  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "xe8545",
  "name": "XE8545",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XE8545 Updates",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 12,
      "rss": "/xe8545/urgent/rss.xml",
      "api": "/api/xe8545/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 57,
      "rss": "/xe8545/recommended/rss.xml",
      "api": "/api/xe8545/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 37,
      "rss": "/xe8545/optional/rss.xml",
      "api": "/api/xe8545/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xe8545/bios/rss.xml",
      "api": "/api/xe8545/bios"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/xe8545/diagnostics/rss.xml",
      "api": "/api/xe8545/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xe8545/drivers-for-os-deployment/rss.xml",
      "api": "/api/xe8545/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 15,
      "rss": "/xe8545/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xe8545/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xe8545/firmware/rss.xml",
      "api": "/api/xe8545/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xe8545/idrac/rss.xml",
      "api": "/api/xe8545/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 35,
      "rss": "/xe8545/network/rss.xml",
      "api": "/api/xe8545/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 20,
      "rss": "/xe8545/sas-drive/rss.xml",
      "api": "/api/xe8545/sas-drive"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 12,
      "rss": "/xe8545/sas-raid/rss.xml",
      "api": "/api/xe8545/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 16,
      "rss": "/xe8545/serial-ata/rss.xml",
      "api": "/api/xe8545/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/xe8545/systems-management/rss.xml",
      "api": "/api/xe8545/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/xe8545/video/rss.xml",
      "api": "/api/xe8545/video"
    }
  ],
  "count": 106,
  "updates": [
    {
      "id": "329fbb2ee66ab126936903ccef3ff6ee45d20dcd0cd5f2226381227636a412ab",
      "name": "Dell Server XE8545 BIOS version 2.24.0",
      "version": "2.24.0",
      "release_id": "T2F2X",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-11-11T06:19:28Z",
      "released": "2026-11-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15225257M/1/XE8545_BIOS_T2F2X_WN64_2.24.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T2F2X",
      "size": 37736888,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced feature sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Fixes:\n- Fixed an issue causing a UEFI0072 Secure Boot error when the Secure Boot Policy was set to VMware Boot and a device (such as PERC) was updated to firmware signed with the newer 2023 certificate.\n\nEnhancements:\n- Updated the followings:\n        *AMD Family 19h Models 00h-0Fh processor SEV firmware version is updated to 1.58.03.\n        *AMD Family 19h Models 00h-0Fh processor microcode version is updated to\n               - B1: 0x0A0011E1\n               - B2: 0x0A00124E\n- This product release contains security update. Any security fix information will be accessible on the Dell Security Advisories and Notices website."
    },
    {
      "id": "837f52bcdf77c2d14310498f7dd4952e13c37aa4c6fdc01265b9a428e061657d",
      "name": "Dell EMC iDRAC Service Module Installer for OS DUP, v6.2.0.0",
      "version": "6.2.0.0",
      "release_id": "JDJH3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-11-09T07:17:23Z",
      "released": "2026-10-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15095008M/5/Systems-Management_Application_JDJH3_WN64_6.2.0.0_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDJH3",
      "size": 34422592,
      "reboot_required": false,
      "description": "iDRAC Service Module (iSM) is a lightweight software service that better integrates operating system (OS) features with iDRAC and can be installed on Dell PowerEdge 15G and above servers. iSM provides OS-related information to iDRAC and adds capabilities such as Lifecycle Controller log event replication into the OS log, iDRAC SNMP alerts via OS, iDRAC hard reset and remote full Power Cycle. iSM has very little impact on the host processor and smaller memory footprint, thus expanding iDRAC management to the supported host operating systems.",
      "revision_history": "NA"
    },
    {
      "id": "76245d0a584c5ccc82e289fc13f517d6fe16339b10aa85c49a062f45e8a4f53d",
      "name": "DELL System Update, v.2.3.0.2",
      "version": "2.3.0.2",
      "release_id": "RDVR3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-11-06T11:10:35Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213121M/1/Systems-Management_Application_RDVR3_WN64_2.3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RDVR3",
      "size": 30983200,
      "reboot_required": false,
      "description": "DELL System Update (DSU) is a software designed to facilitate the application of updates on various Dell systems. Using DSU you can:\n1.Identify the available updates, select the relevant updates, and deploy the updates on multiple systems.\n2.Maintain consistency in terms of interface and versions across Operating Systems, Repositories, and Systems.",
      "revision_history": "Enhancement :\n\nOS native support with passthrough and rsystemtype iDRAC \n\nFixes :\n\nSecurity Issues"
    },
    {
      "id": "fd0732c1a5436e1e87e2f3b578749cbde7f0ad1acade4f2c68a4395a4ec03d68",
      "name": "iDRAC 7.30.65.51",
      "version": "7.30.65.51",
      "release_id": "77JC4",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-26T15:08:42Z",
      "released": "2026-10-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15169022M/1/iDRAC-with-Lifecycle-Controller_Firmware_77JC4_WN64_7.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=77JC4",
      "size": 244930552,
      "reboot_required": false,
      "description": "The Integrated Dell Remote Access Controller (iDRAC) is designed to make server administrators more productive and improve the overall availability of Dell servers. iDRAC also provides an out-of-band mechanism for configuring the platform, applying firmware updates, saving or restoring a system backup, or deploying an operating system, either by using a GUI or a remote scripting language, such as Redfish or RACADM.",
      "revision_history": "Fixes:\n- Fixes the issue where email alert is not enabled for LCS0009 event on PowerEdge XE8640 systems.\n- Fixes the issue where RAC1195 events for local user account deletion are missing in iDRAC9 releases by instrumenting the user deletion endpoint to generate audit logs.\n- Fixes the issue where Active Directory authentication fails due to DNS Type = ANY by changing the DNS query from T_ANY to T_SRV to comply with RFC8482.\n- Fixes the issue where CPU throttling occurs when PSU power input drops on PowerEdge T550 systems since iDRAC 7.20.30.00 by addressing the power FTR loop issue.\n- Fixes the issue where firmware update notifications on homepage use cached recommended updates by addressing the deletion of lc_validator_output.xml during iDRAC reboot or system erase operation.\n- Fixes the issue where fan failures occur on PowerScale R660 nodes after firmware updates by addressing the timing issue between BIOS updates and fan initialization.\n\nEnhancements:\n- Made Subject Alternative Name (SAN) mandatory for SSL/TLS CSR generation in iDRAC9.\n- Upgraded Poky for iDRAC9 16G.\n- Upgraded kernel to version 6.12.63 for iDRAC9 16G.\n- Added SMTP modern authentication (OAuth2) support for iDRAC9 16G.\n- Added TPM PCR Measurements reporting in Redfish for iDRAC9.\n- Added new option \"LCLOG\" in SystemErase for clearing LC logs without host reboot.\n- Added China Data Sanitization Compliance with Block Erase support on drives via iDRAC for 16G.\n- Leveraged iDRAC Early Video for Services Modernization on 16G.\n- Optimized 16G CPLD Firmware Update for Services Modernization.\n- Implemented correct and reliable Redfish StartUpdate action for 16G.\n- Enabled optional auto deletion of completed/failed iDRAC Jobs for 16G.\n- Enabled CPLD and iDRAC firmware updates with a single iDRAC reboot for 16G.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior for 16G.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message for 16G.\n- Added Leak Warranty Void Warning Message support for iDRAC platforms 16G.\n- Updated OID for SCV replacement certificate on 16G/15G platforms.\n- Added security (firmware) assertions from iDRAC9 to SCV certificate.\n- Added iDRAC persistence and reconciliation capability for SCV Delta Certificate upload synchronization.\n- Enabled email alerts for thermal-related GPU/TMP events for 16G.\n- Enabled iLKM support on PowerEdge XR8620t.\n- Added Microsoft Entra ID (formerly Azure AD) support for OpenID Connect for 16G.\n- Migrated iDRAC9 GUI from AngularJS to Angular Framework for 16G.\n- Addressed Channel Firmware SED integration and stability issues for 16G.\n- Updated Redfish specification and schema for the 16G March release.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification for iDRAC9.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero Touch Bootstrap for 16G.\n- Fixed BootProgress/LastState property value showing as \"OSRunning\" when the server is not booted to the operating system.\n- Improved SEKM key retrieval retry and logging.\n- Added iDRAC uptime to sysinfo for 16G.\n- Added GetBIOSTime functionality and SetBIOSTime handling for unsupported BIOS for 16G.\n- Exposed Redfish APIs for Hardware Configuration Validation control in iDRAC for 16G.\n- Added support for SID/OPAL/PSID drive status property.\n- Added SDPM Battery Inventory and BBU Replacement Behavior for 16G."
    },
    {
      "id": "318fefd2743ce3a042428d9e8d722b8a862af777cc9df710c689ecd125c66516",
      "name": "Broadcom NetXtreme-E Network Device Firmware (Dell) 23.8.1",
      "version": "38.11.91.00",
      "release_id": "H3TR4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-10-13T23:36:18Z",
      "released": "2026-10-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15122845M/1/Network_Firmware_H3TR4_WN64_38.11.91.00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3TR4",
      "size": 84351360,
      "reboot_required": false,
      "description": "This release provides updated network controller firmware for the Broadcom NetXtreme-E devices.   This release should be used with the Broadcom NetXtreme-E 23.8 device drivers."
    },
    {
      "id": "a9017f3140289b317e112d789c28482d6226881bc8dd0e05c58dc4640963ca51",
      "name": "MICRON 5200 RI/ MU SATA \u0026apos;F006\u0026apos; FW for model number(s) MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, MTFDDAK1T9TDN, MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD",
      "version": "F006",
      "release_id": "DJFFV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T13:57:57Z",
      "released": "2026-06-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14570492M/2/Serial-ATA_Firmware_DJFFV_WN64_F006_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DJFFV",
      "size": 26417352,
      "reboot_required": false,
      "description": "This release contains Micron firmware F006 for models MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD, MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, and MTFDDAK1T9TDN for all operating systems.",
      "revision_history": "LogEntryCnt = 65,535 \n- Exit the workload log function directly; no workload log entry is recorded.\nLogEntryCnt = 0 to 65,534\n- Workload log recording continues as originally designed."
    },
    {
      "id": "84424b59e4b03b97dcd05979da85efce26d61c206d7cbf88df0ae2523c8269c6",
      "name": "NVIDIA Mellanox Firmware Release 26.50.10.02 for Dell Customized NVIDIA Mellanox ConnectX-6 LX Ethernet Adapters",
      "version": "26.50.10.02",
      "release_id": "HW6K0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T18:44:16Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15080928M/1/Network_Firmware_HW6K0_WN64_26.50.10.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HW6K0",
      "size": 45977560,
      "reboot_required": true,
      "description": "NVIDIA Mellanox Firmware Release 26.50.10.02 for Dell Customized NVIDIA Mellanox ConnectX-6 LX Ethernet Adapters on Dell 14G and 15G and 16G servers. This release provides continued code optimization to improve performance."
    },
    {
      "id": "67eae8f2063acffdcbb8ee95bc7363b5fea8878c6f66ab0aa041fc7d90293fc9",
      "name": "NVIDIA Mellanox Firmware Release 28.50.10.02 for Dell Customized NVIDIA Mellanox ConnectX-7 NDR Adapters",
      "version": "28.50.10.02",
      "release_id": "CR8PR",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T15:16:21Z",
      "released": "2026-09-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15080360M/1/Network_Firmware_CR8PR_WN64_28.50.10.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CR8PR",
      "size": 77078568,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies FMP Based Update Package to install NVIDIA Mellanox Firmware Release 28.50.10.02 for Dell Customized NVIDIA Mellanox ConnectX-7 NDR Adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "c6f2ad0676741ff665ce9fcf695a0917988e577ea0a3b678a9e83d7902b809cd",
      "name": "NVIDIA Mellanox Firmware Release 22.50.10.02 for Dell Customized NVIDIA Mellanox ConnectX-6 DX Adapters",
      "version": "22.50.10.02",
      "release_id": "40HW6",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T15:06:30Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15080319M/1/Network_Firmware_40HW6_WN64_22.50.10.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=40HW6",
      "size": 46496216,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Dell customized Nvidia Mellanox firmware release 22.50.10.02 on NVIDIA Mellanox ConnectX-6 DX adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "ddd0e2c51b4580eb2778870b68324d237a03ac014aa8e6f1d071efa03f75333c",
      "name": "BOSS-S2 Firmware",
      "version": "2.5.13.4009",
      "release_id": "TTR5R",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-25T07:01:26Z",
      "released": "2023-02-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09232098M/7/SAS-RAID_Firmware_TTR5R_WN64_2.5.13.4009_A01_06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TTR5R",
      "size": 22410088,
      "reboot_required": true,
      "description": "BOSS-S2 ROM version 2.5.13.4009",
      "revision_history": "Fixes:\n\n-- Addressed false M.2 failures reported due to thermal issues \n               \nEnhancements:\n-- Added new SDID 0x2261 on BOSS-S2 controller"
    },
    {
      "id": "2100af4e9173bdff79684c91aba38c704677dabc553c7215357fc544f34ae220",
      "name": "Dell OS Driver Pack",
      "version": "25.04.03",
      "release_id": "RY43K",
      "category": "Drivers for OS Deployment",
      "category_slug": "drivers-for-os-deployment",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-09-15T05:49:55Z",
      "released": "2025-05-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13060523M/3/Drivers-for-OS-Deployment_Application_RY43K_WN64_25.04.03_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RY43K",
      "size": 35156056,
      "reboot_required": false,
      "description": "OS Driver Pack for PowerEdge 15G servers. This Driver Pack contains applicable storage and embedded LOM drivers to support OS installation using the Dell Lifecycle Controller",
      "revision_history": "N/A"
    },
    {
      "id": "448ded191420b195668e21a896d8e278e90683ea41473b713cb91404b90354bf",
      "name": "Broadcom NetXtreme network device firmware (Dell), 23.8",
      "version": "23.81.6",
      "release_id": "6W3WV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-08T03:06:44Z",
      "released": "2026-09-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14991490M/2/Network_Firmware_6W3WV_WN64_23.81.6.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6W3WV",
      "size": 22772392,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for Broadcom NetXtreme devices.  This release should be used with the Broadcom 23.8 device drivers."
    },
    {
      "id": "4175d48092d0c8309e216153c7b743dbea59b1590da4dedc03c2970bca816070",
      "name": "MICRON 5100 max Pro RI/ Pro boot M.2 SATA \u0026apos;L013\u0026apos; FW for model number(s) MTFDDAV240TCB, MTFDDAV480TCB, MTFDDAV960TCB, MTFDDAV1T9TCB, MTFDDAK240TCB, MTFDDAK480TCB, MTFDDAK960TCB, MTFDDAK1T9TCB",
      "version": "L013",
      "release_id": "RTND5",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-04T14:23:56Z",
      "released": "2026-08-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14983889M/1/Serial-ATA_Firmware_RTND5_WN64_L013_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RTND5",
      "size": 26470688,
      "reboot_required": true,
      "description": "This release contains firmware version L013 for MICRON model number(s) MTFDDAV240TCB, MTFDDAV480TCB, MTFDDAV960TCB, MTFDDAV1T9TCB, MTFDDAK240TCB, MTFDDAK480TCB, MTFDDAK960TCB, MTFDDAK1T9TCB.  Capacity of 5100 max Pro boot 240GB, 480GB, 960GB, 1.92TB. Pro RI 240GB, 480GB, 960GB and 1.92TB",
      "revision_history": "Fixes:\n1. D0DL013 addresses this issue.  The updated behavior will be:\n2. LogEntryCnt = 65,535 Exit the workload log function directly; no workload log entry is recorded.\n3. LogEntryCnt = 0 to 65,534 Workload log recording continues as originally designed."
    },
    {
      "id": "40a5d823af38ca2ebe7cbf8287901fe09aafe6fca47e6048df8429e0f104815d",
      "name": "Microsoft Windows x64 management driver for BOSS",
      "version": "1.2.0.1052",
      "release_id": "8KKVC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-31T12:12:02Z",
      "released": "2021-07-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07524633M/9/SAS-RAID_Driver_8KKVC_WN64_1.2.0.1052_A02_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8KKVC",
      "size": 17014984,
      "reboot_required": false,
      "description": "Microsoft Windows x64 management driver for BOSS",
      "revision_history": "Fixes: None,\nEnhancements: YES , Signed Binaries\nConsole Management Driver for all Windows Operating systems\nSupport for Windows Azure HCI Stack \u0026 Windows 2022 enabled"
    },
    {
      "id": "1aa67fe97be9b69f74c41d082bf3193e5c0511a1cbaac86f436a4b56b04d5149",
      "name": "BOSS-S1 Adapter firmware",
      "version": "2.5.13.3024",
      "release_id": "3P39V",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-28T11:06:39Z",
      "released": "2020-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06189651M/8/SAS-RAID_Firmware_3P39V_WN64_2.5.13.3024_A07_07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3P39V",
      "size": 23542088,
      "reboot_required": true,
      "description": "BOSS-S1 Adapter ROM version 2.5.13.3024",
      "revision_history": "Fixes:YES\nFixed PPID Discrepancy for M.2 drives of BOSS controller in iDRAC Hardware inventory page\nFixed an issue to resolve the Offline Bundle installation of ESXi 6.x CLI via VUM\nFixed a behavior in firmware to handle when create \u0026 delete VD command execute in loop.\nEnhancements:YES\nNew unified BOSS Console/Management driver for all Windows operating systems."
    },
    {
      "id": "e030fecbf94eb9512ae1dfa4fb776046fd4612d06268cb14e6909c5d697489ae",
      "name": "BOSS-S1 Modular firmware",
      "version": "2.6.13.3025",
      "release_id": "F9F16",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-27T11:07:40Z",
      "released": "2023-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09214778M/11/SAS-RAID_Firmware_F9F16_WN64_2.6.13.3025_A08_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F9F16",
      "size": 23542872,
      "reboot_required": true,
      "description": "BOSS-S1 Modular ROM version 2.6.13.3025",
      "revision_history": "Fixes : HW Re-spin \nAddressed false M.2 failures reported due to thermal issues\n\nEnhancements : Added new SDID 0x2260 on BOSS-S1 controller"
    },
    {
      "id": "bd3794af46567901c2ff036721b34a42514f6f0f2aa3bbe159c848331f37d619",
      "name": "NVIDIA Mellanox Firmware Release 16.35.80.02 for NVIDIA Mellanox ConnectX-5 Ethernet Adapters",
      "version": "16.35.80.02",
      "release_id": "DWXP5",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-08-21T05:18:20Z",
      "released": "2026-03-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14930224M/1/Network_Firmware_DWXP5_WN64_16.35.80.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DWXP5",
      "size": 46059904,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Nvidia Mellanox firmware release 16.35.80.02 on NVIDIA Mellanox ConnectX-5 Ethernet adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "2cfb5d1f16ddc7672fb89251188bf188d61b25334440ba70289057a49c93cf2c",
      "name": "Intel NIC Family Version 25.0 Drivers for Windows 64-bit Operating Systems",
      "version": "25.0.0",
      "release_id": "J99NN",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-04T00:23:11Z",
      "released": "2026-08-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14855482M/1/Network_Driver_J99NN_WN64_25.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J99NN",
      "size": 53939904,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt."
    },
    {
      "id": "64c3b0521b620435ff6f16d6e050214f67b7fbe7f3a70d5205394e41833db3a9",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.8",
      "version": "23.81.0",
      "release_id": "RNT70",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:51:28Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843705M/1/Network_Driver_RNT70_WN64_23.81.0_238.1.170.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RNT70",
      "size": 14747512,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "e383c232a59d867730c67aff93fece1f8bb4e33d1f8f1d0795276821d80c6740",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.8 update.",
      "version": "38.11.70.00",
      "release_id": "X9DJG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:44:02Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843656M/2/Network_Driver_X9DJG_WN64_38.11.70.00_238.1.170.0_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9DJG",
      "size": 17265544,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "7a614f2dd02a71f7264337b85eb55d6adcb4d0302e69a8d71ab2c7eae29d15bf",
      "name": "PERC H755 RAID Controller firmware version 52.30.0-6753",
      "version": "52.30.0-6753",
      "release_id": "N6C86",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-06-02T16:27:30Z",
      "released": "2026-06-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14615957M/4/SAS-RAID_Firmware_N6C86_WN64_52.30.0-6753_A11_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N6C86",
      "size": 32673752,
      "reboot_required": true,
      "description": "PERC H755 RAID Controller firmware version 52.30.0-6753",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions, including Single Bit Errors (SBE) and Multi Bit Errors (MBE).\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown to power off the system, followed by a power on to enable the new memory settings.\nA warm reboot will NOT activate the updated settings.\nIf iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required."
    },
    {
      "id": "78c2385f78e01efa51a8798695530f7a9d445ab7b40872bfb2d691b7e9e3b663",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.5",
      "release_id": "KRHCN",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-05-06T15:41:31Z",
      "released": "2026-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14515537M/1/Express-Flash-PCIe-SSD_Firmware_KRHCN_WN64_2.0.5_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KRHCN",
      "size": 27415688,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release"
    },
    {
      "id": "60553b31a0c7840eea26725f7b5326f9b56066af9311d5db5722d384d7880959",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "version": "3.0.6",
      "release_id": "7H42K",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-05-06T15:25:06Z",
      "released": "2026-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14515495M/1/Express-Flash-PCIe-SSD_Firmware_7H42K_WN64_3.0.6_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7H42K",
      "size": 27628736,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release"
    },
    {
      "id": "c9b41b21cbbcb00bd5365d004fa23c5cfc5886c7562f50846076b5e00df72bcf",
      "name": "Intel NIC Family Version 25.0.0 Firmware for Intel I350 and X550 Adapters",
      "version": "25.0.4",
      "release_id": "HMDDR",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-02-12T15:08:34Z",
      "released": "2026-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14205749M/2/Network_Firmware_HMDDR_WN64_25.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HMDDR",
      "size": 23253664,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.X on Intel I350 and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.X on Intel I350 and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "f90cc54712c96fa90b3d686e1a364c9add6a13f9467ab55c5b33f3095b0ab102",
      "name": "Intel NIC Family Version 25.0.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "25.0.4",
      "release_id": "PJDHV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-02-12T14:50:50Z",
      "released": "2026-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14205977M/2/Network_Firmware_PJDHV_WN64_25.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PJDHV",
      "size": 46329512,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "See the fw_release_x710.txt file for more information."
    },
    {
      "id": "8e9c30fc9b9ba6c222b03354fbe3512accdaedd94a1db3099eafbe926f2f3bf7",
      "name": "Intel NIC Family Version 25.0.0 Firmware for Intel E810 Adapters and Intel E823 LOM",
      "version": "25.0.4",
      "release_id": "FCG2V",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-02-12T14:41:44Z",
      "released": "2026-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14206113M/1/Network_Firmware_FCG2V_WN64_25.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FCG2V",
      "size": 72664168,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.x on Intel E810 adapters and Intel E823 LOM. This release provides continued code optimization to improve performance.",
      "revision_history": "See fw_release_e810_e823.txt for more information."
    },
    {
      "id": "cca5695e4a8e61074fdc1de3a322725393df6e48f8498fa5f2dd6e2c301186f7",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "71KRG",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-12-16T18:48:47Z",
      "released": "2025-09-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13990425M/1/Express-Flash-PCIe-SSD_Firmware_71KRG_WN64_1.2.0_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=71KRG",
      "size": 29639544,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Improvements to drive internal logging.\n2. Improvements to SMART logging and notification.\n3. Resolved sideband firmware download issue.\n\nEnhancements:\n\n1. Additional support added for firmware update for Dell 17th generation servers.\n2. Additional support added for firmware update for Dell PERC 12 and 13 controllers."
    },
    {
      "id": "45702dc92959e5bb5ad182958bf5511ee357e045afd9ff6a07da3678ffbe525e",
      "name": "Mellanox ConnectX-6 LX Ethernet Adapter Firmware",
      "version": "26.40.1000",
      "release_id": "633VJ",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-12-03T13:31:34Z",
      "released": "2025-11-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13939058M/1/Network_Firmware_633VJ_WN64_26.40.1000_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=633VJ",
      "size": 40892520,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-6 LX Adapters"
    },
    {
      "id": "f5bfd9963a31ba63314fe7c5b7136b0192d0e64945355d999a0c5bb21ce10910",
      "name": "Mellanox ConnectX-6 DX Ethernet Adapter Firmware",
      "version": "22.40.1000",
      "release_id": "CNC6W",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-26T03:33:03Z",
      "released": "2025-11-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13911831M/1/Network_Firmware_CNC6W_WN64_22.40.1000_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CNC6W",
      "size": 41383744,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-6 DX Adapters"
    },
    {
      "id": "084c4c862eb04bca11886df3cc480d08a1b762a058189ccf46755ff6564037c4",
      "name": "Dell Express Flash NVMe P5520/P5620 PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "12W9R",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-10-31T17:04:04Z",
      "released": "2025-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13807766M/1/Express-Flash-PCIe-SSD_Firmware_12W9R_WN64_1.5.0_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=12W9R",
      "size": 27905664,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P5520/5620 PCIe SSD Firmware Release MR4"
    },
    {
      "id": "18db910ff4ed477c8296e6b844189a18134ef2fec5793433edea50ab24ff9ea6",
      "name": "Non-Expander Storage Backplane Firmware for Select PowerEdge Platforms",
      "version": "7.16",
      "release_id": "5DV1W",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-10-10T17:59:05Z",
      "released": "2025-10-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13712463M/6/Firmware_5DV1W_WN64_7.16_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5DV1W",
      "size": 22774896,
      "reboot_required": false,
      "description": "Passive SEP Backplane Firmware for 15th Generation PowerEdge 1U and select XE and XR Systems",
      "revision_history": "Firmware 7.16\n\nFixes:\n- None\n\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\n\nChange History:\n\nFirmware 7.10\nFixes:\n- Addressed a potential backplane issue where some slot descriptor values are not correctly initialized which could prevent the storage controller and/or hard drives from being displayed in the iDRAC Storage inventory.\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 6.97\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 3.72\nFixes:\n- Corrected issue with false drive detection in unpopulated slots\nEnhancements:\n- None\n\nFirmware 3.67\nFixes:\n- None\nEnhancements:\n- Added support for for new PowerEdge storage configurations.\n\nFirmware 3.57\nFixes:\n- Minor bug fixes\nEnhancements:\n- Added support for for new PowerEdge storage configurations.\n\nFirmware 3.56\nFixes:\n- Minor bug fixes\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 3.48\nFixes:\n- Minor bug fixes\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 3.43\nFixes:\n- Minor bug fixes\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 3.04\nFixes:\n- Minor bug fixes\nEnhancements:\n- Enables PCIe Gen4 speeds for NVMe devices.\n- Adds support for new PowerEdge storage configurations.\n\nFirmware 2.84\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 2.41\nFixes:\n- Fixed a condition where the backplane could hang during drive hot-plug.\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 2.30\n- Initial Release"
    },
    {
      "id": "b273e5333c982c058658bb02706513e6ad4c6638f023d2d189238adf7466ebe0",
      "name": "NVIDIA Mellanox Firmware Release 20.43.36.08 for NVIDIA Mellanox ConnectX-6 VPI Adapters on Dell 14G and 15G AMD-Based Servers",
      "version": "20.43.36.08",
      "release_id": "MY5RY",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-10-10T00:13:22Z",
      "released": "2025-09-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13711351M/2/Network_Firmware_MY5RY_WN64_20.43.36.08_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MY5RY",
      "size": 39919424,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Nvidia Mellanox firmware release 20.43.36.08 on NVIDIA Mellanox ConnectX-6 VPI adapters on Dell 14G and 15G AMD-based systems. This release provides continued code optimization to improve performance.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "bc20d7bbdd73425a126be1aa9a9baaf4273de370b22b151f7af3fa187cb42b4a",
      "name": "Dell Express Flash NVMe PCIe SSD CM6 Maintenance Firmware Release",
      "version": "2.2.2",
      "release_id": "GMM6V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-20T03:23:06Z",
      "released": "2024-07-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11805909M/3/Express-Flash-PCIe-SSD_Firmware_GMM6V_WN64_2.2.2_A08_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GMM6V",
      "size": 28521944,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM6 Firmware Maintenance Release"
    },
    {
      "id": "c4bf141c6378349d3febc74b35f5a3024900e88e5afeb3a1a67d0c554248998e",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.1 update.",
      "version": "23.11.16.21",
      "release_id": "8YWJY",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-20T03:19:10Z",
      "released": "2024-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12155596M/4/Network_Driver_8YWJY_WN64_23.11.16.21_231.1.162.1_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8YWJY",
      "size": 14278288,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- Stop 0x133 blue screen on Windows Azure Stack HCI.\n\nEnhancements:\n- none."
    },
    {
      "id": "b3756f56e76fb6fdf6d53d9bc0bb41fa37aaf9ec858ba959301334044cd538e7",
      "name": "DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR",
      "version": "DL7C",
      "release_id": "VJPKG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-08-19T07:07:49Z",
      "released": "2025-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12600340M/4/Serial-ATA_Firmware_VJPKG_WN64_DL7C_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJPKG",
      "size": 22988728,
      "reboot_required": false,
      "description": "This is a firmware release for DELLSLDM Youngsville-RR  DL7C firmware for Model number(s) SSDSC2KB240GZR, SSDSC2KB480GZR, SSDSC2KB960GZR, SSDSC2KB019TZR, SSDSC2KB038TZR, SSDSC2KB076TZR, SSDSCKKB240GZR, SSDSCKKB480GZR,SSDSC2KG480GZR, SSDSC2KG960GZR, SSDSC2KG019TZR, SSDSC2KG038TZR",
      "revision_history": "Issue: During a warm Reboot the YVRR drive may intermittently disappear when connected to the PERC H965i\nFix: DL7C FW now addresses this issue\nIssue: PLI capacitor charge flag not set leads drive to enter disable logical mode\nFix: DL7C FW now addresses this issue"
    },
    {
      "id": "6b8fe0e8d91ff1271a42ada59a153ff6182e02d9af7e3d6ab2ede54b99a9287d",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.0",
      "version": "23.00.0",
      "release_id": "GJ9N4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-14T05:26:36Z",
      "released": "2024-09-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11901569M/3/Network_Driver_GJ9N4_WN64_23.00.0_230.1.116.0_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GJ9N4",
      "size": 14389968,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- BCM5719 missing Jumbo MTU and LSO options in Advanced Properties.\n\nEnhancements:\n- Add support for Windows Server 2025."
    },
    {
      "id": "dc8129f8e809b3ef0059b5776f5811a8bf3f8bfb75c0c5a365a994b47bd55d25",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.0 update.",
      "version": "23.01.11.60",
      "release_id": "FPMGT",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-13T09:16:08Z",
      "released": "2024-09-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11901574M/3/Network_Driver_FPMGT_WN64_23.01.11.60_230.1.116.0_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FPMGT",
      "size": 14640336,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for Windows Server 2025."
    },
    {
      "id": "3d43b16d899574bcaaf624d69349e485c2b6de77f10e32ee06016cfe013710e8",
      "name": "This release contains firmware version HL56 for supplier model number(s) MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "version": "HL56",
      "release_id": "NF72T",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-06-24T17:56:25Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12607145M/2/Serial-ATA_Firmware_NF72T_WN64_HL56_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NF72T",
      "size": 25020384,
      "reboot_required": false,
      "description": "This release contains firmware version HL56 for supplier model number(s)MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "revision_history": "Fixes: \n\n- Disabled Send / Receive FPDMA for QTRIM commands\n- Disabled NCQ Non-Data commands\n- Addressed PLP Timeout / Error Mode by correcting LPage Handles hash algorithm\n- Improved Unmap policy during Sanitize\n- Altered Protective Reclaim (PR) operation to better manange hot-spot reads"
    },
    {
      "id": "ecea33696153990ad446eddf64bc3b31180d12bdb42af975eaf0ec0d89954e53",
      "name": "Samsung HK56 FW for PM897a SATA drive program for model number(s) MZ7L3480HELTAD3, MZ7L3960HELAAD3, MZ7L31T9HENAAD3, MZ7L33T8HENAAD3",
      "version": "HK56",
      "release_id": "KHC8M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:55:37Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12607553M/2/Serial-ATA_Firmware_KHC8M_WN64_HK56_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHC8M",
      "size": 25015744,
      "reboot_required": false,
      "description": "This release contains firmware version HL56 for supplier model number(s)MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "revision_history": "Fixes: \n\n- Disabled Send / Receive FPDMA for QTRIM commands\n- Disabled NCQ Non-Data commands\n- Addressed PLP Timeout / Error Mode by correcting LPage Handles hash algorithm\n- Improved Unmap policy during Sanitize\n- Altered Protective Reclaim (PR) operation to better manange hot-spot reads"
    },
    {
      "id": "3ba243687a1eef86fefe2f16237159b1933e93d3275f272b28076d00a05ae847",
      "name": "Samsung PM897 SATA SSDs for HH62 firmware for models MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "version": "HH62",
      "release_id": "Y4WVW",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:54:57Z",
      "released": "2025-01-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12519999M/3/Serial-ATA_Firmware_Y4WVW_WN64_HH62_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=Y4WVW",
      "size": 25286320,
      "reboot_required": false,
      "description": "This release contains firmware version Samsung HH62 for model number(s) MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "revision_history": "Fixes: \n- Enhanced Reclaim Policy and reduced COMRST to 1 sec. to address PDL issue\n- Enhanced PLP/SNOR logging, to improve debuggability"
    },
    {
      "id": "a98c02887bb372e7fadcc37e7683cc77cf178f75e811b60543320fbd00d0b70c",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.3.0",
      "release_id": "RPTG2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:09:38Z",
      "released": "2025-01-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12505166M/2/Express-Flash-PCIe-SSD_Firmware_RPTG2_WN64_1.3.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RPTG2",
      "size": 29108768,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \n\n1. Firmware will preserve the CSTS.CFS bit as long as the drive is in panic. \n2. Disable Latency Tolerance Reporting (LTR) in FW\n3. Implemented a fix to ensure that the drive does not miss the TS1 from the host which will allow the host to exit the L1 Entry state and prevent the link from being reset.\n4. FW now shows specific values per capacity in the Sanitize Status log page\n5. Resolved the issue of the drive internal bit remaining set after a reboot. This ensures that AERs will not be disabled.\n6. Improve APL handling in FW.\n7. Improve handling of invalid commands in FW to prevent asserts.\n8. Improve TRIM handling in FW\n9. Improve thermal shutdown behavior to avoid assert. \n10. Improve PERST handling to prevent assert in this situation \n11. Improved OOB command handling in FW especially during shutdown\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "63d569a7c0079911874d1a5946769ef611585688f97884cb2c6411d889e4aa77",
      "name": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "version": "2.0.2",
      "release_id": "FW43N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T10:58:02Z",
      "released": "2025-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12549106M/2/Express-Flash-PCIe-SSD_Firmware_FW43N_WN64_2.0.2_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FW43N",
      "size": 29842576,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n\n1. Fix the bug that write index of SMBus ring buffer was out of sync.\n2. For PCI Information such as PCI Vendor ID other than BDF, FW also keeps their value. So, fixed to respond the value directly from FW instead of getting them from HW.\n3. Reverse the rows and columns of the Printable Eye values in the EOM Lane Descriptor and reverse the MaxTB and MaxLR values in the EOM Header.\n4. With current CD8P FW, host should use AUSE=1 to run Block Erase in Sanitize command. If block erase failed, host can use Exit failure mode to release the failure status.\n5. FW is fixed to enable the SRAM 1-bit error correction feature during the initialization of the SoC\n6. Modify the drive FW to re-allocate the DRAM range for VDM to eliminate the arbiter from being locked when three different DRAM Wr access (one is for VDM) come in simultaneously.\n\nEnhancements:  \nN/A"
    },
    {
      "id": "72edf6a3bd3e7561ff46a85ae83b2753b40bcd7368e4884558a1de18497c0740",
      "name": "Dell Express Flash NVMe PCIe SSD CD8 U.2 OPAL Firmware Maintenance Release",
      "version": "1.0.1",
      "release_id": "11TRD",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T10:21:01Z",
      "released": "2025-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12428385M/2/Express-Flash-PCIe-SSD_Firmware_11TRD_WN64_1.0.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=11TRD",
      "size": 29787784,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8 U.2 OPAL Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. For PCI Information such as PCI Vendor ID other than BDF, FW also keeps their value. So, fixed to respond the value directly from FW instead of getting them from HW.\n2. Instead of clearing the Abort flag at the beginning of the response data retransfer processing task, modify it to clear the Abort flag when data transfer after retransfer becomes possible.\n3. Fix the bug that write index of SMBus ring buffer was out of sync.\n4. Max payload size is immediately reflected in the internal register when the value is changed.\n5. Wait for transition from Recovery when VDM packet forwarding is completed.\n6. Fixed to resume Write process after NAND Timeout recovery process.\n7. Set OACS bit10 to 1 to remove support of Lockdown on the in-band interface.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "ec564cb8c9f2124425b5f58e5f7dfcc480633219125075b2d358a0a31c167266",
      "name": "Dell 64 Bit uEFI Diagnostics, version 4303",
      "version": "4303A28",
      "release_id": "3GX21",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2025-06-19T06:56:52Z",
      "released": "2024-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12170967M/2/Diagnostics_Application_3GX21_WN64_4303A28_4303.28_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3GX21",
      "size": 9386600,
      "reboot_required": false,
      "description": "Dell Diagnostics are designed to verify proper operation of the hardware in your system outside of a high-level operating system environment. The files in this group can be used to update these diagnostics on a system with a Lifecycle Controller.",
      "revision_history": "This release contains minor bug fixes and enhancements."
    },
    {
      "id": "fcb86d9b5e1472e571103417d19ca03e700321d4d92cd23bd7951fa87f4cae08",
      "name": "Samsung PM883a RI SSDR, FW HG60 for model number(s) MZ7LH240HBHQAD3, MZ7LH480HBHQAD3, MZ7LH960HBJRAD3, MZ7LH1T9HALTAD3, MZ7LH3T8HALTAD3, and MZ7LH7T6HALAAD3",
      "version": "HG60",
      "release_id": "107CV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-12T11:17:47Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12756666M/3/Serial-ATA_Firmware_107CV_WN64_HG60_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=107CV",
      "size": 25011520,
      "reboot_required": false,
      "description": "This firmware update includes command updates, improvements in PLP timeout handling, and optimized controller logic to improve slow writes. version HG60 firmware for Samsung PM883a SATA SSDs models MZ7LH240HBHQAD3, MZ7LH480HBHQAD3, MZ7LH960HBJRAD3, MZ7LH1T9HALTAD3, MZ7LH3T8HALTAD3, and MZ7LH7T6HALAAD3",
      "revision_history": "- PLP Timeout Fix\n- Improved COMRST response (\u003c1 sec.)\n- Enhanced Reclaim policy to improve hot spot read reclam"
    },
    {
      "id": "0ec4a72763c6f617356a0e2ee5e7e3aad191109ec75324d8f0202fff4986bbaf",
      "name": "Mellanox Windows 64-bit Server OS drivers for Mellanox ConnectX-4 Lx, ConnectX-5, ConnectX-6 and ConnectX-7 Ethernet adapters",
      "version": "25.1",
      "release_id": "3G71F",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-04-23T17:03:08Z",
      "released": "2025-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13036121M/1/Network_Driver_3G71F_WN64_25.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3G71F",
      "size": 213767824,
      "reboot_required": false,
      "description": "This package provides the Windows 64-bit drivers for Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, and ConnectX-7 Ethernet Adapters and is supported on Dell EMC PowerEdge servers with the following operating systems: Windows Server 2019 and Windows Server 2022"
    },
    {
      "id": "736e89923bb3c28df28dc52a33909657ef3c7f17816fa6be7cd3ade0082728b9",
      "name": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "version": "C40E",
      "release_id": "57MM2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:28:10Z",
      "released": "2024-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374876M/2/SAS-Drive_Firmware_57MM2_WN64_C40E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=57MM2",
      "size": 24391360,
      "reboot_required": false,
      "description": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "revision_history": "Fixes: \n\n- Fix1: FW is fixed to execute the flush process and Flash Memory parameter modification process exclusively.\n- Fix2: Fixed that the host I/O proceed by the skip of GC if the validity determination process of user data takes time.\n- Fix3: Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "2d586d18bf6bfd668a4b76e782765a56bb78bffe1a219c60613e9b1ae474dbde",
      "name": "Model numbers are KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8, KPM7XRUG960G, KPM7XVUG800G, KPM7XMUG400G, KPM7XMUG800G, KPM7XMUG1T60",
      "version": "C10E",
      "release_id": "T21WT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:11:55Z",
      "released": "2024-06-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374981M/2/SAS-Drive_Firmware_T21WT_WN64_C10E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T21WT",
      "size": 24314272,
      "reboot_required": false,
      "description": "This release contains firmware version C10E for Kioxia PM7 24Gbps SAS 2.5 (10WPD, 1WPD, 3WPD).\nModel numbers are KPM7XMUG400G, KPM7XMUG800G, and KPM7XMUG1T60,\nKPM7XVUG800G, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8,KPM7XRUG960G, KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3.",
      "revision_history": "Fix:\n\n-  Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "0776b5d687d3fbafca1eb2f20fa128d1b4ec7423dcc2fefe3e9f3387ab95092f",
      "name": "Kioxia BA48 FW for PM6 drives for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "version": "BA48",
      "release_id": "NGPR2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T05:55:37Z",
      "released": "2022-09-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08764563M/4/SAS-Drive_Firmware_NGPR2_WN64_BA48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NGPR2",
      "size": 24171504,
      "reboot_required": false,
      "description": "Kioxia PM6 BA48 FW for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "revision_history": "Fixes:\nInitial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "ee1dd07dfa56c50a22f52b957c6eea53779375c00ea310b32677d2cc45dccbfd",
      "name": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68",
      "version": "BD48",
      "release_id": "6DH0W",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-07T09:55:22Z",
      "released": "2023-10-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10704397M/4/SAS-Drive_Firmware_6DH0W_WN64_BD48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6DH0W",
      "size": 24247952,
      "reboot_required": false,
      "description": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68.",
      "revision_history": "Fixes :\n- Initial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "90185f8e0eb9a36b0268f12c76033b8595571088acd45cdc75763cf19f7ffb4b",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.2",
      "version": "23.21.5",
      "release_id": "YWMRX",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-14T01:06:32Z",
      "released": "2025-01-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12577197M/2/Network_Driver_YWMRX_WN64_23.21.5_232.1.133.2_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YWMRX",
      "size": 13975856,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Support for new Dell server models."
    },
    {
      "id": "8805f93f162a5e9a7282553f3a2eb98d8cfd822f43e29e41219e7f999c02fac5",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.2 update.",
      "version": "23.21.13.32",
      "release_id": "G535X",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-14T01:03:16Z",
      "released": "2025-01-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12577171M/2/Network_Driver_G535X_WN64_23.21.13.32_232.1.133.2_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G535X",
      "size": 14210264,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver."
    },
    {
      "id": "ab13ae4fdb4fa0345532494866bbbc497d0ca9dccb6790c83aa34bdfdc8dc834",
      "name": "Samsung PM893 SATA SSDs for HJ62 firmware for models MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3",
      "version": "HJ62",
      "release_id": "537XV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-12-24T13:41:29Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12519998M/1/Serial-ATA_Firmware_537XV_WN64_HJ62_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=537XV",
      "size": 13233416,
      "reboot_required": false,
      "description": "This release contains firmware version Samsung HJ62 for model number(s) MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3.",
      "revision_history": "Fixes: \n\n- Enhanced Reclaim Policy and reduced COMRST to 1 sec. to address PDL issue.\n- Enhanced PLP/SNOR logging, to improve debuggability."
    },
    {
      "id": "9919a72526e3192f77c158c625e5ec4efa06638905b3c239de5820e669db369e",
      "name": "BOSS Console Management driver for WS2022-2025",
      "version": "1.2.0.1055",
      "release_id": "7004G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-12-18T11:18:14Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11846807M/2/SAS-RAID_Driver_7004G_WN64_1.2.0.1055_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7004G",
      "size": 12936864,
      "reboot_required": false,
      "description": "BOSS Console Management driver for WS2022-2025",
      "revision_history": "Fixes: None,\nEnhancements: Console Management Driver enablement for MS Windows 2025."
    },
    {
      "id": "5fbb2cc5367bda7400ad0c2fb39609d290f04eb662c6bef1a480239f4b0c179c",
      "name": "Windows Server 2022 64bit driver for PERC S150 Controller",
      "version": "6.9.0.0001",
      "release_id": "YWCD7",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-09-17T13:13:28Z",
      "released": "2024-09-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12106750M/1/SAS-RAID_Driver_YWCD7_WN64_6.9.0.0001_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YWCD7",
      "size": 6634760,
      "reboot_required": true,
      "description": "Windows Server 2022 64bit driver for PERC S150 Controller"
    },
    {
      "id": "2e142fa2b3bba65e6701761803eb6b88963468bee9960a715304452f1a20de58",
      "name": "Intel NIC Family Version 23.0.0 Firmware for Intel I350 and X550 Adapters",
      "version": "23.0.8",
      "release_id": "WVM0R",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-08T02:04:05Z",
      "released": "2024-07-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890380M/3/Network_Firmware_WVM0R_WN64_23.0.8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WVM0R",
      "size": 13964792,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 23.0.X on Intel I350, I354 and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "Fixes\n=====\n   - Fixed problem where updating I350 NICs would not preserve the Virtualization Mode and would reset \n     the Virtualization Mode to the factory default of \"None\". {266366}\n   - Fixed an issue where Intel i350-based NICs would display invalid boot options in Boot Manager in the \n     legacy boot mode. {277961}\n     \nKnown Issues\n============\n   - Devices based on the Intel(R) Ethernet I350 controller do not support the LLDP Discovery feature\n     with Dell iDRAC.\n   - Received packets with incorrect length can generate alarms in VMware ESXi 7.0U2 and later.\n     These alarms can be ignored. Please reference this VMware KB article for more details: \n     https://kb.vmware.com/s/article/83627. {229496, 232005}"
    },
    {
      "id": "a3327e1940b3fe3b81e47fa9d3bb7aeffd6956b5f4ee06f4a9f14c97f3c83a19",
      "name": "Samsung PM1653 drives for DSG9 FW for model numbers MZILG960HCHQAD3, MZILG1T9HCJRAD3, MZILG3T8HCLSAD3, MZILG7T6HBLAAD3 and MZILG15THBLAAD3",
      "version": "DSG9",
      "release_id": "3MV58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T17:20:50Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11939710M/1/SAS-Drive_Firmware_3MV58_WN64_DSG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3MV58",
      "size": 13264392,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count acuracy and drive temperature reporting during format operations. Firmware version DSG9 for Samsung PM1653 drives. Vendor model numbers MZILG960HCHQ-0AD3, MZILG1T9HCJR-0AD3, MZILG3T8HCLS-0AD3, MZILG7T6HBLA-0AD3, and MZILG15THBLA-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "e15c231399536e80009d372366b4e72a4c66dedf951ad1fa78d1309ab3e37961",
      "name": "Samsung PM1655 drives for FW DWG9 for model numbers MZILG800HCHQAD3, MZILG1T6HCJRAD3 and MZILG3T2HCLSAD3",
      "version": "DWG9",
      "release_id": "7MTXM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T08:00:58Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11937657M/1/SAS-Drive_Firmware_7MTXM_WN64_DWG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7MTXM",
      "size": 13261200,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count accuracy and drive temperature reporting during format operations. Firmware version DWG9 for Samsung PM1655 drives. Vendor model numbers MZILG800HCHQ-0AD3, MZILG1T6HCJR-0AD3, and MZILG3T2HCLS-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "6dffa0fa05d98ecf5dd6f683737e3ab3d4e113f263fe4ec62004af5ecf3268e8",
      "name": "Intel NIC Family Version 23.0.0 Drivers for Windows 64-bit Operating Systems",
      "version": "23.0.0",
      "release_id": "6JHVK",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-07-19T15:27:45Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890492M/1/Network_Driver_6JHVK_WN64_23.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6JHVK",
      "size": 42776640,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "See readme.txt for more info."
    },
    {
      "id": "e304b4a3afc9985ef42898953bbb4c4c2209d80b9c683042b9eca3daf720a4c2",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "version": "3.1.3",
      "release_id": "JTTYW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T17:47:50Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674733M/1/Express-Flash-PCIe-SSD_Firmware_JTTYW_WN64_3.1.3_A06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTTYW",
      "size": 19213864,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "2d691ed72b31c474544f0a9a0818d69f0e4ab820992ea73115f41143fafef850",
      "name": "WD BCQ firmware G138  for model numbers WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200,WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200,WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200",
      "version": "G138",
      "release_id": "8W5WF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T07:34:09Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11655805M/1/SAS-Drive_Firmware_8W5WF_WN64_G138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8W5WF",
      "size": 12585960,
      "reboot_required": false,
      "description": "This release contains firmware version G138 for WD BCQ drives. Vendor model numbers WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200, WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200, WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries."
    },
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "333f510745d6bedcbadf00dfa27e5b7532c32ae94fea09bd9ec4a93617b1329f",
      "name": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s)  KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960",
      "version": "CA0C",
      "release_id": "1YD58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T15:53:43Z",
      "released": "2023-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10810459M/2/SAS-Drive_Firmware_1YD58_WN64_CA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1YD58",
      "size": 12708760,
      "reboot_required": false,
      "description": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s) KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960G.",
      "revision_history": "Fixes: \nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed in a different area, the drive may encounter the below failure mode. Once a drive falls into this failure mode, it cannot be recovered by power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. Data buffer is used for data transfer during Wear-Leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow.                                                                                                             Write Cache Issue: An issue that may cause firmware downloads to fail in the event of a capacitor failure. This failure is triggered by firmware download in the Write Cache Off state, and even if it occurs, it does not lead to drive failure and can be recovered by a reset or Power cycle.\nCause: When FW Update is executed in the Write Cache Off state and then restarted, capacitor discharge control is activated. In this case, unintended PLP occurs because capacitor discharge was controlled in the order of capacitor discharge and then PLP interrupt mask.\nFix: When capacitor discharge control is executed after FW Update in the Write Cache Off state and the system is restarted, the PLP interrupt mask is changed to control in the order of PLP interrupt mask and then capacitor discharge."
    },
    {
      "id": "8b123fe887879d8ad789dc986b35da9f2ec22affe26654a6bb6e8b20640f3cc6",
      "name": "Windows Server 2019 64bit driver for PERC S150 Controller",
      "version": "6.7.0.0003",
      "release_id": "XVCP2",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T16:00:59Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422723M/1/SAS-RAID_Driver_XVCP2_WN64_6.7.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XVCP2",
      "size": 6625104,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S150 Controller"
    },
    {
      "id": "11650d81b07b4ae4af9c7f55fe1767678d5db6f81209a32e256b0e098f2c701f",
      "name": "Dell EC NVMe SED 7450 RI M.2 80, MTFDKBA480TFR, MTFDKBA960TFR",
      "version": "2.1.0",
      "release_id": "YYYRJ",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-12T11:22:12Z",
      "released": "2024-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11363365M/1/Express-Flash-PCIe-SSD_Firmware_YYYRJ_WN64_2.1.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YYYRJ",
      "size": 8050312,
      "reboot_required": false,
      "description": "Dell EC NVMe SED 7450 RI M.2 80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes: \n\n- Firmware release includes bug fixes and enhancements added since the most recent prior firmware release 2.0.0."
    },
    {
      "id": "34c7cdbe33ff6937951237e4688c782c36ce0c1a9a134c21f78be30e094dd3e1",
      "name": "Dell Express Flash NVMe P5500/P5600 PCIe SSD Firmware Release",
      "version": "1.2.4",
      "release_id": "CGXH7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-03-07T15:53:46Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09999738M/2/Express-Flash-PCIe-SSD_Firmware_CGXH7_WN64_1.2.4_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CGXH7",
      "size": 17251184,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P5500/5600 PCIe SSD Firmware Release",
      "revision_history": "N/A"
    },
    {
      "id": "0e605d9211bcd8a02a879473d78eea4e314ae0715828727db3f5114b6575d264",
      "name": "PERC H740P/H840/H745 RAID Controller Firmware 51.16.0-4076",
      "version": "51.16.0-4076",
      "release_id": "F3J22",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-21T23:49:16Z",
      "released": "2021-07-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07551659M/2/SAS-RAID_Firmware_F3J22_WN64_51.16.0-4076_A16_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F3J22",
      "size": 26112328,
      "reboot_required": true,
      "description": "This release updates the firmware residing on PERC H740P, H840, and H745 controllers to package 51.16.0-4076",
      "revision_history": "Fixes: \n\n    -Fixed issue where controller would fault on boot in systems with multiple backplanes.\n    -Fixed issue where Medium Errors found on drives were not reported during rebuilds and copybacks.\n    -Fixed issue where controller would fault during a firmware downgrade.\n    -Fixed issue where Bad PHY events were incorrectly reported.\n    -Fixed issue where SATA Drives where controller would take too long to timeout a link recovery on an unresponsive drive."
    },
    {
      "id": "e449e713f727883989cd9404c9090cbd32d718e3c3342ca2682a7da9805c852b",
      "name": "Windows Server 2022 Driver 7.721.03.00 for PERC Controllers",
      "version": "7.721.03.0",
      "release_id": "95F5G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-02-21T15:44:28Z",
      "released": "2022-11-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09248656M/2/SAS-RAID_Driver_95F5G_WN64_7.721.03.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=95F5G",
      "size": 6062712,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver to 7.721.03.0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers.",
      "revision_history": "Added support for new PERC cards."
    },
    {
      "id": "1049cd9c99f385c9b304d694a8f655162a5c9387b1b356b2b9f1d098e61e0049",
      "name": "Windows Server 2019 Driver 7.721.03.0 for PERC Controllers",
      "version": "7.721.03.00",
      "release_id": "RYNG9",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-02-21T15:41:42Z",
      "released": "2022-11-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09248661M/2/SAS-RAID_Driver_RYNG9_WN64_7.721.03.00_A08_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RYNG9",
      "size": 6062848,
      "reboot_required": true,
      "description": "This release updates Windows 2019 Server driver to 7.721.03.0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers.",
      "revision_history": "Added support for new PERC cards."
    },
    {
      "id": "8b7171c9e267a84502b4dd3b631bc09cc0e0ab25b12cc110d8273af3b0f84615",
      "name": "Seagate 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "version": "4S0C",
      "release_id": "G04C8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-12T12:12:27Z",
      "released": "2022-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08459420M/2/SAS-Drive_Firmware_G04C8_WN64_4S0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G04C8",
      "size": 12625072,
      "reboot_required": false,
      "description": "This release contains Seagate firmware version 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "revision_history": "Fixes:\n-Fix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\n-Fix an issue that can return corrupt data after a power cycle in a corner case.\n-Fix an issue that can return the sense code 09/80/00 to a WRITE command.\n-Fix issues that can cause command timeout.\n-Fix issues that can cause drive assert.\n-Fix issues that can cause drive hang condition.\n\nEnhancements:\n-Improve protocol spec compliance.\n-Improve throughput performance for specific workloads.\n-Improve error logging/sense data reporting.\n-\nFix an issue that can cause drive-not-ready."
    },
    {
      "id": "dc4d9b31b476ffc086c28441a7060b994ff12bd8c7791266534a46aca19bec06",
      "name": "Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "version": "B02A",
      "release_id": "CPP97",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-12T04:37:43Z",
      "released": "2024-02-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11252185M/1/SAS-Drive_Firmware_CPP97_WN64_B02A_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CPP97",
      "size": 12644544,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "revision_history": "Fixes: \n\nFix1:  \n- A) When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  B) FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.                                                                                                                                                                              \nFix 2:\n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\nFix 3:\n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "adcdd14657ff15c5609da1a3bb478ca3f37b2bf3a1c019cba77db446f7b8f00b",
      "name": "Toshiba DBC4 for model number(s) KHK6YRM8240G, KHK6YRM8480G, KHK6YRSE480G, KHK6YRSE960G, KHK6YRSE1T92, KHK6YRSE3T84, KHK6YRSE7T68, KHK6YVSE480G, KHK6YVSE960G, KHK6YVSE1T92, KHK6YVSE3T84.",
      "version": "DBC4",
      "release_id": "W0YR1",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-02T06:44:59Z",
      "released": "2020-06-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06255401M/3/Serial-ATA_Firmware_W0YR1_WN64_DBC4_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=W0YR1",
      "size": 12622472,
      "reboot_required": false,
      "description": "This release contains firmware version DBC4 for Toshiba drives. Vendor model numbers KHK6YRM8240G, KHK6YRM8480G, KHK6YRSE480G, KHK6YRSE960G, KHK6YRSE1T92, KHK6YRSE3T84, KHK6YRSE7T68, KHK6YVSE480G, KHK6YVSE960G, KHK6YVSE1T92, KHK6YVSE3T84.",
      "revision_history": "Fixes:\n- Fixed error found during Write Uncorrectable testing that reported 07/27/00 instead of 03/11/00.\nEnhancements:\n- Added Pin 11 OOB Temperature reporting capability per ENG0015386 A04.\n- Performance improvements on Random Read and Write."
    },
    {
      "id": "d31a2b80867c52171a4c1e341a06b8297f7e871256099e506254c6a5c135d640",
      "name": "Dell PowerEdge Express Flash Ent NVMe v2 FIPS AGN Maintenance Firmware Release",
      "version": "3.5.0",
      "release_id": "2VG67",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:37:22Z",
      "released": "2023-11-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10824098M/2/Express-Flash-PCIe-SSD_Firmware_2VG67_WN64_3.5.0_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2VG67",
      "size": 21774520,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe v2 FIPS AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. NVMe-MI improvements.\n2. Persistent Event Log improvements.\n3. Fixed inssue with firmware update over NVMe-MI\n4. Drive becomes unresponsive after a reboot when TCG commands are outstanding.\n5. Corrected reported shutdown timeout values for 3.84TB, 6.4TB and 7.68TB capacity drives.\n\n\nEnhancements:\n\n1. Media access over sideband improvements.\n2. Enable Relaxed Ordering."
    },
    {
      "id": "d3068e476ab86d35d740df46573b012a443c549c62d3faca73aff63257f9e5fa",
      "name": "Dell PowerEdge Express Flash Ent NVMe v2 AGN Maintenance Firmware Release",
      "version": "2.5.0",
      "release_id": "5V3P7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:37:00Z",
      "released": "2023-11-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10823865M/2/Express-Flash-PCIe-SSD_Firmware_5V3P7_WN64_2.5.0_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5V3P7",
      "size": 21761944,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe v2 AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. NVMe-MI improvements.\n2. Persistent Event Log improvements.\n3. Fixed inssue with firmware update over NVMe-MI\n4. Drive becomes unresponsive after a reboot when TCG commands are outstanding.\n5. Corrected reported shutdown timeout values for 3.84TB, 6.4TB and 7.68TB capacity drives.\n\n\nEnhancements:\n\n1. Media access over sideband improvements.\n2. Enable Relaxed Ordering."
    },
    {
      "id": "851a48e9ba600ab67df61a16c04e18dcb1a8585e199a47ef484169481a12d1c2",
      "name": "Dell PowerEdge Express Flash Ent NVMe PE8010 SED Maintenance Firmware Release",
      "version": "1.3.0",
      "release_id": "C2C5M",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-01T15:27:03Z",
      "released": "2023-12-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10917317M/2/Express-Flash-PCIe-SSD_Firmware_C2C5M_WN64_1.3.0_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C2C5M",
      "size": 20144680,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash Ent NVMe PE8010 SED Firmware Release",
      "revision_history": "N/A"
    },
    {
      "id": "fcedf881f952e18cb7886f5bae15f0f5b345a33ba459c4e4e6004394bc50777b",
      "name": "Dell PowerEdge Express Flash Ent NVMe PE8010 Firmware Release",
      "version": "1.3.0",
      "release_id": "T1XKD",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T15:24:28Z",
      "released": "2023-08-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10443052M/3/Express-Flash-PCIe-SSD_Firmware_T1XKD_WN64_1.3.0_A04_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T1XKD",
      "size": 19878392,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash Ent NVMe PE8010 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected LED behavior to adhere to LED specifications\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "480d4e9ce14a83d2047d570eaf2ae2092e247347f514a1ca3e9da63fa1704440",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 22.7 update.",
      "version": "22.71.11.10",
      "release_id": "1TT78",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2024-01-31T23:20:53Z",
      "released": "2023-09-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10551555M/2/Network_Driver_1TT78_WN64_22.71.11.10_227.1.111.0_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1TT78",
      "size": 5933280,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.",
      "revision_history": "Fixes:\n- None.\n\nEnhancements:\n- Support for additional PowerEdge server models."
    },
    {
      "id": "c0c35ec567586d3e598e838a175f119121b72445109dbe8bf5b5795acfdf074a",
      "name": "Intel DL6R  for model number(s) SSDSCKKB240G8R, SSDSCKKB480G8R, SSDSCKKB960G8R.",
      "version": "DL6R",
      "release_id": "Y1P10",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T09:29:44Z",
      "released": "2020-09-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06303847M/2/Serial-ATA_Firmware_Y1P10_WN64_DL6R_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=Y1P10",
      "size": 12056704,
      "reboot_required": false,
      "description": "This release contains firmware version DL6R for Intel drives. Vendor model numbers  SSDSCKKB240G8R, SSDSCKKB480G8R, SSDSCKKB960G8R.",
      "revision_history": "Fixes:\n-SMART attribute shift solution\n-MRR settings to mitigate BJ004 issue\n-Fixes an issue where drive stops responding after soft-reboot following windows install\n\nEnhancements:\nN/A"
    },
    {
      "id": "eeb214c6eeee69a5f0df9a8a636c9e2cb91affb59cdc9a3d676d62028dad541d",
      "name": "Micron K803 for 5400 SATA model number(s) MTFDDAK7T6TGA",
      "version": "K803",
      "release_id": "333Y2",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-30T06:44:45Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606516M/2/Serial-ATA_Firmware_333Y2_WN64_K803_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=333Y2",
      "size": 12359152,
      "reboot_required": false,
      "description": "This release contains firmware version K803 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK7T6TGA",
      "revision_history": "Fixes:\n- Fixes to address performance."
    },
    {
      "id": "6c992026ccb1034e5d76c43933dc44c2595da3c48f49b380535843c14de95847",
      "name": "Micron K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "version": "K003",
      "release_id": "RJ0WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T14:41:30Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606437M/2/Serial-ATA_Firmware_RJ0WY_WN64_K003_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJ0WY",
      "size": 12627936,
      "reboot_required": false,
      "description": "This release contains firmware version K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "revision_history": "Fixes:\n\n-Fixes to address performance."
    },
    {
      "id": "7f5691c4430c7327b0a80ce3ef83995daadc50336c7a6a3a67edf9b560b1db34",
      "name": "Micron K403 for 5400 SATA model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB",
      "version": "K403",
      "release_id": "JTW3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T06:58:14Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606566M/2/Serial-ATA_Firmware_JTW3W_WN64_K403_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTW3W",
      "size": 12364032,
      "reboot_required": false,
      "description": "This release contains firmware version K403 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB.",
      "revision_history": "Fixes:\n\n- Fixes to address performance."
    },
    {
      "id": "0f2aad04e3d715fe60af5cb8dca609f6a76e3d07ca5f0ab96be68d1f12b515a0",
      "name": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "version": "B326",
      "release_id": "7FV43",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T11:30:04Z",
      "released": "2024-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11166204M/1/SAS-Drive_Firmware_7FV43_WN64_B326_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7FV43",
      "size": 12699824,
      "reboot_required": false,
      "description": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "revision_history": "Fixes: \n\nFix1:  \n- When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  Fixed FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.\n                                                                                                                                                                                   \nFix 2: \n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\n\nFix 3: \n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "121c2c65e1e9a03b00d25ba579c34f484234d576609fe0ed7e6c5860d47a0e0b",
      "name": "Samsung PM1643a drives for FW DSA4 for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "version": "DSA4",
      "release_id": "D7RNT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:05:17Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08612628M/2/SAS-Drive_Firmware_D7RNT_WN64_DSA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D7RNT",
      "size": 11328112,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1643a drives for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "f9290eb3b74efc450be944a10ae52b87ef4989382da72c3cd6b1a85e58859631",
      "name": "Seagate 3D03  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "version": "3D03",
      "release_id": "NKGWD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:03:59Z",
      "released": "2022-12-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09072701M/2/SAS-Drive_Firmware_NKGWD_WN64_3D03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKGWD",
      "size": 11993080,
      "reboot_required": false,
      "description": "This release contains firmware version 3D03 Seagate  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "revision_history": "Fixes:\nFix the drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can make the drive return 0B/44 to all commands until power cycled.\nFix issues that can cause drive assert.\nFix issues that can cause command timeout.\nFix issues that can cause drive-not-ready, including the case that can happen after power-cycle.\nFix issues that can cause drive hang condition.\nEnhancements:\nImprove error logging/sense data reporting."
    },
    {
      "id": "bb82cbf99973004ad4fa46b9d064ac1b23ea7e421990eef9b1994703259e53e1",
      "name": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095",
      "version": "CPE9",
      "release_id": "RRWVT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:56:16Z",
      "released": "2023-09-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10235085M/2/SAS-Drive_Firmware_RRWVT_WN64_CPE9_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RRWVT",
      "size": 12063856,
      "reboot_required": false,
      "description": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095,XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n- Fix drive detection issue.\n\nEnhancements:\n- Enable new DPN for 7.68TB capacity."
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "1422bba58673005e0d8a1f7d9ee1c898c81706f760e54c181b8a463dce6c5e22",
      "name": "Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "version": "BJ07",
      "release_id": "5WMK8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:21:19Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933394M/1/SAS-Drive_Firmware_5WMK8_WN64_BJ07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5WMK8",
      "size": 12038824,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "d8437b996ac697e05d66eea0c991e755d0142e2a4dbf3d2ad3bd95a4feb929d3",
      "name": "Intel NIC Family Version 22.0.0 Drivers for Windows Server 2019 and 2022 Operating Systems",
      "version": "22.0.0",
      "release_id": "X9PPT",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-13T18:44:32Z",
      "released": "2023-03-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09683951M/2/Network_Driver_X9PPT_WN64_22.0.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9PPT",
      "size": 44210816,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "Fixes\n=====\n- Resolved an issue where ETrackID, NVM Version, and FW Version field information was missing\n  in ProSet for X710, XL710, and XXV710 adapters. {242553}\n- Resolved an issue where on Windows Server OSs with Intel(R) Ethernet 25G 2P E810-XXV-k Mezz\n  adapters, hardware diagnostic tests using PROSet ACU would cause errors. {240055}\n\nEnhancements\n=====\n- Introduces performance counters manifest file for Intel (R) E810 devices, which can be imported into the \n  Microsoft Windows utility PerfMon. {D3752}"
    },
    {
      "id": "3e6433d387935a61626c4c49d78e992bbd48dcbd023e5e824374f6c97ced803b",
      "name": "PERC H740P/ H745 RAID Controller Firmware 51.16.0-5150",
      "version": "51.16.0-5150",
      "release_id": "96M5G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-09-29T13:41:58Z",
      "released": "2023-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10676343M/1/SAS-RAID_Firmware_96M5G_WN64_51.16.0-5150_A17.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=96M5G",
      "size": 21963976,
      "reboot_required": true,
      "description": "This release updates the firmware residing on PERC H740P, H840, and H745 controllers to package 51.16.0-5150",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions.\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown of the system to enable the new memory settings. A warm reboot will NOT activate the updated settings. If iDrac/LC is used to perform the update, a graceful shutdown after the update is still required.\n\nFirmware downgrade below 50.3.0-1022 is not supported without assistance from Dell due to the potential of data loss if steps are not performed correctly.\n-Call Dell technical support for guidance if this is required.\n\nFirmware downgrade from version 50.5.0-1750 or greater to a lower version while in Enhanced -HBA mode is not supported.\nFirmware downgrade from version 50.5.1-2633 or greater to a lower version while in OpenManage Secure Enterprise Key Manager mode is not supported.\n-H745 PERC controllers only support firmware version 50.9.2-2938 or greater"
    },
    {
      "id": "f00b0fb442568fef33a6e6b6f803cb2d327c1864b57c2f40c77208c11a0cff75",
      "name": "Intel NIC Family Version 22.5.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "22.5.7",
      "release_id": "1R0W0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T21:01:32Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646142M/1/Network_Firmware_1R0W0_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1R0W0",
      "size": 36581360,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "fe3df57f88a24821dcfe6da938dea1cb5969fd93d89df900376eb41cf1b3ac98",
      "name": "Intel NIC Family Version 22.5.0 Firmware for I350, I354, and X550 Adapters",
      "version": "22.5.7",
      "release_id": "TNXW1",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T20:37:20Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646092M/2/Network_Firmware_TNXW1_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TNXW1",
      "size": 16735312,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "7f3c1816a8abb0d5de05c5772def174d0e1ae5f6c9c2ad5523fd664903346ed8",
      "name": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "version": "CSJA",
      "release_id": "J12RT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-06-30T05:01:47Z",
      "released": "2023-06-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10268173M/1/SAS-Drive_Firmware_J12RT_WN64_CSJA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J12RT",
      "size": 12687840,
      "reboot_required": false,
      "description": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSJ8."
    },
    {
      "id": "d6784baaf602be53256144a13d13ccebfe0dd5110a4cb33a3573fb5e5f7f467f",
      "name": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "version": "CPE6",
      "release_id": "2PY92",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-12-14T07:32:22Z",
      "released": "2022-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09346116M/1/SAS-Drive_Firmware_2PY92_WN64_CPE6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2PY92",
      "size": 12209992,
      "reboot_required": false,
      "description": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n-Initial Release"
    },
    {
      "id": "dc0d64b4e0f55d132b0da94f70c3cee64cc9247c7e1dc514ad7aa4c06e5025cb",
      "name": "Mellanox Windows 64-bit Server OS drivers for Mellanox ConnectX-4 Lx, ConnectX-4,  ConnectX-5, ConnectX-6 and ConnectX-7  Ethernet adapters",
      "version": "03.00.01",
      "release_id": "MXTKX",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2022-10-27T16:33:11Z",
      "released": "2022-09-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08971575M/4/Network_Driver_MXTKX_WN64_03.00.01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MXTKX",
      "size": 74077088,
      "reboot_required": false,
      "description": "This package provides the Windows 64-bit drivers for Mellanox ConnectX-4 Lx, ConnectX-4, ConnectX-5 Ex, ConnectX-6 and ConnectX-7 Ethernet Adapters and is supported on Dell EMC PowerEdge servers with the following operating systems: Window Server 2019 and Windows Server 2022"
    },
    {
      "id": "f4a150703d9d04b786eb6c25b0d0e1f20cf5ddef7c25d7e8e286718875c5648b",
      "name": "Intel NIC Family Version 21.5.0 Drivers for Windows Server 2019 and 2022 Operating Systems",
      "version": "21.5.0",
      "release_id": "7N9PV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2022-09-08T18:05:36Z",
      "released": "2022-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08966610M/2/Network_Driver_7N9PV_WN64_21.5.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7N9PV",
      "size": 44578616,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt."
    },
    {
      "id": "f4cf7ed3313d4f1bc72bbc5656e5a0471af3acfed297fd4c618849e0ba43c298",
      "name": "Mellanox ConnectX-4 Lx Ethernet Adapter Firmware",
      "version": "14.32.20.04",
      "release_id": "XGP2X",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2022-05-17T17:34:13Z",
      "released": "2022-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08558375M/1/Network_Firmware_XGP2X_WN64_14.32.20.04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XGP2X",
      "size": 26607496,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-4 Lx Ethernet Adapters:\n- Mellanox ConnectX-4 Lx Dual Port 25 GbE DA/SFP Network Adapter\n- Mellanox ConnectX-4 Lx Dual Port 25 GbE DA/SFP rNDC\n- Mellanox ConnectX-4 Lx Dual Port 25 GbE Mezzanine card"
    },
    {
      "id": "6b01a365cd3ec211f0220c2550d15f29848832f62579e2e64a7467874c94f2fa",
      "name": "Seagate 4D0C for model number(s) XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "version": "4D0C",
      "release_id": "NX13G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-04-28T10:32:00Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486562M/1/SAS-Drive_Firmware_NX13G_WN64_4D0C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NX13G",
      "size": 11833104,
      "reboot_required": false,
      "description": "This release contains firmware version 4D0C for Seagate drives. Vendor model numbers XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "revision_history": "Fixes:\nFix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can return corrupt data after a power cycle in a corner case.\nFix an issue that can return the sense code 09/80/00 to a WRITE command.\nFix issues that can cause command timeout.\nFix issues that can cause drive assert.\nFix issues that can cause drive hang condition.\nFix an issue that can cause drive-not-ready.\nEnhancements:\nImprove protocol spec compliance.\nImprove throughput performance for specific workloads.\nImprove error logging/sense data reporting."
    },
    {
      "id": "b2ad5c26003b6b9f9d88125c0bb9f808bb0311b85d886d0ee311a83c454a0d95",
      "name": "Mellanox Windows 64-bit Server OS drivers for Mellanox ConnectX-4 Lx, ConnectX-4,  ConnectX-5 and ConnectX-6/DX/LX Ethernet adapters",
      "version": "02.80.02",
      "release_id": "F3Y6R",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2021-12-06T19:52:21Z",
      "released": "2021-12-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07987305M/1/Network_Driver_F3Y6R_WN64_02.80.02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F3Y6R",
      "size": 57737520,
      "reboot_required": false,
      "description": "This package provides the Windows 64-bit drivers for Mellanox ConnectX-4 Lx, ConnectX-4, ConnectX-5 Ex and ConnectX-6/DX/LX Ethernet Adapters and is supported on Dell EMC PowerEdge servers with the following operating systems: Windows Server 2016,Windows Server 2019,Windows Server 2021"
    },
    {
      "id": "0d641577c496dd28e779754196b55a19c1f613a33f3548ee9658a2eb909b215a",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 21.8.2",
      "version": "21.90.2",
      "release_id": "KVNHP",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2021-09-16T23:45:53Z",
      "released": "2021-09-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07742211M/1/Network_Driver_KVNHP_WN64_21.90.2_218.0.300.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KVNHP",
      "size": 36641816,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for Windows Server 2022"
    },
    {
      "id": "80318ba926a22165790009e8aa0a953888eeddac60c085b60146da569d6c5aa9",
      "name": "Intel NIC Family Version 20.5.0 Ethernet Driver",
      "version": "20.5.0",
      "release_id": "2YNFG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2021-07-08T17:20:16Z",
      "released": "2021-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07537990M/1/Network_Driver_2YNFG_WN64_20.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2YNFG",
      "size": 43279168,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update. Please extract the release note \"release.txt\" to find the supported adapters by this software bundle.",
      "revision_history": "Fixes and Enhancements are located in the associated \"release.txt\" file."
    },
    {
      "id": "d79e2b69cd2a5d02a58c27e0a5d7a5446cac3baf930e4d19fc54589ee4e3a887",
      "name": "Intel Youngsville refresh DL69 for model number(s). SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R",
      "version": "DL69",
      "release_id": "2674V",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-07-10T12:54:41Z",
      "released": "2020-04-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06387659M/1/Serial-ATA_Firmware_2674V_WN64_DL69_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2674V",
      "size": 10720968,
      "reboot_required": false,
      "description": "This release contains firmware version DL69 for Intel drives. Vendor model numbers  SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R.",
      "revision_history": "Fixes:\n-SMART attribute shift solution\n-MRR settings to mitigate BJ004 issue\n-Fixes an issue where drive stops responding after soft-reboot following windows install\n\nEnhancements:\nN/A"
    },
    {
      "id": "89ae9090cf2c3897693cf7db47ea51cc4aa7293f3ff7606209debc547f195aab",
      "name": "Samsung SM883 MU SSDR, FW  HF57. Vendor model numbers MZ7KH480HAHQ0D3, MZ7KH960HAJR0D3, MZ7KH1T9HAJR0D3, and MZ7KH3T8HALS0D3.",
      "version": "HF57",
      "release_id": "NKCP0",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-05-07T05:31:41Z",
      "released": "2020-01-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06251766M/1/Serial-ATA_Firmware_NKCP0_WN64_HF57_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKCP0",
      "size": 11964936,
      "reboot_required": false,
      "description": "This release contains firmware version HF57 for vendor model numbers MZ7KH480HAHQ0D3, MZ7KH960HAJR0D3, MZ7KH1T9HAJR0D3, and MZ7KH3T8HALS0D3",
      "revision_history": "Fixes:\n- Corrected condition where drive entered ERRORMOD when connected to power without signal cable.\n- Other corrections for CMD 63h/64h/65h handling and TRIM commands.\n\nEnhancements:\nN/A"
    },
    {
      "id": "609b347d6db6adddc3da0bce659cb43540fd91cc2c8026137d54da0718215054",
      "name": "Micron J404 for model number(s)MTFDDAK3T8TDS and MTFDDAK3T8TDT .",
      "version": "J404",
      "release_id": "PXMD3",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-05-06T11:42:43Z",
      "released": "2020-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06250506M/1/Serial-ATA_Firmware_PXMD3_WN64_J404_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PXMD3",
      "size": 10671976,
      "reboot_required": false,
      "description": "This release contains firmware version J404 for Micron drives. Vendor model numbers MTFDDAK3T8TDS and MTFDDAK3T8TDT.",
      "revision_history": "Fixes:\n-Initial Release\n\nEnhancements:\n-Initial Release"
    },
    {
      "id": "58e470a3032c8ff9009e2bb6c65a75ddecbc0354b7c137886ab0c977f528e9a6",
      "name": "Mellanox Windows 64-bit Server OS drivers for Mellanox ConnectX-4 Lx, ConnectX-4 and ConnectX-5 Ethernet adapters",
      "version": "02.030.03",
      "release_id": "J3CPP",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2020-02-12T20:29:15Z",
      "released": "2020-02-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06091075M/1/Network_Driver_J3CPP_WN64_02.030.03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J3CPP",
      "size": 45622304,
      "reboot_required": false,
      "description": "This package provides the Windows 64-bit drivers for Mellanox ConnectX-4 Lx, ConnectX-4 and  ConnectX-5 Ethernet Adapters and is supported on Dell EMC PowerEdge servers with the following operating systems: Windows Server 2016 and Window Server 2019",
      "revision_history": "Fixes:\n- Fixed an issue where the number of MSI-X reported by the command \"mlx5cmd -vfresource\" on a Virtual Machine was wrong.\n- Fixed an issue where the values of registry keys that can be changed dynamically were not included in get-netview report.\n\nEnhancements:\n- NIC Teaming: NIC Teaming allows you to group between one and 32 physical Ethernet network adapters into one or more software-based virtual network adapters.\n- Zero Touch RoCE enables RoCE to operate on fabrics where no PFC nor ECN are configured. This makes RoCE configuration a breeze while still maintaining its superior high performance.\n- Added new diagnostic counter for Zero Touch RoCE.\n- Added a new parameter to configure Zero Touch RoCE Facilities.\n- ETL: Changed max size of ETL files to 500MB\n- Added a counter for packets that their checksum was calculated by software.\n- Renamed the RoceMaxFrameSize registry keys to RoceFrameSize and updated its values.\n- Added a new performance registry key (MaxCallsToNdisIndicate).\n- [Alpha] Added support for ConnectX-6 200GbE link speed only when in Force mode (non-Auto-Negotiation).\n- Updated several ConnectX-6 adapter cards description displayed in the Device Manager window."
    },
    {
      "id": "7e7c2ffa498d19bce1d0e339a973e6cf2d114adff2bb72ec2842e3c96dd568f7",
      "name": "Mellanox ConnectX-4 Ethernet Adapter Firmware",
      "version": "12.26.60.00",
      "release_id": "TM1GG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-02-12T19:25:03Z",
      "released": "2020-02-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06090964M/1/Network_Firmware_TM1GG_WN64_12.26.60.00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TM1GG",
      "size": 18047584,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-4 Dual Port 100 GbE Ethernet QSFP Network Adapter",
      "revision_history": "Fixes:\n- Fixed an issue that cause the firmware to hang when an FLR occurred at the same time as the teardown. As a result, the teardown flow took a lock, and never released it because it was being aborted by an FLR.\n- Creating an NVMoF offloaded target while running the LFWP flow may cause the device to become unstable.\n- Fixed an issue that caused IPoIB not to function when there were DC CNAK QPs active.\n\nEnhancements:\n- [Alpha]  ECN is now automatically copied from the inner header to the outer header, unless defined otherwise in the SW steering. To disable this feature, need to write to the NV_SW_OFFLOAD_CONFIG file.\n- The eth_link_down_counter now counts logical link downs as well."
    },
    {
      "id": "8b261aa1080cecb64c8ca48e687208602108b4d5ae173c8fa46965296fc0a633",
      "name": "Matrox Video Driver",
      "version": "4.4.0.4",
      "release_id": "N1HM4",
      "category": "Video",
      "category_slug": "video",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2019-10-22T05:43:09Z",
      "released": "2018-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05278833M/5/Video_Driver_N1HM4_WN64_4.4.0.4_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N1HM4",
      "size": 6189248,
      "reboot_required": true,
      "description": "This package contains the Matrox Video driver. A graphics or video driver is the software that enables communication between the graphics card and the operating system, games, and applications.",
      "revision_history": "Initial Release"
    }
  ]
}