  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r4715",
  "name": "R4715",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R4715 Express Flash PCIe SSD Updates",
  "filter": "express-flash-pcie-ssd",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 11,
      "rss": "/r4715/urgent/rss.xml",
      "api": "/api/r4715/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 60,
      "rss": "/r4715/recommended/rss.xml",
      "api": "/api/r4715/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 20,
      "rss": "/r4715/optional/rss.xml",
      "api": "/api/r4715/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r4715/bios/rss.xml",
      "api": "/api/r4715/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r4715/boss/rss.xml",
      "api": "/api/r4715/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r4715/chipset/rss.xml",
      "api": "/api/r4715/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r4715/diagnostics/rss.xml",
      "api": "/api/r4715/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r4715/drivers-for-os-deployment/rss.xml",
      "api": "/api/r4715/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 17,
      "rss": "/r4715/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r4715/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/r4715/firmware/rss.xml",
      "api": "/api/r4715/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r4715/idrac/rss.xml",
      "api": "/api/r4715/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 10,
      "rss": "/r4715/network/rss.xml",
      "api": "/api/r4715/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 26,
      "rss": "/r4715/sas-drive/rss.xml",
      "api": "/api/r4715/sas-drive"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 7,
      "rss": "/r4715/sas-raid/rss.xml",
      "api": "/api/r4715/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 23,
      "rss": "/r4715/serial-ata/rss.xml",
      "api": "/api/r4715/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 1,
      "rss": "/r4715/systems-management/rss.xml",
      "api": "/api/r4715/systems-management"
    }
  ],
  "count": 17,
  "updates": [
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "f0477d83411396c5aa41dc093b6f87c193db3f8a49b4276a1d829a96500bfa3e",
      "name": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.2",
      "release_id": "17R29",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-05-12T10:07:15Z",
      "released": "2026-05-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14538090M/1/Express-Flash-PCIe-SSD_Firmware_17R29_WN64_2.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17R29",
      "size": 27203048,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8 U.2 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Upon detecting SMBDAT is stuck in low state, a bus clear is performed to release the low state.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "2576d421636e87b519086721087196201ac74ebd37755dce4f70eb579e503d8d",
      "name": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release Maintenance Firmware",
      "version": "1.3.1",
      "release_id": "N78NP",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-03-03T19:47:31Z",
      "released": "2026-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14259015M/1/Express-Flash-PCIe-SSD_Firmware_N78NP_WN64_1.3.1_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N78NP",
      "size": 27170488,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 7500 U.2 ISE Firmware Release - Maintenance Firmware",
      "revision_history": "Fixes:  \n\n1. Improved the firmware to ensure internal PCIe register access is done according to the specification.\n2. Updated the firmware to add SCL detection/protection\n3. Improved firmware to detect the noise on power rail.\n4. Improved firmware to add detection/protection for incomplete Host-Initiated Data Transfer\n5. Improved firmware to add detection/protection for drive Initialization with Poor PCIe Signal Integrity\n6. Improved firmware to add detection and initiate rest/recovery operation to the power management controller upon power on.\n7. Updated the firmware to prevent the deadlock scenario while extended Host Idle Time (no SSD device I/O)\n8. Updated the firmware to Enable PCIe relaxed ordering\n\nEnhancements:  \nN/A"
    },
    {
      "id": "d2e853f3f5a847f2ac69e20f6a50ee0c8c13d7f51ebea7fce622736a421738ac",
      "name": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release",
      "version": "1.3.0",
      "release_id": "VNYK2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-01-08T16:07:20Z",
      "released": "2025-11-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14055051M/1/Express-Flash-PCIe-SSD_Firmware_VNYK2_WN64_1.3.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VNYK2",
      "size": 32458088,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release"
    },
    {
      "id": "cca5695e4a8e61074fdc1de3a322725393df6e48f8498fa5f2dd6e2c301186f7",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "71KRG",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-12-16T18:48:47Z",
      "released": "2025-09-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13990425M/1/Express-Flash-PCIe-SSD_Firmware_71KRG_WN64_1.2.0_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=71KRG",
      "size": 29639544,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Improvements to drive internal logging.\n2. Improvements to SMART logging and notification.\n3. Resolved sideband firmware download issue.\n\nEnhancements:\n\n1. Additional support added for firmware update for Dell 17th generation servers.\n2. Additional support added for firmware update for Dell PERC 12 and 13 controllers."
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "bea393cd7ed560d3796bfa29c286b2bb04388bf5fa9367772361a83d468eee66",
      "name": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release",
      "version": "1.6.0",
      "release_id": "4XT8T",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-08-20T03:25:15Z",
      "released": "2025-01-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12287992M/4/Express-Flash-PCIe-SSD_Firmware_4XT8T_WN64_1.6.0_A02_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4XT8T",
      "size": 27769424,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash P5316 ISE Firmware Release for Powerscale ONLY"
    },
    {
      "id": "d7118a4011a988e2e951915d1cc298925ca524ddf11d30cbbcda0b4011e70320",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.4.0",
      "release_id": "TVCWT",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-07-11T04:31:50Z",
      "released": "2025-07-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13369867M/1/Express-Flash-PCIe-SSD_Firmware_TVCWT_WN64_1.4.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TVCWT",
      "size": 29064896,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo be added"
    },
    {
      "id": "59399b6ce0f13bd5649446151ad7d9a072c6d8c70f4a2f7abe335ef870bbace4",
      "name": "Dell Express Flash NVMe PCIe SSD 6500 U.2 ISE Firmware Release",
      "version": "1.1.0",
      "release_id": "NRKF4",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T07:30:48Z",
      "released": "2024-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12096577M/2/Express-Flash-PCIe-SSD_Firmware_NRKF4_WN64_1.1.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NRKF4",
      "size": 29254888,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 6500 U.2 ISE Firmware Release",
      "revision_history": "Fixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "94586f99bddb6d07e51ebf78479fa5de5fb353777dec7e7bb0b73c704b3c21bf",
      "name": "Dell Datacenter NVME RI AGN ISE",
      "version": "1.1.1",
      "release_id": "XMFKX",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:50:32Z",
      "released": "2024-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12037085M/2/Express-Flash-PCIe-SSD_Firmware_XMFKX_WN64_1.1.1_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XMFKX",
      "size": 30415680,
      "reboot_required": false,
      "description": "Dell Datacenter NVME RI AGN ISE",
      "revision_history": "Fixes:\n\n1. Updated DUP framework for 17G server platforms."
    },
    {
      "id": "7b5443856ba19be3fec98045af7c451979d66ce96d52fa3076856936318d3249",
      "name": "Dell Datacenter NVMe RI AG ISE",
      "version": "1.1.0",
      "release_id": "TDGKY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-06-20T11:09:41Z",
      "released": "2024-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12324309M/2/Express-Flash-PCIe-SSD_Firmware_TDGKY_WN64_1.1.0_A02_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TDGKY",
      "size": 31845152,
      "reboot_required": false,
      "description": "Dell Datacenter NVMe RI AG ISE",
      "revision_history": "Fixes:\n\nEnhancements:\n\n1. Implementation of the latest Eye Opening Measurement specfication (TP4119a).\n2. Enable support for Eye Opening Measurement (PCLMT) Tool version 3.2.7."
    },
    {
      "id": "20bf714b8e559377da3eab75736f36b9641946091085d1475a770d95de77f284",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "version": "3.0.4",
      "release_id": "8T6F8",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-16T12:34:15Z",
      "released": "2025-05-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13259395M/1/Express-Flash-PCIe-SSD_Firmware_8T6F8_WN64_3.0.4_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8T6F8",
      "size": 29998824,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 FIPS Firmware Maintenance Release",
      "revision_history": "Fixes:  \n\n1. When the reference clock is turned off after a PERET# assertion interrupt or a reference clock off interrupt, the CPU never accesses the MAC register until the PIPE clock is restored after PERST# de-assertion.\n2. PHY reset during Hot Reset or Link Disabled is not mandatory, so this process can be skipped. This measure shortens the transition time from Detect to Polling.Active from 70 ms to about 10 ms.\n3. Add flag to prevent DRAM Self Refresh from being triggered.\n4. Once a specific Block has been marked as a bad block that is not to be used, an erase error on the bad block will not cause the Block Erase operation to fail.\n5. The drive FW is modified to suspend the DMAC operation by the drive internal CPU for snapshot saving during the Low power transition.\n6. Fix the Max PE Cycle values mismatch issue for MU 12TB and RI 30TB\n\nEnhancements:  \nN/A"
    },
    {
      "id": "7d93b47a9d1b92fb19afd5ae11efa61fdc5a6d79b95659c25c9029fdba7db904",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "version": "2.0.3",
      "release_id": "K1JTM",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-13T21:13:35Z",
      "released": "2025-05-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13253883M/1/Express-Flash-PCIe-SSD_Firmware_K1JTM_WN64_2.0.3_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K1JTM",
      "size": 29789880,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 U.2 ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \n\n1. When the reference clock is turned off after a PERET# assertion interrupt or a reference clock off interrupt, the CPU never accesses the MAC register until the PIPE clock is restored after PERST# de-assertion.\n2. PHY reset during Hot Reset or Link Disabled is not mandatory, so this process can be skipped. This measure shortens the transition time from Detect to Polling.Active from 70 ms to about 10 ms.\n3. Add flag to prevent DRAM Self Refresh from being triggered.\n4. Once a specific Block has been marked as a bad block that is not to be used, an erase error on the bad block will not cause the Block Erase operation to fail.\n5. The drive FW is modified to suspend the DMAC operation by the drive internal CPU for snapshot saving during the Low power transition.\n6. Fix the Max PE Cycle values mismatch issue for MU 12TB and RI 30TB\n\nEnhancements:  \nN/A"
    },
    {
      "id": "2142620e2c8d50ab1cb18380fc3fde53962851f2adaa2310acaf43d8362b33f5",
      "name": "Hynix 1.2.1 FW for PE9010 NVMe drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, HFS480GDJ8X167N",
      "version": "1.2.1",
      "release_id": "8X8YR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-08T07:02:51Z",
      "released": "2025-04-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12965378M/1/Express-Flash-PCIe-SSD_Firmware_8X8YR_WN64_1.2.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8X8YR",
      "size": 23487200,
      "reboot_required": false,
      "description": "This release contains firmware version for 1.2.0 for Hynix PE9010 NVMe SSD drive program for model number(s) HFS1T9GDJ8X167N, HFS960GDJ8X167N, and HFS480GDJ8X167N.",
      "revision_history": "Fixes:\n\nFixes the DCTm layer that was introduced in 1.2.0 '  Pause MCTP for Error responsing Admin command (ex. Invalid Opcode, Prohibited Opcode..) when CIAP==1.\nChanged not to block MI command in reset service blocker.\nFix to treat FTL fail of, unattached address area, during DST as DSTR:6\nFixed smbus interrupt error case\nAdd NSSR to PanicResetAction\nSet PEL for control primitive resume with invalid param for CSI\n\"First packet received in multi packet\nMCTP Control message received with same tag.\nFirst message discard, but slot state (MI context) not clear.\"\nset NSSRO bit after panic reset\nClear MI GetState ErrorState Bits managed on HADM side when MCTP Endpoint reset.\nCheck DOFST field of MI admin commands before processing.\nSmart::updateControllerBusyTime bug fix\nreset number of queues during nvme reset\nAssert occurs during SPL in Panic Recovery\nFix DELL Incorrect TLA and ADellEMCUI default values\nPCIe correctable receiver error during NSSR"
    },
    {
      "id": "1a8d0cae34f34673f3b4b00e11c9afb0dd6c336159ff4731f389b80feed0f007",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 U.2 ISE Firmware Release",
      "version": "1.0.2",
      "release_id": "NHM72",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-13T00:49:07Z",
      "released": "2025-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12850528M/1/Express-Flash-PCIe-SSD_Firmware_NHM72_WN64_1.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NHM72",
      "size": 30929456,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 U.2 ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any RHEL and Ubuntu OS. Either use Windows SLES or iDRAC for FW update - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "7be90932a9eca915194db12b4b54c6e2d1dfaf50ecc4c79c27b1761682ea45d0",
      "name": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "version": "2.5.0",
      "release_id": "4P5K1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-07-03T13:05:39Z",
      "released": "2024-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11804735M/1/Express-Flash-PCIe-SSD_Firmware_4P5K1_WN64_2.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4P5K1",
      "size": 7724464,
      "reboot_required": false,
      "description": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "revision_history": "Fixes:\n\n- FW introduces multiple fixes and enhancements."
    }
  ]
}