{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "r770",
  "name": "R770",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R770 Updates",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 12,
      "rss": "/r770/urgent/rss.xml",
      "api": "/api/r770/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 50,
      "rss": "/r770/recommended/rss.xml",
      "api": "/api/r770/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 42,
      "rss": "/r770/optional/rss.xml",
      "api": "/api/r770/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r770/bios/rss.xml",
      "api": "/api/r770/bios"
    },
    {
      "slug": "bmc",
      "label": "BMC",
      "count": 1,
      "rss": "/r770/bmc/rss.xml",
      "api": "/api/r770/bmc"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r770/boss/rss.xml",
      "api": "/api/r770/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r770/chipset/rss.xml",
      "api": "/api/r770/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r770/diagnostics/rss.xml",
      "api": "/api/r770/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r770/drivers-for-os-deployment/rss.xml",
      "api": "/api/r770/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 40,
      "rss": "/r770/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r770/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 6,
      "rss": "/r770/fibre-channel/rss.xml",
      "api": "/api/r770/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 2,
      "rss": "/r770/firmware/rss.xml",
      "api": "/api/r770/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r770/idrac/rss.xml",
      "api": "/api/r770/idrac"
    },
    {
      "slug": "memory",
      "label": "Memory",
      "count": 1,
      "rss": "/r770/memory/rss.xml",
      "api": "/api/r770/memory"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 23,
      "rss": "/r770/network/rss.xml",
      "api": "/api/r770/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 5,
      "rss": "/r770/sas-drive/rss.xml",
      "api": "/api/r770/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 1,
      "rss": "/r770/sas-non-raid/rss.xml",
      "api": "/api/r770/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 8,
      "rss": "/r770/sas-raid/rss.xml",
      "api": "/api/r770/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/r770/security/rss.xml",
      "api": "/api/r770/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 8,
      "rss": "/r770/serial-ata/rss.xml",
      "api": "/api/r770/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r770/systems-management/rss.xml",
      "api": "/api/r770/systems-management"
    }
  ],
  "count": 104,
  "updates": [
    {
      "id": "837f52bcdf77c2d14310498f7dd4952e13c37aa4c6fdc01265b9a428e061657d",
      "name": "Dell EMC iDRAC Service Module Installer for OS DUP, v6.2.0.0",
      "version": "6.2.0.0",
      "release_id": "JDJH3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-11-09T07:17:23Z",
      "released": "2026-10-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15095008M/5/Systems-Management_Application_JDJH3_WN64_6.2.0.0_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDJH3",
      "size": 34422592,
      "reboot_required": false,
      "description": "iDRAC Service Module (iSM) is a lightweight software service that better integrates operating system (OS) features with iDRAC and can be installed on Dell PowerEdge 15G and above servers. iSM provides OS-related information to iDRAC and adds capabilities such as Lifecycle Controller log event replication into the OS log, iDRAC SNMP alerts via OS, iDRAC hard reset and remote full Power Cycle. iSM has very little impact on the host processor and smaller memory footprint, thus expanding iDRAC management to the supported host operating systems.",
      "revision_history": "NA"
    },
    {
      "id": "195a4057abc496928a98045e4fa6945078fe224fc55c5822aa93847b5a2eedeb",
      "name": "Dell Server PowerEdge BIOS Version 1.10.5",
      "version": "1.10.5",
      "release_id": "17J7V",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-11-09T06:08:57Z",
      "released": "2026-11-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15216591M/1/BIOS_17J7V_WN64_1.10.5.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17J7V",
      "size": 47237984,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced feature sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Fixes:\n- Fixed an issue where the PXE boot device selection could incorrectly map to the wrong NIC interface\nEnhancements:\n- Updated the following:\n- Intel processor and memory reference codes in the Unified Post Launch Release 5 v3545.P.53\n- Intel processor microcode to version 0x3C4 in the Intel Xeon 6700E-series Processors.\n- Intel processor microcode to version 0x164 in the Intel Xeon 6500P-series and 6700P-series Rich I/O Processors\n- Intel processor microcode to version 0x444 in the Intel Xeon 6500P-series and 6700P-series Processors\n- Intel Trusted Domain Extension (TDX) to version 1.5.36.04.1073 for the Intel(R) Xeon(R) 6700E-series Processors\n- Intel Trusted Domain Extension (TDX) to version 2.0.20.00.1074 for the Intel Xeon 6500P-series and 6700P-series Processors\n- Integrated Dell Remote Access Controller (iDRAC) HII settings engine to version 6.0.0.34.\n- Support GNR CPU 2DPC memory configurations up to 6000 MT/s.\n- This product release contains security update DSA-2026-470 and DSA-2026-471. Any security fix information will be accessible on the Dell Security Advisories and Notices website."
    },
    {
      "id": "0977dfbae8a40a6e966730b9138c338cd5e985d9f63aa6ac5dd14dcf8700cee4",
      "name": "iDRAC 1.30.65.51",
      "version": "1.30.65.51",
      "release_id": "C21YH",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-06T13:39:20Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213660M/1/iDRAC-with-Lifecycle-Controller_Firmware_C21YH_WN64_1.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C21YH",
      "size": 357946640,
      "reboot_required": false,
      "description": "iDRAC 1.30.65.51",
      "revision_history": "Fixes\n- Fixed the issue where Serbia was missing from the country code list in the iDRAC SSL/TLS CSR interface.\n- Fixed the issue where iDRAC 1.30.40.51 returns HTTP 400 when accessing Web GUI via FQDN despite HostHeaderCheck being disabled.\n- Fixed the issue where iDRAC time never reverts to RTC if NTP is unavailable.\n- Fixed the issue where SWC9048 error message appears when trying to launch iDRAC IP from UI after updating iDRAC firmware with FIPS enabled.\n- Fixed the issue where SystemCurrentCapLimit and SystemCurrentCapSetting options were missing in racadm get/set system.ServerPwr output while GridCurrentCapLimit settings were exposed.\n- Fixed the issue where STOR090 error occurred when failing to import OMEnt template and SCP when Dedicated HotSpare is present on PERC H965i.\n- Fixed the issue where iDRAC10 SCP export command fails via RACADM for iDRAC firmware version 1.30.40.51.\n- Fixed the issue where GPU Temperature Probe Readings were missing in SNMP and ProbeStatus appeared in unknown state after upgrading to iDRAC 1.30.40.51.\n- Fixed the issue where fans were spinning at 100% when system idle on PowerEdge XE9785 with AMD Pensando Pollara 400 AI Network Interface Card (NIC).\n\n\nEnhancements:\n- Added filter options in iDRAC for SAS address.\n- Fixed the issue where banner for functional pages was still observed when system is in lockdown mode.\n- Added Redfish support to delete AD/LDAP certificates.\n- Populated Redfish Volume Identifiers with durable identifier for PERC RAID virtual disks.\n- Added support to Redfish action EventService.SubmitTestEvent to send test events to Server-Sent Events.\n- Added Redfish support to retrieve configuration preview results for a Job ID.\n- Added Redfish support to reset Storage Controller to defaults.\n- Updated battery page and rollup status design.\n- Added the ability to mount virtual images from S3 for iDRAC.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification.\n- Improved Redfish error messaging for BootSourceOverride failure in iDRAC10.\n- Added OpenID Connect with Azure Entra ID support.\n- Added low privilege iDRAC Operator role.\n- Enabled email alerts for thermal-related GPU/TMP events.\n- Added SMTP modern authentication (OAuth2) support.\n- Enabled email alerts for critical PCI errors (PCI3039/PCI3040) in iDRAC10.\n- Added iDRAC10 BIOS Console Log Retention for serviceability.\n- Added block-level erase and cryptographic validation for iDRAC partitions in SystemErase.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero-Touch Bootstrap.\n- Added support for SID/OPAL/PSID drive status property.\n- Enabled Full APO (Automatic Power On) support for FullPowerReset.\n- Added fan board page health rollup into overall system health.\n- Fixed iDRAC delay in MEM message logging that caused incorrect event ordering.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message.\n- Aligned MultipartUpload ApplyTime behavior with SimpleUpdate (OnStartUpdateRequest).\n- Added BIN Catalog update support.\n- Added native iDRAC10 support for Open Telemetry (OTEL) metric streaming.\n- Added Component-Level Firmware Update and Discoverability via Redfish.\n- Added support for custom HTTP ports for InstallFromRepository via iDRAC UI, Redfish, and RACADM.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior.\n- Added iDRAC support for controlling the SMA_OUT source select.\n- Added support in iDRAC to control the timing module Write_en pin and timing module reset pin with host control via Redfish.\n- Enabled PSU firmware update when single PSU is installed.\n- Added iDRAC CMP V2 support on PowerEdge XR8720T.\n- Added iDRAC uptime to sysinfo.\n- Enhanced iDRAC10 UI usability with VLAN placement, search/filter"
    },
    {
      "id": "76245d0a584c5ccc82e289fc13f517d6fe16339b10aa85c49a062f45e8a4f53d",
      "name": "DELL System Update, v.2.3.0.2",
      "version": "2.3.0.2",
      "release_id": "RDVR3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-11-06T11:10:35Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213121M/1/Systems-Management_Application_RDVR3_WN64_2.3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RDVR3",
      "size": 30983200,
      "reboot_required": false,
      "description": "DELL System Update (DSU) is a software designed to facilitate the application of updates on various Dell systems. Using DSU you can:\n1.Identify the available updates, select the relevant updates, and deploy the updates on multiple systems.\n2.Maintain consistency in terms of interface and versions across Operating Systems, Repositories, and Systems.",
      "revision_history": "Enhancement :\n\nOS native support with passthrough and rsystemtype iDRAC \n\nFixes :\n\nSecurity Issues"
    },
    {
      "id": "c9e0e64c1db238a4e86cf4b4845476f22bf99bb669c4039ede114cae0be57fe0",
      "name": "HBA465e Adapter Non-RAID Controller firmware version 8.19.0.0.15-65",
      "version": "8.19.0.0.15-65",
      "release_id": "9FT9J",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:49:36Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195074M/3/SAS-Non-RAID_Firmware_9FT9J_WN64_8.19.0.0.15-65_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9FT9J",
      "size": 30440440,
      "reboot_required": false,
      "description": "This release updates the firmware residing on HBA465e Adapter controller to package 8.19.0.0.15-65",
      "revision_history": "Fixes\n=====\nFixed an issue where duplicate sanitize monitors could be created after a firmware reboot during sanitize operations. \n \nEnhancements\n============\nOptimizations and Improvements from Static Code Analysis"
    },
    {
      "id": "4bced7749b6ad9aa5acad3926cb90f65a44e1611a6825834b3ea62f6dbd3af87",
      "name": "PERC H975i Front(A0 \u0026 B0)RAID Controller Firmware Version 8.19.0.0.28-65",
      "version": "8.19.0.0.28-65",
      "release_id": "5F41N",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:46:00Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195111M/2/SAS-RAID_Firmware_5F41N_WN64_8.19.0.0.28-65_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5F41N",
      "size": 36665128,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H975i Front controllers (A0 \u0026 B0) to package 8.19.0.0.28-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "0a074b7baf9230d0123992106f1ffc54676267f5d904e02caacc508913a8c1d9",
      "name": "PERC12 H365i Adapter RAID Controller firmware version 8.19.0.0.15-65",
      "version": "8.19.0.0.15-65",
      "release_id": "32YTC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:44:53Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194860M/2/SAS-RAID_Firmware_32YTC_WN64_8.19.0.0.15-65_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=32YTC",
      "size": 30442896,
      "reboot_required": false,
      "description": "This release updates the firmware residing on H365i Adapter RAID Controller to package8.19.0.0.15-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\nAdded support to import foreign virtual drives with Read-Ahead cache settings by automatically converting them to No Read Ahead during import in eHBA mode.\n \nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis"
    },
    {
      "id": "eb8c58613500f7fca3d7c2821fc2d3abfa37934cbe74e9ff7c06ef831aa28508",
      "name": "PERC H965i Front Controller for Dell PowerEdge 17G Generation of Servers firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "3K8FC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:43:54Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195090M/2/SAS-RAID_Firmware_3K8FC_WN64_8.19.0.0.18-65_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3K8FC",
      "size": 30451176,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H965i Front Controller for Dell PowerEdge 17G Generation of Servers to package 8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "32cba0424a9d705494c82dbc9641cf64613fcacbc440c2497327e80b0f1906c3",
      "name": "PERC12 H965e Adapter RAID Controller firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "378K2",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:41:09Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194809M/2/SAS-RAID_Firmware_378K2_WN64_8.19.0.0.18-65_A10.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=378K2",
      "size": 30451168,
      "reboot_required": false,
      "description": "This release updates the firmware residing on H965e Adapter RAID Controller to package8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "f451277edca8929f7744d1fcf43bd2ee7276900f4dfbce68d512f2c6fbca83a1",
      "name": "PERC12 H365I DC-MHS RAID Controller firmware version 8.19.0.0.15-65",
      "version": "8.19.0.0.15-65",
      "release_id": "JDRJP",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T06:37:39Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194852M/2/SAS-RAID_Firmware_JDRJP_WN64_8.19.0.0.15-65_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDRJP",
      "size": 30442912,
      "reboot_required": false,
      "description": "PERC12 H365I DC-MHS RAID Controller firmware version 8.19.0.0.15-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\nAdded support to import foreign virtual drives with Read-Ahead cache settings by automatically converting them to No Read Ahead during import in eHBA mode.\n \nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis"
    },
    {
      "id": "3c42a5d5d6593d1bb6afbb03bfc0943458d93671a8a9b79d91ec42193d56871e",
      "name": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "GF3PY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-11-03T17:31:07Z",
      "released": "2026-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199882M/1/Express-Flash-PCIe-SSD_Firmware_GF3PY_WN64_1.5.0_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GF3PY",
      "size": 38306408,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release"
    },
    {
      "id": "a5d07ba978a43fb98b620e9772c2b9781c7c88a95244ad0c3d5d40b728298959",
      "name": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "NKCW4",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-03T15:09:31Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199461M/1/SAS-RAID_Driver_NKCW4_WN64_8.19.6.0_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKCW4",
      "size": 17814352,
      "reboot_required": true,
      "description": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\n\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\n\nDriver Code optimization in IO completion path."
    },
    {
      "id": "c4353be1f75b45627e460e935d416b30929f3c9ceffd49a4970f42706b141bab",
      "name": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "YTR3P",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-02T18:49:59Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195250M/1/SAS-RAID_Driver_YTR3P_WN64_8.19.6.0_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YTR3P",
      "size": 17813192,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\nDriver Code optimization in IO completion path."
    },
    {
      "id": "69a58ee638d7dd383229f7edeb9f9319c1937db810aeee75697ddd20288506cc",
      "name": "NVIDIA Mellanox Windows 64-bit Server OS Drivers for Mellanox ConnectX-4 LX, ConnectX-5, ConnectX-6 and ConnectX-7, ConnectX-8 Adapters",
      "version": "25.010.100",
      "release_id": "054K7",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-02T07:42:07Z",
      "released": "2026-08-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14932497M/2/Network_Driver_054K7_WN64_25.010.100_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=054K7",
      "size": 322683056,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, and ConnectX-7, ConnectX-8 NIC drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "ccfd97107a9e25cbcb63ee627c90e940b3e098b5ead03496e601bf10d5e1ba88",
      "name": "Dell Express Flash NVMe PCIe SSD 6550 E3.S ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "P9DGW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-29T13:23:21Z",
      "released": "2025-06-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13313249M/2/Express-Flash-PCIe-SSD_Firmware_P9DGW_WN64_1.0.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P9DGW",
      "size": 34411896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 6550 E3.S ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any RHEL and Ubuntu OS. Either use Windows SLES or iDRAC for FW update - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "5bbdae55feec05548f25c7f818060529f1a3e4aef24e5c08c863d804cdce751d",
      "name": "Broadcom 5741X, 57502, 57608 Network Device Firmware (Industry) 23.8.1",
      "version": "238.1.191.0",
      "release_id": "MJFY0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-10-15T21:13:46Z",
      "released": "2026-10-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15134026M/1/Network_Firmware_MJFY0_WN64_238.1.191.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MJFY0",
      "size": 68102160,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for the Broadcom NetXtreme-E devices.   This release should be used with the Broadcom NetXtreme-E 23.8 device drivers. Note: This firmware may require a cold reboot after installation.",
      "revision_history": "Fixes:\n- BCM57414 2x25G OCP partition link status is reported as \"unknown\" by iDRAC.\n- PCIe PTM enabled on 5750x/57608 without verifying upstream device PTM state.\n- AI-assisted code improvements.\n\nEnhancements:\n- Add support for Ubuntu 26.04. \n- Add support for RHEL 9.7, 9.8, 10.1, and 10.2.\n- Add support for rebootless firmware activation.\n- Add support for configuration attributes including Virtual MAC address"
    },
    {
      "id": "318fefd2743ce3a042428d9e8d722b8a862af777cc9df710c689ecd125c66516",
      "name": "Broadcom NetXtreme-E Network Device Firmware (Dell) 23.8.1",
      "version": "38.11.91.00",
      "release_id": "H3TR4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-10-13T23:36:18Z",
      "released": "2026-10-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15122845M/1/Network_Firmware_H3TR4_WN64_38.11.91.00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3TR4",
      "size": 84351360,
      "reboot_required": false,
      "description": "This release provides updated network controller firmware for the Broadcom NetXtreme-E devices.   This release should be used with the Broadcom NetXtreme-E 23.8 device drivers."
    },
    {
      "id": "eeabb26543e42cb0c06dfa7c810aad0eefba853a9ed84fcf5a217cf1cf793607",
      "name": "NVIDIA Mellanox Firmware Release 28.50.1002 for the Industry-Standard NVIDIA Mellanox ConnectX-7 NDR Adapters",
      "version": "28.50.1002",
      "release_id": "GC3NG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-10-02T22:05:47Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15088418M/1/Network_Firmware_GC3NG_WN64_28.50.1002_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GC3NG",
      "size": 76977584,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 28.50.1002 on the industry-standard NVIDIA Mellanox ConnectX-7 NDR OSFP adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "2784cac0b8b58ea70ad630208898d6eb97e9b03ca201d3538f7cdf540045f1b2",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N",
      "version": "1.3.1",
      "release_id": "VMDWF",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:48Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652186M/3/Express-Flash-PCIe-SSD_Firmware_VMDWF_WN64_1.3.1_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VMDWF",
      "size": 28699000,
      "reboot_required": true,
      "description": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N.",
      "revision_history": "Fixes: \n\nFW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "55fdb9edfa7c9812935543decb2ff483697791b2d6eb1753f8ee91ce4aadeb79",
      "name": "NVIDIA Mellanox Firmware Release 26.50.1002 for the Industry-Standard NVIDIA Mellanox ConnectX-6 LX Ethernet Adapters",
      "version": "26.50.1002",
      "release_id": "X3HC5",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T20:46:03Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15081191M/1/Network_Firmware_X3HC5_WN64_26.50.1002_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X3HC5",
      "size": 45924000,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 26.50.1002 on the industry-standard NVIDIA Mellanox ConnectX-6 LX adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "6aaa2310a0ed6f11b7f9b8ff4e667872695e945ef6dccd1bac1983b8ca2a9cc6",
      "name": "NVIDIA Mellanox Firmware Release 22.50.1002 for the Industry-Standard NVIDIA Mellanox ConnectX-6 DX Ethernet Adapters",
      "version": "22.50.1002",
      "release_id": "D4HHF",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T15:36:43Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15080448M/1/Network_Firmware_D4HHF_WN64_22.50.1002_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D4HHF",
      "size": 46441984,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 22.50.1002 on the industry-standard NVIDIA Mellanox ConnectX-6 DX adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "61aa072fa29c265fba04bfc1d6f2e6ccc306cc141882c41aa143d899f00c9928",
      "name": "NVIDIA Mellanox Windows 64-bit Server OS Drivers for Mellanox ConnectX-4 LX, ConnectX-5, ConnectX-6, ConnectX-7, ConnectX-8 and ConnectX-9 Adapters",
      "version": "26.007.01",
      "release_id": "0PT26",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-09-29T19:07:51Z",
      "released": "2026-09-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15074840M/1/Network_Driver_0PT26_WN64_26.007.01_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0PT26",
      "size": 395045064,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, ConnectX-7, ConnectX-8 and ConnectX-9 NIC drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update."
    },
    {
      "id": "1946160ed0d0cb3359a20dfca14e8078ecac5f014fd8979c0efcaa3a71e82245",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "version": "1.1.0",
      "release_id": "4WN4V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-23T16:20:58Z",
      "released": "2026-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14428501M/2/Express-Flash-PCIe-SSD_Firmware_4WN4V_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4WN4V",
      "size": 34529136,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 and E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n1. Modified the FW to track second level read recovery triggers.\n2. Developed a firmware fix to add separate queues in the CPU coupled memory to monitor and control the flow of push \u0026 pop entries in the linked list to eliminate any possibility of unexpected concurrent accesses. A dedicated CPU is used for this solution to minimize performance impact.\n3. Modified the FW to set the pointer value to the designated structured memory area.\n4. Updated the firmware to optimize internal operations under this back-to-back power cycle scenario to properly manage APL interrupt.\n5. Updated the firmware to check the thermal throttling stage and manage the resource allocation appropriately before the initiating APL handling.\n6. Enhanced the firmware to handle the back-to-back PERST# operations to ensure that no transitions are missed.\n7. Updated the firmware to increase the PCIe bridge timeout to 1ms\n\nEnhancements:  \n1. Updated the FW to increase the CAP.TO value to 30 seconds for 9550 product family\n2. Updated the Firmware to correct the eye measurement algorithm to appropriately handle PCIe errors conditions.\n3. Enhanced the firmware to optimize folding operations under these specific workloads to improve performance consistency.\n4. Updated the firmware to keep the activity LED on when the host disables the controller (CC.EN=0)"
    },
    {
      "id": "48c5469a4a346a44cc4729143b3df57c3c9d8a12638878a02ea6a9cd86561b51",
      "name": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "version": "1.0.2",
      "release_id": "1W7Y8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-22T19:07:37Z",
      "released": "2026-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568456M/2/Express-Flash-PCIe-SSD_Firmware_1W7Y8_WN64_1.0.2_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1W7Y8",
      "size": 35321280,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected SPDM data offset used when calculating the SPDM manifest.\n2. Enhanced NVMe-MI logic.\n3. Fixed NVMe-MI message response delays; reponses to all NVMe-MI messages within a 100ms timeout period.\n4. Restrict SMBus communication to when the drive is ready to service MCTP/Basic.\n\nEnhancements:\n\n1. Enhanced MCTP processing over SMBus while SMBus is in a reset state.\n2. DUP support for ARM platforms added.\n3. DUP support updated for PERC 12 and 13."
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "fcaa808d62c877106d9e10016f37065f99096929161fea64791ad02e599e67f9",
      "name": "Dell Express Flash NVMe PCIe SSD LC9 E3.S ISE Firmware Release",
      "version": "1.0.4",
      "release_id": "JDM72",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-14T13:09:40Z",
      "released": "2026-09-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15021009M/1/Express-Flash-PCIe-SSD_Firmware_JDM72_WN64_1.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDM72",
      "size": 34969160,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD LC9 E3.S ISE Firmware Release",
      "revision_history": "N/A - Initial Release"
    },
    {
      "id": "1dfc69717a0c357d41f49286fe59e78a2c4fcacd649a8c48425eb8d24d3adb47",
      "name": "Windows 2022 drivers for H975i, H965i, H365i and HBA465 controllers",
      "version": "8.14.6.0",
      "release_id": "V3P66",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-09-09T13:37:59Z",
      "released": "2026-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14017149M/4/SAS-RAID_Driver_V3P66_WN64_8.14.6.0_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3P66",
      "size": 17570512,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes:\n=====\nResolved system crash observed after factory reset of the controller.\nFixed issue where crash dump was not generated when Virtualization-Based Security (VBS) was enabled.\n\nEnhancement:\n===========\nNA"
    },
    {
      "id": "522f28802cea2f9aec5eda764700aca47a4f055f347f76d1936baadbc40f0c14",
      "name": "Dell Firmware Update Package for Marvell/QLogic QLE2872C series Fibre Channel adapters",
      "version": "17.15.05",
      "release_id": "97M78",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-02T07:15:03Z",
      "released": "2026-06-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14633014M/2/Fibre-Channel_Firmware_97M78_WN64_17.15.05_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=97M78",
      "size": 24324744,
      "reboot_required": true,
      "description": "This software bundle includes a Dell Firmware Update Package for Marvell/QLogic Fibre Channel adapters"
    },
    {
      "id": "3f87c21df5810c68963cccd41629f2fbe9becdc480e79830e112cf9b71521b5f",
      "name": "Dell Firmware Update Package for Marvell/QLogic 2740 and 2770 series Fibre Channel adapters",
      "version": "17.15.05",
      "release_id": "TJR2C",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-02T07:10:43Z",
      "released": "2026-06-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14632958M/2/Fibre-Channel_Firmware_TJR2C_WN64_17.15.05_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TJR2C",
      "size": 27218880,
      "reboot_required": true,
      "description": "This software bundle includes a Dell Firmware Update Package for Marvell/QLogic Fibre Channel adapters."
    },
    {
      "id": "d71b01eb75a0c765cf5a89ead6d25650c8340f2b1e6eeff421960d14497e52bb",
      "name": "Emulex Fibre Channel Adapter Firmware.",
      "version": "03.10.20",
      "release_id": "PR4Y6",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-01T18:00:15Z",
      "released": "2026-09-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14968707M/1/Fibre-Channel_Firmware_PR4Y6_WN64_03.10.20_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PR4Y6",
      "size": 29617096,
      "reboot_required": false,
      "description": "Dell Update Package for updating firmware on the Emulex Fibre Channel adapters",
      "revision_history": "Fixes:\n- JIT-373621: Emulex LPe35002| R660xs| FC HBA disappear after warm boot."
    },
    {
      "id": "f8258a50648c5a12cb7cce4ecf077cdaa230dc07ab048c86804b7c2927167a46",
      "name": "Dell Express Flash NVMe PCIe SSD 6600 U.2 ISE Firmware Release",
      "version": "1.1.0",
      "release_id": "XV47M",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-08-31T19:06:53Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14962809M/1/Express-Flash-PCIe-SSD_Firmware_XV47M_WN64_1.1.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XV47M",
      "size": 36354320,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 6600 U.2 ISE Firmware Release",
      "revision_history": "Fixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "102936626baf4012dbcb2aa197a49052eb95905aa41bb5454a517e5a542f21d5",
      "name": "BOSS-N1 DC-MHS Firmware",
      "version": "2.2.13.2038",
      "release_id": "GDT3C",
      "category": "BOSS",
      "category_slug": "boss",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-24T08:38:12Z",
      "released": "2026-05-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14431646M/3/BOSS_Firmware_GDT3C_WN64_2.2.13.2038_A05_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GDT3C",
      "size": 23307616,
      "reboot_required": true,
      "description": "17G BOSS-N1 DC-MHS Package Version 2.2.13.2038",
      "revision_history": "Addressed and improved IO completion status handling"
    },
    {
      "id": "b31af8d25442f47d287b9165621c02201f15b930f033645f7c931dba1ce3dae7",
      "name": "Dell OS Driver Pack",
      "version": "26.08.02",
      "release_id": "5XVNX",
      "category": "Drivers for OS Deployment",
      "category_slug": "drivers-for-os-deployment",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-08-17T06:37:41Z",
      "released": "2026-08-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14907780M/1/Drivers-for-OS-Deployment_Application_5XVNX_WN64_26.08.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5XVNX",
      "size": 52811920,
      "reboot_required": false,
      "description": "OS Driver Pack for PowerEdge 17G servers. This Driver Pack contains applicable storage, Drivers for OCP cards and chipset drivers to support OS installation using the Dell Lifecycle Controller",
      "revision_history": "N/A"
    },
    {
      "id": "55ebbc2d26cc3a26e3a06a48bf1966a572a57c5a3db7d4143265012be561d566",
      "name": "Broadcom 5719 Network Device Firmware (Industry) 23.8",
      "version": "238.1.171.0",
      "release_id": "95X28",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-08-06T19:13:37Z",
      "released": "2026-08-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14870053M/1/Network_Firmware_95X28_WN64_238.1.171.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=95X28",
      "size": 22933696,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for Broadcom NetXtreme devices.   This release should be used with the Broadcom 23.8 device drivers. Note: This firmware requires a cold reboot after installation."
    },
    {
      "id": "2fc9c4c2f6fba1fa1e47b6800081e8eb2ac2fa010c4276388723f045c8be6dfa",
      "name": "Dell EMC PowerEdge Express Flash NVMe AGN RI U.2 Gen5 Maintenance Firmware Release",
      "version": "1.3.0",
      "release_id": "HXTKM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-07-30T19:54:43Z",
      "released": "2026-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14844032M/1/Express-Flash-PCIe-SSD_Firmware_HXTKM_WN64_1.3.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HXTKM",
      "size": 32792912,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash NVMe AGN RI U.2 Gen5 Maintenance Firmware Release",
      "revision_history": "Fixes:\n1.  Sideband not accessible in panic state.\n2.  Fix to allow CR or SRIS at every PERST.\n3.  Write timeout observed during Sanitize with Block Erase.\n4.  Download/Activate doesn't complete when coupled with heavy sideband traffic.\n5.  Incorrect reference clock mode reporting after FLR.\n6.  Write command timeout due to garbage collection when out of free blocks.\n7.  Get/Set Features for OCP specific FID C4h successful for non-TCG configs.\n8.  Incorrect Response To Namespace Management Command Over MI.\n9.  PEC Error in NVMe Basic Management Command response.\n10. Resolved an SPDM attestation issue.\n\n\nEnhancements:\n\n1.  Use static endurance estimate: check the endurance estimate field of 09/C0 logpage.\n2.  Additional support added for firmware update for Dell PERC 12 and 13 controllers.\n3.  Support for 4K+8 format added.\n\nNote: Version 1.3.0 of PM1743/45 firmware is version locked due to the addition of the 4K+8 format option. Drives upgraded to 1.3.0 cannot be downgraded to previous versions of firmware."
    },
    {
      "id": "64c3b0521b620435ff6f16d6e050214f67b7fbe7f3a70d5205394e41833db3a9",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.8",
      "version": "23.81.0",
      "release_id": "RNT70",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:51:28Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843705M/1/Network_Driver_RNT70_WN64_23.81.0_238.1.170.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RNT70",
      "size": 14747512,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "10672d2ab31a63d746e4248394081f82de0310aaa1faf5e4c38a5ecc63db8f5e",
      "name": "Broadcom 57608 Network Device Firmware (Dell) 23.8",
      "version": "38.11.70.00",
      "release_id": "D64KH",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-30T17:47:40Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843647M/2/Network_Firmware_D64KH_WN64_38.11.70.00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D64KH",
      "size": 23555464,
      "reboot_required": false,
      "description": "This release provides updated network controller firmware for the Broadcom NetXtreme-E devices.   This release should be used with the Broadcom NetXtreme-E 23.8 device drivers.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "e383c232a59d867730c67aff93fece1f8bb4e33d1f8f1d0795276821d80c6740",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.8 update.",
      "version": "38.11.70.00",
      "release_id": "X9DJG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:44:02Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843656M/2/Network_Driver_X9DJG_WN64_38.11.70.00_238.1.170.0_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9DJG",
      "size": 17265544,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "4d3ed52177faa94e183a6c75e4cee8e3175a89321e6590c16562a9acd2cbb45b",
      "name": "Intel NIC Drivers, Release Version 31.2, for Windows 64-bit Operating Systems",
      "version": "31.2",
      "release_id": "TDVN6",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-23T14:09:08Z",
      "released": "2026-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14817155M/1/Network_Driver_TDVN6_WN64_31.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TDVN6",
      "size": 22841272,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel (R) NIC Drivers on Windows Server 2022, and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "See readme.txt and release notes for more information."
    },
    {
      "id": "bec783224af57063f49484de0cde7d424b3809ef473f1b1cd3002b35c9429484",
      "name": "Intel NIC Firmware Update Package release 31.2 for Intel E610-based Adapters",
      "version": "31.2.0.3",
      "release_id": "D2PJV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-23T14:02:23Z",
      "released": "2026-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14817111M/1/Network_Firmware_D2PJV_WN64_31.2.0.3_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D2PJV",
      "size": 35417392,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel (R) NIC firmware on Intel (R) E610-based adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "See release notes file for more information."
    },
    {
      "id": "4e263745edf43130b0f93dd2ab8d1b2b55532e78874d690ca1762e663eefdb30",
      "name": "Intel NIC Firmware Release 31.2 for Intel E835 Adapters",
      "version": "31.2.0.3",
      "release_id": "FXWH4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-23T13:37:40Z",
      "released": "2026-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14817010M/1/Network_Firmware_FXWH4_WN64_31.2.0.3_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FXWH4",
      "size": 54722688,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Release 31.2 on Intel E835 Adapters",
      "revision_history": "See release notes file for more information"
    },
    {
      "id": "492049c71238d8dc5085ef752d7dcd9406905f904a0c918da2e6cc862de1b52e",
      "name": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release",
      "version": "1.1.0",
      "release_id": "5DFM6",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-14T16:13:13Z",
      "released": "2026-07-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14775033M/1/Express-Flash-PCIe-SSD_Firmware_5DFM6_WN64_1.1.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5DFM6",
      "size": 38571336,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release"
    },
    {
      "id": "7cd17db5182581a2ca4292a1bd1ac4ec2b81e01a3f9e0eebb710ac61b5577aab",
      "name": "Dell EMC PowerEdge Express Flash NVMe AGN RI E3s Gen5 Maintenance Firmware Release",
      "version": "1.3.0",
      "release_id": "HN6NV",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-11T13:52:58Z",
      "released": "2026-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14763918M/1/Express-Flash-PCIe-SSD_Firmware_HN6NV_WN64_1.3.0_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN6NV",
      "size": 35704848,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash NVMe AGN RI E3s Gen5 Maintenance Firmware Release",
      "revision_history": "PLACEHOLDER\n\nNOTE: FIRMWARE 1.2.1 IS LOCKED - NO DOWN-REV POSSIBLE AFTER UPGRADE."
    },
    {
      "id": "371761514b991a27aba7ca4ab6d1d123ee789daed20e8d38b9d7e35bb6aa0055",
      "name": "Dell BM1743 NVME VRI U.2 GEN4 ISE Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "PJJF1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-06-19T00:18:32Z",
      "released": "2026-05-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14684766M/1/Express-Flash-PCIe-SSD_Firmware_PJJF1_WN64_1.2.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PJJF1",
      "size": 29641184,
      "reboot_required": false,
      "description": "Dell BM1743 NVME VRI U.2 GEN4 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n1. Improved PEL logging across power cycles.\n2. Improved NVMe-MI command handling.\n3. Improved critical error messages for OCP 2.0.\n\n\nEnhancements:\n1. Added 4K+8 LBA format capability."
    },
    {
      "id": "a580760baeeb84608afd5f181fbeb55a18f234396f7b71c2e9803b011bcbd2db",
      "name": "Dell BM1743 NVMe VRI E3.S Gen5 ISE Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "TRP69",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-06-12T20:09:53Z",
      "released": "2026-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14661021M/1/Express-Flash-PCIe-SSD_Firmware_TRP69_WN64_1.2.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TRP69",
      "size": 29641288,
      "reboot_required": false,
      "description": "Dell BM1743 NVMe VRI E3.S Gen5 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n1. Improved PEL logging across power cycles.\n2. Improved NVMe-MI command handling.\n3. Improved critical error messages for OCP 2.0.\n\n\nEnhancements:\n1. Added 4K+8 LBA format capability.\n \nNote: with the addition of the 4K+8 format capability, the firmware is locked to prevent downgrade to earlier versions of drive firmware."
    },
    {
      "id": "114a5ffb50ea56f3f130e6716fa5a9765323094f10d2a9da7d1286262553165b",
      "name": "Windows drivers for Marvell QLogic Fibre Channel adapters",
      "version": "37.15.05",
      "release_id": "XNTFF",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-06-06T05:26:27Z",
      "released": "2026-06-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14633058M/1/Network_Driver_XNTFF_WN64_37.15.05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XNTFF",
      "size": 28365248,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Update Package with Windows Drivers for Marvell adapters."
    },
    {
      "id": "be2552182a26eb88759d7217cc5aefc2cd96994a7322cfad3004048d11f48723",
      "name": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "version": "1.0.2",
      "release_id": "HN0CY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-19T21:48:29Z",
      "released": "2026-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568517M/1/Express-Flash-PCIe-SSD_Firmware_HN0CY_WN64_1.0.2_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN0CY",
      "size": 29331112,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "revision_history": "Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software)."
    },
    {
      "id": "f0477d83411396c5aa41dc093b6f87c193db3f8a49b4276a1d829a96500bfa3e",
      "name": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.2",
      "release_id": "17R29",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-05-12T10:07:15Z",
      "released": "2026-05-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14538090M/1/Express-Flash-PCIe-SSD_Firmware_17R29_WN64_2.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17R29",
      "size": 27203048,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Upon detecting SMBDAT is stuck in low state, a bus clear is performed to release the low state.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "78c2385f78e01efa51a8798695530f7a9d445ab7b40872bfb2d691b7e9e3b663",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.5",
      "release_id": "KRHCN",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-05-06T15:41:31Z",
      "released": "2026-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14515537M/1/Express-Flash-PCIe-SSD_Firmware_KRHCN_WN64_2.0.5_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KRHCN",
      "size": 27415688,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release"
    },
    {
      "id": "60553b31a0c7840eea26725f7b5326f9b56066af9311d5db5722d384d7880959",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "version": "3.0.6",
      "release_id": "7H42K",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-05-06T15:25:06Z",
      "released": "2026-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14515495M/1/Express-Flash-PCIe-SSD_Firmware_7H42K_WN64_3.0.6_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7H42K",
      "size": 27628736,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release"
    },
    {
      "id": "4e726e0bca858d9f0829ea634285766edd9fc3c3e1c09e811dcbaf07d090cfdf",
      "name": "Emulex Fibre Channel Adapter Firmware.",
      "version": "03.10.16",
      "release_id": "D3TRJ",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-05-05T17:57:05Z",
      "released": "2026-05-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14510483M/2/Fibre-Channel_Firmware_D3TRJ_WN64_03.10.16_A00-00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D3TRJ",
      "size": 29614808,
      "reboot_required": false,
      "description": "Dell Update Package for updating firmware on the Emulex Fibre Channel adapters"
    },
    {
      "id": "9908629a3c6dc68fa7bd50152775a1b55d88d11e66dbd615cc0ee12ee6f32e5c",
      "name": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "HJ15N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-07T10:29:04Z",
      "released": "2025-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14393389M/1/Express-Flash-PCIe-SSD_Firmware_HJ15N_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HJ15N",
      "size": 28267144,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "revision_history": "Fixes:\nN/A - Initial Release\n\nEnhancements:\nN/A - Initial Release"
    },
    {
      "id": "dbe132a6b0df599c1d5b32cd935918b9c403598fa5b1f6bbd1c22f3d4d65ab80",
      "name": "Dell Express Flash NVMe PCIe SSD CD9P ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "33P3K",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-07T09:35:32Z",
      "released": "2025-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14393073M/1/Express-Flash-PCIe-SSD_Firmware_33P3K_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=33P3K",
      "size": 28263024,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD9P ISE Firmware Release",
      "revision_history": "Fixes:\nN/A - Initial Release\n\nEnhancements:\nN/A - Initial Release"
    },
    {
      "id": "f7de63ece5daeac08267a48d8bc14fe3582ec54363070acb789f8ff1b32bd6df",
      "name": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "version": "2.0.5",
      "release_id": "34VN7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-18T15:31:12Z",
      "released": "2026-02-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14320085M/1/Express-Flash-PCIe-SSD_Firmware_34VN7_WN64_2.0.5_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=34VN7",
      "size": 27738144,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "revision_history": "N/A"
    },
    {
      "id": "dcbacd995c2a5a32379d174df93ed1431e6552d5a2d2ef0e098973eab0e859ff",
      "name": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release",
      "version": "1.7.0",
      "release_id": "D6RJK",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-10T13:43:02Z",
      "released": "2026-03-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14284736M/1/Express-Flash-PCIe-SSD_Firmware_D6RJK_WN64_1.7.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D6RJK",
      "size": 26508840,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release"
    },
    {
      "id": "832f358867a87dbab42fc379e286da1d8bd7b8fd87d614862be22df1da90058d",
      "name": "Hynix SE5130 DG02 Firmware for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N",
      "version": "DG02",
      "release_id": "17C3M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-03-09T14:43:52Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14279570M/1/Serial-ATA_Firmware_17C3M_WN64_DG02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17C3M",
      "size": 25675424,
      "reboot_required": true,
      "description": "This is the initial firmware release of HYNIX, SE5130, DG02 for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N.",
      "revision_history": "Fixes:\n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "6f7d5c7f6d63f599e813ae769d317937b21ce335a6a1b6a3030a62ea3135312d",
      "name": "Emulex Fibre Channel Adapter Drivers and Software Application for Windows.",
      "version": "12.34.10",
      "release_id": "8XGGG",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-03-05T07:21:25Z",
      "released": "2026-01-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14069762M/3/Fibre-Channel_Driver_8XGGG_WN64_12.34.10_A00-00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8XGGG",
      "size": 20071584,
      "reboot_required": true,
      "description": "Emulex Fibre Channel Adapter software.",
      "revision_history": "Fixes:\n\nEnhancements:\n- Enable PLDM Monitoring and Control support for ECD adapters LancerG6, Prism \u0026 Prism+ adapters."
    },
    {
      "id": "2576d421636e87b519086721087196201ac74ebd37755dce4f70eb579e503d8d",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release Maintenance Firmware",
      "version": "1.3.1",
      "release_id": "N78NP",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-03T19:47:31Z",
      "released": "2026-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14259015M/1/Express-Flash-PCIe-SSD_Firmware_N78NP_WN64_1.3.1_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N78NP",
      "size": 27170488,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release - Maintenance Firmware",
      "revision_history": "Fixes:  \n\n1. Improved the firmware to ensure internal PCIe register access is done according to the specification.\n2. Updated the firmware to add SCL detection/protection\n3. Improved firmware to detect the noise on power rail.\n4. Improved firmware to add detection/protection for incomplete Host-Initiated Data Transfer\n5. Improved firmware to add detection/protection for drive Initialization with Poor PCIe Signal Integrity\n6. Improved firmware to add detection and initiate rest/recovery operation to the power management controller upon power on.\n7. Updated the firmware to prevent the deadlock scenario while extended Host Idle Time (no SSD device I/O)\n8. Updated the firmware to Enable PCIe relaxed ordering\n\nEnhancements:  \nN/A"
    },
    {
      "id": "ec4fb21f0268cf08e8191dc8cd203fe8db5ec60b50d3e6777df0ea0551d904e5",
      "name": "Passive Backplane Firmware for 17th Generation PowerEdge 2U Servers",
      "version": "1.92",
      "release_id": "7P6P5",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-01-21T05:19:28Z",
      "released": "2025-11-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13878618M/2/Firmware_7P6P5_WN64_1.92_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7P6P5",
      "size": 20027232,
      "reboot_required": false,
      "description": "Passive Backplane Firmware for 17th Generation PowerEdge 2U Servers",
      "revision_history": "Firmware 1.92\n\nFixes - Increased I2C drive signal strength\n\nFirmware 1.90\n\nFixes:  Added additional margin to an I2C signal"
    },
    {
      "id": "58e394bb0219f32769b3c7c4911b1e094710048d3d16d092fe19ba0c8ded1e36",
      "name": "Dell 64 Bit uEFI Diagnostics, version 4303",
      "version": "4303A52",
      "release_id": "94KRT",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-01-14T21:20:10Z",
      "released": "2025-11-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14086682M/1/Diagnostics_Application_94KRT_WN64_4303A52_4303.52.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=94KRT",
      "size": 19092400,
      "reboot_required": false,
      "description": "Dell Diagnostics is designed to verify the proper operation of the hardware installed in your system outside of a high-level operating system environment. The files in this group can be used to update these diagnostics on a system with a Lifecycle Controller.",
      "revision_history": "This release contains minor bug fixes and enhancements."
    },
    {
      "id": "11627fb16dae8be6533ae44611508823df7dfc7d630b3da2e026012a1e143926",
      "name": "Dell Express Flash NVMe PCIe SSD 7600 U.2 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "VJXKC",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-09T04:07:55Z",
      "released": "2026-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14057449M/1/Express-Flash-PCIe-SSD_Firmware_VJXKC_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJXKC",
      "size": 30405520,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7600 U.2 ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any Linux OS. Either use Windows, or iDRAC for FW update. - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "30ad8ee9b868ed58051f9fcf99c4067e24ac3d2af9e5559ce2b034dae5e200c5",
      "name": "Dell Express Flash NVMe PE1010 E3.S ISE PCIe SSD Firmware Release",
      "version": "1.1.0",
      "release_id": "0930W",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-12-16T16:22:16Z",
      "released": "2025-12-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13990053M/1/Express-Flash-PCIe-SSD_Firmware_0930W_WN64_1.1.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0930W",
      "size": 32600104,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PE1010 E3.S ISE PCIe SSD Firmware Release"
    },
    {
      "id": "932eaa01f70ae0a4fa2d737c2e76e05c79bbfabff6674d75894b144a2ac7a439",
      "name": "Windows drivers for Marvell QLogic Fibre Channel adapters",
      "version": "37.10.04",
      "release_id": "RF21G",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2025-12-03T19:40:58Z",
      "released": "2025-12-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13940215M/1/Network_Driver_RF21G_WN64_37.10.04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RF21G",
      "size": 30012000,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Update Package with Windows Drivers for Marvell adapters."
    },
    {
      "id": "dbdfbff4fda3b33a0f47c4f2c9593f17f3ce0e05b9698b3ff06a66b44465d1ae",
      "name": "Hynix SE5110 ISE RI DZ04 Firmware for model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N",
      "version": "DZ04",
      "release_id": "HFTMG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-11-12T10:51:19Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13855285M/1/Serial-ATA_Firmware_HFTMG_WN64_DZ04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HFTMG",
      "size": 26870384,
      "reboot_required": true,
      "description": "This release contains initial firmware DZ04 for Hynix SE5110 ISE. Model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N.",
      "revision_history": "Fixes: \n\nFix1: Add a sequence to clear the \"\"health monitoring done bit\"\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while."
    },
    {
      "id": "7de3be6d079f697d4b19a4321005a1ef5f9aa1d1736c01661d84c10e7b3bf98d",
      "name": "BHS GNR/SRF Chipset Driver",
      "version": "10.1.19928.8615",
      "release_id": "WJ6KV",
      "category": "Chipset",
      "category_slug": "chipset",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-11-04T06:16:42Z",
      "released": "2025-08-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13327825M/4/Chipset_Driver_WJ6KV_WN64_10.1.19928.8615_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WJ6KV",
      "size": 17212448,
      "reboot_required": true,
      "description": "BHS GNR/SRF Driver 10.1.19928.8615",
      "revision_history": "BHS GNR/SRF Driver 10.1.19928.8615"
    },
    {
      "id": "908554b39cd6cc74d406096bb6698613599ce965460e1255594c8732076652b1",
      "name": "Dell PowerEdge 17G (\u0026 17G-derived systems) Trusted Platform Module 2.0 Firmware 7.2.4.1",
      "version": "7.2.4.1",
      "release_id": "0DT1G",
      "category": "Security",
      "category_slug": "security",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-10-23T17:36:25Z",
      "released": "2025-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13658502M/2/Security_Firmware_0DT1G_WN64_7.2.4.1_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0DT1G",
      "size": 22232840,
      "reboot_required": true,
      "description": "WARNING: TPM Firmware CANNOT BE DOWNGRADED.\n\niDRAC9 6.x or later is required\n\nBIOS version 1.0 or later"
    },
    {
      "id": "267f8cd8a352f89da1acbd9345d7d2ba813e2e31058d15e8bc2ac6cbce26034e",
      "name": "SAS Expander Backplane Firmware for 17th Generation PowerEdge Servers",
      "version": "1.22",
      "release_id": "5PC3C",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-10-21T15:47:58Z",
      "released": "2025-10-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13767157M/1/Firmware_5PC3C_WN64_1.22_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5PC3C",
      "size": 21634272,
      "reboot_required": true,
      "description": "SAS Expander Backplane Firmware for 17th Generation PowerEdge Servers"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "b884e9c04bd0fc93aaeb396f28a92c5b33b2aa819cdca256e448a67508c355fa",
      "name": "CXL Memory Expansion AIC Firmware Package",
      "version": "04.006.007.01R01",
      "release_id": "0NMPN",
      "category": "Memory",
      "category_slug": "memory",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-10-05T18:20:13Z",
      "released": "2025-10-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13704251M/1/Memory_Firmware_0NMPN_WN64_04.006.007.01R01_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0NMPN",
      "size": 17858952,
      "reboot_required": true,
      "description": "CXL Memory Expansion AIC Firmware Package",
      "revision_history": "CXL Memory Expansion AIC Firmware Package DECFY2026 -\nfull 96GB and 128GB mixed vendor RDIMM support FW  04.006.007.01R01 for A00/X31/X30/X21  only \n\n Fixed a buffer overrun exposed by reception of PLDM messages larger than 0x400 bytes. The issue would appear as PLDM Stack Overflow"
    },
    {
      "id": "03de1d08414a2b511614268e4a3d7ddf38fb318e34a27f7dec7fcf35c69497f2",
      "name": "Dell Express Flash NVMe PCIe SSD CM6 FIPS Maintenance Firmware Release",
      "version": "3.1.7",
      "release_id": "WJD95",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-10T05:56:19Z",
      "released": "2024-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11856439M/3/Express-Flash-PCIe-SSD_Firmware_WJD95_WN64_3.1.7_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WJD95",
      "size": 28731088,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM6 FIPS Firmware Maintenance Release",
      "revision_history": "N/A"
    },
    {
      "id": "c4c5c4afb659e69d45970617efece6b90c21784b7a020a12362d6678bfaa00a5",
      "name": "Mellanox ConnectX-6 LX Ethernet Adapter Firmware",
      "version": "26.44.10.36",
      "release_id": "K65HP",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-09-03T13:46:59Z",
      "released": "2025-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13035712M/2/Network_Firmware_K65HP_WN64_26.44.10.36_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K65HP",
      "size": 47456864,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-6 LX Adapters"
    },
    {
      "id": "c4bf141c6378349d3febc74b35f5a3024900e88e5afeb3a1a67d0c554248998e",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.1 update.",
      "version": "23.11.16.21",
      "release_id": "8YWJY",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-20T03:19:10Z",
      "released": "2024-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12155596M/4/Network_Driver_8YWJY_WN64_23.11.16.21_231.1.162.1_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8YWJY",
      "size": 14278288,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- Stop 0x133 blue screen on Windows Azure Stack HCI.\n\nEnhancements:\n- none."
    },
    {
      "id": "adf6531f24e2ae352c78eeac43153975409d38fdb931e37d3b6fff2b28109137",
      "name": "Dell EMC PowerEdge Express Flash P5336 Firmware Release",
      "version": "1.4.0",
      "release_id": "G34T2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-08-19T16:39:48Z",
      "released": "2025-08-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13526478M/1/Express-Flash-PCIe-SSD_Firmware_G34T2_WN64_1.4.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G34T2",
      "size": 27989976,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash P5336 Firmware Release"
    },
    {
      "id": "41d8ddf307b4ef32924e88af9618acf8165484bb258955e0c6381fffd74cec21",
      "name": "Seagate SBTA for Skybolt ServoBP program for model number(s) CL2400MM0149",
      "version": "SBTA",
      "release_id": "HH6J1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:02:18Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12677112M/2/SAS-Drive_Firmware_HH6J1_WN64_SBTA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HH6J1",
      "size": 23874432,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512n ISE. Model Number CL2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "4c6ed6166ab2e1a3e699af648e5457cd81edd18f87e2beea7561f7262fa1fa6d",
      "name": "Seagate SBSA for Skybolt ServoBP program for model number(s) BL2400MM0159",
      "version": "SBSA",
      "release_id": "00P56",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:22:58Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676520M/2/SAS-Drive_Firmware_00P56_WN64_SBSA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=00P56",
      "size": 23874416,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512e ISE.  Model Number BL2400MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "d7118a4011a988e2e951915d1cc298925ca524ddf11d30cbbcda0b4011e70320",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.4.0",
      "release_id": "TVCWT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-07-11T04:31:50Z",
      "released": "2025-07-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13369867M/1/Express-Flash-PCIe-SSD_Firmware_TVCWT_WN64_1.4.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TVCWT",
      "size": 29064896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo be added"
    },
    {
      "id": "3d43b16d899574bcaaf624d69349e485c2b6de77f10e32ee06016cfe013710e8",
      "name": "This release contains firmware version HL56 for supplier model number(s) MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "version": "HL56",
      "release_id": "NF72T",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-06-24T17:56:25Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12607145M/2/Serial-ATA_Firmware_NF72T_WN64_HL56_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NF72T",
      "size": 25020384,
      "reboot_required": false,
      "description": "This release contains firmware version HL56 for supplier model number(s)MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "revision_history": "Fixes: \n\n- Disabled Send / Receive FPDMA for QTRIM commands\n- Disabled NCQ Non-Data commands\n- Addressed PLP Timeout / Error Mode by correcting LPage Handles hash algorithm\n- Improved Unmap policy during Sanitize\n- Altered Protective Reclaim (PR) operation to better manange hot-spot reads"
    },
    {
      "id": "ecea33696153990ad446eddf64bc3b31180d12bdb42af975eaf0ec0d89954e53",
      "name": "Samsung HK56 FW for PM897a SATA drive program for model number(s) MZ7L3480HELTAD3, MZ7L3960HELAAD3, MZ7L31T9HENAAD3, MZ7L33T8HENAAD3",
      "version": "HK56",
      "release_id": "KHC8M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:55:37Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12607553M/2/Serial-ATA_Firmware_KHC8M_WN64_HK56_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHC8M",
      "size": 25015744,
      "reboot_required": false,
      "description": "This release contains firmware version HL56 for supplier model number(s)MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "revision_history": "Fixes: \n\n- Disabled Send / Receive FPDMA for QTRIM commands\n- Disabled NCQ Non-Data commands\n- Addressed PLP Timeout / Error Mode by correcting LPage Handles hash algorithm\n- Improved Unmap policy during Sanitize\n- Altered Protective Reclaim (PR) operation to better manange hot-spot reads"
    },
    {
      "id": "3ba243687a1eef86fefe2f16237159b1933e93d3275f272b28076d00a05ae847",
      "name": "Samsung PM897 SATA SSDs for HH62 firmware for models MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "version": "HH62",
      "release_id": "Y4WVW",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:54:57Z",
      "released": "2025-01-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12519999M/3/Serial-ATA_Firmware_Y4WVW_WN64_HH62_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=Y4WVW",
      "size": 25286320,
      "reboot_required": false,
      "description": "This release contains firmware version Samsung HH62 for model number(s) MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "revision_history": "Fixes: \n- Enhanced Reclaim Policy and reduced COMRST to 1 sec. to address PDL issue\n- Enhanced PLP/SNOR logging, to improve debuggability"
    },
    {
      "id": "59399b6ce0f13bd5649446151ad7d9a072c6d8c70f4a2f7abe335ef870bbace4",
      "name": "Dell Express Flash NVMe PCIe SSD 6500 U.2 ISE Firmware Release",
      "version": "1.1.0",
      "release_id": "NRKF4",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T07:30:48Z",
      "released": "2024-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12096577M/2/Express-Flash-PCIe-SSD_Firmware_NRKF4_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NRKF4",
      "size": 29254888,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 6500 U.2 ISE Firmware Release",
      "revision_history": "Fixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "94586f99bddb6d07e51ebf78479fa5de5fb353777dec7e7bb0b73c704b3c21bf",
      "name": "Dell Datacenter NVME RI AGN ISE",
      "version": "1.1.1",
      "release_id": "XMFKX",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:50:32Z",
      "released": "2024-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12037085M/2/Express-Flash-PCIe-SSD_Firmware_XMFKX_WN64_1.1.1_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XMFKX",
      "size": 30415680,
      "reboot_required": false,
      "description": "Dell Datacenter NVME RI AGN ISE",
      "revision_history": "Fixes:\n\n1. Updated DUP framework for 17G server platforms."
    },
    {
      "id": "7b5443856ba19be3fec98045af7c451979d66ce96d52fa3076856936318d3249",
      "name": "Dell Datacenter NVMe RI AG ISE",
      "version": "1.1.0",
      "release_id": "TDGKY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-06-20T11:09:41Z",
      "released": "2024-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12324309M/2/Express-Flash-PCIe-SSD_Firmware_TDGKY_WN64_1.1.0_A02_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TDGKY",
      "size": 31845152,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE",
      "revision_history": "Fixes:\n\nEnhancements:\n\n1. Implementation of the latest Eye Opening Measurement specfication (TP4119a).\n2. Enable support for Eye Opening Measurement (PCLMT) Tool version 3.2.7."
    },
    {
      "id": "72edf6a3bd3e7561ff46a85ae83b2753b40bcd7368e4884558a1de18497c0740",
      "name": "Dell Express Flash NVMe PCIe SSD CD8 U.2 OPAL Firmware Maintenance Release",
      "version": "1.0.1",
      "release_id": "11TRD",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T10:21:01Z",
      "released": "2025-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12428385M/2/Express-Flash-PCIe-SSD_Firmware_11TRD_WN64_1.0.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=11TRD",
      "size": 29787784,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8 U.2 OPAL Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. For PCI Information such as PCI Vendor ID other than BDF, FW also keeps their value. So, fixed to respond the value directly from FW instead of getting them from HW.\n2. Instead of clearing the Abort flag at the beginning of the response data retransfer processing task, modify it to clear the Abort flag when data transfer after retransfer becomes possible.\n3. Fix the bug that write index of SMBus ring buffer was out of sync.\n4. Max payload size is immediately reflected in the internal register when the value is changed.\n5. Wait for transition from Recovery when VDM packet forwarding is completed.\n6. Fixed to resume Write process after NAND Timeout recovery process.\n7. Set OACS bit10 to 1 to remove support of Lockdown on the in-band interface.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "ebab35593b8ac0c513d254ce873044e26b14b392f0c784345e74096a941ff3cd",
      "name": "Mellanox Windows 64-bit Server OS drivers for Mellanox ConnectX-6 \u0026 ConnectX-7 Ethernet adapters",
      "version": "24.10.01",
      "release_id": "769K2",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-06-20T09:31:40Z",
      "released": "2025-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12371906M/3/Network_Driver_769K2_WN64_24.10.01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=769K2",
      "size": 160938232,
      "reboot_required": false,
      "description": "This package provides the Windows 64-bit drivers for Mellanox ConnectX-6 \u0026 Connect-X7 Ethernet Adapters and is supported on Dell EMC PowerEdge servers with the following operating systems: Windows Server 2022, Windows Server 2025"
    },
    {
      "id": "6dda8130349061033340f5294301d0efa9dd01c0c4e44bf4d0cc1f18300d0de3",
      "name": "Dell Firmware Update Package for Marvell/QLogic 2690 series Fibre Channel adapters",
      "version": "17.05.10",
      "release_id": "MTCFH",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-11T18:00:26Z",
      "released": "2025-06-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13240371M/1/Fibre-Channel_Firmware_MTCFH_WN64_17.05.10_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MTCFH",
      "size": 21507440,
      "reboot_required": true,
      "description": "This software bundle includes a Dell Firmware Update Package for Marvell/QLogic 2690 and 2740 series Fibre Channel adapters."
    },
    {
      "id": "305da8692e0ed80a3fb5e443af140886ee68c1a0598d38a02210ad4910079462",
      "name": "Mellanox ConnectX-6 DX Ethernet Adapter Firmware",
      "version": "22.44.10.36",
      "release_id": "975XG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-06-09T19:37:26Z",
      "released": "2025-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13036712M/2/Network_Firmware_975XG_WN64_22.44.10.36_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=975XG",
      "size": 49305096,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-6 DX Adapters"
    },
    {
      "id": "1c33160daccea25862c0868752c3f6de3029d3fbed1f0c2ff3803d0ef3b0753d",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 E3.S FIPS Firmware Maintenance Release",
      "version": "3.0.2",
      "release_id": "VN92N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-23T17:03:52Z",
      "released": "2025-04-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13157817M/1/Express-Flash-PCIe-SSD_Firmware_VN92N_WN64_3.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VN92N",
      "size": 29958320,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 E3.S FIPS Firmware Maintenance Release",
      "revision_history": "Fixes:  \nTo be Added."
    },
    {
      "id": "e1c9baab746a197329509da4e36ba1d2db44f75dc2a71e34e37910ece96bb56b",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 E3.S ISE Firmware Maintenance Release",
      "version": "2.0.2",
      "release_id": "N43V2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-23T17:03:30Z",
      "released": "2025-04-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13157812M/1/Express-Flash-PCIe-SSD_Firmware_N43V2_WN64_2.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N43V2",
      "size": 29819040,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo Be added"
    },
    {
      "id": "0ec4a72763c6f617356a0e2ee5e7e3aad191109ec75324d8f0202fff4986bbaf",
      "name": "Mellanox Windows 64-bit Server OS drivers for Mellanox ConnectX-4 Lx, ConnectX-5, ConnectX-6 and ConnectX-7 Ethernet adapters",
      "version": "25.1",
      "release_id": "3G71F",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-04-23T17:03:08Z",
      "released": "2025-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13036121M/1/Network_Driver_3G71F_WN64_25.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3G71F",
      "size": 213767824,
      "reboot_required": false,
      "description": "This package provides the Windows 64-bit drivers for Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, and ConnectX-7 Ethernet Adapters and is supported on Dell EMC PowerEdge servers with the following operating systems: Windows Server 2019 and Windows Server 2022"
    },
    {
      "id": "851192910676f62564014c1ffe71bea150f0ccd442fae8c4d0e4d63fda7efb42",
      "name": "Toshiba EF09 for model number(s) AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY",
      "version": "EF09",
      "release_id": "J11N2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T10:54:37Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12128055M/2/SAS-Drive_Firmware_J11N2_WN64_EF09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J11N2",
      "size": 23842608,
      "reboot_required": false,
      "description": "This release contains firmware version EF09 for Toshiba drives. Vendor model numbers AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY.\nRevert high fly write detection methodology back to process used in previous EF06 Firmware",
      "revision_history": "Revert high fly write detection methodology back to process used in previous EF06 Firmware."
    },
    {
      "id": "2142620e2c8d50ab1cb18380fc3fde53962851f2adaa2310acaf43d8362b33f5",
      "name": "Hynix 1.2.1 FW for PE9010 NVMe drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "version": "1.2.1",
      "release_id": "8X8YR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-08T07:02:51Z",
      "released": "2025-04-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12965378M/1/Express-Flash-PCIe-SSD_Firmware_8X8YR_WN64_1.2.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8X8YR",
      "size": 23487200,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.2.0 for Hynix PE9010 NVMe SSD drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, and HFS480GDJ8X167N.",
      "revision_history": "Fixes:\n\nFixes the DCTm layer that was introduced in 1.2.0 '  Pause MCTP for Error responsing Admin command (ex. Invalid Opcode, Prohibited Opcode..) when CIAP==1.\nChanged not to block MI command in reset service blocker.\nFix to treat FTL fail of, unattached address area, during DST as DSTR:6\nFixed smbus interrupt error case\nAdd NSSR to PanicResetAction\nSet PEL for control primitive resume with invalid param for CSI\n\"First packet received in multi packet\nMCTP Control message received with same tag.\nFirst message discard, but slot state (MI context) not clear.\"\nset NSSRO bit after panic reset\nClear MI GetState ErrorState Bits managed on HADM side when MCTP Endpoint reset.\nCheck DOFST field of MI admin commands before processing.\nSmart::updateControllerBusyTime bug fix\nreset number of queues during nvme reset\nAssert occurs during SPL in Panic Recovery\nFix DELL Incorrect TLA and ADellEMCUI default values\nPCIe correctable receiver error during NSSR"
    },
    {
      "id": "8805f93f162a5e9a7282553f3a2eb98d8cfd822f43e29e41219e7f999c02fac5",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.2 update.",
      "version": "23.21.13.32",
      "release_id": "G535X",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-14T01:03:16Z",
      "released": "2025-01-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12577171M/2/Network_Driver_G535X_WN64_23.21.13.32_232.1.133.2_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G535X",
      "size": 14210264,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver."
    },
    {
      "id": "ab13ae4fdb4fa0345532494866bbbc497d0ca9dccb6790c83aa34bdfdc8dc834",
      "name": "Samsung PM893 SATA SSDs for HJ62 firmware for models MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3",
      "version": "HJ62",
      "release_id": "537XV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-12-24T13:41:29Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12519998M/1/Serial-ATA_Firmware_537XV_WN64_HJ62_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=537XV",
      "size": 13233416,
      "reboot_required": false,
      "description": "This release contains firmware version Samsung HJ62 for model number(s) MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3.",
      "revision_history": "Fixes: \n\n- Enhanced Reclaim Policy and reduced COMRST to 1 sec. to address PDL issue.\n- Enhanced PLP/SNOR logging, to improve debuggability."
    },
    {
      "id": "ef389c6bcd13e4bc8c7e55c18e9f159694d043492eb9723fd98bb19cb2c44085",
      "name": "Open Server Manager 3.0.2",
      "version": "3.0.2-g830844c66-2.14.0",
      "release_id": "3CRFC",
      "category": "BMC",
      "category_slug": "bmc",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-10-22T20:23:59Z",
      "released": "2024-10-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12245613M/1/BMC_Firmware_3CRFC_WN64_3.0.2-g830844c66-2.14.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3CRFC",
      "size": 135891504,
      "reboot_required": false,
      "description": "Open Server Manager 3.0.2",
      "revision_history": "Open Server Manager release built on OpenBMC(TM) for PowerEdge R670 and R770 CSP Edition systems that have shipped with Open Server Manager (OSM) pre-installed.\n\nFixes and Enhancements:\n\n- iDRAC Conversion\n   . Supports the conversion of OSM to iDRAC.\n\n- PSU FW Update\n   . Fixes the problems associated with PSU FW update."
    },
    {
      "id": "6dffa0fa05d98ecf5dd6f683737e3ab3d4e113f263fe4ec62004af5ecf3268e8",
      "name": "Intel NIC Family Version 23.0.0 Drivers for Windows 64-bit Operating Systems",
      "version": "23.0.0",
      "release_id": "6JHVK",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-07-19T15:27:45Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890492M/1/Network_Driver_6JHVK_WN64_23.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6JHVK",
      "size": 42776640,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "See readme.txt for more info."
    },
    {
      "id": "7be90932a9eca915194db12b4b54c6e2d1dfaf50ecc4c79c27b1761682ea45d0",
      "name": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "version": "2.5.0",
      "release_id": "4P5K1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-07-03T13:05:39Z",
      "released": "2024-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11804735M/1/Express-Flash-PCIe-SSD_Firmware_4P5K1_WN64_2.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4P5K1",
      "size": 7724464,
      "reboot_required": false,
      "description": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "revision_history": "Fixes:\n\n- FW introduces multiple fixes and enhancements."
    },
    {
      "id": "e304b4a3afc9985ef42898953bbb4c4c2209d80b9c683042b9eca3daf720a4c2",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "version": "3.1.3",
      "release_id": "JTTYW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T17:47:50Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674733M/1/Express-Flash-PCIe-SSD_Firmware_JTTYW_WN64_3.1.3_A06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTTYW",
      "size": 19213864,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "e3a57703641508d75951c269b891d60af16ef1102477a7610d5e07c6cb16ef3e",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "version": "1.1.1",
      "release_id": "28J8R",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T16:27:47Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674461M/1/Express-Flash-PCIe-SSD_Firmware_28J8R_WN64_1.1.1_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=28J8R",
      "size": 19207336,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "57c906ff5507962cafb5c3c783d13f06921a3b3fc05d0d6ba692520b4090e167",
      "name": "Seagate ST37 for model number(s) ST600MM0069 and ST1200MM0099.",
      "version": "ST37",
      "release_id": "C161G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-29T10:13:00Z",
      "released": "2023-07-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09844732M/3/SAS-Drive_Firmware_C161G_WN64_ST37_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C161G",
      "size": 13245848,
      "reboot_required": false,
      "description": "This release contains firmware version ST36 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error hapepends during a head switch with RAW enabled."
    },
    {
      "id": "9d1c1564008221f1f7a7c85b77df4c49bc728867b7bffb5361e743e9f19ed7b9",
      "name": "Seagate SBW5 for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "version": "SBW5",
      "release_id": "9KWMD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-26T11:29:43Z",
      "released": "2023-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09947108M/2/SAS-Drive_Firmware_9KWMD_WN64_SBW5_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9KWMD",
      "size": 13258560,
      "reboot_required": false,
      "description": "This release contains firmware version SBW5 Seagate for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled."
    },
    {
      "id": "6c992026ccb1034e5d76c43933dc44c2595da3c48f49b380535843c14de95847",
      "name": "Micron K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "version": "K003",
      "release_id": "RJ0WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T14:41:30Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606437M/2/Serial-ATA_Firmware_RJ0WY_WN64_K003_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJ0WY",
      "size": 12627936,
      "reboot_required": false,
      "description": "This release contains firmware version K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "revision_history": "Fixes:\n\n-Fixes to address performance."
    },
    {
      "id": "7f5691c4430c7327b0a80ce3ef83995daadc50336c7a6a3a67edf9b560b1db34",
      "name": "Micron K403 for 5400 SATA model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB",
      "version": "K403",
      "release_id": "JTW3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T06:58:14Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606566M/2/Serial-ATA_Firmware_JTW3W_WN64_K403_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTW3W",
      "size": 12364032,
      "reboot_required": false,
      "description": "This release contains firmware version K403 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB.",
      "revision_history": "Fixes:\n\n- Fixes to address performance."
    }
  ]
}
