  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "xr12",
  "name": "XR12",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XR12 Urgent Updates",
  "filter": "urgent",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 20,
      "rss": "/xr12/urgent/rss.xml",
      "api": "/api/xr12/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 86,
      "rss": "/xr12/recommended/rss.xml",
      "api": "/api/xr12/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 50,
      "rss": "/xr12/optional/rss.xml",
      "api": "/api/xr12/optional"
    },
    {
      "slug": "accelerators",
      "label": "Accelerators",
      "count": 1,
      "rss": "/xr12/accelerators/rss.xml",
      "api": "/api/xr12/accelerators"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xr12/bios/rss.xml",
      "api": "/api/xr12/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/xr12/chipset/rss.xml",
      "api": "/api/xr12/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/xr12/diagnostics/rss.xml",
      "api": "/api/xr12/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xr12/drivers-for-os-deployment/rss.xml",
      "api": "/api/xr12/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 31,
      "rss": "/xr12/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xr12/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xr12/firmware/rss.xml",
      "api": "/api/xr12/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xr12/idrac/rss.xml",
      "api": "/api/xr12/idrac"
    },
    {
      "slug": "memory",
      "label": "Memory",
      "count": 1,
      "rss": "/xr12/memory/rss.xml",
      "api": "/api/xr12/memory"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 29,
      "rss": "/xr12/network/rss.xml",
      "api": "/api/xr12/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 29,
      "rss": "/xr12/sas-drive/rss.xml",
      "api": "/api/xr12/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 11,
      "rss": "/xr12/sas-non-raid/rss.xml",
      "api": "/api/xr12/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 17,
      "rss": "/xr12/sas-raid/rss.xml",
      "api": "/api/xr12/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/xr12/security/rss.xml",
      "api": "/api/xr12/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 27,
      "rss": "/xr12/serial-ata/rss.xml",
      "api": "/api/xr12/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/xr12/systems-management/rss.xml",
      "api": "/api/xr12/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/xr12/video/rss.xml",
      "api": "/api/xr12/video"
    }
  ],
  "count": 20,
  "updates": [
    {
      "id": "d8f0fac682278579b9ed83fbe1ed3b2e3ac8076fa58545aa7b68d4c77cc5cc02",
      "name": "Dell Server PowerEdge XR11/XR12 BIOS Version 1.23.3",
      "version": "1.23.3",
      "release_id": "88NPF",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-11-04T09:40:55Z",
      "released": "2026-11-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15203412M/1/BIOS_88NPF_WN64_1.23.3.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=88NPF",
      "size": 41815096,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced features sections",
      "revision_history": "Enhancements\n- This product release contains security update DSA-2026-470, DSA-2026-471. Any security fix information will be accessible on the Dell Security Advisories and Notices website."
    },
    {
      "id": "3c42a5d5d6593d1bb6afbb03bfc0943458d93671a8a9b79d91ec42193d56871e",
      "name": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "GF3PY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-11-03T17:31:07Z",
      "released": "2026-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199882M/1/Express-Flash-PCIe-SSD_Firmware_GF3PY_WN64_1.5.0_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GF3PY",
      "size": 38306408,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release"
    },
    {
      "id": "8ad48dc6cae6e8b03aebff02644f0ded7985077dfa26073f61c431a78bdd9861",
      "name": "PERC H840 Controller Firmware 51.16.0-5148",
      "version": "51.16.0-5148",
      "release_id": "M9DDF",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-06-04T14:19:06Z",
      "released": "2023-10-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10676386M/2/SAS-RAID_Firmware_M9DDF_WN64_51.16.0-5148_A18_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M9DDF",
      "size": 19972656,
      "reboot_required": true,
      "description": "This release updates the firmware residing on H840 controllers to package 51.16.0-5148",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions, including Single Bit Errors (SBE) and Multi Bit Errors (MBE).\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown to power off the system, followed by a power on to enable the new memory settings.\nA warm reboot will NOT activate the updated settings.\nIf iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required."
    },
    {
      "id": "2576d421636e87b519086721087196201ac74ebd37755dce4f70eb579e503d8d",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release Maintenance Firmware",
      "version": "1.3.1",
      "release_id": "N78NP",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-03T19:47:31Z",
      "released": "2026-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14259015M/1/Express-Flash-PCIe-SSD_Firmware_N78NP_WN64_1.3.1_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N78NP",
      "size": 27170488,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release - Maintenance Firmware",
      "revision_history": "Fixes:  \n\n1. Improved the firmware to ensure internal PCIe register access is done according to the specification.\n2. Updated the firmware to add SCL detection/protection\n3. Improved firmware to detect the noise on power rail.\n4. Improved firmware to add detection/protection for incomplete Host-Initiated Data Transfer\n5. Improved firmware to add detection/protection for drive Initialization with Poor PCIe Signal Integrity\n6. Improved firmware to add detection and initiate rest/recovery operation to the power management controller upon power on.\n7. Updated the firmware to prevent the deadlock scenario while extended Host Idle Time (no SSD device I/O)\n8. Updated the firmware to Enable PCIe relaxed ordering\n\nEnhancements:  \nN/A"
    },
    {
      "id": "81f3f0352d8bd36411685ecdc38bb84a5468b5da7af2f25ab5aab2a8dfeff25a",
      "name": "Dell Express Flash NVMe P4510/P4610 PCIe SSD Firmware Release",
      "version": "VDV1DP25",
      "release_id": "7VJGR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-01-20T19:54:52Z",
      "released": "2026-01-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14110355M/1/Express-Flash-PCIe-SSD_Firmware_7VJGR_WN64_VDV1DP25_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7VJGR",
      "size": 27548008,
      "reboot_required": true,
      "description": "This release contains firmware for Intel drives with the following model numbers: Dell Express Flash Nvme P4510 1TB, Dell Express Flash NVMe P4510 2TB, Dell Express Flash NVMe P4510 4TB, Dell Express Flash NVMe P4510 8TB, Dell Express Flash NVMe P4610 1.6TB, Dell Express Flash NVMe P4610 3.2TB, Dell Express Flash NVMe P4610 6.4TB"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "b3756f56e76fb6fdf6d53d9bc0bb41fa37aaf9ec858ba959301334044cd538e7",
      "name": "DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR",
      "version": "DL7C",
      "release_id": "VJPKG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-08-19T07:07:49Z",
      "released": "2025-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12600340M/4/Serial-ATA_Firmware_VJPKG_WN64_DL7C_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJPKG",
      "size": 22988728,
      "reboot_required": false,
      "description": "This is a firmware release for DELLSLDM Youngsville-RR  DL7C firmware for Model number(s) SSDSC2KB240GZR, SSDSC2KB480GZR, SSDSC2KB960GZR, SSDSC2KB019TZR, SSDSC2KB038TZR, SSDSC2KB076TZR, SSDSCKKB240GZR, SSDSCKKB480GZR,SSDSC2KG480GZR, SSDSC2KG960GZR, SSDSC2KG019TZR, SSDSC2KG038TZR",
      "revision_history": "Issue: During a warm Reboot the YVRR drive may intermittently disappear when connected to the PERC H965i\nFix: DL7C FW now addresses this issue\nIssue: PLI capacitor charge flag not set leads drive to enter disable logical mode\nFix: DL7C FW now addresses this issue"
    },
    {
      "id": "d7118a4011a988e2e951915d1cc298925ca524ddf11d30cbbcda0b4011e70320",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.4.0",
      "release_id": "TVCWT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-07-11T04:31:50Z",
      "released": "2025-07-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13369867M/1/Express-Flash-PCIe-SSD_Firmware_TVCWT_WN64_1.4.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TVCWT",
      "size": 29064896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo be added"
    },
    {
      "id": "2d691ed72b31c474544f0a9a0818d69f0e4ab820992ea73115f41143fafef850",
      "name": "WD BCQ firmware G138  for model numbers WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200,WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200,WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200",
      "version": "G138",
      "release_id": "8W5WF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T07:34:09Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11655805M/1/SAS-Drive_Firmware_8W5WF_WN64_G138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8W5WF",
      "size": 12585960,
      "reboot_required": false,
      "description": "This release contains firmware version G138 for WD BCQ drives. Vendor model numbers WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200, WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200, WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries."
    },
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "ec7b4413408504ee11e7cc02edb1960d318d54ce4c0cfc3635ef7ba19403b254",
      "name": "SK HYNIX DE08 for model numbers HFS960G32FEH-7A10A, HFS1T9G32FEH-7A10A, HFS3T8G32FEH-7410A and HFS480G32FEH-7410A",
      "version": "DE08",
      "release_id": "3DTV4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T03:52:03Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11629605M/1/Serial-ATA_Firmware_3DTV4_WN64_DE08_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3DTV4",
      "size": 13594832,
      "reboot_required": false,
      "description": "This release contains firmware version DE08 for SK HYNIX model numbers HFS960G32FEH-7A10A, HFS1T9G32FEH-7A10A, HFS3T8G32FEH-7410A and HFS480G32FEH-7410A.",
      "revision_history": "Fix: \n\n- Improvements made to Background Scanning functionality"
    },
    {
      "id": "333f510745d6bedcbadf00dfa27e5b7532c32ae94fea09bd9ec4a93617b1329f",
      "name": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s)  KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960",
      "version": "CA0C",
      "release_id": "1YD58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T15:53:43Z",
      "released": "2023-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10810459M/2/SAS-Drive_Firmware_1YD58_WN64_CA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1YD58",
      "size": 12708760,
      "reboot_required": false,
      "description": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s) KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960G.",
      "revision_history": "Fixes: \nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed in a different area, the drive may encounter the below failure mode. Once a drive falls into this failure mode, it cannot be recovered by power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. Data buffer is used for data transfer during Wear-Leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow.                                                                                                             Write Cache Issue: An issue that may cause firmware downloads to fail in the event of a capacitor failure. This failure is triggered by firmware download in the Write Cache Off state, and even if it occurs, it does not lead to drive failure and can be recovered by a reset or Power cycle.\nCause: When FW Update is executed in the Write Cache Off state and then restarted, capacitor discharge control is activated. In this case, unintended PLP occurs because capacitor discharge was controlled in the order of capacitor discharge and then PLP interrupt mask.\nFix: When capacitor discharge control is executed after FW Update in the Write Cache Off state and the system is restarted, the PLP interrupt mask is changed to control in the order of PLP interrupt mask and then capacitor discharge."
    },
    {
      "id": "8b123fe887879d8ad789dc986b35da9f2ec22affe26654a6bb6e8b20640f3cc6",
      "name": "Windows Server 2019 64bit driver for PERC S150 Controller",
      "version": "6.7.0.0003",
      "release_id": "XVCP2",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T16:00:59Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422723M/1/SAS-RAID_Driver_XVCP2_WN64_6.7.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XVCP2",
      "size": 6625104,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S150 Controller"
    },
    {
      "id": "8b7171c9e267a84502b4dd3b631bc09cc0e0ab25b12cc110d8273af3b0f84615",
      "name": "Seagate 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "version": "4S0C",
      "release_id": "G04C8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-12T12:12:27Z",
      "released": "2022-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08459420M/2/SAS-Drive_Firmware_G04C8_WN64_4S0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G04C8",
      "size": 12625072,
      "reboot_required": false,
      "description": "This release contains Seagate firmware version 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "revision_history": "Fixes:\n-Fix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\n-Fix an issue that can return corrupt data after a power cycle in a corner case.\n-Fix an issue that can return the sense code 09/80/00 to a WRITE command.\n-Fix issues that can cause command timeout.\n-Fix issues that can cause drive assert.\n-Fix issues that can cause drive hang condition.\n\nEnhancements:\n-Improve protocol spec compliance.\n-Improve throughput performance for specific workloads.\n-Improve error logging/sense data reporting.\n-\nFix an issue that can cause drive-not-ready."
    },
    {
      "id": "5086e78dc030867d4946fe97008ff36bf0257aa011025b9bd1e283a60cc72e2d",
      "name": "Samsung PM1645a drive for FW DWA4 for Model number(s):MZILT800HBHQ0D3, MZILT1T6HBJR0D3, MZILT3T2HBLS0D3.",
      "version": "DWA4",
      "release_id": "VJY6V",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:39:09Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08613033M/2/SAS-Drive_Firmware_VJY6V_WN64_DWA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJY6V",
      "size": 11323344,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1645a drive for Model number(s):MZILT800HBHQ0D3, MZILT1T6HBJR0D3, MZILT3T2HBLS0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "121c2c65e1e9a03b00d25ba579c34f484234d576609fe0ed7e6c5860d47a0e0b",
      "name": "Samsung PM1643a drives for FW DSA4 for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "version": "DSA4",
      "release_id": "D7RNT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:05:17Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08612628M/2/SAS-Drive_Firmware_D7RNT_WN64_DSA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D7RNT",
      "size": 11328112,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1643a drives for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "464b59fe39812588c5713e0530dbe62d1c68c051dda5e2cf1656c70d85840571",
      "name": "Micron 5300 SED J808 firmware for model number MTFDDAK7T6TDS",
      "version": "J808",
      "release_id": "7X7KX",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-08-04T09:11:19Z",
      "released": "2023-08-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10433234M/1/Serial-ATA_Firmware_7X7KX_WN64_J808_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7X7KX",
      "size": 11866584,
      "reboot_required": false,
      "description": "This  release contains  firmware for Micron 5300 SED drives (7.68TB capacity).  Firmware version J808 for Micron 5300 SED drives, model MTFDDAK7T6TDS..",
      "revision_history": "Fixes:\n-Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "6b01a365cd3ec211f0220c2550d15f29848832f62579e2e64a7467874c94f2fa",
      "name": "Seagate 4D0C for model number(s) XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "version": "4D0C",
      "release_id": "NX13G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-04-28T10:32:00Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486562M/1/SAS-Drive_Firmware_NX13G_WN64_4D0C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NX13G",
      "size": 11833104,
      "reboot_required": false,
      "description": "This release contains firmware version 4D0C for Seagate drives. Vendor model numbers XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "revision_history": "Fixes:\nFix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can return corrupt data after a power cycle in a corner case.\nFix an issue that can return the sense code 09/80/00 to a WRITE command.\nFix issues that can cause command timeout.\nFix issues that can cause drive assert.\nFix issues that can cause drive hang condition.\nFix an issue that can cause drive-not-ready.\nEnhancements:\nImprove protocol spec compliance.\nImprove throughput performance for specific workloads.\nImprove error logging/sense data reporting."
    },
    {
      "id": "9f54d16b6a912067843cc2bd8568d7b9c3911cac62f7725298299613a5828fca",
      "name": "Seagate Lange Firmware Version EC16  for model number(s) XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "version": "EC16",
      "release_id": "H3VHX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-02-04T09:29:43Z",
      "released": "2021-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07035193M/1/SAS-Drive_Firmware_H3VHX_WN64_EC16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3VHX",
      "size": 10683112,
      "reboot_required": false,
      "description": "This release contains firmware version EC16 for Seagate drives. Vendor model numbers XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "revision_history": "Fixes:\n-Fix an issue where reading or writing of corrupt data can result after a power cycle\n-Fix an issue which can lead to reduced data retention duration\n-Fix an issue where assert can result when max. queue depth is exceeded\n-Update activity LED blinking behavior to be consistent with Dell requirements\n\nEnhancements:\n-N/A"
    }
  ]
}