps their value. So, fixed to respond the value directly from FW instead of getting them from HW.\n2. Instead of clearing the Abort flag at the beginning of the response data retransfer processing task, modify it to clear the Abort flag when data transfer after retransfer becomes possible.\n3. Fix the bug that write index of SMBus ring buffer was out of sync.\n4. Max payload size is immediately reflected in the internal register when the value is changed.\n5. Wait for transition from Recovery when VDM packet forwarding is completed.\n6. Fixed to resume Write process after NAND Timeout recovery process.\n7. Set OACS bit10 to 1 to remove support of Lockdown on the in-band interface.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "83e5394bba0bd6c0a1f76806981be2e474474860d11f297bdfff3dd68c4705f6",
      "name": "EGS Chipset Driver_10.1.19928.8615",
      "version": "10.1.19928.8615",
      "release_id": "R40PW",
      "category": "Chipset",
      "category_slug": "chipset",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-05-07T16:03:56Z",
      "released": "2025-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12931889M/3/Chipset_Driver_R40PW_WN64_10.1.19928.8615_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R40PW",
      "size": 8981672,
      "reboot_required": true,
      "description": "EGS Chipset Drivers_10.1.19928.8615\nAdditional manual installation is required for QAT device to support WS2022 / WS2025/ signed driver",
      "revision_history": "Fixes:\n- N/A\n\nEnhancements:\n- Add support for 24H2 for some platforms, with provisions for future support on additional platforms"
    },
    {
      "id": "0ec4a72763c6f617356a0e2ee5e7e3aad191109ec75324d8f0202fff4986bbaf",
      "name": "Mellanox Windows 64-bit Server OS drivers for Mellanox ConnectX-4 Lx, ConnectX-5, ConnectX-6 and ConnectX-7 Ethernet adapters",
      "version": "25.1",
      "release_id": "3G71F",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-04-23T17:03:08Z",
      "released": "2025-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13036121M/1/Network_Driver_3G71F_WN64_25.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3G71F",
      "size": 213767824,
      "reboot_required": false,
      "description": "This package provides the Windows 64-bit drivers for Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, and ConnectX-7 Ethernet Adapters and is supported on Dell EMC PowerEdge servers with the following operating systems: Windows Server 2019 and Windows Server 2022"
    },
    {
      "id": "736e89923bb3c28df28dc52a33909657ef3c7f17816fa6be7cd3ade0082728b9",
      "name": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "version": "C40E",
      "release_id": "57MM2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:28:10Z",
      "released": "2024-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374876M/2/SAS-Drive_Firmware_57MM2_WN64_C40E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=57MM2",
      "size": 24391360,
      "reboot_required": false,
      "description": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "revision_history": "Fixes: \n\n- Fix1: FW is fixed to execute the flush process and Flash Memory parameter modification process exclusively.\n- Fix2: Fixed that the host I/O proceed by the skip of GC if the validity determination process of user data takes time.\n- Fix3: Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "2d586d18bf6bfd668a4b76e782765a56bb78bffe1a219c60613e9b1ae474dbde",
      "name": "Model numbers are KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8, KPM7XRUG960G, KPM7XVUG800G, KPM7XMUG400G, KPM7XMUG800G, KPM7XMUG1T60",
      "version": "C10E",
      "release_id": "T21WT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:11:55Z",
      "released": "2024-06-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374981M/2/SAS-Drive_Firmware_T21WT_WN64_C10E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T21WT",
      "size": 24314272,
      "reboot_required": false,
      "description": "This release contains firmware version C10E for Kioxia PM7 24Gbps SAS 2.5 (10WPD, 1WPD, 3WPD).\nModel numbers are KPM7XMUG400G, KPM7XMUG800G, and KPM7XMUG1T60,\nKPM7XVUG800G, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8,KPM7XRUG960G, KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3.",
      "revision_history": "Fix:\n\n-  Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "0776b5d687d3fbafca1eb2f20fa128d1b4ec7423dcc2fefe3e9f3387ab95092f",
      "name": "Kioxia BA48 FW for PM6 drives for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "version": "BA48",
      "release_id": "NGPR2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T05:55:37Z",
      "released": "2022-09-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08764563M/4/SAS-Drive_Firmware_NGPR2_WN64_BA48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NGPR2",
      "size": 24171504,
      "reboot_required": false,
      "description": "Kioxia PM6 BA48 FW for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "revision_history": "Fixes:\nInitial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "da85579aa702b2b4706a4585289b3365530f2b08daaa68c78b9a2fca56bcd394",
      "name": "Hynix 1.2.1 FW for PE9030 NVMEe drive program for model number HFS800GDJ8X167N",
      "version": "1.2.1",
      "release_id": "9GH86",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-08T10:44:59Z",
      "released": "2025-04-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12967278M/1/Express-Flash-PCIe-SSD_Firmware_9GH86_WN64_1.2.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9GH86",
      "size": 19658776,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.2.0 for Hynix PE9030 NVMe SSD drive program for model number HFS800GDJ8X167N",
      "revision_history": "Fixes:\n\nFixes the DCTm layer that was introduced in 1.2.'0. Pauses MCTP for Error responsing Admin command (ex. Invalid Opcode, Prohibited Opcode..) when CIAP==1.\nChanged not to block MI command in reset service blocker.\nFix to treat FTL fail of, unattached address area, during DST as DSTR:6\nFixed smbus interrupt error case\nAdd NSSR to PanicResetAction\nSet PEL for control primitive resume with invalid param for CSI\n\"First packet received in multi packet\nMCTP Control message received with same tag.\nFirst message discard, but slot state (MI context) not clear.\"\nset NSSRO bit after panic reset\nClear MI GetState ErrorState Bits managed on HADM side when MCTP Endpoint reset.\nCheck DOFST field of MI admin commands before processing.\nSmart::updateControllerBusyTime bug fix\nreset number of queues during nvme reset\nAssert occurs during SPL in Panic Recovery\nFix DELL Incorrect TLA and ADellEMCUI default values\nPCIe correctable receiver error during NSSR"
    },
    {
      "id": "2142620e2c8d50ab1cb18380fc3fde53962851f2adaa2310acaf43d8362b33f5",
      "name": "Hynix 1.2.1 FW for PE9010 NVMe drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "version": "1.2.1",
      "release_id": "8X8YR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-08T07:02:51Z",
      "released": "2025-04-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12965378M/1/Express-Flash-PCIe-SSD_Firmware_8X8YR_WN64_1.2.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8X8YR",
      "size": 23487200,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.2.0 for Hynix PE9010 NVMe SSD drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, and HFS480GDJ8X167N.",
      "revision_history": "Fixes:\n\nFixes the DCTm layer that was introduced in 1.2.0 '  Pause MCTP for Error responsing Admin command (ex. Invalid Opcode, Prohibited Opcode..) when CIAP==1.\nChanged not to block MI command in reset service blocker.\nFix to treat FTL fail of, unattached address area, during DST as DSTR:6\nFixed smbus interrupt error case\nAdd NSSR to PanicResetAction\nSet PEL for control primitive resume with invalid param for CSI\n\"First packet received in multi packet\nMCTP Control message received with same tag.\nFirst message discard, but slot state (MI context) not clear.\"\nset NSSRO bit after panic reset\nClear MI GetState ErrorState Bits managed on HADM side when MCTP Endpoint reset.\nCheck DOFST field of MI admin commands before processing.\nSmart::updateControllerBusyTime bug fix\nreset number of queues during nvme reset\nAssert occurs during SPL in Panic Recovery\nFix DELL Incorrect TLA and ADellEMCUI default values\nPCIe correctable receiver error during NSSR"
    },
    {
      "id": "08e52e53cd3535af1afa946454750977fcdc1dc6d0aa894d66fd2e97d3df5bf4",
      "name": "Windows Server 2025 Driver for PERC Controllers",
      "version": "7.730.02.00",
      "release_id": "KFJHK",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-04-01T19:31:25Z",
      "released": "2024-10-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12935221M/1/SAS-RAID_Driver_KFJHK_WN64_7.730.02.00_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KFJHK",
      "size": 14535624,
      "reboot_required": true,
      "description": "This is the initial release of the Windows 2025 Server driver to 7.730.02.00 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers.",
      "revision_history": "Fixed MPI registers read may return value of 0 in SecureMode\nFixed firmware update error"
    },
    {
      "id": "f9dd1ef52f1a48841d176022bd9199fbfc02f577a7b3751f755be38f5bcd6845",
      "name": "Windows Server 2025 Driver 2.61.74.00  for HBA11 Controllers",
      "version": "2.61.74.00",
      "release_id": "HDH8G",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-18T07:37:24Z",
      "released": "2025-03-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12873405M/1/SAS-Non-RAID_Driver_HDH8G_WN64_2.61.74.00_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HDH8G",
      "size": 14613432,
      "reboot_required": true,
      "description": "This release updates Windows 2025 Server driver to 2.61.74.00 for HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter/MX/MM/MMLP Controllers."
    },
    {
      "id": "b355fdf544e9926c98f922251403039b114b84909c30586205daffdc4062a2e0",
      "name": "Windows Server 2022 Driver 2.61.74.00 for HBA11 Controllers",
      "version": "2.61.74.00",
      "release_id": "R31NP",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-18T06:28:20Z",
      "released": "2025-03-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12872713M/1/SAS-Non-RAID_Driver_R31NP_WN64_2.61.74.00_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R31NP",
      "size": 14612344,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver to 2.61.74.00 for HBA345 Adapter/Front, HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter/MX/MM/MMLP Controllers."
    },
    {
      "id": "b07ed9c323272e57a5d659a5f3714da6c411ffb52d39147508f2d85ab5003234",
      "name": "Dell HBA355e Adapter Controller firmware version 33.15.00.00",
      "version": "33.15.00.00",
      "release_id": "C1R6T",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-03-17T11:46:27Z",
      "released": "2025-03-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12868772M/1/SAS-Non-RAID_Firmware_C1R6T_WN64_33.15.00.00_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C1R6T",
      "size": 24428608,
      "reboot_required": true,
      "description": "Dell HBA355e Adapter Controller firmware version 33.15.00.00"
    },
    {
      "id": "534639a1936e29054ce8dd96e0e452743334523acd505cf6efb4f138179a26de",
      "name": "Dell HBA355i Front/Adapter HBA350i MX Controllers firmware version 33.15.00.00",
      "version": "33.15.00.00",
      "release_id": "CG0P9",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-03-17T11:31:59Z",
      "released": "2025-03-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12868698M/1/SAS-Non-RAID_Firmware_CG0P9_WN64_33.15.00.00_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CG0P9",
      "size": 27063496,
      "reboot_required": true,
      "description": "Dell HBA355i Front/Adapter HBA350i MX Controllers firmware version 33.15.00.00"
    },
    {
      "id": "90185f8e0eb9a36b0268f12c76033b8595571088acd45cdc75763cf19f7ffb4b",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.2",
      "version": "23.21.5",
      "release_id": "YWMRX",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-14T01:06:32Z",
      "released": "2025-01-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12577197M/2/Network_Driver_YWMRX_WN64_23.21.5_232.1.133.2_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YWMRX",
      "size": 13975856,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Support for new Dell server models."
    },
    {
      "id": "8805f93f162a5e9a7282553f3a2eb98d8cfd822f43e29e41219e7f999c02fac5",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.2 update.",
      "version": "23.21.13.32",
      "release_id": "G535X",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-14T01:03:16Z",
      "released": "2025-01-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12577171M/2/Network_Driver_G535X_WN64_23.21.13.32_232.1.133.2_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G535X",
      "size": 14210264,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver."
    },
    {
      "id": "3b9eebdef5e20a0aa3cd3e19f026a3b083e6922d57fb761a68e1283c30bae6a4",
      "name": "Samsung PM893 SATA SSDs for HJ58 firmware for models MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3.",
      "version": "HJ58",
      "release_id": "7YCK2",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-29T05:01:43Z",
      "released": "2024-02-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11250216M/7/Serial-ATA_Firmware_7YCK2_WN64_HJ58_A00_06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7YCK2",
      "size": 13849624,
      "reboot_required": true,
      "description": "This release contains firmware version Samsung HJ58 for model number(s) MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3.",
      "revision_history": "Addresses an issue when Queued Trim commands are inter-mixed with IO commands resulting in a possible Command Timeout or other unexpected system behaviors.\nNOTE: Update will take effect upon next power cycle"
    },
    {
      "id": "954979d853d6454beb7013a071d89b5b84a1de1aa3eaeebd76cbb6ce3e5ef263",
      "name": "Dell EC MICRON 7400 NVMe M.2 RI FW 1.6.0 MTFDKBA800TFC,MTFDKBA480TDZ,MTFDKBG1T9TDZ,MTFDKBA960TDZ,MTFDKBG3T8TDZ,MTFDKBA960TDZ,MTFDKBA480TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG960TDZ,MTFDKBG3T8TDZ",
      "version": "1.6.0",
      "release_id": "N71F4",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-28T11:03:56Z",
      "released": "2024-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12035394M/1/Express-Flash-PCIe-SSD_Firmware_N71F4_WN64_1.6.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N71F4",
      "size": 7739616,
      "reboot_required": false,
      "description": "Dell EC MICRON 7400 NVMe M.2 RI FW 1.6.0 MTFDKBA800TFC,MTFDKBA480TDZ,MTFDKBG1T9TDZ,MTFDKBA960TDZ,MTFDKBG3T8TDZ,MTFDKBA960TDZ,MTFDKBA480TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG960TDZ,MTFDKBG3T8TDZ",
      "revision_history": "Fixes: \n\n- Multiple FW fixes and enhancements."
    },
    {
      "id": "2e142fa2b3bba65e6701761803eb6b88963468bee9960a715304452f1a20de58",
      "name": "Intel NIC Family Version 23.0.0 Firmware for Intel I350 and X550 Adapters",
      "version": "23.0.8",
      "release_id": "WVM0R",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-08T02:04:05Z",
      "released": "2024-07-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890380M/3/Network_Firmware_WVM0R_WN64_23.0.8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WVM0R",
      "size": 13964792,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 23.0.X on Intel I350, I354 and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "Fixes\n=====\n   - Fixed problem where updating I350 NICs would not preserve the Virtualization Mode and would reset \n     the Virtualization Mode to the factory default of \"None\". {266366}\n   - Fixed an issue where Intel i350-based NICs would display invalid boot options in Boot Manager in the \n     legacy boot mode. {277961}\n     \nKnown Issues\n============\n   - Devices based on the Intel(R) Ethernet I350 controller do not support the LLDP Discovery feature\n     with Dell iDRAC.\n   - Received packets with incorrect length can generate alarms in VMware ESXi 7.0U2 and later.\n     These alarms can be ignored. Please reference this VMware KB article for more details: \n     https://kb.vmware.com/s/article/83627. {229496, 232005}"
    },
    {
      "id": "a3327e1940b3fe3b81e47fa9d3bb7aeffd6956b5f4ee06f4a9f14c97f3c83a19",
      "name": "Samsung PM1653 drives for DSG9 FW for model numbers MZILG960HCHQAD3, MZILG1T9HCJRAD3, MZILG3T8HCLSAD3, MZILG7T6HBLAAD3 and MZILG15THBLAAD3",
      "version": "DSG9",
      "release_id": "3MV58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T17:20:50Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11939710M/1/SAS-Drive_Firmware_3MV58_WN64_DSG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3MV58",
      "size": 13264392,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count acuracy and drive temperature reporting during format operations. Firmware version DSG9 for Samsung PM1653 drives. Vendor model numbers MZILG960HCHQ-0AD3, MZILG1T9HCJR-0AD3, MZILG3T8HCLS-0AD3, MZILG7T6HBLA-0AD3, and MZILG15THBLA-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "e15c231399536e80009d372366b4e72a4c66dedf951ad1fa78d1309ab3e37961",
      "name": "Samsung PM1655 drives for FW DWG9 for model numbers MZILG800HCHQAD3, MZILG1T6HCJRAD3 and MZILG3T2HCLSAD3",
      "version": "DWG9",
      "release_id": "7MTXM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T08:00:58Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11937657M/1/SAS-Drive_Firmware_7MTXM_WN64_DWG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7MTXM",
      "size": 13261200,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count accuracy and drive temperature reporting during format operations. Firmware version DWG9 for Samsung PM1655 drives. Vendor model numbers MZILG800HCHQ-0AD3, MZILG1T6HCJR-0AD3, and MZILG3T2HCLS-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "6dffa0fa05d98ecf5dd6f683737e3ab3d4e113f263fe4ec62004af5ecf3268e8",
      "name": "Intel NIC Family Version 23.0.0 Drivers for Windows 64-bit Operating Systems",
      "version": "23.0.0",
      "release_id": "6JHVK",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-07-19T15:27:45Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890492M/1/Network_Driver_6JHVK_WN64_23.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6JHVK",
      "size": 42776640,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "See readme.txt for more info."
    },
    {
      "id": "38ce666b414aeb76c917c135ec2409621ef9a2b5e2868cf51c89690d8b8d8768",
      "name": "Samsung PM897 SATA SSDs for HH58 firmware for models MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "version": "HH58",
      "release_id": "MX4DP",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-07-19T12:36:25Z",
      "released": "2024-02-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11184068M/4/Serial-ATA_Firmware_MX4DP_WN64_HH58_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MX4DP",
      "size": 13848528,
      "reboot_required": true,
      "description": "This release contains firmware version Samsung HH58 for model number(s) MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "revision_history": "Addresses an issue when Queued Trim commands are inter-mixed with IO commands resulting in a possible Command Timeout or other unexpected system behaviors.\nNOTE: Update will take effect upon next power cycle"
    },
    {
      "id": "7be90932a9eca915194db12b4b54c6e2d1dfaf50ecc4c79c27b1761682ea45d0",
      "name": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "version": "2.5.0",
      "release_id": "4P5K1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-07-03T13:05:39Z",
      "released": "2024-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11804735M/1/Express-Flash-PCIe-SSD_Firmware_4P5K1_WN64_2.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4P5K1",
      "size": 7724464,
      "reboot_required": false,
      "description": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "revision_history": "Fixes:\n\n- FW introduces multiple fixes and enhancements."
    },
    {
      "id": "e304b4a3afc9985ef42898953bbb4c4c2209d80b9c683042b9eca3daf720a4c2",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "version": "3.1.3",
      "release_id": "JTTYW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T17:47:50Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674733M/1/Express-Flash-PCIe-SSD_Firmware_JTTYW_WN64_3.1.3_A06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTTYW",
      "size": 19213864,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "457ece2bc644069fab86e59d8d629ce72abd2ea321c4374bec6ae5340321f69f",
      "name": "Samsung PM9A3 NVMe M.2 22x110 for FW 1.1.1 version for model numbers(s) MZ1L2960HCJR-00AD3, MZ1L21T9HCLS-00AD3.",
      "version": "1.1.1",
      "release_id": "HX5W6",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-20T10:56:05Z",
      "released": "2024-05-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11638925M/1/Express-Flash-PCIe-SSD_Firmware_HX5W6_WN64_1.1.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HX5W6",
      "size": 9471384,
      "reboot_required": false,
      "description": "Samsung PM9A3 NVMe M.2 22x110 for FW 1.1.1 version for model numbers(s) MZ1L2960HCJR-00AD3, MZ1L21T9HCLS-00AD3. \n\nThis update includes important reliability enhancements and also improves drive enumeration. Firmware version 1.1.1 for Samsung PM9A3 M.2 drives, models MZ1L21T9HCLS-00AD3 and MZ1L2960HCJR-00AD3.",
      "revision_history": "Disable (LTR( Latency Tolerance Reporting) to avoid delays on non-supported systems\n- Additional command syntax updates.\n- Add Log page C0 support"
    },
    {
      "id": "011cb51c31d6a54ec99d1838077c9124306b4910ee57754ecff998648108b714",
      "name": "SK Hynix PE80X0 SP M.2 ISE FW 1.3.0 version for model numbers HFS480GDC8X099N, HFS800GDC8X088N, HFS960GDC8X099N, HFS1T9GDC8X099N",
      "version": "1.3.0",
      "release_id": "R2TTT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-03T18:43:23Z",
      "released": "2024-05-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11576366M/1/Express-Flash-PCIe-SSD_Firmware_R2TTT_WN64_1.3.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R2TTT",
      "size": 9310536,
      "reboot_required": false,
      "description": "This release contains the SK Hynix PE80X0 ISE FW 1.3.0 version for model number(s) HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X088N, HFS480GDC8X096N.",
      "revision_history": "Fixes: \n\n- Under certain conditions, the drive may become unresponsive causing the BOSS (Boot Optimized Storage Card) virtual LUN to go offline."
    },
    {
      "id": "006c7f97b61850b4e18ebe89988c181f485be2e0b9b256d6c63ef1a257aad711",
      "name": "SK Hynix PE80X0 M.2 Opal/SED drive firmware 1.3.0 for model numbers HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X096N, HFS480GDC8X096N.",
      "version": "1.3.0",
      "release_id": "4NH4W",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-03T18:09:57Z",
      "released": "2024-05-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11576312M/1/Express-Flash-PCIe-SSD_Firmware_4NH4W_WN64_1.3.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4NH4W",
      "size": 9530648,
      "reboot_required": false,
      "description": "This release contains FW version 1.3.0 for SK Hynix PE80X0 M.2 Opal/SED drives HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X096N, HFS480GDC8X096N.",
      "revision_history": "Fixes: \n\n- Under certain conditions, the drive may become unresponsive causing the BOSS (Boot Optimized Storage Card) virtual LUN to go offline."
    },
    {
      "id": "b13653ba58538fde3cac8d496259c29f71688f8579a86a1ccc1f710fac17544a",
      "name": "Windows Server 2022 64bit driver for PERC S160 Controller",
      "version": "7.3.0.0003",
      "release_id": "C8884",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T13:43:53Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422048M/1/SAS-RAID_Driver_C8884_WN64_7.3.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C8884",
      "size": 6626752,
      "reboot_required": true,
      "description": "Windows Server 2022 64bit driver for PERC S160 Controller"
    },
    {
      "id": "7fe6b0b3ce7bd52daba053a0df2aa4d86161ebd59da1f5a101fc76cca1506a66",
      "name": "Windows Server 2019 64bit driver for PERC S160 Controller",
      "version": "7.3.0.0003",
      "release_id": "NXM3F",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T13:38:33Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422020M/1/SAS-RAID_Driver_NXM3F_WN64_7.3.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NXM3F",
      "size": 6625408,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S160 Controller"
    },
    {
      "id": "4db1c2d8d2f971c4bbb13d3fe438f3b2ed755ca69c079fd234d6f85e39cb49a9",
      "name": "SK Hynix PE8110 M.2 ISE FW for model number(s) HFS3T8GDE0X088N, HFS1T9GDE0X088N",
      "version": "1.1.0",
      "release_id": "19H08",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-03-19T10:40:15Z",
      "released": "2024-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11394086M/1/Express-Flash-PCIe-SSD_Firmware_19H08_WN64_1.1.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=19H08",
      "size": 10681904,
      "reboot_required": false,
      "description": "This release contains the SK Hynix PE8110 ISE FW 1.1.0 version for model number(s) HFS3T8GDE0X088N, HFS1T9GDE0X088N",
      "revision_history": "Fixes:\n\n- Fixes issue with DST.DST will not fail if critical temperature warning bit is set."
    },
    {
      "id": "34c7cdbe33ff6937951237e4688c782c36ce0c1a9a134c21f78be30e094dd3e1",
      "name": "Dell Express Flash NVMe P5500/P5600 PCIe SSD Firmware Release",
      "version": "1.2.4",
      "release_id": "CGXH7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-03-07T15:53:46Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09999738M/2/Express-Flash-PCIe-SSD_Firmware_CGXH7_WN64_1.2.4_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CGXH7",
      "size": 17251184,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P5500/5600 PCIe SSD Firmware Release",
      "revision_history": "N/A"
    },
    {
      "id": "8b7171c9e267a84502b4dd3b631bc09cc0e0ab25b12cc110d8273af3b0f84615",
      "name": "Seagate 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "version": "4S0C",
      "release_id": "G04C8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-12T12:12:27Z",
      "released": "2022-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08459420M/2/SAS-Drive_Firmware_G04C8_WN64_4S0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G04C8",
      "size": 12625072,
      "reboot_required": false,
      "description": "This release contains Seagate firmware version 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "revision_history": "Fixes:\n-Fix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\n-Fix an issue that can return corrupt data after a power cycle in a corner case.\n-Fix an issue that can return the sense code 09/80/00 to a WRITE command.\n-Fix issues that can cause command timeout.\n-Fix issues that can cause drive assert.\n-Fix issues that can cause drive hang condition.\n\nEnhancements:\n-Improve protocol spec compliance.\n-Improve throughput performance for specific workloads.\n-Improve error logging/sense data reporting.\n-\nFix an issue that can cause drive-not-ready."
    },
    {
      "id": "9431d253a03a2caca577166cfc03127602ee59a930310d0e3511af1aca6a0b67",
      "name": "Dell Express Flash NVMe PCIe SSD CD7 U.2 OPAL Firmware Maintenance Release",
      "version": "1.0.1",
      "release_id": "XRT9C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T04:54:35Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09992794M/2/Express-Flash-PCIe-SSD_Firmware_XRT9C_WN64_1.0.1_A02_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XRT9C",
      "size": 18341424,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD7 U.2 OPAL Firmware Release",
      "revision_history": "Fixes:\nN/A\n\nEnhancements:\nAdded PERC 12 Support"
    },
    {
      "id": "3b764d1917ceefc3992a34fb936d2458b1dfd4ea153d4f5f4479e2695234114e",
      "name": "Dell Express Flash NVMe PCIe SSD CD7 U.2 ISE Firmware Release",
      "version": "2.0.1",
      "release_id": "K6597",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T04:46:16Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09992830M/2/Express-Flash-PCIe-SSD_Firmware_K6597_WN64_2.0.1_A02_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K6597",
      "size": 18137576,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD7 U.2 ISE Firmware Release",
      "revision_history": "Fixes:\nN/A\n\nEnhancements:\nAdded PERC 12 Support"
    },
    {
      "id": "d31a2b80867c52171a4c1e341a06b8297f7e871256099e506254c6a5c135d640",
      "name": "Dell PowerEdge Express Flash Ent NVMe v2 FIPS AGN Maintenance Firmware Release",
      "version": "3.5.0",
      "release_id": "2VG67",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:37:22Z",
      "released": "2023-11-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10824098M/2/Express-Flash-PCIe-SSD_Firmware_2VG67_WN64_3.5.0_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2VG67",
      "size": 21774520,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe v2 FIPS AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. NVMe-MI improvements.\n2. Persistent Event Log improvements.\n3. Fixed inssue with firmware update over NVMe-MI\n4. Drive becomes unresponsive after a reboot when TCG commands are outstanding.\n5. Corrected reported shutdown timeout values for 3.84TB, 6.4TB and 7.68TB capacity drives.\n\n\nEnhancements:\n\n1. Media access over sideband improvements.\n2. Enable Relaxed Ordering."
    },
    {
      "id": "d3068e476ab86d35d740df46573b012a443c549c62d3faca73aff63257f9e5fa",
      "name": "Dell PowerEdge Express Flash Ent NVMe v2 AGN Maintenance Firmware Release",
      "version": "2.5.0",
      "release_id": "5V3P7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:37:00Z",
      "released": "2023-11-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10823865M/2/Express-Flash-PCIe-SSD_Firmware_5V3P7_WN64_2.5.0_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5V3P7",
      "size": 21761944,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe v2 AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. NVMe-MI improvements.\n2. Persistent Event Log improvements.\n3. Fixed inssue with firmware update over NVMe-MI\n4. Drive becomes unresponsive after a reboot when TCG commands are outstanding.\n5. Corrected reported shutdown timeout values for 3.84TB, 6.4TB and 7.68TB capacity drives.\n\n\nEnhancements:\n\n1. Media access over sideband improvements.\n2. Enable Relaxed Ordering."
    },
    {
      "id": "851a48e9ba600ab67df61a16c04e18dcb1a8585e199a47ef484169481a12d1c2",
      "name": "Dell PowerEdge Express Flash Ent NVMe PE8010 SED Maintenance Firmware Release",
      "version": "1.3.0",
      "release_id": "C2C5M",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-01T15:27:03Z",
      "released": "2023-12-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10917317M/2/Express-Flash-PCIe-SSD_Firmware_C2C5M_WN64_1.3.0_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C2C5M",
      "size": 20144680,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash Ent NVMe PE8010 SED Firmware Release",
      "revision_history": "N/A"
    },
    {
      "id": "fcedf881f952e18cb7886f5bae15f0f5b345a33ba459c4e4e6004394bc50777b",
      "name": "Dell PowerEdge Express Flash Ent NVMe PE8010 Firmware Release",
      "version": "1.3.0",
      "release_id": "T1XKD",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T15:24:28Z",
      "released": "2023-08-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10443052M/3/Express-Flash-PCIe-SSD_Firmware_T1XKD_WN64_1.3.0_A04_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T1XKD",
      "size": 19878392,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash Ent NVMe PE8010 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected LED behavior to adhere to LED specifications\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "480d4e9ce14a83d2047d570eaf2ae2092e247347f514a1ca3e9da63fa1704440",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 22.7 update.",
      "version": "22.71.11.10",
      "release_id": "1TT78",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2024-01-31T23:20:53Z",
      "released": "2023-09-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10551555M/2/Network_Driver_1TT78_WN64_22.71.11.10_227.1.111.0_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1TT78",
      "size": 5933280,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.",
      "revision_history": "Fixes:\n- None.\n\nEnhancements:\n- Support for additional PowerEdge server models."
    },
    {
      "id": "eeb214c6eeee69a5f0df9a8a636c9e2cb91affb59cdc9a3d676d62028dad541d",
      "name": "Micron K803 for 5400 SATA model number(s) MTFDDAK7T6TGA",
      "version": "K803",
      "release_id": "333Y2",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-30T06:44:45Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606516M/2/Serial-ATA_Firmware_333Y2_WN64_K803_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=333Y2",
      "size": 12359152,
      "reboot_required": false,
      "description": "This release contains firmware version K803 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK7T6TGA",
      "revision_history": "Fixes:\n- Fixes to address performance."
    },
    {
      "id": "6c992026ccb1034e5d76c43933dc44c2595da3c48f49b380535843c14de95847",
      "name": "Micron K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "version": "K003",
      "release_id": "RJ0WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T14:41:30Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606437M/2/Serial-ATA_Firmware_RJ0WY_WN64_K003_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJ0WY",
      "size": 12627936,
      "reboot_required": false,
      "description": "This release contains firmware version K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "revision_history": "Fixes:\n\n-Fixes to address performance."
    },
    {
      "id": "7f5691c4430c7327b0a80ce3ef83995daadc50336c7a6a3a67edf9b560b1db34",
      "name": "Micron K403 for 5400 SATA model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB",
      "version": "K403",
      "release_id": "JTW3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T06:58:14Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606566M/2/Serial-ATA_Firmware_JTW3W_WN64_K403_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTW3W",
      "size": 12364032,
      "reboot_required": false,
      "description": "This release contains firmware version K403 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB.",
      "revision_history": "Fixes:\n\n- Fixes to address performance."
    },
    {
      "id": "bb82cbf99973004ad4fa46b9d064ac1b23ea7e421990eef9b1994703259e53e1",
      "name": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095",
      "version": "CPE9",
      "release_id": "RRWVT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:56:16Z",
      "released": "2023-09-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10235085M/2/SAS-Drive_Firmware_RRWVT_WN64_CPE9_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RRWVT",
      "size": 12063856,
      "reboot_required": false,
      "description": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095,XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n- Fix drive detection issue.\n\nEnhancements:\n- Enable new DPN for 7.68TB capacity."
    },
    {
      "id": "51252624b4929e0e9c705e59c55fca91ae5867bfb2b5bb21680df2b58fd499d0",
      "name": "Windows Server 2019 Driver 2.61.48.00 for HBA10-11 Controllers",
      "version": "2.61.48.00",
      "release_id": "WFV95",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-01-05T04:18:59Z",
      "released": "2023-03-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09649518M/2/SAS-Non-RAID_Driver_WFV95_WN64_2.61.48.00_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WFV95",
      "size": 6524184,
      "reboot_required": true,
      "description": "This release updates Windows 2019 Server driver to 2.61.48.00 for HBA345 Adapter/Front, HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter/MX/MM/MMLP Controllers.",
      "revision_history": "N/A"
    },
    {
      "id": "1422bba58673005e0d8a1f7d9ee1c898c81706f760e54c181b8a463dce6c5e22",
      "name": "Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "version": "BJ07",
      "release_id": "5WMK8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:21:19Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933394M/1/SAS-Drive_Firmware_5WMK8_WN64_BJ07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5WMK8",
      "size": 12038824,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "c855860fcea8e28b218e1a411e459df231843af673b1b74063fb0651ac68c681",
      "name": "Windows Server 2022 Driver 7.726.01.00 for PERC Controllers",
      "version": "7.726.01.0",
      "release_id": "WC00M",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-02T22:19:12Z",
      "released": "2023-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10807838M/1/SAS-RAID_Driver_WC00M_WN64_7.726.01.0_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WC00M",
      "size": 6194480,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver to 7.726.01.0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers."
    },
    {
      "id": "1bd85f6bd394bc927689e01db4206561ec946a6b01a7579299d2a9ee26ef0920",
      "name": "Windows Server 2019 Driver 7.726.01.0 for PERC Controllers",
      "version": "7.726.01.0",
      "release_id": "44R58",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-02T22:15:59Z",
      "released": "2023-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10807826M/1/SAS-RAID_Driver_44R58_WN64_7.726.01.0_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=44R58",
      "size": 6196192,
      "reboot_required": true,
      "description": "This release updates Windows 2019 Server driver to 7.726.01.0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers."
    },
    {
      "id": "f00b0fb442568fef33a6e6b6f803cb2d327c1864b57c2f40c77208c11a0cff75",
      "name": "Intel NIC Family Version 22.5.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "22.5.7",
      "release_id": "1R0W0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T21:01:32Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646142M/1/Network_Firmware_1R0W0_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1R0W0",
      "size": 36581360,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "fe3df57f88a24821dcfe6da938dea1cb5969fd93d89df900376eb41cf1b3ac98",
      "name": "Intel NIC Family Version 22.5.0 Firmware for I350, I354, and X550 Adapters",
      "version": "22.5.7",
      "release_id": "TNXW1",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T20:37:20Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646092M/2/Network_Firmware_TNXW1_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TNXW1",
      "size": 16735312,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "1b93b4e39384176023ffc076dcc78d84a5de9901d76ecc2d947776c3d6934cfe",
      "name": "Windows Server 2022 Driver 2.61.48.00 for HBA10-11 Controllers",
      "version": "2.61.48.00",
      "release_id": "M2P63",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-09-22T12:09:30Z",
      "released": "2023-03-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09649533M/5/SAS-Non-RAID_Driver_M2P63_WN64_2.61.48.00_A02_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M2P63",
      "size": 6527320,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver to 2.61.48.00 for HBA345 Adapter/Front, HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter/MX/MM/MMLP Controllers.",
      "revision_history": "NA"
    },
    {
      "id": "7f3c1816a8abb0d5de05c5772def174d0e1ae5f6c9c2ad5523fd664903346ed8",
      "name": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "version": "CSJA",
      "release_id": "J12RT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-06-30T05:01:47Z",
      "released": "2023-06-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10268173M/1/SAS-Drive_Firmware_J12RT_WN64_CSJA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J12RT",
      "size": 12687840,
      "reboot_required": false,
      "description": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSJ8."
    },
    {
      "id": "41918bd0bc2e05c6eb1fc65a8c7bb009dceb1291997feccc49bef3b1547fe821",
      "name": "Kioxia BH03 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "version": "BH03",
      "release_id": "C8CVG",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-06-26T17:37:04Z",
      "released": "2023-06-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10247472M/1/SAS-Drive_Firmware_C8CVG_WN64_BH03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C8CVG",
      "size": 12181328,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BH03 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "revision_history": "Following two countermeasures were added to reduce the occurrence probability of PMIC busy issue.\n1.Rationalize PMIC I2C commands.\n2.Reduce PLP Capacity Patrol frequency."
    },
    {
      "id": "d6784baaf602be53256144a13d13ccebfe0dd5110a4cb33a3573fb5e5f7f467f",
      "name": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "version": "CPE6",
      "release_id": "2PY92",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-12-14T07:32:22Z",
      "released": "2022-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09346116M/1/SAS-Drive_Firmware_2PY92_WN64_CPE6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2PY92",
      "size": 12209992,
      "reboot_required": false,
      "description": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n-Initial Release"
    },
    {
      "id": "52ba9199170025361e5f786bb771721f0338a90cfdd142cf80e032aa5740cc88",
      "name": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68.",
      "version": "BD48",
      "release_id": "G42W2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-07-13T11:34:31Z",
      "released": "2022-07-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08765004M/1/SAS-Drive_Firmware_G42W2_WN64_BD48_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G42W2",
      "size": 12181976,
      "reboot_required": false,
      "description": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68.",
      "revision_history": "Fixes : \n- Initial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    }
  ]
}