  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "xe9680",
  "name": "XE9680",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XE9680 Urgent Updates",
  "filter": "urgent",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 15,
      "rss": "/xe9680/urgent/rss.xml",
      "api": "/api/xe9680/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 45,
      "rss": "/xe9680/recommended/rss.xml",
      "api": "/api/xe9680/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 32,
      "rss": "/xe9680/optional/rss.xml",
      "api": "/api/xe9680/optional"
    },
    {
      "slug": "accelerators",
      "label": "Accelerators",
      "count": 8,
      "rss": "/xe9680/accelerators/rss.xml",
      "api": "/api/xe9680/accelerators"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xe9680/bios/rss.xml",
      "api": "/api/xe9680/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/xe9680/boss/rss.xml",
      "api": "/api/xe9680/boss"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/xe9680/diagnostics/rss.xml",
      "api": "/api/xe9680/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xe9680/drivers-for-os-deployment/rss.xml",
      "api": "/api/xe9680/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 48,
      "rss": "/xe9680/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xe9680/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xe9680/firmware/rss.xml",
      "api": "/api/xe9680/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xe9680/idrac/rss.xml",
      "api": "/api/xe9680/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 13,
      "rss": "/xe9680/network/rss.xml",
      "api": "/api/xe9680/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 6,
      "rss": "/xe9680/sas-drive/rss.xml",
      "api": "/api/xe9680/sas-drive"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 3,
      "rss": "/xe9680/sas-raid/rss.xml",
      "api": "/api/xe9680/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/xe9680/security/rss.xml",
      "api": "/api/xe9680/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 5,
      "rss": "/xe9680/serial-ata/rss.xml",
      "api": "/api/xe9680/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/xe9680/systems-management/rss.xml",
      "api": "/api/xe9680/systems-management"
    }
  ],
  "count": 15,
  "updates": [
    {
      "id": "3c42a5d5d6593d1bb6afbb03bfc0943458d93671a8a9b79d91ec42193d56871e",
      "name": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "GF3PY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-11-03T17:31:07Z",
      "released": "2026-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199882M/1/Express-Flash-PCIe-SSD_Firmware_GF3PY_WN64_1.5.0_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GF3PY",
      "size": 38306408,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release"
    },
    {
      "id": "a2c0b63fa50d2f9175300cc8041608e02ff774947b5fbbbbe5ec847934e57b8f",
      "name": "Dell Server PowerEdge BIOS Version 2.12.2",
      "version": "2.12.2",
      "release_id": "VTDD9",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-10-19T10:46:49Z",
      "released": "2026-10-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15144333M/1/BIOS_VTDD9_WN64_2.12.2.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VTDD9",
      "size": 45307816,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced feature sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Fixes:\n- N/A.\n\nEnhancements:\n- Updated the followings:\n  * Intel processor and memory reference codes to IPU 2026.4\n  * Intel processor microcode to version 0x690 in the 4th Generation Intel Xeon Scalable Processors Family.\n  * Intel processor microcode to version 0x300 in the 5th Generation Intel Xeon Scalable Processors Family.\n- This release contains security fixes that address one or more vulnerabilities. Dell recommends that you run the most recent available version of the software and apply any security updates at the earliest opportunity. Upon completion of coordinated vulnerability disclosure activities, Dell will publish a Dell Security Advisory (DSA) providing additional details about the vulnerabilities and associated security updates. Customers are encouraged to subscribe to Dell Security Advisories to receive notifications when advisories are published."
    },
    {
      "id": "2784cac0b8b58ea70ad630208898d6eb97e9b03ca201d3538f7cdf540045f1b2",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N",
      "version": "1.3.1",
      "release_id": "VMDWF",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:48Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652186M/3/Express-Flash-PCIe-SSD_Firmware_VMDWF_WN64_1.3.1_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VMDWF",
      "size": 28699000,
      "reboot_required": true,
      "description": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N.",
      "revision_history": "Fixes: \n\nFW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "48c5469a4a346a44cc4729143b3df57c3c9d8a12638878a02ea6a9cd86561b51",
      "name": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "version": "1.0.2",
      "release_id": "1W7Y8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-22T19:07:37Z",
      "released": "2026-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568456M/2/Express-Flash-PCIe-SSD_Firmware_1W7Y8_WN64_1.0.2_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1W7Y8",
      "size": 35321280,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected SPDM data offset used when calculating the SPDM manifest.\n2. Enhanced NVMe-MI logic.\n3. Fixed NVMe-MI message response delays; reponses to all NVMe-MI messages within a 100ms timeout period.\n4. Restrict SMBus communication to when the drive is ready to service MCTP/Basic.\n\nEnhancements:\n\n1. Enhanced MCTP processing over SMBus while SMBus is in a reset state.\n2. DUP support for ARM platforms added.\n3. DUP support updated for PERC 12 and 13."
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "be2552182a26eb88759d7217cc5aefc2cd96994a7322cfad3004048d11f48723",
      "name": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "version": "1.0.2",
      "release_id": "HN0CY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-19T21:48:29Z",
      "released": "2026-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568517M/1/Express-Flash-PCIe-SSD_Firmware_HN0CY_WN64_1.0.2_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN0CY",
      "size": 29331112,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "revision_history": "Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software)."
    },
    {
      "id": "8c8ef71dbb44065fb7602356e71941c035af821216ed9f1836d7039756455cc3",
      "name": "BOSS-N1 Monolithic Firmware",
      "version": "2.1.13.2038",
      "release_id": "WGYK7",
      "category": "BOSS",
      "category_slug": "boss",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-04-15T07:15:07Z",
      "released": "2026-04-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14432031M/3/BOSS_Firmware_WGYK7_WN64_2.1.13.2038_A07_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WGYK7",
      "size": 23270496,
      "reboot_required": true,
      "description": "BOSS-N1 Monolithic Package Version 2.1.13.2038"
    },
    {
      "id": "f7de63ece5daeac08267a48d8bc14fe3582ec54363070acb789f8ff1b32bd6df",
      "name": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "version": "2.0.5",
      "release_id": "34VN7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-18T15:31:12Z",
      "released": "2026-02-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14320085M/1/Express-Flash-PCIe-SSD_Firmware_34VN7_WN64_2.0.5_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=34VN7",
      "size": 27738144,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "revision_history": "N/A"
    },
    {
      "id": "dcbacd995c2a5a32379d174df93ed1431e6552d5a2d2ef0e098973eab0e859ff",
      "name": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release",
      "version": "1.7.0",
      "release_id": "D6RJK",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-10T13:43:02Z",
      "released": "2026-03-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14284736M/1/Express-Flash-PCIe-SSD_Firmware_D6RJK_WN64_1.7.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D6RJK",
      "size": 26508840,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release"
    },
    {
      "id": "2576d421636e87b519086721087196201ac74ebd37755dce4f70eb579e503d8d",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release Maintenance Firmware",
      "version": "1.3.1",
      "release_id": "N78NP",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-03T19:47:31Z",
      "released": "2026-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14259015M/1/Express-Flash-PCIe-SSD_Firmware_N78NP_WN64_1.3.1_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N78NP",
      "size": 27170488,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release - Maintenance Firmware",
      "revision_history": "Fixes:  \n\n1. Improved the firmware to ensure internal PCIe register access is done according to the specification.\n2. Updated the firmware to add SCL detection/protection\n3. Improved firmware to detect the noise on power rail.\n4. Improved firmware to add detection/protection for incomplete Host-Initiated Data Transfer\n5. Improved firmware to add detection/protection for drive Initialization with Poor PCIe Signal Integrity\n6. Improved firmware to add detection and initiate rest/recovery operation to the power management controller upon power on.\n7. Updated the firmware to prevent the deadlock scenario while extended Host Idle Time (no SSD device I/O)\n8. Updated the firmware to Enable PCIe relaxed ordering\n\nEnhancements:  \nN/A"
    },
    {
      "id": "b3756f56e76fb6fdf6d53d9bc0bb41fa37aaf9ec858ba959301334044cd538e7",
      "name": "DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR",
      "version": "DL7C",
      "release_id": "VJPKG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-08-19T07:07:49Z",
      "released": "2025-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12600340M/4/Serial-ATA_Firmware_VJPKG_WN64_DL7C_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJPKG",
      "size": 22988728,
      "reboot_required": false,
      "description": "This is a firmware release for DELLSLDM Youngsville-RR  DL7C firmware for Model number(s) SSDSC2KB240GZR, SSDSC2KB480GZR, SSDSC2KB960GZR, SSDSC2KB019TZR, SSDSC2KB038TZR, SSDSC2KB076TZR, SSDSCKKB240GZR, SSDSCKKB480GZR,SSDSC2KG480GZR, SSDSC2KG960GZR, SSDSC2KG019TZR, SSDSC2KG038TZR",
      "revision_history": "Issue: During a warm Reboot the YVRR drive may intermittently disappear when connected to the PERC H965i\nFix: DL7C FW now addresses this issue\nIssue: PLI capacitor charge flag not set leads drive to enter disable logical mode\nFix: DL7C FW now addresses this issue"
    },
    {
      "id": "d7118a4011a988e2e951915d1cc298925ca524ddf11d30cbbcda0b4011e70320",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.4.0",
      "release_id": "TVCWT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-07-11T04:31:50Z",
      "released": "2025-07-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13369867M/1/Express-Flash-PCIe-SSD_Firmware_TVCWT_WN64_1.4.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TVCWT",
      "size": 29064896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo be added"
    },
    {
      "id": "011cb51c31d6a54ec99d1838077c9124306b4910ee57754ecff998648108b714",
      "name": "SK Hynix PE80X0 SP M.2 ISE FW 1.3.0 version for model numbers HFS480GDC8X099N, HFS800GDC8X088N, HFS960GDC8X099N, HFS1T9GDC8X099N",
      "version": "1.3.0",
      "release_id": "R2TTT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-03T18:43:23Z",
      "released": "2024-05-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11576366M/1/Express-Flash-PCIe-SSD_Firmware_R2TTT_WN64_1.3.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R2TTT",
      "size": 9310536,
      "reboot_required": false,
      "description": "This release contains the SK Hynix PE80X0 ISE FW 1.3.0 version for model number(s) HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X088N, HFS480GDC8X096N.",
      "revision_history": "Fixes: \n\n- Under certain conditions, the drive may become unresponsive causing the BOSS (Boot Optimized Storage Card) virtual LUN to go offline."
    },
    {
      "id": "006c7f97b61850b4e18ebe89988c181f485be2e0b9b256d6c63ef1a257aad711",
      "name": "SK Hynix PE80X0 M.2 Opal/SED drive firmware 1.3.0 for model numbers HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X096N, HFS480GDC8X096N.",
      "version": "1.3.0",
      "release_id": "4NH4W",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-03T18:09:57Z",
      "released": "2024-05-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11576312M/1/Express-Flash-PCIe-SSD_Firmware_4NH4W_WN64_1.3.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4NH4W",
      "size": 9530648,
      "reboot_required": false,
      "description": "This release contains FW version 1.3.0 for SK Hynix PE80X0 M.2 Opal/SED drives HFS1T9GDC8X096N, HFS960GDC8X096N, HFS800GDC8X096N, HFS480GDC8X096N.",
      "revision_history": "Fixes: \n\n- Under certain conditions, the drive may become unresponsive causing the BOSS (Boot Optimized Storage Card) virtual LUN to go offline."
    },
    {
      "id": "41918bd0bc2e05c6eb1fc65a8c7bb009dceb1291997feccc49bef3b1547fe821",
      "name": "Kioxia BH03 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "version": "BH03",
      "release_id": "C8CVG",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-06-26T17:37:04Z",
      "released": "2023-06-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10247472M/1/SAS-Drive_Firmware_C8CVG_WN64_BH03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C8CVG",
      "size": 12181328,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BH03 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "revision_history": "Following two countermeasures were added to reduce the occurrence probability of PMIC busy issue.\n1.Rationalize PMIC I2C commands.\n2.Reduce PLP Capacity Patrol frequency."
    }
  ]
}