{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "xe9785l",
  "name": "XE9785L",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XE9785L Express Flash PCIe SSD Updates",
  "filter": "express-flash-pcie-ssd",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 5,
      "rss": "/xe9785l/urgent/rss.xml",
      "api": "/api/xe9785l/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 13,
      "rss": "/xe9785l/recommended/rss.xml",
      "api": "/api/xe9785l/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 11,
      "rss": "/xe9785l/optional/rss.xml",
      "api": "/api/xe9785l/optional"
    },
    {
      "slug": "accelerators",
      "label": "Accelerators",
      "count": 3,
      "rss": "/xe9785l/accelerators/rss.xml",
      "api": "/api/xe9785l/accelerators"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xe9785l/bios/rss.xml",
      "api": "/api/xe9785l/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 2,
      "rss": "/xe9785l/boss/rss.xml",
      "api": "/api/xe9785l/boss"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xe9785l/drivers-for-os-deployment/rss.xml",
      "api": "/api/xe9785l/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 12,
      "rss": "/xe9785l/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xe9785l/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xe9785l/firmware/rss.xml",
      "api": "/api/xe9785l/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xe9785l/idrac/rss.xml",
      "api": "/api/xe9785l/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 5,
      "rss": "/xe9785l/network/rss.xml",
      "api": "/api/xe9785l/network"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/xe9785l/security/rss.xml",
      "api": "/api/xe9785l/security"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/xe9785l/systems-management/rss.xml",
      "api": "/api/xe9785l/systems-management"
    }
  ],
  "count": 12,
  "updates": [
    {
      "id": "1946160ed0d0cb3359a20dfca14e8078ecac5f014fd8979c0efcaa3a71e82245",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "version": "1.1.0",
      "release_id": "4WN4V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-23T16:20:58Z",
      "released": "2026-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14428501M/2/Express-Flash-PCIe-SSD_Firmware_4WN4V_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4WN4V",
      "size": 34529136,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n1. Modified the FW to track second level read recovery triggers.\n2. Developed a firmware fix to add separate queues in the CPU coupled memory to monitor and control the flow of push \u0026 pop entries in the linked list to eliminate any possibility of unexpected concurrent accesses. A dedicated CPU is used for this solution to minimize performance impact.\n3. Modified the FW to set the pointer value to the designated structured memory area.\n4. Updated the firmware to optimize internal operations under this back-to-back power cycle scenario to properly manage APL interrupt.\n5. Updated the firmware to check the thermal throttling stage and manage the resource allocation appropriately before the initiating APL handling.\n6. Enhanced the firmware to handle the back-to-back PERST# operations to ensure that no transitions are missed.\n7. Updated the firmware to increase the PCIe bridge timeout to 1ms\n\nEnhancements:  \n1. Updated the FW to increase the CAP.TO value to 30 seconds for 9550 product family\n2. Updated the Firmware to correct the eye measurement algorithm to appropriately handle PCIe errors conditions.\n3. Enhanced the firmware to optimize folding operations under these specific workloads to improve performance consistency.\n4. Updated the firmware to keep the activity LED on when the host disables the controller (CC.EN=0)"
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "11627fb16dae8be6533ae44611508823df7dfc7d630b3da2e026012a1e143926",
      "name": "Dell Express Flash NVMe PCIe SSD 7600 U.2 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "VJXKC",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-09T04:07:55Z",
      "released": "2026-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14057449M/1/Express-Flash-PCIe-SSD_Firmware_VJXKC_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJXKC",
      "size": 30405520,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7600 U.2 ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any Linux OS. Either use Windows, or iDRAC for FW update. - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "03de1d08414a2b511614268e4a3d7ddf38fb318e34a27f7dec7fcf35c69497f2",
      "name": "Dell Express Flash NVMe PCIe SSD CM6 FIPS Maintenance Firmware Release",
      "version": "3.1.7",
      "release_id": "WJD95",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-10T05:56:19Z",
      "released": "2024-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11856439M/3/Express-Flash-PCIe-SSD_Firmware_WJD95_WN64_3.1.7_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WJD95",
      "size": 28731088,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM6 FIPS Firmware Maintenance Release",
      "revision_history": "N/A"
    },
    {
      "id": "cb5e5f744b7e82ee6fb7befc7000015d43c90b63725daab201de0d39766f58d2",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release Maintenance Firmware",
      "version": "1.2.0",
      "release_id": "5F07C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-07-18T20:42:21Z",
      "released": "2025-07-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13402800M/1/Express-Flash-PCIe-SSD_Firmware_5F07C_WN64_1.2.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5F07C",
      "size": 29234304,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release - Maintenance Firmware",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo be added"
    },
    {
      "id": "94586f99bddb6d07e51ebf78479fa5de5fb353777dec7e7bb0b73c704b3c21bf",
      "name": "Dell Datacenter NVME RI AGN ISE",
      "version": "1.1.1",
      "release_id": "XMFKX",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:50:32Z",
      "released": "2024-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12037085M/2/Express-Flash-PCIe-SSD_Firmware_XMFKX_WN64_1.1.1_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XMFKX",
      "size": 30415680,
      "reboot_required": false,
      "description": "Dell Datacenter NVME RI AGN ISE",
      "revision_history": "Fixes:\n\n1. Updated DUP framework for 17G server platforms."
    },
    {
      "id": "355a10aa0961ec37be75aaf10781afadea86500859aec3f9b03e845a4cea30c9",
      "name": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.1",
      "release_id": "HV8P1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T10:58:34Z",
      "released": "2025-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12428245M/2/Express-Flash-PCIe-SSD_Firmware_HV8P1_WN64_2.0.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HV8P1",
      "size": 29591112,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. For PCI Information such as PCI Vendor ID other than BDF, FW also keeps their value. So, fixed to respond the value directly from FW instead of getting them from HW.\n2. Instead of clearing the Abort flag at the beginning of the response data retransfer processing task, modify it to clear the Abort flag when data transfer after retransfer becomes possible.\n3. Fix the bug that write index of SMBus ring buffer was out of sync.\n4. Max payload size is immediately reflected in the internal register when the value is changed.\n5. Wait for transition from Recovery when VDM packet forwarding is completed.\n6. Fixed to resume Write process after NAND Timeout recovery process.\n7. Set OACS bit10 to 1 to remove support of Lockdown on the in-band interface.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "20bf714b8e559377da3eab75736f36b9641946091085d1475a770d95de77f284",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "version": "3.0.4",
      "release_id": "8T6F8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-16T12:34:15Z",
      "released": "2025-05-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13259395M/1/Express-Flash-PCIe-SSD_Firmware_8T6F8_WN64_3.0.4_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8T6F8",
      "size": 29998824,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "revision_history": "Fixes:  \n\n1. When the reference clock is turned off after a PERET# assertion interrupt or a reference clock off interrupt, the CPU never accesses the MAC register until the PIPE clock is restored after PERST# de-assertion.\n2. PHY reset during Hot Reset or Link Disabled is not mandatory, so this process can be skipped. This measure shortens the transition time from Detect to Polling.Active from 70 ms to about 10 ms.\n3. Add flag to prevent DRAM Self Refresh from being triggered.\n4. Once a specific Block has been marked as a bad block that is not to be used, an erase error on the bad block will not cause the Block Erase operation to fail.\n5. The drive FW is modified to suspend the DMAC operation by the drive internal CPU for snapshot saving during the Low power transition.\n6. Fix the Max PE Cycle values mismatch issue for MU 12TB and RI 30TB\n\nEnhancements:  \nN/A"
    },
    {
      "id": "7d93b47a9d1b92fb19afd5ae11efa61fdc5a6d79b95659c25c9029fdba7db904",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.3",
      "release_id": "K1JTM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-13T21:13:35Z",
      "released": "2025-05-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13253883M/1/Express-Flash-PCIe-SSD_Firmware_K1JTM_WN64_2.0.3_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K1JTM",
      "size": 29789880,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n\n1. When the reference clock is turned off after a PERET# assertion interrupt or a reference clock off interrupt, the CPU never accesses the MAC register until the PIPE clock is restored after PERST# de-assertion.\n2. PHY reset during Hot Reset or Link Disabled is not mandatory, so this process can be skipped. This measure shortens the transition time from Detect to Polling.Active from 70 ms to about 10 ms.\n3. Add flag to prevent DRAM Self Refresh from being triggered.\n4. Once a specific Block has been marked as a bad block that is not to be used, an erase error on the bad block will not cause the Block Erase operation to fail.\n5. The drive FW is modified to suspend the DMAC operation by the drive internal CPU for snapshot saving during the Low power transition.\n6. Fix the Max PE Cycle values mismatch issue for MU 12TB and RI 30TB\n\nEnhancements:  \nN/A"
    },
    {
      "id": "e304b4a3afc9985ef42898953bbb4c4c2209d80b9c683042b9eca3daf720a4c2",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "version": "3.1.3",
      "release_id": "JTTYW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T17:47:50Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674733M/1/Express-Flash-PCIe-SSD_Firmware_JTTYW_WN64_3.1.3_A06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTTYW",
      "size": 19213864,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "e3a57703641508d75951c269b891d60af16ef1102477a7610d5e07c6cb16ef3e",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "version": "1.1.1",
      "release_id": "28J8R",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T16:27:47Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674461M/1/Express-Flash-PCIe-SSD_Firmware_28J8R_WN64_1.1.1_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=28J8R",
      "size": 19207336,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    }
  ]
}
