{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "t150",
  "name": "T150",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge T150 Urgent Updates",
  "filter": "urgent",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 42,
      "rss": "/t150/urgent/rss.xml",
      "api": "/api/t150/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 104,
      "rss": "/t150/recommended/rss.xml",
      "api": "/api/t150/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 28,
      "rss": "/t150/optional/rss.xml",
      "api": "/api/t150/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/t150/bios/rss.xml",
      "api": "/api/t150/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/t150/chipset/rss.xml",
      "api": "/api/t150/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/t150/diagnostics/rss.xml",
      "api": "/api/t150/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/t150/drivers-for-os-deployment/rss.xml",
      "api": "/api/t150/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 3,
      "rss": "/t150/express-flash-pcie-ssd/rss.xml",
      "api": "/api/t150/express-flash-pcie-ssd"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/t150/idrac/rss.xml",
      "api": "/api/t150/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 14,
      "rss": "/t150/network/rss.xml",
      "api": "/api/t150/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 71,
      "rss": "/t150/sas-drive/rss.xml",
      "api": "/api/t150/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 10,
      "rss": "/t150/sas-non-raid/rss.xml",
      "api": "/api/t150/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 17,
      "rss": "/t150/sas-raid/rss.xml",
      "api": "/api/t150/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 51,
      "rss": "/t150/serial-ata/rss.xml",
      "api": "/api/t150/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/t150/systems-management/rss.xml",
      "api": "/api/t150/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/t150/video/rss.xml",
      "api": "/api/t150/video"
    }
  ],
  "count": 42,
  "updates": [
    {
      "id": "441f01efc24fdb35921daa676e2ee39d68fa1f5699a3621c00dad8bbe0709096",
      "name": "Dell Server PowerEdge BIOS R350/R250/T350/T150 Version 1.18.3",
      "version": "1.18.3",
      "release_id": "NY16D",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-11-06T03:27:20Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15211345M/2/BIOS_NY16D_WN64_1.18.3.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NY16D",
      "size": 39624024,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced features sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Enhancements\n- This product release contains security update DSA-2026-470, DSA-2026-471. Any security fix information will be accessible on the Dell Security Advisories and Notices website."
    },
    {
      "id": "e58d7019c0b7785a612c738ba97f93e860f0f4e761c91716fbe9c1166aec3a2b",
      "name": "iDRAC 7.30.30.54",
      "version": "7.30.30.54",
      "release_id": "P3PPC",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-12T06:04:52Z",
      "released": "2026-08-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14890481M/1/iDRAC-with-Lifecycle-Controller_Firmware_P3PPC_WN64_7.30.30.54_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P3PPC",
      "size": 246711768,
      "reboot_required": false,
      "description": "The Integrated Dell Remote Access Controller (iDRAC) is designed to make server administrators more productive and improve the overall availability of Dell servers. iDRAC also provides an out-of-band mechanism for configuring the platform, applying firmware updates, saving or restoring a system backup, or deploying an operating system, either by using a GUI or a remote scripting language, such as Redfish or RACADM.",
      "revision_history": "Fixes:\n\n- Resolved an issue that could cause Active Directory authentication to fail after upgrading to iDRAC firmware version 7.30.30.51 when the Global Catalog Lookup (GCLookupEnable) option is enabled.\n\n- Resolved an issue where local Smart Card authentication could fail when uploaded user certificates used LF-only line endings.\n\n- Resolved an issue that could cause the DelliDRACCardService.ImportCertificate Redfish operation to fail when processing certain Base64-encoded certificate payloads.\n\n- Corrected link-status reporting for the Broadcom BCM57504 OCP 3.0 network adapter, providing more accurate link-state visibility and management.\n\n- Resolved an issue on PowerEdge XR8620T systems where processors could enter an unintended throttling state due to external PROCHOT assertions following an iDRAC firmware update.\n\n- Improved firmware update applicability detection for Samsung PM1733a NVMe SSDs. iDRAC now correctly identifies applicable Dell Update Package (DUP) firmware files when they match the installed drive inventory.\n\n- Improved storage controller management reliability by resolving a memory leak during RAID population processing, helping reduce long-term resource consumption.\n\n- Resolved an intermittent issue that could cause Technical Support Report (TSR) collection jobs to fail during log generation or retrieval.\n\n- Enhanced firmware update security by enforcing HTTPS certificate validation during iDRAC Simple Update operations when retrieving update packages from remote locations.\n\nEnhancements:\n\n- N/A"
    },
    {
      "id": "0a6a479d8442052f0ed7ecbee39b76740eab0e8b746a305ff6194e3d7220e695",
      "name": "Seagate Evans Firmware Version ESLA  for model number(s)  ST10000NM011G, ST12000NM009G, ST14000NM013G,ST16000NM010G",
      "version": "ESLA",
      "release_id": "T16JN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-10T04:27:32Z",
      "released": "2026-08-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14878500M/1/SAS-Drive_Firmware_T16JN_WN64_ESLA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T16JN",
      "size": 27626464,
      "reboot_required": false,
      "description": "Firmware Update of \"ESLA\" for Evans SAS ISE HDD.  Model numbers: ST10000NM011G, ST12000NM009G, ST14000NM013G, and ST16000NM010G.",
      "revision_history": "- FW change to address potential Drive Assert by updating the cleanup logic to handle the interrupted write data frame when the host queue happens to be active during termination cleanup sequence."
    },
    {
      "id": "05aaf2787b94f4c3658352e334d92a069cdbd2bc57150c8d9513a2190745fc22",
      "name": "This release contains firmware version CSLF for STX drives. Vendor model numbers ST6000NM035A, ST8000NM014A.",
      "version": "CSLF",
      "release_id": "C4W12",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-10T04:01:33Z",
      "released": "2026-08-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14878306M/1/SAS-Drive_Firmware_C4W12_WN64_CSLF_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C4W12",
      "size": 27698568,
      "reboot_required": false,
      "description": "Firmware Refresh of \"CSLF\" for Seagate Cimarron 512e ISE.  Vendor model number ST6000NM035A, ST8000NM014A.",
      "revision_history": "- FW change to address potential Drive Assert by updating the cleanup logic to handle the interrupted write data frame when the host queue happens to be active during termination cleanup sequence."
    },
    {
      "id": "559e792d7369318d22be9a9b8c82cb7c3e6f91193952b11ebf8a9ba38e90ab7c",
      "name": "Toshiba EF0A for model number(s) AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY",
      "version": "EF0A",
      "release_id": "THG5M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T06:27:04Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607520M/2/SAS-Drive_Firmware_THG5M_WN64_EF0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=THG5M",
      "size": 26661096,
      "reboot_required": false,
      "description": "This release contains firmware version EF0A for Toshiba drives. Vendor model numbers AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures.\n- Fixed Command timeout (or 06/29/04) issue.\n  This problem may occur when the queued time for a read or write command \n  exceeds the Command Aging Timer and the SYNCHRONIZED CACHE \n  command is also queued.\n- Fixed random write iops degradation after sequential read.\n    4k Random write -\u003e Seq read -\u003e 4k random write. In this test sequence, \n    2nd 4k random write iops may drop.\n- Fixed a wrong LBA report in SENSE DATA when Read Buffer CRC \n    error(03/11/02) occurs."
    },
    {
      "id": "fdd84063aa261dc77f4bd896bc2458570e08fd9fa0f7c7a07d843154dbc72955",
      "name": "Initial release of Toshiba AL15SE+ HDD Model Number AL15SEB09EQY",
      "version": "EF82",
      "release_id": "VJWX0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T04:21:30Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607338M/2/SAS-Drive_Firmware_VJWX0_WN64_EF82_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJWX0",
      "size": 26660216,
      "reboot_required": false,
      "description": "This release contains firmware version EF82 for Toshiba drives. Vendor Model Number AL15SEB09EQY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures."
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "b3756f56e76fb6fdf6d53d9bc0bb41fa37aaf9ec858ba959301334044cd538e7",
      "name": "DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR",
      "version": "DL7C",
      "release_id": "VJPKG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-08-19T07:07:49Z",
      "released": "2025-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12600340M/4/Serial-ATA_Firmware_VJPKG_WN64_DL7C_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJPKG",
      "size": 22988728,
      "reboot_required": false,
      "description": "This is a firmware release for DELLSLDM Youngsville-RR  DL7C firmware for Model number(s) SSDSC2KB240GZR, SSDSC2KB480GZR, SSDSC2KB960GZR, SSDSC2KB019TZR, SSDSC2KB038TZR, SSDSC2KB076TZR, SSDSCKKB240GZR, SSDSCKKB480GZR,SSDSC2KG480GZR, SSDSC2KG960GZR, SSDSC2KG019TZR, SSDSC2KG038TZR",
      "revision_history": "Issue: During a warm Reboot the YVRR drive may intermittently disappear when connected to the PERC H965i\nFix: DL7C FW now addresses this issue\nIssue: PLI capacitor charge flag not set leads drive to enter disable logical mode\nFix: DL7C FW now addresses this issue"
    },
    {
      "id": "ceff23d80cbb8541baa365b1fd0640fa4a06d13481f5404c1fc5497f6dbd404c",
      "name": "Seagate SSC8 for model number(s) ST1200MM0069",
      "version": "SSC8",
      "release_id": "P9R4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:08:58Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11500432M/2/SAS-Drive_Firmware_P9R4D_WN64_SSC8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P9R4D",
      "size": 24522608,
      "reboot_required": false,
      "description": "This release contains firmware version SSC8 for Seagate drives. Vendor model numbers ST1200MM0069..",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "c2499ab3befc7f8aac45f1eb2b078813e866b63b701d8296d5628475a85b6e14",
      "name": "HGST NS11 for model number(s) HUH721212AL5200 and HUH721212AL4200",
      "version": "NS11",
      "release_id": "04PM5",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:07:34Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12029572M/2/SAS-Drive_Firmware_04PM5_WN64_NS11_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=04PM5",
      "size": 24602048,
      "reboot_required": false,
      "description": "This release contains firmware version NS11 for HGST drives. Vendor model numbers HUH721212AL5200 and HUH721212AL4200.\nFW update for WDC Leo-A 512e SAS HDD, Model number HUH721212AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes. \n'FW update for WDC Leo-A 4Kn SAS HDD, Model number HUH721212AL4200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "6cb9b2e14559a89fe993a07e8c8367a371dc1253168afd133677270b5bcb3eec",
      "name": "Seagate ST38 for model number(s) ST600MM0069 and ST1200MM0099",
      "version": "ST38",
      "release_id": "FFN16",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T10:22:22Z",
      "released": "2024-05-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11502881M/2/SAS-Drive_Firmware_FFN16_WN64_ST38_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FFN16",
      "size": 24522520,
      "reboot_required": false,
      "description": "This release contains firmware version ST38 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes:\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "2189d3c19f564af9c4adadb58dd81c7b80feda3edd4af1e38e757fc10724ae62",
      "name": "HGST EU46  for model number(s) HUC156030CSS200 and HUC156060CSS200",
      "version": "EU46",
      "release_id": "R39JH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T09:18:31Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12886071M/1/SAS-Drive_Firmware_R39JH_WN64_EU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R39JH",
      "size": 24103776,
      "reboot_required": false,
      "description": "This release contains firmware version EU46 FW changes to affect HGST King Cobra F 512n SAS ISE HDD, Model numbers HUC156060CSS200 and HUC156030CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "710a41520969170b139a0ad46b68638dc89b3cc9bed271ae5f33137141cd804d",
      "name": "HGST EK46 for model number(s) HUC156060CS4204",
      "version": "EK46",
      "release_id": "M04KK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T07:22:10Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12885013M/1/SAS-Drive_Firmware_M04KK_WN64_EK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M04KK",
      "size": 24112472,
      "reboot_required": false,
      "description": "This release contains firmware version EK46 'FW changes to affect HGST King Cobra F 4Kn SAS HDD, Model number HUC156060CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "be8cba2fe69053e9785264bea3fc29c4b30fe84a8cd65e095c114f2e7bbbf350",
      "name": "HGST EJ46  for model number(s) HUC156030CSS204,and HUC156060CSS204",
      "version": "EJ46",
      "release_id": "H53FC",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T06:20:55Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12884528M/1/SAS-Drive_Firmware_H53FC_WN64_EJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H53FC",
      "size": 24103728,
      "reboot_required": false,
      "description": "This release contains firmware version EJ46 'FW changes to affect HGST King Cobra F 512n SAS HDD, Model numbers HUC156060CSS204 and HUC156030CSS204.\nIncludes FW change to turn off drive usage logging to avoid pointer error",
      "revision_history": "Fixes:\nFixes: FW change to turn off drive usage logging to avoid pointer error"
    },
    {
      "id": "c69c0d7de49ad38ad0c52ed4cc69e17677fb3881869c747bd9a110e6b4c8bb73",
      "name": "HGST FU46  for model number(s) HUC101830CSS200, HUC101812CSS200 and HUC101860CSS200",
      "version": "FU46",
      "release_id": "DH7TM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T11:00:24Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880083M/1/SAS-Drive_Firmware_DH7TM_WN64_FU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DH7TM",
      "size": 24083696,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512n SAS ISE HDD, Model numbers  HUC101830CSS200, HUC101860CSS200, and HUC101812CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "cd1d62fa296afde305b57d1c8c09a670b8c62765e8c4a61a2570f61f4ffede28",
      "name": "HGST FK46 for model number(s) HUC101818CS4204 and HUC101818CS4204",
      "version": "FK46",
      "release_id": "V917M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T10:23:21Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880005M/1/SAS-Drive_Firmware_V917M_WN64_FK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V917M",
      "size": 24091240,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512e and 4Kn SAS HDD , Model number HUC101818CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\n'FW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "2f758b11765da0fb1b02a4e543dc569c690272a2b0b6e0aa0bfc0776af21817b",
      "name": "HGST FJ46  for model number(s) HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204",
      "version": "FJ46",
      "release_id": "DYYN1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T09:12:02Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12879555M/1/SAS-Drive_Firmware_DYYN1_WN64_FJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DYYN1",
      "size": 24083632,
      "reboot_required": false,
      "description": "This release contains FW changes to affect HGST Cobra F 512n SAS HDD, Model numbers HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204 includes FW change to turn off drive usage logging to avoid pointers error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointers error."
    },
    {
      "id": "065fa4836a3f37c80b73880763125794567bd147de5257395c832ecef2926d1c",
      "name": "HGST NT11 for model number  HGST HUH721212ALE600.",
      "version": "NT11",
      "release_id": "JCYF6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-08-22T16:02:52Z",
      "released": "2024-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12015624M/1/Serial-ATA_Firmware_JCYF6_WN64_NT11_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JCYF6",
      "size": 13351208,
      "reboot_required": false,
      "description": "This release contains firmware version NT11 for HGST drives. Vendor model number HUH721212ALE600.\nFW update for WDC Leo-A 512e SATA HDD, Model number HUH721212ALE600.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance."
    },
    {
      "id": "632cefa984ce903c90ae86afbe7b607b60915f5c751fe564c63e5b134b5be866",
      "name": "HGST NM11 for model number(s) HUH721212AL5205",
      "version": "NM11",
      "release_id": "M6T4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-08-22T15:02:58Z",
      "released": "2024-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12015224M/1/SAS-Drive_Firmware_M6T4D_WN64_NM11_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M6T4D",
      "size": 13326064,
      "reboot_required": false,
      "description": "This release contains firmware version NM11 for HGST drives. Vendor model numbers HUH721212AL5205 of capacity 12TB.\n\"FW update for WDC Leo-A 512e SAS FIPS HDD, Model number HUH721212AL5205.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.\"",
      "revision_history": "\"-Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance\""
    },
    {
      "id": "2d691ed72b31c474544f0a9a0818d69f0e4ab820992ea73115f41143fafef850",
      "name": "WD BCQ firmware G138  for model numbers WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200,WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200,WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200",
      "version": "G138",
      "release_id": "8W5WF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T07:34:09Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11655805M/1/SAS-Drive_Firmware_8W5WF_WN64_G138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8W5WF",
      "size": 12585960,
      "reboot_required": false,
      "description": "This release contains firmware version G138 for WD BCQ drives. Vendor model numbers WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200, WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200, WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries."
    },
    {
      "id": "13796d98c89ff1cc8cda76d598f7dfe5ccc925a8fadfd3999fb71e9fbcb079fb",
      "name": "WDC Bear Cove Quantum FIPS-140 L138 for 1WPD and 3WPD  model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205,WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "version": "L138",
      "release_id": "16C85",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T05:58:21Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11654668M/1/SAS-Drive_Firmware_16C85_WN64_L138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=16C85",
      "size": 12580296,
      "reboot_required": false,
      "description": "This release contains firmware version L138 for WDC Bear Cove Quantum FIPS-140 1WPD and 3WPD. For model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205, WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "ec7b4413408504ee11e7cc02edb1960d318d54ce4c0cfc3635ef7ba19403b254",
      "name": "SK HYNIX DE08 for model numbers HFS960G32FEH-7A10A, HFS1T9G32FEH-7A10A, HFS3T8G32FEH-7410A and HFS480G32FEH-7410A",
      "version": "DE08",
      "release_id": "3DTV4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T03:52:03Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11629605M/1/Serial-ATA_Firmware_3DTV4_WN64_DE08_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3DTV4",
      "size": 13594832,
      "reboot_required": false,
      "description": "This release contains firmware version DE08 for SK HYNIX model numbers HFS960G32FEH-7A10A, HFS1T9G32FEH-7A10A, HFS3T8G32FEH-7410A and HFS480G32FEH-7410A.",
      "revision_history": "Fix: \n\n- Improvements made to Background Scanning functionality"
    },
    {
      "id": "333f510745d6bedcbadf00dfa27e5b7532c32ae94fea09bd9ec4a93617b1329f",
      "name": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s)  KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960",
      "version": "CA0C",
      "release_id": "1YD58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T15:53:43Z",
      "released": "2023-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10810459M/2/SAS-Drive_Firmware_1YD58_WN64_CA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1YD58",
      "size": 12708760,
      "reboot_required": false,
      "description": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s) KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960G.",
      "revision_history": "Fixes: \nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed in a different area, the drive may encounter the below failure mode. Once a drive falls into this failure mode, it cannot be recovered by power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. Data buffer is used for data transfer during Wear-Leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow.                                                                                                             Write Cache Issue: An issue that may cause firmware downloads to fail in the event of a capacitor failure. This failure is triggered by firmware download in the Write Cache Off state, and even if it occurs, it does not lead to drive failure and can be recovered by a reset or Power cycle.\nCause: When FW Update is executed in the Write Cache Off state and then restarted, capacitor discharge control is activated. In this case, unintended PLP occurs because capacitor discharge was controlled in the order of capacitor discharge and then PLP interrupt mask.\nFix: When capacitor discharge control is executed after FW Update in the Write Cache Off state and the system is restarted, the PLP interrupt mask is changed to control in the order of PLP interrupt mask and then capacitor discharge."
    },
    {
      "id": "a1178484b04285ac191ec9219242d56e944c47e79f02b74de40e05534be8c7b3",
      "name": "Seagate SBW6 for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "version": "SBW6",
      "release_id": "5G3PW",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T06:30:37Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11496475M/1/SAS-Drive_Firmware_5G3PW_WN64_SBW6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5G3PW",
      "size": 13261504,
      "reboot_required": false,
      "description": "This release contains firmware version SBW6 Seagate for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "revision_history": "Fixes:\n\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "8b123fe887879d8ad789dc986b35da9f2ec22affe26654a6bb6e8b20640f3cc6",
      "name": "Windows Server 2019 64bit driver for PERC S150 Controller",
      "version": "6.7.0.0003",
      "release_id": "XVCP2",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T16:00:59Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422723M/1/SAS-RAID_Driver_XVCP2_WN64_6.7.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XVCP2",
      "size": 6625104,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S150 Controller"
    },
    {
      "id": "fda7ed85944e9d8962289de66a326eff2cd94be829b58a3bdef99383702c6311",
      "name": "Toshiba EE0A for model number(s) AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "version": "EE0A",
      "release_id": "50N1P",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-13T11:38:43Z",
      "released": "2022-04-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08344514M/2/SAS-Drive_Firmware_50N1P_WN64_EE0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=50N1P",
      "size": 12543400,
      "reboot_required": false,
      "description": "This release contains firmware version EE0A for Toshiba drives. Vendor model numbers AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "revision_history": "Fixes:\n- Improvements that reduce the risk of media errors"
    },
    {
      "id": "8b7171c9e267a84502b4dd3b631bc09cc0e0ab25b12cc110d8273af3b0f84615",
      "name": "Seagate 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "version": "4S0C",
      "release_id": "G04C8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-12T12:12:27Z",
      "released": "2022-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08459420M/2/SAS-Drive_Firmware_G04C8_WN64_4S0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G04C8",
      "size": 12625072,
      "reboot_required": false,
      "description": "This release contains Seagate firmware version 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "revision_history": "Fixes:\n-Fix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\n-Fix an issue that can return corrupt data after a power cycle in a corner case.\n-Fix an issue that can return the sense code 09/80/00 to a WRITE command.\n-Fix issues that can cause command timeout.\n-Fix issues that can cause drive assert.\n-Fix issues that can cause drive hang condition.\n\nEnhancements:\n-Improve protocol spec compliance.\n-Improve throughput performance for specific workloads.\n-Improve error logging/sense data reporting.\n-\nFix an issue that can cause drive-not-ready."
    },
    {
      "id": "011cdb21bdfbaa51a2cf874a7f8ca3a3e056524999b2d1a596b114d27e7ea2fc",
      "name": "Seagate CAJD for model numbers ST1000NM004A-2MN130, ST2000NM012A-2MP130, ST4000NM016A-2HZ130",
      "version": "CAJD",
      "release_id": "RWK48",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-31T07:56:25Z",
      "released": "2024-01-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11201542M/1/Serial-ATA_Firmware_RWK48_WN64_CAJD_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RWK48",
      "size": 12823344,
      "reboot_required": false,
      "description": "This release contains firmware version CAJD for STX model numbers ST1000NM004A-2MN130, ST2000NM012A-2MP130, ST4000NM016A-2HZ130. Capacity of 1TB,2TB, and 4TB",
      "revision_history": "Fixes: \n- Fix for high load/unload count with host read device statistics log upon wake up from Idle2.\n- Fix for potential write uncorrectable error in Write Log Page for Non-Volatile Cache."
    },
    {
      "id": "7d98bb95a79ce046742b0e7a9a29f34daca02fb5fe008896efcc9775bdddcafc",
      "name": "HGST KV45  for model number(s) HGST HUS726020ALA610 and HGST HUS726040ALA610.",
      "version": "KV45",
      "release_id": "X59KC",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-23T17:40:36Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150839M/2/Serial-ATA_Firmware_X59KC_WN64_KV45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X59KC",
      "size": 12403400,
      "reboot_required": false,
      "description": "This release contains the firmware revision HGST KV45  for Aries K Plus drive model number(s) HGST HUS726020ALA610 and HGST HUS726040ALA610.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "121c2c65e1e9a03b00d25ba579c34f484234d576609fe0ed7e6c5860d47a0e0b",
      "name": "Samsung PM1643a drives for FW DSA4 for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "version": "DSA4",
      "release_id": "D7RNT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:05:17Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08612628M/2/SAS-Drive_Firmware_D7RNT_WN64_DSA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D7RNT",
      "size": 11328112,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1643a drives for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "5d8c2335761f5dc729d22a939ccc164e23f6c99632d2615b1482961702fec308",
      "name": "HGST KU45  for model number(s) HUS726020ALS210 and HUS726040ALS210.",
      "version": "KU45",
      "release_id": "68X4C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T17:03:19Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150772M/2/SAS-Drive_Firmware_68X4C_WN64_KU45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=68X4C",
      "size": 11746544,
      "reboot_required": false,
      "description": "This release contains firmware version KU45  for HGST drives. Vendor model numbers HUS726020ALS210 and HUS726040ALS210.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "3e6433d387935a61626c4c49d78e992bbd48dcbd023e5e824374f6c97ced803b",
      "name": "PERC H740P/ H745 RAID Controller Firmware 51.16.0-5150",
      "version": "51.16.0-5150",
      "release_id": "96M5G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-09-29T13:41:58Z",
      "released": "2023-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10676343M/1/SAS-RAID_Firmware_96M5G_WN64_51.16.0-5150_A17.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=96M5G",
      "size": 21963976,
      "reboot_required": true,
      "description": "This release updates the firmware residing on PERC H740P, H840, and H745 controllers to package 51.16.0-5150",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions.\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown of the system to enable the new memory settings. A warm reboot will NOT activate the updated settings. If iDrac/LC is used to perform the update, a graceful shutdown after the update is still required.\n\nFirmware downgrade below 50.3.0-1022 is not supported without assistance from Dell due to the potential of data loss if steps are not performed correctly.\n-Call Dell technical support for guidance if this is required.\n\nFirmware downgrade from version 50.5.0-1750 or greater to a lower version while in Enhanced -HBA mode is not supported.\nFirmware downgrade from version 50.5.1-2633 or greater to a lower version while in OpenManage Secure Enterprise Key Manager mode is not supported.\n-H745 PERC controllers only support firmware version 50.9.2-2938 or greater"
    },
    {
      "id": "464b59fe39812588c5713e0530dbe62d1c68c051dda5e2cf1656c70d85840571",
      "name": "Micron 5300 SED J808 firmware for model number MTFDDAK7T6TDS",
      "version": "J808",
      "release_id": "7X7KX",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-08-04T09:11:19Z",
      "released": "2023-08-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10433234M/1/Serial-ATA_Firmware_7X7KX_WN64_J808_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7X7KX",
      "size": 11866584,
      "reboot_required": false,
      "description": "This  release contains  firmware for Micron 5300 SED drives (7.68TB capacity).  Firmware version J808 for Micron 5300 SED drives, model MTFDDAK7T6TDS..",
      "revision_history": "Fixes:\n-Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "27ea407c83dc92f02b1d6fd8458331571b111a4b1b8b129f7c9a8b86e7c4f1ef",
      "name": "Toshiba EJ09 for MG08 model number(s) MG08SCA16TEY",
      "version": "EJ09",
      "release_id": "9N3RR",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-08-18T08:52:06Z",
      "released": "2022-08-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08893938M/1/SAS-Drive_Firmware_9N3RR_WN64_EJ09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9N3RR",
      "size": 12479016,
      "reboot_required": false,
      "description": "This release contains firmware version EJ09 for MG08 model number(s) MG08SCA16TEY.",
      "revision_history": "Fixes:-\nAddresses an issue that could cause occasional read errors"
    },
    {
      "id": "6b01a365cd3ec211f0220c2550d15f29848832f62579e2e64a7467874c94f2fa",
      "name": "Seagate 4D0C for model number(s) XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "version": "4D0C",
      "release_id": "NX13G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-04-28T10:32:00Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486562M/1/SAS-Drive_Firmware_NX13G_WN64_4D0C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NX13G",
      "size": 11833104,
      "reboot_required": false,
      "description": "This release contains firmware version 4D0C for Seagate drives. Vendor model numbers XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "revision_history": "Fixes:\nFix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can return corrupt data after a power cycle in a corner case.\nFix an issue that can return the sense code 09/80/00 to a WRITE command.\nFix issues that can cause command timeout.\nFix issues that can cause drive assert.\nFix issues that can cause drive hang condition.\nFix an issue that can cause drive-not-ready.\nEnhancements:\nImprove protocol spec compliance.\nImprove throughput performance for specific workloads.\nImprove error logging/sense data reporting."
    },
    {
      "id": "2ea2748e5a817413862cea6456c7c329059a045806cd1465168a7274a04871f0",
      "name": "Seagate PT55 for model number(s) ST8000NM0185.",
      "version": "PT55",
      "release_id": "6421F",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-12-15T06:15:22Z",
      "released": "2021-12-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08018016M/1/SAS-Drive_Firmware_6421F_WN64_PT55_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6421F",
      "size": 10934392,
      "reboot_required": false,
      "description": "This release contains firmware version PT55 for supplier model number ST8000NM0185.",
      "revision_history": "Fixes:\n- Fix an issue that can make the drive unresponsive following a Hard Reset during writes.\n- Fix issues that can cause command timeout.\n- Fix issues that can cause Assert condition.\n- Fix an issue that can cause IOEDC error.\n\nEnhancements:\n- Improve performance for certain workloads.\n- Improve error logging / sense code reporting accuracy.\n- Improve SAS spec compliance."
    },
    {
      "id": "9f54d16b6a912067843cc2bd8568d7b9c3911cac62f7725298299613a5828fca",
      "name": "Seagate Lange Firmware Version EC16  for model number(s) XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "version": "EC16",
      "release_id": "H3VHX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-02-04T09:29:43Z",
      "released": "2021-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07035193M/1/SAS-Drive_Firmware_H3VHX_WN64_EC16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3VHX",
      "size": 10683112,
      "reboot_required": false,
      "description": "This release contains firmware version EC16 for Seagate drives. Vendor model numbers XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "revision_history": "Fixes:\n-Fix an issue where reading or writing of corrupt data can result after a power cycle\n-Fix an issue which can lead to reduced data retention duration\n-Fix an issue where assert can result when max. queue depth is exceeded\n-Update activity LED blinking behavior to be consistent with Dell requirements\n\nEnhancements:\n-N/A"
    },
    {
      "id": "5b978148232ea8a9cc141a5a3efc6c32234a86de2fa3c6b8717b390c9c06b127",
      "name": "HGST LT20  for model number(s) HGST HUH721008ALE600, HGST HUH721010ALE600.",
      "version": "LT20",
      "release_id": "65D08",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2020-12-07T05:47:11Z",
      "released": "2020-11-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06855978M/1/Serial-ATA_Firmware_65D08_WN64_LT20_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=65D08",
      "size": 11485312,
      "reboot_required": false,
      "description": "This release contains firmware version LT20  for HGST drives. Vendor model numbers HGST HUH721008ALE600, HGST HUH721010ALE600.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "8ceef66f6383dfe9b716f4c3f2b8518b194de729bd18cef56b63268e3e226b6f",
      "name": "HGST LS20 for model number(s) HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.",
      "version": "LS20",
      "release_id": "XYKWH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2020-11-18T05:01:14Z",
      "released": "2020-11-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06799321M/1/SAS-Drive_Firmware_XYKWH_WN64_LS20_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XYKWH",
      "size": 11457376,
      "reboot_required": false,
      "description": "This release contains firmware version LS20 for HGST drives. Vendor model numbers HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "b3bdd43b335a4c8a9d5e29d4e9b3c87f0b9b07ce533b4d1e7eeb0fe813120f70",
      "name": "Toshiba GB03 for MG07 ISE model number(s) MG07ACA14TEY and  MG07ACA12TEY",
      "version": "GB03",
      "release_id": "0942Y",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2020-06-23T06:41:48Z",
      "released": "2020-06-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06333095M/1/Serial-ATA_Firmware_0942Y_WN64_GB03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0942Y",
      "size": 10677472,
      "reboot_required": false,
      "description": "This release contains firmware version GB03 for Toshiba MG07 ISE drives - Vendor model number(s) MG07ACA12TEY and MG07ACA14TEY",
      "revision_history": "- Improved the performance for 100MB Random Read/Write.\n- Improved performance for ShortRange Access.\n- Improved performance for ShortRange Access.\n- Fixed the hang by read data xfer in the case of receiving COMRESET.\n- Fixed hang up issue if deep Read Retry occurs and then seek error occurs at the timing when corresponded retry sector is read.\n- Fixed the response of SECURITY ERASE UNIT in the case of following confition.The drive should execute SECURITY ERASE UNIT command only when SECURITY ERASE PREPARE command issues just before SECURITY ERASE UNIT command. If there is any other commands between SECURITY ERASE PREPARE command and SECURITY ERASE PREPARE command,the drive should issue abort. However drive responded normally at even this condition.\n- Improved recovery function when multiple intrenal log broken at power on.\n- Improved the intrenal log loading seqeunce at online FW download.\n- Fixed the internal log loading count at online FW download.\n- Supported for P11 temperature reporting features.\n- Fixed the hang by DownloadMicode CMD in the case of receiving COMRESET.\n- Fixed the issue of internal hang  when Security Erase Unit CMD was recieved from host by unAlign LBA.\n- Fixed the write data currupt when pre-read occurred error in non-Align Access.\n- Added Reverse sequential read Function.\n- Fixed the hang when UnCorrectable error occured at read data transfer.\n- Improved internal que latency at refresh write.\n- improved partial/slumber state time.\n- Changed attribute value ID=5,197 from 512byte unit to 4K byte unit.\n- Improved the performance for 2MB Random Read/Write Mix R70/W30.\n- Fixed the SCT Timeout issue caused by badly management of cache in the case of repetition write to same address.\n- Change interval time for DST to start from 0ms to 500ms.\n- Fixed the NCQ Command response at standby state."
    }
  ]
}
