  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r7725",
  "name": "R7725",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R7725 SAS RAID Updates",
  "filter": "sas-raid",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 16,
      "rss": "/r7725/urgent/rss.xml",
      "api": "/api/r7725/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 78,
      "rss": "/r7725/recommended/rss.xml",
      "api": "/api/r7725/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 42,
      "rss": "/r7725/optional/rss.xml",
      "api": "/api/r7725/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r7725/bios/rss.xml",
      "api": "/api/r7725/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r7725/boss/rss.xml",
      "api": "/api/r7725/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r7725/chipset/rss.xml",
      "api": "/api/r7725/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r7725/diagnostics/rss.xml",
      "api": "/api/r7725/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r7725/drivers-for-os-deployment/rss.xml",
      "api": "/api/r7725/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 40,
      "rss": "/r7725/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r7725/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 6,
      "rss": "/r7725/fibre-channel/rss.xml",
      "api": "/api/r7725/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 2,
      "rss": "/r7725/firmware/rss.xml",
      "api": "/api/r7725/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r7725/idrac/rss.xml",
      "api": "/api/r7725/idrac"
    },
    {
      "slug": "memory",
      "label": "Memory",
      "count": 1,
      "rss": "/r7725/memory/rss.xml",
      "api": "/api/r7725/memory"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 19,
      "rss": "/r7725/network/rss.xml",
      "api": "/api/r7725/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 25,
      "rss": "/r7725/sas-drive/rss.xml",
      "api": "/api/r7725/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 1,
      "rss": "/r7725/sas-non-raid/rss.xml",
      "api": "/api/r7725/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 9,
      "rss": "/r7725/sas-raid/rss.xml",
      "api": "/api/r7725/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/r7725/security/rss.xml",
      "api": "/api/r7725/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 24,
      "rss": "/r7725/serial-ata/rss.xml",
      "api": "/api/r7725/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r7725/systems-management/rss.xml",
      "api": "/api/r7725/systems-management"
    }
  ],
  "count": 9,
  "updates": [
    {
      "id": "4bced7749b6ad9aa5acad3926cb90f65a44e1611a6825834b3ea62f6dbd3af87",
      "name": "PERC H975i Front(A0 \u0026 B0)RAID Controller Firmware Version 8.19.0.0.28-65",
      "version": "8.19.0.0.28-65",
      "release_id": "5F41N",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:46:00Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195111M/2/SAS-RAID_Firmware_5F41N_WN64_8.19.0.0.28-65_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5F41N",
      "size": 36665128,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H975i Front controllers (A0 \u0026 B0) to package 8.19.0.0.28-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "0a074b7baf9230d0123992106f1ffc54676267f5d904e02caacc508913a8c1d9",
      "name": "PERC12 H365i Adapter RAID Controller firmware version 8.19.0.0.15-65",
      "version": "8.19.0.0.15-65",
      "release_id": "32YTC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:44:53Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194860M/2/SAS-RAID_Firmware_32YTC_WN64_8.19.0.0.15-65_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=32YTC",
      "size": 30442896,
      "reboot_required": false,
      "description": "This release updates the firmware residing on H365i Adapter RAID Controller to package8.19.0.0.15-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\nAdded support to import foreign virtual drives with Read-Ahead cache settings by automatically converting them to No Read Ahead during import in eHBA mode.\n \nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis"
    },
    {
      "id": "eb8c58613500f7fca3d7c2821fc2d3abfa37934cbe74e9ff7c06ef831aa28508",
      "name": "PERC H965i Front Controller for Dell PowerEdge 17G Generation of Servers firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "3K8FC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:43:54Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195090M/2/SAS-RAID_Firmware_3K8FC_WN64_8.19.0.0.18-65_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3K8FC",
      "size": 30451176,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H965i Front Controller for Dell PowerEdge 17G Generation of Servers to package 8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "32cba0424a9d705494c82dbc9641cf64613fcacbc440c2497327e80b0f1906c3",
      "name": "PERC12 H965e Adapter RAID Controller firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "378K2",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:41:09Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194809M/2/SAS-RAID_Firmware_378K2_WN64_8.19.0.0.18-65_A10.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=378K2",
      "size": 30451168,
      "reboot_required": false,
      "description": "This release updates the firmware residing on H965e Adapter RAID Controller to package8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "ef67956cb25fd3a7709bd5ab3db4f05c7dcc8cb05a69757e03b5656bc773aa7c",
      "name": "PERC H965i Adapter RAID Controller firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "520P8",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:39:55Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194782M/2/SAS-RAID_Firmware_520P8_WN64_8.19.0.0.18-65_A13.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=520P8",
      "size": 30451152,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H965i Adapter RAID Controller to package 8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active.\nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements:\n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "f451277edca8929f7744d1fcf43bd2ee7276900f4dfbce68d512f2c6fbca83a1",
      "name": "PERC12 H365I DC-MHS RAID Controller firmware version 8.19.0.0.15-65",
      "version": "8.19.0.0.15-65",
      "release_id": "JDRJP",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T06:37:39Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194852M/2/SAS-RAID_Firmware_JDRJP_WN64_8.19.0.0.15-65_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDRJP",
      "size": 30442912,
      "reboot_required": false,
      "description": "PERC12 H365I DC-MHS RAID Controller firmware version 8.19.0.0.15-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\nAdded support to import foreign virtual drives with Read-Ahead cache settings by automatically converting them to No Read Ahead during import in eHBA mode.\n \nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis"
    },
    {
      "id": "a5d07ba978a43fb98b620e9772c2b9781c7c88a95244ad0c3d5d40b728298959",
      "name": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "NKCW4",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-03T15:09:31Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199461M/1/SAS-RAID_Driver_NKCW4_WN64_8.19.6.0_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKCW4",
      "size": 17814352,
      "reboot_required": true,
      "description": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\n\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\n\nDriver Code optimization in IO completion path."
    },
    {
      "id": "c4353be1f75b45627e460e935d416b30929f3c9ceffd49a4970f42706b141bab",
      "name": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "YTR3P",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-02T18:49:59Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195250M/1/SAS-RAID_Driver_YTR3P_WN64_8.19.6.0_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YTR3P",
      "size": 17813192,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\nDriver Code optimization in IO completion path."
    },
    {
      "id": "1dfc69717a0c357d41f49286fe59e78a2c4fcacd649a8c48425eb8d24d3adb47",
      "name": "Windows 2022 drivers for H975i, H965i, H365i and HBA465 controllers",
      "version": "8.14.6.0",
      "release_id": "V3P66",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-09-09T13:37:59Z",
      "released": "2026-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14017149M/4/SAS-RAID_Driver_V3P66_WN64_8.14.6.0_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3P66",
      "size": 17570512,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes:\n=====\nResolved system crash observed after factory reset of the controller.\nFixed issue where crash dump was not generated when Virtualization-Based Security (VBS) was enabled.\n\nEnhancement:\n===========\nNA"
    }
  ]
}