  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "xe9685l",
  "name": "XE9685L",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XE9685L Express Flash PCIe SSD Updates",
  "filter": "express-flash-pcie-ssd",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 9,
      "rss": "/xe9685l/urgent/rss.xml",
      "api": "/api/xe9685l/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 13,
      "rss": "/xe9685l/recommended/rss.xml",
      "api": "/api/xe9685l/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 12,
      "rss": "/xe9685l/optional/rss.xml",
      "api": "/api/xe9685l/optional"
    },
    {
      "slug": "accelerators",
      "label": "Accelerators",
      "count": 1,
      "rss": "/xe9685l/accelerators/rss.xml",
      "api": "/api/xe9685l/accelerators"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xe9685l/bios/rss.xml",
      "api": "/api/xe9685l/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/xe9685l/boss/rss.xml",
      "api": "/api/xe9685l/boss"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xe9685l/drivers-for-os-deployment/rss.xml",
      "api": "/api/xe9685l/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 19,
      "rss": "/xe9685l/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xe9685l/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xe9685l/firmware/rss.xml",
      "api": "/api/xe9685l/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xe9685l/idrac/rss.xml",
      "api": "/api/xe9685l/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 8,
      "rss": "/xe9685l/network/rss.xml",
      "api": "/api/xe9685l/network"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 1,
      "rss": "/xe9685l/systems-management/rss.xml",
      "api": "/api/xe9685l/systems-management"
    }
  ],
  "count": 19,
  "updates": [
    {
      "id": "48c5469a4a346a44cc4729143b3df57c3c9d8a12638878a02ea6a9cd86561b51",
      "name": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "version": "1.0.2",
      "release_id": "1W7Y8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-22T19:07:37Z",
      "released": "2026-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568456M/2/Express-Flash-PCIe-SSD_Firmware_1W7Y8_WN64_1.0.2_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1W7Y8",
      "size": 35321280,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected SPDM data offset used when calculating the SPDM manifest.\n2. Enhanced NVMe-MI logic.\n3. Fixed NVMe-MI message response delays; reponses to all NVMe-MI messages within a 100ms timeout period.\n4. Restrict SMBus communication to when the drive is ready to service MCTP/Basic.\n\nEnhancements:\n\n1. Enhanced MCTP processing over SMBus while SMBus is in a reset state.\n2. DUP support for ARM platforms added.\n3. DUP support updated for PERC 12 and 13."
    },
    {
      "id": "be2552182a26eb88759d7217cc5aefc2cd96994a7322cfad3004048d11f48723",
      "name": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "version": "1.0.2",
      "release_id": "HN0CY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-19T21:48:29Z",
      "released": "2026-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568517M/1/Express-Flash-PCIe-SSD_Firmware_HN0CY_WN64_1.0.2_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN0CY",
      "size": 29331112,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "revision_history": "Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software)."
    },
    {
      "id": "f0477d83411396c5aa41dc093b6f87c193db3f8a49b4276a1d829a96500bfa3e",
      "name": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.2",
      "release_id": "17R29",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-05-12T10:07:15Z",
      "released": "2026-05-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14538090M/1/Express-Flash-PCIe-SSD_Firmware_17R29_WN64_2.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17R29",
      "size": 27203048,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Upon detecting SMBDAT is stuck in low state, a bus clear is performed to release the low state.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "78c2385f78e01efa51a8798695530f7a9d445ab7b40872bfb2d691b7e9e3b663",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.5",
      "release_id": "KRHCN",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-05-06T15:41:31Z",
      "released": "2026-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14515537M/1/Express-Flash-PCIe-SSD_Firmware_KRHCN_WN64_2.0.5_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KRHCN",
      "size": 27415688,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release"
    },
    {
      "id": "2576d421636e87b519086721087196201ac74ebd37755dce4f70eb579e503d8d",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release Maintenance Firmware",
      "version": "1.3.1",
      "release_id": "N78NP",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-03T19:47:31Z",
      "released": "2026-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14259015M/1/Express-Flash-PCIe-SSD_Firmware_N78NP_WN64_1.3.1_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N78NP",
      "size": 27170488,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release - Maintenance Firmware",
      "revision_history": "Fixes:  \n\n1. Improved the firmware to ensure internal PCIe register access is done according to the specification.\n2. Updated the firmware to add SCL detection/protection\n3. Improved firmware to detect the noise on power rail.\n4. Improved firmware to add detection/protection for incomplete Host-Initiated Data Transfer\n5. Improved firmware to add detection/protection for drive Initialization with Poor PCIe Signal Integrity\n6. Improved firmware to add detection and initiate rest/recovery operation to the power management controller upon power on.\n7. Updated the firmware to prevent the deadlock scenario while extended Host Idle Time (no SSD device I/O)\n8. Updated the firmware to Enable PCIe relaxed ordering\n\nEnhancements:  \nN/A"
    },
    {
      "id": "d2e853f3f5a847f2ac69e20f6a50ee0c8c13d7f51ebea7fce622736a421738ac",
      "name": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release",
      "version": "1.3.0",
      "release_id": "VNYK2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-01-08T16:07:20Z",
      "released": "2025-11-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14055051M/1/Express-Flash-PCIe-SSD_Firmware_VNYK2_WN64_1.3.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VNYK2",
      "size": 32458088,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "d7118a4011a988e2e951915d1cc298925ca524ddf11d30cbbcda0b4011e70320",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.4.0",
      "release_id": "TVCWT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-07-11T04:31:50Z",
      "released": "2025-07-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13369867M/1/Express-Flash-PCIe-SSD_Firmware_TVCWT_WN64_1.4.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TVCWT",
      "size": 29064896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo be added"
    },
    {
      "id": "94586f99bddb6d07e51ebf78479fa5de5fb353777dec7e7bb0b73c704b3c21bf",
      "name": "Dell Datacenter NVME RI AGN ISE",
      "version": "1.1.1",
      "release_id": "XMFKX",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:50:32Z",
      "released": "2024-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12037085M/2/Express-Flash-PCIe-SSD_Firmware_XMFKX_WN64_1.1.1_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XMFKX",
      "size": 30415680,
      "reboot_required": false,
      "description": "Dell Datacenter NVME RI AGN ISE",
      "revision_history": "Fixes:\n\n1. Updated DUP framework for 17G server platforms."
    },
    {
      "id": "7b5443856ba19be3fec98045af7c451979d66ce96d52fa3076856936318d3249",
      "name": "Dell Datacenter NVMe RI AG ISE",
      "version": "1.1.0",
      "release_id": "TDGKY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-06-20T11:09:41Z",
      "released": "2024-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12324309M/2/Express-Flash-PCIe-SSD_Firmware_TDGKY_WN64_1.1.0_A02_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TDGKY",
      "size": 31845152,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE",
      "revision_history": "Fixes:\n\nEnhancements:\n\n1. Implementation of the latest Eye Opening Measurement specfication (TP4119a).\n2. Enable support for Eye Opening Measurement (PCLMT) Tool version 3.2.7."
    },
    {
      "id": "e15c5dbca1aa92bdad00cf199545ec3662def62b46bfe73a9eca54b61a1de3e4",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "version": "3.0.2",
      "release_id": "J0Y48",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T10:59:00Z",
      "released": "2025-03-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12655574M/2/Express-Flash-PCIe-SSD_Firmware_J0Y48_WN64_3.0.2_A02_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J0Y48",
      "size": 30042840,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "revision_history": "Fixes:  \nTo Be added\n\nEnhancements:  \nTo Be added"
    },
    {
      "id": "1a8d0cae34f34673f3b4b00e11c9afb0dd6c336159ff4731f389b80feed0f007",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 ISE Firmware Release",
      "version": "1.0.2",
      "release_id": "NHM72",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-13T00:49:07Z",
      "released": "2025-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12850528M/1/Express-Flash-PCIe-SSD_Firmware_NHM72_WN64_1.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NHM72",
      "size": 30929456,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any RHEL and Ubuntu OS. Either use Windows SLES or iDRAC for FW update - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "7be90932a9eca915194db12b4b54c6e2d1dfaf50ecc4c79c27b1761682ea45d0",
      "name": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "version": "2.5.0",
      "release_id": "4P5K1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-07-03T13:05:39Z",
      "released": "2024-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11804735M/1/Express-Flash-PCIe-SSD_Firmware_4P5K1_WN64_2.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4P5K1",
      "size": 7724464,
      "reboot_required": false,
      "description": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "revision_history": "Fixes:\n\n- FW introduces multiple fixes and enhancements."
    },
    {
      "id": "e304b4a3afc9985ef42898953bbb4c4c2209d80b9c683042b9eca3daf720a4c2",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "version": "3.1.3",
      "release_id": "JTTYW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T17:47:50Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674733M/1/Express-Flash-PCIe-SSD_Firmware_JTTYW_WN64_3.1.3_A06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTTYW",
      "size": 19213864,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "e3a57703641508d75951c269b891d60af16ef1102477a7610d5e07c6cb16ef3e",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "version": "1.1.1",
      "release_id": "28J8R",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T16:27:47Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674461M/1/Express-Flash-PCIe-SSD_Firmware_28J8R_WN64_1.1.1_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=28J8R",
      "size": 19207336,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "011cb51c31d6a54ec99d1838077c9124306b4910ee57754ecff998648108b714",
      "name": "SK Hynix PE80X0 SP M.2 ISE FW 1.3.0 version for model numbers HFS480GDC8X099N, HFS800GDC8X088N, HFS960GDC8X099N, HFS1T9GDC8X099N",
      "version": "1.3.0",
      "release_id": "R2TTT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-03T18:43:23Z",
      "released": "2024-05-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11576366M/1/Express-Flash-PCIe-SSD_Firmware_R2TTT_WN64_1.3.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R2TTT",
      "size": 9310536,
      "reboot_required": false,
      "description": "This release contains the SK Hynix PE80X0 ISE FW 1.3.0 version for model number(s) HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X088N, HFS480GDC8X096N.",
      "revision_history": "Fixes: \n\n- Under certain conditions, the drive may become unresponsive causing the BOSS (Boot Optimized Storage Card) virtual LUN to go offline."
    },
    {
      "id": "006c7f97b61850b4e18ebe89988c181f485be2e0b9b256d6c63ef1a257aad711",
      "name": "SK Hynix PE80X0 M.2 Opal/SED drive firmware 1.3.0 for model numbers HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X096N, HFS480GDC8X096N.",
      "version": "1.3.0",
      "release_id": "4NH4W",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-03T18:09:57Z",
      "released": "2024-05-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11576312M/1/Express-Flash-PCIe-SSD_Firmware_4NH4W_WN64_1.3.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4NH4W",
      "size": 9530648,
      "reboot_required": false,
      "description": "This release contains FW version 1.3.0 for SK Hynix PE80X0 M.2 Opal/SED drives HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X096N, HFS480GDC8X096N.",
      "revision_history": "Fixes: \n\n- Under certain conditions, the drive may become unresponsive causing the BOSS (Boot Optimized Storage Card) virtual LUN to go offline."
    },
    {
      "id": "11650d81b07b4ae4af9c7f55fe1767678d5db6f81209a32e256b0e098f2c701f",
      "name": "Dell EC NVMe SED 7450 RI M.2 80, MTFDKBA480TFR, MTFDKBA960TFR",
      "version": "2.1.0",
      "release_id": "YYYRJ",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-12T11:22:12Z",
      "released": "2024-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11363365M/1/Express-Flash-PCIe-SSD_Firmware_YYYRJ_WN64_2.1.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YYYRJ",
      "size": 8050312,
      "reboot_required": false,
      "description": "Dell EC NVMe SED 7450 RI M.2 80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes: \n\n- Firmware release includes bug fixes and enhancements added since the most recent prior firmware release 2.0.0."
    },
    {
      "id": "8b797d2033075b5fcc501cb105ea8dce3857c0f835f3ca625c073e44b6a5813c",
      "name": "Hynix 1.1.0 FW for PE9010 NVMe drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "version": "1.1.0",
      "release_id": "CDKNW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-05T17:47:40Z",
      "released": "2024-01-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11092654M/1/Express-Flash-PCIe-SSD_Firmware_CDKNW_WN64_1.1.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CDKNW",
      "size": 12225320,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.1.0 for Hynix PE9010 NVMe SSD drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "revision_history": "FW to provide performance improvements."
    }
  ]
}