  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r350",
  "name": "R350",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R350 Updates",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 44,
      "rss": "/r350/urgent/rss.xml",
      "api": "/api/r350/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 109,
      "rss": "/r350/recommended/rss.xml",
      "api": "/api/r350/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 37,
      "rss": "/r350/optional/rss.xml",
      "api": "/api/r350/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r350/bios/rss.xml",
      "api": "/api/r350/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/r350/chipset/rss.xml",
      "api": "/api/r350/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r350/diagnostics/rss.xml",
      "api": "/api/r350/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r350/drivers-for-os-deployment/rss.xml",
      "api": "/api/r350/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 5,
      "rss": "/r350/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r350/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 2,
      "rss": "/r350/firmware/rss.xml",
      "api": "/api/r350/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r350/idrac/rss.xml",
      "api": "/api/r350/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 22,
      "rss": "/r350/network/rss.xml",
      "api": "/api/r350/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 73,
      "rss": "/r350/sas-drive/rss.xml",
      "api": "/api/r350/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 10,
      "rss": "/r350/sas-non-raid/rss.xml",
      "api": "/api/r350/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 12,
      "rss": "/r350/sas-raid/rss.xml",
      "api": "/api/r350/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 57,
      "rss": "/r350/serial-ata/rss.xml",
      "api": "/api/r350/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r350/systems-management/rss.xml",
      "api": "/api/r350/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/r350/video/rss.xml",
      "api": "/api/r350/video"
    }
  ],
  "count": 190,
  "updates": [
    {
      "id": "837f52bcdf77c2d14310498f7dd4952e13c37aa4c6fdc01265b9a428e061657d",
      "name": "Dell EMC iDRAC Service Module Installer for OS DUP, v6.2.0.0",
      "version": "6.2.0.0",
      "release_id": "JDJH3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-11-09T07:17:23Z",
      "released": "2026-10-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15095008M/5/Systems-Management_Application_JDJH3_WN64_6.2.0.0_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDJH3",
      "size": 34422592,
      "reboot_required": false,
      "description": "iDRAC Service Module (iSM) is a lightweight software service that better integrates operating system (OS) features with iDRAC and can be installed on Dell PowerEdge 15G and above servers. iSM provides OS-related information to iDRAC and adds capabilities such as Lifecycle Controller log event replication into the OS log, iDRAC SNMP alerts via OS, iDRAC hard reset and remote full Power Cycle. iSM has very little impact on the host processor and smaller memory footprint, thus expanding iDRAC management to the supported host operating systems.",
      "revision_history": "NA"
    },
    {
      "id": "76245d0a584c5ccc82e289fc13f517d6fe16339b10aa85c49a062f45e8a4f53d",
      "name": "DELL System Update, v.2.3.0.2",
      "version": "2.3.0.2",
      "release_id": "RDVR3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-11-06T11:10:35Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213121M/1/Systems-Management_Application_RDVR3_WN64_2.3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RDVR3",
      "size": 30983200,
      "reboot_required": false,
      "description": "DELL System Update (DSU) is a software designed to facilitate the application of updates on various Dell systems. Using DSU you can:\n1.Identify the available updates, select the relevant updates, and deploy the updates on multiple systems.\n2.Maintain consistency in terms of interface and versions across Operating Systems, Repositories, and Systems.",
      "revision_history": "Enhancement :\n\nOS native support with passthrough and rsystemtype iDRAC \n\nFixes :\n\nSecurity Issues"
    },
    {
      "id": "441f01efc24fdb35921daa676e2ee39d68fa1f5699a3621c00dad8bbe0709096",
      "name": "Dell Server PowerEdge BIOS R350/R250/T350/T150 Version 1.18.3",
      "version": "1.18.3",
      "release_id": "NY16D",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-11-06T03:27:20Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15211345M/2/BIOS_NY16D_WN64_1.18.3.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NY16D",
      "size": 39624024,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced features sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Enhancements\n- This product release contains security update DSA-2026-470, DSA-2026-471. Any security fix information will be accessible on the Dell Security Advisories and Notices website."
    },
    {
      "id": "8aa76a35b653e3c7dd881c37055a45e7ab11264f2f4df6d16bf2a8f6042d8cab",
      "name": "Dell HBA355e Adapter Controller Firmware",
      "version": "40.15.12.00",
      "release_id": "6DGJX",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T09:40:24Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15196334M/2/SAS-Non-RAID_Firmware_6DGJX_WN64_40.15.12.00_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6DGJX",
      "size": 29068584,
      "reboot_required": true,
      "description": "This package contains the Dell HBA355e Adapter controller firmware update.",
      "revision_history": "Fixes\n======\nFixed a task management fault that could occur during storage device discovery.\n\nEnhancements\n============\n\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "07b730186cf34b21f1bc6a7e367bb4f20ff4674b7da109ef4ff816c20807afae",
      "name": "Dell HBA350i Adapter Controllers Firmware",
      "version": "40.15.12.00",
      "release_id": "DKF49",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T09:40:23Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15196399M/2/SAS-Non-RAID_Firmware_DKF49_WN64_40.15.12.00_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DKF49",
      "size": 27712000,
      "reboot_required": true,
      "description": "This package contains the Dell HBA350i Adapter controller firmware update.",
      "revision_history": "Fixes\n======\nFixed a task management fault that could occur during storage device discovery.\n\nEnhancements\n============\n\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "d1c5dc2befc0dd7ba8acac2d340945c700554d6e16f2c200d0d063c33cefe4af",
      "name": "Dell HBA355i Front/Adapter \u0026 HBA350i MX Controller Firmware",
      "version": "40.15.12.00",
      "release_id": "TNHXM",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-04T09:35:16Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15196262M/2/SAS-Non-RAID_Firmware_TNHXM_WN64_40.15.12.00_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TNHXM",
      "size": 30424208,
      "reboot_required": true,
      "description": "This package contains the Dell HBA355i Front/Adapter \u0026 HBA350i MX controller firmware update.",
      "revision_history": "Fixes\n======\nFixed a task management fault that could occur during storage device discovery.\n \nEnhancements\n============\n\nOptimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "f3bebb0ea076c51f997c39c2e6f089cb17182bde69506e404e14db5e263708a6",
      "name": "Windows Server 2025 Driver for HBA11 Controllers",
      "version": "2.61.94.0",
      "release_id": "M52NC",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-03T07:37:47Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15197458M/1/SAS-Non-RAID_Driver_M52NC_WN64_2.61.94.0_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M52NC",
      "size": 17870184,
      "reboot_required": true,
      "description": "This release updates Windows 2025 Server driver for HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter \u0026 MX Controllers.",
      "revision_history": "Fixes\n=====\n\nFixed added to change some system log events from error level to warning.\n\nEnhancements\n============\n\nNone"
    },
    {
      "id": "485852249ce96798798a4c9033ecbe07faa1fb52e45044f4c5ef80ba9dd9b517",
      "name": "Windows Server 2022 Driver for HBA11 Controllers",
      "version": "2.61.94.0",
      "release_id": "JP0MF",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-03T06:44:55Z",
      "released": "2026-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15197058M/1/SAS-Non-RAID_Driver_JP0MF_WN64_2.61.94.0_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JP0MF",
      "size": 17856960,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver for HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter \u0026 MX controllers",
      "revision_history": "Fixes\n=====\n\nFixed added to change some system log events from error level to warning.\n\nEnhancements\n============\n\nNone"
    },
    {
      "id": "fd0732c1a5436e1e87e2f3b578749cbde7f0ad1acade4f2c68a4395a4ec03d68",
      "name": "iDRAC 7.30.65.51",
      "version": "7.30.65.51",
      "release_id": "77JC4",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-26T15:08:42Z",
      "released": "2026-10-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15169022M/1/iDRAC-with-Lifecycle-Controller_Firmware_77JC4_WN64_7.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=77JC4",
      "size": 244930552,
      "reboot_required": false,
      "description": "The Integrated Dell Remote Access Controller (iDRAC) is designed to make server administrators more productive and improve the overall availability of Dell servers. iDRAC also provides an out-of-band mechanism for configuring the platform, applying firmware updates, saving or restoring a system backup, or deploying an operating system, either by using a GUI or a remote scripting language, such as Redfish or RACADM.",
      "revision_history": "Fixes:\n- Fixes the issue where email alert is not enabled for LCS0009 event on PowerEdge XE8640 systems.\n- Fixes the issue where RAC1195 events for local user account deletion are missing in iDRAC9 releases by instrumenting the user deletion endpoint to generate audit logs.\n- Fixes the issue where Active Directory authentication fails due to DNS Type = ANY by changing the DNS query from T_ANY to T_SRV to comply with RFC8482.\n- Fixes the issue where CPU throttling occurs when PSU power input drops on PowerEdge T550 systems since iDRAC 7.20.30.00 by addressing the power FTR loop issue.\n- Fixes the issue where firmware update notifications on homepage use cached recommended updates by addressing the deletion of lc_validator_output.xml during iDRAC reboot or system erase operation.\n- Fixes the issue where fan failures occur on PowerScale R660 nodes after firmware updates by addressing the timing issue between BIOS updates and fan initialization.\n\nEnhancements:\n- Made Subject Alternative Name (SAN) mandatory for SSL/TLS CSR generation in iDRAC9.\n- Upgraded Poky for iDRAC9 16G.\n- Upgraded kernel to version 6.12.63 for iDRAC9 16G.\n- Added SMTP modern authentication (OAuth2) support for iDRAC9 16G.\n- Added TPM PCR Measurements reporting in Redfish for iDRAC9.\n- Added new option \"LCLOG\" in SystemErase for clearing LC logs without host reboot.\n- Added China Data Sanitization Compliance with Block Erase support on drives via iDRAC for 16G.\n- Leveraged iDRAC Early Video for Services Modernization on 16G.\n- Optimized 16G CPLD Firmware Update for Services Modernization.\n- Implemented correct and reliable Redfish StartUpdate action for 16G.\n- Enabled optional auto deletion of completed/failed iDRAC Jobs for 16G.\n- Enabled CPLD and iDRAC firmware updates with a single iDRAC reboot for 16G.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior for 16G.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message for 16G.\n- Added Leak Warranty Void Warning Message support for iDRAC platforms 16G.\n- Updated OID for SCV replacement certificate on 16G/15G platforms.\n- Added security (firmware) assertions from iDRAC9 to SCV certificate.\n- Added iDRAC persistence and reconciliation capability for SCV Delta Certificate upload synchronization.\n- Enabled email alerts for thermal-related GPU/TMP events for 16G.\n- Enabled iLKM support on PowerEdge XR8620t.\n- Added Microsoft Entra ID (formerly Azure AD) support for OpenID Connect for 16G.\n- Migrated iDRAC9 GUI from AngularJS to Angular Framework for 16G.\n- Addressed Channel Firmware SED integration and stability issues for 16G.\n- Updated Redfish specification and schema for the 16G March release.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification for iDRAC9.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero Touch Bootstrap for 16G.\n- Fixed BootProgress/LastState property value showing as \"OSRunning\" when the server is not booted to the operating system.\n- Improved SEKM key retrieval retry and logging.\n- Added iDRAC uptime to sysinfo for 16G.\n- Added GetBIOSTime functionality and SetBIOSTime handling for unsupported BIOS for 16G.\n- Exposed Redfish APIs for Hardware Configuration Validation control in iDRAC for 16G.\n- Added support for SID/OPAL/PSID drive status property.\n- Added SDPM Battery Inventory and BBU Replacement Behavior for 16G."
    },
    {
      "id": "318fefd2743ce3a042428d9e8d722b8a862af777cc9df710c689ecd125c66516",
      "name": "Broadcom NetXtreme-E Network Device Firmware (Dell) 23.8.1",
      "version": "38.11.91.00",
      "release_id": "H3TR4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-10-13T23:36:18Z",
      "released": "2026-10-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15122845M/1/Network_Firmware_H3TR4_WN64_38.11.91.00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3TR4",
      "size": 84351360,
      "reboot_required": false,
      "description": "This release provides updated network controller firmware for the Broadcom NetXtreme-E devices.   This release should be used with the Broadcom NetXtreme-E 23.8 device drivers."
    },
    {
      "id": "2784cac0b8b58ea70ad630208898d6eb97e9b03ca201d3538f7cdf540045f1b2",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N",
      "version": "1.3.1",
      "release_id": "VMDWF",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:48Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652186M/3/Express-Flash-PCIe-SSD_Firmware_VMDWF_WN64_1.3.1_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VMDWF",
      "size": 28699000,
      "reboot_required": true,
      "description": "Hynix 1.3.1 FW for PE90X0 NVMe OPAL drive program for model number HFS480GEJ8X176N, HFS800GEJ8X176N, HFS960GEJ8X176N.",
      "revision_history": "Fixes: \n\nFW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "a9017f3140289b317e112d789c28482d6226881bc8dd0e05c58dc4640963ca51",
      "name": "MICRON 5200 RI/ MU SATA \u0026apos;F006\u0026apos; FW for model number(s) MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, MTFDDAK1T9TDN, MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD",
      "version": "F006",
      "release_id": "DJFFV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T13:57:57Z",
      "released": "2026-06-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14570492M/2/Serial-ATA_Firmware_DJFFV_WN64_F006_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DJFFV",
      "size": 26417352,
      "reboot_required": false,
      "description": "This release contains Micron firmware F006 for models MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD, MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, and MTFDDAK1T9TDN for all operating systems.",
      "revision_history": "LogEntryCnt = 65,535 \n- Exit the workload log function directly; no workload log entry is recorded.\nLogEntryCnt = 0 to 65,534\n- Workload log recording continues as originally designed."
    },
    {
      "id": "ddd0e2c51b4580eb2778870b68324d237a03ac014aa8e6f1d071efa03f75333c",
      "name": "BOSS-S2 Firmware",
      "version": "2.5.13.4009",
      "release_id": "TTR5R",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-25T07:01:26Z",
      "released": "2023-02-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09232098M/7/SAS-RAID_Firmware_TTR5R_WN64_2.5.13.4009_A01_06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TTR5R",
      "size": 22410088,
      "reboot_required": true,
      "description": "BOSS-S2 ROM version 2.5.13.4009",
      "revision_history": "Fixes:\n\n-- Addressed false M.2 failures reported due to thermal issues \n               \nEnhancements:\n-- Added new SDID 0x2261 on BOSS-S2 controller"
    },
    {
      "id": "2100af4e9173bdff79684c91aba38c704677dabc553c7215357fc544f34ae220",
      "name": "Dell OS Driver Pack",
      "version": "25.04.03",
      "release_id": "RY43K",
      "category": "Drivers for OS Deployment",
      "category_slug": "drivers-for-os-deployment",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-09-15T05:49:55Z",
      "released": "2025-05-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13060523M/3/Drivers-for-OS-Deployment_Application_RY43K_WN64_25.04.03_A01_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RY43K",
      "size": 35156056,
      "reboot_required": false,
      "description": "OS Driver Pack for PowerEdge 15G servers. This Driver Pack contains applicable storage and embedded LOM drivers to support OS installation using the Dell Lifecycle Controller",
      "revision_history": "N/A"
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "dbcfb5f8d4ca05fbd05677da4e2f7ab6b9a14ce9ea98e71643d928f51d2df178",
      "name": "PERC H355 RAID Controller Firmware",
      "version": "52.38.0-6897",
      "release_id": "V39Y1",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-08T05:38:01Z",
      "released": "2026-08-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14921744M/3/SAS-RAID_Firmware_V39Y1_WN64_52.38.0-6897_A07_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V39Y1",
      "size": 30032768,
      "reboot_required": true,
      "description": "This package contains an update to PERC H355 RAID controller firmware",
      "revision_history": "Fixes\n=========\n  - Fix added to ignore the extra 3 bytes in the MCTP command with payload when wrong byte count field set in I2C header.\n  - Fixed drive firmware download metadata is not cleared until the last drive is finished updating.\n  - Fixed an issue where PL fault E40E observed with Switch attached topology. \n  - Fixed an issue where incorrect SATA Request Sense response for drive in active power condition by Clear the standby flag when start stop unit command is sent to SATA drive with start operation.\n  - Fixed an issue to log the link speed change event only if there is an actual change in speed.\n  - Fixed an issue to avoid starting a time for host IO in command block request when the controller is not operational yet.\n  - Fixed an issue where Predictive failure drive's DDF is not cleared after completing the copy back operation to global hot spare. \n  - Fixed an issue where Data Abort exception was observed during concurrent I/O operations, drive hot-plug, and UBM firmware update operations.\n  - Fixed an issue where Enabled column in storcli /cx/lnall show does not show disabled when the phy is marked unstable and disabled\n  - Fixed an issue where Firmware hits an exception, while converting JBODs to unconfigure state\n  - Fixed an issue where Controller fault 431E observed while running all phy off on test. \n  - Fixed an issue where SATA SMR Report Zone data not swapped correctly in some cases. \n  - Fixed an issue where Out of bound array access are restricted by additional conditional checks before accessing enclosure and drive related arrays.\n  - Fixed an issue where wrong patrol read resume event message after power cycle\n  - Added check condition checks and validation to prevent the buffer overflow during RDE drive enumeration.\n  - Fixed added when MCTP I2C OOB Communication Fails to Recover from a Malformed Packet.\n  - Added a fix for the Drive Security error that occurs when no drives are connected.\n  \nEnhancements/Tasks\n======================\n - Optimizations and Improvements from Static Code Analysis."
    },
    {
      "id": "448ded191420b195668e21a896d8e278e90683ea41473b713cb91404b90354bf",
      "name": "Broadcom NetXtreme network device firmware (Dell), 23.8",
      "version": "23.81.6",
      "release_id": "6W3WV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-08T03:06:44Z",
      "released": "2026-09-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14991490M/2/Network_Firmware_6W3WV_WN64_23.81.6.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6W3WV",
      "size": 22772392,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for Broadcom NetXtreme devices.  This release should be used with the Broadcom 23.8 device drivers."
    },
    {
      "id": "4175d48092d0c8309e216153c7b743dbea59b1590da4dedc03c2970bca816070",
      "name": "MICRON 5100 max Pro RI/ Pro boot M.2 SATA \u0026apos;L013\u0026apos; FW for model number(s) MTFDDAV240TCB, MTFDDAV480TCB, MTFDDAV960TCB, MTFDDAV1T9TCB, MTFDDAK240TCB, MTFDDAK480TCB, MTFDDAK960TCB, MTFDDAK1T9TCB",
      "version": "L013",
      "release_id": "RTND5",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-04T14:23:56Z",
      "released": "2026-08-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14983889M/1/Serial-ATA_Firmware_RTND5_WN64_L013_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RTND5",
      "size": 26470688,
      "reboot_required": true,
      "description": "This release contains firmware version L013 for MICRON model number(s) MTFDDAV240TCB, MTFDDAV480TCB, MTFDDAV960TCB, MTFDDAV1T9TCB, MTFDDAK240TCB, MTFDDAK480TCB, MTFDDAK960TCB, MTFDDAK1T9TCB.  Capacity of 5100 max Pro boot 240GB, 480GB, 960GB, 1.92TB. Pro RI 240GB, 480GB, 960GB and 1.92TB",
      "revision_history": "Fixes:\n1. D0DL013 addresses this issue.  The updated behavior will be:\n2. LogEntryCnt = 65,535 Exit the workload log function directly; no workload log entry is recorded.\n3. LogEntryCnt = 0 to 65,534 Workload log recording continues as originally designed."
    },
    {
      "id": "40a5d823af38ca2ebe7cbf8287901fe09aafe6fca47e6048df8429e0f104815d",
      "name": "Microsoft Windows x64 management driver for BOSS",
      "version": "1.2.0.1052",
      "release_id": "8KKVC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-31T12:12:02Z",
      "released": "2021-07-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07524633M/9/SAS-RAID_Driver_8KKVC_WN64_1.2.0.1052_A02_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8KKVC",
      "size": 17014984,
      "reboot_required": false,
      "description": "Microsoft Windows x64 management driver for BOSS",
      "revision_history": "Fixes: None,\nEnhancements: YES , Signed Binaries\nConsole Management Driver for all Windows Operating systems\nSupport for Windows Azure HCI Stack \u0026 Windows 2022 enabled"
    },
    {
      "id": "e030fecbf94eb9512ae1dfa4fb776046fd4612d06268cb14e6909c5d697489ae",
      "name": "BOSS-S1 Modular firmware",
      "version": "2.6.13.3025",
      "release_id": "F9F16",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-27T11:07:40Z",
      "released": "2023-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09214778M/11/SAS-RAID_Firmware_F9F16_WN64_2.6.13.3025_A08_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F9F16",
      "size": 23542872,
      "reboot_required": true,
      "description": "BOSS-S1 Modular ROM version 2.6.13.3025",
      "revision_history": "Fixes : HW Re-spin \nAddressed false M.2 failures reported due to thermal issues\n\nEnhancements : Added new SDID 0x2260 on BOSS-S1 controller"
    },
    {
      "id": "0a6a479d8442052f0ed7ecbee39b76740eab0e8b746a305ff6194e3d7220e695",
      "name": "Seagate Evans Firmware Version ESLA  for model number(s)  ST10000NM011G, ST12000NM009G, ST14000NM013G,ST16000NM010G",
      "version": "ESLA",
      "release_id": "T16JN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-10T04:27:32Z",
      "released": "2026-08-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14878500M/1/SAS-Drive_Firmware_T16JN_WN64_ESLA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T16JN",
      "size": 27626464,
      "reboot_required": false,
      "description": "Firmware Update of \"ESLA\" for Evans SAS ISE HDD.  Model numbers: ST10000NM011G, ST12000NM009G, ST14000NM013G, and ST16000NM010G.",
      "revision_history": "- FW change to address potential Drive Assert by updating the cleanup logic to handle the interrupted write data frame when the host queue happens to be active during termination cleanup sequence."
    },
    {
      "id": "05aaf2787b94f4c3658352e334d92a069cdbd2bc57150c8d9513a2190745fc22",
      "name": "This release contains firmware version CSLF for STX drives. Vendor model numbers ST6000NM035A, ST8000NM014A.",
      "version": "CSLF",
      "release_id": "C4W12",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-10T04:01:33Z",
      "released": "2026-08-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14878306M/1/SAS-Drive_Firmware_C4W12_WN64_CSLF_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C4W12",
      "size": 27698568,
      "reboot_required": false,
      "description": "Firmware Refresh of \"CSLF\" for Seagate Cimarron 512e ISE.  Vendor model number ST6000NM035A, ST8000NM014A.",
      "revision_history": "- FW change to address potential Drive Assert by updating the cleanup logic to handle the interrupted write data frame when the host queue happens to be active during termination cleanup sequence."
    },
    {
      "id": "2cfb5d1f16ddc7672fb89251188bf188d61b25334440ba70289057a49c93cf2c",
      "name": "Intel NIC Family Version 25.0 Drivers for Windows 64-bit Operating Systems",
      "version": "25.0.0",
      "release_id": "J99NN",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-04T00:23:11Z",
      "released": "2026-08-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14855482M/1/Network_Driver_J99NN_WN64_25.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J99NN",
      "size": 53939904,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt."
    },
    {
      "id": "64c3b0521b620435ff6f16d6e050214f67b7fbe7f3a70d5205394e41833db3a9",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.8",
      "version": "23.81.0",
      "release_id": "RNT70",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:51:28Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843705M/1/Network_Driver_RNT70_WN64_23.81.0_238.1.170.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RNT70",
      "size": 14747512,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "e383c232a59d867730c67aff93fece1f8bb4e33d1f8f1d0795276821d80c6740",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.8 update.",
      "version": "38.11.70.00",
      "release_id": "X9DJG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:44:02Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843656M/2/Network_Driver_X9DJG_WN64_38.11.70.00_238.1.170.0_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9DJG",
      "size": 17265544,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "7a614f2dd02a71f7264337b85eb55d6adcb4d0302e69a8d71ab2c7eae29d15bf",
      "name": "PERC H755 RAID Controller firmware version 52.30.0-6753",
      "version": "52.30.0-6753",
      "release_id": "N6C86",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-06-02T16:27:30Z",
      "released": "2026-06-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14615957M/4/SAS-RAID_Firmware_N6C86_WN64_52.30.0-6753_A11_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N6C86",
      "size": 32673752,
      "reboot_required": true,
      "description": "PERC H755 RAID Controller firmware version 52.30.0-6753",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions, including Single Bit Errors (SBE) and Multi Bit Errors (MBE).\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown to power off the system, followed by a power on to enable the new memory settings.\nA warm reboot will NOT activate the updated settings.\nIf iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required."
    },
    {
      "id": "559e792d7369318d22be9a9b8c82cb7c3e6f91193952b11ebf8a9ba38e90ab7c",
      "name": "Toshiba EF0A for model number(s) AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY",
      "version": "EF0A",
      "release_id": "THG5M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T06:27:04Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607520M/2/SAS-Drive_Firmware_THG5M_WN64_EF0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=THG5M",
      "size": 26661096,
      "reboot_required": false,
      "description": "This release contains firmware version EF0A for Toshiba drives. Vendor model numbers AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures.\n- Fixed Command timeout (or 06/29/04) issue.\n  This problem may occur when the queued time for a read or write command \n  exceeds the Command Aging Timer and the SYNCHRONIZED CACHE \n  command is also queued.\n- Fixed random write iops degradation after sequential read.\n    4k Random write -\u003e Seq read -\u003e 4k random write. In this test sequence, \n    2nd 4k random write iops may drop.\n- Fixed a wrong LBA report in SENSE DATA when Read Buffer CRC \n    error(03/11/02) occurs."
    },
    {
      "id": "fdd84063aa261dc77f4bd896bc2458570e08fd9fa0f7c7a07d843154dbc72955",
      "name": "Initial release of Toshiba AL15SE+ HDD Model Number AL15SEB09EQY",
      "version": "EF82",
      "release_id": "VJWX0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T04:21:30Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607338M/2/SAS-Drive_Firmware_VJWX0_WN64_EF82_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJWX0",
      "size": 26660216,
      "reboot_required": false,
      "description": "This release contains firmware version EF82 for Toshiba drives. Vendor Model Number AL15SEB09EQY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures."
    },
    {
      "id": "03e8dec5c03adb6448e38d5f9b0b4125a9bb5df8f6d028557b2ca7607f6dc11e",
      "name": "Firmware Update for WDC London-DP SATA ISE Model Numbers WUH722420ALE600 \u0026 WUH722424ALE600.",
      "version": "YT05",
      "release_id": "TH00R",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T10:12:05Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14473938M/1/Serial-ATA_Firmware_TH00R_WN64_YT05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TH00R",
      "size": 25064600,
      "reboot_required": false,
      "description": "Firmware Update for WDC London-DP YT05 FW SATA ISE Model Numbers WUH722420ALE600 \u0026 WUH722424ALE600.",
      "revision_history": "- Fix for event when Drive hits self-initiated reset when we failed to retrieve write specs from the drive media cache.\n- Ensure model number and component ID report correctly when loading Server firmware on top of Storage firmware.\n- Fixes to improve Adjacent Track Interference handling.\n- Various other maintenance fixes and  enhancements.\n- Multiple firmware fixes to address self-initiated resets and additional maintenance updates."
    },
    {
      "id": "da12798b6da912db3532f166cafb20fb3ec549b473f15acc1a6362ac6c2de7c2",
      "name": "Firmware Update for WDC London-DP SAS ISE Model Numbers WUH722420AL5200 \u0026 WUH722424AL5200.",
      "version": "YS05",
      "release_id": "N15JC",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T08:17:10Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14473291M/1/SAS-Drive_Firmware_N15JC_WN64_YS05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N15JC",
      "size": 24974832,
      "reboot_required": false,
      "description": "Firmware Update for WDC London-DP YS05 FW SAS ISE Model Numbers WUH722420AL5200 \u0026 WUH722424AL5200.\n.",
      "revision_history": "- Fix for event when Drive hits self-initiated reset when we failed to retrieve write specs from the drive media cache.\n- Ensure model number and component ID report correctly when loading Server firmware on top of Storage firmware.\n- Fixes to improve Adjacent Track Interference handling.\n- Various other maintenance fixes and enhancements.\n- Multiple firmware fixes to address self-initiated resets and additional maintenance updates."
    },
    {
      "id": "1649cedd050f14c96f8903133c79a26b7f90719920c7fbde0a1ff66c7d8db1b9",
      "name": "Firmware update for WDC Paris-CP SATA ISE Model Numbers: WUH722012CLE600, WUH722016CLE600",
      "version": "AT06",
      "release_id": "36JH0",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T07:23:32Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14472919M/1/Serial-ATA_Firmware_36JH0_WN64_AT06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=36JH0",
      "size": 22781784,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP AT06 FW SATA ISE Model Numbers: WUH722012CLE600, WUH722016CLE600.",
      "revision_history": "- Firmware update to ensure the 512e Dell Model string and Dell Device ID will not show correctly when Server code is loaded over Storage code.\n- FW fix to ensure Background Media Scan timer is reset correctly when Offline Data Collection is started.\n- Code updated to ensure Component ID and Model string will report correctly after firmware upload."
    },
    {
      "id": "14646318eed9bac1cd8e2b6564c5b3f136a7e60b8437700c0a1d1dfa05775f75",
      "name": "Firmware update for WDC Paris-CP SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200",
      "version": "AS06",
      "release_id": "XTC10",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T06:13:54Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14472580M/1/SAS-Drive_Firmware_XTC10_WN64_AS06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XTC10",
      "size": 22713344,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP  AS06 FW SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200.",
      "revision_history": "- Firmware update to ensure the 512e Dell Model string and Dell Device ID will not show correctly when Server code is loaded over Storage code.\n- FW fix to ensure Background Media Scan timer is reset correctly when Offline Data Collection is started.\n- Code updated to ensure Component ID and Model string will report correctly after firmware upload."
    },
    {
      "id": "832f358867a87dbab42fc379e286da1d8bd7b8fd87d614862be22df1da90058d",
      "name": "Hynix SE5130 DG02 Firmware for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N",
      "version": "DG02",
      "release_id": "17C3M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-03-09T14:43:52Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14279570M/1/Serial-ATA_Firmware_17C3M_WN64_DG02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17C3M",
      "size": 25675424,
      "reboot_required": true,
      "description": "This is the initial firmware release of HYNIX, SE5130, DG02 for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N.",
      "revision_history": "Fixes:\n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "c9b41b21cbbcb00bd5365d004fa23c5cfc5886c7562f50846076b5e00df72bcf",
      "name": "Intel NIC Family Version 25.0.0 Firmware for Intel I350 and X550 Adapters",
      "version": "25.0.4",
      "release_id": "HMDDR",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-02-12T15:08:34Z",
      "released": "2026-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14205749M/2/Network_Firmware_HMDDR_WN64_25.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HMDDR",
      "size": 23253664,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.X on Intel I350 and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.X on Intel I350 and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "f90cc54712c96fa90b3d686e1a364c9add6a13f9467ab55c5b33f3095b0ab102",
      "name": "Intel NIC Family Version 25.0.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "25.0.4",
      "release_id": "PJDHV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-02-12T14:50:50Z",
      "released": "2026-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14205977M/2/Network_Firmware_PJDHV_WN64_25.0.4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PJDHV",
      "size": 46329512,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 25.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "See the fw_release_x710.txt file for more information."
    },
    {
      "id": "109fb6b95e4f17a3406ee60a0fd9f5f182f10aecad84d73f05b068cd4eb379bb",
      "name": "Toshiba GD06 for MG08 Air SATA 4TB program for model number(s) MG08ADA400NY.",
      "version": "GD06",
      "release_id": "NK38K",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-21T16:35:13Z",
      "released": "2026-01-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14115387M/1/Serial-ATA_Firmware_NK38K_WN64_GD06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NK38K",
      "size": 22451512,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba GD06 for MG08 Air SATA 4TB program for model number(s) MG08ADA400NY",
      "revision_history": "- Adjusted the algorithm to prioritize read commands when the ratio of queued write commands is high.\n- Added log version information to the header section of the Health management log.\n- Refactored the code to add new internal functions.\n- Added firmware fix to prioritize read commands when the ratio of queued write commands is high."
    },
    {
      "id": "9fd6affe37d428e75f2e8db5e95c5ad5dd42698079c34de94e37e76eaaf4f4ba",
      "name": "Toshiba MG08AD SATA ISE drive program for GE04 FW for model number(s): MG08ADA800EY",
      "version": "GE04",
      "release_id": "2HN47",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-21T16:18:53Z",
      "released": "2026-01-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14115298M/1/Serial-ATA_Firmware_2HN47_WN64_GE04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2HN47",
      "size": 22472928,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG08AD SATA ISE.  Model number MG08ADA800EY.",
      "revision_history": "- Adjusted the algorithm to prioritize read commands when the ratio of queued write commands is high.\n- Added log version information to the header section of the Health management log.\n- Refactored the code to add new internal functions.\n- Added firmware fix to prioritize read commands when the ratio of queued write commands is high."
    },
    {
      "id": "dae0461c34b8e9b05e2103cd7c6f1818ef1a06ec6fc2604c7b4a09bcbd88295b",
      "name": "Toshiba MG08AC SATA ISE drive program for GC05 FW for model number(s): MG08ACA16TEY.",
      "version": "GC05",
      "release_id": "3FWPH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-01-13T03:19:09Z",
      "released": "2025-12-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13964523M/3/Serial-ATA_Firmware_3FWPH_WN64_GC05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3FWPH",
      "size": 22626664,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG08 SATA ISE.  Model number MG08ACA16TEY.",
      "revision_history": "Several issue fixes, including prioritizing read commands when the ratio of queued write commands is high.\n- Adjusted the algorithm to prioritize read commands when the ratio of queued write commands is high.\n- Changed the write data transfer conditions so that Hold Primitive does not occur.\n- Fixed an issue where the write command of the large sector is processed after the read command, causing an Timeout error report."
    },
    {
      "id": "02286d72f669c005452804c6682322adb99d5abb1748762b5742f8ed0eacaeb9",
      "name": "Samsung HK58 FW for PM897a SATA drive program for model number(s) MZ7L3480HELTAD3, MZ7L3960HELAAD3, MZ7L31T9HENAAD3, MZ7L33T8HENAAD3",
      "version": "HK58",
      "release_id": "V5XNY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T15:24:01Z",
      "released": "2025-09-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13895112M/1/Serial-ATA_Firmware_V5XNY_WN64_HK58_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V5XNY",
      "size": 23609288,
      "reboot_required": true,
      "description": "This update includes optimizations to reset handling, log collections, and SMART attribute handling.  Version HK58 firmware for Samsung PM897a SATA SSDs, models MZ7L3480HELT-00AD3,  MZ7L3960HELA-00AD3,  MZ7L31T9HENA-00AD3,  MZ7L33T8HENA-00AD3.",
      "revision_history": "Fixes:\n\n- Altered Reset handling to respond to all COMRST commands within 1 sec.\n- Altered DRAM allocation for live dumps, to eliminate FW assert due to max. allocation count\n- Eliminated debug log check during Open, to eliminate fake UECC written during DTT shutdown\n\nEnhancement:\n\n- Changed SMART Attributes 173, 175, and 177 to Advisory."
    },
    {
      "id": "e846d6c1ff5659ce2b77ca6d67f8125ae920ef3bc41f09ffce056334e4fc547b",
      "name": "This release contains firmware version HL58 for supplier model number(s) MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "version": "HL58",
      "release_id": "D5D3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T15:19:35Z",
      "released": "2025-09-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13895080M/1/Serial-ATA_Firmware_D5D3W_WN64_HL58_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D5D3W",
      "size": 23613616,
      "reboot_required": true,
      "description": "This update includes optimizations to reset handling, log collections, and SMART attribute handling.  Version HL58 firmware for Samsung PM893a SATA SSDs, models  MZ7L3960HELT-00AD3,  MZ7L31T9HELA-00AD3,  MZ7L33T8HELA-00AD3, MZ7L37T6HELA-00AD3.",
      "revision_history": "Fixes: \n\n- Altered Reset handling to respond to all COMRST commands within 1 sec.\n- Altered DRAM allocation for live dumps, to eliminate FW assert due to max. allocation count\n- Eliminated debug log check during Open, to eliminate fake UECC written during DTT shutdown\n\nEnhancement:\n\n- Changed SMART Attributes 173, 175, and 177 to Advisory."
    },
    {
      "id": "c73beccb3d67ad1b365735cea9aefae76310134df79570616d77bd8f290f431d",
      "name": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205",
      "version": "AM05",
      "release_id": "HTW37",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T10:16:13Z",
      "released": "2025-11-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13893761M/1/SAS-Drive_Firmware_HTW37_WN64_AM05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HTW37",
      "size": 25081440,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205.\nCode updated to fix potential issue during Dell Factory Test.",
      "revision_history": "Firmware update to address potential issue during Dell Enhanced Factory Test."
    },
    {
      "id": "19e4e741289fa377d8952ffbe882abe72120f68c9c5e74a51cbecf29719adba9",
      "name": "Hynix SE5031 (ISE MU) DD03 Firmware for model number(s) HFS480G32FEH-BA10A, HFS960G32FEH-BA10A, HFS1T9G32FEH-BA10A, HFS3T8G32FEH-BA10A.",
      "version": "DD03",
      "release_id": "174WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-12T10:51:25Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13855287M/1/Serial-ATA_Firmware_174WY_WN64_DD03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=174WY",
      "size": 26478904,
      "reboot_required": true,
      "description": "This release contains firmware version for Hynix SE5031 (ISE MU) DD03 Firmware model number(s) HFS480G32FEH-BA10A, HFS960G32FEH-BA10A, HFS1T9G32FEH-BA10A, HFS3T8G32FEH-BA10A.",
      "revision_history": "Fixes: \n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "dbdfbff4fda3b33a0f47c4f2c9593f17f3ce0e05b9698b3ff06a66b44465d1ae",
      "name": "Hynix SE5110 ISE RI DZ04 Firmware for model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N",
      "version": "DZ04",
      "release_id": "HFTMG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-11-12T10:51:19Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13855285M/1/Serial-ATA_Firmware_HFTMG_WN64_DZ04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HFTMG",
      "size": 26870384,
      "reboot_required": true,
      "description": "This release contains initial firmware DZ04 for Hynix SE5110 ISE. Model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N.",
      "revision_history": "Fixes: \n\nFix1: Add a sequence to clear the \"\"health monitoring done bit\"\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while."
    },
    {
      "id": "7fd7af210790eda1f74415dd2f34089d430c7df10a5b4f14bc700d31e45d055a",
      "name": "Samsung PM883a RI SSDR, FW HG61 for model number(s) MZ7LH240HBHQAD3, MZ7LH480HBHQAD3, MZ7LH960HBJRAD3, MZ7LH1T9HALTAD3, MZ7LH3T8HALTAD3, and MZ7LH7T6HALAAD3.",
      "version": "HG61",
      "release_id": "3GHD6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-11-10T14:08:33Z",
      "released": "2025-09-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13842682M/1/Serial-ATA_Firmware_3GHD6_WN64_HG61_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3GHD6",
      "size": 23504296,
      "reboot_required": true,
      "description": "This update includes optimizations to reset handling, log collections, and SMART attribute handling. Version HG61 firmware for Samsung PM883a SATA SSDs, models MZ7LH240HBHQAD3,MZ7LH480HBHQAD3,MZ7LH960HBJRAD3,MZ7LH1T9HALTAD3,MZ7LH3T8HALTAD3,and MZ7LH7T6HALAAD3.",
      "revision_history": "Fixes:\n\n- Altered Reset handling to respond to all COMRST commands within 1 sec.\n- Altered DRAM allocation for live dumps, to eliminate FW assert due to max. allocation count.\n\nEnhancements:\n\n- Changed SMART Attributes 173, 175, and 177 to Advisory."
    },
    {
      "id": "76e7ada98d033dda19e13f8cee07dec5f65a42f60d2ea730a362f843cd46487e",
      "name": "Toshiba GF08 for MG09 SATA ISE model number(s) MG09ACA18TEY, MG09ACA16TEY, and MG09ACA12TEY",
      "version": "GF08",
      "release_id": "KMTGF",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-10-21T08:59:24Z",
      "released": "2025-10-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13765916M/1/Serial-ATA_Firmware_KMTGF_WN64_GF08_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KMTGF",
      "size": 23525440,
      "reboot_required": false,
      "description": "FW update for of Toshiba MG09 SATA ISE.  Model numbers MG09ACA18TEY, MG09ACA16TEY, and MG09ACA12TEY.\nFix for a Background Medium Scan issue and potential timeout.",
      "revision_history": "- Fixed a problem during Background Medium Scan or Drive Self-test in which a long read with command interrupt disabled was performed under certain conditions and other commands could not be executed.\n- Fixed the issue that could cause a SCT timeout response to fail after Flush Cache Command.\n- Fixed the issue that write commands are abnormally executed two times internally and cause BCRC error or SATA I/F protocol error."
    },
    {
      "id": "b9c46d96040d3002cf5c44f7e7ab2a9b4fa8590564eb834f2797f02925f4e35a",
      "name": "FW update for of Toshiba MG09 SAS ISE.  Model numbers MG09SCA18TEY, MG09SCA16TEY, and MG09SCA12TEY",
      "version": "EM06",
      "release_id": "20Y02",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-10-21T05:49:55Z",
      "released": "2025-10-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13764807M/1/SAS-Drive_Firmware_20Y02_WN64_EM06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=20Y02",
      "size": 23534880,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG09 SAS ISE.  Model numbers MG09SCA18TEY, MG09SCA16TEY, and MG09SCA12TEY.\nFix for a Background Medium Scan issue and potential timeout.",
      "revision_history": "- Fixed a problem during Background Medium Scan or Drive Self-test in which a long read with command interrupt disabled was performed under certain conditions and other commands could not be executed.\n- Fixed the issue that could cause a SCT timeout response to fail after Flush Cache Command.\n- Fixed the issue that write commands are abnormally executed two times internally and cause BCRC error or SATA I/F protocol error."
    },
    {
      "id": "18db910ff4ed477c8296e6b844189a18134ef2fec5793433edea50ab24ff9ea6",
      "name": "Non-Expander Storage Backplane Firmware for Select PowerEdge Platforms",
      "version": "7.16",
      "release_id": "5DV1W",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-10-10T17:59:05Z",
      "released": "2025-10-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13712463M/6/Firmware_5DV1W_WN64_7.16_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5DV1W",
      "size": 22774896,
      "reboot_required": false,
      "description": "Passive SEP Backplane Firmware for 15th Generation PowerEdge 1U and select XE and XR Systems",
      "revision_history": "Firmware 7.16\n\nFixes:\n- None\n\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\n\nChange History:\n\nFirmware 7.10\nFixes:\n- Addressed a potential backplane issue where some slot descriptor values are not correctly initialized which could prevent the storage controller and/or hard drives from being displayed in the iDRAC Storage inventory.\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 6.97\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 3.72\nFixes:\n- Corrected issue with false drive detection in unpopulated slots\nEnhancements:\n- None\n\nFirmware 3.67\nFixes:\n- None\nEnhancements:\n- Added support for for new PowerEdge storage configurations.\n\nFirmware 3.57\nFixes:\n- Minor bug fixes\nEnhancements:\n- Added support for for new PowerEdge storage configurations.\n\nFirmware 3.56\nFixes:\n- Minor bug fixes\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 3.48\nFixes:\n- Minor bug fixes\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 3.43\nFixes:\n- Minor bug fixes\nEnhancements:\n- Added support for additional PowerEdge platforms, new storage configurations and backplanes.\n\nFirmware 3.04\nFixes:\n- Minor bug fixes\nEnhancements:\n- Enables PCIe Gen4 speeds for NVMe devices.\n- Adds support for new PowerEdge storage configurations.\n\nFirmware 2.84\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 2.41\nFixes:\n- Fixed a condition where the backplane could hang during drive hot-plug.\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 2.30\n- Initial Release"
    },
    {
      "id": "3735b6b54fcf04cd59cca7137654bb59c8fcdefecff53476ea296922b2fd6175",
      "name": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\nFW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.",
      "version": "PV10",
      "release_id": "8R6W6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-25T09:20:50Z",
      "released": "2025-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13676887M/1/Serial-ATA_Firmware_8R6W6_WN64_PV10_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8R6W6",
      "size": 23949896,
      "reboot_required": false,
      "description": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\n'FW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.\nIncludes FW update to add recognition of 2TB SATA capacity part number",
      "revision_history": "FW update to add Dell Part Number for newly added 2TB capacity"
    },
    {
      "id": "ea458c1dc12923103402934995464872ef26674afa20f185adc4120635d38acd",
      "name": "Samsung PM893 SATA SSDs for HJ64 firmware for models MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3",
      "version": "HJ64",
      "release_id": "T3HX9",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-18T15:53:37Z",
      "released": "2025-08-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652326M/1/Serial-ATA_Firmware_T3HX9_WN64_HJ64_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T3HX9",
      "size": 24511256,
      "reboot_required": true,
      "description": "This update includes critical changes to address PDL failures and SMART attribute reporting, along with enhancements to reduce  Version HJ64 firmware for Samsung PM893 SATA SSDs, models MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3.",
      "revision_history": "Fixes:\n- Altered exception handling to trigger SWI for all exceptions, to address the PDL issue.\n- Changed SMART attributes 173, 175, and 177 to Warning from Pre-Failure to match Dell specification.\n- Changed live dump DRAM allocation procedure to create a new each cycle, to eliminate FW assert / Error Mode due to DRAM threshold limit exceeded.\n- Fixed data mismatch caused by back-to-back SCT commands by flushing data to NAND befor each SCT command.\nEnhancements: \n- Allow Secure Erase command in Error Mode.\n- Enable extended Sequential Write check, to maintain sequential workload with few random commands included."
    },
    {
      "id": "0a1488415dc0e94ad9aeb1cbe1f7f5c3bc14a09653439f7d43842c0c70961d57",
      "name": "Samsung PM897 SATA SSDs for HH64 firmware for models MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "version": "HH64",
      "release_id": "VRG4Y",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-18T15:48:14Z",
      "released": "2025-08-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652260M/1/Serial-ATA_Firmware_VRG4Y_WN64_HH64_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VRG4Y",
      "size": 24507344,
      "reboot_required": true,
      "description": "This update includes critical changes to address PDL failures and SMART attribute reporting, along with enhancements to reduce  Version HH64 firmware for Samsung PM897 SATA SSDs, models MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3.",
      "revision_history": "Fixes:\n- Altered exception handling to trigger SWI for all exceptions, to address PDL issue.\n- Changed SMART attributes 173, 175, and 177 to Warning from Pre-Failure to match Dell specification.\n- Changed live dump DRAM allocation procedure to create new each cycle, to eliminate FW assert / Error Mode due to DRAM threshold limit exceeded.\n- Fixed data mismatch caused by back-to-back SCT commands by flushing data to NAND befor each SCT command.\nEnhancements: \n- Allow Secure Erase command in Error Mode.\n- Enable extended Sequential Write check, to maintain sequential workload with few random commands included."
    },
    {
      "id": "b0662e0dcea48ec11fc02672748c18c4038ef58e28c60e92dd1cc21b8f8d6bde",
      "name": "Toshiba MG08SD SAS ISE drive program for EL02 FW for model number(s): MG08SDA800EY",
      "version": "EL02",
      "release_id": "F95CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-09-03T09:09:09Z",
      "released": "2025-09-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13580189M/1/SAS-Drive_Firmware_F95CX_WN64_EL02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F95CX",
      "size": 23279080,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG08SD SAS ISE.  Model number MG08SDA800EY.\nFix for a Background Medium Scan issue and potential timeout.",
      "revision_history": "- Fixed a problem during Background Medium Scan or Drive Self-test in which a long read with command interrupt disabled was performed under certain conditions and other commands could not be executed.\n - Fixed the issue that could cause a SCT timeout response to fail after Flush Cache Command.\n - Fixed the issue that write commands are abnormally executed two times internally and cause BCRC error or SATA I/F protocol error."
    },
    {
      "id": "c4bf141c6378349d3febc74b35f5a3024900e88e5afeb3a1a67d0c554248998e",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.1 update.",
      "version": "23.11.16.21",
      "release_id": "8YWJY",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-20T03:19:10Z",
      "released": "2024-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12155596M/4/Network_Driver_8YWJY_WN64_23.11.16.21_231.1.162.1_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8YWJY",
      "size": 14278288,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- Stop 0x133 blue screen on Windows Azure Stack HCI.\n\nEnhancements:\n- none."
    },
    {
      "id": "f0c7c33f6a4f201f2f057bdb96f86911a0ec0cd66093d0e463fd502f62819caf",
      "name": "Firmware Update for EvansBP SATA ISE HDD.  Model numbers: ST12000NM002J-2TY133, ST14000NM002J-2TX133, ST16000NM002J-2TW133, ST18000NM002J-2TV133\n\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing",
      "version": "PALB",
      "release_id": "4MPD6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T15:57:45Z",
      "released": "2025-01-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12476257M/4/Serial-ATA_Firmware_4MPD6_WN64_PALB_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4MPD6",
      "size": 23564640,
      "reboot_required": false,
      "description": "This package contains firmware version PALB for Seagate drives (vendor Model numbers: ST12000NM002J-2TY133, ST14000NM002J-2TX133, ST16000NM002J-2TW133, ST18000NM002J-2TV133)",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command\n- Fix for potential assert during Write Uncorrectable testing\n- Shorten time delay before running Direct Offline Scan"
    },
    {
      "id": "45228c5635928cde92a1f46643d5a35b22ba672a72066d533bdcab54789eec75",
      "name": "Seagate CimarronBP SATA for LA0C FW for model number(s) ST8000NM023B",
      "version": "LA0C",
      "release_id": "P183W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:18:01Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12645613M/4/Serial-ATA_Firmware_P183W_WN64_LA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P183W",
      "size": 23711856,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SATA ISE 512e HDD.  Model number: ST8000NM023B-2TJ133.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for drive returning good status on a download that was interrupted with a link reset.\n- Fix for potential assert during IO test while looping writesame command."
    },
    {
      "id": "41d8ddf307b4ef32924e88af9618acf8165484bb258955e0c6381fffd74cec21",
      "name": "Seagate SBTA for Skybolt ServoBP program for model number(s) CL2400MM0149",
      "version": "SBTA",
      "release_id": "HH6J1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:02:18Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12677112M/2/SAS-Drive_Firmware_HH6J1_WN64_SBTA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HH6J1",
      "size": 23874432,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512n ISE. Model Number CL2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "4c6ed6166ab2e1a3e699af648e5457cd81edd18f87e2beea7561f7262fa1fa6d",
      "name": "Seagate SBSA for Skybolt ServoBP program for model number(s) BL2400MM0159",
      "version": "SBSA",
      "release_id": "00P56",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:22:58Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676520M/2/SAS-Drive_Firmware_00P56_WN64_SBSA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=00P56",
      "size": 23874416,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512e ISE.  Model Number BL2400MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "b3756f56e76fb6fdf6d53d9bc0bb41fa37aaf9ec858ba959301334044cd538e7",
      "name": "DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR",
      "version": "DL7C",
      "release_id": "VJPKG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-08-19T07:07:49Z",
      "released": "2025-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12600340M/4/Serial-ATA_Firmware_VJPKG_WN64_DL7C_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJPKG",
      "size": 22988728,
      "reboot_required": false,
      "description": "This is a firmware release for DELLSLDM Youngsville-RR  DL7C firmware for Model number(s) SSDSC2KB240GZR, SSDSC2KB480GZR, SSDSC2KB960GZR, SSDSC2KB019TZR, SSDSC2KB038TZR, SSDSC2KB076TZR, SSDSCKKB240GZR, SSDSCKKB480GZR,SSDSC2KG480GZR, SSDSC2KG960GZR, SSDSC2KG019TZR, SSDSC2KG038TZR",
      "revision_history": "Issue: During a warm Reboot the YVRR drive may intermittently disappear when connected to the PERC H965i\nFix: DL7C FW now addresses this issue\nIssue: PLI capacitor charge flag not set leads drive to enter disable logical mode\nFix: DL7C FW now addresses this issue"
    },
    {
      "id": "3327174b72088c6b72541588c503c14db0065a16884a08012949b2120919cf43",
      "name": "Seagate ST7G for model number(s) ST1800MM0159 and ST2400MM0159",
      "version": "ST7G",
      "release_id": "7N5DH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:05:15Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676236M/4/SAS-Drive_Firmware_7N5DH_WN64_ST7G_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7N5DH",
      "size": 23857864,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Skybolt 4Kn ISE.  Model Numbers ST2400MM0159 and ST1800MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "d5b4cea0b433c0dc5f334945213d8a951654857385c555988b21866cfaa38c0c",
      "name": "Firmware refresh for Seagate ST5J for model number(s) DL1800MM0159 and DL2400MM0159",
      "version": "ST5J",
      "release_id": "DRHV4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:02:48Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12671974M/4/SAS-Drive_Firmware_DRHV4_WN64_ST5J_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DRHV4",
      "size": 23857936,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512e ISE.  Model Numbers DL2400MM0159 and DL1800MM0159.",
      "revision_history": "Firmware modification to add support for new V8 NAND part."
    },
    {
      "id": "488b6d18b0e0ce3ac333ac5692fdf90c286b1f6fbbc6ac6a30f8212c5813f8ad",
      "name": "Firmware Update for EvansBP SAS ISE HDD. Model numbers: ST12000NM006J, ST14000NM006J, ST16000NM006J, ST18000NM006J",
      "version": "PSLG",
      "release_id": "XF65R",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:36:19Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12783645M/2/SAS-Drive_Firmware_XF65R_WN64_PSLG_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XF65R",
      "size": 23710648,
      "reboot_required": false,
      "description": "This release contains firmware version PSLG for Seagate drives. Vendor model numbers ST12000NM006J, ST14000NM006J, ST16000NM006J, ST18000NM006J.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Shorten time delay before running Direct Offline Scan"
    },
    {
      "id": "0c35e7ef25c69e2ab6c9f4c82eb0b9bba7107da2d604217f9dcd9d9848a86e2a",
      "name": "Seagate CimarronBP SAS ISE for FW LS0E for model numbers: ST8000NM024B",
      "version": "LS0E",
      "release_id": "FJ97K",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:32:22Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12816090M/2/SAS-Drive_Firmware_FJ97K_WN64_LS0E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FJ97K",
      "size": 24019096,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS ISE 512e HDD.  Model number: ST8000NM024B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "7de4851004c1bfeabb7fb64a8f7126fea032427318f4ed2b242114da8421a7be",
      "name": "Seagate CimarronBP SATA for FW LC0A for model numbers ST2000NM012B-2TD130, ST4000NM018B-2TF130",
      "version": "LC0A",
      "release_id": "T04YV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:22:43Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12638788M/2/Serial-ATA_Firmware_T04YV_WN64_LC0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T04YV",
      "size": 23567464,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SATA ISE 512n HDD.  Model numbers: ST2000NM012B-2TD130 and ST4000NM018B-2TF130\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for drive returning good status on a download that was interrupted with a link reset.\n- Fix for potential assert during IO test while looping writesame command."
    },
    {
      "id": "6b8fe0e8d91ff1271a42ada59a153ff6182e02d9af7e3d6ab2ede54b99a9287d",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.0",
      "version": "23.00.0",
      "release_id": "GJ9N4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-14T05:26:36Z",
      "released": "2024-09-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11901569M/3/Network_Driver_GJ9N4_WN64_23.00.0_230.1.116.0_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GJ9N4",
      "size": 14389968,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- BCM5719 missing Jumbo MTU and LSO options in Advanced Properties.\n\nEnhancements:\n- Add support for Windows Server 2025."
    },
    {
      "id": "dc8129f8e809b3ef0059b5776f5811a8bf3f8bfb75c0c5a365a994b47bd55d25",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.0 update.",
      "version": "23.01.11.60",
      "release_id": "FPMGT",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-13T09:16:08Z",
      "released": "2024-09-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11901574M/3/Network_Driver_FPMGT_WN64_23.01.11.60_230.1.116.0_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FPMGT",
      "size": 14640336,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for Windows Server 2025."
    },
    {
      "id": "79f5dca038dbfec6b6d5e08a95168ae2cb8849a86fefbc19fd111e821c9ecfb5",
      "name": "WDC Paris-C SATA ISE UT09 for model numbers WUH721816ALE6L0, WUH721818ALE6L0.",
      "version": "UT09",
      "release_id": "DK6P7",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-07-17T14:05:56Z",
      "released": "2025-07-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13397419M/1/Serial-ATA_Firmware_DK6P7_WN64_UT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DK6P7",
      "size": 25778688,
      "reboot_required": false,
      "description": "FW update for of  WDC Paris-C SATA ISE.  Model numbers WUH721816ALE6L0, WUH721818ALE6L0.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optiminum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "838387e0a28337097a14adabdc9607c0a6286c98d29f50a1e80938cbad0c708e",
      "name": "WDC Paris-C SAS ISE US09 for model numbers WUH721816AL5200, WUH721818AL5200",
      "version": "US09",
      "release_id": "GY6MD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-07-01T10:59:13Z",
      "released": "2025-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13323594M/1/SAS-Drive_Firmware_GY6MD_WN64_US09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GY6MD",
      "size": 25702128,
      "reboot_required": false,
      "description": "FW update for of  WDC Paris-C SAS ISE.  Model numbers WUH721816AL5200, WUH721818AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optiminum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "44256ed4fef1234a2e8759f3022799cf5ab23aef1ce176d84579f72db233e052",
      "name": "Firmware Update for Toshiba MG10.  Model Number MG10ACA20TEY.",
      "version": "GG03",
      "release_id": "KK671",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:35:49Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12199255M/4/Serial-ATA_Firmware_KK671_WN64_GG03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KK671",
      "size": 24534336,
      "reboot_required": false,
      "description": "Firmware Update for Toshiba MG10.  Model Number MG10ACA20TEY.\nModified Drive Selftest command functionality an changed Background Media Scan default to Enable.",
      "revision_history": "- Reduced the execution time of the Drive selftest command for offline drives.\n- Fixed a bug that would hang if a command was received immediately after starting Random Media Test.\n- Changed the default of Background Media Scan function to Enable."
    },
    {
      "id": "56221de0237fbeeb680e5eac2cb8d3e0f72799000d1986cf8fb68d7d02d297cd",
      "name": "Seagate SSEJ for model number(s) ST2400MM0149",
      "version": "SSEJ",
      "release_id": "KHJ9C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:13:51Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676334M/3/SAS-Drive_Firmware_KHJ9C_WN64_SSEJ_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHJ9C",
      "size": 24679816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512n ISE. Model Number ST2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "- Add support for Hynix V8 NAND part."
    },
    {
      "id": "ec564cb8c9f2124425b5f58e5f7dfcc480633219125075b2d358a0a31c167266",
      "name": "Dell 64 Bit uEFI Diagnostics, version 4303",
      "version": "4303A28",
      "release_id": "3GX21",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2025-06-19T06:56:52Z",
      "released": "2024-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12170967M/2/Diagnostics_Application_3GX21_WN64_4303A28_4303.28_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3GX21",
      "size": 9386600,
      "reboot_required": false,
      "description": "Dell Diagnostics are designed to verify proper operation of the hardware in your system outside of a high-level operating system environment. The files in this group can be used to update these diagnostics on a system with a Lifecycle Controller.",
      "revision_history": "This release contains minor bug fixes and enhancements."
    },
    {
      "id": "9af16c01a996600f0ca7ca41fae9ce3cd6a2c5aa191bd93b4454b7d2e7ed7fba",
      "name": "Western Digital Paris-D PR2 SAS VS19 firmware for model number WUH722020BL5200",
      "version": "VS19",
      "release_id": "XRFX3",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-19T13:58:09Z",
      "released": "2025-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13133280M/1/SAS-Drive_Firmware_XRFX3_WN64_VS19_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XRFX3",
      "size": 27819864,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-D PR2 SAS ISE.  Model number WUH722020AL5200.\nFW improvement to remove undesired self-initiated reset as a result of statistical counter overflow.",
      "revision_history": "Remove undesired self-initiated reset which could occur when large number of messages were sent since last power cycle"
    },
    {
      "id": "3a1ec62e9d91018b613e8a1f2d3d331fcf810f9a8958328c9acf8fbdc2ee855b",
      "name": "WD Paris -D  firmware VT19 for  Vendor model numbers WUH722020ALE600 and WUH722020BLE600",
      "version": "VT19",
      "release_id": "P09WG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-19T10:34:08Z",
      "released": "2025-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13132435M/1/Serial-ATA_Firmware_P09WG_WN64_VT19_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P09WG",
      "size": 27888568,
      "reboot_required": false,
      "description": "This release contains firmware version VT19 for WD Paris -D drives. Vendor model number WUH722020ALE600 and WUH722020BLE600. FW improvement to remove undesired self-initiated reset as a result of statistical counter overflow.",
      "revision_history": "Remove undesired self-initiated reset which could occur when large number of messages were sent since last power cycle"
    },
    {
      "id": "13a151274cafa129309ed8a49082115c0f3f92e553c15b9ed3bb5147905752ba",
      "name": "Western Digital WS03 for London-D SAS ISE model number(s) WUH722222AL5200",
      "version": "WS03",
      "release_id": "H9HD1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-13T07:04:13Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10293405M/7/SAS-Drive_Firmware_H9HD1_WN64_WS03_A00_06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H9HD1",
      "size": 27899456,
      "reboot_required": false,
      "description": "This release contains firmware version WS03 for Western Digital London-D SAS ISE drive WUH722222AL5200",
      "revision_history": "Fixes:\n\n- Fix for a self-initiated reset due to a race condition in updating a command block's next load during sequential dynamic attach.\n- Fix for a self-initiated reset by ensuring a hardware register bit is properly cleared."
    },
    {
      "id": "57d1b9e53e4d3a0c97675ee3421f8f74342a8583ce425e6b6b52cd30ecb7163d",
      "name": "This release contains firmware version EALA for STX model numbers ST10000NM005G-2MU133, ST12000NM005G-2MT133, ST14000NM005G-2KG133, and ST16000NM005G-2KH133",
      "version": "EALA",
      "release_id": "K4MNP",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-16T15:03:21Z",
      "released": "2025-04-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13003398M/2/Serial-ATA_Firmware_K4MNP_WN64_EALA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K4MNP",
      "size": 24391528,
      "reboot_required": false,
      "description": "This release contains firmware version EALA for STX model numbers ST10000NM005G-2MU133, ST12000NM005G-2MT133, ST14000NM005G-2KG133, and ST16000NM005G-2KH133.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Improve write latency performance when reading power conditions log."
    },
    {
      "id": "94cddbcf632ba8d62bf8fd89359de9b60c19a24649fa5a370ba55cb90e9ddaad",
      "name": "Seagate CimarronBP SAS for FW LW0B for model numbers ST2000NM013B, ST4000NM019B",
      "version": "LW0B",
      "release_id": "3P5N0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-16T09:10:59Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12648511M/2/SAS-Drive_Firmware_3P5N0_WN64_LW0B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3P5N0",
      "size": 24698960,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS ISE 512n HDD.  Model numbers: ST2000NM013B and ST4000NM019B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "d78097a304bc7f406875bbadbcca8c772491a0743210d472cd14ac2ffd491dd1",
      "name": "WD Paris-C SAS FIPS firmware UM08 for model number WUH721816AL5205,WUH721818AL5205",
      "version": "UM08",
      "release_id": "GY7F4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-15T08:50:10Z",
      "released": "2023-12-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10280782M/4/SAS-Drive_Firmware_GY7F4_WN64_UM08_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GY7F4",
      "size": 25600248,
      "reboot_required": false,
      "description": "Initial release of WDC Paris-C SAS FIPS firmware version UM08 for model number WUH721816AL5205,WUH721818AL5205",
      "revision_history": "Fixes:\n- Fix for potential hang condition caused by simultaneous 'set' and 'clear' settings in the request register bit.\n- Fix for drive not able to be recovered by format when it fails to read Logical to Physical address mapping data from disk.\nEnhancements:\n- Add Log Page 0x0D parameter 0x50."
    },
    {
      "id": "ceff23d80cbb8541baa365b1fd0640fa4a06d13481f5404c1fc5497f6dbd404c",
      "name": "Seagate SSC8 for model number(s) ST1200MM0069",
      "version": "SSC8",
      "release_id": "P9R4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:08:58Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11500432M/2/SAS-Drive_Firmware_P9R4D_WN64_SSC8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P9R4D",
      "size": 24522608,
      "reboot_required": false,
      "description": "This release contains firmware version SSC8 for Seagate drives. Vendor model numbers ST1200MM0069..",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "c2499ab3befc7f8aac45f1eb2b078813e866b63b701d8296d5628475a85b6e14",
      "name": "HGST NS11 for model number(s) HUH721212AL5200 and HUH721212AL4200",
      "version": "NS11",
      "release_id": "04PM5",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:07:34Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12029572M/2/SAS-Drive_Firmware_04PM5_WN64_NS11_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=04PM5",
      "size": 24602048,
      "reboot_required": false,
      "description": "This release contains firmware version NS11 for HGST drives. Vendor model numbers HUH721212AL5200 and HUH721212AL4200.\nFW update for WDC Leo-A 512e SAS HDD, Model number HUH721212AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes. \n'FW update for WDC Leo-A 4Kn SAS HDD, Model number HUH721212AL4200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "771aacec8b2f181d2931276a870acf035ada5af80f2174a808e8f6fe28a17150",
      "name": "HGST RS09 for Vela-AP SAS  ISE model number(s) HUS728T6TAL5200, HUS728T6TAL4200",
      "version": "RS09",
      "release_id": "8GM6M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-04-11T11:06:44Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025815M/2/SAS-Drive_Firmware_8GM6M_WN64_RS09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8GM6M",
      "size": 24607448,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SAS HDD, Model number HUS728T6TAL5200.\nFW update for WDC Vela-AP 4Kn SAS HDD, Model number HUS728T6TAL4200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "9d3a909718077b49b7c8c9902c53facf85f1cfdfc24edabfce073cd264cc800c",
      "name": "Hitachi PU09 for Vela-A ISE model number(s) HUS726T4TALS200",
      "version": "PU09",
      "release_id": "J5K8G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T11:03:41Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024400M/2/SAS-Drive_Firmware_J5K8G_WN64_PU09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J5K8G",
      "size": 24727008,
      "reboot_required": false,
      "description": "FW update for WDC Vela-A 512n SAS HDD, Model number HUS726T4TALS200.\n\n- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "6cb9b2e14559a89fe993a07e8c8367a371dc1253168afd133677270b5bcb3eec",
      "name": "Seagate ST38 for model number(s) ST600MM0069 and ST1200MM0099",
      "version": "ST38",
      "release_id": "FFN16",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T10:22:22Z",
      "released": "2024-05-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11502881M/2/SAS-Drive_Firmware_FFN16_WN64_ST38_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FFN16",
      "size": 24522520,
      "reboot_required": false,
      "description": "This release contains firmware version ST38 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes:\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "736e89923bb3c28df28dc52a33909657ef3c7f17816fa6be7cd3ade0082728b9",
      "name": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "version": "C40E",
      "release_id": "57MM2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:28:10Z",
      "released": "2024-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374876M/2/SAS-Drive_Firmware_57MM2_WN64_C40E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=57MM2",
      "size": 24391360,
      "reboot_required": false,
      "description": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "revision_history": "Fixes: \n\n- Fix1: FW is fixed to execute the flush process and Flash Memory parameter modification process exclusively.\n- Fix2: Fixed that the host I/O proceed by the skip of GC if the validity determination process of user data takes time.\n- Fix3: Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "2d586d18bf6bfd668a4b76e782765a56bb78bffe1a219c60613e9b1ae474dbde",
      "name": "Model numbers are KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8, KPM7XRUG960G, KPM7XVUG800G, KPM7XMUG400G, KPM7XMUG800G, KPM7XMUG1T60",
      "version": "C10E",
      "release_id": "T21WT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:11:55Z",
      "released": "2024-06-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374981M/2/SAS-Drive_Firmware_T21WT_WN64_C10E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T21WT",
      "size": 24314272,
      "reboot_required": false,
      "description": "This release contains firmware version C10E for Kioxia PM7 24Gbps SAS 2.5 (10WPD, 1WPD, 3WPD).\nModel numbers are KPM7XMUG400G, KPM7XMUG800G, and KPM7XMUG1T60,\nKPM7XVUG800G, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8,KPM7XRUG960G, KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3.",
      "revision_history": "Fix:\n\n-  Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "082e6bb0f73c774d9d165c7b3ad1c18bc216df29e23658b1ce337d08333a0767",
      "name": "Toshiba EG03 for model number(s) MG04SCA20ENY and MG04SCA40ENY.",
      "version": "EG03",
      "release_id": "RG9MK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:01:08Z",
      "released": "2020-08-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06462890M/4/SAS-Drive_Firmware_RG9MK_WN64_EG03_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RG9MK",
      "size": 23788464,
      "reboot_required": false,
      "description": "This release contains firmware version EG03 for Toshiba drives. Vendor model numbers MG04SCA20ENY and MG04SCA40ENY.",
      "revision_history": "initial release"
    },
    {
      "id": "0776b5d687d3fbafca1eb2f20fa128d1b4ec7423dcc2fefe3e9f3387ab95092f",
      "name": "Kioxia BA48 FW for PM6 drives for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "version": "BA48",
      "release_id": "NGPR2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T05:55:37Z",
      "released": "2022-09-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08764563M/4/SAS-Drive_Firmware_NGPR2_WN64_BA48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NGPR2",
      "size": 24171504,
      "reboot_required": false,
      "description": "Kioxia PM6 BA48 FW for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "revision_history": "Fixes:\nInitial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "ee1dd07dfa56c50a22f52b957c6eea53779375c00ea310b32677d2cc45dccbfd",
      "name": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68",
      "version": "BD48",
      "release_id": "6DH0W",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-07T09:55:22Z",
      "released": "2023-10-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10704397M/4/SAS-Drive_Firmware_6DH0W_WN64_BD48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6DH0W",
      "size": 24247952,
      "reboot_required": false,
      "description": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68.",
      "revision_history": "Fixes :\n- Initial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "b9aa8e6ec9329a8ed6c43757740d5a9727d68f2084aef6c3a616a54e28e5ca7d",
      "name": "Toshiba EI0D for MG07 model number(s) MG07SCA12TEY, MG07SCA14TEY and MG07SCA12TAY",
      "version": "EI0D",
      "release_id": "NFFHM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-06T15:14:46Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10293591M/4/SAS-Drive_Firmware_NFFHM_WN64_EI0D_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NFFHM",
      "size": 23920304,
      "reboot_required": false,
      "description": "This release contains firmware version EI0D for MG07 model number(s) MG07SCA12TEY, MG07SCA14TEY and MG07SCA12TAY.",
      "revision_history": "-Fix an issue where an unexpected power loss can cause unrecoverable read error on the following power up"
    },
    {
      "id": "5a5e3c3b8f9ad66b5a7e31fcf5b4226dd834e4fce0cca01382f0f30afa1667b9",
      "name": "Toshiba EM05 for MG09 SAS 18TB ISE model number(s) MG09SCA12TEY, MG09SCA14TEY, MG09SCA18TEY, MG09SCA16TEY",
      "version": "EM05",
      "release_id": "8829H",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-06T14:31:53Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10293717M/5/SAS-Drive_Firmware_8829H_WN64_EM05_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8829H",
      "size": 24298736,
      "reboot_required": false,
      "description": "This release contains firmware version EM04 for Toshiba MG09 SAS 18TB ISE drives Vendor model number(s) MG09SCA12TEY, MG09SCA14TEY, MG09SCA18TEY, MG09SCA16TEY",
      "revision_history": "Fixes:\n-Initial release"
    },
    {
      "id": "1a2699d84e57826d3d2d1bce8e5346834d66c2b8870ea145619ff78e3276a0f7",
      "name": "Initial release of Segate Skybolt 15ke HDD.  Model Number ST900MM0199",
      "version": "SHS1",
      "release_id": "H1W81",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-03T11:39:00Z",
      "released": "2024-10-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12162176M/2/SAS-Drive_Firmware_H1W81_WN64_SHS1_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H1W81",
      "size": 24687568,
      "reboot_required": false,
      "description": "This release contains FW revision SHS1 for model numbers ST900MM0199,",
      "revision_history": "Fix:\n\n- Initial release"
    },
    {
      "id": "03c3e975a5c39282c38c42badb0a5b49ede4578d991c1173bc237556eff17d14",
      "name": "EGS Chipset Driver_10.1.19928.8615",
      "version": "10.1.19928.8615",
      "release_id": "C2MC3",
      "category": "Chipset",
      "category_slug": "chipset",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-04-01T04:02:08Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12931691M/3/Chipset_Driver_C2MC3_WN64_10.1.19928.8615_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C2MC3",
      "size": 8979624,
      "reboot_required": true,
      "description": "EGS Chipset Drivers_10.1.19928.8615\nAdditional manual installation is required for QAT device to support WS2022 / WS2025/ signed driver",
      "revision_history": "Fixes:\n- N/A\n\nEnhancements:\n- Update version to 10.1.19928.8615\n- Add support for 24H2 for some platforms, with provisions for future support on additional platforms"
    },
    {
      "id": "83664d939c9cfb8526c53484a2553d46f8499432e5077ee7074fc0f9d30e0827",
      "name": "Firmware GA09 Update for Longspeak SATA ISE HDD.  Model numbers: ST18000NM008D-3DL133 \u0026 ST20000NM008D-3DJ133",
      "version": "GA09",
      "release_id": "R02JH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-27T09:48:50Z",
      "released": "2025-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12915495M/1/Serial-ATA_Firmware_R02JH_WN64_GA09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R02JH",
      "size": 24250208,
      "reboot_required": false,
      "description": "Firmware Update for Longspeak SATA ISE HDD.  Model numbers: ST18000NM008D-3DL133 \u0026 ST20000NM008D-3DJ133.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Servo code change to address single stage actuator resonance issue in high vibe environment\n- Various performance improvements."
    },
    {
      "id": "184134c1a1ecf8858631bf182a7044b3ff1922ae6a878fe9c4f89795a41a6902",
      "name": "Seagate GS09 Firmware Update for Longspeak SAS ISE HDD.  Model numbers: ST18000NM007D \u0026 ST20000NM004D",
      "version": "GS09",
      "release_id": "WCTTD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-27T09:41:56Z",
      "released": "2025-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12915397M/1/SAS-Drive_Firmware_WCTTD_WN64_GS09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WCTTD",
      "size": 24555296,
      "reboot_required": false,
      "description": "Firmware Update for Longspeak SAS ISE HDD.  Model numbers: ST18000NM007D \u0026 ST20000NM004D.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Servo code change to address single stage actuator resonance issue in high vibe environment\n- Various performance improvements."
    },
    {
      "id": "2189d3c19f564af9c4adadb58dd81c7b80feda3edd4af1e38e757fc10724ae62",
      "name": "HGST EU46  for model number(s) HUC156030CSS200 and HUC156060CSS200",
      "version": "EU46",
      "release_id": "R39JH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T09:18:31Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12886071M/1/SAS-Drive_Firmware_R39JH_WN64_EU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R39JH",
      "size": 24103776,
      "reboot_required": false,
      "description": "This release contains firmware version EU46 FW changes to affect HGST King Cobra F 512n SAS ISE HDD, Model numbers HUC156060CSS200 and HUC156030CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "710a41520969170b139a0ad46b68638dc89b3cc9bed271ae5f33137141cd804d",
      "name": "HGST EK46 for model number(s) HUC156060CS4204",
      "version": "EK46",
      "release_id": "M04KK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T07:22:10Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12885013M/1/SAS-Drive_Firmware_M04KK_WN64_EK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M04KK",
      "size": 24112472,
      "reboot_required": false,
      "description": "This release contains firmware version EK46 'FW changes to affect HGST King Cobra F 4Kn SAS HDD, Model number HUC156060CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "be8cba2fe69053e9785264bea3fc29c4b30fe84a8cd65e095c114f2e7bbbf350",
      "name": "HGST EJ46  for model number(s) HUC156030CSS204,and HUC156060CSS204",
      "version": "EJ46",
      "release_id": "H53FC",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T06:20:55Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12884528M/1/SAS-Drive_Firmware_H53FC_WN64_EJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H53FC",
      "size": 24103728,
      "reboot_required": false,
      "description": "This release contains firmware version EJ46 'FW changes to affect HGST King Cobra F 512n SAS HDD, Model numbers HUC156060CSS204 and HUC156030CSS204.\nIncludes FW change to turn off drive usage logging to avoid pointer error",
      "revision_history": "Fixes:\nFixes: FW change to turn off drive usage logging to avoid pointer error"
    },
    {
      "id": "c69c0d7de49ad38ad0c52ed4cc69e17677fb3881869c747bd9a110e6b4c8bb73",
      "name": "HGST FU46  for model number(s) HUC101830CSS200, HUC101812CSS200 and HUC101860CSS200",
      "version": "FU46",
      "release_id": "DH7TM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T11:00:24Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880083M/1/SAS-Drive_Firmware_DH7TM_WN64_FU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DH7TM",
      "size": 24083696,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512n SAS ISE HDD, Model numbers  HUC101830CSS200, HUC101860CSS200, and HUC101812CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "cd1d62fa296afde305b57d1c8c09a670b8c62765e8c4a61a2570f61f4ffede28",
      "name": "HGST FK46 for model number(s) HUC101818CS4204 and HUC101818CS4204",
      "version": "FK46",
      "release_id": "V917M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T10:23:21Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880005M/1/SAS-Drive_Firmware_V917M_WN64_FK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V917M",
      "size": 24091240,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512e and 4Kn SAS HDD , Model number HUC101818CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\n'FW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "2f758b11765da0fb1b02a4e543dc569c690272a2b0b6e0aa0bfc0776af21817b",
      "name": "HGST FJ46  for model number(s) HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204",
      "version": "FJ46",
      "release_id": "DYYN1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T09:12:02Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12879555M/1/SAS-Drive_Firmware_DYYN1_WN64_FJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DYYN1",
      "size": 24083632,
      "reboot_required": false,
      "description": "This release contains FW changes to affect HGST Cobra F 512n SAS HDD, Model numbers HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204 includes FW change to turn off drive usage logging to avoid pointers error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointers error."
    },
    {
      "id": "b355fdf544e9926c98f922251403039b114b84909c30586205daffdc4062a2e0",
      "name": "Windows Server 2022 Driver 2.61.74.00 for HBA11 Controllers",
      "version": "2.61.74.00",
      "release_id": "R31NP",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-18T06:28:20Z",
      "released": "2025-03-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12872713M/1/SAS-Non-RAID_Driver_R31NP_WN64_2.61.74.00_A03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R31NP",
      "size": 14612344,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver to 2.61.74.00 for HBA345 Adapter/Front, HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter/MX/MM/MMLP Controllers."
    },
    {
      "id": "90185f8e0eb9a36b0268f12c76033b8595571088acd45cdc75763cf19f7ffb4b",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.2",
      "version": "23.21.5",
      "release_id": "YWMRX",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-14T01:06:32Z",
      "released": "2025-01-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12577197M/2/Network_Driver_YWMRX_WN64_23.21.5_232.1.133.2_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YWMRX",
      "size": 13975856,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Support for new Dell server models."
    },
    {
      "id": "8805f93f162a5e9a7282553f3a2eb98d8cfd822f43e29e41219e7f999c02fac5",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.2 update.",
      "version": "23.21.13.32",
      "release_id": "G535X",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-03-14T01:03:16Z",
      "released": "2025-01-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12577171M/2/Network_Driver_G535X_WN64_23.21.13.32_232.1.133.2_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G535X",
      "size": 14210264,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver."
    },
    {
      "id": "134f9d13a2951baa0261de65e929e12f75351064111f853eed8ca1e7ba179f07",
      "name": "Firmware Update for Toshiba MG10 SAS. Model Number MG10SCA20TEY",
      "version": "EN04",
      "release_id": "0H3CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-11T14:39:14Z",
      "released": "2025-03-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12841970M/1/SAS-Drive_Firmware_0H3CX_WN64_EN04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0H3CX",
      "size": 24586112,
      "reboot_required": false,
      "description": "Firmware Update for Toshiba MG10 SAS.  Model Number MG10SCA20TEY.\nAdded command to update Adjacent Track Interference settings, and improved the drive retry processing.",
      "revision_history": "Fixes:\nAdded UART Command to change ATI (Adjacent Track Interference) Enable/Disable settings.\nFurther strengthened the retry process as a countermeasure against false hard error detection.\nAdded retry processing as a countermeasure against the false detection of hard errors.\nMultiple performance enhancements."
    },
    {
      "id": "5bdddd1d8557db43989a33ba11ce36bc1dd41874116c02b65d9bb1d605696706",
      "name": "Seagate CimarronBP SAS FIPS for LT0E FW for Model numbers: ST8000NM022B",
      "version": "LT0E",
      "release_id": "4T1MM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-06T06:42:36Z",
      "released": "2025-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12816183M/1/SAS-Drive_Firmware_4T1MM_WN64_LT0E_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4T1MM",
      "size": 24932568,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS FIPS 512e HDD.  Model number: ST8000NM022B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "9919a72526e3192f77c158c625e5ec4efa06638905b3c239de5820e669db369e",
      "name": "BOSS Console Management driver for WS2022-2025",
      "version": "1.2.0.1055",
      "release_id": "7004G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-12-18T11:18:14Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11846807M/2/SAS-RAID_Driver_7004G_WN64_1.2.0.1055_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7004G",
      "size": 12936864,
      "reboot_required": false,
      "description": "BOSS Console Management driver for WS2022-2025",
      "revision_history": "Fixes: None,\nEnhancements: Console Management Driver enablement for MS Windows 2025."
    },
    {
      "id": "c5d54c034608aea2b30ae772d2f1f626db4814ccac68e55449f6043dcf90ab77",
      "name": "HGST RT09 for Vela-AP SATA ISE model number(s) HUS728T8TALE6L0",
      "version": "RT09",
      "release_id": "T0RX4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T09:40:40Z",
      "released": "2024-04-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025871M/1/Serial-ATA_Firmware_T0RX4_WN64_RT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T0RX4",
      "size": 13355792,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SATA HDD, Model number HUS728T8TALE6L0.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "5dfbeeafb4ce29aa30f615ae567aeed3c55b796b2de7aba6cc45b2f12cceca39",
      "name": "Hitachi PT09 for Vela-A ISE model number(s) HUS726T4TALA6L0",
      "version": "PT09",
      "release_id": "CWPJH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T09:13:23Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025719M/1/Serial-ATA_Firmware_CWPJH_WN64_PT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CWPJH",
      "size": 13487376,
      "reboot_required": false,
      "description": "'FW update for WDC Vela-A 512e SATA HDD, Model number HUS726T6TALE6L0.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "3da2d1c93d40ba01200cdc48b85bb0f0a85dcb6e489b9eaa0d9d32bcbf861b9f",
      "name": "HGST PS09 for Vela-A ISE model number(s) HUS726T6TAL4200 and HUS726T6TAL5200",
      "version": "PS09",
      "release_id": "8MJFT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T07:20:39Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024641M/1/SAS-Drive_Firmware_8MJFT_WN64_PS09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8MJFT",
      "size": 13464192,
      "reboot_required": false,
      "description": "This release contains firmware version PS09 for HGST Vela-A ISE drives - Vendor model number(s) HUS726T6TAL4200 and HUS726T6TAL5200.\n'FW update for WDC Vela-A 512e SAS HDD, Model number HUS726T6TAL5200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "065fa4836a3f37c80b73880763125794567bd147de5257395c832ecef2926d1c",
      "name": "HGST NT11 for model number  HGST HUH721212ALE600.",
      "version": "NT11",
      "release_id": "JCYF6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-08-22T16:02:52Z",
      "released": "2024-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12015624M/1/Serial-ATA_Firmware_JCYF6_WN64_NT11_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JCYF6",
      "size": 13351208,
      "reboot_required": false,
      "description": "This release contains firmware version NT11 for HGST drives. Vendor model number HUH721212ALE600.\nFW update for WDC Leo-A 512e SATA HDD, Model number HUH721212ALE600.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance."
    },
    {
      "id": "632cefa984ce903c90ae86afbe7b607b60915f5c751fe564c63e5b134b5be866",
      "name": "HGST NM11 for model number(s) HUH721212AL5205",
      "version": "NM11",
      "release_id": "M6T4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-08-22T15:02:58Z",
      "released": "2024-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12015224M/1/SAS-Drive_Firmware_M6T4D_WN64_NM11_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M6T4D",
      "size": 13326064,
      "reboot_required": false,
      "description": "This release contains firmware version NM11 for HGST drives. Vendor model numbers HUH721212AL5205 of capacity 12TB.\n\"FW update for WDC Leo-A 512e SAS FIPS HDD, Model number HUH721212AL5205.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.\"",
      "revision_history": "\"-Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance\""
    },
    {
      "id": "2e142fa2b3bba65e6701761803eb6b88963468bee9960a715304452f1a20de58",
      "name": "Intel NIC Family Version 23.0.0 Firmware for Intel I350 and X550 Adapters",
      "version": "23.0.8",
      "release_id": "WVM0R",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-08T02:04:05Z",
      "released": "2024-07-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890380M/3/Network_Firmware_WVM0R_WN64_23.0.8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WVM0R",
      "size": 13964792,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 23.0.X on Intel I350, I354 and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "Fixes\n=====\n   - Fixed problem where updating I350 NICs would not preserve the Virtualization Mode and would reset \n     the Virtualization Mode to the factory default of \"None\". {266366}\n   - Fixed an issue where Intel i350-based NICs would display invalid boot options in Boot Manager in the \n     legacy boot mode. {277961}\n     \nKnown Issues\n============\n   - Devices based on the Intel(R) Ethernet I350 controller do not support the LLDP Discovery feature\n     with Dell iDRAC.\n   - Received packets with incorrect length can generate alarms in VMware ESXi 7.0U2 and later.\n     These alarms can be ignored. Please reference this VMware KB article for more details: \n     https://kb.vmware.com/s/article/83627. {229496, 232005}"
    },
    {
      "id": "a3327e1940b3fe3b81e47fa9d3bb7aeffd6956b5f4ee06f4a9f14c97f3c83a19",
      "name": "Samsung PM1653 drives for DSG9 FW for model numbers MZILG960HCHQAD3, MZILG1T9HCJRAD3, MZILG3T8HCLSAD3, MZILG7T6HBLAAD3 and MZILG15THBLAAD3",
      "version": "DSG9",
      "release_id": "3MV58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T17:20:50Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11939710M/1/SAS-Drive_Firmware_3MV58_WN64_DSG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3MV58",
      "size": 13264392,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count acuracy and drive temperature reporting during format operations. Firmware version DSG9 for Samsung PM1653 drives. Vendor model numbers MZILG960HCHQ-0AD3, MZILG1T9HCJR-0AD3, MZILG3T8HCLS-0AD3, MZILG7T6HBLA-0AD3, and MZILG15THBLA-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "e15c231399536e80009d372366b4e72a4c66dedf951ad1fa78d1309ab3e37961",
      "name": "Samsung PM1655 drives for FW DWG9 for model numbers MZILG800HCHQAD3, MZILG1T6HCJRAD3 and MZILG3T2HCLSAD3",
      "version": "DWG9",
      "release_id": "7MTXM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T08:00:58Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11937657M/1/SAS-Drive_Firmware_7MTXM_WN64_DWG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7MTXM",
      "size": 13261200,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count accuracy and drive temperature reporting during format operations. Firmware version DWG9 for Samsung PM1655 drives. Vendor model numbers MZILG800HCHQ-0AD3, MZILG1T6HCJR-0AD3, and MZILG3T2HCLS-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "0526a6575fe93e790f6279cc0dd58458ab6a1bb5e0c174894d6a1c9d408a9929",
      "name": "Intel Lewisburg C62x Series Chipset Driver",
      "version": "10.1.19913.8607",
      "release_id": "H0WTV",
      "category": "Chipset",
      "category_slug": "chipset",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2024-07-30T06:43:05Z",
      "released": "2024-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11880748M/2/Chipset_Driver_H0WTV_WN64_10.1.19913.8607_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H0WTV",
      "size": 8972328,
      "reboot_required": true,
      "description": "This package provides the Chipset driver for the Intel Lewisburg C62x Series Chipset and is supported on 15G PowerEdge systems running Microsoft Windows Server 2016 x64, Windows Server 2019, Window Server 2022 and HCI Azure., Intel Tatlow Platform C25x supported.",
      "revision_history": "Fixes:\n- N/A\n\nEnhancements :\n- Enabling WS2025 OS support"
    },
    {
      "id": "6dffa0fa05d98ecf5dd6f683737e3ab3d4e113f263fe4ec62004af5ecf3268e8",
      "name": "Intel NIC Family Version 23.0.0 Drivers for Windows 64-bit Operating Systems",
      "version": "23.0.0",
      "release_id": "6JHVK",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-07-19T15:27:45Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11890492M/1/Network_Driver_6JHVK_WN64_23.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6JHVK",
      "size": 42776640,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "See readme.txt for more info."
    },
    {
      "id": "2d691ed72b31c474544f0a9a0818d69f0e4ab820992ea73115f41143fafef850",
      "name": "WD BCQ firmware G138  for model numbers WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200,WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200,WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200",
      "version": "G138",
      "release_id": "8W5WF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T07:34:09Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11655805M/1/SAS-Drive_Firmware_8W5WF_WN64_G138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8W5WF",
      "size": 12585960,
      "reboot_required": false,
      "description": "This release contains firmware version G138 for WD BCQ drives. Vendor model numbers WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200, WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200, WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries."
    },
    {
      "id": "13796d98c89ff1cc8cda76d598f7dfe5ccc925a8fadfd3999fb71e9fbcb079fb",
      "name": "WDC Bear Cove Quantum FIPS-140 L138 for 1WPD and 3WPD  model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205,WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "version": "L138",
      "release_id": "16C85",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T05:58:21Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11654668M/1/SAS-Drive_Firmware_16C85_WN64_L138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=16C85",
      "size": 12580296,
      "reboot_required": false,
      "description": "This release contains firmware version L138 for WDC Bear Cove Quantum FIPS-140 1WPD and 3WPD. For model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205, WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "457ece2bc644069fab86e59d8d629ce72abd2ea321c4374bec6ae5340321f69f",
      "name": "Samsung PM9A3 NVMe M.2 22x110 for FW 1.1.1 version for model numbers(s) MZ1L2960HCJR-00AD3, MZ1L21T9HCLS-00AD3.",
      "version": "1.1.1",
      "release_id": "HX5W6",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-20T10:56:05Z",
      "released": "2024-05-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11638925M/1/Express-Flash-PCIe-SSD_Firmware_HX5W6_WN64_1.1.1_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HX5W6",
      "size": 9471384,
      "reboot_required": false,
      "description": "Samsung PM9A3 NVMe M.2 22x110 for FW 1.1.1 version for model numbers(s) MZ1L2960HCJR-00AD3, MZ1L21T9HCLS-00AD3. \n\nThis update includes important reliability enhancements and also improves drive enumeration. Firmware version 1.1.1 for Samsung PM9A3 M.2 drives, models MZ1L21T9HCLS-00AD3 and MZ1L2960HCJR-00AD3.",
      "revision_history": "Disable (LTR( Latency Tolerance Reporting) to avoid delays on non-supported systems\n- Additional command syntax updates.\n- Add Log page C0 support"
    },
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "ec7b4413408504ee11e7cc02edb1960d318d54ce4c0cfc3635ef7ba19403b254",
      "name": "SK HYNIX DE08 for model numbers HFS960G32FEH-7A10A, HFS1T9G32FEH-7A10A, HFS3T8G32FEH-7410A and HFS480G32FEH-7410A",
      "version": "DE08",
      "release_id": "3DTV4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T03:52:03Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11629605M/1/Serial-ATA_Firmware_3DTV4_WN64_DE08_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3DTV4",
      "size": 13594832,
      "reboot_required": false,
      "description": "This release contains firmware version DE08 for SK HYNIX model numbers HFS960G32FEH-7A10A, HFS1T9G32FEH-7A10A, HFS3T8G32FEH-7410A and HFS480G32FEH-7410A.",
      "revision_history": "Fix: \n\n- Improvements made to Background Scanning functionality"
    },
    {
      "id": "333f510745d6bedcbadf00dfa27e5b7532c32ae94fea09bd9ec4a93617b1329f",
      "name": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s)  KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960",
      "version": "CA0C",
      "release_id": "1YD58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T15:53:43Z",
      "released": "2023-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10810459M/2/SAS-Drive_Firmware_1YD58_WN64_CA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1YD58",
      "size": 12708760,
      "reboot_required": false,
      "description": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s) KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960G.",
      "revision_history": "Fixes: \nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed in a different area, the drive may encounter the below failure mode. Once a drive falls into this failure mode, it cannot be recovered by power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. Data buffer is used for data transfer during Wear-Leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow.                                                                                                             Write Cache Issue: An issue that may cause firmware downloads to fail in the event of a capacitor failure. This failure is triggered by firmware download in the Write Cache Off state, and even if it occurs, it does not lead to drive failure and can be recovered by a reset or Power cycle.\nCause: When FW Update is executed in the Write Cache Off state and then restarted, capacitor discharge control is activated. In this case, unintended PLP occurs because capacitor discharge was controlled in the order of capacitor discharge and then PLP interrupt mask.\nFix: When capacitor discharge control is executed after FW Update in the Write Cache Off state and the system is restarted, the PLP interrupt mask is changed to control in the order of PLP interrupt mask and then capacitor discharge."
    },
    {
      "id": "a1178484b04285ac191ec9219242d56e944c47e79f02b74de40e05534be8c7b3",
      "name": "Seagate SBW6 for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "version": "SBW6",
      "release_id": "5G3PW",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T06:30:37Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11496475M/1/SAS-Drive_Firmware_5G3PW_WN64_SBW6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5G3PW",
      "size": 13261504,
      "reboot_required": false,
      "description": "This release contains firmware version SBW6 Seagate for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "revision_history": "Fixes:\n\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "aea4393efcfda0f36a0eec8381be0d3c12daa8f85bf21fc7aca2b27303b786f8",
      "name": "Seagate Summit HDD ISE SAS SWS5 FW for model number ST12000NM007H.",
      "version": "SWS5",
      "release_id": "KVGNJ",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-04-12T09:48:59Z",
      "released": "2024-04-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11491581M/1/SAS-Drive_Firmware_KVGNJ_WN64_SWS5_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KVGNJ",
      "size": 15443480,
      "reboot_required": false,
      "description": "The initial release of Seagate Summit SAS 12TB ISE for model number ST12000NM007H.",
      "revision_history": "Fixes:\n\n- Firmware modification to reduce current required for drive spin-up.\n- Fixes for potential assert, command timeout, and drive not ready issues."
    },
    {
      "id": "7519e5a247e4faef23fec143f6cfdc2642adede2aacdf68e0927d6ac7366dd4b",
      "name": "Seagate Summit HDD ISE SYA3 FW for model numbers ST12000NM002H, ST16000NM002H, ST20000NM002H.",
      "version": "SYA3",
      "release_id": "41W0M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-04-11T18:30:54Z",
      "released": "2024-04-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11487520M/1/Serial-ATA_Firmware_41W0M_WN64_SYA3_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=41W0M",
      "size": 15446712,
      "reboot_required": false,
      "description": "The initial release of Seagate Summit SATA 12TB/16TB/20TB ISE for Model numbers ST12000NM002H, ST16000NM002H, ST20000NM002H.",
      "revision_history": "Fixes:\n\n- Firmware modification to reduce current required for drive spin-up.\n- Fixes for potential assert, command timeout, and drive not ready issues.\n- Modification to address potential SATA Santitize issue."
    },
    {
      "id": "744dcccc63193f44275c6cdb20efc6b471b00f156a4be43ab2e14a3586ea99a6",
      "name": "Windows Server 2022 64bit driver for PERC S150 Controller",
      "version": "6.7.0.0003",
      "release_id": "26KG9",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2024-03-26T16:03:30Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422737M/1/SAS-RAID_Driver_26KG9_WN64_6.7.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=26KG9",
      "size": 6625096,
      "reboot_required": true,
      "description": "Windows Server 2022 64bit driver for PERC S150 Controller"
    },
    {
      "id": "8b123fe887879d8ad789dc986b35da9f2ec22affe26654a6bb6e8b20640f3cc6",
      "name": "Windows Server 2019 64bit driver for PERC S150 Controller",
      "version": "6.7.0.0003",
      "release_id": "XVCP2",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T16:00:59Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422723M/1/SAS-RAID_Driver_XVCP2_WN64_6.7.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XVCP2",
      "size": 6625104,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S150 Controller"
    },
    {
      "id": "4606e48b823ee2191814a270d0bce99199bdd8593b77bfa502e96ec5af12b803",
      "name": "Toshiba GF07 for MG09 SATA 18TB ISE model number(s) MG09ACA12TEY,MG09ACA14TEY,MG09ACA16TEY,MG09ACA18TEY",
      "version": "GF07",
      "release_id": "8R5VG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-08T08:07:55Z",
      "released": "2024-02-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11218588M/3/Serial-ATA_Firmware_8R5VG_WN64_GF07_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8R5VG",
      "size": 12994112,
      "reboot_required": false,
      "description": "This release contains firmware version GF06 for Toshiba MG09 SATA 18TB ISE drives - Vendor model number(s) MG09ACA12TEY,MG09ACA14TEY,MG09ACA16TEY,MG09ACA18TEY",
      "revision_history": "Fixes:\n-Initial release"
    },
    {
      "id": "d86b90f28fe1d8aad0a35501f97aec38c1b7821eff4a67a08d7ebce6a14c831b",
      "name": "Samsung SM883 MU SSDR, FW  HF58. Vendor model numbers MZ7KH480HAHQ0D3, MZ7KH960HAJR0D3, MZ7KH1T9HAJR0D3, and MZ7KH3T8HALS0D3.",
      "version": "HF58",
      "release_id": "3J3JR",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-28T11:17:02Z",
      "released": "2021-04-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06950272M/3/Serial-ATA_Firmware_3J3JR_WN64_HF58_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3J3JR",
      "size": 13590256,
      "reboot_required": false,
      "description": "This release contains firmware version HF58 for vendor model numbers MZ7KH480HAHQ0D3, MZ7KH960HAJR0D3, MZ7KH1T9HAJR0D3, and MZ7KH3T8HALS0D3",
      "revision_history": "Fixes:-\n- Correct Log Addres 99h Vendor Name string from \"DELL\" to \"SAMSUNG\".\n- Disable RESTRICTED SANITIZE OVERRIDES SECURITY feature, per Dell spec.\n- Fix Pin 11 OOB Default Signal issue, where signal is returned \"High\" after repeated FW updates.\n- Other minor fixes as described in the FCN."
    },
    {
      "id": "fda7ed85944e9d8962289de66a326eff2cd94be829b58a3bdef99383702c6311",
      "name": "Toshiba EE0A for model number(s) AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "version": "EE0A",
      "release_id": "50N1P",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-13T11:38:43Z",
      "released": "2022-04-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08344514M/2/SAS-Drive_Firmware_50N1P_WN64_EE0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=50N1P",
      "size": 12543400,
      "reboot_required": false,
      "description": "This release contains firmware version EE0A for Toshiba drives. Vendor model numbers AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "revision_history": "Fixes:\n- Improvements that reduce the risk of media errors"
    },
    {
      "id": "8b7171c9e267a84502b4dd3b631bc09cc0e0ab25b12cc110d8273af3b0f84615",
      "name": "Seagate 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "version": "4S0C",
      "release_id": "G04C8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-12T12:12:27Z",
      "released": "2022-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08459420M/2/SAS-Drive_Firmware_G04C8_WN64_4S0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G04C8",
      "size": 12625072,
      "reboot_required": false,
      "description": "This release contains Seagate firmware version 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "revision_history": "Fixes:\n-Fix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\n-Fix an issue that can return corrupt data after a power cycle in a corner case.\n-Fix an issue that can return the sense code 09/80/00 to a WRITE command.\n-Fix issues that can cause command timeout.\n-Fix issues that can cause drive assert.\n-Fix issues that can cause drive hang condition.\n\nEnhancements:\n-Improve protocol spec compliance.\n-Improve throughput performance for specific workloads.\n-Improve error logging/sense data reporting.\n-\nFix an issue that can cause drive-not-ready."
    },
    {
      "id": "f48d1e0bb30064c3585d6c60901c49a56223945efbe756f582e821086eb712ac",
      "name": "This release contains firmware version CSFD for STX model numbers ST8000NM010A. Capacity of 8TB.",
      "version": "CSFD",
      "release_id": "6Y6YT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-12T11:56:00Z",
      "released": "2023-09-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10148510M/2/SAS-Drive_Firmware_6Y6YT_WN64_CSFD_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6Y6YT",
      "size": 13240760,
      "reboot_required": false,
      "description": "This release contains firmware version CSFD for STX model numbers ST8000NM010A. Capacity of 8TB.",
      "revision_history": "Fixes:\nFix an issue where HARD_RESET primitive sequence can be missed.\nFix an issue where stale data can be returned.\nFix an issue that can cause erroneous SMART trips.\nFix an issue that can cause format corrupt.\nFix issues to ensure background scans are performed as scheduled.\nFix an issue that can cause hardware error being reported erroneously.\nFix an issue where Persistent Reservation does not persist on FW download.\nFix an issue that can cause Aborted Command error after a power cycle.\nFix an issue that can cause the drive's not being detected by the host after hot plug.\nFix an issue that can cause IOEDC error then assert.\nFix an issue that can cause IOEDC error.\nFix issues that can cause command timeout.\nFix issues that can cause assert.\nFix issues that can cause drive hang condition.\nEnhancements:\nImprove error logging / reporting accuracy.\nImprove performance for certain workloads.\nImprove SAS protocol compliance."
    },
    {
      "id": "9480b0b971826e03175ff73b2165060a7b6c51db66c444dba1aff76f43dd509d",
      "name": "Dell HBA350i Adapter/MM/MMLP Controllers firmware version 24.15.10.00",
      "version": "24.15.10.00",
      "release_id": "VXP77",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-12T09:55:40Z",
      "released": "2023-03-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09659598M/3/SAS-Non-RAID_Firmware_VXP77_WN64_24.15.10.00_A04_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VXP77",
      "size": 11630744,
      "reboot_required": true,
      "description": "Dell HBA350i Adapter/MM/MMLP Controllers firmware version 24.15.10.00",
      "revision_history": "Fixes:\n-Fixed an issue related to functional level reset when the HBA device was used as passthrough in VM.\n-Fixed an issue related to the HBA initialization when the system boot mode is switching between UEFI/BIOS \u0026 BIOS/UEFI.\n\nEnhancements:\n-None"
    },
    {
      "id": "8da0d8a73db69e905da9ab84e0d8369f57269a8fbb2af8c2667c6009ea539137",
      "name": "Dell HBA345 Front/Adapter firmware version 24.15.10.00",
      "version": "24.15.10.00",
      "release_id": "FV16K",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-12T09:35:16Z",
      "released": "2023-03-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09659562M/2/SAS-Non-RAID_Firmware_FV16K_WN64_24.15.10.00_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FV16K",
      "size": 10098224,
      "reboot_required": true,
      "description": "Dell HBA345 Front/Adapter firmware version 24.15.10.00",
      "revision_history": "Fixes:\n-Fixed an issue related to functional level reset when the HBA device was used as passthrough in VM.\n-Fixed an issue related to the HBA initialization when the system boot mode is switching between UEFI/BIOS \u0026 BIOS/UEFI.\n\nEnhancements:\nN/A"
    },
    {
      "id": "8f7c4b18c6825883793e434928b852626ddf0c47889eed466d48ce34ec991ce6",
      "name": "PERC H345 Controller Firmware version 51.16.0-4076",
      "version": "51.16.0-4076",
      "release_id": "5HV0H",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-06T22:33:45Z",
      "released": "2021-07-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07551614M/2/SAS-RAID_Firmware_5HV0H_WN64_51.16.0-4076_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5HV0H",
      "size": 14634288,
      "reboot_required": false,
      "description": "PERC H345 Controller Firmware version: 51.16.0-4076",
      "revision_history": "Fixes:\n\n    -Fixed issue where controller would fault on boot in systems with multiple backplanes.\n    -Fixed issue where Medium Errors found on drives were not reported during rebuilds and copybacks.\n    -Fixed issue where controller would fault during a firmware downgrade.\n    -Fixed issue where Bad PHY events were incorrectly reported.\n    -Fixed issue where SATA Drives where controller would take too long to timeout a link recovery on an unresponsive drive."
    },
    {
      "id": "adcdd14657ff15c5609da1a3bb478ca3f37b2bf3a1c019cba77db446f7b8f00b",
      "name": "Toshiba DBC4 for model number(s) KHK6YRM8240G, KHK6YRM8480G, KHK6YRSE480G, KHK6YRSE960G, KHK6YRSE1T92, KHK6YRSE3T84, KHK6YRSE7T68, KHK6YVSE480G, KHK6YVSE960G, KHK6YVSE1T92, KHK6YVSE3T84.",
      "version": "DBC4",
      "release_id": "W0YR1",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-02T06:44:59Z",
      "released": "2020-06-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06255401M/3/Serial-ATA_Firmware_W0YR1_WN64_DBC4_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=W0YR1",
      "size": 12622472,
      "reboot_required": false,
      "description": "This release contains firmware version DBC4 for Toshiba drives. Vendor model numbers KHK6YRM8240G, KHK6YRM8480G, KHK6YRSE480G, KHK6YRSE960G, KHK6YRSE1T92, KHK6YRSE3T84, KHK6YRSE7T68, KHK6YVSE480G, KHK6YVSE960G, KHK6YVSE1T92, KHK6YVSE3T84.",
      "revision_history": "Fixes:\n- Fixed error found during Write Uncorrectable testing that reported 07/27/00 instead of 03/11/00.\nEnhancements:\n- Added Pin 11 OOB Temperature reporting capability per ENG0015386 A04.\n- Performance improvements on Random Read and Write."
    },
    {
      "id": "480d4e9ce14a83d2047d570eaf2ae2092e247347f514a1ca3e9da63fa1704440",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 22.7 update.",
      "version": "22.71.11.10",
      "release_id": "1TT78",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2024-01-31T23:20:53Z",
      "released": "2023-09-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10551555M/2/Network_Driver_1TT78_WN64_22.71.11.10_227.1.111.0_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1TT78",
      "size": 5933280,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.",
      "revision_history": "Fixes:\n- None.\n\nEnhancements:\n- Support for additional PowerEdge server models."
    },
    {
      "id": "011cdb21bdfbaa51a2cf874a7f8ca3a3e056524999b2d1a596b114d27e7ea2fc",
      "name": "Seagate CAJD for model numbers ST1000NM004A-2MN130, ST2000NM012A-2MP130, ST4000NM016A-2HZ130",
      "version": "CAJD",
      "release_id": "RWK48",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-31T07:56:25Z",
      "released": "2024-01-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11201542M/1/Serial-ATA_Firmware_RWK48_WN64_CAJD_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RWK48",
      "size": 12823344,
      "reboot_required": false,
      "description": "This release contains firmware version CAJD for STX model numbers ST1000NM004A-2MN130, ST2000NM012A-2MP130, ST4000NM016A-2HZ130. Capacity of 1TB,2TB, and 4TB",
      "revision_history": "Fixes: \n- Fix for high load/unload count with host read device statistics log upon wake up from Idle2.\n- Fix for potential write uncorrectable error in Write Log Page for Non-Volatile Cache."
    },
    {
      "id": "c0c35ec567586d3e598e838a175f119121b72445109dbe8bf5b5795acfdf074a",
      "name": "Intel DL6R  for model number(s) SSDSCKKB240G8R, SSDSCKKB480G8R, SSDSCKKB960G8R.",
      "version": "DL6R",
      "release_id": "Y1P10",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T09:29:44Z",
      "released": "2020-09-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06303847M/2/Serial-ATA_Firmware_Y1P10_WN64_DL6R_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=Y1P10",
      "size": 12056704,
      "reboot_required": false,
      "description": "This release contains firmware version DL6R for Intel drives. Vendor model numbers  SSDSCKKB240G8R, SSDSCKKB480G8R, SSDSCKKB960G8R.",
      "revision_history": "Fixes:\n-SMART attribute shift solution\n-MRR settings to mitigate BJ004 issue\n-Fixes an issue where drive stops responding after soft-reboot following windows install\n\nEnhancements:\nN/A"
    },
    {
      "id": "091b0ab88757d384d3581779de182e71e297e611dafaf2c80022ea2d2ddcc314",
      "name": "Toshiba FK5D for model number(s) TOSHIBA MG04ACA100NY, TOSHIBA  MG04ACA200NY and TOSHIBA MG04ACA400NY.",
      "version": "FK5D",
      "release_id": "6D4CG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T09:05:59Z",
      "released": "2022-10-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11195642M/1/Serial-ATA_Firmware_6D4CG_WN64_FK5D_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6D4CG",
      "size": 12566424,
      "reboot_required": false,
      "description": "This release contains firmware version FK5D for Toshiba drives. Vendor model numbers TOSHIBA MG04ACA100NY, TOSHIBA MG04ACA200NY and TOSHIBA  MG04ACA400NY.",
      "revision_history": "Fixes:\nSeek algorithm adjusted to reduces spikes in acoustic levels leading to audible noise concerns.\nDEFT algorithm modified to ensure drives with modified seek algorithm will still pass DEFT testing."
    },
    {
      "id": "eeb214c6eeee69a5f0df9a8a636c9e2cb91affb59cdc9a3d676d62028dad541d",
      "name": "Micron K803 for 5400 SATA model number(s) MTFDDAK7T6TGA",
      "version": "K803",
      "release_id": "333Y2",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-30T06:44:45Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606516M/2/Serial-ATA_Firmware_333Y2_WN64_K803_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=333Y2",
      "size": 12359152,
      "reboot_required": false,
      "description": "This release contains firmware version K803 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK7T6TGA",
      "revision_history": "Fixes:\n- Fixes to address performance."
    },
    {
      "id": "6c992026ccb1034e5d76c43933dc44c2595da3c48f49b380535843c14de95847",
      "name": "Micron K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "version": "K003",
      "release_id": "RJ0WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T14:41:30Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606437M/2/Serial-ATA_Firmware_RJ0WY_WN64_K003_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJ0WY",
      "size": 12627936,
      "reboot_required": false,
      "description": "This release contains firmware version K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "revision_history": "Fixes:\n\n-Fixes to address performance."
    },
    {
      "id": "7f5691c4430c7327b0a80ce3ef83995daadc50336c7a6a3a67edf9b560b1db34",
      "name": "Micron K403 for 5400 SATA model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB",
      "version": "K403",
      "release_id": "JTW3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T06:58:14Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606566M/2/Serial-ATA_Firmware_JTW3W_WN64_K403_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTW3W",
      "size": 12364032,
      "reboot_required": false,
      "description": "This release contains firmware version K403 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB.",
      "revision_history": "Fixes:\n\n- Fixes to address performance."
    },
    {
      "id": "bb57e28a339c3b858c5bc6141c05945f383f59350eff916b1033dc704177bd35",
      "name": "Seagate PB53 for model number(s) ST8000NM0205..",
      "version": "PB53",
      "release_id": "MR6RH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-24T08:13:34Z",
      "released": "2017-02-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04155724M/2/Serial-ATA_Firmware_MR6RH_WN64_PB53_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MR6RH",
      "size": 12786248,
      "reboot_required": false,
      "description": "This release contains firmware version PB53 for Seagate drives. Vendor model numbers ST8000NM0205..",
      "revision_history": "Initial release"
    },
    {
      "id": "7d98bb95a79ce046742b0e7a9a29f34daca02fb5fe008896efcc9775bdddcafc",
      "name": "HGST KV45  for model number(s) HGST HUS726020ALA610 and HGST HUS726040ALA610.",
      "version": "KV45",
      "release_id": "X59KC",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-23T17:40:36Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150839M/2/Serial-ATA_Firmware_X59KC_WN64_KV45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X59KC",
      "size": 12403400,
      "reboot_required": false,
      "description": "This release contains the firmware revision HGST KV45  for Aries K Plus drive model number(s) HGST HUS726020ALA610 and HGST HUS726040ALA610.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "61edd309f7f5b8a0379422e8f130a8a435c50d219bf19779761e531913b587b5",
      "name": "Seagate DB34 for model number(s) ST4000NM0265-2DC107, ST2000NM0145-2DC104 and ST1000NM0095-2DC10C.",
      "version": "DB34",
      "release_id": "M5GJ1",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T16:20:40Z",
      "released": "2017-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04310774M/2/Serial-ATA_Firmware_M5GJ1_WN64_DB34_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M5GJ1",
      "size": 11438848,
      "reboot_required": false,
      "description": "This release contains firmware version DB34 for Seagate drives. Vendor model numbers ST4000NM0265-2DC107, ST2000NM0145-2DC104 and ST1000NM0095-2DC10C.",
      "revision_history": "Fixes:\n-Fix an issue where timeout can result by serial port noise\n-Fix issues where assert condition can result\n-Fix an issue where IOEDC error can result\n-Fix an issue where hang event can result\n-Fix issues related to DST funcitonality\n\nEnhancements:\n-Improve status reporting/logging accuracy"
    },
    {
      "id": "d0c7958e2db41a378a45dea89a33b1da584e47097bf4dc0ae52d469ebd6efa7d",
      "name": "Micron SED J408 firmware for model number(s) MTFDDAK3T8TDS and MTFDDAK3T8TDT",
      "version": "J408",
      "release_id": "VX44T",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T13:37:47Z",
      "released": "2023-09-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10427733M/2/Serial-ATA_Firmware_VX44T_WN64_J408_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VX44T",
      "size": 12304552,
      "reboot_required": false,
      "description": "This release contains firmware version J408 for Micron SED family of drives (3.84TB capacity). Drive model numbers MTFDDAK3T8TDS and MTFDDAK3T8TDT.",
      "revision_history": "Fixes:\n\n- Fixes for FW assert issue and power loss handeling issue."
    },
    {
      "id": "af718bba045a1770880a3798635bd2970568b875f053f212b6a59895db94ec42",
      "name": "HGST MU03 for model number(s) HUS722T2TALA600 and HUS722T1TALA600.",
      "version": "MU03",
      "release_id": "V3DJM",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:51:43Z",
      "released": "2018-08-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05040482M/6/Serial-ATA_Firmware_V3DJM_WN64_MU03_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V3DJM",
      "size": 12145288,
      "reboot_required": false,
      "description": "This release contains firmware version MU03 for HGST drives. Vendor model numbers HUS722T2TALA600 and HUS722T1TALA600.",
      "revision_history": "Fixes\n- Fix for an possible interrupt during Dell factory process during repeated I/O commands.\n\nEnhancements\nn/a"
    },
    {
      "id": "43da4fa3e46839dfa4494884323fbe63d1a7b0b55e614d1248d5f5fb5c3a1640",
      "name": "Micron J408 for the model number(s)MTFDDAK3T8TDS and MTFDDAK3T8TDT .",
      "version": "J408",
      "release_id": "R9YDC",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:49:13Z",
      "released": "2023-09-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10270252M/2/Serial-ATA_Firmware_R9YDC_WN64_J408_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R9YDC",
      "size": 11675960,
      "reboot_required": false,
      "description": "This release contains firmware version J408 for Micron drives. Vendor model numbers MTFDDAK3T8TDS and MTFDDAK3T8TDT.",
      "revision_history": "Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "e476ba88da356bad67538ce06e54a64af28ea4c555ed2c8163226e0f77f448f0",
      "name": "Micron J008 SED firmware for model numbers MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS, MTFDDAK480TDT, MTFDDAK960TDT, and MTFDDAK1T9TDT.",
      "version": "J008",
      "release_id": "CX0H8",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:48:55Z",
      "released": "2023-09-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10433741M/2/Serial-ATA_Firmware_CX0H8_WN64_J008_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CX0H8",
      "size": 11680080,
      "reboot_required": false,
      "description": "This release contains firmware version J008 for Micron SED RI  and MU family of drives (capacities of 1.92TB and lower). Drive model numbers MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS, MTFDDAK480TDT, MTFDDAK960TDT, and MTFDDAK1T9TDT.",
      "revision_history": "Fixes:\n-Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "fac9a96d3131d0683ff088b6b7c569bcedb7ed1b44313e780ea02cedbb46fd62",
      "name": "Seagate EA04 for model number(s) ST2000NM0018-2F3130 and ST1000NM0018-2F2130.",
      "version": "EA04",
      "release_id": "CMK5N",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:45:56Z",
      "released": "2017-05-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04268619M/2/Serial-ATA_Firmware_CMK5N_WN64_EA04_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CMK5N",
      "size": 10708496,
      "reboot_required": false,
      "description": "This release contains firmware version EA04 for Seagate drives. Vendor model numbers ST2000NM0018-2F3130 and ST1000NM0018-2F2130.",
      "revision_history": "Initial Release"
    },
    {
      "id": "76b7116270b3cd4c1c9c86222e1f499696f02117527805b4d018abad824073c8",
      "name": "Intel Youngsville refresh DL6B for model number(s). SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R",
      "version": "DL6B",
      "release_id": "4DW70",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:45:55Z",
      "released": "2023-12-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10541168M/2/Serial-ATA_Firmware_4DW70_WN64_DL6B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4DW70",
      "size": 11740528,
      "reboot_required": false,
      "description": "This release contains firmware version DL6B for Intel drives. Vendor model numbers  SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R.",
      "revision_history": "Fixes:\n\n-  Fix for SMART attribute failure observed at power up.\n-  Fix for IO timeouts resulting in device failures."
    },
    {
      "id": "709305117382547c43aded1589e324f82adb764c7933b134b3aefb415d98982a",
      "name": "Western Digital WT03 for London-D SATA ISE model number(s) WUH722222ALE600",
      "version": "WT03",
      "release_id": "HKVXJ",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:43:41Z",
      "released": "2023-07-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10267591M/2/Serial-ATA_Firmware_HKVXJ_WN64_WT03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HKVXJ",
      "size": 16088384,
      "reboot_required": false,
      "description": "This release contains firmware version WT03 for Western Digital London-D SATA drives - Vendor model number(s) WUH722222ALE600",
      "revision_history": "Fixes:\n- Reduce non-customer area update frequency during Dell Enhanced Factory Test.\n- Fix LED behavior when drive is executing the SCT WRITE SAME command."
    },
    {
      "id": "96f55e9739c37fea19403b57939d319f66a4229284d50e68ac3c3bbc9c448ccd",
      "name": "Seagate CALF FW for model numbers ST8000NM012A",
      "version": "CALF",
      "release_id": "TF6TF",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:43:18Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10296666M/2/Serial-ATA_Firmware_TF6TF_WN64_CALF_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TF6TF",
      "size": 12567824,
      "reboot_required": false,
      "description": "This release contains firmware version CALF for STX drives. Vendor model numbers ST8000NM012A.",
      "revision_history": "Fixes:\nAllow executing SetSectorConfig command even in format corrupt condition.\n-Fix an issue that can cause format operation failure.\n-Fix an issue that can cause activity LED to stop functioning after FW download.\n-Fix issues that can cause IOEDC error.\n-Fix issues that can cause drive assert condition.\n-Fix issues that can cause drive hang condition.\n-Fix issues that can cause drive-not-ready.\n-Fix issues that can cause command timeout.\nEnhancements:\n- Increase the background scan interval timer value.\n- Improve reliability feature execution under highly localized workloads.\n- Improve performance or reduce latency for certain workloads.\n- Improve status/error logging and reporting accuracy.\n- Improve SATA protocol compliance."
    },
    {
      "id": "5e79a0ae39f437434e9bd58784c7071caaee4797b0d14a175c5a54b2c9ca82d3",
      "name": "Seagate KT3C for model number(s) ST900MP0026, ST600MP0036 and ST300MP0026",
      "version": "KT3C",
      "release_id": "JMP8Y",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:11Z",
      "released": "2023-08-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10267689M/2/SAS-Drive_Firmware_JMP8Y_WN64_KT3C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JMP8Y",
      "size": 12327328,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Kestrel 512n ISE.  Model Numbers ST900MP0026, ST600MP0036, ST300MP0026.\nFix FW to address drive not ready and self test issues.",
      "revision_history": "- Fix for potential drive-not-ready during boot up.\n- Fix for drive reporting incorrect progress on extended background self test."
    },
    {
      "id": "121c2c65e1e9a03b00d25ba579c34f484234d576609fe0ed7e6c5860d47a0e0b",
      "name": "Samsung PM1643a drives for FW DSA4 for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "version": "DSA4",
      "release_id": "D7RNT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:05:17Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08612628M/2/SAS-Drive_Firmware_D7RNT_WN64_DSA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D7RNT",
      "size": 11328112,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1643a drives for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "f9290eb3b74efc450be944a10ae52b87ef4989382da72c3cd6b1a85e58859631",
      "name": "Seagate 3D03  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "version": "3D03",
      "release_id": "NKGWD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:03:59Z",
      "released": "2022-12-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09072701M/2/SAS-Drive_Firmware_NKGWD_WN64_3D03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKGWD",
      "size": 11993080,
      "reboot_required": false,
      "description": "This release contains firmware version 3D03 Seagate  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "revision_history": "Fixes:\nFix the drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can make the drive return 0B/44 to all commands until power cycled.\nFix issues that can cause drive assert.\nFix issues that can cause command timeout.\nFix issues that can cause drive-not-ready, including the case that can happen after power-cycle.\nFix issues that can cause drive hang condition.\nEnhancements:\nImprove error logging/sense data reporting."
    },
    {
      "id": "7befc05c945f5c3f654ebd22984277341f826f5c59d0f9290977ad0b4488cfa7",
      "name": "Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "version": "EK06",
      "release_id": "GTG81",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-17T06:10:13Z",
      "released": "2024-01-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11140543M/1/SAS-Drive_Firmware_GTG81_WN64_EK06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GTG81",
      "size": 12131264,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "revision_history": "Fixes:\n- Addresses an issue that could cause occasional read errors"
    },
    {
      "id": "5d8c2335761f5dc729d22a939ccc164e23f6c99632d2615b1482961702fec308",
      "name": "HGST KU45  for model number(s) HUS726020ALS210 and HUS726040ALS210.",
      "version": "KU45",
      "release_id": "68X4C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T17:03:19Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150772M/2/SAS-Drive_Firmware_68X4C_WN64_KU45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=68X4C",
      "size": 11746544,
      "reboot_required": false,
      "description": "This release contains firmware version KU45  for HGST drives. Vendor model numbers HUS726020ALS210 and HUS726040ALS210.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "5ea8c7f795f37f1474f7bde4e7761aa8d1ed11e034fc56a893a5ddbc7d9bc272",
      "name": "EH0D for MG06 model number(s) MG06SCA600EY, MG06SCA800EY, MG06SCA10TEY, MG06SCA10TAY, MG06SCA600AY and MG06SCA800AY",
      "version": "EH0D",
      "release_id": "4G5GY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:59:38Z",
      "released": "2022-03-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08099094M/2/SAS-Drive_Firmware_4G5GY_WN64_EH0D_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4G5GY",
      "size": 11610000,
      "reboot_required": false,
      "description": "This release contains firmware version EH0D for MG06 model number(s) MG06SCA600EY, MG06SCA800EY, MG06SCA10TEY, MG06SCA10TAY, MG06SCA600AY and MG06SCA800AY.",
      "revision_history": "Fixes:\n- Fix an issue where an unexpected power loss can cause unrecoverable read error on the following power up."
    },
    {
      "id": "bb82cbf99973004ad4fa46b9d064ac1b23ea7e421990eef9b1994703259e53e1",
      "name": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095",
      "version": "CPE9",
      "release_id": "RRWVT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:56:16Z",
      "released": "2023-09-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10235085M/2/SAS-Drive_Firmware_RRWVT_WN64_CPE9_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RRWVT",
      "size": 12063856,
      "reboot_required": false,
      "description": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095,XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n- Fix drive detection issue.\n\nEnhancements:\n- Enable new DPN for 7.68TB capacity."
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "51252624b4929e0e9c705e59c55fca91ae5867bfb2b5bb21680df2b58fd499d0",
      "name": "Windows Server 2019 Driver 2.61.48.00 for HBA10-11 Controllers",
      "version": "2.61.48.00",
      "release_id": "WFV95",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-01-05T04:18:59Z",
      "released": "2023-03-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09649518M/2/SAS-Non-RAID_Driver_WFV95_WN64_2.61.48.00_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WFV95",
      "size": 6524184,
      "reboot_required": true,
      "description": "This release updates Windows 2019 Server driver to 2.61.48.00 for HBA345 Adapter/Front, HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter/MX/MM/MMLP Controllers.",
      "revision_history": "N/A"
    },
    {
      "id": "1422bba58673005e0d8a1f7d9ee1c898c81706f760e54c181b8a463dce6c5e22",
      "name": "Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "version": "BJ07",
      "release_id": "5WMK8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:21:19Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933394M/1/SAS-Drive_Firmware_5WMK8_WN64_BJ07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5WMK8",
      "size": 12038824,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "d8437b996ac697e05d66eea0c991e755d0142e2a4dbf3d2ad3bd95a4feb929d3",
      "name": "Intel NIC Family Version 22.0.0 Drivers for Windows Server 2019 and 2022 Operating Systems",
      "version": "22.0.0",
      "release_id": "X9PPT",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-13T18:44:32Z",
      "released": "2023-03-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09683951M/2/Network_Driver_X9PPT_WN64_22.0.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9PPT",
      "size": 44210816,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "Fixes\n=====\n- Resolved an issue where ETrackID, NVM Version, and FW Version field information was missing\n  in ProSet for X710, XL710, and XXV710 adapters. {242553}\n- Resolved an issue where on Windows Server OSs with Intel(R) Ethernet 25G 2P E810-XXV-k Mezz\n  adapters, hardware diagnostic tests using PROSet ACU would cause errors. {240055}\n\nEnhancements\n=====\n- Introduces performance counters manifest file for Intel (R) E810 devices, which can be imported into the \n  Microsoft Windows utility PerfMon. {D3752}"
    },
    {
      "id": "c855860fcea8e28b218e1a411e459df231843af673b1b74063fb0651ac68c681",
      "name": "Windows Server 2022 Driver 7.726.01.00 for PERC Controllers",
      "version": "7.726.01.0",
      "release_id": "WC00M",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-02T22:19:12Z",
      "released": "2023-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10807838M/1/SAS-RAID_Driver_WC00M_WN64_7.726.01.0_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WC00M",
      "size": 6194480,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver to 7.726.01.0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers."
    },
    {
      "id": "1bd85f6bd394bc927689e01db4206561ec946a6b01a7579299d2a9ee26ef0920",
      "name": "Windows Server 2019 Driver 7.726.01.0 for PERC Controllers",
      "version": "7.726.01.0",
      "release_id": "44R58",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-02T22:15:59Z",
      "released": "2023-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10807826M/1/SAS-RAID_Driver_44R58_WN64_7.726.01.0_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=44R58",
      "size": 6196192,
      "reboot_required": true,
      "description": "This release updates Windows 2019 Server driver to 7.726.01.0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers."
    },
    {
      "id": "3e6433d387935a61626c4c49d78e992bbd48dcbd023e5e824374f6c97ced803b",
      "name": "PERC H740P/ H745 RAID Controller Firmware 51.16.0-5150",
      "version": "51.16.0-5150",
      "release_id": "96M5G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-09-29T13:41:58Z",
      "released": "2023-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10676343M/1/SAS-RAID_Firmware_96M5G_WN64_51.16.0-5150_A17.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=96M5G",
      "size": 21963976,
      "reboot_required": true,
      "description": "This release updates the firmware residing on PERC H740P, H840, and H745 controllers to package 51.16.0-5150",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions.\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown of the system to enable the new memory settings. A warm reboot will NOT activate the updated settings. If iDrac/LC is used to perform the update, a graceful shutdown after the update is still required.\n\nFirmware downgrade below 50.3.0-1022 is not supported without assistance from Dell due to the potential of data loss if steps are not performed correctly.\n-Call Dell technical support for guidance if this is required.\n\nFirmware downgrade from version 50.5.0-1750 or greater to a lower version while in Enhanced -HBA mode is not supported.\nFirmware downgrade from version 50.5.1-2633 or greater to a lower version while in OpenManage Secure Enterprise Key Manager mode is not supported.\n-H745 PERC controllers only support firmware version 50.9.2-2938 or greater"
    },
    {
      "id": "f00b0fb442568fef33a6e6b6f803cb2d327c1864b57c2f40c77208c11a0cff75",
      "name": "Intel NIC Family Version 22.5.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "22.5.7",
      "release_id": "1R0W0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T21:01:32Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646142M/1/Network_Firmware_1R0W0_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1R0W0",
      "size": 36581360,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "fe3df57f88a24821dcfe6da938dea1cb5969fd93d89df900376eb41cf1b3ac98",
      "name": "Intel NIC Family Version 22.5.0 Firmware for I350, I354, and X550 Adapters",
      "version": "22.5.7",
      "release_id": "TNXW1",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T20:37:20Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646092M/2/Network_Firmware_TNXW1_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TNXW1",
      "size": 16735312,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "1b93b4e39384176023ffc076dcc78d84a5de9901d76ecc2d947776c3d6934cfe",
      "name": "Windows Server 2022 Driver 2.61.48.00 for HBA10-11 Controllers",
      "version": "2.61.48.00",
      "release_id": "M2P63",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-09-22T12:09:30Z",
      "released": "2023-03-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09649533M/5/SAS-Non-RAID_Driver_M2P63_WN64_2.61.48.00_A02_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M2P63",
      "size": 6527320,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver to 2.61.48.00 for HBA345 Adapter/Front, HBA355i Adapter/Front, HBA355e Adapter, HBA350i Adapter/MX/MM/MMLP Controllers.",
      "revision_history": "NA"
    },
    {
      "id": "464b59fe39812588c5713e0530dbe62d1c68c051dda5e2cf1656c70d85840571",
      "name": "Micron 5300 SED J808 firmware for model number MTFDDAK7T6TDS",
      "version": "J808",
      "release_id": "7X7KX",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-08-04T09:11:19Z",
      "released": "2023-08-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10433234M/1/Serial-ATA_Firmware_7X7KX_WN64_J808_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7X7KX",
      "size": 11866584,
      "reboot_required": false,
      "description": "This  release contains  firmware for Micron 5300 SED drives (7.68TB capacity).  Firmware version J808 for Micron 5300 SED drives, model MTFDDAK7T6TDS..",
      "revision_history": "Fixes:\n-Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "76674cab6905ca47390a6c1e7bf9e87dd29131446ae0c25e99d2c4ebaaa5688a",
      "name": "Micron J808 Firmware for model number  MTFDDAK7T6TDS .",
      "version": "J808",
      "release_id": "5FYJD",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2023-06-30T09:11:18Z",
      "released": "2023-06-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10269954M/1/Serial-ATA_Firmware_5FYJD_WN64_J808_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5FYJD",
      "size": 11866552,
      "reboot_required": false,
      "description": "This release contains firmware version J808 for Micron drives. Vendor model number MTFDDAK7T6TDS.",
      "revision_history": "Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "9def27dec47cc2397036ee572890022b15e5dc0fc6e054dcfb6ffedc29b1ef59",
      "name": "Micron J008 for MTFDDAV240TDU, MTFDDAV240TDS, MTFDDAV480TDS, MTFDDAV960TDS, MTFDDAV1T9TDS,  MTFDDAK240TDS, MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS,MTFDDAK240TDT, MTFDDAK480TDT, MTFDDAK960TDT, MTFDDAK1T9TDT",
      "version": "J008",
      "release_id": "KT63Y",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2023-06-30T09:07:13Z",
      "released": "2023-06-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10269881M/1/Serial-ATA_Firmware_KT63Y_WN64_J008_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KT63Y",
      "size": 12137648,
      "reboot_required": false,
      "description": "Micron J008 for MTFDDAV240TDU, MTFDDAV240TDS, MTFDDAV480TDS, MTFDDAV960TDS, MTFDDAV1T9TDS,  MTFDDAK240TDS, MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS,MTFDDAK240TDT, MTFDDAK480TDT, MTFDDAK960TDT, MTFDDAK1T9TDT",
      "revision_history": "Fixes for FW assert issue and power loss handeling issue."
    },
    {
      "id": "7f3c1816a8abb0d5de05c5772def174d0e1ae5f6c9c2ad5523fd664903346ed8",
      "name": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "version": "CSJA",
      "release_id": "J12RT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-06-30T05:01:47Z",
      "released": "2023-06-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10268173M/1/SAS-Drive_Firmware_J12RT_WN64_CSJA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J12RT",
      "size": 12687840,
      "reboot_required": false,
      "description": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSJ8."
    },
    {
      "id": "477ae0e56ed29128c0a723d01f5edf8737a96d8c6f711640707686489acfe7e4",
      "name": "Dell 14G /15G Internal Dual SD Module",
      "version": "2.0",
      "release_id": "X4K6X",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2023-03-02T17:15:36Z",
      "released": "2022-01-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08106962M/2/Firmware_X4K6X_WN64_2.0_A06_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X4K6X",
      "size": 6142176,
      "reboot_required": true,
      "description": "Internal Dual SD Module Firmware Update"
    },
    {
      "id": "d6784baaf602be53256144a13d13ccebfe0dd5110a4cb33a3573fb5e5f7f467f",
      "name": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "version": "CPE6",
      "release_id": "2PY92",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-12-14T07:32:22Z",
      "released": "2022-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09346116M/1/SAS-Drive_Firmware_2PY92_WN64_CPE6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2PY92",
      "size": 12209992,
      "reboot_required": false,
      "description": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n-Initial Release"
    },
    {
      "id": "f4a150703d9d04b786eb6c25b0d0e1f20cf5ddef7c25d7e8e286718875c5648b",
      "name": "Intel NIC Family Version 21.5.0 Drivers for Windows Server 2019 and 2022 Operating Systems",
      "version": "21.5.0",
      "release_id": "7N9PV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2022-09-08T18:05:36Z",
      "released": "2022-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08966610M/2/Network_Driver_7N9PV_WN64_21.5.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7N9PV",
      "size": 44578616,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt."
    },
    {
      "id": "27ea407c83dc92f02b1d6fd8458331571b111a4b1b8b129f7c9a8b86e7c4f1ef",
      "name": "Toshiba EJ09 for MG08 model number(s) MG08SCA16TEY",
      "version": "EJ09",
      "release_id": "9N3RR",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-08-18T08:52:06Z",
      "released": "2022-08-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08893938M/1/SAS-Drive_Firmware_9N3RR_WN64_EJ09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9N3RR",
      "size": 12479016,
      "reboot_required": false,
      "description": "This release contains firmware version EJ09 for MG08 model number(s) MG08SCA16TEY.",
      "revision_history": "Fixes:-\nAddresses an issue that could cause occasional read errors"
    },
    {
      "id": "6b01a365cd3ec211f0220c2550d15f29848832f62579e2e64a7467874c94f2fa",
      "name": "Seagate 4D0C for model number(s) XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "version": "4D0C",
      "release_id": "NX13G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-04-28T10:32:00Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486562M/1/SAS-Drive_Firmware_NX13G_WN64_4D0C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NX13G",
      "size": 11833104,
      "reboot_required": false,
      "description": "This release contains firmware version 4D0C for Seagate drives. Vendor model numbers XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "revision_history": "Fixes:\nFix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can return corrupt data after a power cycle in a corner case.\nFix an issue that can return the sense code 09/80/00 to a WRITE command.\nFix issues that can cause command timeout.\nFix issues that can cause drive assert.\nFix issues that can cause drive hang condition.\nFix an issue that can cause drive-not-ready.\nEnhancements:\nImprove protocol spec compliance.\nImprove throughput performance for specific workloads.\nImprove error logging/sense data reporting."
    },
    {
      "id": "e4c618754eb7591a6a4e57d3c39ecca8351d1794ba7b4ab8de43d6466ac16649",
      "name": "Broadcom NetXtreme network device firmware, 22.0",
      "version": "22.00.6",
      "release_id": "DFF48",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2022-01-07T05:56:55Z",
      "released": "2022-01-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08077841M/1/Network_Firmware_DFF48_WN64_22.00.6.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DFF48",
      "size": 6835704,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for Broadcom NetXtreme devices.   This release should be used with the Broadcom 21.8.2 device drivers.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for new LOM devices.."
    },
    {
      "id": "2ea2748e5a817413862cea6456c7c329059a045806cd1465168a7274a04871f0",
      "name": "Seagate PT55 for model number(s) ST8000NM0185.",
      "version": "PT55",
      "release_id": "6421F",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-12-15T06:15:22Z",
      "released": "2021-12-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08018016M/1/SAS-Drive_Firmware_6421F_WN64_PT55_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6421F",
      "size": 10934392,
      "reboot_required": false,
      "description": "This release contains firmware version PT55 for supplier model number ST8000NM0185.",
      "revision_history": "Fixes:\n- Fix an issue that can make the drive unresponsive following a Hard Reset during writes.\n- Fix issues that can cause command timeout.\n- Fix issues that can cause Assert condition.\n- Fix an issue that can cause IOEDC error.\n\nEnhancements:\n- Improve performance for certain workloads.\n- Improve error logging / sense code reporting accuracy.\n- Improve SAS spec compliance."
    },
    {
      "id": "0d641577c496dd28e779754196b55a19c1f613a33f3548ee9658a2eb909b215a",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 21.8.2",
      "version": "21.90.2",
      "release_id": "KVNHP",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2021-09-16T23:45:53Z",
      "released": "2021-09-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07742211M/1/Network_Driver_KVNHP_WN64_21.90.2_218.0.300.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KVNHP",
      "size": 36641816,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for Windows Server 2022"
    },
    {
      "id": "80318ba926a22165790009e8aa0a953888eeddac60c085b60146da569d6c5aa9",
      "name": "Intel NIC Family Version 20.5.0 Ethernet Driver",
      "version": "20.5.0",
      "release_id": "2YNFG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2021-07-08T17:20:16Z",
      "released": "2021-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07537990M/1/Network_Driver_2YNFG_WN64_20.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2YNFG",
      "size": 43279168,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update. Please extract the release note \"release.txt\" to find the supported adapters by this software bundle.",
      "revision_history": "Fixes and Enhancements are located in the associated \"release.txt\" file."
    },
    {
      "id": "9f54d16b6a912067843cc2bd8568d7b9c3911cac62f7725298299613a5828fca",
      "name": "Seagate Lange Firmware Version EC16  for model number(s) XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "version": "EC16",
      "release_id": "H3VHX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-02-04T09:29:43Z",
      "released": "2021-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07035193M/1/SAS-Drive_Firmware_H3VHX_WN64_EC16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3VHX",
      "size": 10683112,
      "reboot_required": false,
      "description": "This release contains firmware version EC16 for Seagate drives. Vendor model numbers XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "revision_history": "Fixes:\n-Fix an issue where reading or writing of corrupt data can result after a power cycle\n-Fix an issue which can lead to reduced data retention duration\n-Fix an issue where assert can result when max. queue depth is exceeded\n-Update activity LED blinking behavior to be consistent with Dell requirements\n\nEnhancements:\n-N/A"
    },
    {
      "id": "b0982adc7c4c0f8266dc8f0568692e5a400f3ba3a83afc512ca5ef83dbd78cf5",
      "name": "Toshiba GA09 for model number(s) MG06ACA10TEY, MG06ACA800EY and MG06ACA600EY.",
      "version": "GA09",
      "release_id": "PT7D8",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-12-11T14:43:20Z",
      "released": "2020-12-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06874149M/1/Serial-ATA_Firmware_PT7D8_WN64_GA09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PT7D8",
      "size": 10709208,
      "reboot_required": false,
      "description": "This package contains firmware version GA09 for Toshiba drives (vendor model numbers MG06ACA10TEY, MG06ACA800EY and MG06ACA600EY).",
      "revision_history": "-Applied the feature of reverse sequential read.\n-Improved performance for 2MiB random read random write and mixed read 70 percentage write 30 percentage\n-Changed aging time from 900ms to 1900ms the value is same as  in order to improve random access performance.\n-Improved algorithms of cache preservation."
    },
    {
      "id": "5b978148232ea8a9cc141a5a3efc6c32234a86de2fa3c6b8717b390c9c06b127",
      "name": "HGST LT20  for model number(s) HGST HUH721008ALE600, HGST HUH721010ALE600.",
      "version": "LT20",
      "release_id": "65D08",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2020-12-07T05:47:11Z",
      "released": "2020-11-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06855978M/1/Serial-ATA_Firmware_65D08_WN64_LT20_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=65D08",
      "size": 11485312,
      "reboot_required": false,
      "description": "This release contains firmware version LT20  for HGST drives. Vendor model numbers HGST HUH721008ALE600, HGST HUH721010ALE600.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "8ceef66f6383dfe9b716f4c3f2b8518b194de729bd18cef56b63268e3e226b6f",
      "name": "HGST LS20 for model number(s) HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.",
      "version": "LS20",
      "release_id": "XYKWH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2020-11-18T05:01:14Z",
      "released": "2020-11-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06799321M/1/SAS-Drive_Firmware_XYKWH_WN64_LS20_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XYKWH",
      "size": 11457376,
      "reboot_required": false,
      "description": "This release contains firmware version LS20 for HGST drives. Vendor model numbers HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "b3bdd43b335a4c8a9d5e29d4e9b3c87f0b9b07ce533b4d1e7eeb0fe813120f70",
      "name": "Toshiba GB03 for MG07 ISE model number(s) MG07ACA14TEY and  MG07ACA12TEY",
      "version": "GB03",
      "release_id": "0942Y",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2020-06-23T06:41:48Z",
      "released": "2020-06-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06333095M/1/Serial-ATA_Firmware_0942Y_WN64_GB03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0942Y",
      "size": 10677472,
      "reboot_required": false,
      "description": "This release contains firmware version GB03 for Toshiba MG07 ISE drives - Vendor model number(s) MG07ACA12TEY and MG07ACA14TEY",
      "revision_history": "- Improved the performance for 100MB Random Read/Write.\n- Improved performance for ShortRange Access.\n- Improved performance for ShortRange Access.\n- Fixed the hang by read data xfer in the case of receiving COMRESET.\n- Fixed hang up issue if deep Read Retry occurs and then seek error occurs at the timing when corresponded retry sector is read.\n- Fixed the response of SECURITY ERASE UNIT in the case of following confition.The drive should execute SECURITY ERASE UNIT command only when SECURITY ERASE PREPARE command issues just before SECURITY ERASE UNIT command. If there is any other commands between SECURITY ERASE PREPARE command and SECURITY ERASE PREPARE command,the drive should issue abort. However drive responded normally at even this condition.\n- Improved recovery function when multiple intrenal log broken at power on.\n- Improved the intrenal log loading seqeunce at online FW download.\n- Fixed the internal log loading count at online FW download.\n- Supported for P11 temperature reporting features.\n- Fixed the hang by DownloadMicode CMD in the case of receiving COMRESET.\n- Fixed the issue of internal hang  when Security Erase Unit CMD was recieved from host by unAlign LBA.\n- Fixed the write data currupt when pre-read occurred error in non-Align Access.\n- Added Reverse sequential read Function.\n- Fixed the hang when UnCorrectable error occured at read data transfer.\n- Improved internal que latency at refresh write.\n- improved partial/slumber state time.\n- Changed attribute value ID=5,197 from 512byte unit to 4K byte unit.\n- Improved the performance for 2MB Random Read/Write Mix R70/W30.\n- Fixed the SCT Timeout issue caused by badly management of cache in the case of repetition write to same address.\n- Change interval time for DST to start from 0ms to 500ms.\n- Fixed the NCQ Command response at standby state."
    },
    {
      "id": "8b261aa1080cecb64c8ca48e687208602108b4d5ae173c8fa46965296fc0a633",
      "name": "Matrox Video Driver",
      "version": "4.4.0.4",
      "release_id": "N1HM4",
      "category": "Video",
      "category_slug": "video",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2019-10-22T05:43:09Z",
      "released": "2018-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05278833M/5/Video_Driver_N1HM4_WN64_4.4.0.4_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N1HM4",
      "size": 6189248,
      "reboot_required": true,
      "description": "This package contains the Matrox Video driver. A graphics or video driver is the software that enables communication between the graphics card and the operating system, games, and applications.",
      "revision_history": "Initial Release"
    },
    {
      "id": "ba426f4c15eba3ef3f366e9a3f3e89c57a8fb259998177ff1208cd9dbe1862a5",
      "name": "Samsung DSF8 for model number(s) MZILT960HAHQ0D3, MZILT1T9HAJQ0D3, MZILT3T8HALS0D3, MZILTZ7T6HMLA0D3, and MZILT15HMLA0D3.",
      "version": "DSF8",
      "release_id": "PFPV9",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-09T09:45:32Z",
      "released": "2019-01-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05403504M/1/SAS-Drive_Firmware_PFPV9_WN64_DSF8_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PFPV9",
      "size": 10590416,
      "reboot_required": false,
      "description": "This release contains firmware version DSF8 for Samsung drives. Vendor model numbers MZILT960HAHQ0D3, MZILT1T9HAJQ0D3, MZILT3T8HALS0D3, MZILTZ7T6HMLA0D3, and MZILT15HMLA0D3."
    }
  ]
}