  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "r570",
  "name": "R570",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R570 Urgent Updates",
  "filter": "urgent",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 14,
      "rss": "/r570/urgent/rss.xml",
      "api": "/api/r570/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 69,
      "rss": "/r570/recommended/rss.xml",
      "api": "/api/r570/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 36,
      "rss": "/r570/optional/rss.xml",
      "api": "/api/r570/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r570/bios/rss.xml",
      "api": "/api/r570/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r570/boss/rss.xml",
      "api": "/api/r570/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r570/chipset/rss.xml",
      "api": "/api/r570/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r570/diagnostics/rss.xml",
      "api": "/api/r570/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r570/drivers-for-os-deployment/rss.xml",
      "api": "/api/r570/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 32,
      "rss": "/r570/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r570/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 6,
      "rss": "/r570/fibre-channel/rss.xml",
      "api": "/api/r570/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 2,
      "rss": "/r570/firmware/rss.xml",
      "api": "/api/r570/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r570/idrac/rss.xml",
      "api": "/api/r570/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 17,
      "rss": "/r570/network/rss.xml",
      "api": "/api/r570/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 22,
      "rss": "/r570/sas-drive/rss.xml",
      "api": "/api/r570/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 1,
      "rss": "/r570/sas-non-raid/rss.xml",
      "api": "/api/r570/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 8,
      "rss": "/r570/sas-raid/rss.xml",
      "api": "/api/r570/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/r570/security/rss.xml",
      "api": "/api/r570/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 22,
      "rss": "/r570/serial-ata/rss.xml",
      "api": "/api/r570/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r570/systems-management/rss.xml",
      "api": "/api/r570/systems-management"
    }
  ],
  "count": 14,
  "updates": [
    {
      "id": "195a4057abc496928a98045e4fa6945078fe224fc55c5822aa93847b5a2eedeb",
      "name": "Dell Server PowerEdge BIOS Version 1.10.5",
      "version": "1.10.5",
      "release_id": "17J7V",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-11-09T06:08:57Z",
      "released": "2026-11-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15216591M/1/BIOS_17J7V_WN64_1.10.5.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17J7V",
      "size": 47237984,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced feature sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Fixes:\n- Fixed an issue where the PXE boot device selection could incorrectly map to the wrong NIC interface\nEnhancements:\n- Updated the following:\n- Intel processor and memory reference codes in the Unified Post Launch Release 5 v3545.P.53\n- Intel processor microcode to version 0x3C4 in the Intel Xeon 6700E-series Processors.\n- Intel processor microcode to version 0x164 in the Intel Xeon 6500P-series and 6700P-series Rich I/O Processors\n- Intel processor microcode to version 0x444 in the Intel Xeon 6500P-series and 6700P-series Processors\n- Intel Trusted Domain Extension (TDX) to version 1.5.36.04.1073 for the Intel(R) Xeon(R) 6700E-series Processors\n- Intel Trusted Domain Extension (TDX) to version 2.0.20.00.1074 for the Intel Xeon 6500P-series and 6700P-series Processors\n- Integrated Dell Remote Access Controller (iDRAC) HII settings engine to version 6.0.0.34.\n- Support GNR CPU 2DPC memory configurations up to 6000 MT/s.\n- This product release contains security update DSA-2026-470 and DSA-2026-471. Any security fix information will be accessible on the Dell Security Advisories and Notices website."
    },
    {
      "id": "3c42a5d5d6593d1bb6afbb03bfc0943458d93671a8a9b79d91ec42193d56871e",
      "name": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "GF3PY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-11-03T17:31:07Z",
      "released": "2026-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199882M/1/Express-Flash-PCIe-SSD_Firmware_GF3PY_WN64_1.5.0_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GF3PY",
      "size": 38306408,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release"
    },
    {
      "id": "48c5469a4a346a44cc4729143b3df57c3c9d8a12638878a02ea6a9cd86561b51",
      "name": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "version": "1.0.2",
      "release_id": "1W7Y8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-22T19:07:37Z",
      "released": "2026-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568456M/2/Express-Flash-PCIe-SSD_Firmware_1W7Y8_WN64_1.0.2_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1W7Y8",
      "size": 35321280,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE E3.S Gen5 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected SPDM data offset used when calculating the SPDM manifest.\n2. Enhanced NVMe-MI logic.\n3. Fixed NVMe-MI message response delays; reponses to all NVMe-MI messages within a 100ms timeout period.\n4. Restrict SMBus communication to when the drive is ready to service MCTP/Basic.\n\nEnhancements:\n\n1. Enhanced MCTP processing over SMBus while SMBus is in a reset state.\n2. DUP support for ARM platforms added.\n3. DUP support updated for PERC 12 and 13."
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "102936626baf4012dbcb2aa197a49052eb95905aa41bb5454a517e5a542f21d5",
      "name": "BOSS-N1 DC-MHS Firmware",
      "version": "2.2.13.2038",
      "release_id": "GDT3C",
      "category": "BOSS",
      "category_slug": "boss",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-24T08:38:12Z",
      "released": "2026-05-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14431646M/3/BOSS_Firmware_GDT3C_WN64_2.2.13.2038_A05_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GDT3C",
      "size": 23307616,
      "reboot_required": true,
      "description": "17G BOSS-N1 DC-MHS Package Version 2.2.13.2038",
      "revision_history": "Addressed and improved IO completion status handling"
    },
    {
      "id": "be2552182a26eb88759d7217cc5aefc2cd96994a7322cfad3004048d11f48723",
      "name": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "version": "1.0.2",
      "release_id": "HN0CY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-19T21:48:29Z",
      "released": "2026-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14568517M/1/Express-Flash-PCIe-SSD_Firmware_HN0CY_WN64_1.0.2_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN0CY",
      "size": 29331112,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE U.2 Gen4 Firmware Release",
      "revision_history": "Dell recommends applying this update during your next scheduled update cycle. The update contains feature enhancements or changes that will help keep your system software current and compatible with other system modules (firmware, BIOS, drivers and software)."
    },
    {
      "id": "f7de63ece5daeac08267a48d8bc14fe3582ec54363070acb789f8ff1b32bd6df",
      "name": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "version": "2.0.5",
      "release_id": "34VN7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-18T15:31:12Z",
      "released": "2026-02-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14320085M/1/Express-Flash-PCIe-SSD_Firmware_34VN7_WN64_2.0.5_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=34VN7",
      "size": 27738144,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "revision_history": "N/A"
    },
    {
      "id": "dcbacd995c2a5a32379d174df93ed1431e6552d5a2d2ef0e098973eab0e859ff",
      "name": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release",
      "version": "1.7.0",
      "release_id": "D6RJK",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-10T13:43:02Z",
      "released": "2026-03-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14284736M/1/Express-Flash-PCIe-SSD_Firmware_D6RJK_WN64_1.7.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D6RJK",
      "size": 26508840,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release"
    },
    {
      "id": "2576d421636e87b519086721087196201ac74ebd37755dce4f70eb579e503d8d",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release Maintenance Firmware",
      "version": "1.3.1",
      "release_id": "N78NP",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-03T19:47:31Z",
      "released": "2026-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14259015M/1/Express-Flash-PCIe-SSD_Firmware_N78NP_WN64_1.3.1_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N78NP",
      "size": 27170488,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release - Maintenance Firmware",
      "revision_history": "Fixes:  \n\n1. Improved the firmware to ensure internal PCIe register access is done according to the specification.\n2. Updated the firmware to add SCL detection/protection\n3. Improved firmware to detect the noise on power rail.\n4. Improved firmware to add detection/protection for incomplete Host-Initiated Data Transfer\n5. Improved firmware to add detection/protection for drive Initialization with Poor PCIe Signal Integrity\n6. Improved firmware to add detection and initiate rest/recovery operation to the power management controller upon power on.\n7. Updated the firmware to prevent the deadlock scenario while extended Host Idle Time (no SSD device I/O)\n8. Updated the firmware to Enable PCIe relaxed ordering\n\nEnhancements:  \nN/A"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "d7118a4011a988e2e951915d1cc298925ca524ddf11d30cbbcda0b4011e70320",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.4.0",
      "release_id": "TVCWT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-07-11T04:31:50Z",
      "released": "2025-07-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13369867M/1/Express-Flash-PCIe-SSD_Firmware_TVCWT_WN64_1.4.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TVCWT",
      "size": 29064896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo be added"
    },
    {
      "id": "c2499ab3befc7f8aac45f1eb2b078813e866b63b701d8296d5628475a85b6e14",
      "name": "HGST NS11 for model number(s) HUH721212AL5200 and HUH721212AL4200",
      "version": "NS11",
      "release_id": "04PM5",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:07:34Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12029572M/2/SAS-Drive_Firmware_04PM5_WN64_NS11_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=04PM5",
      "size": 24602048,
      "reboot_required": false,
      "description": "This release contains firmware version NS11 for HGST drives. Vendor model numbers HUH721212AL5200 and HUH721212AL4200.\nFW update for WDC Leo-A 512e SAS HDD, Model number HUH721212AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes. \n'FW update for WDC Leo-A 4Kn SAS HDD, Model number HUH721212AL4200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "065fa4836a3f37c80b73880763125794567bd147de5257395c832ecef2926d1c",
      "name": "HGST NT11 for model number  HGST HUH721212ALE600.",
      "version": "NT11",
      "release_id": "JCYF6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-08-22T16:02:52Z",
      "released": "2024-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12015624M/1/Serial-ATA_Firmware_JCYF6_WN64_NT11_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JCYF6",
      "size": 13351208,
      "reboot_required": false,
      "description": "This release contains firmware version NT11 for HGST drives. Vendor model number HUH721212ALE600.\nFW update for WDC Leo-A 512e SATA HDD, Model number HUH721212ALE600.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance."
    },
    {
      "id": "c3599e7737361231b20cbda8b6430596263c3efdbaf4aa950304a7dda82831a2",
      "name": "Seagate CimarronBP SAS FIPS for LT08 FW for Model numbers: ST8000NM022B",
      "version": "LT08",
      "release_id": "VJ354",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-10-20T17:32:46Z",
      "released": "2021-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07843664M/1/SAS-Drive_Firmware_VJ354_WN64_LT08_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJ354",
      "size": 11717744,
      "reboot_required": false,
      "description": "Seagate CimarronBP SAS FIPS for LT08 FW for Model numbers: ST8000NM022B",
      "revision_history": "Fixes:\nInitial Release"
    }
  ]
}