  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "mx750c",
  "name": "MX750c",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge MX750c SAS RAID Updates",
  "filter": "sas-raid",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 38,
      "rss": "/mx750c/urgent/rss.xml",
      "api": "/api/mx750c/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 92,
      "rss": "/mx750c/recommended/rss.xml",
      "api": "/api/mx750c/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 44,
      "rss": "/mx750c/optional/rss.xml",
      "api": "/api/mx750c/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/mx750c/bios/rss.xml",
      "api": "/api/mx750c/bios"
    },
    {
      "slug": "chassis-system-management",
      "label": "Chassis System Management",
      "count": 1,
      "rss": "/mx750c/chassis-system-management/rss.xml",
      "api": "/api/mx750c/chassis-system-management"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/mx750c/chipset/rss.xml",
      "api": "/api/mx750c/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/mx750c/diagnostics/rss.xml",
      "api": "/api/mx750c/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/mx750c/drivers-for-os-deployment/rss.xml",
      "api": "/api/mx750c/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 33,
      "rss": "/mx750c/express-flash-pcie-ssd/rss.xml",
      "api": "/api/mx750c/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 9,
      "rss": "/mx750c/fibre-channel/rss.xml",
      "api": "/api/mx750c/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 2,
      "rss": "/mx750c/firmware/rss.xml",
      "api": "/api/mx750c/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/mx750c/idrac/rss.xml",
      "api": "/api/mx750c/idrac"
    },
    {
      "slug": "memory",
      "label": "Memory",
      "count": 1,
      "rss": "/mx750c/memory/rss.xml",
      "api": "/api/mx750c/memory"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 18,
      "rss": "/mx750c/network/rss.xml",
      "api": "/api/mx750c/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 45,
      "rss": "/mx750c/sas-drive/rss.xml",
      "api": "/api/mx750c/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 14,
      "rss": "/mx750c/sas-non-raid/rss.xml",
      "api": "/api/mx750c/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 13,
      "rss": "/mx750c/sas-raid/rss.xml",
      "api": "/api/mx750c/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/mx750c/security/rss.xml",
      "api": "/api/mx750c/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 29,
      "rss": "/mx750c/serial-ata/rss.xml",
      "api": "/api/mx750c/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/mx750c/systems-management/rss.xml",
      "api": "/api/mx750c/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/mx750c/video/rss.xml",
      "api": "/api/mx750c/video"
    }
  ],
  "count": 13,
  "updates": [
    {
      "id": "ddd0e2c51b4580eb2778870b68324d237a03ac014aa8e6f1d071efa03f75333c",
      "name": "BOSS-S2 Firmware",
      "version": "2.5.13.4009",
      "release_id": "TTR5R",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-25T07:01:26Z",
      "released": "2023-02-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09232098M/7/SAS-RAID_Firmware_TTR5R_WN64_2.5.13.4009_A01_06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TTR5R",
      "size": 22410088,
      "reboot_required": true,
      "description": "BOSS-S2 ROM version 2.5.13.4009",
      "revision_history": "Fixes:\n\n-- Addressed false M.2 failures reported due to thermal issues \n               \nEnhancements:\n-- Added new SDID 0x2261 on BOSS-S2 controller"
    },
    {
      "id": "40a5d823af38ca2ebe7cbf8287901fe09aafe6fca47e6048df8429e0f104815d",
      "name": "Microsoft Windows x64 management driver for BOSS",
      "version": "1.2.0.1052",
      "release_id": "8KKVC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-31T12:12:02Z",
      "released": "2021-07-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07524633M/9/SAS-RAID_Driver_8KKVC_WN64_1.2.0.1052_A02_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8KKVC",
      "size": 17014984,
      "reboot_required": false,
      "description": "Microsoft Windows x64 management driver for BOSS",
      "revision_history": "Fixes: None,\nEnhancements: YES , Signed Binaries\nConsole Management Driver for all Windows Operating systems\nSupport for Windows Azure HCI Stack \u0026 Windows 2022 enabled"
    },
    {
      "id": "e030fecbf94eb9512ae1dfa4fb776046fd4612d06268cb14e6909c5d697489ae",
      "name": "BOSS-S1 Modular firmware",
      "version": "2.6.13.3025",
      "release_id": "F9F16",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-27T11:07:40Z",
      "released": "2023-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09214778M/11/SAS-RAID_Firmware_F9F16_WN64_2.6.13.3025_A08_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F9F16",
      "size": 23542872,
      "reboot_required": true,
      "description": "BOSS-S1 Modular ROM version 2.6.13.3025",
      "revision_history": "Fixes : HW Re-spin \nAddressed false M.2 failures reported due to thermal issues\n\nEnhancements : Added new SDID 0x2260 on BOSS-S1 controller"
    },
    {
      "id": "8ad48dc6cae6e8b03aebff02644f0ded7985077dfa26073f61c431a78bdd9861",
      "name": "PERC H840 Controller Firmware 51.16.0-5148",
      "version": "51.16.0-5148",
      "release_id": "M9DDF",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-06-04T14:19:06Z",
      "released": "2023-10-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10676386M/2/SAS-RAID_Firmware_M9DDF_WN64_51.16.0-5148_A18_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M9DDF",
      "size": 19972656,
      "reboot_required": true,
      "description": "This release updates the firmware residing on H840 controllers to package 51.16.0-5148",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions, including Single Bit Errors (SBE) and Multi Bit Errors (MBE).\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown to power off the system, followed by a power on to enable the new memory settings.\nA warm reboot will NOT activate the updated settings.\nIf iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required."
    },
    {
      "id": "7a614f2dd02a71f7264337b85eb55d6adcb4d0302e69a8d71ab2c7eae29d15bf",
      "name": "PERC H755 RAID Controller firmware version 52.30.0-6753",
      "version": "52.30.0-6753",
      "release_id": "N6C86",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-06-02T16:27:30Z",
      "released": "2026-06-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14615957M/4/SAS-RAID_Firmware_N6C86_WN64_52.30.0-6753_A11_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N6C86",
      "size": 32673752,
      "reboot_required": true,
      "description": "PERC H755 RAID Controller firmware version 52.30.0-6753",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions, including Single Bit Errors (SBE) and Multi Bit Errors (MBE).\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown to power off the system, followed by a power on to enable the new memory settings.\nA warm reboot will NOT activate the updated settings.\nIf iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required."
    },
    {
      "id": "6306f393fcf55eebf9d3f106b79f5cb2e14149c9e26bbb21c7c01265844a670a",
      "name": "Windows Server 2022 Driver  for PERC Controllers",
      "version": "7.730.02.00",
      "release_id": "6R1TD",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-04-01T19:07:45Z",
      "released": "2024-10-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12935196M/1/SAS-RAID_Driver_6R1TD_WN64_7.730.02.00_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6R1TD",
      "size": 14519504,
      "reboot_required": true,
      "description": "This release updates Windows 2022 Server driver to 7.730.02.00 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers.",
      "revision_history": "Fixed MPI registers read may return value of 0 in SecureMode\nFixed firmware update error"
    },
    {
      "id": "9919a72526e3192f77c158c625e5ec4efa06638905b3c239de5820e669db369e",
      "name": "BOSS Console Management driver for WS2022-2025",
      "version": "1.2.0.1055",
      "release_id": "7004G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-12-18T11:18:14Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11846807M/2/SAS-RAID_Driver_7004G_WN64_1.2.0.1055_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7004G",
      "size": 12936864,
      "reboot_required": false,
      "description": "BOSS Console Management driver for WS2022-2025",
      "revision_history": "Fixes: None,\nEnhancements: Console Management Driver enablement for MS Windows 2025."
    },
    {
      "id": "0d4287adf1ed4f2f517ff38b33876fed6b2a07d27801c215d5210424511a06b7",
      "name": "Windows Server 2025 Driver 7.729.01.00 for PERC Controllers",
      "version": "7.729.01.0",
      "release_id": "15N54",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-10-10T14:11:09Z",
      "released": "2024-10-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12201040M/1/SAS-RAID_Driver_15N54_WN64_7.729.01.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=15N54",
      "size": 6216024,
      "reboot_required": true,
      "description": "This is the initial release of the Windows 2025 Server driver to 7.729.01.0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers.",
      "revision_history": "Fixes:\n- N/A\n\nEnhancements:\n- N/A"
    },
    {
      "id": "1cf0b85f5925478d856211e96cf74a43eda961b3784b44f8fb3aa84cc783de08",
      "name": "Windows Server 2025 64bit driver for PERC S150 Controller",
      "version": "6.8.0.0001",
      "release_id": "7M8G6",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2024-06-24T07:01:10Z",
      "released": "2024-06-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11769642M/1/SAS-RAID_Driver_7M8G6_WN64_6.8.0.0001_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7M8G6",
      "size": 6640784,
      "reboot_required": true,
      "description": "Windows Server 2025 64bit driver for PERC S150 Controller"
    },
    {
      "id": "744dcccc63193f44275c6cdb20efc6b471b00f156a4be43ab2e14a3586ea99a6",
      "name": "Windows Server 2022 64bit driver for PERC S150 Controller",
      "version": "6.7.0.0003",
      "release_id": "26KG9",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2024-03-26T16:03:30Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422737M/1/SAS-RAID_Driver_26KG9_WN64_6.7.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=26KG9",
      "size": 6625096,
      "reboot_required": true,
      "description": "Windows Server 2022 64bit driver for PERC S150 Controller"
    },
    {
      "id": "8b123fe887879d8ad789dc986b35da9f2ec22affe26654a6bb6e8b20640f3cc6",
      "name": "Windows Server 2019 64bit driver for PERC S150 Controller",
      "version": "6.7.0.0003",
      "release_id": "XVCP2",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T16:00:59Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422723M/1/SAS-RAID_Driver_XVCP2_WN64_6.7.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XVCP2",
      "size": 6625104,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S150 Controller"
    },
    {
      "id": "ca5606e16fe90737d16d3ad62791699277b9e8b9cec2b708b59595c6062d5e22",
      "name": "PERC H745P MX Controller Firmware version 51.16.0-5150",
      "version": "51.16.0-5150",
      "release_id": "RJRYG",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-06T19:02:27Z",
      "released": "2023-10-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10676422M/3/SAS-RAID_Firmware_RJRYG_WN64_51.16.0-5150_A09_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJRYG",
      "size": 11915512,
      "reboot_required": true,
      "description": "PERC H745P MX Controller Firmware version: 51.16.0-5150",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions, including Single Bit Errors (SBE) and Multi Bit Errors (MBE).\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown to power off the system, followed by a power on to enable the new memory settings.\nA warm reboot will NOT activate the updated settings.\nIf iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required.\nFirmware downgrade from version 50.5.0-1750 or greater to a lower version while in Enhanced -HBA mode is not supported.\nFirmware downgrade from version 50.5.1-2633 or greater to a lower version while in OpenManage Secure Enterprise Key Manager mode is not supported.\n-H745P MX only support firmware version 50.3.0-1512 or greater\n-See SAS_RAID_Firmware_RJRYG_51.16.0-5150_A09_RELNOTES.txt file for additional important information"
    },
    {
      "id": "1bd85f6bd394bc927689e01db4206561ec946a6b01a7579299d2a9ee26ef0920",
      "name": "Windows Server 2019 Driver 7.726.01.0 for PERC Controllers",
      "version": "7.726.01.0",
      "release_id": "44R58",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-02T22:15:59Z",
      "released": "2023-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10807826M/1/SAS-RAID_Driver_44R58_WN64_7.726.01.0_A09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=44R58",
      "size": 6196192,
      "reboot_required": true,
      "description": "This release updates Windows 2019 Server driver to 7.726.01.0 for PERC H740P, H840, H745P MX, H745 Adapter, H745 Front, H345 Adapter, H345 Front, H755 Front, H755N, H755 Adapter, H755 MX, H750 Adapter, H355 Adapter, H355 Front, and H350 Adapter controllers."
    }
  ]
}