  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r9825",
  "name": "R9825",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R9825 Express Flash PCIe SSD Updates",
  "filter": "express-flash-pcie-ssd",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 1,
      "rss": "/r9825/urgent/rss.xml",
      "api": "/api/r9825/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 19,
      "rss": "/r9825/recommended/rss.xml",
      "api": "/api/r9825/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 20,
      "rss": "/r9825/optional/rss.xml",
      "api": "/api/r9825/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r9825/bios/rss.xml",
      "api": "/api/r9825/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r9825/boss/rss.xml",
      "api": "/api/r9825/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r9825/chipset/rss.xml",
      "api": "/api/r9825/chipset"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r9825/drivers-for-os-deployment/rss.xml",
      "api": "/api/r9825/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 13,
      "rss": "/r9825/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r9825/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 4,
      "rss": "/r9825/fibre-channel/rss.xml",
      "api": "/api/r9825/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/r9825/firmware/rss.xml",
      "api": "/api/r9825/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r9825/idrac/rss.xml",
      "api": "/api/r9825/idrac"
    },
    {
      "slug": "memory",
      "label": "Memory",
      "count": 1,
      "rss": "/r9825/memory/rss.xml",
      "api": "/api/r9825/memory"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 12,
      "rss": "/r9825/network/rss.xml",
      "api": "/api/r9825/network"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 3,
      "rss": "/r9825/sas-raid/rss.xml",
      "api": "/api/r9825/sas-raid"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 1,
      "rss": "/r9825/systems-management/rss.xml",
      "api": "/api/r9825/systems-management"
    }
  ],
  "count": 13,
  "updates": [
    {
      "id": "ccfd97107a9e25cbcb63ee627c90e940b3e098b5ead03496e601bf10d5e1ba88",
      "name": "Dell Express Flash NVMe PCIe SSD 6550 E3.S ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "P9DGW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-29T13:23:21Z",
      "released": "2025-06-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13313249M/2/Express-Flash-PCIe-SSD_Firmware_P9DGW_WN64_1.0.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P9DGW",
      "size": 34411896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 6550 E3.S ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any RHEL and Ubuntu OS. Either use Windows SLES or iDRAC for FW update - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "2784cac0b8b58ea70ad630208898d6eb97e9b03ca201d3538f7cdf540045f1b2",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N",
      "version": "1.3.1",
      "release_id": "VMDWF",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:48Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652186M/3/Express-Flash-PCIe-SSD_Firmware_VMDWF_WN64_1.3.1_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VMDWF",
      "size": 28699000,
      "reboot_required": true,
      "description": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N.",
      "revision_history": "Fixes: \n\nFW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "1946160ed0d0cb3359a20dfca14e8078ecac5f014fd8979c0efcaa3a71e82245",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "version": "1.1.0",
      "release_id": "4WN4V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-23T16:20:58Z",
      "released": "2026-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14428501M/2/Express-Flash-PCIe-SSD_Firmware_4WN4V_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4WN4V",
      "size": 34529136,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n1. Modified the FW to track second level read recovery triggers.\n2. Developed a firmware fix to add separate queues in the CPU coupled memory to monitor and control the flow of push \u0026 pop entries in the linked list to eliminate any possibility of unexpected concurrent accesses. A dedicated CPU is used for this solution to minimize performance impact.\n3. Modified the FW to set the pointer value to the designated structured memory area.\n4. Updated the firmware to optimize internal operations under this back-to-back power cycle scenario to properly manage APL interrupt.\n5. Updated the firmware to check the thermal throttling stage and manage the resource allocation appropriately before the initiating APL handling.\n6. Enhanced the firmware to handle the back-to-back PERST# operations to ensure that no transitions are missed.\n7. Updated the firmware to increase the PCIe bridge timeout to 1ms\n\nEnhancements:  \n1. Updated the FW to increase the CAP.TO value to 30 seconds for 9550 product family\n2. Updated the Firmware to correct the eye measurement algorithm to appropriately handle PCIe errors conditions.\n3. Enhanced the firmware to optimize folding operations under these specific workloads to improve performance consistency.\n4. Updated the firmware to keep the activity LED on when the host disables the controller (CC.EN=0)"
    },
    {
      "id": "fcaa808d62c877106d9e10016f37065f99096929161fea64791ad02e599e67f9",
      "name": "Dell Express Flash NVMe PCIe SSD LC9 E3.S ISE Firmware Release",
      "version": "1.0.4",
      "release_id": "JDM72",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-14T13:09:40Z",
      "released": "2026-09-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15021009M/1/Express-Flash-PCIe-SSD_Firmware_JDM72_WN64_1.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDM72",
      "size": 34969160,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD LC9 E3.S ISE Firmware Release",
      "revision_history": "N/A - Initial Release"
    },
    {
      "id": "26debc4340cd5c9209382ab0b51bd748c6a7d57c8c47529d2c158c26ae92f06a",
      "name": "Dell Express Flash NVMe PCIe SSD 9650 E3.S SED Firmware Release",
      "version": "2.0.0",
      "release_id": "M2F66",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-28T21:40:28Z",
      "released": "2026-08-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14956859M/2/Express-Flash-PCIe-SSD_Firmware_M2F66_WN64_2.0.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M2F66",
      "size": 36092368,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9650 E3.S SED Firmware Release",
      "revision_history": "Fixes:  \nN/A - Initial Release\n\nEnhancements:  \nN/A - Initial Release"
    },
    {
      "id": "9a3186fc16d92d1b19312e4798c15797ac4361d957d529b16e9d646464030560",
      "name": "Dell Express Flash NVMe PCIe SSD CM9 FIPS Firmware Release",
      "version": "3.0.0",
      "release_id": "V2F5P",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-07-27T12:45:32Z",
      "released": "2025-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14825906M/1/Express-Flash-PCIe-SSD_Firmware_V2F5P_WN64_3.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V2F5P",
      "size": 33091336,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM9 FIPS Firmware Release",
      "revision_history": "Fixes:\nN/A - Initial Release\n\nEnhancements:\nN/A - Initial Release"
    },
    {
      "id": "a580760baeeb84608afd5f181fbeb55a18f234396f7b71c2e9803b011bcbd2db",
      "name": "Dell BM1743 NVMe VRI E3.S Gen5 ISE Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "TRP69",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-06-12T20:09:53Z",
      "released": "2026-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14661021M/1/Express-Flash-PCIe-SSD_Firmware_TRP69_WN64_1.2.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TRP69",
      "size": 29641288,
      "reboot_required": false,
      "description": "Dell BM1743 NVMe VRI E3.S Gen5 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n1. Improved PEL logging across power cycles.\n2. Improved NVMe-MI command handling.\n3. Improved critical error messages for OCP 2.0.\n\n\nEnhancements:\n1. Added 4K+8 LBA format capability.\n \nNote: with the addition of the 4K+8 format capability, the firmware is locked to prevent downgrade to earlier versions of drive firmware."
    },
    {
      "id": "9908629a3c6dc68fa7bd50152775a1b55d88d11e66dbd615cc0ee12ee6f32e5c",
      "name": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "HJ15N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-07T10:29:04Z",
      "released": "2025-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14393389M/1/Express-Flash-PCIe-SSD_Firmware_HJ15N_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HJ15N",
      "size": 28267144,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "revision_history": "Fixes:\nN/A - Initial Release\n\nEnhancements:\nN/A - Initial Release"
    },
    {
      "id": "90350549748c451653b5d64fed19ca22671190ef17e5ef4714708a7501e070ab",
      "name": "Dell Express Flash NVMe PCIe SSD CD9P OPAL Firmware Release",
      "version": "2.0.0",
      "release_id": "8D4M2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-07T09:39:20Z",
      "released": "2025-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14393137M/1/Express-Flash-PCIe-SSD_Firmware_8D4M2_WN64_2.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8D4M2",
      "size": 28447400,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD9P OPAL Firmware Release",
      "revision_history": "Fixes:\nN/A - Initial Release\n\nEnhancements:\nN/A - Initial Release"
    },
    {
      "id": "d4514dd54386fc72055663479d5808859a376ab43481c573200ffae5e78e499b",
      "name": "Dell Express Flash NVMe PCIe SSD 7600 E3.S SED Firmware Maintenance Release",
      "version": "2.0.1",
      "release_id": "7X8MM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-03T19:10:06Z",
      "released": "2026-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14385582M/2/Express-Flash-PCIe-SSD_Firmware_7X8MM_WN64_2.0.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7X8MM",
      "size": 34820528,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7600 E3.S SED Firmware Maintenance Release",
      "revision_history": "Fixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "e9e9eb671e92cd921c95ee81a720d782a743494a17f867dc220bdd4d6ece6d62",
      "name": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release",
      "version": "1.1.0",
      "release_id": "WHGGM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-12-16T15:33:37Z",
      "released": "2025-12-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13989869M/1/Express-Flash-PCIe-SSD_Firmware_WHGGM_WN64_1.1.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WHGGM",
      "size": 32600864,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release"
    },
    {
      "id": "fb039e5afaa33e1921395886875a3223bcc51f84107ecfb9c396433e1401fe87",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 E3.S FIPS Firmware Maintenance Release",
      "version": "3.0.4",
      "release_id": "HTH2Y",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-23T22:32:26Z",
      "released": "2025-11-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13901980M/1/Express-Flash-PCIe-SSD_Firmware_HTH2Y_WN64_3.0.4_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HTH2Y",
      "size": 29143760,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 E3.S FIPS Firmware Maintenance Release",
      "revision_history": "Fixes:\n1. To correctly check for overflow during the patrol interval check, by ensuring the patrol read operations proceed as intended and free block generation will also progress normally.\n\nEnhancements:\n1. Add 4k+8 (LBAF2) support"
    }
  ]
}