{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "xe7740",
  "name": "XE7740",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge XE7740 Express Flash PCIe SSD Updates",
  "filter": "express-flash-pcie-ssd",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 3,
      "rss": "/xe7740/urgent/rss.xml",
      "api": "/api/xe7740/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 9,
      "rss": "/xe7740/recommended/rss.xml",
      "api": "/api/xe7740/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 15,
      "rss": "/xe7740/optional/rss.xml",
      "api": "/api/xe7740/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/xe7740/bios/rss.xml",
      "api": "/api/xe7740/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/xe7740/boss/rss.xml",
      "api": "/api/xe7740/boss"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/xe7740/diagnostics/rss.xml",
      "api": "/api/xe7740/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/xe7740/drivers-for-os-deployment/rss.xml",
      "api": "/api/xe7740/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 8,
      "rss": "/xe7740/express-flash-pcie-ssd/rss.xml",
      "api": "/api/xe7740/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/xe7740/firmware/rss.xml",
      "api": "/api/xe7740/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/xe7740/idrac/rss.xml",
      "api": "/api/xe7740/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 10,
      "rss": "/xe7740/network/rss.xml",
      "api": "/api/xe7740/network"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/xe7740/security/rss.xml",
      "api": "/api/xe7740/security"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/xe7740/systems-management/rss.xml",
      "api": "/api/xe7740/systems-management"
    }
  ],
  "count": 8,
  "updates": [
    {
      "id": "9908629a3c6dc68fa7bd50152775a1b55d88d11e66dbd615cc0ee12ee6f32e5c",
      "name": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "HJ15N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-07T10:29:04Z",
      "released": "2025-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14393389M/1/Express-Flash-PCIe-SSD_Firmware_HJ15N_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HJ15N",
      "size": 28267144,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "revision_history": "Fixes:\nN/A - Initial Release\n\nEnhancements:\nN/A - Initial Release"
    },
    {
      "id": "e9e9eb671e92cd921c95ee81a720d782a743494a17f867dc220bdd4d6ece6d62",
      "name": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release",
      "version": "1.1.0",
      "release_id": "WHGGM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-12-16T15:33:37Z",
      "released": "2025-12-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13989869M/1/Express-Flash-PCIe-SSD_Firmware_WHGGM_WN64_1.1.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WHGGM",
      "size": 32600864,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "b754ee9995478931a7e3db24fac2b5d6da978e45ebe6ee18ead87a3f53454fd4",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 E3.S ISE Firmware Maintenance Release",
      "version": "2.0.1",
      "release_id": "FFWM2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-18T10:25:59Z",
      "released": "2025-03-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12654447M/3/Express-Flash-PCIe-SSD_Firmware_FFWM2_WN64_2.0.1_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FFWM2",
      "size": 29016368,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n1. Fix the bug that write index of SMBus ring buffer was out of sync.\n2. For PCI Information such as PCI Vendor ID other than BDF, FW also keeps their value. So, fixed to respond the value directly from FW instead of getting them from HW.\n3. With current FW, host should use AUSE=1 to run Block Erase in Sanitize command. If block erase failed, host can use Exit failure mode to release the failure status\n4. FW is fixed to enable the SRAM 1-bit error correction feature during the initialization of the SoC.\n5. Modify the drive FW to re-allocate the DRAM range for VDM to eliminate the arbiter from being locked when three different DRAM Wr access (one is for VDM) come in simultaneously.\n\nEnhancements:  \nN/A"
    },
    {
      "id": "1c33160daccea25862c0868752c3f6de3029d3fbed1f0c2ff3803d0ef3b0753d",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 E3.S FIPS Firmware Maintenance Release",
      "version": "3.0.2",
      "release_id": "VN92N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-23T17:03:52Z",
      "released": "2025-04-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13157817M/1/Express-Flash-PCIe-SSD_Firmware_VN92N_WN64_3.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VN92N",
      "size": 29958320,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 E3.S FIPS Firmware Maintenance Release",
      "revision_history": "Fixes:  \nTo be Added."
    },
    {
      "id": "6afe093e100584c1939aa6464f00d6bc0518318675009d522eb2afad6b7ad7c5",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 E3.S ISE Firmware Release",
      "version": "1.0.2",
      "release_id": "5GTC9",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-13T00:42:16Z",
      "released": "2025-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12850492M/1/Express-Flash-PCIe-SSD_Firmware_5GTC9_WN64_1.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5GTC9",
      "size": 30929456,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 E3.S ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any RHEL and Ubuntu OS. Either use Windows SLES or iDRAC for FW update - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "7be90932a9eca915194db12b4b54c6e2d1dfaf50ecc4c79c27b1761682ea45d0",
      "name": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "version": "2.5.0",
      "release_id": "4P5K1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-07-03T13:05:39Z",
      "released": "2024-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11804735M/1/Express-Flash-PCIe-SSD_Firmware_4P5K1_WN64_2.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4P5K1",
      "size": 7724464,
      "reboot_required": false,
      "description": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "revision_history": "Fixes:\n\n- FW introduces multiple fixes and enhancements."
    },
    {
      "id": "8b797d2033075b5fcc501cb105ea8dce3857c0f835f3ca625c073e44b6a5813c",
      "name": "Hynix 1.1.0 FW for PE9010 NVMe drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "version": "1.1.0",
      "release_id": "CDKNW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-05T17:47:40Z",
      "released": "2024-01-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11092654M/1/Express-Flash-PCIe-SSD_Firmware_CDKNW_WN64_1.1.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CDKNW",
      "size": 12225320,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.1.0 for Hynix PE9010 NVMe SSD drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "revision_history": "FW to provide performance improvements."
    }
  ]
}
