{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "r260",
  "name": "R260",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge R260 SAS Drive Updates",
  "filter": "sas-drive",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 23,
      "rss": "/r260/urgent/rss.xml",
      "api": "/api/r260/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 77,
      "rss": "/r260/recommended/rss.xml",
      "api": "/api/r260/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 31,
      "rss": "/r260/optional/rss.xml",
      "api": "/api/r260/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/r260/bios/rss.xml",
      "api": "/api/r260/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/r260/boss/rss.xml",
      "api": "/api/r260/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/r260/chipset/rss.xml",
      "api": "/api/r260/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/r260/diagnostics/rss.xml",
      "api": "/api/r260/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/r260/drivers-for-os-deployment/rss.xml",
      "api": "/api/r260/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 15,
      "rss": "/r260/express-flash-pcie-ssd/rss.xml",
      "api": "/api/r260/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/r260/firmware/rss.xml",
      "api": "/api/r260/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/r260/idrac/rss.xml",
      "api": "/api/r260/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 16,
      "rss": "/r260/network/rss.xml",
      "api": "/api/r260/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 37,
      "rss": "/r260/sas-drive/rss.xml",
      "api": "/api/r260/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 9,
      "rss": "/r260/sas-non-raid/rss.xml",
      "api": "/api/r260/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 12,
      "rss": "/r260/sas-raid/rss.xml",
      "api": "/api/r260/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/r260/security/rss.xml",
      "api": "/api/r260/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 31,
      "rss": "/r260/serial-ata/rss.xml",
      "api": "/api/r260/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/r260/systems-management/rss.xml",
      "api": "/api/r260/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/r260/video/rss.xml",
      "api": "/api/r260/video"
    }
  ],
  "count": 37,
  "updates": [
    {
      "id": "14646318eed9bac1cd8e2b6564c5b3f136a7e60b8437700c0a1d1dfa05775f75",
      "name": "Firmware update for WDC Paris-CP SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200",
      "version": "AS06",
      "release_id": "XTC10",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T06:13:54Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14472580M/1/SAS-Drive_Firmware_XTC10_WN64_AS06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XTC10",
      "size": 22713344,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP  AS06 FW SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200.",
      "revision_history": "- Firmware update to ensure the 512e Dell Model string and Dell Device ID will not show correctly when Server code is loaded over Storage code.\n- FW fix to ensure Background Media Scan timer is reset correctly when Offline Data Collection is started.\n- Code updated to ensure Component ID and Model string will report correctly after firmware upload."
    },
    {
      "id": "c73beccb3d67ad1b365735cea9aefae76310134df79570616d77bd8f290f431d",
      "name": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205",
      "version": "AM05",
      "release_id": "HTW37",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T10:16:13Z",
      "released": "2025-11-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13893761M/1/SAS-Drive_Firmware_HTW37_WN64_AM05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HTW37",
      "size": 25081440,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205.\nCode updated to fix potential issue during Dell Factory Test.",
      "revision_history": "Firmware update to address potential issue during Dell Enhanced Factory Test."
    },
    {
      "id": "b9c46d96040d3002cf5c44f7e7ab2a9b4fa8590564eb834f2797f02925f4e35a",
      "name": "FW update for of Toshiba MG09 SAS ISE.  Model numbers MG09SCA18TEY, MG09SCA16TEY, and MG09SCA12TEY",
      "version": "EM06",
      "release_id": "20Y02",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-10-21T05:49:55Z",
      "released": "2025-10-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13764807M/1/SAS-Drive_Firmware_20Y02_WN64_EM06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=20Y02",
      "size": 23534880,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG09 SAS ISE.  Model numbers MG09SCA18TEY, MG09SCA16TEY, and MG09SCA12TEY.\nFix for a Background Medium Scan issue and potential timeout.",
      "revision_history": "- Fixed a problem during Background Medium Scan or Drive Self-test in which a long read with command interrupt disabled was performed under certain conditions and other commands could not be executed.\n- Fixed the issue that could cause a SCT timeout response to fail after Flush Cache Command.\n- Fixed the issue that write commands are abnormally executed two times internally and cause BCRC error or SATA I/F protocol error."
    },
    {
      "id": "b0662e0dcea48ec11fc02672748c18c4038ef58e28c60e92dd1cc21b8f8d6bde",
      "name": "Toshiba MG08SD SAS ISE drive program for EL02 FW for model number(s): MG08SDA800EY",
      "version": "EL02",
      "release_id": "F95CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-09-03T09:09:09Z",
      "released": "2025-09-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13580189M/1/SAS-Drive_Firmware_F95CX_WN64_EL02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F95CX",
      "size": 23279080,
      "reboot_required": false,
      "description": "FW update for of  Toshiba MG08SD SAS ISE.  Model number MG08SDA800EY.\nFix for a Background Medium Scan issue and potential timeout.",
      "revision_history": "- Fixed a problem during Background Medium Scan or Drive Self-test in which a long read with command interrupt disabled was performed under certain conditions and other commands could not be executed.\n - Fixed the issue that could cause a SCT timeout response to fail after Flush Cache Command.\n - Fixed the issue that write commands are abnormally executed two times internally and cause BCRC error or SATA I/F protocol error."
    },
    {
      "id": "41d8ddf307b4ef32924e88af9618acf8165484bb258955e0c6381fffd74cec21",
      "name": "Seagate SBTA for Skybolt ServoBP program for model number(s) CL2400MM0149",
      "version": "SBTA",
      "release_id": "HH6J1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:02:18Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12677112M/2/SAS-Drive_Firmware_HH6J1_WN64_SBTA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HH6J1",
      "size": 23874432,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512n ISE. Model Number CL2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "4c6ed6166ab2e1a3e699af648e5457cd81edd18f87e2beea7561f7262fa1fa6d",
      "name": "Seagate SBSA for Skybolt ServoBP program for model number(s) BL2400MM0159",
      "version": "SBSA",
      "release_id": "00P56",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:22:58Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676520M/2/SAS-Drive_Firmware_00P56_WN64_SBSA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=00P56",
      "size": 23874416,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512e ISE.  Model Number BL2400MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "488b6d18b0e0ce3ac333ac5692fdf90c286b1f6fbbc6ac6a30f8212c5813f8ad",
      "name": "Firmware Update for EvansBP SAS ISE HDD. Model numbers: ST12000NM006J, ST14000NM006J, ST16000NM006J, ST18000NM006J",
      "version": "PSLG",
      "release_id": "XF65R",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:36:19Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12783645M/2/SAS-Drive_Firmware_XF65R_WN64_PSLG_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XF65R",
      "size": 23710648,
      "reboot_required": false,
      "description": "This release contains firmware version PSLG for Seagate drives. Vendor model numbers ST12000NM006J, ST14000NM006J, ST16000NM006J, ST18000NM006J.\nFirmware changes include fixes for early heat application from Idle sweep seek and potential assert during write uncorrectable testing.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential assert during Write Uncorrectable testing\n- Shorten time delay before running Direct Offline Scan"
    },
    {
      "id": "0c35e7ef25c69e2ab6c9f4c82eb0b9bba7107da2d604217f9dcd9d9848a86e2a",
      "name": "Seagate CimarronBP SAS ISE for FW LS0E for model numbers: ST8000NM024B",
      "version": "LS0E",
      "release_id": "FJ97K",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T06:32:22Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12816090M/2/SAS-Drive_Firmware_FJ97K_WN64_LS0E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FJ97K",
      "size": 24019096,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS ISE 512e HDD.  Model number: ST8000NM024B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "838387e0a28337097a14adabdc9607c0a6286c98d29f50a1e80938cbad0c708e",
      "name": "WDC Paris-C SAS ISE US09 for model numbers WUH721816AL5200, WUH721818AL5200",
      "version": "US09",
      "release_id": "GY6MD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-07-01T10:59:13Z",
      "released": "2025-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13323594M/1/SAS-Drive_Firmware_GY6MD_WN64_US09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GY6MD",
      "size": 25702128,
      "reboot_required": false,
      "description": "FW update for of  WDC Paris-C SAS ISE.  Model numbers WUH721816AL5200, WUH721818AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optiminum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "56221de0237fbeeb680e5eac2cb8d3e0f72799000d1986cf8fb68d7d02d297cd",
      "name": "Seagate SSEJ for model number(s) ST2400MM0149",
      "version": "SSEJ",
      "release_id": "KHJ9C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:13:51Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676334M/3/SAS-Drive_Firmware_KHJ9C_WN64_SSEJ_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHJ9C",
      "size": 24679816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512n ISE. Model Number ST2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "- Add support for Hynix V8 NAND part."
    },
    {
      "id": "94cddbcf632ba8d62bf8fd89359de9b60c19a24649fa5a370ba55cb90e9ddaad",
      "name": "Seagate CimarronBP SAS for FW LW0B for model numbers ST2000NM013B, ST4000NM019B",
      "version": "LW0B",
      "release_id": "3P5N0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-16T09:10:59Z",
      "released": "2025-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12648511M/2/SAS-Drive_Firmware_3P5N0_WN64_LW0B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3P5N0",
      "size": 24698960,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS ISE 512n HDD.  Model numbers: ST2000NM013B and ST4000NM019B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "c2499ab3befc7f8aac45f1eb2b078813e866b63b701d8296d5628475a85b6e14",
      "name": "HGST NS11 for model number(s) HUH721212AL5200 and HUH721212AL4200",
      "version": "NS11",
      "release_id": "04PM5",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:07:34Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12029572M/2/SAS-Drive_Firmware_04PM5_WN64_NS11_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=04PM5",
      "size": 24602048,
      "reboot_required": false,
      "description": "This release contains firmware version NS11 for HGST drives. Vendor model numbers HUH721212AL5200 and HUH721212AL4200.\nFW update for WDC Leo-A 512e SAS HDD, Model number HUH721212AL5200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes. \n'FW update for WDC Leo-A 4Kn SAS HDD, Model number HUH721212AL4200.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "- Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance"
    },
    {
      "id": "851192910676f62564014c1ffe71bea150f0ccd442fae8c4d0e4d63fda7efb42",
      "name": "Toshiba EF09 for model number(s) AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY",
      "version": "EF09",
      "release_id": "J11N2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T10:54:37Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12128055M/2/SAS-Drive_Firmware_J11N2_WN64_EF09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J11N2",
      "size": 23842608,
      "reboot_required": false,
      "description": "This release contains firmware version EF09 for Toshiba drives. Vendor model numbers AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY.\nRevert high fly write detection methodology back to process used in previous EF06 Firmware",
      "revision_history": "Revert high fly write detection methodology back to process used in previous EF06 Firmware."
    },
    {
      "id": "736e89923bb3c28df28dc52a33909657ef3c7f17816fa6be7cd3ade0082728b9",
      "name": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "version": "C40E",
      "release_id": "57MM2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:28:10Z",
      "released": "2024-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374876M/2/SAS-Drive_Firmware_57MM2_WN64_C40E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=57MM2",
      "size": 24391360,
      "reboot_required": false,
      "description": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "revision_history": "Fixes: \n\n- Fix1: FW is fixed to execute the flush process and Flash Memory parameter modification process exclusively.\n- Fix2: Fixed that the host I/O proceed by the skip of GC if the validity determination process of user data takes time.\n- Fix3: Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "2d586d18bf6bfd668a4b76e782765a56bb78bffe1a219c60613e9b1ae474dbde",
      "name": "Model numbers are KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8, KPM7XRUG960G, KPM7XVUG800G, KPM7XMUG400G, KPM7XMUG800G, KPM7XMUG1T60",
      "version": "C10E",
      "release_id": "T21WT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:11:55Z",
      "released": "2024-06-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374981M/2/SAS-Drive_Firmware_T21WT_WN64_C10E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T21WT",
      "size": 24314272,
      "reboot_required": false,
      "description": "This release contains firmware version C10E for Kioxia PM7 24Gbps SAS 2.5 (10WPD, 1WPD, 3WPD).\nModel numbers are KPM7XMUG400G, KPM7XMUG800G, and KPM7XMUG1T60,\nKPM7XVUG800G, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8,KPM7XRUG960G, KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3.",
      "revision_history": "Fix:\n\n-  Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "0776b5d687d3fbafca1eb2f20fa128d1b4ec7423dcc2fefe3e9f3387ab95092f",
      "name": "Kioxia BA48 FW for PM6 drives for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "version": "BA48",
      "release_id": "NGPR2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T05:55:37Z",
      "released": "2022-09-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08764563M/4/SAS-Drive_Firmware_NGPR2_WN64_BA48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NGPR2",
      "size": 24171504,
      "reboot_required": false,
      "description": "Kioxia PM6 BA48 FW for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "revision_history": "Fixes:\nInitial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "5bdddd1d8557db43989a33ba11ce36bc1dd41874116c02b65d9bb1d605696706",
      "name": "Seagate CimarronBP SAS FIPS for LT0E FW for Model numbers: ST8000NM022B",
      "version": "LT0E",
      "release_id": "4T1MM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-06T06:42:36Z",
      "released": "2025-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12816183M/1/SAS-Drive_Firmware_4T1MM_WN64_LT0E_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4T1MM",
      "size": 24932568,
      "reboot_required": false,
      "description": "Firmware Update for CimarronBP SAS FIPS 512e HDD.  Model number: ST8000NM022B.\nFirmware changes include fixes for early heat application from Idle sweep seek.",
      "revision_history": "- Servo code change to correct the behavior of heat being applied during the seek when Idle sweep seek is interrupted by a write command.\n- Fix for potential drive hang due to head of queue write command miscount.\n- Fix for potential assert during test with injected queue full and IT nexus loss conditions."
    },
    {
      "id": "632cefa984ce903c90ae86afbe7b607b60915f5c751fe564c63e5b134b5be866",
      "name": "HGST NM11 for model number(s) HUH721212AL5205",
      "version": "NM11",
      "release_id": "M6T4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-08-22T15:02:58Z",
      "released": "2024-08-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12015224M/1/SAS-Drive_Firmware_M6T4D_WN64_NM11_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M6T4D",
      "size": 13326064,
      "reboot_required": false,
      "description": "This release contains firmware version NM11 for HGST drives. Vendor model numbers HUH721212AL5205 of capacity 12TB.\n\"FW update for WDC Leo-A 512e SAS FIPS HDD, Model number HUH721212AL5205.\nIncludes FW fixes to implement improved Vertical Write Inhibit feature to better detect poor writes.\"",
      "revision_history": "\"-Implement algorithm to find false VWI (Vertical Write Inhibit) detection and adjust sensor threshold\n- Ensure consistency for hardware state before/after temporary change due to Vertical Write Inhibit Trigger\n- Enable Vertical Write Inhibit feature improvement, by supporting MD and OD expansion\n- Set optimum parameter for Vertical Write Inhibit Feature to maintain drive performance\""
    },
    {
      "id": "a3327e1940b3fe3b81e47fa9d3bb7aeffd6956b5f4ee06f4a9f14c97f3c83a19",
      "name": "Samsung PM1653 drives for DSG9 FW for model numbers MZILG960HCHQAD3, MZILG1T9HCJRAD3, MZILG3T8HCLSAD3, MZILG7T6HBLAAD3 and MZILG15THBLAAD3",
      "version": "DSG9",
      "release_id": "3MV58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T17:20:50Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11939710M/1/SAS-Drive_Firmware_3MV58_WN64_DSG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3MV58",
      "size": 13264392,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count acuracy and drive temperature reporting during format operations. Firmware version DSG9 for Samsung PM1653 drives. Vendor model numbers MZILG960HCHQ-0AD3, MZILG1T9HCJR-0AD3, MZILG3T8HCLS-0AD3, MZILG7T6HBLA-0AD3, and MZILG15THBLA-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "e15c231399536e80009d372366b4e72a4c66dedf951ad1fa78d1309ab3e37961",
      "name": "Samsung PM1655 drives for FW DWG9 for model numbers MZILG800HCHQAD3, MZILG1T6HCJRAD3 and MZILG3T2HCLSAD3",
      "version": "DWG9",
      "release_id": "7MTXM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T08:00:58Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11937657M/1/SAS-Drive_Firmware_7MTXM_WN64_DWG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7MTXM",
      "size": 13261200,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count accuracy and drive temperature reporting during format operations. Firmware version DWG9 for Samsung PM1655 drives. Vendor model numbers MZILG800HCHQ-0AD3, MZILG1T6HCJR-0AD3, and MZILG3T2HCLS-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "13796d98c89ff1cc8cda76d598f7dfe5ccc925a8fadfd3999fb71e9fbcb079fb",
      "name": "WDC Bear Cove Quantum FIPS-140 L138 for 1WPD and 3WPD  model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205,WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "version": "L138",
      "release_id": "16C85",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T05:58:21Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11654668M/1/SAS-Drive_Firmware_16C85_WN64_L138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=16C85",
      "size": 12580296,
      "reboot_required": false,
      "description": "This release contains firmware version L138 for WDC Bear Cove Quantum FIPS-140 1WPD and 3WPD. For model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205, WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "57c906ff5507962cafb5c3c783d13f06921a3b3fc05d0d6ba692520b4090e167",
      "name": "Seagate ST37 for model number(s) ST600MM0069 and ST1200MM0099.",
      "version": "ST37",
      "release_id": "C161G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-29T10:13:00Z",
      "released": "2023-07-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09844732M/3/SAS-Drive_Firmware_C161G_WN64_ST37_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C161G",
      "size": 13245848,
      "reboot_required": false,
      "description": "This release contains firmware version ST36 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error hapepends during a head switch with RAW enabled."
    },
    {
      "id": "9d1c1564008221f1f7a7c85b77df4c49bc728867b7bffb5361e743e9f19ed7b9",
      "name": "Seagate SBW5 for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "version": "SBW5",
      "release_id": "9KWMD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-26T11:29:43Z",
      "released": "2023-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09947108M/2/SAS-Drive_Firmware_9KWMD_WN64_SBW5_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9KWMD",
      "size": 13258560,
      "reboot_required": false,
      "description": "This release contains firmware version SBW5 Seagate for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled."
    },
    {
      "id": "fda7ed85944e9d8962289de66a326eff2cd94be829b58a3bdef99383702c6311",
      "name": "Toshiba EE0A for model number(s) AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "version": "EE0A",
      "release_id": "50N1P",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-13T11:38:43Z",
      "released": "2022-04-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08344514M/2/SAS-Drive_Firmware_50N1P_WN64_EE0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=50N1P",
      "size": 12543400,
      "reboot_required": false,
      "description": "This release contains firmware version EE0A for Toshiba drives. Vendor model numbers AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "revision_history": "Fixes:\n- Improvements that reduce the risk of media errors"
    },
    {
      "id": "816d49012f9b4db14db571e5bb4d27a857a92c4b61f1a53cf912393859ae967a",
      "name": "Seagate Evans Firmware Version ESL7  for model number(s)  ST10000NM011G, ST12000NM009G, ST14000NM013G,ST16000NM010G ..",
      "version": "ESL7",
      "release_id": "NJ4NN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-29T15:04:17Z",
      "released": "2022-08-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08859853M/2/SAS-Drive_Firmware_NJ4NN_WN64_ESL7_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NJ4NN",
      "size": 13253160,
      "reboot_required": false,
      "description": "This release contains firmware version ESL7 for Seagate drives. Vendor model numbers ST10000NM011G, ST12000NM009G, ST14000NM013G,ST16000NM010G  .",
      "revision_history": "Fixes:\n- N/A\nEnhancements:-\nIncrease BMS Interval Timer.\nImprove performance for certain workloads."
    },
    {
      "id": "261ba63129d1f41b2914071e82cd4a6a82940967e80d3d8e61f5f08155c4a3a8",
      "name": "HGST LS21 for model number(s) HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.",
      "version": "LS21",
      "release_id": "MGW91",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:28Z",
      "released": "2021-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07861414M/2/SAS-Drive_Firmware_MGW91_WN64_LS21_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MGW91",
      "size": 12336240,
      "reboot_required": false,
      "description": "This release contains firmware version LS21 for HGST drives. Vendor model numbers HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "5e79a0ae39f437434e9bd58784c7071caaee4797b0d14a175c5a54b2c9ca82d3",
      "name": "Seagate KT3C for model number(s) ST900MP0026, ST600MP0036 and ST300MP0026",
      "version": "KT3C",
      "release_id": "JMP8Y",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:11Z",
      "released": "2023-08-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10267689M/2/SAS-Drive_Firmware_JMP8Y_WN64_KT3C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JMP8Y",
      "size": 12327328,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Kestrel 512n ISE.  Model Numbers ST900MP0026, ST600MP0036, ST300MP0026.\nFix FW to address drive not ready and self test issues.",
      "revision_history": "- Fix for potential drive-not-ready during boot up.\n- Fix for drive reporting incorrect progress on extended background self test."
    },
    {
      "id": "7befc05c945f5c3f654ebd22984277341f826f5c59d0f9290977ad0b4488cfa7",
      "name": "Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "version": "EK06",
      "release_id": "GTG81",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-17T06:10:13Z",
      "released": "2024-01-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11140543M/1/SAS-Drive_Firmware_GTG81_WN64_EK06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GTG81",
      "size": 12131264,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba EK06 for MG08 Air SAS 4TB program for model number(s) MG08SDA400NY",
      "revision_history": "Fixes:\n- Addresses an issue that could cause occasional read errors"
    },
    {
      "id": "5d8c2335761f5dc729d22a939ccc164e23f6c99632d2615b1482961702fec308",
      "name": "HGST KU45  for model number(s) HUS726020ALS210 and HUS726040ALS210.",
      "version": "KU45",
      "release_id": "68X4C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T17:03:19Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150772M/2/SAS-Drive_Firmware_68X4C_WN64_KU45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=68X4C",
      "size": 11746544,
      "reboot_required": false,
      "description": "This release contains firmware version KU45  for HGST drives. Vendor model numbers HUS726020ALS210 and HUS726040ALS210.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "5ea8c7f795f37f1474f7bde4e7761aa8d1ed11e034fc56a893a5ddbc7d9bc272",
      "name": "EH0D for MG06 model number(s) MG06SCA600EY, MG06SCA800EY, MG06SCA10TEY, MG06SCA10TAY, MG06SCA600AY and MG06SCA800AY",
      "version": "EH0D",
      "release_id": "4G5GY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:59:38Z",
      "released": "2022-03-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08099094M/2/SAS-Drive_Firmware_4G5GY_WN64_EH0D_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4G5GY",
      "size": 11610000,
      "reboot_required": false,
      "description": "This release contains firmware version EH0D for MG06 model number(s) MG06SCA600EY, MG06SCA800EY, MG06SCA10TEY, MG06SCA10TAY, MG06SCA600AY and MG06SCA800AY.",
      "revision_history": "Fixes:\n- Fix an issue where an unexpected power loss can cause unrecoverable read error on the following power up."
    },
    {
      "id": "618bd0ae757a5a9c20664c300ba0389e24bde3038def7b12059d452a15c0965c",
      "name": "Hitachi PU07 for Vela-A ISE model number(s) HUS726T4TALS200.",
      "version": "PU07",
      "release_id": "NNV3M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-06-12T07:41:59Z",
      "released": "2023-06-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10173148M/1/SAS-Drive_Firmware_NNV3M_WN64_PU07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NNV3M",
      "size": 13020928,
      "reboot_required": false,
      "description": "This release contains firmware version PU07 for Hitachi Vela-A ISE drives - Vendor model number(s) HUS726T4TALS200.\nNew firmware includes fix for corner case drive degradation upon sudden power loss during FW download.",
      "revision_history": "Fixes:\n- Mitigate unrecoverable drive or degraded scenarios caused by sudden power loss events when NOR flash file system is being updated.\n- Fix for issues occurring after EPO due to incorrect processing of Write Splice correction.\n- Prevent legacy (non-fast) deferred download from corrupting the current fast download state of background firmware update.\n\nEnhancements:\nN/A"
    },
    {
      "id": "7fb75a37d6d1e2e63bec2874a41942bc98af8c355fb4f027cc644ce5a54c9135",
      "name": "This release contains firmware version CSLD for STX drives. Vendor model numbers ST6000NM035A, ST8000NM014A.",
      "version": "CSLD",
      "release_id": "RJVXY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-12-06T06:20:15Z",
      "released": "2022-12-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09307700M/1/SAS-Drive_Firmware_RJVXY_WN64_CSLD_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJVXY",
      "size": 12762288,
      "reboot_required": false,
      "description": "This release contains firmware version CSLD for STX drives. Vendor model numbers ST6000NM035A, ST8000NM014A.",
      "revision_history": "Fixes:\nFix an issue where HARD_RESET primitive sequence can be missed.\nFix an issue where stale data can be returned.\nFix an issue that can cause erroneous SMART trips.\nFix an issue that can cause format corrupt.\nFix issues to ensure background scans are performed as scheduled.\nFix an issue that can cause hardware error being reported erroneously.\nFix an issue where Persistent Reservation does not persist on FW download.\nFix an issue that can cause Aborted Command error after a power cycle.\nFix an issue that can cause the drive's not being detected by the host after hot plug.\nFix an issue that can cause IOEDC error then assert.\nFix an issue that can cause IOEDC error.\nFix issues that can cause command timeout.\nFix issues that can cause assert.\nFix issues that can cause drive hang condition.\nEnhancements:\nImprove error logging / reporting accuracy.\nImprove performance for certain workloads.\nImprove SAS protocol compliance"
    },
    {
      "id": "27ea407c83dc92f02b1d6fd8458331571b111a4b1b8b129f7c9a8b86e7c4f1ef",
      "name": "Toshiba EJ09 for MG08 model number(s) MG08SCA16TEY",
      "version": "EJ09",
      "release_id": "9N3RR",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-08-18T08:52:06Z",
      "released": "2022-08-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08893938M/1/SAS-Drive_Firmware_9N3RR_WN64_EJ09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9N3RR",
      "size": 12479016,
      "reboot_required": false,
      "description": "This release contains firmware version EJ09 for MG08 model number(s) MG08SCA16TEY.",
      "revision_history": "Fixes:-\nAddresses an issue that could cause occasional read errors"
    },
    {
      "id": "52ba9199170025361e5f786bb771721f0338a90cfdd142cf80e032aa5740cc88",
      "name": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68.",
      "version": "BD48",
      "release_id": "G42W2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-07-13T11:34:31Z",
      "released": "2022-07-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08765004M/1/SAS-Drive_Firmware_G42W2_WN64_BD48_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G42W2",
      "size": 12181976,
      "reboot_required": false,
      "description": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68.",
      "revision_history": "Fixes : \n- Initial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "869cc661399eb51f8380b8e1147cebdf93446278ed18e8143f0d0bc47bd24d74",
      "name": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "version": "CSJA",
      "release_id": "WTX15",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-05-19T07:23:57Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08566987M/1/SAS-Drive_Firmware_WTX15_WN64_CSJA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WTX15",
      "size": 11271368,
      "reboot_required": false,
      "description": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSJ8.\nEnhancements:\nFixes and enhancements included are identical to those of CSJ8."
    },
    {
      "id": "e4fb2c942de5be4a8a90a693e35ee3c9f37c351de3ac1deeb79e7dbfe8ff47e4",
      "name": "Toshiba EI0D for MG07 model number(s) MG07SCA12TEY, MG07SCA14TEY and MG07SCA12TAY",
      "version": "EI0D",
      "release_id": "7DTJD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-12-01T18:26:08Z",
      "released": "2021-12-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07974223M/1/SAS-Drive_Firmware_7DTJD_WN64_EI0D_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7DTJD",
      "size": 10812392,
      "reboot_required": false,
      "description": "This release contains firmware version EI0D for MG07 model number(s) MG07SCA12TEY, MG07SCA14TEY and MG07SCA12TAY.",
      "revision_history": "Fixes:\n-Fix an issue where an unexpected power loss can cause unrecoverable read error on the following power up"
    },
    {
      "id": "ac96b1173f9112456b09633bedee46fd1648f423d66c3d36ad9ad894d0296ad4",
      "name": "HGST RS07 for Vela-AP SAS  ISE model number(s) HUS728T6TAL5200, HUS728T6TAL4200.",
      "version": "RS07",
      "release_id": "6JJPV",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-11-17T15:18:44Z",
      "released": "2021-11-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07932693M/1/SAS-Drive_Firmware_6JJPV_WN64_RS07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6JJPV",
      "size": 11484960,
      "reboot_required": false,
      "description": "This release contains firmware version HGST RS07 for Vela-AP SAS  ISE model number(s) HUS728T6TAL5200, HUS728T6TAL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    }
  ]
}
