{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "r540",
  "name": "R540",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R540 Express Flash PCIe SSD Updates",
  "filter": "express-flash-pcie-ssd",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 58,
      "rss": "/r540/urgent/rss.xml",
      "api": "/api/r540/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 198,
      "rss": "/r540/recommended/rss.xml",
      "api": "/api/r540/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 59,
      "rss": "/r540/optional/rss.xml",
      "api": "/api/r540/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r540/bios/rss.xml",
      "api": "/api/r540/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/r540/chipset/rss.xml",
      "api": "/api/r540/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/r540/diagnostics/rss.xml",
      "api": "/api/r540/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r540/drivers-for-os-deployment/rss.xml",
      "api": "/api/r540/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 11,
      "rss": "/r540/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r540/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 17,
      "rss": "/r540/fibre-channel/rss.xml",
      "api": "/api/r540/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 4,
      "rss": "/r540/firmware/rss.xml",
      "api": "/api/r540/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r540/idrac/rss.xml",
      "api": "/api/r540/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 54,
      "rss": "/r540/network/rss.xml",
      "api": "/api/r540/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 112,
      "rss": "/r540/sas-drive/rss.xml",
      "api": "/api/r540/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 13,
      "rss": "/r540/sas-non-raid/rss.xml",
      "api": "/api/r540/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 22,
      "rss": "/r540/sas-raid/rss.xml",
      "api": "/api/r540/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 72,
      "rss": "/r540/serial-ata/rss.xml",
      "api": "/api/r540/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r540/systems-management/rss.xml",
      "api": "/api/r540/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/r540/video/rss.xml",
      "api": "/api/r540/video"
    }
  ],
  "count": 11,
  "updates": [
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "6396852fbfb009e28e3f475ee211608cc3c6c150d5c5f6c446c6b8c8fa29239f",
      "name": "Dell Express Flash NVMe PCIe SSD PM1725b Firmware Release",
      "version": "1.2.2",
      "release_id": "NC07Y",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T09:46:54Z",
      "released": "2025-02-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12666252M/3/Express-Flash-PCIe-SSD_Firmware_NC07Y_WN64_1.2.2_A05_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NC07Y",
      "size": 29801400,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD PM1725b firmware release",
      "revision_history": "New Feature \u0026 Performance enhancements:\nN/A\n\nBug Fixes:\n1. Disable arbitration at the beginning of NSSR so that no invalid status are sent to the host while NSSR is being processed.\n2. Firmware is fixed to set the limit to the suspend check and if no responses back for some time (ex, 5ms), firmware will reset/recover NM code.\n3. Ignore second(SPAM) restart after code completes the first restart."
    },
    {
      "id": "34c7cdbe33ff6937951237e4688c782c36ce0c1a9a134c21f78be30e094dd3e1",
      "name": "Dell Express Flash NVMe P5500/P5600 PCIe SSD Firmware Release",
      "version": "1.2.4",
      "release_id": "CGXH7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-03-07T15:53:46Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09999738M/2/Express-Flash-PCIe-SSD_Firmware_CGXH7_WN64_1.2.4_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CGXH7",
      "size": 17251184,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P5500/5600 PCIe SSD Firmware Release",
      "revision_history": "N/A"
    },
    {
      "id": "6015e77f9438cdd754023cfda5871ba7de0e5e38b506d86bb975cbaaa88f5b36",
      "name": "Dell Express Flash NVMe P4500/P4600 PCIe SSD Firmware Release",
      "version": "QDV1DP17",
      "release_id": "CR0HC",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T21:34:56Z",
      "released": "2020-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06533230M/2/Express-Flash-PCIe-SSD_Firmware_CR0HC_WN64_QDV1DP17_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CR0HC",
      "size": 16645544,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe P4500/P4600 PCIe SSD Firmware Release"
    },
    {
      "id": "069e3208729cb188af47627d87f70bbbb097790d237fb822804eb7ae8f6a1c63",
      "name": "Dell Express Flash NVMe P4800X PCIe SSD Firmware Release",
      "version": "E201DP37",
      "release_id": "RRR52",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-02T21:11:58Z",
      "released": "2021-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07781924M/2/Express-Flash-PCIe-SSD_Firmware_RRR52_WN64_E201DP37_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RRR52",
      "size": 16389248,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe P4800X PCIe SSD Firmware Release",
      "revision_history": "Fixes:\n1.Command timeout on ID controller after PERST\n\nEnhancements:\nN/A"
    },
    {
      "id": "04c1b0629a67a3f4cb7f521f2c0e24758db57c0f75367363cf342366a3149630",
      "name": "Dell PowerEdge Express Flash Ent NVMe AGN SED Firmware Release",
      "version": "1.5.0",
      "release_id": "610WN",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:42:11Z",
      "released": "2023-12-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10871637M/2/Express-Flash-PCIe-SSD_Firmware_610WN_WN64_1.5.0_A06_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=610WN",
      "size": 21649848,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe AGN SED Firmware Release",
      "revision_history": "Fixes:\n\n1. Improved Persistent Event Log behavior.\n2. Improved management interface responsiveness VDM command handling.\n3. Improved temperature reporting.\n\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "17d32c474894380a62ddc1069b6710fa5986fac584390d91f063c236fb97aea9",
      "name": "Dell PowerEdge Express Flash Ent NVMe AGN Firmware Release",
      "version": "2.5.0",
      "release_id": "5CM3G",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:38:47Z",
      "released": "2023-12-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10871579M/3/Express-Flash-PCIe-SSD_Firmware_5CM3G_WN64_2.5.0_A06_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5CM3G",
      "size": 21646664,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. Improved Persistent Event Log behavior.\n2. Improved management interface responsiveness VDM command handling.\n3. Improved temperature reporting.\n\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "e784ff2e12656bb1c69ddc4e608c534f8b9625a9ffcbc8ed60d0d6d60ed8dbd6",
      "name": "Dell Express Flash NVMe PCIe SSD PM1725a firmware release",
      "version": "1.2.0",
      "release_id": "DPG5G",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T17:18:42Z",
      "released": "2020-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06644025M/2/Express-Flash-PCIe-SSD_Firmware_DPG5G_WN64_1.2.0_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DPG5G",
      "size": 18637552,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe PCIe SSD PM1725a firmware release",
      "revision_history": "Bug Fixes:\n1. There are certain SFR ( Special Function Registers ) that are accessed by multiple clients. \n   Since NSSR handler also attempts lock for SFR access, this resulted in a deadlock leading to a timeout. This is recoverable by a power cycle\"\n2. The drive checks SLBA bits based on the HW supports capacity(16TB), so it does not check SLBA[63:35] for non-zero condition.\n3. Firmware Activated bit was not being set in Controller Status on MCTP reply for Controller Health Status Poll command.\n4. New FW that enables reference clock lost interrupt is downloaded on top of FW that doesn't take action on this interrupt.\n5. Issuing NVM Subsystem Health status poll with Clear Status bit set was clearing Controller Health status poll data which caused subsequent Controller Health status poll to return no data.\n6. Response data for Get Message Type Supported MCTP Command was not complete"
    },
    {
      "id": "56088825928a2490073d1688903d8e778f901b211ac34920f33b72d7d3c6b33f",
      "name": "Dell Express Flash NVMe PCIe SSD PM1725b Firmware Release",
      "version": "1.2.1",
      "release_id": "JXWJW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-30T17:14:38Z",
      "released": "2020-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06652670M/2/Express-Flash-PCIe-SSD_Firmware_JXWJW_WN64_1.2.1_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JXWJW",
      "size": 18945960,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD PM1725b firmware release",
      "revision_history": "Bug Fixes:\n1. If the command is moved to LOC retry Q and it is not processed for a certain period of time(32ms), stop processing the new command and process the command of LOC retry Q\n2. The priority if given to the Format command to allow it to complete.  Hence while a format operation is going on the FW will not log unrelated commands timeout. \n3. Correct the search function to find the correct abort command used to abort another command.\n4. The FW change resolves this contention to ensure that this variable is no longer affected by the resource contention issue.  \n5. This change will bypass RO mode and allow the drive to continue normal bringup.  The internal error log file will be re-written at the next error the host is notified on.  \n6. Fixed reset check in reservation bring up path to prevent initialization due to NSSR.  After this change the Reservation is retained."
    }
  ]
}
