  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r340",
  "name": "R340",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R340 SAS RAID Updates",
  "filter": "sas-raid",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 48,
      "rss": "/r340/urgent/rss.xml",
      "api": "/api/r340/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 139,
      "rss": "/r340/recommended/rss.xml",
      "api": "/api/r340/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 38,
      "rss": "/r340/optional/rss.xml",
      "api": "/api/r340/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r340/bios/rss.xml",
      "api": "/api/r340/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/r340/chipset/rss.xml",
      "api": "/api/r340/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/r340/diagnostics/rss.xml",
      "api": "/api/r340/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r340/drivers-for-os-deployment/rss.xml",
      "api": "/api/r340/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 8,
      "rss": "/r340/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r340/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 7,
      "rss": "/r340/fibre-channel/rss.xml",
      "api": "/api/r340/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 2,
      "rss": "/r340/firmware/rss.xml",
      "api": "/api/r340/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r340/idrac/rss.xml",
      "api": "/api/r340/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 24,
      "rss": "/r340/network/rss.xml",
      "api": "/api/r340/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 92,
      "rss": "/r340/sas-drive/rss.xml",
      "api": "/api/r340/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 4,
      "rss": "/r340/sas-non-raid/rss.xml",
      "api": "/api/r340/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 12,
      "rss": "/r340/sas-raid/rss.xml",
      "api": "/api/r340/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 66,
      "rss": "/r340/serial-ata/rss.xml",
      "api": "/api/r340/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r340/systems-management/rss.xml",
      "api": "/api/r340/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/r340/video/rss.xml",
      "api": "/api/r340/video"
    }
  ],
  "count": 12,
  "updates": [
    {
      "id": "fd473c28f7250f2c6d18913dc3111f4d695b92c719953f933d5de9f4f624cd1b",
      "name": "Dell PERC H330 Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "NYKX7",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:21:18Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07211734M/4/SAS-RAID_Firmware_NYKX7_WN64_25.5.9.0001_A15_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NYKX7",
      "size": 25051800,
      "reboot_required": true,
      "description": "Dell PERC H330 Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "5c912c46b71cf36439ff040f72dfd483a636caf6953566b7822e906ce3a8e030",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "version": "25.5.8.0001",
      "release_id": "WRF3Y",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:12:44Z",
      "released": "2020-09-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06547525M/4/SAS-RAID_Firmware_WRF3Y_WN64_25.5.8.0001_A16_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WRF3Y",
      "size": 25507720,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "revision_history": "Fixes:\n-Fixed an isolated issue where manually run controller self-diagnostics would trigger Event 13 (Controller cache discarded due to firmware version incompatibility) on the subsequent reboot.\n\nEnhancements:\n-Enhanced Background Initialization (BGI) and Consistency Check (CC) progress to reduce performance impact when progress is saved (checkpointed).\n  Previous behavior:\n    BGI/CC progress was saved to disk every 5 minutes, this disk access triggered I/O to pause and cache flush, causing a latency increase.\n   New behavior (as of 25.5.8.0001):\n    BGI/CC progress was saved to disk every 5 minutes if an operating system/driver is not loaded.\n          Note: H330 controllers will keep background operations paused while in HII, or until an OS is loaded.\n    When the firmware detects a driver loading, BGI/CC progress will be saved every 4 hours.\n    When a graceful shutdown is performed, the firmware will save progress as part of the shutdown procedure.\n    In the event of ungraceful shutdown/power loss progress will resume from the last saved checkpoint.\n          Note: Progress Events remain unchanged and will be observed at the same interval."
    },
    {
      "id": "493d6478a65cc15bfbb6c50488217952ef5f4c79a9bf9c593c18ece67ef5ed3e",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "700GG",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-05T16:45:15Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07217671M/3/SAS-RAID_Firmware_700GG_WN64_25.5.9.0001_A17_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=700GG",
      "size": 25505712,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "ddd0e2c51b4580eb2778870b68324d237a03ac014aa8e6f1d071efa03f75333c",
      "name": "BOSS-S2 Firmware",
      "version": "2.5.13.4009",
      "release_id": "TTR5R",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-25T07:01:26Z",
      "released": "2023-02-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09232098M/7/SAS-RAID_Firmware_TTR5R_WN64_2.5.13.4009_A01_06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TTR5R",
      "size": 22410088,
      "reboot_required": true,
      "description": "BOSS-S2 ROM version 2.5.13.4009",
      "revision_history": "Fixes:\n\n-- Addressed false M.2 failures reported due to thermal issues \n               \nEnhancements:\n-- Added new SDID 0x2261 on BOSS-S2 controller"
    },
    {
      "id": "40a5d823af38ca2ebe7cbf8287901fe09aafe6fca47e6048df8429e0f104815d",
      "name": "Microsoft Windows x64 management driver for BOSS",
      "version": "1.2.0.1052",
      "release_id": "8KKVC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-31T12:12:02Z",
      "released": "2021-07-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07524633M/9/SAS-RAID_Driver_8KKVC_WN64_1.2.0.1052_A02_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8KKVC",
      "size": 17014984,
      "reboot_required": false,
      "description": "Microsoft Windows x64 management driver for BOSS",
      "revision_history": "Fixes: None,\nEnhancements: YES , Signed Binaries\nConsole Management Driver for all Windows Operating systems\nSupport for Windows Azure HCI Stack \u0026 Windows 2022 enabled"
    },
    {
      "id": "1aa67fe97be9b69f74c41d082bf3193e5c0511a1cbaac86f436a4b56b04d5149",
      "name": "BOSS-S1 Adapter firmware",
      "version": "2.5.13.3024",
      "release_id": "3P39V",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-28T11:06:39Z",
      "released": "2020-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06189651M/8/SAS-RAID_Firmware_3P39V_WN64_2.5.13.3024_A07_07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3P39V",
      "size": 23542088,
      "reboot_required": true,
      "description": "BOSS-S1 Adapter ROM version 2.5.13.3024",
      "revision_history": "Fixes:YES\nFixed PPID Discrepancy for M.2 drives of BOSS controller in iDRAC Hardware inventory page\nFixed an issue to resolve the Offline Bundle installation of ESXi 6.x CLI via VUM\nFixed a behavior in firmware to handle when create \u0026 delete VD command execute in loop.\nEnhancements:YES\nNew unified BOSS Console/Management driver for all Windows operating systems."
    },
    {
      "id": "e030fecbf94eb9512ae1dfa4fb776046fd4612d06268cb14e6909c5d697489ae",
      "name": "BOSS-S1 Modular firmware",
      "version": "2.6.13.3025",
      "release_id": "F9F16",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-27T11:07:40Z",
      "released": "2023-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09214778M/11/SAS-RAID_Firmware_F9F16_WN64_2.6.13.3025_A08_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F9F16",
      "size": 23542872,
      "reboot_required": true,
      "description": "BOSS-S1 Modular ROM version 2.6.13.3025",
      "revision_history": "Fixes : HW Re-spin \nAddressed false M.2 failures reported due to thermal issues\n\nEnhancements : Added new SDID 0x2260 on BOSS-S1 controller"
    },
    {
      "id": "9919a72526e3192f77c158c625e5ec4efa06638905b3c239de5820e669db369e",
      "name": "BOSS Console Management driver for WS2022-2025",
      "version": "1.2.0.1055",
      "release_id": "7004G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-12-18T11:18:14Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11846807M/2/SAS-RAID_Driver_7004G_WN64_1.2.0.1055_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7004G",
      "size": 12936864,
      "reboot_required": false,
      "description": "BOSS Console Management driver for WS2022-2025",
      "revision_history": "Fixes: None,\nEnhancements: Console Management Driver enablement for MS Windows 2025."
    },
    {
      "id": "c262b14586cfb8f23d28fd4fce1526b82bc29af8589298cb407fb7b8956acf5b",
      "name": "Windows Server 2022 64bit driver for PERC S140 Controller",
      "version": "5.11.0.0003",
      "release_id": "85R54",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T17:21:48Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422921M/1/SAS-RAID_Driver_85R54_WN64_5.11.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=85R54",
      "size": 6633192,
      "reboot_required": true,
      "description": "Windows Server 2022 64bit driver for PERC S140 Controller"
    },
    {
      "id": "c1ad7f22b60acedb99114f7c68abbc599cad01da466bb6ed704a1888f7280388",
      "name": "Windows Server 2019 64bit driver for PERC S140 Controller",
      "version": "5.11.0.0003",
      "release_id": "P74H3",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T17:21:17Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422918M/1/SAS-RAID_Driver_P74H3_WN64_5.11.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P74H3",
      "size": 6632656,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S140 Controller"
    },
    {
      "id": "0e605d9211bcd8a02a879473d78eea4e314ae0715828727db3f5114b6575d264",
      "name": "PERC H740P/H840/H745 RAID Controller Firmware 51.16.0-4076",
      "version": "51.16.0-4076",
      "release_id": "F3J22",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-21T23:49:16Z",
      "released": "2021-07-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07551659M/2/SAS-RAID_Firmware_F3J22_WN64_51.16.0-4076_A16_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F3J22",
      "size": 26112328,
      "reboot_required": true,
      "description": "This release updates the firmware residing on PERC H740P, H840, and H745 controllers to package 51.16.0-4076",
      "revision_history": "Fixes: \n\n    -Fixed issue where controller would fault on boot in systems with multiple backplanes.\n    -Fixed issue where Medium Errors found on drives were not reported during rebuilds and copybacks.\n    -Fixed issue where controller would fault during a firmware downgrade.\n    -Fixed issue where Bad PHY events were incorrectly reported.\n    -Fixed issue where SATA Drives where controller would take too long to timeout a link recovery on an unresponsive drive."
    },
    {
      "id": "54f45b3e3ed95a4734d61ae1b0410bd9bdf58b64e5d771908f77aaa00e5f2b20",
      "name": "Windows Server 2016 Driver 6.604.06.00 for PERC H330/H730/H730P/H830/H730P MX/FD33xD/FD33xS Controllers",
      "version": "6.604.06.00",
      "release_id": "T244W",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-02-19T07:08:49Z",
      "released": "2016-09-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER03940499M/11/SAS-RAID_Driver_T244W_WN64_6.604.06.00_A01_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T244W",
      "size": 6848432,
      "reboot_required": true,
      "description": "Windows Server 2016 Driver 6.604.06.00 for PERC H330/H730/H730P/H830/H730P MX/FD33xD/FD33xS Controllers",
      "revision_history": "Fixes\n- N/A\n\nEnhancements\n-  Added 1MB I/O support for H730, H730P and H830 controllers."
    }
  ]
}