  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r4715",
  "name": "R4715",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R4715 Recommended Updates",
  "filter": "recommended",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 11,
      "rss": "/r4715/urgent/rss.xml",
      "api": "/api/r4715/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 60,
      "rss": "/r4715/recommended/rss.xml",
      "api": "/api/r4715/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 20,
      "rss": "/r4715/optional/rss.xml",
      "api": "/api/r4715/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r4715/bios/rss.xml",
      "api": "/api/r4715/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r4715/boss/rss.xml",
      "api": "/api/r4715/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r4715/chipset/rss.xml",
      "api": "/api/r4715/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r4715/diagnostics/rss.xml",
      "api": "/api/r4715/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r4715/drivers-for-os-deployment/rss.xml",
      "api": "/api/r4715/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 17,
      "rss": "/r4715/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r4715/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/r4715/firmware/rss.xml",
      "api": "/api/r4715/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r4715/idrac/rss.xml",
      "api": "/api/r4715/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 10,
      "rss": "/r4715/network/rss.xml",
      "api": "/api/r4715/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 26,
      "rss": "/r4715/sas-drive/rss.xml",
      "api": "/api/r4715/sas-drive"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 7,
      "rss": "/r4715/sas-raid/rss.xml",
      "api": "/api/r4715/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 23,
      "rss": "/r4715/serial-ata/rss.xml",
      "api": "/api/r4715/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 1,
      "rss": "/r4715/systems-management/rss.xml",
      "api": "/api/r4715/systems-management"
    }
  ],
  "count": 60,
  "updates": [
    {
      "id": "0977dfbae8a40a6e966730b9138c338cd5e985d9f63aa6ac5dd14dcf8700cee4",
      "name": "iDRAC 1.30.65.51",
      "version": "1.30.65.51",
      "release_id": "C21YH",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-06T13:39:20Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213660M/1/iDRAC-with-Lifecycle-Controller_Firmware_C21YH_WN64_1.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C21YH",
      "size": 357946640,
      "reboot_required": false,
      "description": "iDRAC 1.30.65.51",
      "revision_history": "Fixes\n- Fixed the issue where Serbia was missing from the country code list in the iDRAC SSL/TLS CSR interface.\n- Fixed the issue where iDRAC 1.30.40.51 returns HTTP 400 when accessing Web GUI via FQDN despite HostHeaderCheck being disabled.\n- Fixed the issue where iDRAC time never reverts to RTC if NTP is unavailable.\n- Fixed the issue where SWC9048 error message appears when trying to launch iDRAC IP from UI after updating iDRAC firmware with FIPS enabled.\n- Fixed the issue where SystemCurrentCapLimit and SystemCurrentCapSetting options were missing in racadm get/set system.ServerPwr output while GridCurrentCapLimit settings were exposed.\n- Fixed the issue where STOR090 error occurred when failing to import OMEnt template and SCP when Dedicated HotSpare is present on PERC H965i.\n- Fixed the issue where iDRAC10 SCP export command fails via RACADM for iDRAC firmware version 1.30.40.51.\n- Fixed the issue where GPU Temperature Probe Readings were missing in SNMP and ProbeStatus appeared in unknown state after upgrading to iDRAC 1.30.40.51.\n- Fixed the issue where fans were spinning at 100% when system idle on PowerEdge XE9785 with AMD Pensando Pollara 400 AI Network Interface Card (NIC).\n\n\nEnhancements:\n- Added filter options in iDRAC for SAS address.\n- Fixed the issue where banner for functional pages was still observed when system is in lockdown mode.\n- Added Redfish support to delete AD/LDAP certificates.\n- Populated Redfish Volume Identifiers with durable identifier for PERC RAID virtual disks.\n- Added support to Redfish action EventService.SubmitTestEvent to send test events to Server-Sent Events.\n- Added Redfish support to retrieve configuration preview results for a Job ID.\n- Added Redfish support to reset Storage Controller to defaults.\n- Updated battery page and rollup status design.\n- Added the ability to mount virtual images from S3 for iDRAC.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification.\n- Improved Redfish error messaging for BootSourceOverride failure in iDRAC10.\n- Added OpenID Connect with Azure Entra ID support.\n- Added low privilege iDRAC Operator role.\n- Enabled email alerts for thermal-related GPU/TMP events.\n- Added SMTP modern authentication (OAuth2) support.\n- Enabled email alerts for critical PCI errors (PCI3039/PCI3040) in iDRAC10.\n- Added iDRAC10 BIOS Console Log Retention for serviceability.\n- Added block-level erase and cryptographic validation for iDRAC partitions in SystemErase.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero-Touch Bootstrap.\n- Added support for SID/OPAL/PSID drive status property.\n- Enabled Full APO (Automatic Power On) support for FullPowerReset.\n- Added fan board page health rollup into overall system health.\n- Fixed iDRAC delay in MEM message logging that caused incorrect event ordering.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message.\n- Aligned MultipartUpload ApplyTime behavior with SimpleUpdate (OnStartUpdateRequest).\n- Added BIN Catalog update support.\n- Added native iDRAC10 support for Open Telemetry (OTEL) metric streaming.\n- Added Component-Level Firmware Update and Discoverability via Redfish.\n- Added support for custom HTTP ports for InstallFromRepository via iDRAC UI, Redfish, and RACADM.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior.\n- Added iDRAC support for controlling the SMA_OUT source select.\n- Added support in iDRAC to control the timing module Write_en pin and timing module reset pin with host control via Redfish.\n- Enabled PSU firmware update when single PSU is installed.\n- Added iDRAC CMP V2 support on PowerEdge XR8720T.\n- Added iDRAC uptime to sysinfo.\n- Enhanced iDRAC10 UI usability with VLAN placement, search/filter"
    },
    {
      "id": "0a074b7baf9230d0123992106f1ffc54676267f5d904e02caacc508913a8c1d9",
      "name": "PERC12 H365i Adapter RAID Controller firmware version 8.19.0.0.15-65",
      "version": "8.19.0.0.15-65",
      "release_id": "32YTC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:44:53Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194860M/2/SAS-RAID_Firmware_32YTC_WN64_8.19.0.0.15-65_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=32YTC",
      "size": 30442896,
      "reboot_required": false,
      "description": "This release updates the firmware residing on H365i Adapter RAID Controller to package8.19.0.0.15-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\nAdded support to import foreign virtual drives with Read-Ahead cache settings by automatically converting them to No Read Ahead during import in eHBA mode.\n \nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis"
    },
    {
      "id": "eb8c58613500f7fca3d7c2821fc2d3abfa37934cbe74e9ff7c06ef831aa28508",
      "name": "PERC H965i Front Controller for Dell PowerEdge 17G Generation of Servers firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "3K8FC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:43:54Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195090M/2/SAS-RAID_Firmware_3K8FC_WN64_8.19.0.0.18-65_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3K8FC",
      "size": 30451176,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H965i Front Controller for Dell PowerEdge 17G Generation of Servers to package 8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "ef67956cb25fd3a7709bd5ab3db4f05c7dcc8cb05a69757e03b5656bc773aa7c",
      "name": "PERC H965i Adapter RAID Controller firmware version 8.19.0.0.18-65",
      "version": "8.19.0.0.18-65",
      "release_id": "520P8",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T11:39:55Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194782M/2/SAS-RAID_Firmware_520P8_WN64_8.19.0.0.18-65_A13.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=520P8",
      "size": 30451152,
      "reboot_required": false,
      "description": "This release updates the firmware residing on PERC H965i Adapter RAID Controller to package 8.19.0.0.18-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active.\nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\n\nEnhancements:\n=============\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "f451277edca8929f7744d1fcf43bd2ee7276900f4dfbce68d512f2c6fbca83a1",
      "name": "PERC12 H365I DC-MHS RAID Controller firmware version 8.19.0.0.15-65",
      "version": "8.19.0.0.15-65",
      "release_id": "JDRJP",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T06:37:39Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15194852M/2/SAS-RAID_Firmware_JDRJP_WN64_8.19.0.0.15-65_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDRJP",
      "size": 30442912,
      "reboot_required": false,
      "description": "PERC12 H365I DC-MHS RAID Controller firmware version 8.19.0.0.15-65",
      "revision_history": "Fixes:\n======\nFixed an issue where controller fault could occur during a Function Level Reset (FLR) when concurrent I/O and task management operations are active. \nFixed an issue that could cause a firmware fault when an online controller operation occurred while a sanitize operation was in progress.\nFixed an issue where Auto Device Assignment was incorrectly enabled under the Ignore Auto Assign policy.\nAdded support to import foreign virtual drives with Read-Ahead cache settings by automatically converting them to No Read Ahead during import in eHBA mode.\n \nEnhancements: \n=============\nOptimizations and Improvements from Static Code Analysis"
    },
    {
      "id": "a5d07ba978a43fb98b620e9772c2b9781c7c88a95244ad0c3d5d40b728298959",
      "name": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "NKCW4",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-03T15:09:31Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199461M/1/SAS-RAID_Driver_NKCW4_WN64_8.19.6.0_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKCW4",
      "size": 17814352,
      "reboot_required": true,
      "description": "Windows Server 2025 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\n\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\n\nDriver Code optimization in IO completion path."
    },
    {
      "id": "c4353be1f75b45627e460e935d416b30929f3c9ceffd49a4970f42706b141bab",
      "name": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "version": "8.19.6.0",
      "release_id": "YTR3P",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-02T18:49:59Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15195250M/1/SAS-RAID_Driver_YTR3P_WN64_8.19.6.0_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YTR3P",
      "size": 17813192,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes\n=====\nFixed system crash in adapter control path during stop adapter.\nFixed performance drop observed in SAS4 SSD Drives setup.\nFixed Device QD failure issue.\n\nEnhancement\n===========\nDriver Code optimization in IO completion path."
    },
    {
      "id": "69a58ee638d7dd383229f7edeb9f9319c1937db810aeee75697ddd20288506cc",
      "name": "NVIDIA Mellanox Windows 64-bit Server OS Drivers for Mellanox ConnectX-4 LX, ConnectX-5, ConnectX-6 and ConnectX-7, ConnectX-8 Adapters",
      "version": "25.010.100",
      "release_id": "054K7",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-02T07:42:07Z",
      "released": "2026-08-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14932497M/2/Network_Driver_054K7_WN64_25.010.100_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=054K7",
      "size": 322683056,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, and ConnectX-7, ConnectX-8 NIC drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "1dfc69717a0c357d41f49286fe59e78a2c4fcacd649a8c48425eb8d24d3adb47",
      "name": "Windows 2022 drivers for H975i, H965i, H365i and HBA465 controllers",
      "version": "8.14.6.0",
      "release_id": "V3P66",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-09-09T13:37:59Z",
      "released": "2026-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14017149M/4/SAS-RAID_Driver_V3P66_WN64_8.14.6.0_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3P66",
      "size": 17570512,
      "reboot_required": true,
      "description": "Windows 2022 drivers for H975, H965, H365 and HBA465 controllers",
      "revision_history": "Fixes:\n=====\nResolved system crash observed after factory reset of the controller.\nFixed issue where crash dump was not generated when Virtualization-Based Security (VBS) was enabled.\n\nEnhancement:\n===========\nNA"
    },
    {
      "id": "1fb28c0380763cd1be341debcd11b6236a4df5618102f08eeb185557c42b189f",
      "name": "Toshiba MG08AD SATA ISE drive program for GE03 FW for model number(s): MG08ADA800EY",
      "version": "GE03",
      "release_id": "X5MGP",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-21T16:04:50Z",
      "released": "2026-01-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13881309M/2/Serial-ATA_Firmware_X5MGP_WN64_GE03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X5MGP",
      "size": 23249648,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG08AD SATA ISE.  Model number MG08ADA800EY.",
      "revision_history": "- Fixed an issue which could cause a drive hang if power is interrupted twice in a row\n- Fixed a problem that caused Drive Self-Test in Captive mode to terminate with an error immediately after Online Download.\n- Fixed a potential issue if power was lost while saving parameters to Flash ROM during the FW download process.\n- Changed the write data transfer conditions so that Hold Primitive does not occur."
    },
    {
      "id": "cca5695e4a8e61074fdc1de3a322725393df6e48f8498fa5f2dd6e2c301186f7",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "71KRG",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-12-16T18:48:47Z",
      "released": "2025-09-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13990425M/1/Express-Flash-PCIe-SSD_Firmware_71KRG_WN64_1.2.0_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=71KRG",
      "size": 29639544,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Improvements to drive internal logging.\n2. Improvements to SMART logging and notification.\n3. Resolved sideband firmware download issue.\n\nEnhancements:\n\n1. Additional support added for firmware update for Dell 17th generation servers.\n2. Additional support added for firmware update for Dell PERC 12 and 13 controllers."
    },
    {
      "id": "02286d72f669c005452804c6682322adb99d5abb1748762b5742f8ed0eacaeb9",
      "name": "Samsung HK58 FW for PM897a SATA drive program for model number(s) MZ7L3480HELTAD3, MZ7L3960HELAAD3, MZ7L31T9HENAAD3, MZ7L33T8HENAAD3",
      "version": "HK58",
      "release_id": "V5XNY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T15:24:01Z",
      "released": "2025-09-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13895112M/1/Serial-ATA_Firmware_V5XNY_WN64_HK58_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V5XNY",
      "size": 23609288,
      "reboot_required": true,
      "description": "This update includes optimizations to reset handling, log collections, and SMART attribute handling.  Version HK58 firmware for Samsung PM897a SATA SSDs, models MZ7L3480HELT-00AD3,  MZ7L3960HELA-00AD3,  MZ7L31T9HENA-00AD3,  MZ7L33T8HENA-00AD3.",
      "revision_history": "Fixes:\n\n- Altered Reset handling to respond to all COMRST commands within 1 sec.\n- Altered DRAM allocation for live dumps, to eliminate FW assert due to max. allocation count\n- Eliminated debug log check during Open, to eliminate fake UECC written during DTT shutdown\n\nEnhancement:\n\n- Changed SMART Attributes 173, 175, and 177 to Advisory."
    },
    {
      "id": "e846d6c1ff5659ce2b77ca6d67f8125ae920ef3bc41f09ffce056334e4fc547b",
      "name": "This release contains firmware version HL58 for supplier model number(s) MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "version": "HL58",
      "release_id": "D5D3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T15:19:35Z",
      "released": "2025-09-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13895080M/1/Serial-ATA_Firmware_D5D3W_WN64_HL58_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D5D3W",
      "size": 23613616,
      "reboot_required": true,
      "description": "This update includes optimizations to reset handling, log collections, and SMART attribute handling.  Version HL58 firmware for Samsung PM893a SATA SSDs, models  MZ7L3960HELT-00AD3,  MZ7L31T9HELA-00AD3,  MZ7L33T8HELA-00AD3, MZ7L37T6HELA-00AD3.",
      "revision_history": "Fixes: \n\n- Altered Reset handling to respond to all COMRST commands within 1 sec.\n- Altered DRAM allocation for live dumps, to eliminate FW assert due to max. allocation count\n- Eliminated debug log check during Open, to eliminate fake UECC written during DTT shutdown\n\nEnhancement:\n\n- Changed SMART Attributes 173, 175, and 177 to Advisory."
    },
    {
      "id": "ee13dd1701927e0c509aec12d44a532a83613d5861fe3095347b3fe955f638d1",
      "name": "Firmware update for WDC Paris-CP SATA ISE Model Numbers: WUH722012CLE600, WUH722016CLE600",
      "version": "AT05",
      "release_id": "P3H57",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T15:13:18Z",
      "released": "2025-11-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13895027M/1/Serial-ATA_Firmware_P3H57_WN64_AT05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P3H57",
      "size": 25138248,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP SATA ISE Model Numbers: WUH722012CLE600, WUH722016CLE600.\nCode updated to fix potential issue during Dell Factory Test.",
      "revision_history": "Firmware update to address potential issue during Dell Enhanced Factory Test."
    },
    {
      "id": "c73beccb3d67ad1b365735cea9aefae76310134df79570616d77bd8f290f431d",
      "name": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205",
      "version": "AM05",
      "release_id": "HTW37",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T10:16:13Z",
      "released": "2025-11-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13893761M/1/SAS-Drive_Firmware_HTW37_WN64_AM05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HTW37",
      "size": 25081440,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205.\nCode updated to fix potential issue during Dell Factory Test.",
      "revision_history": "Firmware update to address potential issue during Dell Enhanced Factory Test."
    },
    {
      "id": "005e59ae0ca89864a59fc7208c7f941cca8d88f2b4b149b4876d3547c0b6ea7a",
      "name": "Firmware update for WDC Paris-CP SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200",
      "version": "AS05",
      "release_id": "VK0PK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T06:24:38Z",
      "released": "2025-11-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13892401M/1/SAS-Drive_Firmware_VK0PK_WN64_AS05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VK0PK",
      "size": 25069096,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200.\nCode updated to fix potential issue during Dell Factory Test.",
      "revision_history": "Firmware update to address potential issue during Dell Enhanced Factory Test."
    },
    {
      "id": "76e7ada98d033dda19e13f8cee07dec5f65a42f60d2ea730a362f843cd46487e",
      "name": "Toshiba GF08 for MG09 SATA ISE model number(s) MG09ACA18TEY, MG09ACA16TEY, and MG09ACA12TEY",
      "version": "GF08",
      "release_id": "KMTGF",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-10-21T08:59:24Z",
      "released": "2025-10-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13765916M/1/Serial-ATA_Firmware_KMTGF_WN64_GF08_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KMTGF",
      "size": 23525440,
      "reboot_required": false,
      "description": "FW update for of Toshiba MG09 SATA ISE.  Model numbers MG09ACA18TEY, MG09ACA16TEY, and MG09ACA12TEY.\nFix for a Background Medium Scan issue and potential timeout.",
      "revision_history": "- Fixed a problem during Background Medium Scan or Drive Self-test in which a long read with command interrupt disabled was performed under certain conditions and other commands could not be executed.\n- Fixed the issue that could cause a SCT timeout response to fail after Flush Cache Command.\n- Fixed the issue that write commands are abnormally executed two times internally and cause BCRC error or SATA I/F protocol error."
    },
    {
      "id": "3735b6b54fcf04cd59cca7137654bb59c8fcdefecff53476ea296922b2fd6175",
      "name": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\nFW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.",
      "version": "PV10",
      "release_id": "8R6W6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-25T09:20:50Z",
      "released": "2025-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13676887M/1/Serial-ATA_Firmware_8R6W6_WN64_PV10_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8R6W6",
      "size": 23949896,
      "reboot_required": false,
      "description": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\n'FW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.\nIncludes FW update to add recognition of 2TB SATA capacity part number",
      "revision_history": "FW update to add Dell Part Number for newly added 2TB capacity"
    },
    {
      "id": "f0c7c33f6a4f201f2f057bdb96f86911a0ec0cd66093d0e463fd502f62819caf",
      "name": "Firmware Update for EvansBP SATA ISE HDD.  Model numbers: ST12000NM002J-2TY133, ST14000NM002J-2TX133, ST16000NM002J-2TW133, ST18000NM002J-2TV133\n\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing",
      "version": "PALB",
      "release_id": "4MPD6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T15:57:45Z",
      "released": "2025-01-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12476257M/4/Serial-ATA_Firmware_4MPD6_WN64_PALB_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4MPD6",
      "size": 23564640,
      "reboot_required": false,
      "description": "This package contains firmware version PALB for Seagate drives (vendor Model numbers: ST12000NM002J-2TY133, ST14000NM002J-2TX133, ST16000NM002J-2TW133, ST18000NM002J-2TV133)",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command\n- Fix for potential assert during Write Uncorrectable testing\n- Shorten time delay before running Direct Offline Scan"
    },
    {
      "id": "da54c7c652c628a110f777d83c5f4bdcb43dcf128a9c396de02d53db2bce1188",
      "name": "Initial release of MG10SD 512n and 512e SAS.Model numbers MG10SDA200NY,MG10SDA400NYand MG10SDA800EY.",
      "version": "EP02",
      "release_id": "99TKP",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T15:01:17Z",
      "released": "2024-11-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12164931M/2/SAS-Drive_Firmware_99TKP_WN64_EP02_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=99TKP",
      "size": 23548480,
      "reboot_required": false,
      "description": "This release contains FW revision EP02 for model numbers MG10SDA200NY,MG10SDA400NYand MG10SDA800EY.",
      "revision_history": "-Initial release."
    },
    {
      "id": "45228c5635928cde92a1f46643d5a35b22ba672a72066d533bdcab54789eec75",
      "name": "Seagate CimarronBP SATA for LA0C FW for model number(s) ST8000NM023B",
      "version": "LA0C",
      "release_id": "P183W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:18:01Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12645613M/4/Serial-ATA_Firmware_P183W_WN64_LA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P183W",
      "size": 23711856,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SATA ISE 512e HDD.  Model number: ST8000NM023B-2TJ133.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for drive returning good status on a download that was interrupted with a link reset.\n- Fix for potential assert during IO test while looping writesame command."
    },
    {
      "id": "41d8ddf307b4ef32924e88af9618acf8165484bb258955e0c6381fffd74cec21",
      "name": "Seagate SBTA for Skybolt ServoBP program for model number(s) CL2400MM0149",
      "version": "SBTA",
      "release_id": "HH6J1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:02:18Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12677112M/2/SAS-Drive_Firmware_HH6J1_WN64_SBTA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HH6J1",
      "size": 23874432,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512n ISE. Model Number CL2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "4c6ed6166ab2e1a3e699af648e5457cd81edd18f87e2beea7561f7262fa1fa6d",
      "name": "Seagate SBSA for Skybolt ServoBP program for model number(s) BL2400MM0159",
      "version": "SBSA",
      "release_id": "00P56",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:22:58Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676520M/2/SAS-Drive_Firmware_00P56_WN64_SBSA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=00P56",
      "size": 23874416,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512e ISE.  Model Number BL2400MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "488b6d18b0e0ce3ac333ac5692fdf90c286b1f6fbbc6ac6a30f8212c5813f8ad",
      "name": "Firmware Update for EvansBP SAS ISE HDD. Model numbers: ST12000NM006J, ST14000NM006J, ST16000NM006J, ST18000NM006J",
      "version": "PSLG",
      "release_id": "XF65R",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:36:19Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12783645M/2/SAS-Drive_Firmware_XF65R_WN64_PSLG_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XF65R",
      "size": 23710648,
      "reboot_required": false,
      "description": "This release contains firmware version PSLG for Seagate drives. Vendor model numbers ST12000NM006J, ST14000NM006J, ST16000NM006J, ST18000NM006J.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Shorten time delay before running Direct Offline Scan"
    },
    {
      "id": "0c35e7ef25c69e2ab6c9f4c82eb0b9bba7107da2d604217f9dcd9d9848a86e2a",
      "name": "Seagate CimarronBP SAS ISE for FW LS0E for model numbers: ST8000NM024B",
      "version": "LS0E",
      "release_id": "FJ97K",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:32:22Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12816090M/2/SAS-Drive_Firmware_FJ97K_WN64_LS0E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FJ97K",
      "size": 24019096,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS ISE 512e HDD.  Model number: ST8000NM024B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "7de4851004c1bfeabb7fb64a8f7126fea032427318f4ed2b242114da8421a7be",
      "name": "Seagate CimarronBP SATA for FW LC0A for model numbers ST2000NM012B-2TD130, ST4000NM018B-2TF130",
      "version": "LC0A",
      "release_id": "T04YV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:22:43Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12638788M/2/Serial-ATA_Firmware_T04YV_WN64_LC0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T04YV",
      "size": 23567464,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SATA ISE 512n HDD.  Model numbers: ST2000NM012B-2TD130 and ST4000NM018B-2TF130\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for drive returning good status on a download that was interrupted with a link reset.\n- Fix for potential assert during IO test while looping writesame command."
    },
    {
      "id": "79f5dca038dbfec6b6d5e08a95168ae2cb8849a86fefbc19fd111e821c9ecfb5",
      "name": "WDC Paris-C SATA ISE UT09 for model numbers WUH721816ALE6L0, WUH721818ALE6L0.",
      "version": "UT09",
      "release_id": "DK6P7",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-07-17T14:05:56Z",
      "released": "2025-07-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13397419M/1/Serial-ATA_Firmware_DK6P7_WN64_UT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DK6P7",
      "size": 25778688,
      "reboot_required": false,
      "description": "FW update for of  WDC Paris-C SATA ISE.  Model numbers WUH721816ALE6L0, WUH721818ALE6L0.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optiminum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "44256ed4fef1234a2e8759f3022799cf5ab23aef1ce176d84579f72db233e052",
      "name": "Firmware Update for Toshiba MG10.  Model Number MG10ACA20TEY.",
      "version": "GG03",
      "release_id": "KK671",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:35:49Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12199255M/4/Serial-ATA_Firmware_KK671_WN64_GG03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KK671",
      "size": 24534336,
      "reboot_required": false,
      "description": "Firmware Update for Toshiba MG10.  Model Number MG10ACA20TEY.\nModified Drive Selftest command functionality an changed Background Media Scan default to Enable.",
      "revision_history": "- Reduced the execution time of the Drive selftest command for offline drives.\n- Fixed a bug that would hang if a command was received immediately after starting Random Media Test.\n- Changed the default of Background Media Scan function to Enable."
    },
    {
      "id": "56221de0237fbeeb680e5eac2cb8d3e0f72799000d1986cf8fb68d7d02d297cd",
      "name": "Seagate SSEJ for model number(s) ST2400MM0149",
      "version": "SSEJ",
      "release_id": "KHJ9C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:13:51Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676334M/3/SAS-Drive_Firmware_KHJ9C_WN64_SSEJ_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHJ9C",
      "size": 24679816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512n ISE. Model Number ST2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "- Add support for Hynix V8 NAND part."
    },
    {
      "id": "59399b6ce0f13bd5649446151ad7d9a072c6d8c70f4a2f7abe335ef870bbace4",
      "name": "Dell Express Flash NVMe PCIe SSD 6500 U.2 ISE Firmware Release",
      "version": "1.1.0",
      "release_id": "NRKF4",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T07:30:48Z",
      "released": "2024-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12096577M/2/Express-Flash-PCIe-SSD_Firmware_NRKF4_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NRKF4",
      "size": 29254888,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 6500 U.2 ISE Firmware Release",
      "revision_history": "Fixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "94586f99bddb6d07e51ebf78479fa5de5fb353777dec7e7bb0b73c704b3c21bf",
      "name": "Dell Datacenter NVME RI AGN ISE",
      "version": "1.1.1",
      "release_id": "XMFKX",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:50:32Z",
      "released": "2024-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12037085M/2/Express-Flash-PCIe-SSD_Firmware_XMFKX_WN64_1.1.1_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XMFKX",
      "size": 30415680,
      "reboot_required": false,
      "description": "Dell Datacenter NVME RI AGN ISE",
      "revision_history": "Fixes:\n\n1. Updated DUP framework for 17G server platforms."
    },
    {
      "id": "20bf714b8e559377da3eab75736f36b9641946091085d1475a770d95de77f284",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "version": "3.0.4",
      "release_id": "8T6F8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-16T12:34:15Z",
      "released": "2025-05-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13259395M/1/Express-Flash-PCIe-SSD_Firmware_8T6F8_WN64_3.0.4_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8T6F8",
      "size": 29998824,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "revision_history": "Fixes:  \n\n1. When the reference clock is turned off after a PERET# assertion interrupt or a reference clock off interrupt, the CPU never accesses the MAC register until the PIPE clock is restored after PERST# de-assertion.\n2. PHY reset during Hot Reset or Link Disabled is not mandatory, so this process can be skipped. This measure shortens the transition time from Detect to Polling.Active from 70 ms to about 10 ms.\n3. Add flag to prevent DRAM Self Refresh from being triggered.\n4. Once a specific Block has been marked as a bad block that is not to be used, an erase error on the bad block will not cause the Block Erase operation to fail.\n5. The drive FW is modified to suspend the DMAC operation by the drive internal CPU for snapshot saving during the Low power transition.\n6. Fix the Max PE Cycle values mismatch issue for MU 12TB and RI 30TB\n\nEnhancements:  \nN/A"
    },
    {
      "id": "7d93b47a9d1b92fb19afd5ae11efa61fdc5a6d79b95659c25c9029fdba7db904",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.3",
      "release_id": "K1JTM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-13T21:13:35Z",
      "released": "2025-05-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13253883M/1/Express-Flash-PCIe-SSD_Firmware_K1JTM_WN64_2.0.3_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K1JTM",
      "size": 29789880,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n\n1. When the reference clock is turned off after a PERET# assertion interrupt or a reference clock off interrupt, the CPU never accesses the MAC register until the PIPE clock is restored after PERST# de-assertion.\n2. PHY reset during Hot Reset or Link Disabled is not mandatory, so this process can be skipped. This measure shortens the transition time from Detect to Polling.Active from 70 ms to about 10 ms.\n3. Add flag to prevent DRAM Self Refresh from being triggered.\n4. Once a specific Block has been marked as a bad block that is not to be used, an erase error on the bad block will not cause the Block Erase operation to fail.\n5. The drive FW is modified to suspend the DMAC operation by the drive internal CPU for snapshot saving during the Low power transition.\n6. Fix the Max PE Cycle values mismatch issue for MU 12TB and RI 30TB\n\nEnhancements:  \nN/A"
    },
    {
      "id": "9af16c01a996600f0ca7ca41fae9ce3cd6a2c5aa191bd93b4454b7d2e7ed7fba",
      "name": "Western Digital Paris-D PR2 SAS VS19 firmware for model number WUH722020BL5200",
      "version": "VS19",
      "release_id": "XRFX3",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-19T13:58:09Z",
      "released": "2025-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13133280M/1/SAS-Drive_Firmware_XRFX3_WN64_VS19_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XRFX3",
      "size": 27819864,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-D PR2 SAS ISE.  Model number WUH722020AL5200.\nFW improvement to remove undesired self-initiated reset as a result of statistical counter overflow.",
      "revision_history": "Remove undesired self-initiated reset which could occur when large number of messages were sent since last power cycle"
    },
    {
      "id": "3a1ec62e9d91018b613e8a1f2d3d331fcf810f9a8958328c9acf8fbdc2ee855b",
      "name": "WD Paris -D  firmware VT19 for  Vendor model numbers WUH722020ALE600 and WUH722020BLE600",
      "version": "VT19",
      "release_id": "P09WG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-19T10:34:08Z",
      "released": "2025-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13132435M/1/Serial-ATA_Firmware_P09WG_WN64_VT19_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P09WG",
      "size": 27888568,
      "reboot_required": false,
      "description": "This release contains firmware version VT19 for WD Paris -D drives. Vendor model number WUH722020ALE600 and WUH722020BLE600. FW improvement to remove undesired self-initiated reset as a result of statistical counter overflow.",
      "revision_history": "Remove undesired self-initiated reset which could occur when large number of messages were sent since last power cycle"
    },
    {
      "id": "71af61175e4f3eac89532ba8060f2ca55c2c02ee56a6a3786739e80d99963fb6",
      "name": "Hynix SE5110 ISE RI DZ03 Firmware for  model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N",
      "version": "DZ03",
      "release_id": "7XTPF",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-12T11:41:46Z",
      "released": "2025-02-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13101768M/1/Serial-ATA_Firmware_7XTPF_WN64_DZ03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7XTPF",
      "size": 28384904,
      "reboot_required": false,
      "description": "This release contains initial firmware DZ03 for Hynix SE5110 ISE. Model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N.",
      "revision_history": "Fixes: \n\n- Fix1: DZ03 FW now addresses this issue.  Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory. \n- Fix2: DZ03 FW now addresses this issue. Delete 1bit error case in NIOE uCode SRAM area under NIOE Interrupt occurrence condition.  \n- Fix3: DZ03 FW now addresses this issue.  When all Program CHDMA responses are received, Program Done is processed."
    },
    {
      "id": "94cddbcf632ba8d62bf8fd89359de9b60c19a24649fa5a370ba55cb90e9ddaad",
      "name": "Seagate CimarronBP SAS for FW LW0B for model numbers ST2000NM013B, ST4000NM019B",
      "version": "LW0B",
      "release_id": "3P5N0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-16T09:10:59Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12648511M/2/SAS-Drive_Firmware_3P5N0_WN64_LW0B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3P5N0",
      "size": 24698960,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS ISE 512n HDD.  Model numbers: ST2000NM013B and ST4000NM019B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "9d3a909718077b49b7c8c9902c53facf85f1cfdfc24edabfce073cd264cc800c",
      "name": "Hitachi PU09 for Vela-A ISE model number(s) HUS726T4TALS200",
      "version": "PU09",
      "release_id": "J5K8G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T11:03:41Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024400M/2/SAS-Drive_Firmware_J5K8G_WN64_PU09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J5K8G",
      "size": 24727008,
      "reboot_required": false,
      "description": "FW update for WDC Vela-A 512n SAS HDD, Model number HUS726T4TALS200.\n\n- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "851192910676f62564014c1ffe71bea150f0ccd442fae8c4d0e4d63fda7efb42",
      "name": "Toshiba EF09 for model number(s) AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY",
      "version": "EF09",
      "release_id": "J11N2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T10:54:37Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12128055M/2/SAS-Drive_Firmware_J11N2_WN64_EF09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J11N2",
      "size": 23842608,
      "reboot_required": false,
      "description": "This release contains firmware version EF09 for Toshiba drives. Vendor model numbers AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY.\nRevert high fly write detection methodology back to process used in previous EF06 Firmware",
      "revision_history": "Revert high fly write detection methodology back to process used in previous EF06 Firmware."
    },
    {
      "id": "16d815594594e4b89b41fc3df9d5d41134c87af99c69f80304491790c7da00d7",
      "name": "Firmware Update for WDC London-DP SAS ISE Model Numbers WUH722420AL5200 \u0026 WUH722424AL5200.\nFirmware fix for potential self-initiated reset if commands are sent from an invalid lun.",
      "version": "YS04",
      "release_id": "444T3",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-10T09:46:39Z",
      "released": "2025-04-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12979078M/1/SAS-Drive_Firmware_444T3_WN64_YS04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=444T3",
      "size": 28009224,
      "reboot_required": false,
      "description": "Firmware Update for WDC London-DP SAS ISE Model Numbers WUH722420AL5200 \u0026 WUH722424AL5200.\nFirmware fix for potential self-initiated reset if commands are sent from an invalid lun.",
      "revision_history": "- Firmware fix for potential self-initiated reset if commands are sent from an invalid lun, due to decrementing wrong register.  New firmware fix ensures correct register is decremented.\n- Set WriteSame command LED blink rate to ten times a second.\n- Improve debug data collection during self-initiated resets."
    },
    {
      "id": "a7930f478f59c95527ae41652c0eba437e48b165aaad97478b45e4ad35478441",
      "name": "Firmware Update for WDC London-DP SATA ISE Model Numbers WUH722420ALE600 \u0026 WUH722424ALE600.\nFirmware fix for potential self-initiated reset if commands are sent from an invalid lun.",
      "version": "YT04",
      "release_id": "6TFV4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-09T07:13:36Z",
      "released": "2025-04-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12972937M/1/Serial-ATA_Firmware_6TFV4_WN64_YT04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6TFV4",
      "size": 28089736,
      "reboot_required": false,
      "description": "This release contains firmware version YT04 for Western Digital London-D SATA drives - Vendor model number(s) WUH722420ALE600 \u0026 WUH722424ALE600.",
      "revision_history": "- Firmware fix for potential self-initiated reset if commands are sent from an invalid lun, due to decrementing wrong register.  New firmware fix ensures correct register is decremented.\n- Improve debug data collection during self-initiated resets."
    },
    {
      "id": "2142620e2c8d50ab1cb18380fc3fde53962851f2adaa2310acaf43d8362b33f5",
      "name": "Hynix 1.2.1 FW for PE9010 NVMe drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "version": "1.2.1",
      "release_id": "8X8YR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-08T07:02:51Z",
      "released": "2025-04-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12965378M/1/Express-Flash-PCIe-SSD_Firmware_8X8YR_WN64_1.2.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8X8YR",
      "size": 23487200,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.2.0 for Hynix PE9010 NVMe SSD drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, and HFS480GDJ8X167N.",
      "revision_history": "Fixes:\n\nFixes the DCTm layer that was introduced in 1.2.0 '  Pause MCTP for Error responsing Admin command (ex. Invalid Opcode, Prohibited Opcode..) when CIAP==1.\nChanged not to block MI command in reset service blocker.\nFix to treat FTL fail of, unattached address area, during DST as DSTR:6\nFixed smbus interrupt error case\nAdd NSSR to PanicResetAction\nSet PEL for control primitive resume with invalid param for CSI\n\"First packet received in multi packet\nMCTP Control message received with same tag.\nFirst message discard, but slot state (MI context) not clear.\"\nset NSSRO bit after panic reset\nClear MI GetState ErrorState Bits managed on HADM side when MCTP Endpoint reset.\nCheck DOFST field of MI admin commands before processing.\nSmart::updateControllerBusyTime bug fix\nreset number of queues during nvme reset\nAssert occurs during SPL in Panic Recovery\nFix DELL Incorrect TLA and ADellEMCUI default values\nPCIe correctable receiver error during NSSR"
    },
    {
      "id": "83664d939c9cfb8526c53484a2553d46f8499432e5077ee7074fc0f9d30e0827",
      "name": "Firmware GA09 Update for Longspeak SATA ISE HDD.  Model numbers: ST18000NM008D-3DL133 \u0026 ST20000NM008D-3DJ133",
      "version": "GA09",
      "release_id": "R02JH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-27T09:48:50Z",
      "released": "2025-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12915495M/1/Serial-ATA_Firmware_R02JH_WN64_GA09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R02JH",
      "size": 24250208,
      "reboot_required": false,
      "description": "Firmware Update for Longspeak SATA ISE HDD.  Model numbers: ST18000NM008D-3DL133 \u0026 ST20000NM008D-3DJ133.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Servo code change to address single stage actuator resonance issue in high vibe environment\n- Various performance improvements."
    },
    {
      "id": "184134c1a1ecf8858631bf182a7044b3ff1922ae6a878fe9c4f89795a41a6902",
      "name": "Seagate GS09 Firmware Update for Longspeak SAS ISE HDD.  Model numbers: ST18000NM007D \u0026 ST20000NM004D",
      "version": "GS09",
      "release_id": "WCTTD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-27T09:41:56Z",
      "released": "2025-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12915397M/1/SAS-Drive_Firmware_WCTTD_WN64_GS09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WCTTD",
      "size": 24555296,
      "reboot_required": false,
      "description": "Firmware Update for Longspeak SAS ISE HDD.  Model numbers: ST18000NM007D \u0026 ST20000NM004D.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Servo code change to address single stage actuator resonance issue in high vibe environment\n- Various performance improvements."
    },
    {
      "id": "1a8d0cae34f34673f3b4b00e11c9afb0dd6c336159ff4731f389b80feed0f007",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 ISE Firmware Release",
      "version": "1.0.2",
      "release_id": "NHM72",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-13T00:49:07Z",
      "released": "2025-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12850528M/1/Express-Flash-PCIe-SSD_Firmware_NHM72_WN64_1.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NHM72",
      "size": 30929456,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any RHEL and Ubuntu OS. Either use Windows SLES or iDRAC for FW update - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "134f9d13a2951baa0261de65e929e12f75351064111f853eed8ca1e7ba179f07",
      "name": "Firmware Update for Toshiba MG10 SAS. Model Number MG10SCA20TEY",
      "version": "EN04",
      "release_id": "0H3CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-11T14:39:14Z",
      "released": "2025-03-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12841970M/1/SAS-Drive_Firmware_0H3CX_WN64_EN04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0H3CX",
      "size": 24586112,
      "reboot_required": false,
      "description": "Firmware Update for Toshiba MG10 SAS.  Model Number MG10SCA20TEY.\nAdded command to update Adjacent Track Interference settings, and improved the drive retry processing.",
      "revision_history": "Fixes:\nAdded UART Command to change ATI (Adjacent Track Interference) Enable/Disable settings.\nFurther strengthened the retry process as a countermeasure against false hard error detection.\nAdded retry processing as a countermeasure against the false detection of hard errors.\nMultiple performance enhancements."
    },
    {
      "id": "5bdddd1d8557db43989a33ba11ce36bc1dd41874116c02b65d9bb1d605696706",
      "name": "Seagate CimarronBP SAS FIPS for LT0E FW for Model numbers: ST8000NM022B",
      "version": "LT0E",
      "release_id": "4T1MM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-06T06:42:36Z",
      "released": "2025-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12816183M/1/SAS-Drive_Firmware_4T1MM_WN64_LT0E_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4T1MM",
      "size": 24932568,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS FIPS 512e HDD.  Model number: ST8000NM022B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "c5d54c034608aea2b30ae772d2f1f626db4814ccac68e55449f6043dcf90ab77",
      "name": "HGST RT09 for Vela-AP SATA ISE model number(s) HUS728T8TALE6L0",
      "version": "RT09",
      "release_id": "T0RX4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T09:40:40Z",
      "released": "2024-04-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025871M/1/Serial-ATA_Firmware_T0RX4_WN64_RT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T0RX4",
      "size": 13355792,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SATA HDD, Model number HUS728T8TALE6L0.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "7be90932a9eca915194db12b4b54c6e2d1dfaf50ecc4c79c27b1761682ea45d0",
      "name": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "version": "2.5.0",
      "release_id": "4P5K1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-07-03T13:05:39Z",
      "released": "2024-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11804735M/1/Express-Flash-PCIe-SSD_Firmware_4P5K1_WN64_2.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4P5K1",
      "size": 7724464,
      "reboot_required": false,
      "description": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "revision_history": "Fixes:\n\n- FW introduces multiple fixes and enhancements."
    },
    {
      "id": "57c906ff5507962cafb5c3c783d13f06921a3b3fc05d0d6ba692520b4090e167",
      "name": "Seagate ST37 for model number(s) ST600MM0069 and ST1200MM0099.",
      "version": "ST37",
      "release_id": "C161G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-29T10:13:00Z",
      "released": "2023-07-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09844732M/3/SAS-Drive_Firmware_C161G_WN64_ST37_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C161G",
      "size": 13245848,
      "reboot_required": false,
      "description": "This release contains firmware version ST36 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error hapepends during a head switch with RAW enabled."
    },
    {
      "id": "67853bdae5f8f83316b8093431448ef64ab284feb1b58cea3b0eaa7e3c004854",
      "name": "Toshiba GD05 for MG08 Air SATA 4TB program for model number(s) MG08ADA400NY.",
      "version": "GD05",
      "release_id": "F73C5",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-08T08:33:43Z",
      "released": "2024-01-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11347964M/1/Serial-ATA_Firmware_F73C5_WN64_GD05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F73C5",
      "size": 12767200,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba GD05 for MG08 Air SATA 4TB program for model number(s) MG08ADA400NY",
      "revision_history": "Fixes:\n'- Improves performance in ECS systems\n- Improves performance for random access workloads\n- Firmware addresses several corner case bugs in error handling scenarios\n- Firmware implements several internal process optimizations and enhancements"
    },
    {
      "id": "9d1c1564008221f1f7a7c85b77df4c49bc728867b7bffb5361e743e9f19ed7b9",
      "name": "Seagate SBW5 for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "version": "SBW5",
      "release_id": "9KWMD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-26T11:29:43Z",
      "released": "2023-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09947108M/2/SAS-Drive_Firmware_9KWMD_WN64_SBW5_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9KWMD",
      "size": 13258560,
      "reboot_required": false,
      "description": "This release contains firmware version SBW5 Seagate for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled."
    },
    {
      "id": "6c992026ccb1034e5d76c43933dc44c2595da3c48f49b380535843c14de95847",
      "name": "Micron K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "version": "K003",
      "release_id": "RJ0WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T14:41:30Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606437M/2/Serial-ATA_Firmware_RJ0WY_WN64_K003_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJ0WY",
      "size": 12627936,
      "reboot_required": false,
      "description": "This release contains firmware version K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "revision_history": "Fixes:\n\n-Fixes to address performance."
    },
    {
      "id": "7f5691c4430c7327b0a80ce3ef83995daadc50336c7a6a3a67edf9b560b1db34",
      "name": "Micron K403 for 5400 SATA model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB",
      "version": "K403",
      "release_id": "JTW3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T06:58:14Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606566M/2/Serial-ATA_Firmware_JTW3W_WN64_K403_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTW3W",
      "size": 12364032,
      "reboot_required": false,
      "description": "This release contains firmware version K403 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB.",
      "revision_history": "Fixes:\n\n- Fixes to address performance."
    },
    {
      "id": "af718bba045a1770880a3798635bd2970568b875f053f212b6a59895db94ec42",
      "name": "HGST MU03 for model number(s) HUS722T2TALA600 and HUS722T1TALA600.",
      "version": "MU03",
      "release_id": "V3DJM",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:51:43Z",
      "released": "2018-08-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05040482M/6/Serial-ATA_Firmware_V3DJM_WN64_MU03_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3DJM",
      "size": 12145288,
      "reboot_required": false,
      "description": "This release contains firmware version MU03 for HGST drives. Vendor model numbers HUS722T2TALA600 and HUS722T1TALA600.",
      "revision_history": "Fixes\n- Fix for an possible interrupt during Dell factory process during repeated I/O commands.\n\nEnhancements\nn/a"
    },
    {
      "id": "7befc05c945f5c3f654ebd22984277341f826f5c59d0f9290977ad0b4488cfa7",
      "name": "Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "version": "EK06",
      "release_id": "GTG81",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-17T06:10:13Z",
      "released": "2024-01-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11140543M/1/SAS-Drive_Firmware_GTG81_WN64_EK06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GTG81",
      "size": 12131264,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "revision_history": "Fixes:\n- Addresses an issue that could cause occasional read errors"
    },
    {
      "id": "29723a24d6277fbd5dc76380b92bea3fb5b475ba6941cf5d84e0d6ea658d6414",
      "name": "This release contains firmware version CSFC for STX drives. Vendor model numbers ST8000NM010A.",
      "version": "CSFC",
      "release_id": "39G15",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-03-17T10:30:21Z",
      "released": "2022-03-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08334869M/1/SAS-Drive_Firmware_39G15_WN64_CSFC_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=39G15",
      "size": 11380760,
      "reboot_required": false,
      "description": "This release contains firmware version CSFB for STX drives. Vendor model numbers ST8000NM010A.",
      "revision_history": "Fixes:\nFix issues that can cause IOEDC errors.\nMake one step download from the initial release code work.\nEnhancements:\nImprove performance for certain workloads\nEnhance sense code reporting accuracy\nIncreased BMS interval timer value"
    },
    {
      "id": "ca7a1185d66c28a9b74be9322021bfc822d17d9186b6130ec5b3aef279eb0ab1",
      "name": "WD Paris-C SAS FIPS firmware UM06 for model number WUH721816AL5205",
      "version": "UM06",
      "release_id": "DNC5D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-03-03T09:21:18Z",
      "released": "2022-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08277672M/1/SAS-Drive_Firmware_DNC5D_WN64_UM06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DNC5D",
      "size": 12487520,
      "reboot_required": false,
      "description": "Initial release of WDC Paris-C SAS FIPS firmware version UM06 for model number WUH721816AL5205.",
      "revision_history": "Fixes:\n-Initial release\n\nEnhancements:\n-Initial release"
    },
    {
      "id": "65645d5857702dfa62b35234f1f242791911d0ebba5aa55060456d258e81d3bb",
      "name": "Toshiba FK5D for model number(s) TOSHIBA MG04ACA100NY, TOSHIBA MG04ACA200NY and TOSHIBA MG04ACA400NY.",
      "version": "FK5D",
      "release_id": "V47C4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-07-14T07:08:33Z",
      "released": "2020-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06400316M/1/Serial-ATA_Firmware_V47C4_WN64_FK5D_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V47C4",
      "size": 10624128,
      "reboot_required": false,
      "description": "This release contains firmware version FK5D for Toshiba drives. Vendor model numbers TOSHIBA MG04ACA100NY, TOSHIBA MG04ACA200NY and TOSHIBA MG04ACA400NY.",
      "revision_history": "Fixes:\nSeek algorithm adjusted to reduces spikes in acoustic levels leading to audible noise concerns.\nDEFT algorithm modified to ensure drives with modified seek algorithm will still pass DEFT testing.\n\nEnhancements:\nN/A"
    }
  ]
}