  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "t140",
  "name": "T140",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge T140 Recommended Updates",
  "filter": "recommended",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 19,
      "rss": "/t140/urgent/rss.xml",
      "api": "/api/t140/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 61,
      "rss": "/t140/recommended/rss.xml",
      "api": "/api/t140/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 20,
      "rss": "/t140/optional/rss.xml",
      "api": "/api/t140/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/t140/bios/rss.xml",
      "api": "/api/t140/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/t140/chipset/rss.xml",
      "api": "/api/t140/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/t140/diagnostics/rss.xml",
      "api": "/api/t140/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/t140/drivers-for-os-deployment/rss.xml",
      "api": "/api/t140/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 6,
      "rss": "/t140/express-flash-pcie-ssd/rss.xml",
      "api": "/api/t140/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/t140/firmware/rss.xml",
      "api": "/api/t140/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/t140/idrac/rss.xml",
      "api": "/api/t140/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 15,
      "rss": "/t140/network/rss.xml",
      "api": "/api/t140/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 30,
      "rss": "/t140/sas-drive/rss.xml",
      "api": "/api/t140/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 5,
      "rss": "/t140/sas-non-raid/rss.xml",
      "api": "/api/t140/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 11,
      "rss": "/t140/sas-raid/rss.xml",
      "api": "/api/t140/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 22,
      "rss": "/t140/serial-ata/rss.xml",
      "api": "/api/t140/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/t140/systems-management/rss.xml",
      "api": "/api/t140/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/t140/video/rss.xml",
      "api": "/api/t140/video"
    }
  ],
  "count": 61,
  "updates": [
    {
      "id": "76245d0a584c5ccc82e289fc13f517d6fe16339b10aa85c49a062f45e8a4f53d",
      "name": "DELL System Update, v.2.3.0.2",
      "version": "2.3.0.2",
      "release_id": "RDVR3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-11-06T11:10:35Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213121M/1/Systems-Management_Application_RDVR3_WN64_2.3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RDVR3",
      "size": 30983200,
      "reboot_required": false,
      "description": "DELL System Update (DSU) is a software designed to facilitate the application of updates on various Dell systems. Using DSU you can:\n1.Identify the available updates, select the relevant updates, and deploy the updates on multiple systems.\n2.Maintain consistency in terms of interface and versions across Operating Systems, Repositories, and Systems.",
      "revision_history": "Enhancement :\n\nOS native support with passthrough and rsystemtype iDRAC \n\nFixes :\n\nSecurity Issues"
    },
    {
      "id": "fd473c28f7250f2c6d18913dc3111f4d695b92c719953f933d5de9f4f624cd1b",
      "name": "Dell PERC H330 Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "NYKX7",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:21:18Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07211734M/4/SAS-RAID_Firmware_NYKX7_WN64_25.5.9.0001_A15_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NYKX7",
      "size": 25051800,
      "reboot_required": true,
      "description": "Dell PERC H330 Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "5c912c46b71cf36439ff040f72dfd483a636caf6953566b7822e906ce3a8e030",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "version": "25.5.8.0001",
      "release_id": "WRF3Y",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:12:44Z",
      "released": "2020-09-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06547525M/4/SAS-RAID_Firmware_WRF3Y_WN64_25.5.8.0001_A16_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WRF3Y",
      "size": 25507720,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "revision_history": "Fixes:\n-Fixed an isolated issue where manually run controller self-diagnostics would trigger Event 13 (Controller cache discarded due to firmware version incompatibility) on the subsequent reboot.\n\nEnhancements:\n-Enhanced Background Initialization (BGI) and Consistency Check (CC) progress to reduce performance impact when progress is saved (checkpointed).\n  Previous behavior:\n    BGI/CC progress was saved to disk every 5 minutes, this disk access triggered I/O to pause and cache flush, causing a latency increase.\n   New behavior (as of 25.5.8.0001):\n    BGI/CC progress was saved to disk every 5 minutes if an operating system/driver is not loaded.\n          Note: H330 controllers will keep background operations paused while in HII, or until an OS is loaded.\n    When the firmware detects a driver loading, BGI/CC progress will be saved every 4 hours.\n    When a graceful shutdown is performed, the firmware will save progress as part of the shutdown procedure.\n    In the event of ungraceful shutdown/power loss progress will resume from the last saved checkpoint.\n          Note: Progress Events remain unchanged and will be observed at the same interval."
    },
    {
      "id": "493d6478a65cc15bfbb6c50488217952ef5f4c79a9bf9c593c18ece67ef5ed3e",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "700GG",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-05T16:45:15Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07217671M/3/SAS-RAID_Firmware_700GG_WN64_25.5.9.0001_A17_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=700GG",
      "size": 25505712,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "113d023faa13725bb8fbe0e0815d6451ee036b77483afd1f68ec9c85755126e9",
      "name": "Dell iDRAC Service Module Installer for OS DUP v5.4.2.0",
      "version": "5.4.2.0",
      "release_id": "WMJ1N",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-09-29T07:14:37Z",
      "released": "2025-10-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13800885M/4/Systems-Management_Application_WMJ1N_WN64_5.4.2.0_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WMJ1N",
      "size": 34063584,
      "reboot_required": false,
      "description": "iDRAC Service Module (iSM) is a lightweight software service that better integrates operating system (OS) features with iDRAC and can be installed on Dell’s yx5x or later generation of PowerEdge servers. iSM provides OS-related information to the iDRAC and adds capabilities such as LC log event replication into the OS log, WMI support (including storage), iDRAC SNMP alerts via OS, iDRAC hard reset and remote full Power Cycle. iSM automates SupportAssist report collection process for iDRAC leading to faster issue resolution. iSM has very little impact on the host processor and smaller memory footprint than \"in-band\" agents such as Dell EMC OpenManage Server Administrator (OMSA), thus expanding iDRAC management into supported host operating systems.",
      "revision_history": "Fixes:\n=====\nNA\nEnhancements:\n============\nEnabled SUSE LINUX ENTERPRISE SERVER 16"
    },
    {
      "id": "ddd0e2c51b4580eb2778870b68324d237a03ac014aa8e6f1d071efa03f75333c",
      "name": "BOSS-S2 Firmware",
      "version": "2.5.13.4009",
      "release_id": "TTR5R",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-25T07:01:26Z",
      "released": "2023-02-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09232098M/7/SAS-RAID_Firmware_TTR5R_WN64_2.5.13.4009_A01_06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TTR5R",
      "size": 22410088,
      "reboot_required": true,
      "description": "BOSS-S2 ROM version 2.5.13.4009",
      "revision_history": "Fixes:\n\n-- Addressed false M.2 failures reported due to thermal issues \n               \nEnhancements:\n-- Added new SDID 0x2261 on BOSS-S2 controller"
    },
    {
      "id": "1aa67fe97be9b69f74c41d082bf3193e5c0511a1cbaac86f436a4b56b04d5149",
      "name": "BOSS-S1 Adapter firmware",
      "version": "2.5.13.3024",
      "release_id": "3P39V",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-28T11:06:39Z",
      "released": "2020-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06189651M/8/SAS-RAID_Firmware_3P39V_WN64_2.5.13.3024_A07_07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3P39V",
      "size": 23542088,
      "reboot_required": true,
      "description": "BOSS-S1 Adapter ROM version 2.5.13.3024",
      "revision_history": "Fixes:YES\nFixed PPID Discrepancy for M.2 drives of BOSS controller in iDRAC Hardware inventory page\nFixed an issue to resolve the Offline Bundle installation of ESXi 6.x CLI via VUM\nFixed a behavior in firmware to handle when create \u0026 delete VD command execute in loop.\nEnhancements:YES\nNew unified BOSS Console/Management driver for all Windows operating systems."
    },
    {
      "id": "e030fecbf94eb9512ae1dfa4fb776046fd4612d06268cb14e6909c5d697489ae",
      "name": "BOSS-S1 Modular firmware",
      "version": "2.6.13.3025",
      "release_id": "F9F16",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-27T11:07:40Z",
      "released": "2023-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09214778M/11/SAS-RAID_Firmware_F9F16_WN64_2.6.13.3025_A08_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F9F16",
      "size": 23542872,
      "reboot_required": true,
      "description": "BOSS-S1 Modular ROM version 2.6.13.3025",
      "revision_history": "Fixes : HW Re-spin \nAddressed false M.2 failures reported due to thermal issues\n\nEnhancements : Added new SDID 0x2260 on BOSS-S1 controller"
    },
    {
      "id": "3735b6b54fcf04cd59cca7137654bb59c8fcdefecff53476ea296922b2fd6175",
      "name": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\nFW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.",
      "version": "PV10",
      "release_id": "8R6W6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-25T09:20:50Z",
      "released": "2025-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13676887M/1/Serial-ATA_Firmware_8R6W6_WN64_PV10_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8R6W6",
      "size": 23949896,
      "reboot_required": false,
      "description": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\n'FW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.\nIncludes FW update to add recognition of 2TB SATA capacity part number",
      "revision_history": "FW update to add Dell Part Number for newly added 2TB capacity"
    },
    {
      "id": "7de4851004c1bfeabb7fb64a8f7126fea032427318f4ed2b242114da8421a7be",
      "name": "Seagate CimarronBP SATA for FW LC0A for model numbers ST2000NM012B-2TD130, ST4000NM018B-2TF130",
      "version": "LC0A",
      "release_id": "T04YV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:22:43Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12638788M/2/Serial-ATA_Firmware_T04YV_WN64_LC0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T04YV",
      "size": 23567464,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SATA ISE 512n HDD.  Model numbers: ST2000NM012B-2TD130 and ST4000NM018B-2TF130\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for drive returning good status on a download that was interrupted with a link reset.\n- Fix for potential assert during IO test while looping writesame command."
    },
    {
      "id": "9d3a909718077b49b7c8c9902c53facf85f1cfdfc24edabfce073cd264cc800c",
      "name": "Hitachi PU09 for Vela-A ISE model number(s) HUS726T4TALS200",
      "version": "PU09",
      "release_id": "J5K8G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T11:03:41Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024400M/2/SAS-Drive_Firmware_J5K8G_WN64_PU09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J5K8G",
      "size": 24727008,
      "reboot_required": false,
      "description": "FW update for WDC Vela-A 512n SAS HDD, Model number HUS726T4TALS200.\n\n- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "9919a72526e3192f77c158c625e5ec4efa06638905b3c239de5820e669db369e",
      "name": "BOSS Console Management driver for WS2022-2025",
      "version": "1.2.0.1055",
      "release_id": "7004G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-12-18T11:18:14Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11846807M/2/SAS-RAID_Driver_7004G_WN64_1.2.0.1055_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7004G",
      "size": 12936864,
      "reboot_required": false,
      "description": "BOSS Console Management driver for WS2022-2025",
      "revision_history": "Fixes: None,\nEnhancements: Console Management Driver enablement for MS Windows 2025."
    },
    {
      "id": "c5d54c034608aea2b30ae772d2f1f626db4814ccac68e55449f6043dcf90ab77",
      "name": "HGST RT09 for Vela-AP SATA ISE model number(s) HUS728T8TALE6L0",
      "version": "RT09",
      "release_id": "T0RX4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T09:40:40Z",
      "released": "2024-04-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025871M/1/Serial-ATA_Firmware_T0RX4_WN64_RT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T0RX4",
      "size": 13355792,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SATA HDD, Model number HUS728T8TALE6L0.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "5dfbeeafb4ce29aa30f615ae567aeed3c55b796b2de7aba6cc45b2f12cceca39",
      "name": "Hitachi PT09 for Vela-A ISE model number(s) HUS726T4TALA6L0",
      "version": "PT09",
      "release_id": "CWPJH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T09:13:23Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025719M/1/Serial-ATA_Firmware_CWPJH_WN64_PT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CWPJH",
      "size": 13487376,
      "reboot_required": false,
      "description": "'FW update for WDC Vela-A 512e SATA HDD, Model number HUS726T6TALE6L0.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "3da2d1c93d40ba01200cdc48b85bb0f0a85dcb6e489b9eaa0d9d32bcbf861b9f",
      "name": "HGST PS09 for Vela-A ISE model number(s) HUS726T6TAL4200 and HUS726T6TAL5200",
      "version": "PS09",
      "release_id": "8MJFT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T07:20:39Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024641M/1/SAS-Drive_Firmware_8MJFT_WN64_PS09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8MJFT",
      "size": 13464192,
      "reboot_required": false,
      "description": "This release contains firmware version PS09 for HGST Vela-A ISE drives - Vendor model number(s) HUS726T6TAL4200 and HUS726T6TAL5200.\n'FW update for WDC Vela-A 512e SAS HDD, Model number HUS726T6TAL5200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "2e142fa2b3bba65e6701761803eb6b88963468bee9960a715304452f1a20de58",
      "name": "Intel NIC Family Version 23.0.0 Firmware for Intel I350 and X550 Adapters",
      "version": "23.0.8",
      "release_id": "WVM0R",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-08T02:04:05Z",
      "released": "2024-07-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890380M/3/Network_Firmware_WVM0R_WN64_23.0.8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WVM0R",
      "size": 13964792,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 23.0.X on Intel I350, I354 and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "Fixes\n=====\n   - Fixed problem where updating I350 NICs would not preserve the Virtualization Mode and would reset \n     the Virtualization Mode to the factory default of \"None\". {266366}\n   - Fixed an issue where Intel i350-based NICs would display invalid boot options in Boot Manager in the \n     legacy boot mode. {277961}\n     \nKnown Issues\n============\n   - Devices based on the Intel(R) Ethernet I350 controller do not support the LLDP Discovery feature\n     with Dell iDRAC.\n   - Received packets with incorrect length can generate alarms in VMware ESXi 7.0U2 and later.\n     These alarms can be ignored. Please reference this VMware KB article for more details: \n     https://kb.vmware.com/s/article/83627. {229496, 232005}"
    },
    {
      "id": "6dffa0fa05d98ecf5dd6f683737e3ab3d4e113f263fe4ec62004af5ecf3268e8",
      "name": "Intel NIC Family Version 23.0.0 Drivers for Windows 64-bit Operating Systems",
      "version": "23.0.0",
      "release_id": "6JHVK",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-07-19T15:27:45Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890492M/1/Network_Driver_6JHVK_WN64_23.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6JHVK",
      "size": 42776640,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "See readme.txt for more info."
    },
    {
      "id": "baa5cac92e3b072bd227668372c2c7520ed3e15c5a55003853c701aa0df1e8a2",
      "name": "HGST J17L for model number(s) HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "version": "J17L",
      "release_id": "0NKFF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-31T05:53:56Z",
      "released": "2024-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11625826M/3/SAS-Drive_Firmware_0NKFF_WN64_J17L_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0NKFF",
      "size": 12890680,
      "reboot_required": false,
      "description": "This release contains firmware version J17L for HGST drives. Vendor model numbers HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "revision_history": "External: FW update for HGST Bear Cove MLC 3WPD SAS HDD, Model numbers HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200, HUSMR3232ASS200.\nIncludes FW fix to free space buffer calculation to avoid a potential assert condition resulting in a self-initiated reset."
    },
    {
      "id": "457ece2bc644069fab86e59d8d629ce72abd2ea321c4374bec6ae5340321f69f",
      "name": "Samsung PM9A3 NVMe M.2 22x110 for FW 1.1.1 version for model numbers(s) MZ1L2960HCJR-00AD3, MZ1L21T9HCLS-00AD3.",
      "version": "1.1.1",
      "release_id": "HX5W6",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-20T10:56:05Z",
      "released": "2024-05-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11638925M/1/Express-Flash-PCIe-SSD_Firmware_HX5W6_WN64_1.1.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HX5W6",
      "size": 9471384,
      "reboot_required": false,
      "description": "Samsung PM9A3 NVMe M.2 22x110 for FW 1.1.1 version for model numbers(s) MZ1L2960HCJR-00AD3, MZ1L21T9HCLS-00AD3. \n\nThis update includes important reliability enhancements and also improves drive enumeration. Firmware version 1.1.1 for Samsung PM9A3 M.2 drives, models MZ1L21T9HCLS-00AD3 and MZ1L2960HCJR-00AD3.",
      "revision_history": "Disable (LTR( Latency Tolerance Reporting) to avoid delays on non-supported systems\n- Additional command syntax updates.\n- Add Log page C0 support"
    },
    {
      "id": "67853bdae5f8f83316b8093431448ef64ab284feb1b58cea3b0eaa7e3c004854",
      "name": "Toshiba GD05 for MG08 Air SATA 4TB program for model number(s) MG08ADA400NY.",
      "version": "GD05",
      "release_id": "F73C5",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-08T08:33:43Z",
      "released": "2024-01-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11347964M/1/Serial-ATA_Firmware_F73C5_WN64_GD05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F73C5",
      "size": 12767200,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba GD05 for MG08 Air SATA 4TB program for model number(s) MG08ADA400NY",
      "revision_history": "Fixes:\n'- Improves performance in ECS systems\n- Improves performance for random access workloads\n- Firmware addresses several corner case bugs in error handling scenarios\n- Firmware implements several internal process optimizations and enhancements"
    },
    {
      "id": "d86b90f28fe1d8aad0a35501f97aec38c1b7821eff4a67a08d7ebce6a14c831b",
      "name": "Samsung SM883 MU SSDR, FW  HF58. Vendor model numbers MZ7KH480HAHQ0D3, MZ7KH960HAJR0D3, MZ7KH1T9HAJR0D3, and MZ7KH3T8HALS0D3.",
      "version": "HF58",
      "release_id": "3J3JR",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-28T11:17:02Z",
      "released": "2021-04-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06950272M/3/Serial-ATA_Firmware_3J3JR_WN64_HF58_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3J3JR",
      "size": 13590256,
      "reboot_required": false,
      "description": "This release contains firmware version HF58 for vendor model numbers MZ7KH480HAHQ0D3, MZ7KH960HAJR0D3, MZ7KH1T9HAJR0D3, and MZ7KH3T8HALS0D3",
      "revision_history": "Fixes:-\n- Correct Log Addres 99h Vendor Name string from \"DELL\" to \"SAMSUNG\".\n- Disable RESTRICTED SANITIZE OVERRIDES SECURITY feature, per Dell spec.\n- Fix Pin 11 OOB Default Signal issue, where signal is returned \"High\" after repeated FW updates.\n- Other minor fixes as described in the FCN."
    },
    {
      "id": "54f45b3e3ed95a4734d61ae1b0410bd9bdf58b64e5d771908f77aaa00e5f2b20",
      "name": "Windows Server 2016 Driver 6.604.06.00 for PERC H330/H730/H730P/H830/H730P MX/FD33xD/FD33xS Controllers",
      "version": "6.604.06.00",
      "release_id": "T244W",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-02-19T07:08:49Z",
      "released": "2016-09-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER03940499M/11/SAS-RAID_Driver_T244W_WN64_6.604.06.00_A01_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T244W",
      "size": 6848432,
      "reboot_required": true,
      "description": "Windows Server 2016 Driver 6.604.06.00 for PERC H330/H730/H730P/H830/H730P MX/FD33xD/FD33xS Controllers",
      "revision_history": "Fixes\n- N/A\n\nEnhancements\n-  Added 1MB I/O support for H730, H730P and H830 controllers."
    },
    {
      "id": "0b31c8b898ed59bbe95d33ddc5569a0c7e8b081e311d48266f1880ad78149d26",
      "name": "Samsung PM883 RI SSDR, FW HE59 for model number(s) MZ7LH7T6HMLA0D3, MZ7LH240HAHQ0D3, MZ7LH3T8HMLT0D3, MZ7LH480HAHQ0D3, MZ7LH960HAJR0D3, MZ7LH1T9HMLT0D3",
      "version": "HE59",
      "release_id": "93P7P",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T14:10:28Z",
      "released": "2021-04-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06949454M/3/Serial-ATA_Firmware_93P7P_WN64_HE59_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=93P7P",
      "size": 13454032,
      "reboot_required": false,
      "description": "This release contains firmware version HE59 for Samsung PM883 RI SSDR,  for model number(s) MZ7LH7T6HMLA0D3, MZ7LH240HAHQ0D3, MZ7LH3T8HMLT0D3, MZ7LH480HAHQ0D3, MZ7LH960HAJR0D3, MZ7LH1T9HMLT0D3",
      "revision_history": "Fixes:-\n- Correct Log Addres 99h Vendor Name string from \"DELL\" to \"SAMSUNG\".\n- Disable RESTRICTED SANITIZE OVERRIDES SECURITY feature, per Dell spec.\n- Fix Pin 11 OOB Default Signal issue, where signal is returned \"High\" after repeated FW updates.\n- Other minor fixes as described in the FCN.\nEnhancements:\n-N/A"
    },
    {
      "id": "b555e039474597e95f58335c912d0276633df1089499675842744e0e344b31eb",
      "name": "MICRON 5200 RI/ MU  SATA \u0026apos;F005\u0026apos; FW for model number(s) MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, MTFDDAK1T9TDN, MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD.",
      "version": "F005",
      "release_id": "W2X8N",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T09:43:52Z",
      "released": "2022-04-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11196038M/1/Serial-ATA_Firmware_W2X8N_WN64_F005_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=W2X8N",
      "size": 12468256,
      "reboot_required": false,
      "description": "This release contains Micron firmware F005 for models MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD, MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, and MTFDDAK1T9TDN for all operating systems.",
      "revision_history": "Fixes:\n-F004 FW had a corner case failure mode when a read command is sent followed by large write command.  The internal logic to manage command priority had a bug causing the drive to issue a com-reset.  In F005 this logic was corrected and the internal logic for managing command priority was working as expected.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "c0c35ec567586d3e598e838a175f119121b72445109dbe8bf5b5795acfdf074a",
      "name": "Intel DL6R  for model number(s) SSDSCKKB240G8R, SSDSCKKB480G8R, SSDSCKKB960G8R.",
      "version": "DL6R",
      "release_id": "Y1P10",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T09:29:44Z",
      "released": "2020-09-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06303847M/2/Serial-ATA_Firmware_Y1P10_WN64_DL6R_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=Y1P10",
      "size": 12056704,
      "reboot_required": false,
      "description": "This release contains firmware version DL6R for Intel drives. Vendor model numbers  SSDSCKKB240G8R, SSDSCKKB480G8R, SSDSCKKB960G8R.",
      "revision_history": "Fixes:\n-SMART attribute shift solution\n-MRR settings to mitigate BJ004 issue\n-Fixes an issue where drive stops responding after soft-reboot following windows install\n\nEnhancements:\nN/A"
    },
    {
      "id": "a8b1e0ff70577053055c81ba5d89b33b230c806ff7acb209674a38825b77cb5e",
      "name": "Windows Server 2019 Driver version 2.51.25.02  for Dell 12Gbps HBA and HBA330",
      "version": "2.51.25.02",
      "release_id": "MF8G0",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-01-24T22:33:31Z",
      "released": "2019-02-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05448721M/8/SAS-Non-RAID_Driver_MF8G0_WN64_2.51.25.02_A00_07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MF8G0",
      "size": 6134720,
      "reboot_required": true,
      "description": "Windows Server 2019 Driver version 2.51.25.02 for Dell 12Gbps HBA and HBA330",
      "revision_history": "Fixes:\nN/A\n\nEnhancements:\nWindows Server 2019 SDDC Certification\nImproved behavior to correctly display the number of drives after installing downstream backplanes (Mid / Rear Backplane)."
    },
    {
      "id": "b601ecce804aadbaa077403eef3e0423412e341361f6a509c27d184516de9a35",
      "name": "HGST LT21  for model number(s) HGST HUH721008ALE600, HGST HUH721010ALE600.",
      "version": "LT21",
      "release_id": "H12N2",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T17:46:19Z",
      "released": "2021-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07861656M/2/Serial-ATA_Firmware_H12N2_WN64_LT21_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H12N2",
      "size": 12987416,
      "reboot_required": false,
      "description": "This release contains firmware version LT21  for HGST drives. Vendor model numbers HGST HUH721008ALE600, HGST HUH721010ALE600.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "61edd309f7f5b8a0379422e8f130a8a435c50d219bf19779761e531913b587b5",
      "name": "Seagate DB34 for model number(s) ST4000NM0265-2DC107, ST2000NM0145-2DC104 and ST1000NM0095-2DC10C.",
      "version": "DB34",
      "release_id": "M5GJ1",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T16:20:40Z",
      "released": "2017-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04310774M/2/Serial-ATA_Firmware_M5GJ1_WN64_DB34_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M5GJ1",
      "size": 11438848,
      "reboot_required": false,
      "description": "This release contains firmware version DB34 for Seagate drives. Vendor model numbers ST4000NM0265-2DC107, ST2000NM0145-2DC104 and ST1000NM0095-2DC10C.",
      "revision_history": "Fixes:\n-Fix an issue where timeout can result by serial port noise\n-Fix issues where assert condition can result\n-Fix an issue where IOEDC error can result\n-Fix an issue where hang event can result\n-Fix issues related to DST funcitonality\n\nEnhancements:\n-Improve status reporting/logging accuracy"
    },
    {
      "id": "0f2aad04e3d715fe60af5cb8dca609f6a76e3d07ca5f0ab96be68d1f12b515a0",
      "name": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "version": "B326",
      "release_id": "7FV43",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T11:30:04Z",
      "released": "2024-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11166204M/1/SAS-Drive_Firmware_7FV43_WN64_B326_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7FV43",
      "size": 12699824,
      "reboot_required": false,
      "description": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "revision_history": "Fixes: \n\nFix1:  \n- When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  Fixed FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.\n                                                                                                                                                                                   \nFix 2: \n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\n\nFix 3: \n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "af718bba045a1770880a3798635bd2970568b875f053f212b6a59895db94ec42",
      "name": "HGST MU03 for model number(s) HUS722T2TALA600 and HUS722T1TALA600.",
      "version": "MU03",
      "release_id": "V3DJM",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:51:43Z",
      "released": "2018-08-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05040482M/6/Serial-ATA_Firmware_V3DJM_WN64_MU03_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3DJM",
      "size": 12145288,
      "reboot_required": false,
      "description": "This release contains firmware version MU03 for HGST drives. Vendor model numbers HUS722T2TALA600 and HUS722T1TALA600.",
      "revision_history": "Fixes\n- Fix for an possible interrupt during Dell factory process during repeated I/O commands.\n\nEnhancements\nn/a"
    },
    {
      "id": "fac9a96d3131d0683ff088b6b7c569bcedb7ed1b44313e780ea02cedbb46fd62",
      "name": "Seagate EA04 for model number(s) ST2000NM0018-2F3130 and ST1000NM0018-2F2130.",
      "version": "EA04",
      "release_id": "CMK5N",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:45:56Z",
      "released": "2017-05-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04268619M/2/Serial-ATA_Firmware_CMK5N_WN64_EA04_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CMK5N",
      "size": 10708496,
      "reboot_required": false,
      "description": "This release contains firmware version EA04 for Seagate drives. Vendor model numbers ST2000NM0018-2F3130 and ST1000NM0018-2F2130.",
      "revision_history": "Initial Release"
    },
    {
      "id": "261ba63129d1f41b2914071e82cd4a6a82940967e80d3d8e61f5f08155c4a3a8",
      "name": "HGST LS21 for model number(s) HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.",
      "version": "LS21",
      "release_id": "MGW91",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:28Z",
      "released": "2021-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07861414M/2/SAS-Drive_Firmware_MGW91_WN64_LS21_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MGW91",
      "size": 12336240,
      "reboot_required": false,
      "description": "This release contains firmware version LS21 for HGST drives. Vendor model numbers HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "7befc05c945f5c3f654ebd22984277341f826f5c59d0f9290977ad0b4488cfa7",
      "name": "Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "version": "EK06",
      "release_id": "GTG81",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-17T06:10:13Z",
      "released": "2024-01-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11140543M/1/SAS-Drive_Firmware_GTG81_WN64_EK06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GTG81",
      "size": 12131264,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "revision_history": "Fixes:\n- Addresses an issue that could cause occasional read errors"
    },
    {
      "id": "8d33fbc9505faadcdc82ee99539697362e5f79fc290474a679ca2d620cbd3500",
      "name": "Seagate SBT5 for Skybolt ServoBP program for model number(s) CL2400MM0149.",
      "version": "SBT5",
      "release_id": "0128H",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:51:08Z",
      "released": "2023-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10019191M/2/SAS-Drive_Firmware_0128H_WN64_SBT5_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0128H",
      "size": 12817600,
      "reboot_required": false,
      "description": "This release contains firmware version SBT5  for Seagate Skybolt ServoBP program for model number(s) CL2400MM0149",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled."
    },
    {
      "id": "51252624b4929e0e9c705e59c55fca91ae5867bfb2b5bb21680df2b58fd499d0",
      "name": "Windows Server 2019 Driver 2.61.48.00 for HBA10-11 Controllers",
      "version": "2.61.48.00",
      "release_id": "WFV95",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-01-05T04:18:59Z",
      "released": "2023-03-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09649518M/2/SAS-Non-RAID_Driver_WFV95_WN64_2.61.48.00_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WFV95",
      "size": 6524184,
      "reboot_required": true,
      "description": "This release updates Windows 2019 Server driver to 2.61.48.00 for HBA345 Adapter/Front, HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter/MX/MM/MMLP Controllers.",
      "revision_history": "N/A"
    },
    {
      "id": "d8437b996ac697e05d66eea0c991e755d0142e2a4dbf3d2ad3bd95a4feb929d3",
      "name": "Intel NIC Family Version 22.0.0 Drivers for Windows Server 2019 and 2022 Operating Systems",
      "version": "22.0.0",
      "release_id": "X9PPT",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-13T18:44:32Z",
      "released": "2023-03-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09683951M/2/Network_Driver_X9PPT_WN64_22.0.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9PPT",
      "size": 44210816,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "Fixes\n=====\n- Resolved an issue where ETrackID, NVM Version, and FW Version field information was missing\n  in ProSet for X710, XL710, and XXV710 adapters. {242553}\n- Resolved an issue where on Windows Server OSs with Intel(R) Ethernet 25G 2P E810-XXV-k Mezz\n  adapters, hardware diagnostic tests using PROSet ACU would cause errors. {240055}\n\nEnhancements\n=====\n- Introduces performance counters manifest file for Intel (R) E810 devices, which can be imported into the \n  Microsoft Windows utility PerfMon. {D3752}"
    },
    {
      "id": "fe3df57f88a24821dcfe6da938dea1cb5969fd93d89df900376eb41cf1b3ac98",
      "name": "Intel NIC Family Version 22.5.0 Firmware for I350, I354, and X550 Adapters",
      "version": "22.5.7",
      "release_id": "TNXW1",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T20:37:20Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646092M/2/Network_Firmware_TNXW1_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TNXW1",
      "size": 16735312,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "d3eed91a60fa56f5c019a5054397909a6048bc64dd5e68a6554bf7f7f7b8b5de",
      "name": "This release contains firmware version CSNE for STX drives. Vendor model numbers ST8000NM015A.",
      "version": "CSNE",
      "release_id": "YRJ44",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-06T14:30:56Z",
      "released": "2023-09-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10568714M/1/SAS-Drive_Firmware_YRJ44_WN64_CSNE_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YRJ44",
      "size": 12803248,
      "reboot_required": false,
      "description": "This release contains firmware version CSNE for STX drives. Vendor model numbers ST8000NM015A.",
      "revision_history": "Fixes:\n- Fix for potential drive assert during read on arrival.\n- Fix for drive hang after power cycle during cross-download testing."
    },
    {
      "id": "7f3c1816a8abb0d5de05c5772def174d0e1ae5f6c9c2ad5523fd664903346ed8",
      "name": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "version": "CSJA",
      "release_id": "J12RT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-06-30T05:01:47Z",
      "released": "2023-06-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10268173M/1/SAS-Drive_Firmware_J12RT_WN64_CSJA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J12RT",
      "size": 12687840,
      "reboot_required": false,
      "description": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSJ8."
    },
    {
      "id": "f84b013e9621ed31205684b25a2ba7f1dbd31a1a6db20843fed82095972dc69a",
      "name": "Intel C240 Series Chipset Device Software(10.1.19283.8349)",
      "version": "10.1.19283.8349",
      "release_id": "K26V6",
      "category": "Chipset",
      "category_slug": "chipset",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2022-11-30T20:36:00Z",
      "released": "2022-11-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09145330M/2/Chipset_Driver_K26V6_WN64_10.1.19283.8349_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K26V6",
      "size": 8730656,
      "reboot_required": true,
      "description": "This release provides the driver for the Intel C240 Series Chipset and is supported on 14G PowerEdge R240/R340/T140/T340 systems running Windows Server 2022.",
      "revision_history": "Fixes:\n-NA\n\nEnhancements:\n- New driver from Intel for Mehlow"
    },
    {
      "id": "48fc6769c3d54386e4ab4b5c8a174f54b6143834b0cce7bd522820544b4c85a0",
      "name": "This release contains firmware version CSDA for STX drives. Vendor model numbers ST4000NM015A.",
      "version": "CSDA",
      "release_id": "59M5K",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-04-28T09:34:25Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486319M/1/SAS-Drive_Firmware_59M5K_WN64_CSDA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=59M5K",
      "size": 12285536,
      "reboot_required": false,
      "description": "This release contains firmware version CSDA for STX drives. Vendor model numbers ST4000NM015A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSD8.\n\nEnhancements:\nFixes and enhancement included are identical to those of CSD8."
    },
    {
      "id": "afad81c11ff922969d371d0fc4f99acfa5bc2d5a7b4cd74e2d2c1481ff5f57eb",
      "name": "Seagate KT5C for model number(s) DL900MP0136.",
      "version": "KT5C",
      "release_id": "83FF4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-08-27T08:44:48Z",
      "released": "2021-08-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07688573M/1/SAS-Drive_Firmware_83FF4_WN64_KT5C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=83FF4",
      "size": 11012312,
      "reboot_required": false,
      "description": "This release contains firmware version KT5C for Seagate drives. Vendor model numbers DL900MP0136.",
      "revision_history": "Fixes:\nFix an issue where single SAS port becomes unresponsive\nFix issues that can cause unwarranted SMART warning\nFix issues where assert can result\nFix issues where drive hang condition can result\nFix issues where command timeout can result\nEnhancements:\nImprove performance for certain workloads\nEnhance error logging / sense code reporting accuracy"
    },
    {
      "id": "edef243d8108958192caa385e61442f4dfeee160057a70aae31d7de1ea520510",
      "name": "Seagate KT7B for model number(s) ST900MP0136..",
      "version": "KT7B",
      "release_id": "0V8XY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-08-27T08:28:32Z",
      "released": "2021-08-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07688491M/1/SAS-Drive_Firmware_0V8XY_WN64_KT7B_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0V8XY",
      "size": 11012712,
      "reboot_required": false,
      "description": "This release contains firmware version KT7B for Seagate drives. Vendor model numbers ST900MP0136..",
      "revision_history": "Fixes:\nFix an issue where single SAS port becomes unresponsive\nFix issues that can cause unwarranted SMART warning\nFix issues where assert can result\nFix issues where drive hang condition can result\nFix issues where command timeout can result\nEnhancements:\nImprove performance for certain workloads\nEnhance error logging / sense code reporting accuracy"
    },
    {
      "id": "80318ba926a22165790009e8aa0a953888eeddac60c085b60146da569d6c5aa9",
      "name": "Intel NIC Family Version 20.5.0 Ethernet Driver",
      "version": "20.5.0",
      "release_id": "2YNFG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2021-07-08T17:20:16Z",
      "released": "2021-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07537990M/1/Network_Driver_2YNFG_WN64_20.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2YNFG",
      "size": 43279168,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update. Please extract the release note \"release.txt\" to find the supported adapters by this software bundle.",
      "revision_history": "Fixes and Enhancements are located in the associated \"release.txt\" file."
    },
    {
      "id": "048766de7693698178a808fce6d3c552a844ef53f883ca214c7b4aa694bacf92",
      "name": "OS COLLECTOR, v6.0",
      "version": "6.0",
      "release_id": "0G1JH",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2020-12-15T14:24:17Z",
      "released": "2020-12-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06878175M/2/Diagnostics_Application_0G1JH_WN64_6.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0G1JH",
      "size": 40064016,
      "reboot_required": false,
      "description": "OS COLLECTOR  6.0 is an integral component of the PowerEdge Embedded SupportAssist solution. OS COLLECTOR 6.0 is designed to supplement the iDRAC hardware state and configuration data with the host's operating system state \u0026 configuration information data as well as the system event logs. The purpose of Embedded SupportAssist is to enable serviceability on the box without the need to install or configure additional software on the customers' host. Embedded SupportAssist is available on the box, the day of RTS without enablement from the serviceability tools.",
      "revision_history": "Fixes:NA\nEnhancements:NA"
    },
    {
      "id": "b0982adc7c4c0f8266dc8f0568692e5a400f3ba3a83afc512ca5ef83dbd78cf5",
      "name": "Toshiba GA09 for model number(s) MG06ACA10TEY, MG06ACA800EY and MG06ACA600EY.",
      "version": "GA09",
      "release_id": "PT7D8",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-12-11T14:43:20Z",
      "released": "2020-12-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06874149M/1/Serial-ATA_Firmware_PT7D8_WN64_GA09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PT7D8",
      "size": 10709208,
      "reboot_required": false,
      "description": "This package contains firmware version GA09 for Toshiba drives (vendor model numbers MG06ACA10TEY, MG06ACA800EY and MG06ACA600EY).",
      "revision_history": "-Applied the feature of reverse sequential read.\n-Improved performance for 2MiB random read random write and mixed read 70 percentage write 30 percentage\n-Changed aging time from 900ms to 1900ms the value is same as  in order to improve random access performance.\n-Improved algorithms of cache preservation."
    },
    {
      "id": "65645d5857702dfa62b35234f1f242791911d0ebba5aa55060456d258e81d3bb",
      "name": "Toshiba FK5D for model number(s) TOSHIBA MG04ACA100NY, TOSHIBA MG04ACA200NY and TOSHIBA MG04ACA400NY.",
      "version": "FK5D",
      "release_id": "V47C4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-07-14T07:08:33Z",
      "released": "2020-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06400316M/1/Serial-ATA_Firmware_V47C4_WN64_FK5D_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V47C4",
      "size": 10624128,
      "reboot_required": false,
      "description": "This release contains firmware version FK5D for Toshiba drives. Vendor model numbers TOSHIBA MG04ACA100NY, TOSHIBA MG04ACA200NY and TOSHIBA MG04ACA400NY.",
      "revision_history": "Fixes:\nSeek algorithm adjusted to reduces spikes in acoustic levels leading to audible noise concerns.\nDEFT algorithm modified to ensure drives with modified seek algorithm will still pass DEFT testing.\n\nEnhancements:\nN/A"
    },
    {
      "id": "d79e2b69cd2a5d02a58c27e0a5d7a5446cac3baf930e4d19fc54589ee4e3a887",
      "name": "Intel Youngsville refresh DL69 for model number(s). SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R",
      "version": "DL69",
      "release_id": "2674V",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-07-10T12:54:41Z",
      "released": "2020-04-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06387659M/1/Serial-ATA_Firmware_2674V_WN64_DL69_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2674V",
      "size": 10720968,
      "reboot_required": false,
      "description": "This release contains firmware version DL69 for Intel drives. Vendor model numbers  SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R.",
      "revision_history": "Fixes:\n-SMART attribute shift solution\n-MRR settings to mitigate BJ004 issue\n-Fixes an issue where drive stops responding after soft-reboot following windows install\n\nEnhancements:\nN/A"
    },
    {
      "id": "aa21bafc81cea64e80e431bf2d1e8530104677e6fd1258c71103fa959e41c19e",
      "name": "Seagate TT56 for model number(s) ST10000NM0256.",
      "version": "TT56",
      "release_id": "CD2WP",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-12-17T09:57:44Z",
      "released": "2019-12-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06001086M/1/SAS-Drive_Firmware_CD2WP_WN64_TT56_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CD2WP",
      "size": 10932728,
      "reboot_required": false,
      "description": "This release contains firmware version TT56 for Seagate Tatsu drives - Vendor model number ST10000NM0256.",
      "revision_history": "Fixes: \n-Fix issues where command timeout can result\n-Fix an issue where assert condition can result\n-Fix minor bugs\n\nEnhancements:\n-Improve performance for specific workloads\n-Improve interface protocol compliance"
    },
    {
      "id": "58ae83486fd525a6d7fc92aba56631b2227f7de7e3c671e4c14af15dbbc4d976",
      "name": "Intel NIC Family Version 19.5.0 Firmware for I350, I354, X520, X540, and X550 adapters",
      "version": "19.5.12",
      "release_id": "40NTK",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-12-09T20:56:33Z",
      "released": "2019-12-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05982935M/1/Network_Firmware_40NTK_WN64_19.5.12_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=40NTK",
      "size": 15755136,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Family Version 19.5.x on Intel I350, I354, X520, X540, and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "8b261aa1080cecb64c8ca48e687208602108b4d5ae173c8fa46965296fc0a633",
      "name": "Matrox Video Driver",
      "version": "4.4.0.4",
      "release_id": "N1HM4",
      "category": "Video",
      "category_slug": "video",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2019-10-22T05:43:09Z",
      "released": "2018-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05278833M/5/Video_Driver_N1HM4_WN64_4.4.0.4_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N1HM4",
      "size": 6189248,
      "reboot_required": true,
      "description": "This package contains the Matrox Video driver. A graphics or video driver is the software that enables communication between the graphics card and the operating system, games, and applications.",
      "revision_history": "Initial Release"
    },
    {
      "id": "d70e124fd5eb47e2c840087efbaab515361bdd2d7a22418a95246960b9800a43",
      "name": "Samsung DSL8 for model number(s) MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "version": "DSL8",
      "release_id": "PN27G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T20:14:23Z",
      "released": "2018-05-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04994832M/2/SAS-Drive_Firmware_PN27G_WN64_DSL8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PN27G",
      "size": 10407664,
      "reboot_required": false,
      "description": "This release contains firmware version DSL8 for Samsung drives. Vendor model numbers MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "revision_history": "Fixes\n-n/a\n\nEnhancements\n-n/a"
    },
    {
      "id": "c167a624468a834e419f2e7acf82c5cc2654cbe751c39da1c3c9ecfb54e0cfaa",
      "name": "Seagate NT72 for model number(s) ST2000NX0373.",
      "version": "NT72",
      "release_id": "WN08D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T19:37:16Z",
      "released": "2018-12-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05384185M/4/SAS-Drive_Firmware_WN08D_WN64_NT72_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WN08D",
      "size": 10530576,
      "reboot_required": false,
      "description": "This release contains firmware version NT72 for SUPPLIER model number(s) ST2000NX0373  Capacity of 2TB.",
      "revision_history": "fixes:\n-improve compatibility with Linux OS after Sanitize Cryptographic Erase was performed\n-Fix issues where Command Timeout can result\n-Fix issues where Assert can result\n-Fix an issue where drive hang can result\n-Fix an issue where Current Mode Page values revert to Default values after power cycle\n\nenhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "cf04369966eaf08ab986b13a85a2a7f2d0e058daf148bc011cde7d720abc1576",
      "name": "Seagate DSF3 for model number(s) ST4000NM0135..",
      "version": "DSF3",
      "release_id": "5M6GD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-07-26T06:17:17Z",
      "released": "2019-07-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05754416M/1/SAS-Drive_Firmware_5M6GD_WN64_DSF3_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5M6GD",
      "size": 10777472,
      "reboot_required": false,
      "description": "This release contains firmware version DSF2 for Seagate drives. Vendor model numbers ST4000NM0135..",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Fix issue where current Mode Page values reverted to Default values after Power Cycle\n-Fix issue where drive reports false tag overlap error 0B/4E/00\n-Fix issues where command timeout can result\n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "f19d623d58cb895d7e732c106ae92206f7be233121ece9c89dedba6cc95d576d",
      "name": "Seagate DT32 for model number(s) ST4000NM0295, ST2000NM0155 and ST1000NM0085.",
      "version": "DT32",
      "release_id": "3CRY1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-02-15T06:34:06Z",
      "released": "2019-01-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05461185M/1/SAS-Drive_Firmware_3CRY1_WN64_DT32_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3CRY1",
      "size": 10756320,
      "reboot_required": false,
      "description": "This release contains firmware version DT31 for Seagate drives. Vendor model numbers ST4000NM0295, ST2000NM0155 and ST1000NM0085.",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Fix issue where current Mode Page values reverted to Default values after Power Cycle    \n-Fix issue where drive reports false tag overlap error 0B/4E/00\n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\n-Fix issues where command timeout can result\n\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "06e6fa1d3e0650bdf356b4d03849c30c13263e8e3565403075dfdeb7a65f1a3e",
      "name": "Seagate BS05 for HDD ON 2.5 SAS12 15K 512e drive model number ST600MM0238 and ST300MM0078.",
      "version": "BS05",
      "release_id": "2R4CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-02-15T05:59:39Z",
      "released": "2019-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05461025M/1/SAS-Drive_Firmware_2R4CX_WN64_BS05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2R4CX",
      "size": 10737736,
      "reboot_required": false,
      "description": "This release contains firmware version BS05 for Seagate HDD Thunderbug 2.5 SAS12 10K 512n drive. Vendor model numbers: ST600MM0238 and ST300MM0078",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Current Mode Page values reverted to Default values after Power Cycle     \n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\n-Fix issues where command timeout can result\n-Fix issues where IOEDC error can result\n\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "10491b1c00614db7fd96d7c1826dad32e8959d9543522c1cd493d78408ab81f1",
      "name": "This release contains firmware version DS44 for Seagate drives. Vendor model numbers ST6000NM0105.",
      "version": "DS44",
      "release_id": "N04WN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-02-15T03:16:34Z",
      "released": "2019-02-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05460604M/1/SAS-Drive_Firmware_N04WN_WN64_DS44_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N04WN",
      "size": 10822936,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also reduces occasional long command completion latency. This release contains firmware version DS44 for Seagate drives. Vendor model numbers ST6000NM0105..",
      "revision_history": "Fixes:\n-none\n\nEnhancements:\n-Enabled firmware download by Microsoft Windows Server OS"
    },
    {
      "id": "e21d22a03055226af0ba080ecee384a30f94389ca4fa174eae3d7898277fcb87",
      "name": "Intel DL43 for model number(s) SSDSC2BB120G7R, SSDSC2BB150G7R, SSDSC2BB240G7R, SSDSC2BB480G7R, SSDSC2BB800G7R, SSDSC2BB960G7R, SSDSC2BB012T7R, SSDSC2BB016T7R, SSDSCKJB120G7R, SSDSCKJB150G7R, SSDSCKJB240G7R, SSDSCKJB480G7R, SSDSCKJB760G7R and SSDSCKJB960G7R.",
      "version": "DL43",
      "release_id": "CHJGV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T07:56:34Z",
      "released": "2017-10-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04614468M/2/Serial-ATA_Firmware_CHJGV_WN64_DL43_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CHJGV",
      "size": 10183056,
      "reboot_required": false,
      "description": "This release contains firmware version DL43 for Intel drives. Vendor model numbers SSDSC2BB120G7R, SSDSC2BB150G7R, SSDSC2BB240G7R, SSDSC2BB480G7R, SSDSC2BB800G7R, SSDSC2BB960G7R, SSDSC2BB012T7R, SSDSC2BB016T7R, SSDSCKJB120G7R, SSDSCKJB150G7R, SSDSCKJB240G7R, SSDSCKJB480G7R, SSDSCKJB760G7R and SSDSCKJB960G7R.",
      "revision_history": "Fixes:\n-Numerous minor bug fixes\n-DUP package fixes Linux error when executing DUP package\n-Fix for some M.2 drives not upgrading\n\nEnhancements:\n-Added support for Instant Scramble Erase commands"
    },
    {
      "id": "04ec308a99971de5cff5f462337b720c363907e5555189bb9cfd4a864710fd66",
      "name": "Seagate NSF2 for model number(s) ST2000NX0453..",
      "version": "NSF2",
      "release_id": "1HWVN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-21T08:24:58Z",
      "released": "2019-01-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05424349M/1/SAS-Drive_Firmware_1HWVN_WN64_NSF2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1HWVN",
      "size": 10649408,
      "reboot_required": false,
      "description": "This release contains firmware version NSF2 for Seagate drives. Vendor model numbers ST2000NX0453..",
      "revision_history": "Fixes\n-improve compatibility with Linux OS after Sanitize Cryptographic Erase was performed\n-Fix issues where Command Timeout can result\n-Fix issues where Assert can result\n-Fix an issue where drive hang can result\n-Fix an issue where IOEDC error can result\n-Fix an issue where Current Mode Page values revert to Default values after power cycle\n\nEnhancements\n-Improve performance for specific workload cases\n-Improve status/reporting accuracy"
    }
  ]
}