  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r340",
  "name": "R340",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R340 SAS Drive Updates",
  "filter": "sas-drive",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 48,
      "rss": "/r340/urgent/rss.xml",
      "api": "/api/r340/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 139,
      "rss": "/r340/recommended/rss.xml",
      "api": "/api/r340/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 38,
      "rss": "/r340/optional/rss.xml",
      "api": "/api/r340/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r340/bios/rss.xml",
      "api": "/api/r340/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/r340/chipset/rss.xml",
      "api": "/api/r340/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/r340/diagnostics/rss.xml",
      "api": "/api/r340/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r340/drivers-for-os-deployment/rss.xml",
      "api": "/api/r340/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 8,
      "rss": "/r340/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r340/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 7,
      "rss": "/r340/fibre-channel/rss.xml",
      "api": "/api/r340/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 2,
      "rss": "/r340/firmware/rss.xml",
      "api": "/api/r340/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r340/idrac/rss.xml",
      "api": "/api/r340/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 24,
      "rss": "/r340/network/rss.xml",
      "api": "/api/r340/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 92,
      "rss": "/r340/sas-drive/rss.xml",
      "api": "/api/r340/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 4,
      "rss": "/r340/sas-non-raid/rss.xml",
      "api": "/api/r340/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 12,
      "rss": "/r340/sas-raid/rss.xml",
      "api": "/api/r340/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 66,
      "rss": "/r340/serial-ata/rss.xml",
      "api": "/api/r340/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r340/systems-management/rss.xml",
      "api": "/api/r340/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/r340/video/rss.xml",
      "api": "/api/r340/video"
    }
  ],
  "count": 92,
  "updates": [
    {
      "id": "0a6a479d8442052f0ed7ecbee39b76740eab0e8b746a305ff6194e3d7220e695",
      "name": "Seagate Evans Firmware Version ESLA  for model number(s)  ST10000NM011G, ST12000NM009G, ST14000NM013G,ST16000NM010G",
      "version": "ESLA",
      "release_id": "T16JN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-10T04:27:32Z",
      "released": "2026-08-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14878500M/1/SAS-Drive_Firmware_T16JN_WN64_ESLA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T16JN",
      "size": 27626464,
      "reboot_required": false,
      "description": "Firmware Update of \"ESLA\" for Evans SAS ISE HDD.  Model numbers: ST10000NM011G, ST12000NM009G, ST14000NM013G, and ST16000NM010G.",
      "revision_history": "- FW change to address potential Drive Assert by updating the cleanup logic to handle the interrupted write data frame when the host queue happens to be active during termination cleanup sequence."
    },
    {
      "id": "05aaf2787b94f4c3658352e334d92a069cdbd2bc57150c8d9513a2190745fc22",
      "name": "This release contains firmware version CSLF for STX drives. Vendor model numbers ST6000NM035A, ST8000NM014A.",
      "version": "CSLF",
      "release_id": "C4W12",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-10T04:01:33Z",
      "released": "2026-08-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14878306M/1/SAS-Drive_Firmware_C4W12_WN64_CSLF_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C4W12",
      "size": 27698568,
      "reboot_required": false,
      "description": "Firmware Refresh of \"CSLF\" for Seagate Cimarron 512e ISE.  Vendor model number ST6000NM035A, ST8000NM014A.",
      "revision_history": "- FW change to address potential Drive Assert by updating the cleanup logic to handle the interrupted write data frame when the host queue happens to be active during termination cleanup sequence."
    },
    {
      "id": "559e792d7369318d22be9a9b8c82cb7c3e6f91193952b11ebf8a9ba38e90ab7c",
      "name": "Toshiba EF0A for model number(s) AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY",
      "version": "EF0A",
      "release_id": "THG5M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T06:27:04Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607520M/2/SAS-Drive_Firmware_THG5M_WN64_EF0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=THG5M",
      "size": 26661096,
      "reboot_required": false,
      "description": "This release contains firmware version EF0A for Toshiba drives. Vendor model numbers AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures.\n- Fixed Command timeout (or 06/29/04) issue.\n  This problem may occur when the queued time for a read or write command \n  exceeds the Command Aging Timer and the SYNCHRONIZED CACHE \n  command is also queued.\n- Fixed random write iops degradation after sequential read.\n    4k Random write -\u003e Seq read -\u003e 4k random write. In this test sequence, \n    2nd 4k random write iops may drop.\n- Fixed a wrong LBA report in SENSE DATA when Read Buffer CRC \n    error(03/11/02) occurs."
    },
    {
      "id": "fdd84063aa261dc77f4bd896bc2458570e08fd9fa0f7c7a07d843154dbc72955",
      "name": "Initial release of Toshiba AL15SE+ HDD Model Number AL15SEB09EQY",
      "version": "EF82",
      "release_id": "VJWX0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T04:21:30Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607338M/2/SAS-Drive_Firmware_VJWX0_WN64_EF82_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJWX0",
      "size": 26660216,
      "reboot_required": false,
      "description": "This release contains firmware version EF82 for Toshiba drives. Vendor Model Number AL15SEB09EQY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures."
    },
    {
      "id": "14646318eed9bac1cd8e2b6564c5b3f136a7e60b8437700c0a1d1dfa05775f75",
      "name": "Firmware update for WDC Paris-CP SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200",
      "version": "AS06",
      "release_id": "XTC10",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T06:13:54Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14472580M/1/SAS-Drive_Firmware_XTC10_WN64_AS06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XTC10",
      "size": 22713344,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP  AS06 FW SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200.",
      "revision_history": "- Firmware update to ensure the 512e Dell Model string and Dell Device ID will not show correctly when Server code is loaded over Storage code.\n- FW fix to ensure Background Media Scan timer is reset correctly when Offline Data Collection is started.\n- Code updated to ensure Component ID and Model string will report correctly after firmware upload."
    },
    {
      "id": "c73beccb3d67ad1b365735cea9aefae76310134df79570616d77bd8f290f431d",
      "name": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205",
      "version": "AM05",
      "release_id": "HTW37",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T10:16:13Z",
      "released": "2025-11-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13893761M/1/SAS-Drive_Firmware_HTW37_WN64_AM05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HTW37",
      "size": 25081440,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205.\nCode updated to fix potential issue during Dell Factory Test.",
      "revision_history": "Firmware update to address potential issue during Dell Enhanced Factory Test."
    },
    {
      "id": "b9c46d96040d3002cf5c44f7e7ab2a9b4fa8590564eb834f2797f02925f4e35a",
      "name": "FW update for of Toshiba MG09 SAS ISE.  Model numbers MG09SCA18TEY, MG09SCA16TEY, and MG09SCA12TEY",
      "version": "EM06",
      "release_id": "20Y02",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-10-21T05:49:55Z",
      "released": "2025-10-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13764807M/1/SAS-Drive_Firmware_20Y02_WN64_EM06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=20Y02",
      "size": 23534880,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG09 SAS ISE.  Model numbers MG09SCA18TEY, MG09SCA16TEY, and MG09SCA12TEY.\nFix for a Background Medium Scan issue and potential timeout.",
      "revision_history": "- Fixed a problem during Background Medium Scan or Drive Self-test in which a long read with command interrupt disabled was performed under certain conditions and other commands could not be executed.\n- Fixed the issue that could cause a SCT timeout response to fail after Flush Cache Command.\n- Fixed the issue that write commands are abnormally executed two times internally and cause BCRC error or SATA I/F protocol error."
    },
    {
      "id": "b0662e0dcea48ec11fc02672748c18c4038ef58e28c60e92dd1cc21b8f8d6bde",
      "name": "Toshiba MG08SD SAS ISE drive program for EL02 FW for model number(s): MG08SDA800EY",
      "version": "EL02",
      "release_id": "F95CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-09-03T09:09:09Z",
      "released": "2025-09-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13580189M/1/SAS-Drive_Firmware_F95CX_WN64_EL02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F95CX",
      "size": 23279080,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG08SD SAS ISE.  Model number MG08SDA800EY.\nFix for a Background Medium Scan issue and potential timeout.",
      "revision_history": "- Fixed a problem during Background Medium Scan or Drive Self-test in which a long read with command interrupt disabled was performed under certain conditions and other commands could not be executed.\n - Fixed the issue that could cause a SCT timeout response to fail after Flush Cache Command.\n - Fixed the issue that write commands are abnormally executed two times internally and cause BCRC error or SATA I/F protocol error."
    },
    {
      "id": "41d8ddf307b4ef32924e88af9618acf8165484bb258955e0c6381fffd74cec21",
      "name": "Seagate SBTA for Skybolt ServoBP program for model number(s) CL2400MM0149",
      "version": "SBTA",
      "release_id": "HH6J1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:02:18Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12677112M/2/SAS-Drive_Firmware_HH6J1_WN64_SBTA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HH6J1",
      "size": 23874432,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512n ISE. Model Number CL2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "4c6ed6166ab2e1a3e699af648e5457cd81edd18f87e2beea7561f7262fa1fa6d",
      "name": "Seagate SBSA for Skybolt ServoBP program for model number(s) BL2400MM0159",
      "version": "SBSA",
      "release_id": "00P56",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:22:58Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676520M/2/SAS-Drive_Firmware_00P56_WN64_SBSA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=00P56",
      "size": 23874416,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512e ISE.  Model Number BL2400MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "3327174b72088c6b72541588c503c14db0065a16884a08012949b2120919cf43",
      "name": "Seagate ST7G for model number(s) ST1800MM0159 and ST2400MM0159",
      "version": "ST7G",
      "release_id": "7N5DH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:05:15Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676236M/4/SAS-Drive_Firmware_7N5DH_WN64_ST7G_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7N5DH",
      "size": 23857864,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Skybolt 4Kn ISE.  Model Numbers ST2400MM0159 and ST1800MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "d5b4cea0b433c0dc5f334945213d8a951654857385c555988b21866cfaa38c0c",
      "name": "Firmware refresh for Seagate ST5J for model number(s) DL1800MM0159 and DL2400MM0159",
      "version": "ST5J",
      "release_id": "DRHV4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:02:48Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12671974M/4/SAS-Drive_Firmware_DRHV4_WN64_ST5J_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DRHV4",
      "size": 23857936,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512e ISE.  Model Numbers DL2400MM0159 and DL1800MM0159.",
      "revision_history": "Firmware modification to add support for new V8 NAND part."
    },
    {
      "id": "488b6d18b0e0ce3ac333ac5692fdf90c286b1f6fbbc6ac6a30f8212c5813f8ad",
      "name": "Firmware Update for EvansBP SAS ISE HDD. Model numbers: ST12000NM006J, ST14000NM006J, ST16000NM006J, ST18000NM006J",
      "version": "PSLG",
      "release_id": "XF65R",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:36:19Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12783645M/2/SAS-Drive_Firmware_XF65R_WN64_PSLG_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XF65R",
      "size": 23710648,
      "reboot_required": false,
      "description": "This release contains firmware version PSLG for Seagate drives. Vendor model numbers ST12000NM006J, ST14000NM006J, ST16000NM006J, ST18000NM006J.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Shorten time delay before running Direct Offline Scan"
    },
    {
      "id": "0c35e7ef25c69e2ab6c9f4c82eb0b9bba7107da2d604217f9dcd9d9848a86e2a",
      "name": "Seagate CimarronBP SAS ISE for FW LS0E for model numbers: ST8000NM024B",
      "version": "LS0E",
      "release_id": "FJ97K",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:32:22Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12816090M/2/SAS-Drive_Firmware_FJ97K_WN64_LS0E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FJ97K",
      "size": 24019096,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS ISE 512e HDD.  Model number: ST8000NM024B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "838387e0a28337097a14adabdc9607c0a6286c98d29f50a1e80938cbad0c708e",
      "name": "WDC Paris-C SAS ISE US09 for model numbers WUH721816AL5200, WUH721818AL5200",
      "version": "US09",
      "release_id": "GY6MD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-07-01T10:59:13Z",
      "released": "2025-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13323594M/1/SAS-Drive_Firmware_GY6MD_WN64_US09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GY6MD",
      "size": 25702128,
      "reboot_required": false,
      "description": "FW update for of  WDC Paris-C SAS ISE.  Model numbers WUH721816AL5200, WUH721818AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optiminum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "56221de0237fbeeb680e5eac2cb8d3e0f72799000d1986cf8fb68d7d02d297cd",
      "name": "Seagate SSEJ for model number(s) ST2400MM0149",
      "version": "SSEJ",
      "release_id": "KHJ9C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:13:51Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676334M/3/SAS-Drive_Firmware_KHJ9C_WN64_SSEJ_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHJ9C",
      "size": 24679816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512n ISE. Model Number ST2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "- Add support for Hynix V8 NAND part."
    },
    {
      "id": "9af16c01a996600f0ca7ca41fae9ce3cd6a2c5aa191bd93b4454b7d2e7ed7fba",
      "name": "Western Digital Paris-D PR2 SAS VS19 firmware for model number WUH722020BL5200",
      "version": "VS19",
      "release_id": "XRFX3",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-19T13:58:09Z",
      "released": "2025-05-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13133280M/1/SAS-Drive_Firmware_XRFX3_WN64_VS19_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XRFX3",
      "size": 27819864,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-D PR2 SAS ISE.  Model number WUH722020AL5200.\nFW improvement to remove undesired self-initiated reset as a result of statistical counter overflow.",
      "revision_history": "Remove undesired self-initiated reset which could occur when large number of messages were sent since last power cycle"
    },
    {
      "id": "94cddbcf632ba8d62bf8fd89359de9b60c19a24649fa5a370ba55cb90e9ddaad",
      "name": "Seagate CimarronBP SAS for FW LW0B for model numbers ST2000NM013B, ST4000NM019B",
      "version": "LW0B",
      "release_id": "3P5N0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-16T09:10:59Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12648511M/2/SAS-Drive_Firmware_3P5N0_WN64_LW0B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3P5N0",
      "size": 24698960,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS ISE 512n HDD.  Model numbers: ST2000NM013B and ST4000NM019B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "d78097a304bc7f406875bbadbcca8c772491a0743210d472cd14ac2ffd491dd1",
      "name": "WD Paris-C SAS FIPS firmware UM08 for model number WUH721816AL5205,WUH721818AL5205",
      "version": "UM08",
      "release_id": "GY7F4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-15T08:50:10Z",
      "released": "2023-12-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10280782M/4/SAS-Drive_Firmware_GY7F4_WN64_UM08_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GY7F4",
      "size": 25600248,
      "reboot_required": false,
      "description": "Initial release of WDC Paris-C SAS FIPS firmware version UM08 for model number WUH721816AL5205,WUH721818AL5205",
      "revision_history": "Fixes:\n- Fix for potential hang condition caused by simultaneous 'set' and 'clear' settings in the request register bit.\n- Fix for drive not able to be recovered by format when it fails to read Logical to Physical address mapping data from disk.\nEnhancements:\n- Add Log Page 0x0D parameter 0x50."
    },
    {
      "id": "ceff23d80cbb8541baa365b1fd0640fa4a06d13481f5404c1fc5497f6dbd404c",
      "name": "Seagate SSC8 for model number(s) ST1200MM0069",
      "version": "SSC8",
      "release_id": "P9R4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:08:58Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11500432M/2/SAS-Drive_Firmware_P9R4D_WN64_SSC8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P9R4D",
      "size": 24522608,
      "reboot_required": false,
      "description": "This release contains firmware version SSC8 for Seagate drives. Vendor model numbers ST1200MM0069..",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "c2499ab3befc7f8aac45f1eb2b078813e866b63b701d8296d5628475a85b6e14",
      "name": "HGST NS11 for model number(s) HUH721212AL5200 and HUH721212AL4200",
      "version": "NS11",
      "release_id": "04PM5",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:07:34Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12029572M/2/SAS-Drive_Firmware_04PM5_WN64_NS11_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=04PM5",
      "size": 24602048,
      "reboot_required": false,
      "description": "This release contains firmware version NS11 for HGST drives. Vendor model numbers HUH721212AL5200 and HUH721212AL4200.\nFW update for WDC Leo-A 512e SAS HDD, Model number HUH721212AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes. \n'FW update for WDC Leo-A 4Kn SAS HDD, Model number HUH721212AL4200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "771aacec8b2f181d2931276a870acf035ada5af80f2174a808e8f6fe28a17150",
      "name": "HGST RS09 for Vela-AP SAS  ISE model number(s) HUS728T6TAL5200, HUS728T6TAL4200",
      "version": "RS09",
      "release_id": "8GM6M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-04-11T11:06:44Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025815M/2/SAS-Drive_Firmware_8GM6M_WN64_RS09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8GM6M",
      "size": 24607448,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SAS HDD, Model number HUS728T6TAL5200.\nFW update for WDC Vela-AP 4Kn SAS HDD, Model number HUS728T6TAL4200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "9d3a909718077b49b7c8c9902c53facf85f1cfdfc24edabfce073cd264cc800c",
      "name": "Hitachi PU09 for Vela-A ISE model number(s) HUS726T4TALS200",
      "version": "PU09",
      "release_id": "J5K8G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T11:03:41Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024400M/2/SAS-Drive_Firmware_J5K8G_WN64_PU09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J5K8G",
      "size": 24727008,
      "reboot_required": false,
      "description": "FW update for WDC Vela-A 512n SAS HDD, Model number HUS726T4TALS200.\n\n- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "6cb9b2e14559a89fe993a07e8c8367a371dc1253168afd133677270b5bcb3eec",
      "name": "Seagate ST38 for model number(s) ST600MM0069 and ST1200MM0099",
      "version": "ST38",
      "release_id": "FFN16",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T10:22:22Z",
      "released": "2024-05-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11502881M/2/SAS-Drive_Firmware_FFN16_WN64_ST38_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FFN16",
      "size": 24522520,
      "reboot_required": false,
      "description": "This release contains firmware version ST38 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes:\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "b9aa8e6ec9329a8ed6c43757740d5a9727d68f2084aef6c3a616a54e28e5ca7d",
      "name": "Toshiba EI0D for MG07 model number(s) MG07SCA12TEY, MG07SCA14TEY and MG07SCA12TAY",
      "version": "EI0D",
      "release_id": "NFFHM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-06T15:14:46Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10293591M/4/SAS-Drive_Firmware_NFFHM_WN64_EI0D_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NFFHM",
      "size": 23920304,
      "reboot_required": false,
      "description": "This release contains firmware version EI0D for MG07 model number(s) MG07SCA12TEY, MG07SCA14TEY and MG07SCA12TAY.",
      "revision_history": "-Fix an issue where an unexpected power loss can cause unrecoverable read error on the following power up"
    },
    {
      "id": "5a5e3c3b8f9ad66b5a7e31fcf5b4226dd834e4fce0cca01382f0f30afa1667b9",
      "name": "Toshiba EM05 for MG09 SAS 18TB ISE model number(s) MG09SCA12TEY, MG09SCA14TEY, MG09SCA18TEY, MG09SCA16TEY",
      "version": "EM05",
      "release_id": "8829H",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-06T14:31:53Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10293717M/5/SAS-Drive_Firmware_8829H_WN64_EM05_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8829H",
      "size": 24298736,
      "reboot_required": false,
      "description": "This release contains firmware version EM04 for Toshiba MG09 SAS 18TB ISE drives Vendor model number(s) MG09SCA12TEY, MG09SCA14TEY, MG09SCA18TEY, MG09SCA16TEY",
      "revision_history": "Fixes:\n-Initial release"
    },
    {
      "id": "3b572f80f45df93fcd0e2709e4cbdb7cea0ff04b362282f708379a87f090596d",
      "name": "HGST SS08 for model number(s) WUH721414AL5200",
      "version": "SS08",
      "release_id": "61YK5",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-04T08:59:19Z",
      "released": "2024-11-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12297151M/3/SAS-Drive_Firmware_61YK5_WN64_SS08_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=61YK5",
      "size": 24812888,
      "reboot_required": false,
      "description": "'FW update for WDC Leo-B 512e SAS HDD, Model number WUH721414AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optiminum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "1a2699d84e57826d3d2d1bce8e5346834d66c2b8870ea145619ff78e3276a0f7",
      "name": "Initial release of Segate Skybolt 15ke HDD.  Model Number ST900MM0199",
      "version": "SHS1",
      "release_id": "H1W81",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-03T11:39:00Z",
      "released": "2024-10-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12162176M/2/SAS-Drive_Firmware_H1W81_WN64_SHS1_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H1W81",
      "size": 24687568,
      "reboot_required": false,
      "description": "This release contains FW revision SHS1 for model numbers ST900MM0199,",
      "revision_history": "Fix:\n\n- Initial release"
    },
    {
      "id": "184134c1a1ecf8858631bf182a7044b3ff1922ae6a878fe9c4f89795a41a6902",
      "name": "Seagate GS09 Firmware Update for Longspeak SAS ISE HDD.  Model numbers: ST18000NM007D \u0026 ST20000NM004D",
      "version": "GS09",
      "release_id": "WCTTD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-27T09:41:56Z",
      "released": "2025-01-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12915397M/1/SAS-Drive_Firmware_WCTTD_WN64_GS09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WCTTD",
      "size": 24555296,
      "reboot_required": false,
      "description": "Firmware Update for Longspeak SAS ISE HDD.  Model numbers: ST18000NM007D \u0026 ST20000NM004D.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Servo code change to address single stage actuator resonance issue in high vibe environment\n- Various performance improvements."
    },
    {
      "id": "2189d3c19f564af9c4adadb58dd81c7b80feda3edd4af1e38e757fc10724ae62",
      "name": "HGST EU46  for model number(s) HUC156030CSS200 and HUC156060CSS200",
      "version": "EU46",
      "release_id": "R39JH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T09:18:31Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12886071M/1/SAS-Drive_Firmware_R39JH_WN64_EU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R39JH",
      "size": 24103776,
      "reboot_required": false,
      "description": "This release contains firmware version EU46 FW changes to affect HGST King Cobra F 512n SAS ISE HDD, Model numbers HUC156060CSS200 and HUC156030CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "710a41520969170b139a0ad46b68638dc89b3cc9bed271ae5f33137141cd804d",
      "name": "HGST EK46 for model number(s) HUC156060CS4204",
      "version": "EK46",
      "release_id": "M04KK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T07:22:10Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12885013M/1/SAS-Drive_Firmware_M04KK_WN64_EK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M04KK",
      "size": 24112472,
      "reboot_required": false,
      "description": "This release contains firmware version EK46 'FW changes to affect HGST King Cobra F 4Kn SAS HDD, Model number HUC156060CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "be8cba2fe69053e9785264bea3fc29c4b30fe84a8cd65e095c114f2e7bbbf350",
      "name": "HGST EJ46  for model number(s) HUC156030CSS204,and HUC156060CSS204",
      "version": "EJ46",
      "release_id": "H53FC",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T06:20:55Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12884528M/1/SAS-Drive_Firmware_H53FC_WN64_EJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H53FC",
      "size": 24103728,
      "reboot_required": false,
      "description": "This release contains firmware version EJ46 'FW changes to affect HGST King Cobra F 512n SAS HDD, Model numbers HUC156060CSS204 and HUC156030CSS204.\nIncludes FW change to turn off drive usage logging to avoid pointer error",
      "revision_history": "Fixes:\nFixes: FW change to turn off drive usage logging to avoid pointer error"
    },
    {
      "id": "c69c0d7de49ad38ad0c52ed4cc69e17677fb3881869c747bd9a110e6b4c8bb73",
      "name": "HGST FU46  for model number(s) HUC101830CSS200, HUC101812CSS200 and HUC101860CSS200",
      "version": "FU46",
      "release_id": "DH7TM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T11:00:24Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880083M/1/SAS-Drive_Firmware_DH7TM_WN64_FU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DH7TM",
      "size": 24083696,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512n SAS ISE HDD, Model numbers  HUC101830CSS200, HUC101860CSS200, and HUC101812CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "cd1d62fa296afde305b57d1c8c09a670b8c62765e8c4a61a2570f61f4ffede28",
      "name": "HGST FK46 for model number(s) HUC101818CS4204 and HUC101818CS4204",
      "version": "FK46",
      "release_id": "V917M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T10:23:21Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880005M/1/SAS-Drive_Firmware_V917M_WN64_FK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V917M",
      "size": 24091240,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512e and 4Kn SAS HDD , Model number HUC101818CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\n'FW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "2f758b11765da0fb1b02a4e543dc569c690272a2b0b6e0aa0bfc0776af21817b",
      "name": "HGST FJ46  for model number(s) HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204",
      "version": "FJ46",
      "release_id": "DYYN1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T09:12:02Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12879555M/1/SAS-Drive_Firmware_DYYN1_WN64_FJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DYYN1",
      "size": 24083632,
      "reboot_required": false,
      "description": "This release contains FW changes to affect HGST Cobra F 512n SAS HDD, Model numbers HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204 includes FW change to turn off drive usage logging to avoid pointers error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointers error."
    },
    {
      "id": "134f9d13a2951baa0261de65e929e12f75351064111f853eed8ca1e7ba179f07",
      "name": "Firmware Update for Toshiba MG10 SAS. Model Number MG10SCA20TEY",
      "version": "EN04",
      "release_id": "0H3CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-11T14:39:14Z",
      "released": "2025-03-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12841970M/1/SAS-Drive_Firmware_0H3CX_WN64_EN04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0H3CX",
      "size": 24586112,
      "reboot_required": false,
      "description": "Firmware Update for Toshiba MG10 SAS.  Model Number MG10SCA20TEY.\nAdded command to update Adjacent Track Interference settings, and improved the drive retry processing.",
      "revision_history": "Fixes:\nAdded UART Command to change ATI (Adjacent Track Interference) Enable/Disable settings.\nFurther strengthened the retry process as a countermeasure against false hard error detection.\nAdded retry processing as a countermeasure against the false detection of hard errors.\nMultiple performance enhancements."
    },
    {
      "id": "5bdddd1d8557db43989a33ba11ce36bc1dd41874116c02b65d9bb1d605696706",
      "name": "Seagate CimarronBP SAS FIPS for LT0E FW for Model numbers: ST8000NM022B",
      "version": "LT0E",
      "release_id": "4T1MM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-06T06:42:36Z",
      "released": "2025-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12816183M/1/SAS-Drive_Firmware_4T1MM_WN64_LT0E_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4T1MM",
      "size": 24932568,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS FIPS 512e HDD.  Model number: ST8000NM022B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "d7206c2b27d3ad0e1f56834b43591e38e9d70e5f28690e8e8436b3199a0200dd",
      "name": "This release contains firmware version LBW4 for STX drives. Vendor model numbers DL4000NM019B",
      "version": "LBW4",
      "release_id": "M7PKX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-01-27T15:45:24Z",
      "released": "2025-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12638012M/2/SAS-Drive_Firmware_M7PKX_WN64_LBW4_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M7PKX",
      "size": 24782208,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP (EWP) SAS ISE 512n HDD.  Model number: DL4000NM019B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "3da2d1c93d40ba01200cdc48b85bb0f0a85dcb6e489b9eaa0d9d32bcbf861b9f",
      "name": "HGST PS09 for Vela-A ISE model number(s) HUS726T6TAL4200 and HUS726T6TAL5200",
      "version": "PS09",
      "release_id": "8MJFT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T07:20:39Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024641M/1/SAS-Drive_Firmware_8MJFT_WN64_PS09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8MJFT",
      "size": 13464192,
      "reboot_required": false,
      "description": "This release contains firmware version PS09 for HGST Vela-A ISE drives - Vendor model number(s) HUS726T6TAL4200 and HUS726T6TAL5200.\n'FW update for WDC Vela-A 512e SAS HDD, Model number HUS726T6TAL5200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "632cefa984ce903c90ae86afbe7b607b60915f5c751fe564c63e5b134b5be866",
      "name": "HGST NM11 for model number(s) HUH721212AL5205",
      "version": "NM11",
      "release_id": "M6T4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-08-22T15:02:58Z",
      "released": "2024-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12015224M/1/SAS-Drive_Firmware_M6T4D_WN64_NM11_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M6T4D",
      "size": 13326064,
      "reboot_required": false,
      "description": "This release contains firmware version NM11 for HGST drives. Vendor model numbers HUH721212AL5205 of capacity 12TB.\n\"FW update for WDC Leo-A 512e SAS FIPS HDD, Model number HUH721212AL5205.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.\"",
      "revision_history": "\"-Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance\""
    },
    {
      "id": "baa5cac92e3b072bd227668372c2c7520ed3e15c5a55003853c701aa0df1e8a2",
      "name": "HGST J17L for model number(s) HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "version": "J17L",
      "release_id": "0NKFF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-31T05:53:56Z",
      "released": "2024-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11625826M/3/SAS-Drive_Firmware_0NKFF_WN64_J17L_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0NKFF",
      "size": 12890680,
      "reboot_required": false,
      "description": "This release contains firmware version J17L for HGST drives. Vendor model numbers HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "revision_history": "External: FW update for HGST Bear Cove MLC 3WPD SAS HDD, Model numbers HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200, HUSMR3232ASS200.\nIncludes FW fix to free space buffer calculation to avoid a potential assert condition resulting in a self-initiated reset."
    },
    {
      "id": "2d691ed72b31c474544f0a9a0818d69f0e4ab820992ea73115f41143fafef850",
      "name": "WD BCQ firmware G138  for model numbers WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200,WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200,WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200",
      "version": "G138",
      "release_id": "8W5WF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T07:34:09Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11655805M/1/SAS-Drive_Firmware_8W5WF_WN64_G138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8W5WF",
      "size": 12585960,
      "reboot_required": false,
      "description": "This release contains firmware version G138 for WD BCQ drives. Vendor model numbers WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200, WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200, WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries."
    },
    {
      "id": "13796d98c89ff1cc8cda76d598f7dfe5ccc925a8fadfd3999fb71e9fbcb079fb",
      "name": "WDC Bear Cove Quantum FIPS-140 L138 for 1WPD and 3WPD  model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205,WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "version": "L138",
      "release_id": "16C85",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T05:58:21Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11654668M/1/SAS-Drive_Firmware_16C85_WN64_L138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=16C85",
      "size": 12580296,
      "reboot_required": false,
      "description": "This release contains firmware version L138 for WDC Bear Cove Quantum FIPS-140 1WPD and 3WPD. For model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205, WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "333f510745d6bedcbadf00dfa27e5b7532c32ae94fea09bd9ec4a93617b1329f",
      "name": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s)  KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960",
      "version": "CA0C",
      "release_id": "1YD58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T15:53:43Z",
      "released": "2023-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10810459M/2/SAS-Drive_Firmware_1YD58_WN64_CA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1YD58",
      "size": 12708760,
      "reboot_required": false,
      "description": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s) KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960G.",
      "revision_history": "Fixes: \nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed in a different area, the drive may encounter the below failure mode. Once a drive falls into this failure mode, it cannot be recovered by power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. Data buffer is used for data transfer during Wear-Leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow.                                                                                                             Write Cache Issue: An issue that may cause firmware downloads to fail in the event of a capacitor failure. This failure is triggered by firmware download in the Write Cache Off state, and even if it occurs, it does not lead to drive failure and can be recovered by a reset or Power cycle.\nCause: When FW Update is executed in the Write Cache Off state and then restarted, capacitor discharge control is activated. In this case, unintended PLP occurs because capacitor discharge was controlled in the order of capacitor discharge and then PLP interrupt mask.\nFix: When capacitor discharge control is executed after FW Update in the Write Cache Off state and the system is restarted, the PLP interrupt mask is changed to control in the order of PLP interrupt mask and then capacitor discharge."
    },
    {
      "id": "a1178484b04285ac191ec9219242d56e944c47e79f02b74de40e05534be8c7b3",
      "name": "Seagate SBW6 for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "version": "SBW6",
      "release_id": "5G3PW",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T06:30:37Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11496475M/1/SAS-Drive_Firmware_5G3PW_WN64_SBW6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5G3PW",
      "size": 13261504,
      "reboot_required": false,
      "description": "This release contains firmware version SBW6 Seagate for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "revision_history": "Fixes:\n\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "aea4393efcfda0f36a0eec8381be0d3c12daa8f85bf21fc7aca2b27303b786f8",
      "name": "Seagate Summit HDD ISE SAS SWS5 FW for model number ST12000NM007H.",
      "version": "SWS5",
      "release_id": "KVGNJ",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-04-12T09:48:59Z",
      "released": "2024-04-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11491581M/1/SAS-Drive_Firmware_KVGNJ_WN64_SWS5_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KVGNJ",
      "size": 15443480,
      "reboot_required": false,
      "description": "The initial release of Seagate Summit SAS 12TB ISE for model number ST12000NM007H.",
      "revision_history": "Fixes:\n\n- Firmware modification to reduce current required for drive spin-up.\n- Fixes for potential assert, command timeout, and drive not ready issues."
    },
    {
      "id": "fda7ed85944e9d8962289de66a326eff2cd94be829b58a3bdef99383702c6311",
      "name": "Toshiba EE0A for model number(s) AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "version": "EE0A",
      "release_id": "50N1P",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-13T11:38:43Z",
      "released": "2022-04-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08344514M/2/SAS-Drive_Firmware_50N1P_WN64_EE0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=50N1P",
      "size": 12543400,
      "reboot_required": false,
      "description": "This release contains firmware version EE0A for Toshiba drives. Vendor model numbers AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "revision_history": "Fixes:\n- Improvements that reduce the risk of media errors"
    },
    {
      "id": "8b7171c9e267a84502b4dd3b631bc09cc0e0ab25b12cc110d8273af3b0f84615",
      "name": "Seagate 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "version": "4S0C",
      "release_id": "G04C8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-12T12:12:27Z",
      "released": "2022-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08459420M/2/SAS-Drive_Firmware_G04C8_WN64_4S0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G04C8",
      "size": 12625072,
      "reboot_required": false,
      "description": "This release contains Seagate firmware version 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "revision_history": "Fixes:\n-Fix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\n-Fix an issue that can return corrupt data after a power cycle in a corner case.\n-Fix an issue that can return the sense code 09/80/00 to a WRITE command.\n-Fix issues that can cause command timeout.\n-Fix issues that can cause drive assert.\n-Fix issues that can cause drive hang condition.\n\nEnhancements:\n-Improve protocol spec compliance.\n-Improve throughput performance for specific workloads.\n-Improve error logging/sense data reporting.\n-\nFix an issue that can cause drive-not-ready."
    },
    {
      "id": "f48d1e0bb30064c3585d6c60901c49a56223945efbe756f582e821086eb712ac",
      "name": "This release contains firmware version CSFD for STX model numbers ST8000NM010A. Capacity of 8TB.",
      "version": "CSFD",
      "release_id": "6Y6YT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-12T11:56:00Z",
      "released": "2023-09-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10148510M/2/SAS-Drive_Firmware_6Y6YT_WN64_CSFD_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6Y6YT",
      "size": 13240760,
      "reboot_required": false,
      "description": "This release contains firmware version CSFD for STX model numbers ST8000NM010A. Capacity of 8TB.",
      "revision_history": "Fixes:\nFix an issue where HARD_RESET primitive sequence can be missed.\nFix an issue where stale data can be returned.\nFix an issue that can cause erroneous SMART trips.\nFix an issue that can cause format corrupt.\nFix issues to ensure background scans are performed as scheduled.\nFix an issue that can cause hardware error being reported erroneously.\nFix an issue where Persistent Reservation does not persist on FW download.\nFix an issue that can cause Aborted Command error after a power cycle.\nFix an issue that can cause the drive's not being detected by the host after hot plug.\nFix an issue that can cause IOEDC error then assert.\nFix an issue that can cause IOEDC error.\nFix issues that can cause command timeout.\nFix issues that can cause assert.\nFix issues that can cause drive hang condition.\nEnhancements:\nImprove error logging / reporting accuracy.\nImprove performance for certain workloads.\nImprove SAS protocol compliance."
    },
    {
      "id": "dc4d9b31b476ffc086c28441a7060b994ff12bd8c7791266534a46aca19bec06",
      "name": "Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "version": "B02A",
      "release_id": "CPP97",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-12T04:37:43Z",
      "released": "2024-02-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11252185M/1/SAS-Drive_Firmware_CPP97_WN64_B02A_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CPP97",
      "size": 12644544,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "revision_history": "Fixes: \n\nFix1:  \n- A) When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  B) FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.                                                                                                                                                                              \nFix 2:\n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\nFix 3:\n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "0f2aad04e3d715fe60af5cb8dca609f6a76e3d07ca5f0ab96be68d1f12b515a0",
      "name": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "version": "B326",
      "release_id": "7FV43",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T11:30:04Z",
      "released": "2024-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11166204M/1/SAS-Drive_Firmware_7FV43_WN64_B326_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7FV43",
      "size": 12699824,
      "reboot_required": false,
      "description": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "revision_history": "Fixes: \n\nFix1:  \n- When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  Fixed FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.\n                                                                                                                                                                                   \nFix 2: \n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\n\nFix 3: \n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "261ba63129d1f41b2914071e82cd4a6a82940967e80d3d8e61f5f08155c4a3a8",
      "name": "HGST LS21 for model number(s) HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.",
      "version": "LS21",
      "release_id": "MGW91",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:28Z",
      "released": "2021-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07861414M/2/SAS-Drive_Firmware_MGW91_WN64_LS21_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MGW91",
      "size": 12336240,
      "reboot_required": false,
      "description": "This release contains firmware version LS21 for HGST drives. Vendor model numbers HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "5e79a0ae39f437434e9bd58784c7071caaee4797b0d14a175c5a54b2c9ca82d3",
      "name": "Seagate KT3C for model number(s) ST900MP0026, ST600MP0036 and ST300MP0026",
      "version": "KT3C",
      "release_id": "JMP8Y",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:11Z",
      "released": "2023-08-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10267689M/2/SAS-Drive_Firmware_JMP8Y_WN64_KT3C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JMP8Y",
      "size": 12327328,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Kestrel 512n ISE.  Model Numbers ST900MP0026, ST600MP0036, ST300MP0026.\nFix FW to address drive not ready and self test issues.",
      "revision_history": "- Fix for potential drive-not-ready during boot up.\n- Fix for drive reporting incorrect progress on extended background self test."
    },
    {
      "id": "c3fa3bfa4a100d08fcfd210bbb17970e2f94364f62672e9c9ed24ddf6eba2cee",
      "name": "Seagate KSCC for model number(s) ST900MP0126",
      "version": "KSCC",
      "release_id": "MG6NK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:04:43Z",
      "released": "2023-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09833994M/2/SAS-Drive_Firmware_MG6NK_WN64_KSCC_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MG6NK",
      "size": 12280816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Kestrel 512n FIPS. Model Number ST900MP0126.\nFix FW to address drive not ready and self test issues.",
      "revision_history": "- Fix for potential drive-not-ready during boot up.\n- Fix for drive reporting incorrect progress on extended background self test."
    },
    {
      "id": "7befc05c945f5c3f654ebd22984277341f826f5c59d0f9290977ad0b4488cfa7",
      "name": "Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "version": "EK06",
      "release_id": "GTG81",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-17T06:10:13Z",
      "released": "2024-01-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11140543M/1/SAS-Drive_Firmware_GTG81_WN64_EK06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GTG81",
      "size": 12131264,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "revision_history": "Fixes:\n- Addresses an issue that could cause occasional read errors"
    },
    {
      "id": "5d8c2335761f5dc729d22a939ccc164e23f6c99632d2615b1482961702fec308",
      "name": "HGST KU45  for model number(s) HUS726020ALS210 and HUS726040ALS210.",
      "version": "KU45",
      "release_id": "68X4C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T17:03:19Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150772M/2/SAS-Drive_Firmware_68X4C_WN64_KU45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=68X4C",
      "size": 11746544,
      "reboot_required": false,
      "description": "This release contains firmware version KU45  for HGST drives. Vendor model numbers HUS726020ALS210 and HUS726040ALS210.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "5ea8c7f795f37f1474f7bde4e7761aa8d1ed11e034fc56a893a5ddbc7d9bc272",
      "name": "EH0D for MG06 model number(s) MG06SCA600EY, MG06SCA800EY, MG06SCA10TEY, MG06SCA10TAY, MG06SCA600AY and MG06SCA800AY",
      "version": "EH0D",
      "release_id": "4G5GY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:59:38Z",
      "released": "2022-03-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08099094M/2/SAS-Drive_Firmware_4G5GY_WN64_EH0D_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4G5GY",
      "size": 11610000,
      "reboot_required": false,
      "description": "This release contains firmware version EH0D for MG06 model number(s) MG06SCA600EY, MG06SCA800EY, MG06SCA10TEY, MG06SCA10TAY, MG06SCA600AY and MG06SCA800AY.",
      "revision_history": "Fixes:\n- Fix an issue where an unexpected power loss can cause unrecoverable read error on the following power up."
    },
    {
      "id": "bb82cbf99973004ad4fa46b9d064ac1b23ea7e421990eef9b1994703259e53e1",
      "name": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095",
      "version": "CPE9",
      "release_id": "RRWVT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:56:16Z",
      "released": "2023-09-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10235085M/2/SAS-Drive_Firmware_RRWVT_WN64_CPE9_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RRWVT",
      "size": 12063856,
      "reboot_required": false,
      "description": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095,XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n- Fix drive detection issue.\n\nEnhancements:\n- Enable new DPN for 7.68TB capacity."
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "1422bba58673005e0d8a1f7d9ee1c898c81706f760e54c181b8a463dce6c5e22",
      "name": "Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "version": "BJ07",
      "release_id": "5WMK8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:21:19Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933394M/1/SAS-Drive_Firmware_5WMK8_WN64_BJ07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5WMK8",
      "size": 12038824,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "1fcbe2f15884130068fe5c7cc25584671e6f7044a740a7c5c0d2a66c178bbb28",
      "name": "Kioxia BH07 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "version": "BH07",
      "release_id": "38PHF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:00:20Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933350M/1/SAS-Drive_Firmware_38PHF_WN64_BH07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=38PHF",
      "size": 11958960,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BH07 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "d3eed91a60fa56f5c019a5054397909a6048bc64dd5e68a6554bf7f7f7b8b5de",
      "name": "This release contains firmware version CSNE for STX drives. Vendor model numbers ST8000NM015A.",
      "version": "CSNE",
      "release_id": "YRJ44",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-06T14:30:56Z",
      "released": "2023-09-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10568714M/1/SAS-Drive_Firmware_YRJ44_WN64_CSNE_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YRJ44",
      "size": 12803248,
      "reboot_required": false,
      "description": "This release contains firmware version CSNE for STX drives. Vendor model numbers ST8000NM015A.",
      "revision_history": "Fixes:\n- Fix for potential drive assert during read on arrival.\n- Fix for drive hang after power cycle during cross-download testing."
    },
    {
      "id": "8a73de73c8c6b5f1e8e66d8a45ff10d0799e5aaff58c8774895734ddf8931696",
      "name": "Seagate PSE7 for model number ST8000NM0135.",
      "version": "PSE7",
      "release_id": "TH3C3",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-08-30T10:00:44Z",
      "released": "2023-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10543080M/1/SAS-Drive_Firmware_TH3C3_WN64_PSE7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TH3C3",
      "size": 12350336,
      "reboot_required": false,
      "description": "This release contains firmware version PSE7 for supplier model number ST8000NM0135.",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Fix issue where current Mode Page values reverted to Default values after Power Cycle\n-Fix issue where drive reports false tag overlap error 0B/4E/00\n-Fix issues where command timeout can result\n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\n-Fix issues where IOEDC error can result"
    },
    {
      "id": "7f3c1816a8abb0d5de05c5772def174d0e1ae5f6c9c2ad5523fd664903346ed8",
      "name": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "version": "CSJA",
      "release_id": "J12RT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-06-30T05:01:47Z",
      "released": "2023-06-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10268173M/1/SAS-Drive_Firmware_J12RT_WN64_CSJA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J12RT",
      "size": 12687840,
      "reboot_required": false,
      "description": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSJ8."
    },
    {
      "id": "d6784baaf602be53256144a13d13ccebfe0dd5110a4cb33a3573fb5e5f7f467f",
      "name": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "version": "CPE6",
      "release_id": "2PY92",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-12-14T07:32:22Z",
      "released": "2022-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09346116M/1/SAS-Drive_Firmware_2PY92_WN64_CPE6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2PY92",
      "size": 12209992,
      "reboot_required": false,
      "description": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n-Initial Release"
    },
    {
      "id": "27ea407c83dc92f02b1d6fd8458331571b111a4b1b8b129f7c9a8b86e7c4f1ef",
      "name": "Toshiba EJ09 for MG08 model number(s) MG08SCA16TEY",
      "version": "EJ09",
      "release_id": "9N3RR",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-08-18T08:52:06Z",
      "released": "2022-08-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08893938M/1/SAS-Drive_Firmware_9N3RR_WN64_EJ09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9N3RR",
      "size": 12479016,
      "reboot_required": false,
      "description": "This release contains firmware version EJ09 for MG08 model number(s) MG08SCA16TEY.",
      "revision_history": "Fixes:-\nAddresses an issue that could cause occasional read errors"
    },
    {
      "id": "6b01a365cd3ec211f0220c2550d15f29848832f62579e2e64a7467874c94f2fa",
      "name": "Seagate 4D0C for model number(s) XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "version": "4D0C",
      "release_id": "NX13G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-04-28T10:32:00Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486562M/1/SAS-Drive_Firmware_NX13G_WN64_4D0C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NX13G",
      "size": 11833104,
      "reboot_required": false,
      "description": "This release contains firmware version 4D0C for Seagate drives. Vendor model numbers XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "revision_history": "Fixes:\nFix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can return corrupt data after a power cycle in a corner case.\nFix an issue that can return the sense code 09/80/00 to a WRITE command.\nFix issues that can cause command timeout.\nFix issues that can cause drive assert.\nFix issues that can cause drive hang condition.\nFix an issue that can cause drive-not-ready.\nEnhancements:\nImprove protocol spec compliance.\nImprove throughput performance for specific workloads.\nImprove error logging/sense data reporting."
    },
    {
      "id": "48fc6769c3d54386e4ab4b5c8a174f54b6143834b0cce7bd522820544b4c85a0",
      "name": "This release contains firmware version CSDA for STX drives. Vendor model numbers ST4000NM015A.",
      "version": "CSDA",
      "release_id": "59M5K",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-04-28T09:34:25Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486319M/1/SAS-Drive_Firmware_59M5K_WN64_CSDA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=59M5K",
      "size": 12285536,
      "reboot_required": false,
      "description": "This release contains firmware version CSDA for STX drives. Vendor model numbers ST4000NM015A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSD8.\n\nEnhancements:\nFixes and enhancement included are identical to those of CSD8."
    },
    {
      "id": "2ea2748e5a817413862cea6456c7c329059a045806cd1465168a7274a04871f0",
      "name": "Seagate PT55 for model number(s) ST8000NM0185.",
      "version": "PT55",
      "release_id": "6421F",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-12-15T06:15:22Z",
      "released": "2021-12-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08018016M/1/SAS-Drive_Firmware_6421F_WN64_PT55_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6421F",
      "size": 10934392,
      "reboot_required": false,
      "description": "This release contains firmware version PT55 for supplier model number ST8000NM0185.",
      "revision_history": "Fixes:\n- Fix an issue that can make the drive unresponsive following a Hard Reset during writes.\n- Fix issues that can cause command timeout.\n- Fix issues that can cause Assert condition.\n- Fix an issue that can cause IOEDC error.\n\nEnhancements:\n- Improve performance for certain workloads.\n- Improve error logging / sense code reporting accuracy.\n- Improve SAS spec compliance."
    },
    {
      "id": "28b7430872397bcaa308f9ad1dfda5fee488eb3d6bea07fdac333a7b8687c70c",
      "name": "Seagate RSL5 for model number(s) ST10000NM0598, ST12000NM0158 and ST14000NM0168.",
      "version": "RSL5",
      "release_id": "VTX9C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-11-16T03:10:49Z",
      "released": "2021-11-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07925738M/1/SAS-Drive_Firmware_VTX9C_WN64_RSL5_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VTX9C",
      "size": 11410424,
      "reboot_required": false,
      "description": "This release contains firmware version RSL5 for Seagate drives. Vendor model numbers ST10000NM0598, ST12000NM0158 and ST14000NM0168.",
      "revision_history": "Fixes:\nFix issues that can cause IOEDC errors.\n\nEnhancements:\nEnhance sense code reporting accuracy\nIncreased BMS interval timer value"
    },
    {
      "id": "afad81c11ff922969d371d0fc4f99acfa5bc2d5a7b4cd74e2d2c1481ff5f57eb",
      "name": "Seagate KT5C for model number(s) DL900MP0136.",
      "version": "KT5C",
      "release_id": "83FF4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-08-27T08:44:48Z",
      "released": "2021-08-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07688573M/1/SAS-Drive_Firmware_83FF4_WN64_KT5C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=83FF4",
      "size": 11012312,
      "reboot_required": false,
      "description": "This release contains firmware version KT5C for Seagate drives. Vendor model numbers DL900MP0136.",
      "revision_history": "Fixes:\nFix an issue where single SAS port becomes unresponsive\nFix issues that can cause unwarranted SMART warning\nFix issues where assert can result\nFix issues where drive hang condition can result\nFix issues where command timeout can result\nEnhancements:\nImprove performance for certain workloads\nEnhance error logging / sense code reporting accuracy"
    },
    {
      "id": "edef243d8108958192caa385e61442f4dfeee160057a70aae31d7de1ea520510",
      "name": "Seagate KT7B for model number(s) ST900MP0136..",
      "version": "KT7B",
      "release_id": "0V8XY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-08-27T08:28:32Z",
      "released": "2021-08-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07688491M/1/SAS-Drive_Firmware_0V8XY_WN64_KT7B_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0V8XY",
      "size": 11012712,
      "reboot_required": false,
      "description": "This release contains firmware version KT7B for Seagate drives. Vendor model numbers ST900MP0136..",
      "revision_history": "Fixes:\nFix an issue where single SAS port becomes unresponsive\nFix issues that can cause unwarranted SMART warning\nFix issues where assert can result\nFix issues where drive hang condition can result\nFix issues where command timeout can result\nEnhancements:\nImprove performance for certain workloads\nEnhance error logging / sense code reporting accuracy"
    },
    {
      "id": "9f54d16b6a912067843cc2bd8568d7b9c3911cac62f7725298299613a5828fca",
      "name": "Seagate Lange Firmware Version EC16  for model number(s) XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "version": "EC16",
      "release_id": "H3VHX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-02-04T09:29:43Z",
      "released": "2021-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07035193M/1/SAS-Drive_Firmware_H3VHX_WN64_EC16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3VHX",
      "size": 10683112,
      "reboot_required": false,
      "description": "This release contains firmware version EC16 for Seagate drives. Vendor model numbers XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "revision_history": "Fixes:\n-Fix an issue where reading or writing of corrupt data can result after a power cycle\n-Fix an issue which can lead to reduced data retention duration\n-Fix an issue where assert can result when max. queue depth is exceeded\n-Update activity LED blinking behavior to be consistent with Dell requirements\n\nEnhancements:\n-N/A"
    },
    {
      "id": "c5588391f0a03e3164e65420df8fd4c986d5e2e0e1ac057b400ce83fe8e96914",
      "name": "WESTERN DIGITAL SAS12 WUS721010AL4200 and WUS721010AL5200 for FW TS03",
      "version": "TS03",
      "release_id": "YY7FX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-06-08T06:07:54Z",
      "released": "2020-06-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06306475M/1/SAS-Drive_Firmware_YY7FX_WN64_TS03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YY7FX",
      "size": 11411024,
      "reboot_required": false,
      "description": "This release contains firmware version TS03 for Western Digital Hard Drive. Vendor model number WUS721010AL5200 and WUS721010AL4200",
      "revision_history": "Fixes:\n- FW release includes fix for SCT Timeouts caused by interaction between internal cache command and read stream.\n- FW also address underlying issues that may lead to flash header corruption.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "629d5fb27f74f6eb49ee0f4138a473929570edcca75b5a873ae5090655987a4a",
      "name": "Toshiba EA05 for model number(s) AL14SEB030NY, AL14SEB060NY and AL14SEB120NY.",
      "version": "EA05",
      "release_id": "TGCJ8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-03-27T11:21:24Z",
      "released": "2020-03-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06178570M/1/SAS-Drive_Firmware_TGCJ8_WN64_EA05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TGCJ8",
      "size": 10476472,
      "reboot_required": false,
      "description": "This release contains firmware version EA05 for Toshiba drives. Vendor model numbers AL14SEB030NY, AL14SEB060NY and AL14SEB120NY.",
      "revision_history": "Fixes:\n- Invalid DWORD during Link Reset\n- Apply the Pin11 Specification rev A03\n- 04-4C-91 when drive executes internal reboot\n- Self reboot when 8 commands terminated for TASK SET FULL\n- HDD reports sense 02-04-11 on NOTIFY (Enable Spin Up)\n- Write splice may occur on power loss during ATI\n- HDD hang under specific conditions when Task Set Full\n- HDD hang under specific conditions when TB=1\n- Soft errors in SoC memory\n- Power loss during self test \n- Duplicate sense code sent\n- HDD may hang on hard reset\n\nEnhancements:\n N/A"
    },
    {
      "id": "9cb177ff68cdcacaea5c2e503623fd7a714f7fb1636ab3be4d51aa44fba3c959",
      "name": "Toshiba EB04 for model number(s) AL14SEB18EQY.",
      "version": "EB04",
      "release_id": "NYK8R",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-02-05T05:29:40Z",
      "released": "2020-02-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06078016M/1/SAS-Drive_Firmware_NYK8R_WN64_EB04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NYK8R",
      "size": 10660512,
      "reboot_required": false,
      "description": "This release contains firmware version EB04 for Toshiba drives. Vendor model numbers AL14SEB18EQY..",
      "revision_history": "DOW weight increased to improve protection against signal degradation by ATI"
    },
    {
      "id": "aa21bafc81cea64e80e431bf2d1e8530104677e6fd1258c71103fa959e41c19e",
      "name": "Seagate TT56 for model number(s) ST10000NM0256.",
      "version": "TT56",
      "release_id": "CD2WP",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-12-17T09:57:44Z",
      "released": "2019-12-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06001086M/1/SAS-Drive_Firmware_CD2WP_WN64_TT56_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CD2WP",
      "size": 10932728,
      "reboot_required": false,
      "description": "This release contains firmware version TT56 for Seagate Tatsu drives - Vendor model number ST10000NM0256.",
      "revision_history": "Fixes: \n-Fix issues where command timeout can result\n-Fix an issue where assert condition can result\n-Fix minor bugs\n\nEnhancements:\n-Improve performance for specific workloads\n-Improve interface protocol compliance"
    },
    {
      "id": "d70e124fd5eb47e2c840087efbaab515361bdd2d7a22418a95246960b9800a43",
      "name": "Samsung DSL8 for model number(s) MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "version": "DSL8",
      "release_id": "PN27G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T20:14:23Z",
      "released": "2018-05-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04994832M/2/SAS-Drive_Firmware_PN27G_WN64_DSL8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PN27G",
      "size": 10407664,
      "reboot_required": false,
      "description": "This release contains firmware version DSL8 for Samsung drives. Vendor model numbers MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "revision_history": "Fixes\n-n/a\n\nEnhancements\n-n/a"
    },
    {
      "id": "c167a624468a834e419f2e7acf82c5cc2654cbe751c39da1c3c9ecfb54e0cfaa",
      "name": "Seagate NT72 for model number(s) ST2000NX0373.",
      "version": "NT72",
      "release_id": "WN08D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T19:37:16Z",
      "released": "2018-12-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05384185M/4/SAS-Drive_Firmware_WN08D_WN64_NT72_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WN08D",
      "size": 10530576,
      "reboot_required": false,
      "description": "This release contains firmware version NT72 for SUPPLIER model number(s) ST2000NX0373  Capacity of 2TB.",
      "revision_history": "fixes:\n-improve compatibility with Linux OS after Sanitize Cryptographic Erase was performed\n-Fix issues where Command Timeout can result\n-Fix issues where Assert can result\n-Fix an issue where drive hang can result\n-Fix an issue where Current Mode Page values revert to Default values after power cycle\n\nenhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "ca447b7cbe92d8e56fd4a0883ef22094fc92b85e6467adee95c00d485898fed4",
      "name": "Seagate PT74 for model number(s) ST8000NM0195..",
      "version": "PT74",
      "release_id": "WKRV9",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-08-15T05:42:56Z",
      "released": "2019-08-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05786575M/1/SAS-Drive_Firmware_WKRV9_WN64_PT74_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WKRV9",
      "size": 10865464,
      "reboot_required": false,
      "description": "This release contains firmware version PT74 for Seagate drives. Vendor model numbers ST8000NM0195..",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Fix issue where current Mode Page values reverted to Default values after Power Cycle\n-Fix issue where drive reports false tag overlap error 0B/4E/00\n-Fix issues where command timeout can result\n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "cf04369966eaf08ab986b13a85a2a7f2d0e058daf148bc011cde7d720abc1576",
      "name": "Seagate DSF3 for model number(s) ST4000NM0135..",
      "version": "DSF3",
      "release_id": "5M6GD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-07-26T06:17:17Z",
      "released": "2019-07-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05754416M/1/SAS-Drive_Firmware_5M6GD_WN64_DSF3_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5M6GD",
      "size": 10777472,
      "reboot_required": false,
      "description": "This release contains firmware version DSF2 for Seagate drives. Vendor model numbers ST4000NM0135..",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Fix issue where current Mode Page values reverted to Default values after Power Cycle\n-Fix issue where drive reports false tag overlap error 0B/4E/00\n-Fix issues where command timeout can result\n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "f19d623d58cb895d7e732c106ae92206f7be233121ece9c89dedba6cc95d576d",
      "name": "Seagate DT32 for model number(s) ST4000NM0295, ST2000NM0155 and ST1000NM0085.",
      "version": "DT32",
      "release_id": "3CRY1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-02-15T06:34:06Z",
      "released": "2019-01-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05461185M/1/SAS-Drive_Firmware_3CRY1_WN64_DT32_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3CRY1",
      "size": 10756320,
      "reboot_required": false,
      "description": "This release contains firmware version DT31 for Seagate drives. Vendor model numbers ST4000NM0295, ST2000NM0155 and ST1000NM0085.",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Fix issue where current Mode Page values reverted to Default values after Power Cycle    \n-Fix issue where drive reports false tag overlap error 0B/4E/00\n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\n-Fix issues where command timeout can result\n\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "06e6fa1d3e0650bdf356b4d03849c30c13263e8e3565403075dfdeb7a65f1a3e",
      "name": "Seagate BS05 for HDD ON 2.5 SAS12 15K 512e drive model number ST600MM0238 and ST300MM0078.",
      "version": "BS05",
      "release_id": "2R4CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-02-15T05:59:39Z",
      "released": "2019-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05461025M/1/SAS-Drive_Firmware_2R4CX_WN64_BS05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2R4CX",
      "size": 10737736,
      "reboot_required": false,
      "description": "This release contains firmware version BS05 for Seagate HDD Thunderbug 2.5 SAS12 10K 512n drive. Vendor model numbers: ST600MM0238 and ST300MM0078",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Current Mode Page values reverted to Default values after Power Cycle     \n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\n-Fix issues where command timeout can result\n-Fix issues where IOEDC error can result\n\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "10491b1c00614db7fd96d7c1826dad32e8959d9543522c1cd493d78408ab81f1",
      "name": "This release contains firmware version DS44 for Seagate drives. Vendor model numbers ST6000NM0105.",
      "version": "DS44",
      "release_id": "N04WN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-02-15T03:16:34Z",
      "released": "2019-02-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05460604M/1/SAS-Drive_Firmware_N04WN_WN64_DS44_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N04WN",
      "size": 10822936,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also reduces occasional long command completion latency. This release contains firmware version DS44 for Seagate drives. Vendor model numbers ST6000NM0105..",
      "revision_history": "Fixes:\n-none\n\nEnhancements:\n-Enabled firmware download by Microsoft Windows Server OS"
    },
    {
      "id": "2b640a1d6164bd5474c4daf2317c4d1e2048836e0608b4b0a3b0caa51e708a90",
      "name": "Seagate NT32 for model number(s) ST2000NX0463 and ST1000NX0473.",
      "version": "NT32",
      "release_id": "GW3V7",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T09:37:37Z",
      "released": "2018-08-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05151883M/2/SAS-Drive_Firmware_GW3V7_WN64_NT32_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GW3V7",
      "size": 10436112,
      "reboot_required": false,
      "description": "This release contains firmware version NT31 for Seagate drives. Vendor model numbers ST2000NX0463 and ST1000NX0473.",
      "revision_history": "Fixes\n- Enable Cache Management Resource Overflow Prevention to resolve command timout\n- Current Mode Page values reverted to Default values after Power Cycle\n- Drive fails to protect the sector if EPOW arrives during write retries\n- Command timeouts after Sanitize Command is executed\n- DEFT fails segment unexpectedly when interrupted\n- Drive Self-Test Read Scan Stuck\n- Pad LOD Files To 4K Boundary for Dell SAS\n- Unexpected power mode transition during Background Extended DST causing assert\n- Assert after Task Management Function aborted by Hard Reset\n- Various asserts reported during Active Immediate command\n- Modify Sanitize Crypto Erase behavior to write zeros to OD and ID\n- Turn on the PS bit for mode page 19 subpages\n- Assert on Sequential Write When First Write is Sending Status\n- Enable Support for Active DIC feature on DELL MC and BC configurations\n- Update DST subtest to improve handling of commands that interrupt DST.\n- Drive reported false tag overlap error 0B/4E/00/01\n- Drive did not reject Default DST command while DEFT in progress\n- Drive Assert during Band Delete/Create with concurrent I/O\n- Data abort on channel hardware access after PLL loss-of-lock\n\nEnhancements\nn/a"
    },
    {
      "id": "f49726ba768d5d95b721f736aaafd02baf4adad22a0ee2d5cec7de1ae8665a32",
      "name": "Seagate TSC9 for model number(s) ST1200MM0108..",
      "version": "TSC9",
      "release_id": "8RN2D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T08:09:35Z",
      "released": "2018-01-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04756109M/2/SAS-Drive_Firmware_8RN2D_WN64_TSC9_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8RN2D",
      "size": 10483456,
      "reboot_required": false,
      "description": "This release contains firmware version TSC9 for Seagate drives. Vendor model numbers ST1200MM0108..",
      "revision_history": "Fixes:\n'-Fix an issue where access to drive is erroneously denied during drive self test\n-Fix an issue where Offline Extended DST is reported in progress status indefinitely\n-Fix issues where assert condition can result\n-Fix issues where command timeout can result\n-Fix an issue where incorrect value can be reported in Saved Mode Pages\n\nEnhancements:\n- N/A"
    },
    {
      "id": "ea33e301f0bccfa657de7fc2030c09c0ca79f634d22a285a5d06df1d6fd6df8c",
      "name": "Toshiba AS0E for model number(s) PX05SMB320Y, PX05SMB160Y, PX05SMB080Y, PX05SMB040Y, PX05SVB384Y, PX05SVB192Y, PX05SVB096Y, PX05SVB048Y, PX05SRB384Y, PX05SRB192Y, PX05SRB096Y and PX05SRB048Y.",
      "version": "AS0E",
      "release_id": "0G2TK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T04:16:29Z",
      "released": "2018-08-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05153780M/3/SAS-Drive_Firmware_0G2TK_WN64_AS0E_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0G2TK",
      "size": 10600424,
      "reboot_required": false,
      "description": "This release contains firmware version AS0E for Toshiba drives. Vendor model numbers PX05SMB320Y, PX05SMB160Y, PX05SMB080Y, PX05SMB040Y, PX05SVB384Y, PX05SVB192Y, PX05SVB096Y, PX05SVB048Y, PX05SRB384Y, PX05SRB192Y, PX05SRB096Y and PX05SRB048Y.",
      "revision_history": "Fixes\nn/a\n\nEnhancements\nn/a"
    },
    {
      "id": "4695419d23bdd78166088b177010e8fe91d8488323b8fe526201c4f263dd0af5",
      "name": "Toshiba EC02 for model number(s) AL13SXB30ENY and AL13SXB60ENY.",
      "version": "EC02",
      "release_id": "47FXP",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-27T18:19:16Z",
      "released": "2017-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04337050M/3/SAS-Drive_Firmware_47FXP_WN64_EC02_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=47FXP",
      "size": 9662008,
      "reboot_required": false,
      "description": "This release contains firmware version EC02 for Toshiba drives. Vendor model numbers AL13SXB30ENY and AL13SXB60ENY.",
      "revision_history": "Fixes:\n-Firmware fix for TASK SET FULL bug during multiport usage.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "04ec308a99971de5cff5f462337b720c363907e5555189bb9cfd4a864710fd66",
      "name": "Seagate NSF2 for model number(s) ST2000NX0453..",
      "version": "NSF2",
      "release_id": "1HWVN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-21T08:24:58Z",
      "released": "2019-01-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05424349M/1/SAS-Drive_Firmware_1HWVN_WN64_NSF2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1HWVN",
      "size": 10649408,
      "reboot_required": false,
      "description": "This release contains firmware version NSF2 for Seagate drives. Vendor model numbers ST2000NX0453..",
      "revision_history": "Fixes\n-improve compatibility with Linux OS after Sanitize Cryptographic Erase was performed\n-Fix issues where Command Timeout can result\n-Fix issues where Assert can result\n-Fix an issue where drive hang can result\n-Fix an issue where IOEDC error can result\n-Fix an issue where Current Mode Page values revert to Default values after power cycle\n\nEnhancements\n-Improve performance for specific workload cases\n-Improve status/reporting accuracy"
    },
    {
      "id": "4fbfe9a6dad569fce77de63403d506f7eadd69d383980ede0b527ff7b27c4f17",
      "name": "Seagate 2T51 for model number(s) ST1800MM0198..",
      "version": "2T51",
      "release_id": "5YH6J",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-02-17T21:55:39Z",
      "released": "2017-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04190540M/1/SAS-Drive_Firmware_5YH6J_WN64_2T51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5YH6J",
      "size": 17138992,
      "reboot_required": false,
      "description": "This release contains firmware version 2T51 for Seagate drives. Vendor model numbers ST1800MM0198..",
      "revision_history": "Initial release"
    },
    {
      "id": "a4a85d64c2a0d119932848e41a3b06019d8b8062c1169f30f894f9b6d78a5cdf",
      "name": "Seagate UT71 for model number(s) ST1200MM0198..",
      "version": "UT71",
      "release_id": "W7K02",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-02-17T21:25:50Z",
      "released": "2017-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04190452M/1/SAS-Drive_Firmware_W7K02_WN64_UT71_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=W7K02",
      "size": 17010400,
      "reboot_required": false,
      "description": "This release contains firmware version UT71 for Seagate drives. Vendor model numbers ST1200MM0198..",
      "revision_history": "Initial release"
    }
  ]
}