  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r6725",
  "name": "R6725",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R6725 Serial ATA Updates",
  "filter": "serial-ata",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 17,
      "rss": "/r6725/urgent/rss.xml",
      "api": "/api/r6725/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 76,
      "rss": "/r6725/recommended/rss.xml",
      "api": "/api/r6725/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 41,
      "rss": "/r6725/optional/rss.xml",
      "api": "/api/r6725/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r6725/bios/rss.xml",
      "api": "/api/r6725/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r6725/boss/rss.xml",
      "api": "/api/r6725/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r6725/chipset/rss.xml",
      "api": "/api/r6725/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r6725/diagnostics/rss.xml",
      "api": "/api/r6725/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r6725/drivers-for-os-deployment/rss.xml",
      "api": "/api/r6725/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 38,
      "rss": "/r6725/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r6725/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 6,
      "rss": "/r6725/fibre-channel/rss.xml",
      "api": "/api/r6725/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/r6725/firmware/rss.xml",
      "api": "/api/r6725/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r6725/idrac/rss.xml",
      "api": "/api/r6725/idrac"
    },
    {
      "slug": "memory",
      "label": "Memory",
      "count": 1,
      "rss": "/r6725/memory/rss.xml",
      "api": "/api/r6725/memory"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 19,
      "rss": "/r6725/network/rss.xml",
      "api": "/api/r6725/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 24,
      "rss": "/r6725/sas-drive/rss.xml",
      "api": "/api/r6725/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 1,
      "rss": "/r6725/sas-non-raid/rss.xml",
      "api": "/api/r6725/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 9,
      "rss": "/r6725/sas-raid/rss.xml",
      "api": "/api/r6725/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/r6725/security/rss.xml",
      "api": "/api/r6725/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 26,
      "rss": "/r6725/serial-ata/rss.xml",
      "api": "/api/r6725/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r6725/systems-management/rss.xml",
      "api": "/api/r6725/systems-management"
    }
  ],
  "count": 26,
  "updates": [
    {
      "id": "03e8dec5c03adb6448e38d5f9b0b4125a9bb5df8f6d028557b2ca7607f6dc11e",
      "name": "Firmware Update for WDC London-DP SATA ISE Model Numbers WUH722420ALE600 \u0026 WUH722424ALE600.",
      "version": "YT05",
      "release_id": "TH00R",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T10:12:05Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14473938M/1/Serial-ATA_Firmware_TH00R_WN64_YT05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TH00R",
      "size": 25064600,
      "reboot_required": false,
      "description": "Firmware Update for WDC London-DP YT05 FW SATA ISE Model Numbers WUH722420ALE600 \u0026 WUH722424ALE600.",
      "revision_history": "- Fix for event when Drive hits self-initiated reset when we failed to retrieve write specs from the drive media cache.\n- Ensure model number and component ID report correctly when loading Server firmware on top of Storage firmware.\n- Fixes to improve Adjacent Track Interference handling.\n- Various other maintenance fixes and  enhancements.\n- Multiple firmware fixes to address self-initiated resets and additional maintenance updates."
    },
    {
      "id": "1649cedd050f14c96f8903133c79a26b7f90719920c7fbde0a1ff66c7d8db1b9",
      "name": "Firmware update for WDC Paris-CP SATA ISE Model Numbers: WUH722012CLE600, WUH722016CLE600",
      "version": "AT06",
      "release_id": "36JH0",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T07:23:32Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14472919M/1/Serial-ATA_Firmware_36JH0_WN64_AT06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=36JH0",
      "size": 22781784,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP AT06 FW SATA ISE Model Numbers: WUH722012CLE600, WUH722016CLE600.",
      "revision_history": "- Firmware update to ensure the 512e Dell Model string and Dell Device ID will not show correctly when Server code is loaded over Storage code.\n- FW fix to ensure Background Media Scan timer is reset correctly when Offline Data Collection is started.\n- Code updated to ensure Component ID and Model string will report correctly after firmware upload."
    },
    {
      "id": "832f358867a87dbab42fc379e286da1d8bd7b8fd87d614862be22df1da90058d",
      "name": "Hynix SE5130 DG02 Firmware for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N",
      "version": "DG02",
      "release_id": "17C3M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-03-09T14:43:52Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14279570M/1/Serial-ATA_Firmware_17C3M_WN64_DG02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17C3M",
      "size": 25675424,
      "reboot_required": true,
      "description": "This is the initial firmware release of HYNIX, SE5130, DG02 for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N.",
      "revision_history": "Fixes:\n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "109fb6b95e4f17a3406ee60a0fd9f5f182f10aecad84d73f05b068cd4eb379bb",
      "name": "Toshiba GD06 for MG08 Air SATA 4TB program for model number(s) MG08ADA400NY.",
      "version": "GD06",
      "release_id": "NK38K",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-21T16:35:13Z",
      "released": "2026-01-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14115387M/1/Serial-ATA_Firmware_NK38K_WN64_GD06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NK38K",
      "size": 22451512,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba GD06 for MG08 Air SATA 4TB program for model number(s) MG08ADA400NY",
      "revision_history": "- Adjusted the algorithm to prioritize read commands when the ratio of queued write commands is high.\n- Added log version information to the header section of the Health management log.\n- Refactored the code to add new internal functions.\n- Added firmware fix to prioritize read commands when the ratio of queued write commands is high."
    },
    {
      "id": "9fd6affe37d428e75f2e8db5e95c5ad5dd42698079c34de94e37e76eaaf4f4ba",
      "name": "Toshiba MG08AD SATA ISE drive program for GE04 FW for model number(s): MG08ADA800EY",
      "version": "GE04",
      "release_id": "2HN47",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-21T16:18:53Z",
      "released": "2026-01-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14115298M/1/Serial-ATA_Firmware_2HN47_WN64_GE04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2HN47",
      "size": 22472928,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG08AD SATA ISE.  Model number MG08ADA800EY.",
      "revision_history": "- Adjusted the algorithm to prioritize read commands when the ratio of queued write commands is high.\n- Added log version information to the header section of the Health management log.\n- Refactored the code to add new internal functions.\n- Added firmware fix to prioritize read commands when the ratio of queued write commands is high."
    },
    {
      "id": "dbdfbff4fda3b33a0f47c4f2c9593f17f3ce0e05b9698b3ff06a66b44465d1ae",
      "name": "Hynix SE5110 ISE RI DZ04 Firmware for model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N",
      "version": "DZ04",
      "release_id": "HFTMG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-11-12T10:51:19Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13855285M/1/Serial-ATA_Firmware_HFTMG_WN64_DZ04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HFTMG",
      "size": 26870384,
      "reboot_required": true,
      "description": "This release contains initial firmware DZ04 for Hynix SE5110 ISE. Model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N.",
      "revision_history": "Fixes: \n\nFix1: Add a sequence to clear the \"\"health monitoring done bit\"\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while."
    },
    {
      "id": "3735b6b54fcf04cd59cca7137654bb59c8fcdefecff53476ea296922b2fd6175",
      "name": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\nFW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.",
      "version": "PV10",
      "release_id": "8R6W6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-25T09:20:50Z",
      "released": "2025-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13676887M/1/Serial-ATA_Firmware_8R6W6_WN64_PV10_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8R6W6",
      "size": 23949896,
      "reboot_required": false,
      "description": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\n'FW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.\nIncludes FW update to add recognition of 2TB SATA capacity part number",
      "revision_history": "FW update to add Dell Part Number for newly added 2TB capacity"
    },
    {
      "id": "a532663557fe380d5eb4ab8962d7792bc9cb162b8c61ab38381f25fb5867db85",
      "name": "This release contains firmware version GC04 for Toshiba  drives. Vendor model numbers MG08ACA16TEY.",
      "version": "GC04",
      "release_id": "WTNDC",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T15:58:28Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12147089M/4/Serial-ATA_Firmware_WTNDC_WN64_GC04_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WTNDC",
      "size": 23424056,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG08 SATA ISE.  Model number MG08ACA16TEY.\nFix for a potential mis-detection of a buffer CRC error, and to include performance improvements.",
      "revision_history": "Changed the error response of read command from host-FIFO parity error to BCRC (Buffer CRC) error when host-FIFO parity error also occurred at the same time due to BCRC error during read transfer, because the main cause of the error is BCRC error.\nCorrected the SenseCode for the Download process error.\nPerformance improvements."
    },
    {
      "id": "f0c7c33f6a4f201f2f057bdb96f86911a0ec0cd66093d0e463fd502f62819caf",
      "name": "Firmware Update for EvansBP SATA ISE HDD.  Model numbers: ST12000NM002J-2TY133, ST14000NM002J-2TX133, ST16000NM002J-2TW133, ST18000NM002J-2TV133\n\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing",
      "version": "PALB",
      "release_id": "4MPD6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T15:57:45Z",
      "released": "2025-01-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12476257M/4/Serial-ATA_Firmware_4MPD6_WN64_PALB_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4MPD6",
      "size": 23564640,
      "reboot_required": false,
      "description": "This package contains firmware version PALB for Seagate drives (vendor Model numbers: ST12000NM002J-2TY133, ST14000NM002J-2TX133, ST16000NM002J-2TW133, ST18000NM002J-2TV133)",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command\n- Fix for potential assert during Write Uncorrectable testing\n- Shorten time delay before running Direct Offline Scan"
    },
    {
      "id": "45228c5635928cde92a1f46643d5a35b22ba672a72066d533bdcab54789eec75",
      "name": "Seagate CimarronBP SATA for LA0C FW for model number(s) ST8000NM023B",
      "version": "LA0C",
      "release_id": "P183W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:18:01Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12645613M/4/Serial-ATA_Firmware_P183W_WN64_LA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P183W",
      "size": 23711856,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SATA ISE 512e HDD.  Model number: ST8000NM023B-2TJ133.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for drive returning good status on a download that was interrupted with a link reset.\n- Fix for potential assert during IO test while looping writesame command."
    },
    {
      "id": "b3756f56e76fb6fdf6d53d9bc0bb41fa37aaf9ec858ba959301334044cd538e7",
      "name": "DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR",
      "version": "DL7C",
      "release_id": "VJPKG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-08-19T07:07:49Z",
      "released": "2025-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12600340M/4/Serial-ATA_Firmware_VJPKG_WN64_DL7C_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJPKG",
      "size": 22988728,
      "reboot_required": false,
      "description": "This is a firmware release for DELLSLDM Youngsville-RR  DL7C firmware for Model number(s) SSDSC2KB240GZR, SSDSC2KB480GZR, SSDSC2KB960GZR, SSDSC2KB019TZR, SSDSC2KB038TZR, SSDSC2KB076TZR, SSDSCKKB240GZR, SSDSCKKB480GZR,SSDSC2KG480GZR, SSDSC2KG960GZR, SSDSC2KG019TZR, SSDSC2KG038TZR",
      "revision_history": "Issue: During a warm Reboot the YVRR drive may intermittently disappear when connected to the PERC H965i\nFix: DL7C FW now addresses this issue\nIssue: PLI capacitor charge flag not set leads drive to enter disable logical mode\nFix: DL7C FW now addresses this issue"
    },
    {
      "id": "7de4851004c1bfeabb7fb64a8f7126fea032427318f4ed2b242114da8421a7be",
      "name": "Seagate CimarronBP SATA for FW LC0A for model numbers ST2000NM012B-2TD130, ST4000NM018B-2TF130",
      "version": "LC0A",
      "release_id": "T04YV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:22:43Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12638788M/2/Serial-ATA_Firmware_T04YV_WN64_LC0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T04YV",
      "size": 23567464,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SATA ISE 512n HDD.  Model numbers: ST2000NM012B-2TD130 and ST4000NM018B-2TF130\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for drive returning good status on a download that was interrupted with a link reset.\n- Fix for potential assert during IO test while looping writesame command."
    },
    {
      "id": "79f5dca038dbfec6b6d5e08a95168ae2cb8849a86fefbc19fd111e821c9ecfb5",
      "name": "WDC Paris-C SATA ISE UT09 for model numbers WUH721816ALE6L0, WUH721818ALE6L0.",
      "version": "UT09",
      "release_id": "DK6P7",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-07-17T14:05:56Z",
      "released": "2025-07-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13397419M/1/Serial-ATA_Firmware_DK6P7_WN64_UT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DK6P7",
      "size": 25778688,
      "reboot_required": false,
      "description": "FW update for of  WDC Paris-C SATA ISE.  Model numbers WUH721816ALE6L0, WUH721818ALE6L0.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optiminum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "3d43b16d899574bcaaf624d69349e485c2b6de77f10e32ee06016cfe013710e8",
      "name": "This release contains firmware version HL56 for supplier model number(s) MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "version": "HL56",
      "release_id": "NF72T",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-06-24T17:56:25Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12607145M/2/Serial-ATA_Firmware_NF72T_WN64_HL56_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NF72T",
      "size": 25020384,
      "reboot_required": false,
      "description": "This release contains firmware version HL56 for supplier model number(s)MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "revision_history": "Fixes: \n\n- Disabled Send / Receive FPDMA for QTRIM commands\n- Disabled NCQ Non-Data commands\n- Addressed PLP Timeout / Error Mode by correcting LPage Handles hash algorithm\n- Improved Unmap policy during Sanitize\n- Altered Protective Reclaim (PR) operation to better manange hot-spot reads"
    },
    {
      "id": "ecea33696153990ad446eddf64bc3b31180d12bdb42af975eaf0ec0d89954e53",
      "name": "Samsung HK56 FW for PM897a SATA drive program for model number(s) MZ7L3480HELTAD3, MZ7L3960HELAAD3, MZ7L31T9HENAAD3, MZ7L33T8HENAAD3",
      "version": "HK56",
      "release_id": "KHC8M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:55:37Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12607553M/2/Serial-ATA_Firmware_KHC8M_WN64_HK56_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHC8M",
      "size": 25015744,
      "reboot_required": false,
      "description": "This release contains firmware version HL56 for supplier model number(s)MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "revision_history": "Fixes: \n\n- Disabled Send / Receive FPDMA for QTRIM commands\n- Disabled NCQ Non-Data commands\n- Addressed PLP Timeout / Error Mode by correcting LPage Handles hash algorithm\n- Improved Unmap policy during Sanitize\n- Altered Protective Reclaim (PR) operation to better manange hot-spot reads"
    },
    {
      "id": "44256ed4fef1234a2e8759f3022799cf5ab23aef1ce176d84579f72db233e052",
      "name": "Firmware Update for Toshiba MG10.  Model Number MG10ACA20TEY.",
      "version": "GG03",
      "release_id": "KK671",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:35:49Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12199255M/4/Serial-ATA_Firmware_KK671_WN64_GG03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KK671",
      "size": 24534336,
      "reboot_required": false,
      "description": "Firmware Update for Toshiba MG10.  Model Number MG10ACA20TEY.\nModified Drive Selftest command functionality an changed Background Media Scan default to Enable.",
      "revision_history": "- Reduced the execution time of the Drive selftest command for offline drives.\n- Fixed a bug that would hang if a command was received immediately after starting Random Media Test.\n- Changed the default of Background Media Scan function to Enable."
    },
    {
      "id": "83664d939c9cfb8526c53484a2553d46f8499432e5077ee7074fc0f9d30e0827",
      "name": "Firmware GA09 Update for Longspeak SATA ISE HDD.  Model numbers: ST18000NM008D-3DL133 \u0026 ST20000NM008D-3DJ133",
      "version": "GA09",
      "release_id": "R02JH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-27T09:48:50Z",
      "released": "2025-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12915495M/1/Serial-ATA_Firmware_R02JH_WN64_GA09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R02JH",
      "size": 24250208,
      "reboot_required": false,
      "description": "Firmware Update for Longspeak SATA ISE HDD.  Model numbers: ST18000NM008D-3DL133 \u0026 ST20000NM008D-3DJ133.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Servo code change to address single stage actuator resonance issue in high vibe environment\n- Various performance improvements."
    },
    {
      "id": "c5d54c034608aea2b30ae772d2f1f626db4814ccac68e55449f6043dcf90ab77",
      "name": "HGST RT09 for Vela-AP SATA ISE model number(s) HUS728T8TALE6L0",
      "version": "RT09",
      "release_id": "T0RX4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T09:40:40Z",
      "released": "2024-04-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025871M/1/Serial-ATA_Firmware_T0RX4_WN64_RT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T0RX4",
      "size": 13355792,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SATA HDD, Model number HUS728T8TALE6L0.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "065fa4836a3f37c80b73880763125794567bd147de5257395c832ecef2926d1c",
      "name": "HGST NT11 for model number  HGST HUH721212ALE600.",
      "version": "NT11",
      "release_id": "JCYF6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-08-22T16:02:52Z",
      "released": "2024-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12015624M/1/Serial-ATA_Firmware_JCYF6_WN64_NT11_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JCYF6",
      "size": 13351208,
      "reboot_required": false,
      "description": "This release contains firmware version NT11 for HGST drives. Vendor model number HUH721212ALE600.\nFW update for WDC Leo-A 512e SATA HDD, Model number HUH721212ALE600.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance."
    },
    {
      "id": "298e0c9b3750d7a4b7ac6004a7d6e59f8f42e195e425f9cb59a2f47cdda2e7c0",
      "name": "WD Paris -D  firmware VT18 for  Vendor model numbers WUH722020ALE600 and WUH722020BLE600",
      "version": "VT18",
      "release_id": "P8DY7",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-31T07:48:59Z",
      "released": "2024-03-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11687050M/1/Serial-ATA_Firmware_P8DY7_WN64_VT18_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P8DY7",
      "size": 16621176,
      "reboot_required": false,
      "description": "This release contains firmware version VT18 for WD Paris -D drives. Vendor model number WUH722020ALE600 and WUH722020BLE600.",
      "revision_history": "Fixes:\n- Fix Buffer Timeout error by allowing drive to wait longer for host transfer and not report error while maintaining read performance.\n- Disable PHY power management (partial/slumber).\n- Modifications to Security Library.\n- Remove Latency Monitor code related to Drive Self-test"
    },
    {
      "id": "6c992026ccb1034e5d76c43933dc44c2595da3c48f49b380535843c14de95847",
      "name": "Micron K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "version": "K003",
      "release_id": "RJ0WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T14:41:30Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606437M/2/Serial-ATA_Firmware_RJ0WY_WN64_K003_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJ0WY",
      "size": 12627936,
      "reboot_required": false,
      "description": "This release contains firmware version K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "revision_history": "Fixes:\n\n-Fixes to address performance."
    },
    {
      "id": "7f5691c4430c7327b0a80ce3ef83995daadc50336c7a6a3a67edf9b560b1db34",
      "name": "Micron K403 for 5400 SATA model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB",
      "version": "K403",
      "release_id": "JTW3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T06:58:14Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606566M/2/Serial-ATA_Firmware_JTW3W_WN64_K403_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTW3W",
      "size": 12364032,
      "reboot_required": false,
      "description": "This release contains firmware version K403 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB.",
      "revision_history": "Fixes:\n\n- Fixes to address performance."
    },
    {
      "id": "af718bba045a1770880a3798635bd2970568b875f053f212b6a59895db94ec42",
      "name": "HGST MU03 for model number(s) HUS722T2TALA600 and HUS722T1TALA600.",
      "version": "MU03",
      "release_id": "V3DJM",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:51:43Z",
      "released": "2018-08-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05040482M/6/Serial-ATA_Firmware_V3DJM_WN64_MU03_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3DJM",
      "size": 12145288,
      "reboot_required": false,
      "description": "This release contains firmware version MU03 for HGST drives. Vendor model numbers HUS722T2TALA600 and HUS722T1TALA600.",
      "revision_history": "Fixes\n- Fix for an possible interrupt during Dell factory process during repeated I/O commands.\n\nEnhancements\nn/a"
    },
    {
      "id": "deb059c6403f9a52af3c7261e030a12d42c329643432a1132ddff1931ad627fa",
      "name": "Toshiba GF05 for MG09 SATA 18TB ISE model number(s) MG09ACA18TEY",
      "version": "GF05",
      "release_id": "7R8X7",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-07-23T11:38:03Z",
      "released": "2021-07-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07587612M/1/Serial-ATA_Firmware_7R8X7_WN64_GF05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7R8X7",
      "size": 11152000,
      "reboot_required": false,
      "description": "This release contains firmware version GF05 for Toshiba MG09 SATA 18TB ISE drives - Vendor model number(s) MG09ACA18TEY",
      "revision_history": "Fixes:\n-Initial release"
    },
    {
      "id": "65645d5857702dfa62b35234f1f242791911d0ebba5aa55060456d258e81d3bb",
      "name": "Toshiba FK5D for model number(s) TOSHIBA MG04ACA100NY, TOSHIBA MG04ACA200NY and TOSHIBA MG04ACA400NY.",
      "version": "FK5D",
      "release_id": "V47C4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-07-14T07:08:33Z",
      "released": "2020-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06400316M/1/Serial-ATA_Firmware_V47C4_WN64_FK5D_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V47C4",
      "size": 10624128,
      "reboot_required": false,
      "description": "This release contains firmware version FK5D for Toshiba drives. Vendor model numbers TOSHIBA MG04ACA100NY, TOSHIBA MG04ACA200NY and TOSHIBA MG04ACA400NY.",
      "revision_history": "Fixes:\nSeek algorithm adjusted to reduces spikes in acoustic levels leading to audible noise concerns.\nDEFT algorithm modified to ensure drives with modified seek algorithm will still pass DEFT testing.\n\nEnhancements:\nN/A"
    },
    {
      "id": "b3bdd43b335a4c8a9d5e29d4e9b3c87f0b9b07ce533b4d1e7eeb0fe813120f70",
      "name": "Toshiba GB03 for MG07 ISE model number(s) MG07ACA14TEY and  MG07ACA12TEY",
      "version": "GB03",
      "release_id": "0942Y",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2020-06-23T06:41:48Z",
      "released": "2020-06-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06333095M/1/Serial-ATA_Firmware_0942Y_WN64_GB03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0942Y",
      "size": 10677472,
      "reboot_required": false,
      "description": "This release contains firmware version GB03 for Toshiba MG07 ISE drives - Vendor model number(s) MG07ACA12TEY and MG07ACA14TEY",
      "revision_history": "- Improved the performance for 100MB Random Read/Write.\n- Improved performance for ShortRange Access.\n- Improved performance for ShortRange Access.\n- Fixed the hang by read data xfer in the case of receiving COMRESET.\n- Fixed hang up issue if deep Read Retry occurs and then seek error occurs at the timing when corresponded retry sector is read.\n- Fixed the response of SECURITY ERASE UNIT in the case of following confition.The drive should execute SECURITY ERASE UNIT command only when SECURITY ERASE PREPARE command issues just before SECURITY ERASE UNIT command. If there is any other commands between SECURITY ERASE PREPARE command and SECURITY ERASE PREPARE command,the drive should issue abort. However drive responded normally at even this condition.\n- Improved recovery function when multiple intrenal log broken at power on.\n- Improved the intrenal log loading seqeunce at online FW download.\n- Fixed the internal log loading count at online FW download.\n- Supported for P11 temperature reporting features.\n- Fixed the hang by DownloadMicode CMD in the case of receiving COMRESET.\n- Fixed the issue of internal hang  when Security Erase Unit CMD was recieved from host by unAlign LBA.\n- Fixed the write data currupt when pre-read occurred error in non-Align Access.\n- Added Reverse sequential read Function.\n- Fixed the hang when UnCorrectable error occured at read data transfer.\n- Improved internal que latency at refresh write.\n- improved partial/slumber state time.\n- Changed attribute value ID=5,197 from 512byte unit to 4K byte unit.\n- Improved the performance for 2MB Random Read/Write Mix R70/W30.\n- Fixed the SCT Timeout issue caused by badly management of cache in the case of repetition write to same address.\n- Change interval time for DST to start from 0ms to 500ms.\n- Fixed the NCQ Command response at standby state."
    }
  ]
}