{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r770ap",
  "name": "R770AP",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R770AP Recommended Updates",
  "filter": "recommended",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 5,
      "rss": "/r770ap/urgent/rss.xml",
      "api": "/api/r770ap/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 16,
      "rss": "/r770ap/recommended/rss.xml",
      "api": "/api/r770ap/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 20,
      "rss": "/r770ap/optional/rss.xml",
      "api": "/api/r770ap/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r770ap/bios/rss.xml",
      "api": "/api/r770ap/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r770ap/boss/rss.xml",
      "api": "/api/r770ap/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r770ap/chipset/rss.xml",
      "api": "/api/r770ap/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r770ap/diagnostics/rss.xml",
      "api": "/api/r770ap/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r770ap/drivers-for-os-deployment/rss.xml",
      "api": "/api/r770ap/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 9,
      "rss": "/r770ap/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r770ap/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 5,
      "rss": "/r770ap/fibre-channel/rss.xml",
      "api": "/api/r770ap/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/r770ap/firmware/rss.xml",
      "api": "/api/r770ap/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r770ap/idrac/rss.xml",
      "api": "/api/r770ap/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 13,
      "rss": "/r770ap/network/rss.xml",
      "api": "/api/r770ap/network"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 5,
      "rss": "/r770ap/sas-raid/rss.xml",
      "api": "/api/r770ap/sas-raid"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r770ap/systems-management/rss.xml",
      "api": "/api/r770ap/systems-management"
    }
  ],
  "count": 16,
  "updates": [
    {
      "id": "0977dfbae8a40a6e966730b9138c338cd5e985d9f63aa6ac5dd14dcf8700cee4",
      "name": "iDRAC 1.30.65.51",
      "version": "1.30.65.51",
      "release_id": "C21YH",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-06T13:39:20Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213660M/1/iDRAC-with-Lifecycle-Controller_Firmware_C21YH_WN64_1.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C21YH",
      "size": 357946640,
      "reboot_required": false,
      "description": "iDRAC 1.30.65.51",
      "revision_history": "Fixes\n- Fixed the issue where Serbia was missing from the country code list in the iDRAC SSL/TLS CSR interface.\n- Fixed the issue where iDRAC 1.30.40.51 returns HTTP 400 when accessing Web GUI via FQDN despite HostHeaderCheck being disabled.\n- Fixed the issue where iDRAC time never reverts to RTC if NTP is unavailable.\n- Fixed the issue where SWC9048 error message appears when trying to launch iDRAC IP from UI after updating iDRAC firmware with FIPS enabled.\n- Fixed the issue where SystemCurrentCapLimit and SystemCurrentCapSetting options were missing in racadm get/set system.ServerPwr output while GridCurrentCapLimit settings were exposed.\n- Fixed the issue where STOR090 error occurred when failing to import OMEnt template and SCP when Dedicated HotSpare is present on PERC H965i.\n- Fixed the issue where iDRAC10 SCP export command fails via RACADM for iDRAC firmware version 1.30.40.51.\n- Fixed the issue where GPU Temperature Probe Readings were missing in SNMP and ProbeStatus appeared in unknown state after upgrading to iDRAC 1.30.40.51.\n- Fixed the issue where fans were spinning at 100% when system idle on PowerEdge XE9785 with AMD Pensando Pollara 400 AI Network Interface Card (NIC).\n\n\nEnhancements:\n- Added filter options in iDRAC for SAS address.\n- Fixed the issue where banner for functional pages was still observed when system is in lockdown mode.\n- Added Redfish support to delete AD/LDAP certificates.\n- Populated Redfish Volume Identifiers with durable identifier for PERC RAID virtual disks.\n- Added support to Redfish action EventService.SubmitTestEvent to send test events to Server-Sent Events.\n- Added Redfish support to retrieve configuration preview results for a Job ID.\n- Added Redfish support to reset Storage Controller to defaults.\n- Updated battery page and rollup status design.\n- Added the ability to mount virtual images from S3 for iDRAC.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification.\n- Improved Redfish error messaging for BootSourceOverride failure in iDRAC10.\n- Added OpenID Connect with Azure Entra ID support.\n- Added low privilege iDRAC Operator role.\n- Enabled email alerts for thermal-related GPU/TMP events.\n- Added SMTP modern authentication (OAuth2) support.\n- Enabled email alerts for critical PCI errors (PCI3039/PCI3040) in iDRAC10.\n- Added iDRAC10 BIOS Console Log Retention for serviceability.\n- Added block-level erase and cryptographic validation for iDRAC partitions in SystemErase.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero-Touch Bootstrap.\n- Added support for SID/OPAL/PSID drive status property.\n- Enabled Full APO (Automatic Power On) support for FullPowerReset.\n- Added fan board page health rollup into overall system health.\n- Fixed iDRAC delay in MEM message logging that caused incorrect event ordering.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message.\n- Aligned MultipartUpload ApplyTime behavior with SimpleUpdate (OnStartUpdateRequest).\n- Added BIN Catalog update support.\n- Added native iDRAC10 support for Open Telemetry (OTEL) metric streaming.\n- Added Component-Level Firmware Update and Discoverability via Redfish.\n- Added support for custom HTTP ports for InstallFromRepository via iDRAC UI, Redfish, and RACADM.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior.\n- Added iDRAC support for controlling the SMA_OUT source select.\n- Added support in iDRAC to control the timing module Write_en pin and timing module reset pin with host control via Redfish.\n- Enabled PSU firmware update when single PSU is installed.\n- Added iDRAC CMP V2 support on PowerEdge XR8720T.\n- Added iDRAC uptime to sysinfo.\n- Enhanced iDRAC10 UI usability with VLAN placement, search/filter"
    },
    {
      "id": "76245d0a584c5ccc82e289fc13f517d6fe16339b10aa85c49a062f45e8a4f53d",
      "name": "DELL System Update, v.2.3.0.2",
      "version": "2.3.0.2",
      "release_id": "RDVR3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-11-06T11:10:35Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213121M/1/Systems-Management_Application_RDVR3_WN64_2.3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RDVR3",
      "size": 30983200,
      "reboot_required": false,
      "description": "DELL System Update (DSU) is a software designed to facilitate the application of updates on various Dell systems. Using DSU you can:\n1.Identify the available updates, select the relevant updates, and deploy the updates on multiple systems.\n2.Maintain consistency in terms of interface and versions across Operating Systems, Repositories, and Systems.",
      "revision_history": "Enhancement :\n\nOS native support with passthrough and rsystemtype iDRAC \n\nFixes :\n\nSecurity Issues"
    },
    {
      "id": "4bced7749b6ad9aa5acad3926cb90f65a44e1611a6825834b3ea62f6dbd3af87",
      "name": "PERC H975i Front(A0 \u0026 B0)RAID Controller Firmware Version 8.19.0.0.28-65",
      "version": "8.19.0.0.28-65",
      "release_id": "5F41N",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:46:00Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195111M/2/SAS-RAID_Firmware_5F41N_WN64_8.19.0.0.28-65_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5F41N",
      "size": 36665128,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H975i Front controllers (A0 \u0026 B0) to package 8.19.0.0.28-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "eb8c58613500f7fca3d7c2821fc2d3abfa37934cbe74e9ff7c06ef831aa28508",
      "name": "PERC H965i Front Controller for Dell PowerEdge 17G Generation of Servers firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "3K8FC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:43:54Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195090M/2/SAS-RAID_Firmware_3K8FC_WN64_8.19.0.0.18-65_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3K8FC",
      "size": 30451176,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H965i Front Controller for Dell PowerEdge 17G Generation of Servers to package 8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "a5d07ba978a43fb98b620e9772c2b9781c7c88a95244ad0c3d5d40b728298959",
      "name": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "NKCW4",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-03T15:09:31Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199461M/1/SAS-RAID_Driver_NKCW4_WN64_8.19.6.0_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKCW4",
      "size": 17814352,
      "reboot_required": true,
      "description": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\n\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\n\nDriver Code optimization in IO completion path."
    },
    {
      "id": "c4353be1f75b45627e460e935d416b30929f3c9ceffd49a4970f42706b141bab",
      "name": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "YTR3P",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-02T18:49:59Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195250M/1/SAS-RAID_Driver_YTR3P_WN64_8.19.6.0_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YTR3P",
      "size": 17813192,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\nDriver Code optimization in IO completion path."
    },
    {
      "id": "1946160ed0d0cb3359a20dfca14e8078ecac5f014fd8979c0efcaa3a71e82245",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "version": "1.1.0",
      "release_id": "4WN4V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-23T16:20:58Z",
      "released": "2026-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14428501M/2/Express-Flash-PCIe-SSD_Firmware_4WN4V_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4WN4V",
      "size": 34529136,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n1. Modified the FW to track second level read recovery triggers.\n2. Developed a firmware fix to add separate queues in the CPU coupled memory to monitor and control the flow of push \u0026 pop entries in the linked list to eliminate any possibility of unexpected concurrent accesses. A dedicated CPU is used for this solution to minimize performance impact.\n3. Modified the FW to set the pointer value to the designated structured memory area.\n4. Updated the firmware to optimize internal operations under this back-to-back power cycle scenario to properly manage APL interrupt.\n5. Updated the firmware to check the thermal throttling stage and manage the resource allocation appropriately before the initiating APL handling.\n6. Enhanced the firmware to handle the back-to-back PERST# operations to ensure that no transitions are missed.\n7. Updated the firmware to increase the PCIe bridge timeout to 1ms\n\nEnhancements:  \n1. Updated the FW to increase the CAP.TO value to 30 seconds for 9550 product family\n2. Updated the Firmware to correct the eye measurement algorithm to appropriately handle PCIe errors conditions.\n3. Enhanced the firmware to optimize folding operations under these specific workloads to improve performance consistency.\n4. Updated the firmware to keep the activity LED on when the host disables the controller (CC.EN=0)"
    },
    {
      "id": "1dfc69717a0c357d41f49286fe59e78a2c4fcacd649a8c48425eb8d24d3adb47",
      "name": "Windows 2022 drivers for H975i, H965i, H365i and HBA465 controllers",
      "version": "8.14.6.0",
      "release_id": "V3P66",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-09-09T13:37:59Z",
      "released": "2026-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14017149M/4/SAS-RAID_Driver_V3P66_WN64_8.14.6.0_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3P66",
      "size": 17570512,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes:\n=====\nResolved system crash observed after factory reset of the controller.\nFixed issue where crash dump was not generated when Virtualization-Based Security (VBS) was enabled.\n\nEnhancement:\n===========\nNA"
    },
    {
      "id": "3f87c21df5810c68963cccd41629f2fbe9becdc480e79830e112cf9b71521b5f",
      "name": "Dell Firmware Update Package for Marvell/QLogic 2740 and 2770 series Fibre Channel adapters",
      "version": "17.15.05",
      "release_id": "TJR2C",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-02T07:10:43Z",
      "released": "2026-06-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14632958M/2/Fibre-Channel_Firmware_TJR2C_WN64_17.15.05_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TJR2C",
      "size": 27218880,
      "reboot_required": true,
      "description": "This software bundle includes a Dell Firmware Update Package for Marvell/QLogic Fibre Channel adapters."
    },
    {
      "id": "114a5ffb50ea56f3f130e6716fa5a9765323094f10d2a9da7d1286262553165b",
      "name": "Windows drivers for Marvell QLogic Fibre Channel adapters",
      "version": "37.15.05",
      "release_id": "XNTFF",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-06-06T05:26:27Z",
      "released": "2026-06-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14633058M/1/Network_Driver_XNTFF_WN64_37.15.05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XNTFF",
      "size": 28365248,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Update Package with Windows Drivers for Marvell adapters."
    },
    {
      "id": "2934568380f2339f182517e5d3f9ba9e30dcc5866f84d513afff005bc9ee2c57",
      "name": "NVIDIA Mellanox Windows 64-bit Server OS Drivers for Mellanox ConnectX-4 LX, ConnectX-5, ConnectX-6 and ConnectX-7, ConnectX-8 Adapters",
      "version": "25.07",
      "release_id": "PWYXM",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2025-11-14T21:18:11Z",
      "released": "2025-10-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13711201M/2/Network_Driver_PWYXM_WN64_25.07_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PWYXM",
      "size": 281101144,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, and ConnectX-7, ConnectX-8 NIC drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "e8b65ff00e275e639b334ffd4d2ef7d6f849b4d4c3a399a75b6d2614b2f03861",
      "name": "NVIDIA Mellanox Firmware Release 22.46.3048 for the Industry-Standard NVIDIA Mellanox ConnectX-6 DX Ethernet Adapters",
      "version": "22.46.3048",
      "release_id": "VJWGJ",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-03T02:25:59Z",
      "released": "2025-10-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13711083M/4/Network_Firmware_VJWGJ_WN64_22.46.3048_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJWGJ",
      "size": 41884712,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 22.46.3048 on the industry-standard NVIDIA Mellanox ConnectX-6 DX adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "805ad4d6fae682c4e0a01345f1744468d44751ff8f996c9a6dadd779829f88b1",
      "name": "NVIDIA Mellanox Firmware Release 26.46.3048 for the Industry-Standard NVIDIA Mellanox ConnectX-6 LX Ethernet Adapters",
      "version": "26.46.3048",
      "release_id": "D81J3",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-03T02:22:06Z",
      "released": "2025-10-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13710928M/5/Network_Firmware_D81J3_WN64_26.46.3048_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D81J3",
      "size": 41368832,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 26.46.3048 on the industry-standard NVIDIA Mellanox ConnectX-6 LX adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "0c6c5d8e99dc5a2c2919fcbf8671edcb68c45a499387a8e98295560fc88772c6",
      "name": "NVIDIA Mellanox Firmware Release 28.46.3048 for the Industry-Standard NVIDIA Mellanox ConnectX-7 NDR Adapters",
      "version": "28.46.3048",
      "release_id": "MW3TN",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-10-24T15:05:25Z",
      "released": "2025-10-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13710959M/4/Network_Firmware_MW3TN_WN64_28.46.3048_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MW3TN",
      "size": 52782680,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 28.46.3048 on the industry-standard NVIDIA Mellanox ConnectX-7 Single Port NDR OSFP adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "03de1d08414a2b511614268e4a3d7ddf38fb318e34a27f7dec7fcf35c69497f2",
      "name": "Dell Express Flash NVMe PCIe SSD CM6 FIPS Maintenance Firmware Release",
      "version": "3.1.7",
      "release_id": "WJD95",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-10T05:56:19Z",
      "released": "2024-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11856439M/3/Express-Flash-PCIe-SSD_Firmware_WJD95_WN64_3.1.7_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WJD95",
      "size": 28731088,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM6 FIPS Firmware Maintenance Release",
      "revision_history": "N/A"
    },
    {
      "id": "e1c9baab746a197329509da4e36ba1d2db44f75dc2a71e34e37910ece96bb56b",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 E3.S ISE Firmware Maintenance Release",
      "version": "2.0.2",
      "release_id": "N43V2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-23T17:03:30Z",
      "released": "2025-04-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13157812M/1/Express-Flash-PCIe-SSD_Firmware_N43V2_WN64_2.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N43V2",
      "size": 29819040,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo Be added"
    }
  ]
}
