  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "xe9780l",
  "name": "XE9780L",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XE9780L Recommended Updates",
  "filter": "recommended",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 4,
      "rss": "/xe9780l/urgent/rss.xml",
      "api": "/api/xe9780l/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 7,
      "rss": "/xe9780l/recommended/rss.xml",
      "api": "/api/xe9780l/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 11,
      "rss": "/xe9780l/optional/rss.xml",
      "api": "/api/xe9780l/optional"
    },
    {
      "slug": "accelerators",
      "label": "Accelerators",
      "count": 2,
      "rss": "/xe9780l/accelerators/rss.xml",
      "api": "/api/xe9780l/accelerators"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xe9780l/bios/rss.xml",
      "api": "/api/xe9780l/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 2,
      "rss": "/xe9780l/boss/rss.xml",
      "api": "/api/xe9780l/boss"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/xe9780l/diagnostics/rss.xml",
      "api": "/api/xe9780l/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xe9780l/drivers-for-os-deployment/rss.xml",
      "api": "/api/xe9780l/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 4,
      "rss": "/xe9780l/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xe9780l/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xe9780l/firmware/rss.xml",
      "api": "/api/xe9780l/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xe9780l/idrac/rss.xml",
      "api": "/api/xe9780l/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 6,
      "rss": "/xe9780l/network/rss.xml",
      "api": "/api/xe9780l/network"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/xe9780l/security/rss.xml",
      "api": "/api/xe9780l/security"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/xe9780l/systems-management/rss.xml",
      "api": "/api/xe9780l/systems-management"
    }
  ],
  "count": 7,
  "updates": [
    {
      "id": "0977dfbae8a40a6e966730b9138c338cd5e985d9f63aa6ac5dd14dcf8700cee4",
      "name": "iDRAC 1.30.65.51",
      "version": "1.30.65.51",
      "release_id": "C21YH",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-06T13:39:20Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213660M/1/iDRAC-with-Lifecycle-Controller_Firmware_C21YH_WN64_1.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C21YH",
      "size": 357946640,
      "reboot_required": false,
      "description": "iDRAC 1.30.65.51",
      "revision_history": "Fixes\n- Fixed the issue where Serbia was missing from the country code list in the iDRAC SSL/TLS CSR interface.\n- Fixed the issue where iDRAC 1.30.40.51 returns HTTP 400 when accessing Web GUI via FQDN despite HostHeaderCheck being disabled.\n- Fixed the issue where iDRAC time never reverts to RTC if NTP is unavailable.\n- Fixed the issue where SWC9048 error message appears when trying to launch iDRAC IP from UI after updating iDRAC firmware with FIPS enabled.\n- Fixed the issue where SystemCurrentCapLimit and SystemCurrentCapSetting options were missing in racadm get/set system.ServerPwr output while GridCurrentCapLimit settings were exposed.\n- Fixed the issue where STOR090 error occurred when failing to import OMEnt template and SCP when Dedicated HotSpare is present on PERC H965i.\n- Fixed the issue where iDRAC10 SCP export command fails via RACADM for iDRAC firmware version 1.30.40.51.\n- Fixed the issue where GPU Temperature Probe Readings were missing in SNMP and ProbeStatus appeared in unknown state after upgrading to iDRAC 1.30.40.51.\n- Fixed the issue where fans were spinning at 100% when system idle on PowerEdge XE9785 with AMD Pensando Pollara 400 AI Network Interface Card (NIC).\n\n\nEnhancements:\n- Added filter options in iDRAC for SAS address.\n- Fixed the issue where banner for functional pages was still observed when system is in lockdown mode.\n- Added Redfish support to delete AD/LDAP certificates.\n- Populated Redfish Volume Identifiers with durable identifier for PERC RAID virtual disks.\n- Added support to Redfish action EventService.SubmitTestEvent to send test events to Server-Sent Events.\n- Added Redfish support to retrieve configuration preview results for a Job ID.\n- Added Redfish support to reset Storage Controller to defaults.\n- Updated battery page and rollup status design.\n- Added the ability to mount virtual images from S3 for iDRAC.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification.\n- Improved Redfish error messaging for BootSourceOverride failure in iDRAC10.\n- Added OpenID Connect with Azure Entra ID support.\n- Added low privilege iDRAC Operator role.\n- Enabled email alerts for thermal-related GPU/TMP events.\n- Added SMTP modern authentication (OAuth2) support.\n- Enabled email alerts for critical PCI errors (PCI3039/PCI3040) in iDRAC10.\n- Added iDRAC10 BIOS Console Log Retention for serviceability.\n- Added block-level erase and cryptographic validation for iDRAC partitions in SystemErase.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero-Touch Bootstrap.\n- Added support for SID/OPAL/PSID drive status property.\n- Enabled Full APO (Automatic Power On) support for FullPowerReset.\n- Added fan board page health rollup into overall system health.\n- Fixed iDRAC delay in MEM message logging that caused incorrect event ordering.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message.\n- Aligned MultipartUpload ApplyTime behavior with SimpleUpdate (OnStartUpdateRequest).\n- Added BIN Catalog update support.\n- Added native iDRAC10 support for Open Telemetry (OTEL) metric streaming.\n- Added Component-Level Firmware Update and Discoverability via Redfish.\n- Added support for custom HTTP ports for InstallFromRepository via iDRAC UI, Redfish, and RACADM.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior.\n- Added iDRAC support for controlling the SMA_OUT source select.\n- Added support in iDRAC to control the timing module Write_en pin and timing module reset pin with host control via Redfish.\n- Enabled PSU firmware update when single PSU is installed.\n- Added iDRAC CMP V2 support on PowerEdge XR8720T.\n- Added iDRAC uptime to sysinfo.\n- Enhanced iDRAC10 UI usability with VLAN placement, search/filter"
    },
    {
      "id": "1946160ed0d0cb3359a20dfca14e8078ecac5f014fd8979c0efcaa3a71e82245",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "version": "1.1.0",
      "release_id": "4WN4V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-23T16:20:58Z",
      "released": "2026-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14428501M/2/Express-Flash-PCIe-SSD_Firmware_4WN4V_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4WN4V",
      "size": 34529136,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n1. Modified the FW to track second level read recovery triggers.\n2. Developed a firmware fix to add separate queues in the CPU coupled memory to monitor and control the flow of push \u0026 pop entries in the linked list to eliminate any possibility of unexpected concurrent accesses. A dedicated CPU is used for this solution to minimize performance impact.\n3. Modified the FW to set the pointer value to the designated structured memory area.\n4. Updated the firmware to optimize internal operations under this back-to-back power cycle scenario to properly manage APL interrupt.\n5. Updated the firmware to check the thermal throttling stage and manage the resource allocation appropriately before the initiating APL handling.\n6. Enhanced the firmware to handle the back-to-back PERST# operations to ensure that no transitions are missed.\n7. Updated the firmware to increase the PCIe bridge timeout to 1ms\n\nEnhancements:  \n1. Updated the FW to increase the CAP.TO value to 30 seconds for 9550 product family\n2. Updated the Firmware to correct the eye measurement algorithm to appropriately handle PCIe errors conditions.\n3. Enhanced the firmware to optimize folding operations under these specific workloads to improve performance consistency.\n4. Updated the firmware to keep the activity LED on when the host disables the controller (CC.EN=0)"
    },
    {
      "id": "1c15a6bd8bad2c84f474d94ef46dfe7a26fc9bfea3cf34d5901f6fdb59a35926",
      "name": "Firmware for the Nvidia HGX B300 NVL8 Partner-Cooled Baseboard Assembly - Non-Rollback Protected",
      "version": "20.26.06.16",
      "release_id": "TK3RF",
      "category": "Accelerators",
      "category_slug": "accelerators",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-06-21T20:22:48Z",
      "released": "2026-06-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14688881M/1/Accelerators_Firmware_TK3RF_WN64_20.26.06.16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TK3RF",
      "size": 107477960,
      "reboot_required": true,
      "description": "Firmware versions\n===================\nVersion 20.26.06.16 - FW 1.5.10\n\nERoT                        01.04.0055.0000_n04\nFPGA                        1.54\nHMC                         B3-2602-05.0\nGPU VBIOS                   97.10.7E.00.01\nSMA GPU                     0004.00.0272.0000\nConnectX-7 NVSwitch Bridge  28.48.1132\nNVSwitch                    35_2014_5112\nConnectX-8 PCIe Switch      40.48.1132\nSMA ConnectX-8              0011.00.0281.0000",
      "revision_history": "New Feature Summary \n===================\n- None\n\nFixes in FW 1.5.10\n===================\n- Pending Nvidia Documentation\n\nFixes included from FW 1.5.00\n=============================\n- Pending Nvidia Documentation\n\nKnown Issues\n===================\n- GPU assembly firmware activation after updating needs to be done through a physical AC cycle or through a Redfish initiated Virtual AC Cycle\n- ConnectX-8 firmware update as part of the GPU assembly firmware update might fail.  Power cycle and apply the firmware update."
    },
    {
      "id": "0a9060b991543af7de3316df633f402c5a728b23f7168689594f971d6b77c7e9",
      "name": "Firmware for the Nvidia HGX B200 8-GPU Baseboard Assembly Partner-Cooled - Non-Rollback Protected",
      "version": "20.26.06.16",
      "release_id": "K27DY",
      "category": "Accelerators",
      "category_slug": "accelerators",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-06-21T19:51:36Z",
      "released": "2026-06-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14688848M/1/Accelerators_Firmware_K27DY_WN64_20.26.06.16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K27DY",
      "size": 111963944,
      "reboot_required": true,
      "description": "Firmware versions\n===================\nVersion 20.26.06.16 - FW 1.5.10\n\nERoT           01.04.0055.0000_n04\nFPGA           1.A3\nHMC            26.04-1-ga38\nGPU VBIOS      97.00.FA.00.02\nNVSwitchBridge 28.48.1132\nNVSwitch       35_2014_5112\nRetimer        2.20.20",
      "revision_history": "New Feature Summary \n===================\n- None\n\nFixes in FW 1.5.10\n===================\n- Pending Nvidia documentation\n\nFixes included from FW 1.5.00\n=============================\n- Pending Nvidia documentation\n\nKnown Issues\n===================\n- GPU assembly firmware activation after updating needs to be done through a physical AC cycle or through a Redfish initiated Virtual AC Cycle\n- iDRAC may record \"HGX_NVSWITCH_1 NVLink_1\" \"LinkDown\" events if the GPU is reset before the NVSwitch during a system reset.  This is expected and can be ignored.\n- HMC Event Logs may record events such as GPU_SXM_X OCP_WR_ERR_INT at power up.  These events can be ignored.\n- HMC Event Logs may record events such as GPU_SXM_X Driver, FDR Storage at power down.  These events can be ignored."
    },
    {
      "id": "11627fb16dae8be6533ae44611508823df7dfc7d630b3da2e026012a1e143926",
      "name": "Dell Express Flash NVMe PCIe SSD 7600 U.2 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "VJXKC",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-09T04:07:55Z",
      "released": "2026-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14057449M/1/Express-Flash-PCIe-SSD_Firmware_VJXKC_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJXKC",
      "size": 30405520,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7600 U.2 ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any Linux OS. Either use Windows, or iDRAC for FW update. - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "1cbc459f0744e5fb8ad6a5e5e304a69f2938912881e018975e4acfd1ec7e8f1c",
      "name": "eBOSS-N1 Firmware",
      "version": "2.2.13.2037",
      "release_id": "XNDVG",
      "category": "BOSS",
      "category_slug": "boss",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-08T07:27:14Z",
      "released": "2025-08-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13476158M/1/BOSS_Firmware_XNDVG_WN64_2.2.13.2037_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XNDVG",
      "size": 18372408,
      "reboot_required": true,
      "description": "17G BOSS-N1 DC-MHS Package Version 2.2.13.2037",
      "revision_history": "Fixes - Yes\nEnhancements - Yes , please refer the release notes for more details"
    },
    {
      "id": "83b88f31094d8aea6081e8f5d8be31b03926885fae8fc69746185d4d3594fffd",
      "name": "Intel NIC Drivers, Release Version 30.0, for Windows 64-bit Operating Systems",
      "version": "30.0.0.0",
      "release_id": "HCXF3",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2025-06-20T09:32:48Z",
      "released": "2025-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12597518M/3/Network_Driver_HCXF3_WN64_30.0.0.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HCXF3",
      "size": 46928304,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel (R) NIC Drivers on Windows Server 2022, and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "Fixes/Enhancements\n==================\n\n  Previous release: N/A\n  Current release:  30.0\n  \n  Please go to Intel's support website and download the release notes version 30.0 for details about the fixes and enhancements:\n  https://www.intel.com/content/www/us/en/download/19622/intel-ethernet-product-release-notes.html\n\n\nKnown Issues\n=============\n\n  1. When installing virtual function (VF) drivers using the Dell Update Package (DUP) on Virtual Machines (VMs), \n     users may encounter a \"Runtime error code (1) update failure\" message. This error is cosmetic and does not impact the installation of the VF drivers. A fix for this issue will be included in future releases. {333797}"
    }
  ]
}