  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r740",
  "name": "R740",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R740 Express Flash PCIe SSD Updates",
  "filter": "express-flash-pcie-ssd",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 59,
      "rss": "/r740/urgent/rss.xml",
      "api": "/api/r740/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 203,
      "rss": "/r740/recommended/rss.xml",
      "api": "/api/r740/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 68,
      "rss": "/r740/optional/rss.xml",
      "api": "/api/r740/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r740/bios/rss.xml",
      "api": "/api/r740/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/r740/chipset/rss.xml",
      "api": "/api/r740/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/r740/diagnostics/rss.xml",
      "api": "/api/r740/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r740/drivers-for-os-deployment/rss.xml",
      "api": "/api/r740/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 19,
      "rss": "/r740/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r740/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 17,
      "rss": "/r740/fibre-channel/rss.xml",
      "api": "/api/r740/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 4,
      "rss": "/r740/firmware/rss.xml",
      "api": "/api/r740/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r740/idrac/rss.xml",
      "api": "/api/r740/idrac"
    },
    {
      "slug": "memory",
      "label": "Memory",
      "count": 3,
      "rss": "/r740/memory/rss.xml",
      "api": "/api/r740/memory"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 59,
      "rss": "/r740/network/rss.xml",
      "api": "/api/r740/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 112,
      "rss": "/r740/sas-drive/rss.xml",
      "api": "/api/r740/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 9,
      "rss": "/r740/sas-non-raid/rss.xml",
      "api": "/api/r740/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 23,
      "rss": "/r740/sas-raid/rss.xml",
      "api": "/api/r740/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 74,
      "rss": "/r740/serial-ata/rss.xml",
      "api": "/api/r740/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r740/systems-management/rss.xml",
      "api": "/api/r740/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/r740/video/rss.xml",
      "api": "/api/r740/video"
    }
  ],
  "count": 19,
  "updates": [
    {
      "id": "2784cac0b8b58ea70ad630208898d6eb97e9b03ca201d3538f7cdf540045f1b2",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N",
      "version": "1.3.1",
      "release_id": "VMDWF",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:48Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652186M/3/Express-Flash-PCIe-SSD_Firmware_VMDWF_WN64_1.3.1_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VMDWF",
      "size": 28699000,
      "reboot_required": true,
      "description": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N.",
      "revision_history": "Fixes: \n\nFW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "48c5469a4a346a44cc4729143b3df57c3c9d8a12638878a02ea6a9cd86561b51",
      "name": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "version": "1.0.2",
      "release_id": "1W7Y8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-22T19:07:37Z",
      "released": "2026-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568456M/2/Express-Flash-PCIe-SSD_Firmware_1W7Y8_WN64_1.0.2_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1W7Y8",
      "size": 35321280,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected SPDM data offset used when calculating the SPDM manifest.\n2. Enhanced NVMe-MI logic.\n3. Fixed NVMe-MI message response delays; reponses to all NVMe-MI messages within a 100ms timeout period.\n4. Restrict SMBus communication to when the drive is ready to service MCTP/Basic.\n\nEnhancements:\n\n1. Enhanced MCTP processing over SMBus while SMBus is in a reset state.\n2. DUP support for ARM platforms added.\n3. DUP support updated for PERC 12 and 13."
    },
    {
      "id": "492049c71238d8dc5085ef752d7dcd9406905f904a0c918da2e6cc862de1b52e",
      "name": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release",
      "version": "1.1.0",
      "release_id": "5DFM6",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-14T16:13:13Z",
      "released": "2026-07-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14775033M/1/Express-Flash-PCIe-SSD_Firmware_5DFM6_WN64_1.1.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5DFM6",
      "size": 38571336,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release"
    },
    {
      "id": "7cd17db5182581a2ca4292a1bd1ac4ec2b81e01a3f9e0eebb710ac61b5577aab",
      "name": "Dell EMC PowerEdge Express Flash NVMe AGN RI E3s Gen5 Maintenance Firmware Release",
      "version": "1.3.0",
      "release_id": "HN6NV",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-11T13:52:58Z",
      "released": "2026-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14763918M/1/Express-Flash-PCIe-SSD_Firmware_HN6NV_WN64_1.3.0_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN6NV",
      "size": 35704848,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash NVMe AGN RI E3s Gen5 Maintenance Firmware Release",
      "revision_history": "PLACEHOLDER\n\nNOTE: FIRMWARE 1.2.1 IS LOCKED - NO DOWN-REV POSSIBLE AFTER UPGRADE."
    },
    {
      "id": "371761514b991a27aba7ca4ab6d1d123ee789daed20e8d38b9d7e35bb6aa0055",
      "name": "Dell BM1743 NVME VRI U.2 GEN4 ISE Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "PJJF1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-06-19T00:18:32Z",
      "released": "2026-05-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14684766M/1/Express-Flash-PCIe-SSD_Firmware_PJJF1_WN64_1.2.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PJJF1",
      "size": 29641184,
      "reboot_required": false,
      "description": "Dell BM1743 NVME VRI U.2 GEN4 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n1. Improved PEL logging across power cycles.\n2. Improved NVMe-MI command handling.\n3. Improved critical error messages for OCP 2.0.\n\n\nEnhancements:\n1. Added 4K+8 LBA format capability."
    },
    {
      "id": "a580760baeeb84608afd5f181fbeb55a18f234396f7b71c2e9803b011bcbd2db",
      "name": "Dell BM1743 NVMe VRI E3.S Gen5 ISE Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "TRP69",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-06-12T20:09:53Z",
      "released": "2026-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14661021M/1/Express-Flash-PCIe-SSD_Firmware_TRP69_WN64_1.2.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TRP69",
      "size": 29641288,
      "reboot_required": false,
      "description": "Dell BM1743 NVMe VRI E3.S Gen5 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n1. Improved PEL logging across power cycles.\n2. Improved NVMe-MI command handling.\n3. Improved critical error messages for OCP 2.0.\n\n\nEnhancements:\n1. Added 4K+8 LBA format capability.\n \nNote: with the addition of the 4K+8 format capability, the firmware is locked to prevent downgrade to earlier versions of drive firmware."
    },
    {
      "id": "be2552182a26eb88759d7217cc5aefc2cd96994a7322cfad3004048d11f48723",
      "name": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "version": "1.0.2",
      "release_id": "HN0CY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-19T21:48:29Z",
      "released": "2026-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568517M/1/Express-Flash-PCIe-SSD_Firmware_HN0CY_WN64_1.0.2_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN0CY",
      "size": 29331112,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "revision_history": "Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software)."
    },
    {
      "id": "60553b31a0c7840eea26725f7b5326f9b56066af9311d5db5722d384d7880959",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "version": "3.0.6",
      "release_id": "7H42K",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-05-06T15:25:06Z",
      "released": "2026-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14515495M/1/Express-Flash-PCIe-SSD_Firmware_7H42K_WN64_3.0.6_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7H42K",
      "size": 27628736,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release"
    },
    {
      "id": "dcbacd995c2a5a32379d174df93ed1431e6552d5a2d2ef0e098973eab0e859ff",
      "name": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release",
      "version": "1.7.0",
      "release_id": "D6RJK",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-10T13:43:02Z",
      "released": "2026-03-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14284736M/1/Express-Flash-PCIe-SSD_Firmware_D6RJK_WN64_1.7.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D6RJK",
      "size": 26508840,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "da85579aa702b2b4706a4585289b3365530f2b08daaa68c78b9a2fca56bcd394",
      "name": "Hynix 1.2.1 FW for PE9030 NVMEe drive program for model number HFS800GDJ8X167N",
      "version": "1.2.1",
      "release_id": "9GH86",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-08T10:44:59Z",
      "released": "2025-04-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12967278M/1/Express-Flash-PCIe-SSD_Firmware_9GH86_WN64_1.2.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9GH86",
      "size": 19658776,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.2.0 for Hynix PE9030 NVMe SSD drive program for model number HFS800GDJ8X167N",
      "revision_history": "Fixes:\n\nFixes the DCTm layer that was introduced in 1.2.'0. Pauses MCTP for Error responsing Admin command (ex. Invalid Opcode, Prohibited Opcode..) when CIAP==1.\nChanged not to block MI command in reset service blocker.\nFix to treat FTL fail of, unattached address area, during DST as DSTR:6\nFixed smbus interrupt error case\nAdd NSSR to PanicResetAction\nSet PEL for control primitive resume with invalid param for CSI\n\"First packet received in multi packet\nMCTP Control message received with same tag.\nFirst message discard, but slot state (MI context) not clear.\"\nset NSSRO bit after panic reset\nClear MI GetState ErrorState Bits managed on HADM side when MCTP Endpoint reset.\nCheck DOFST field of MI admin commands before processing.\nSmart::updateControllerBusyTime bug fix\nreset number of queues during nvme reset\nAssert occurs during SPL in Panic Recovery\nFix DELL Incorrect TLA and ADellEMCUI default values\nPCIe correctable receiver error during NSSR"
    },
    {
      "id": "2142620e2c8d50ab1cb18380fc3fde53962851f2adaa2310acaf43d8362b33f5",
      "name": "Hynix 1.2.1 FW for PE9010 NVMe drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "version": "1.2.1",
      "release_id": "8X8YR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-08T07:02:51Z",
      "released": "2025-04-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12965378M/1/Express-Flash-PCIe-SSD_Firmware_8X8YR_WN64_1.2.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8X8YR",
      "size": 23487200,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.2.0 for Hynix PE9010 NVMe SSD drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, and HFS480GDJ8X167N.",
      "revision_history": "Fixes:\n\nFixes the DCTm layer that was introduced in 1.2.0 '  Pause MCTP for Error responsing Admin command (ex. Invalid Opcode, Prohibited Opcode..) when CIAP==1.\nChanged not to block MI command in reset service blocker.\nFix to treat FTL fail of, unattached address area, during DST as DSTR:6\nFixed smbus interrupt error case\nAdd NSSR to PanicResetAction\nSet PEL for control primitive resume with invalid param for CSI\n\"First packet received in multi packet\nMCTP Control message received with same tag.\nFirst message discard, but slot state (MI context) not clear.\"\nset NSSRO bit after panic reset\nClear MI GetState ErrorState Bits managed on HADM side when MCTP Endpoint reset.\nCheck DOFST field of MI admin commands before processing.\nSmart::updateControllerBusyTime bug fix\nreset number of queues during nvme reset\nAssert occurs during SPL in Panic Recovery\nFix DELL Incorrect TLA and ADellEMCUI default values\nPCIe correctable receiver error during NSSR"
    },
    {
      "id": "6015e77f9438cdd754023cfda5871ba7de0e5e38b506d86bb975cbaaa88f5b36",
      "name": "Dell Express Flash NVMe P4500/P4600 PCIe SSD Firmware Release",
      "version": "QDV1DP17",
      "release_id": "CR0HC",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T21:34:56Z",
      "released": "2020-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06533230M/2/Express-Flash-PCIe-SSD_Firmware_CR0HC_WN64_QDV1DP17_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CR0HC",
      "size": 16645544,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe P4500/P4600 PCIe SSD Firmware Release"
    },
    {
      "id": "04c1b0629a67a3f4cb7f521f2c0e24758db57c0f75367363cf342366a3149630",
      "name": "Dell PowerEdge Express Flash Ent NVMe AGN SED Firmware Release",
      "version": "1.5.0",
      "release_id": "610WN",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:42:11Z",
      "released": "2023-12-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10871637M/2/Express-Flash-PCIe-SSD_Firmware_610WN_WN64_1.5.0_A06_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=610WN",
      "size": 21649848,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe AGN SED Firmware Release",
      "revision_history": "Fixes:\n\n1. Improved Persistent Event Log behavior.\n2. Improved management interface responsiveness VDM command handling.\n3. Improved temperature reporting.\n\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "17d32c474894380a62ddc1069b6710fa5986fac584390d91f063c236fb97aea9",
      "name": "Dell PowerEdge Express Flash Ent NVMe AGN Firmware Release",
      "version": "2.5.0",
      "release_id": "5CM3G",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:38:47Z",
      "released": "2023-12-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10871579M/3/Express-Flash-PCIe-SSD_Firmware_5CM3G_WN64_2.5.0_A06_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5CM3G",
      "size": 21646664,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. Improved Persistent Event Log behavior.\n2. Improved management interface responsiveness VDM command handling.\n3. Improved temperature reporting.\n\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "a62cf8b6040c3af38844b03634d1e0c492420b94c03ac7b4dbc5a750a5c78d19",
      "name": "Dell Express Flash NVMe PCIe SSD PM1725a Firmware Release",
      "version": "1.2.1",
      "release_id": "34C36",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-30T17:17:43Z",
      "released": "2021-02-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07036198M/3/Express-Flash-PCIe-SSD_Firmware_34C36_WN64_1.2.1_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=34C36",
      "size": 18653896,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe PCIe SSD PM1725a firmware release",
      "revision_history": "Fixes:\n1. Fixed to guarantee LOC retry Q processing within a certain time.\n2. Added one semaphore to lock the access of SFR \u0026 Applied the semaphore to all cores where we have synchronization problem\n3. Assert during VPD reads fix with FW change that resolves contention to ensure that the variable is no longer affected by the resource contention issue.  \n4. Fixed reset check in reservation bring up path to prevent initialization due to NSSR.  After this change the Reservation is retained.\n5. Disable arbitration at the beginning of NSSR so that no invalid status are sent to the host while NSSR is being processed.\n6. Applied enhanced NAND recovery algorithm to prevent read UECC error\n\nEnhancements:\nN/A"
    },
    {
      "id": "56088825928a2490073d1688903d8e778f901b211ac34920f33b72d7d3c6b33f",
      "name": "Dell Express Flash NVMe PCIe SSD PM1725b Firmware Release",
      "version": "1.2.1",
      "release_id": "JXWJW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-30T17:14:38Z",
      "released": "2020-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06652670M/2/Express-Flash-PCIe-SSD_Firmware_JXWJW_WN64_1.2.1_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JXWJW",
      "size": 18945960,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD PM1725b firmware release",
      "revision_history": "Bug Fixes:\n1. If the command is moved to LOC retry Q and it is not processed for a certain period of time(32ms), stop processing the new command and process the command of LOC retry Q\n2. The priority if given to the Format command to allow it to complete.  Hence while a format operation is going on the FW will not log unrelated commands timeout. \n3. Correct the search function to find the correct abort command used to abort another command.\n4. The FW change resolves this contention to ensure that this variable is no longer affected by the resource contention issue.  \n5. This change will bypass RO mode and allow the drive to continue normal bringup.  The internal error log file will be re-written at the next error the host is notified on.  \n6. Fixed reset check in reservation bring up path to prevent initialization due to NSSR.  After this change the Reservation is retained."
    }
  ]
}