  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "mx740c",
  "name": "MX740c",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge MX740c SAS Drive Updates",
  "filter": "sas-drive",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 44,
      "rss": "/mx740c/urgent/rss.xml",
      "api": "/api/mx740c/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 129,
      "rss": "/mx740c/recommended/rss.xml",
      "api": "/api/mx740c/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 51,
      "rss": "/mx740c/optional/rss.xml",
      "api": "/api/mx740c/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/mx740c/bios/rss.xml",
      "api": "/api/mx740c/bios"
    },
    {
      "slug": "chassis-system-management",
      "label": "Chassis System Management",
      "count": 1,
      "rss": "/mx740c/chassis-system-management/rss.xml",
      "api": "/api/mx740c/chassis-system-management"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/mx740c/chipset/rss.xml",
      "api": "/api/mx740c/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/mx740c/diagnostics/rss.xml",
      "api": "/api/mx740c/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/mx740c/drivers-for-os-deployment/rss.xml",
      "api": "/api/mx740c/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 35,
      "rss": "/mx740c/express-flash-pcie-ssd/rss.xml",
      "api": "/api/mx740c/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 16,
      "rss": "/mx740c/fibre-channel/rss.xml",
      "api": "/api/mx740c/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 3,
      "rss": "/mx740c/firmware/rss.xml",
      "api": "/api/mx740c/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/mx740c/idrac/rss.xml",
      "api": "/api/mx740c/idrac"
    },
    {
      "slug": "memory",
      "label": "Memory",
      "count": 3,
      "rss": "/mx740c/memory/rss.xml",
      "api": "/api/mx740c/memory"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 32,
      "rss": "/mx740c/network/rss.xml",
      "api": "/api/mx740c/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 69,
      "rss": "/mx740c/sas-drive/rss.xml",
      "api": "/api/mx740c/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 3,
      "rss": "/mx740c/sas-non-raid/rss.xml",
      "api": "/api/mx740c/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 13,
      "rss": "/mx740c/sas-raid/rss.xml",
      "api": "/api/mx740c/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 39,
      "rss": "/mx740c/serial-ata/rss.xml",
      "api": "/api/mx740c/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/mx740c/systems-management/rss.xml",
      "api": "/api/mx740c/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/mx740c/video/rss.xml",
      "api": "/api/mx740c/video"
    }
  ],
  "count": 69,
  "updates": [
    {
      "id": "559e792d7369318d22be9a9b8c82cb7c3e6f91193952b11ebf8a9ba38e90ab7c",
      "name": "Toshiba EF0A for model number(s) AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY",
      "version": "EF0A",
      "release_id": "THG5M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T06:27:04Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607520M/2/SAS-Drive_Firmware_THG5M_WN64_EF0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=THG5M",
      "size": 26661096,
      "reboot_required": false,
      "description": "This release contains firmware version EF0A for Toshiba drives. Vendor model numbers AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures.\n- Fixed Command timeout (or 06/29/04) issue.\n  This problem may occur when the queued time for a read or write command \n  exceeds the Command Aging Timer and the SYNCHRONIZED CACHE \n  command is also queued.\n- Fixed random write iops degradation after sequential read.\n    4k Random write -\u003e Seq read -\u003e 4k random write. In this test sequence, \n    2nd 4k random write iops may drop.\n- Fixed a wrong LBA report in SENSE DATA when Read Buffer CRC \n    error(03/11/02) occurs."
    },
    {
      "id": "fdd84063aa261dc77f4bd896bc2458570e08fd9fa0f7c7a07d843154dbc72955",
      "name": "Initial release of Toshiba AL15SE+ HDD Model Number AL15SEB09EQY",
      "version": "EF82",
      "release_id": "VJWX0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T04:21:30Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607338M/2/SAS-Drive_Firmware_VJWX0_WN64_EF82_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJWX0",
      "size": 26660216,
      "reboot_required": false,
      "description": "This release contains firmware version EF82 for Toshiba drives. Vendor Model Number AL15SEB09EQY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures."
    },
    {
      "id": "41d8ddf307b4ef32924e88af9618acf8165484bb258955e0c6381fffd74cec21",
      "name": "Seagate SBTA for Skybolt ServoBP program for model number(s) CL2400MM0149",
      "version": "SBTA",
      "release_id": "HH6J1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:02:18Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12677112M/2/SAS-Drive_Firmware_HH6J1_WN64_SBTA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HH6J1",
      "size": 23874432,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512n ISE. Model Number CL2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "4c6ed6166ab2e1a3e699af648e5457cd81edd18f87e2beea7561f7262fa1fa6d",
      "name": "Seagate SBSA for Skybolt ServoBP program for model number(s) BL2400MM0159",
      "version": "SBSA",
      "release_id": "00P56",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:22:58Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676520M/2/SAS-Drive_Firmware_00P56_WN64_SBSA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=00P56",
      "size": 23874416,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512e ISE.  Model Number BL2400MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "3327174b72088c6b72541588c503c14db0065a16884a08012949b2120919cf43",
      "name": "Seagate ST7G for model number(s) ST1800MM0159 and ST2400MM0159",
      "version": "ST7G",
      "release_id": "7N5DH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:05:15Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676236M/4/SAS-Drive_Firmware_7N5DH_WN64_ST7G_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7N5DH",
      "size": 23857864,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Skybolt 4Kn ISE.  Model Numbers ST2400MM0159 and ST1800MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "d5b4cea0b433c0dc5f334945213d8a951654857385c555988b21866cfaa38c0c",
      "name": "Firmware refresh for Seagate ST5J for model number(s) DL1800MM0159 and DL2400MM0159",
      "version": "ST5J",
      "release_id": "DRHV4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:02:48Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12671974M/4/SAS-Drive_Firmware_DRHV4_WN64_ST5J_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DRHV4",
      "size": 23857936,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512e ISE.  Model Numbers DL2400MM0159 and DL1800MM0159.",
      "revision_history": "Firmware modification to add support for new V8 NAND part."
    },
    {
      "id": "56221de0237fbeeb680e5eac2cb8d3e0f72799000d1986cf8fb68d7d02d297cd",
      "name": "Seagate SSEJ for model number(s) ST2400MM0149",
      "version": "SSEJ",
      "release_id": "KHJ9C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:13:51Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676334M/3/SAS-Drive_Firmware_KHJ9C_WN64_SSEJ_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHJ9C",
      "size": 24679816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512n ISE. Model Number ST2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "- Add support for Hynix V8 NAND part."
    },
    {
      "id": "ceff23d80cbb8541baa365b1fd0640fa4a06d13481f5404c1fc5497f6dbd404c",
      "name": "Seagate SSC8 for model number(s) ST1200MM0069",
      "version": "SSC8",
      "release_id": "P9R4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:08:58Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11500432M/2/SAS-Drive_Firmware_P9R4D_WN64_SSC8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P9R4D",
      "size": 24522608,
      "reboot_required": false,
      "description": "This release contains firmware version SSC8 for Seagate drives. Vendor model numbers ST1200MM0069..",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "771aacec8b2f181d2931276a870acf035ada5af80f2174a808e8f6fe28a17150",
      "name": "HGST RS09 for Vela-AP SAS  ISE model number(s) HUS728T6TAL5200, HUS728T6TAL4200",
      "version": "RS09",
      "release_id": "8GM6M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-04-11T11:06:44Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025815M/2/SAS-Drive_Firmware_8GM6M_WN64_RS09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8GM6M",
      "size": 24607448,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SAS HDD, Model number HUS728T6TAL5200.\nFW update for WDC Vela-AP 4Kn SAS HDD, Model number HUS728T6TAL4200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "9d3a909718077b49b7c8c9902c53facf85f1cfdfc24edabfce073cd264cc800c",
      "name": "Hitachi PU09 for Vela-A ISE model number(s) HUS726T4TALS200",
      "version": "PU09",
      "release_id": "J5K8G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T11:03:41Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024400M/2/SAS-Drive_Firmware_J5K8G_WN64_PU09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J5K8G",
      "size": 24727008,
      "reboot_required": false,
      "description": "FW update for WDC Vela-A 512n SAS HDD, Model number HUS726T4TALS200.\n\n- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "6cb9b2e14559a89fe993a07e8c8367a371dc1253168afd133677270b5bcb3eec",
      "name": "Seagate ST38 for model number(s) ST600MM0069 and ST1200MM0099",
      "version": "ST38",
      "release_id": "FFN16",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T10:22:22Z",
      "released": "2024-05-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11502881M/2/SAS-Drive_Firmware_FFN16_WN64_ST38_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FFN16",
      "size": 24522520,
      "reboot_required": false,
      "description": "This release contains firmware version ST38 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes:\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "736e89923bb3c28df28dc52a33909657ef3c7f17816fa6be7cd3ade0082728b9",
      "name": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "version": "C40E",
      "release_id": "57MM2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:28:10Z",
      "released": "2024-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374876M/2/SAS-Drive_Firmware_57MM2_WN64_C40E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=57MM2",
      "size": 24391360,
      "reboot_required": false,
      "description": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "revision_history": "Fixes: \n\n- Fix1: FW is fixed to execute the flush process and Flash Memory parameter modification process exclusively.\n- Fix2: Fixed that the host I/O proceed by the skip of GC if the validity determination process of user data takes time.\n- Fix3: Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "2d586d18bf6bfd668a4b76e782765a56bb78bffe1a219c60613e9b1ae474dbde",
      "name": "Model numbers are KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8, KPM7XRUG960G, KPM7XVUG800G, KPM7XMUG400G, KPM7XMUG800G, KPM7XMUG1T60",
      "version": "C10E",
      "release_id": "T21WT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:11:55Z",
      "released": "2024-06-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374981M/2/SAS-Drive_Firmware_T21WT_WN64_C10E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T21WT",
      "size": 24314272,
      "reboot_required": false,
      "description": "This release contains firmware version C10E for Kioxia PM7 24Gbps SAS 2.5 (10WPD, 1WPD, 3WPD).\nModel numbers are KPM7XMUG400G, KPM7XMUG800G, and KPM7XMUG1T60,\nKPM7XVUG800G, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8,KPM7XRUG960G, KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3.",
      "revision_history": "Fix:\n\n-  Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "0776b5d687d3fbafca1eb2f20fa128d1b4ec7423dcc2fefe3e9f3387ab95092f",
      "name": "Kioxia BA48 FW for PM6 drives for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "version": "BA48",
      "release_id": "NGPR2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T05:55:37Z",
      "released": "2022-09-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08764563M/4/SAS-Drive_Firmware_NGPR2_WN64_BA48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NGPR2",
      "size": 24171504,
      "reboot_required": false,
      "description": "Kioxia PM6 BA48 FW for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "revision_history": "Fixes:\nInitial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "ee1dd07dfa56c50a22f52b957c6eea53779375c00ea310b32677d2cc45dccbfd",
      "name": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68",
      "version": "BD48",
      "release_id": "6DH0W",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-07T09:55:22Z",
      "released": "2023-10-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10704397M/4/SAS-Drive_Firmware_6DH0W_WN64_BD48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6DH0W",
      "size": 24247952,
      "reboot_required": false,
      "description": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68.",
      "revision_history": "Fixes :\n- Initial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "2189d3c19f564af9c4adadb58dd81c7b80feda3edd4af1e38e757fc10724ae62",
      "name": "HGST EU46  for model number(s) HUC156030CSS200 and HUC156060CSS200",
      "version": "EU46",
      "release_id": "R39JH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T09:18:31Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12886071M/1/SAS-Drive_Firmware_R39JH_WN64_EU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R39JH",
      "size": 24103776,
      "reboot_required": false,
      "description": "This release contains firmware version EU46 FW changes to affect HGST King Cobra F 512n SAS ISE HDD, Model numbers HUC156060CSS200 and HUC156030CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "710a41520969170b139a0ad46b68638dc89b3cc9bed271ae5f33137141cd804d",
      "name": "HGST EK46 for model number(s) HUC156060CS4204",
      "version": "EK46",
      "release_id": "M04KK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T07:22:10Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12885013M/1/SAS-Drive_Firmware_M04KK_WN64_EK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M04KK",
      "size": 24112472,
      "reboot_required": false,
      "description": "This release contains firmware version EK46 'FW changes to affect HGST King Cobra F 4Kn SAS HDD, Model number HUC156060CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "be8cba2fe69053e9785264bea3fc29c4b30fe84a8cd65e095c114f2e7bbbf350",
      "name": "HGST EJ46  for model number(s) HUC156030CSS204,and HUC156060CSS204",
      "version": "EJ46",
      "release_id": "H53FC",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T06:20:55Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12884528M/1/SAS-Drive_Firmware_H53FC_WN64_EJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H53FC",
      "size": 24103728,
      "reboot_required": false,
      "description": "This release contains firmware version EJ46 'FW changes to affect HGST King Cobra F 512n SAS HDD, Model numbers HUC156060CSS204 and HUC156030CSS204.\nIncludes FW change to turn off drive usage logging to avoid pointer error",
      "revision_history": "Fixes:\nFixes: FW change to turn off drive usage logging to avoid pointer error"
    },
    {
      "id": "c69c0d7de49ad38ad0c52ed4cc69e17677fb3881869c747bd9a110e6b4c8bb73",
      "name": "HGST FU46  for model number(s) HUC101830CSS200, HUC101812CSS200 and HUC101860CSS200",
      "version": "FU46",
      "release_id": "DH7TM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T11:00:24Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880083M/1/SAS-Drive_Firmware_DH7TM_WN64_FU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DH7TM",
      "size": 24083696,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512n SAS ISE HDD, Model numbers  HUC101830CSS200, HUC101860CSS200, and HUC101812CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "cd1d62fa296afde305b57d1c8c09a670b8c62765e8c4a61a2570f61f4ffede28",
      "name": "HGST FK46 for model number(s) HUC101818CS4204 and HUC101818CS4204",
      "version": "FK46",
      "release_id": "V917M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T10:23:21Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880005M/1/SAS-Drive_Firmware_V917M_WN64_FK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V917M",
      "size": 24091240,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512e and 4Kn SAS HDD , Model number HUC101818CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\n'FW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "2f758b11765da0fb1b02a4e543dc569c690272a2b0b6e0aa0bfc0776af21817b",
      "name": "HGST FJ46  for model number(s) HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204",
      "version": "FJ46",
      "release_id": "DYYN1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T09:12:02Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12879555M/1/SAS-Drive_Firmware_DYYN1_WN64_FJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DYYN1",
      "size": 24083632,
      "reboot_required": false,
      "description": "This release contains FW changes to affect HGST Cobra F 512n SAS HDD, Model numbers HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204 includes FW change to turn off drive usage logging to avoid pointers error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointers error."
    },
    {
      "id": "3da2d1c93d40ba01200cdc48b85bb0f0a85dcb6e489b9eaa0d9d32bcbf861b9f",
      "name": "HGST PS09 for Vela-A ISE model number(s) HUS726T6TAL4200 and HUS726T6TAL5200",
      "version": "PS09",
      "release_id": "8MJFT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T07:20:39Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024641M/1/SAS-Drive_Firmware_8MJFT_WN64_PS09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8MJFT",
      "size": 13464192,
      "reboot_required": false,
      "description": "This release contains firmware version PS09 for HGST Vela-A ISE drives - Vendor model number(s) HUS726T6TAL4200 and HUS726T6TAL5200.\n'FW update for WDC Vela-A 512e SAS HDD, Model number HUS726T6TAL5200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "a3327e1940b3fe3b81e47fa9d3bb7aeffd6956b5f4ee06f4a9f14c97f3c83a19",
      "name": "Samsung PM1653 drives for DSG9 FW for model numbers MZILG960HCHQAD3, MZILG1T9HCJRAD3, MZILG3T8HCLSAD3, MZILG7T6HBLAAD3 and MZILG15THBLAAD3",
      "version": "DSG9",
      "release_id": "3MV58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T17:20:50Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11939710M/1/SAS-Drive_Firmware_3MV58_WN64_DSG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3MV58",
      "size": 13264392,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count acuracy and drive temperature reporting during format operations. Firmware version DSG9 for Samsung PM1653 drives. Vendor model numbers MZILG960HCHQ-0AD3, MZILG1T9HCJR-0AD3, MZILG3T8HCLS-0AD3, MZILG7T6HBLA-0AD3, and MZILG15THBLA-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "e15c231399536e80009d372366b4e72a4c66dedf951ad1fa78d1309ab3e37961",
      "name": "Samsung PM1655 drives for FW DWG9 for model numbers MZILG800HCHQAD3, MZILG1T6HCJRAD3 and MZILG3T2HCLSAD3",
      "version": "DWG9",
      "release_id": "7MTXM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T08:00:58Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11937657M/1/SAS-Drive_Firmware_7MTXM_WN64_DWG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7MTXM",
      "size": 13261200,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count accuracy and drive temperature reporting during format operations. Firmware version DWG9 for Samsung PM1655 drives. Vendor model numbers MZILG800HCHQ-0AD3, MZILG1T6HCJR-0AD3, and MZILG3T2HCLS-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "baa5cac92e3b072bd227668372c2c7520ed3e15c5a55003853c701aa0df1e8a2",
      "name": "HGST J17L for model number(s) HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "version": "J17L",
      "release_id": "0NKFF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-31T05:53:56Z",
      "released": "2024-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11625826M/3/SAS-Drive_Firmware_0NKFF_WN64_J17L_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0NKFF",
      "size": 12890680,
      "reboot_required": false,
      "description": "This release contains firmware version J17L for HGST drives. Vendor model numbers HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "revision_history": "External: FW update for HGST Bear Cove MLC 3WPD SAS HDD, Model numbers HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200, HUSMR3232ASS200.\nIncludes FW fix to free space buffer calculation to avoid a potential assert condition resulting in a self-initiated reset."
    },
    {
      "id": "2d691ed72b31c474544f0a9a0818d69f0e4ab820992ea73115f41143fafef850",
      "name": "WD BCQ firmware G138  for model numbers WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200,WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200,WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200",
      "version": "G138",
      "release_id": "8W5WF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T07:34:09Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11655805M/1/SAS-Drive_Firmware_8W5WF_WN64_G138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8W5WF",
      "size": 12585960,
      "reboot_required": false,
      "description": "This release contains firmware version G138 for WD BCQ drives. Vendor model numbers WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200, WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200, WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries."
    },
    {
      "id": "13796d98c89ff1cc8cda76d598f7dfe5ccc925a8fadfd3999fb71e9fbcb079fb",
      "name": "WDC Bear Cove Quantum FIPS-140 L138 for 1WPD and 3WPD  model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205,WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "version": "L138",
      "release_id": "16C85",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T05:58:21Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11654668M/1/SAS-Drive_Firmware_16C85_WN64_L138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=16C85",
      "size": 12580296,
      "reboot_required": false,
      "description": "This release contains firmware version L138 for WDC Bear Cove Quantum FIPS-140 1WPD and 3WPD. For model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205, WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "8a52d319629e11204664327b05fd87cb5acb389f411981023123bd2d220b1dee",
      "name": "WDC/HGST Bear Cove TLC RI, SSD, 12Gbps SAS, 2.5, 512e, ISE, FW S545 for model number(s) HUSTR7648ASS200, HUSTR7696ASS200, HUSTR7619ASS200, HUSTR7638ASS200 and HUSTR7676ASS200.",
      "version": "S545",
      "release_id": "3HTHY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-08T19:57:02Z",
      "released": "2024-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11591721M/1/SAS-Drive_Firmware_3HTHY_WN64_S545_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3HTHY",
      "size": 12951728,
      "reboot_required": false,
      "description": "This release contains firmware version S545 for WDC/HGST Bear Cove TLC RI, SSD, 12Gbps SAS, 2.5, 512e, ISE.. Vendor model numbers HUSTR7648ASS200, HUSTR7696ASS200, HUSTR7619ASS200, HUSTR7638ASS200 and HUSTR7676ASS200.",
      "revision_history": "FW change to correct a free space buffer calculation error to avoid a potential assert which would result in a self-initiated reset."
    },
    {
      "id": "333f510745d6bedcbadf00dfa27e5b7532c32ae94fea09bd9ec4a93617b1329f",
      "name": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s)  KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960",
      "version": "CA0C",
      "release_id": "1YD58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T15:53:43Z",
      "released": "2023-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10810459M/2/SAS-Drive_Firmware_1YD58_WN64_CA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1YD58",
      "size": 12708760,
      "reboot_required": false,
      "description": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s) KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960G.",
      "revision_history": "Fixes: \nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed in a different area, the drive may encounter the below failure mode. Once a drive falls into this failure mode, it cannot be recovered by power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. Data buffer is used for data transfer during Wear-Leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow.                                                                                                             Write Cache Issue: An issue that may cause firmware downloads to fail in the event of a capacitor failure. This failure is triggered by firmware download in the Write Cache Off state, and even if it occurs, it does not lead to drive failure and can be recovered by a reset or Power cycle.\nCause: When FW Update is executed in the Write Cache Off state and then restarted, capacitor discharge control is activated. In this case, unintended PLP occurs because capacitor discharge was controlled in the order of capacitor discharge and then PLP interrupt mask.\nFix: When capacitor discharge control is executed after FW Update in the Write Cache Off state and the system is restarted, the PLP interrupt mask is changed to control in the order of PLP interrupt mask and then capacitor discharge."
    },
    {
      "id": "a1178484b04285ac191ec9219242d56e944c47e79f02b74de40e05534be8c7b3",
      "name": "Seagate SBW6 for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "version": "SBW6",
      "release_id": "5G3PW",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T06:30:37Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11496475M/1/SAS-Drive_Firmware_5G3PW_WN64_SBW6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5G3PW",
      "size": 13261504,
      "reboot_required": false,
      "description": "This release contains firmware version SBW6 Seagate for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "revision_history": "Fixes:\n\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "fda7ed85944e9d8962289de66a326eff2cd94be829b58a3bdef99383702c6311",
      "name": "Toshiba EE0A for model number(s) AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "version": "EE0A",
      "release_id": "50N1P",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-13T11:38:43Z",
      "released": "2022-04-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08344514M/2/SAS-Drive_Firmware_50N1P_WN64_EE0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=50N1P",
      "size": 12543400,
      "reboot_required": false,
      "description": "This release contains firmware version EE0A for Toshiba drives. Vendor model numbers AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "revision_history": "Fixes:\n- Improvements that reduce the risk of media errors"
    },
    {
      "id": "8b7171c9e267a84502b4dd3b631bc09cc0e0ab25b12cc110d8273af3b0f84615",
      "name": "Seagate 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "version": "4S0C",
      "release_id": "G04C8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-12T12:12:27Z",
      "released": "2022-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08459420M/2/SAS-Drive_Firmware_G04C8_WN64_4S0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G04C8",
      "size": 12625072,
      "reboot_required": false,
      "description": "This release contains Seagate firmware version 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "revision_history": "Fixes:\n-Fix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\n-Fix an issue that can return corrupt data after a power cycle in a corner case.\n-Fix an issue that can return the sense code 09/80/00 to a WRITE command.\n-Fix issues that can cause command timeout.\n-Fix issues that can cause drive assert.\n-Fix issues that can cause drive hang condition.\n\nEnhancements:\n-Improve protocol spec compliance.\n-Improve throughput performance for specific workloads.\n-Improve error logging/sense data reporting.\n-\nFix an issue that can cause drive-not-ready."
    },
    {
      "id": "dc4d9b31b476ffc086c28441a7060b994ff12bd8c7791266534a46aca19bec06",
      "name": "Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "version": "B02A",
      "release_id": "CPP97",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-12T04:37:43Z",
      "released": "2024-02-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11252185M/1/SAS-Drive_Firmware_CPP97_WN64_B02A_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CPP97",
      "size": 12644544,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "revision_history": "Fixes: \n\nFix1:  \n- A) When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  B) FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.                                                                                                                                                                              \nFix 2:\n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\nFix 3:\n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "00468fc0260e621a877723a344475d07853b33dfb806cc08c1add6b63e2f522d",
      "name": "Samsung DSLA for model number(s) MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "version": "DSLA",
      "release_id": "XNGNT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-24T07:44:11Z",
      "released": "2020-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06510985M/4/SAS-Drive_Firmware_XNGNT_WN64_DSLA_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XNGNT",
      "size": 12464696,
      "reboot_required": false,
      "description": "This release contains firmware version DSLA for Samsung drives. Vendor model numbers MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "revision_history": "Fixes:\n - Incorrect Metadata returned after power cycle\n - UECC report but normal cell distribution\n - PLP Fail During Write Same"
    },
    {
      "id": "677e3a67b1c439fdecfba818e628b71070c6c8cd014d8ffde7fd59542c47a6d2",
      "name": "Samsung DWLA for model number(s) MZILS400HEGR0D3, MZILS800HEHP0D3, MZILS1T6HEJH0D3 and MZILS3T2HMLH0D3.",
      "version": "DWLA",
      "release_id": "K53JY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-23T15:58:32Z",
      "released": "2020-08-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06462498M/3/SAS-Drive_Firmware_K53JY_WN64_DWLA_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K53JY",
      "size": 12040464,
      "reboot_required": false,
      "description": "This release contains firmware version DWLA for Samsung drives. Vendor model numbers MZILS400HEGR0D3, MZILS800HEHP0D3, MZILS1T6HEJH0D3 and MZILS3T2HMLH0D3.",
      "revision_history": "Fixes:\n - Incorrect Metadata returned after power cycle\n - UECC report but normal cell distribution\n - PLP Fail During Write Same"
    },
    {
      "id": "0f2aad04e3d715fe60af5cb8dca609f6a76e3d07ca5f0ab96be68d1f12b515a0",
      "name": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "version": "B326",
      "release_id": "7FV43",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T11:30:04Z",
      "released": "2024-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11166204M/1/SAS-Drive_Firmware_7FV43_WN64_B326_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7FV43",
      "size": 12699824,
      "reboot_required": false,
      "description": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "revision_history": "Fixes: \n\nFix1:  \n- When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  Fixed FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.\n                                                                                                                                                                                   \nFix 2: \n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\n\nFix 3: \n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "5086e78dc030867d4946fe97008ff36bf0257aa011025b9bd1e283a60cc72e2d",
      "name": "Samsung PM1645a drive for FW DWA4 for Model number(s):MZILT800HBHQ0D3, MZILT1T6HBJR0D3, MZILT3T2HBLS0D3.",
      "version": "DWA4",
      "release_id": "VJY6V",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:39:09Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08613033M/2/SAS-Drive_Firmware_VJY6V_WN64_DWA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJY6V",
      "size": 11323344,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1645a drive for Model number(s):MZILT800HBHQ0D3, MZILT1T6HBJR0D3, MZILT3T2HBLS0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "35eac7069698f618d06d9c9ea299c75e9b17bddc06457ca22fb16eb38e38a7d9",
      "name": "Samsung DSF8 for model number(s) MZILT960HAHQ0D3, MZILT1T9HAJQ0D3, MZILT3T8HALS0D3, MZILTZ7T6HMLA0D3, and MZILT15HMLA0D3.",
      "version": "DSF8",
      "release_id": "J3RRK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:14:50Z",
      "released": "2021-01-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06899246M/2/SAS-Drive_Firmware_J3RRK_WN64_DSF8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J3RRK",
      "size": 11483448,
      "reboot_required": false,
      "description": "This release contains firmware version DSF8 for Samsung drives. Vendor model numbers MZILT960HAHQ0D3, MZILT1T9HAJQ0D3, MZILT3T8HALS0D3, MZILTZ7T6HMLA0D3, and MZILT15HMLA0D3."
    },
    {
      "id": "261ba63129d1f41b2914071e82cd4a6a82940967e80d3d8e61f5f08155c4a3a8",
      "name": "HGST LS21 for model number(s) HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.",
      "version": "LS21",
      "release_id": "MGW91",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:28Z",
      "released": "2021-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07861414M/2/SAS-Drive_Firmware_MGW91_WN64_LS21_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MGW91",
      "size": 12336240,
      "reboot_required": false,
      "description": "This release contains firmware version LS21 for HGST drives. Vendor model numbers HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "5e79a0ae39f437434e9bd58784c7071caaee4797b0d14a175c5a54b2c9ca82d3",
      "name": "Seagate KT3C for model number(s) ST900MP0026, ST600MP0036 and ST300MP0026",
      "version": "KT3C",
      "release_id": "JMP8Y",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:11Z",
      "released": "2023-08-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10267689M/2/SAS-Drive_Firmware_JMP8Y_WN64_KT3C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JMP8Y",
      "size": 12327328,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Kestrel 512n ISE.  Model Numbers ST900MP0026, ST600MP0036, ST300MP0026.\nFix FW to address drive not ready and self test issues.",
      "revision_history": "- Fix for potential drive-not-ready during boot up.\n- Fix for drive reporting incorrect progress on extended background self test."
    },
    {
      "id": "121c2c65e1e9a03b00d25ba579c34f484234d576609fe0ed7e6c5860d47a0e0b",
      "name": "Samsung PM1643a drives for FW DSA4 for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "version": "DSA4",
      "release_id": "D7RNT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:05:17Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08612628M/2/SAS-Drive_Firmware_D7RNT_WN64_DSA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D7RNT",
      "size": 11328112,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1643a drives for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "c3fa3bfa4a100d08fcfd210bbb17970e2f94364f62672e9c9ed24ddf6eba2cee",
      "name": "Seagate KSCC for model number(s) ST900MP0126",
      "version": "KSCC",
      "release_id": "MG6NK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:04:43Z",
      "released": "2023-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09833994M/2/SAS-Drive_Firmware_MG6NK_WN64_KSCC_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MG6NK",
      "size": 12280816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Kestrel 512n FIPS. Model Number ST900MP0126.\nFix FW to address drive not ready and self test issues.",
      "revision_history": "- Fix for potential drive-not-ready during boot up.\n- Fix for drive reporting incorrect progress on extended background self test."
    },
    {
      "id": "f9290eb3b74efc450be944a10ae52b87ef4989382da72c3cd6b1a85e58859631",
      "name": "Seagate 3D03  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "version": "3D03",
      "release_id": "NKGWD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:03:59Z",
      "released": "2022-12-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09072701M/2/SAS-Drive_Firmware_NKGWD_WN64_3D03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKGWD",
      "size": 11993080,
      "reboot_required": false,
      "description": "This release contains firmware version 3D03 Seagate  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "revision_history": "Fixes:\nFix the drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can make the drive return 0B/44 to all commands until power cycled.\nFix issues that can cause drive assert.\nFix issues that can cause command timeout.\nFix issues that can cause drive-not-ready, including the case that can happen after power-cycle.\nFix issues that can cause drive hang condition.\nEnhancements:\nImprove error logging/sense data reporting."
    },
    {
      "id": "a08ca9a1bf4c85e589749c6ee784bef8f7efcf512afb12fbf2b0b1ffc38c6da7",
      "name": "Toshiba AS10 for model number(s) PX05SMB320Y, PX05SMB160Y, PX05SMB080Y, PX05SMB040Y, PX05SVB384Y, PX05SVB192Y, PX05SVB096Y, PX05SVB048Y, PX05SRB384Y, PX05SRB192Y, PX05SRB096Y and PX05SRB048Y.",
      "version": "AS10",
      "release_id": "1DJXX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-16T06:54:21Z",
      "released": "2019-09-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05601933M/2/SAS-Drive_Firmware_1DJXX_WN64_AS10_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1DJXX",
      "size": 12379416,
      "reboot_required": false,
      "description": "This release contains firmware version AS10 for Toshiba drives. Vendor model numbers PX05SMB320Y, PX05SMB160Y, PX05SMB080Y, PX05SMB040Y, PX05SVB384Y, PX05SVB192Y, PX05SVB096Y, PX05SVB048Y, PX05SRB384Y, PX05SRB192Y, PX05SRB096Y and PX05SRB048Y.",
      "revision_history": "Fixes:\n - Modify the Wear Leveling algorithm so that the F/W searches deeper into free super block pool. The depth for search depends on the drive capacity.\n- Modify the GC algorithm so that the F/W selects the source of GC based on the smallest valid data occupancy rate, instead of the smallest amount of valid data.\n-Modify the firmware to manage the number of internal Reads to Flash Memories as such to not hit the queue depth threshold in this heavy 4KB unaligned Rd/Wr condition.\nEnhancements:\n-N/A"
    },
    {
      "id": "5d8c2335761f5dc729d22a939ccc164e23f6c99632d2615b1482961702fec308",
      "name": "HGST KU45  for model number(s) HUS726020ALS210 and HUS726040ALS210.",
      "version": "KU45",
      "release_id": "68X4C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T17:03:19Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150772M/2/SAS-Drive_Firmware_68X4C_WN64_KU45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=68X4C",
      "size": 11746544,
      "reboot_required": false,
      "description": "This release contains firmware version KU45  for HGST drives. Vendor model numbers HUS726020ALS210 and HUS726040ALS210.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "a32030a01e3562646194421132e1e7f9ddb6972f8de8c79adb5bfb00602da3b6",
      "name": "Samsung PM1645 MU ISE 2.5 SSDR, FW DWF8 for model number(s) MZILT800HAHQ0D3, MZILT1T6HAJQ0D3 and MZILT3T2HALS0D3",
      "version": "DWF8",
      "release_id": "4PPHJ",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:57:29Z",
      "released": "2023-07-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10172294M/2/SAS-Drive_Firmware_4PPHJ_WN64_DWF8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4PPHJ",
      "size": 11922304,
      "reboot_required": false,
      "description": "This release contains firmware version DWF8 for SAMSUNG model number(s) MZILT800HAHQ0D3, MZILT1T6HAJQ0D3 and MZILT3T2HALS0D3",
      "revision_history": "Fixes:\n- Addition of High Capacity drives to common FW version.\n- Addressed Read Timeout errors found during high queue depth / small transfer length.\n- Multiple other minor bug fixes.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "bb82cbf99973004ad4fa46b9d064ac1b23ea7e421990eef9b1994703259e53e1",
      "name": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095",
      "version": "CPE9",
      "release_id": "RRWVT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:56:16Z",
      "released": "2023-09-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10235085M/2/SAS-Drive_Firmware_RRWVT_WN64_CPE9_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RRWVT",
      "size": 12063856,
      "reboot_required": false,
      "description": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095,XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n- Fix drive detection issue.\n\nEnhancements:\n- Enable new DPN for 7.68TB capacity."
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "1422bba58673005e0d8a1f7d9ee1c898c81706f760e54c181b8a463dce6c5e22",
      "name": "Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "version": "BJ07",
      "release_id": "5WMK8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:21:19Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933394M/1/SAS-Drive_Firmware_5WMK8_WN64_BJ07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5WMK8",
      "size": 12038824,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "1fcbe2f15884130068fe5c7cc25584671e6f7044a740a7c5c0d2a66c178bbb28",
      "name": "Kioxia BH07 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "version": "BH07",
      "release_id": "38PHF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:00:20Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933350M/1/SAS-Drive_Firmware_38PHF_WN64_BH07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=38PHF",
      "size": 11958960,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BH07 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "7f3c1816a8abb0d5de05c5772def174d0e1ae5f6c9c2ad5523fd664903346ed8",
      "name": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "version": "CSJA",
      "release_id": "J12RT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-06-30T05:01:47Z",
      "released": "2023-06-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10268173M/1/SAS-Drive_Firmware_J12RT_WN64_CSJA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J12RT",
      "size": 12687840,
      "reboot_required": false,
      "description": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSJ8."
    },
    {
      "id": "d6784baaf602be53256144a13d13ccebfe0dd5110a4cb33a3573fb5e5f7f467f",
      "name": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "version": "CPE6",
      "release_id": "2PY92",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-12-14T07:32:22Z",
      "released": "2022-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09346116M/1/SAS-Drive_Firmware_2PY92_WN64_CPE6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2PY92",
      "size": 12209992,
      "reboot_required": false,
      "description": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n-Initial Release"
    },
    {
      "id": "6b01a365cd3ec211f0220c2550d15f29848832f62579e2e64a7467874c94f2fa",
      "name": "Seagate 4D0C for model number(s) XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "version": "4D0C",
      "release_id": "NX13G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-04-28T10:32:00Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486562M/1/SAS-Drive_Firmware_NX13G_WN64_4D0C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NX13G",
      "size": 11833104,
      "reboot_required": false,
      "description": "This release contains firmware version 4D0C for Seagate drives. Vendor model numbers XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "revision_history": "Fixes:\nFix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can return corrupt data after a power cycle in a corner case.\nFix an issue that can return the sense code 09/80/00 to a WRITE command.\nFix issues that can cause command timeout.\nFix issues that can cause drive assert.\nFix issues that can cause drive hang condition.\nFix an issue that can cause drive-not-ready.\nEnhancements:\nImprove protocol spec compliance.\nImprove throughput performance for specific workloads.\nImprove error logging/sense data reporting."
    },
    {
      "id": "afad81c11ff922969d371d0fc4f99acfa5bc2d5a7b4cd74e2d2c1481ff5f57eb",
      "name": "Seagate KT5C for model number(s) DL900MP0136.",
      "version": "KT5C",
      "release_id": "83FF4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-08-27T08:44:48Z",
      "released": "2021-08-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07688573M/1/SAS-Drive_Firmware_83FF4_WN64_KT5C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=83FF4",
      "size": 11012312,
      "reboot_required": false,
      "description": "This release contains firmware version KT5C for Seagate drives. Vendor model numbers DL900MP0136.",
      "revision_history": "Fixes:\nFix an issue where single SAS port becomes unresponsive\nFix issues that can cause unwarranted SMART warning\nFix issues where assert can result\nFix issues where drive hang condition can result\nFix issues where command timeout can result\nEnhancements:\nImprove performance for certain workloads\nEnhance error logging / sense code reporting accuracy"
    },
    {
      "id": "edef243d8108958192caa385e61442f4dfeee160057a70aae31d7de1ea520510",
      "name": "Seagate KT7B for model number(s) ST900MP0136..",
      "version": "KT7B",
      "release_id": "0V8XY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-08-27T08:28:32Z",
      "released": "2021-08-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07688491M/1/SAS-Drive_Firmware_0V8XY_WN64_KT7B_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0V8XY",
      "size": 11012712,
      "reboot_required": false,
      "description": "This release contains firmware version KT7B for Seagate drives. Vendor model numbers ST900MP0136..",
      "revision_history": "Fixes:\nFix an issue where single SAS port becomes unresponsive\nFix issues that can cause unwarranted SMART warning\nFix issues where assert can result\nFix issues where drive hang condition can result\nFix issues where command timeout can result\nEnhancements:\nImprove performance for certain workloads\nEnhance error logging / sense code reporting accuracy"
    },
    {
      "id": "9f54d16b6a912067843cc2bd8568d7b9c3911cac62f7725298299613a5828fca",
      "name": "Seagate Lange Firmware Version EC16  for model number(s) XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "version": "EC16",
      "release_id": "H3VHX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-02-04T09:29:43Z",
      "released": "2021-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07035193M/1/SAS-Drive_Firmware_H3VHX_WN64_EC16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3VHX",
      "size": 10683112,
      "reboot_required": false,
      "description": "This release contains firmware version EC16 for Seagate drives. Vendor model numbers XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "revision_history": "Fixes:\n-Fix an issue where reading or writing of corrupt data can result after a power cycle\n-Fix an issue which can lead to reduced data retention duration\n-Fix an issue where assert can result when max. queue depth is exceeded\n-Update activity LED blinking behavior to be consistent with Dell requirements\n\nEnhancements:\n-N/A"
    },
    {
      "id": "629d5fb27f74f6eb49ee0f4138a473929570edcca75b5a873ae5090655987a4a",
      "name": "Toshiba EA05 for model number(s) AL14SEB030NY, AL14SEB060NY and AL14SEB120NY.",
      "version": "EA05",
      "release_id": "TGCJ8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-03-27T11:21:24Z",
      "released": "2020-03-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06178570M/1/SAS-Drive_Firmware_TGCJ8_WN64_EA05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TGCJ8",
      "size": 10476472,
      "reboot_required": false,
      "description": "This release contains firmware version EA05 for Toshiba drives. Vendor model numbers AL14SEB030NY, AL14SEB060NY and AL14SEB120NY.",
      "revision_history": "Fixes:\n- Invalid DWORD during Link Reset\n- Apply the Pin11 Specification rev A03\n- 04-4C-91 when drive executes internal reboot\n- Self reboot when 8 commands terminated for TASK SET FULL\n- HDD reports sense 02-04-11 on NOTIFY (Enable Spin Up)\n- Write splice may occur on power loss during ATI\n- HDD hang under specific conditions when Task Set Full\n- HDD hang under specific conditions when TB=1\n- Soft errors in SoC memory\n- Power loss during self test \n- Duplicate sense code sent\n- HDD may hang on hard reset\n\nEnhancements:\n N/A"
    },
    {
      "id": "9cb177ff68cdcacaea5c2e503623fd7a714f7fb1636ab3be4d51aa44fba3c959",
      "name": "Toshiba EB04 for model number(s) AL14SEB18EQY.",
      "version": "EB04",
      "release_id": "NYK8R",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-02-05T05:29:40Z",
      "released": "2020-02-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06078016M/1/SAS-Drive_Firmware_NYK8R_WN64_EB04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NYK8R",
      "size": 10660512,
      "reboot_required": false,
      "description": "This release contains firmware version EB04 for Toshiba drives. Vendor model numbers AL14SEB18EQY..",
      "revision_history": "DOW weight increased to improve protection against signal degradation by ATI"
    },
    {
      "id": "d70e124fd5eb47e2c840087efbaab515361bdd2d7a22418a95246960b9800a43",
      "name": "Samsung DSL8 for model number(s) MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "version": "DSL8",
      "release_id": "PN27G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T20:14:23Z",
      "released": "2018-05-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04994832M/2/SAS-Drive_Firmware_PN27G_WN64_DSL8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PN27G",
      "size": 10407664,
      "reboot_required": false,
      "description": "This release contains firmware version DSL8 for Samsung drives. Vendor model numbers MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "revision_history": "Fixes\n-n/a\n\nEnhancements\n-n/a"
    },
    {
      "id": "c167a624468a834e419f2e7acf82c5cc2654cbe751c39da1c3c9ecfb54e0cfaa",
      "name": "Seagate NT72 for model number(s) ST2000NX0373.",
      "version": "NT72",
      "release_id": "WN08D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T19:37:16Z",
      "released": "2018-12-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05384185M/4/SAS-Drive_Firmware_WN08D_WN64_NT72_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WN08D",
      "size": 10530576,
      "reboot_required": false,
      "description": "This release contains firmware version NT72 for SUPPLIER model number(s) ST2000NX0373  Capacity of 2TB.",
      "revision_history": "fixes:\n-improve compatibility with Linux OS after Sanitize Cryptographic Erase was performed\n-Fix issues where Command Timeout can result\n-Fix issues where Assert can result\n-Fix an issue where drive hang can result\n-Fix an issue where Current Mode Page values revert to Default values after power cycle\n\nenhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "88ef2ad755dec9529576ce569e05f5a033b45bea9543d042ea19072fdac81401",
      "name": "Toshiba AX0B for model number(s) PX05SVQ192B, PX05SVQ384B and PX05SVQ096B.",
      "version": "AX0B",
      "release_id": "6CKWM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-05-05T04:34:33Z",
      "released": "2019-05-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05601856M/1/SAS-Drive_Firmware_6CKWM_WN64_AX0B_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6CKWM",
      "size": 10865384,
      "reboot_required": false,
      "description": "This release contains firmware version AX0B for Toshiba drives. Vendor model numbers PX05SVQ192B, PX05SVQ384B and PX05SVQ096B.",
      "revision_history": "Fixes:\n- Modify the Wear Leveling algorithm so that the F/W searches deeper into free super block pool. The depth for search depends on the drive capacity.\n- Modify the GC algorithm so that the F/W selects the source of GC based on the smallest valid data occupancy rate, instead of the smallest amount of valid data.\n-Modify the firmware to manage the number of internal Reads to Flash Memories as such to not hit the queue depth threshold in this heavy 4KB unaligned Rd/Wr condition.\nEnhancements:\n-N/A"
    },
    {
      "id": "06e6fa1d3e0650bdf356b4d03849c30c13263e8e3565403075dfdeb7a65f1a3e",
      "name": "Seagate BS05 for HDD ON 2.5 SAS12 15K 512e drive model number ST600MM0238 and ST300MM0078.",
      "version": "BS05",
      "release_id": "2R4CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-02-15T05:59:39Z",
      "released": "2019-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05461025M/1/SAS-Drive_Firmware_2R4CX_WN64_BS05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2R4CX",
      "size": 10737736,
      "reboot_required": false,
      "description": "This release contains firmware version BS05 for Seagate HDD Thunderbug 2.5 SAS12 10K 512n drive. Vendor model numbers: ST600MM0238 and ST300MM0078",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Current Mode Page values reverted to Default values after Power Cycle     \n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\n-Fix issues where command timeout can result\n-Fix issues where IOEDC error can result\n\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "2b640a1d6164bd5474c4daf2317c4d1e2048836e0608b4b0a3b0caa51e708a90",
      "name": "Seagate NT32 for model number(s) ST2000NX0463 and ST1000NX0473.",
      "version": "NT32",
      "release_id": "GW3V7",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T09:37:37Z",
      "released": "2018-08-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05151883M/2/SAS-Drive_Firmware_GW3V7_WN64_NT32_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GW3V7",
      "size": 10436112,
      "reboot_required": false,
      "description": "This release contains firmware version NT31 for Seagate drives. Vendor model numbers ST2000NX0463 and ST1000NX0473.",
      "revision_history": "Fixes\n- Enable Cache Management Resource Overflow Prevention to resolve command timout\n- Current Mode Page values reverted to Default values after Power Cycle\n- Drive fails to protect the sector if EPOW arrives during write retries\n- Command timeouts after Sanitize Command is executed\n- DEFT fails segment unexpectedly when interrupted\n- Drive Self-Test Read Scan Stuck\n- Pad LOD Files To 4K Boundary for Dell SAS\n- Unexpected power mode transition during Background Extended DST causing assert\n- Assert after Task Management Function aborted by Hard Reset\n- Various asserts reported during Active Immediate command\n- Modify Sanitize Crypto Erase behavior to write zeros to OD and ID\n- Turn on the PS bit for mode page 19 subpages\n- Assert on Sequential Write When First Write is Sending Status\n- Enable Support for Active DIC feature on DELL MC and BC configurations\n- Update DST subtest to improve handling of commands that interrupt DST.\n- Drive reported false tag overlap error 0B/4E/00/01\n- Drive did not reject Default DST command while DEFT in progress\n- Drive Assert during Band Delete/Create with concurrent I/O\n- Data abort on channel hardware access after PLL loss-of-lock\n\nEnhancements\nn/a"
    },
    {
      "id": "f49726ba768d5d95b721f736aaafd02baf4adad22a0ee2d5cec7de1ae8665a32",
      "name": "Seagate TSC9 for model number(s) ST1200MM0108..",
      "version": "TSC9",
      "release_id": "8RN2D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T08:09:35Z",
      "released": "2018-01-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04756109M/2/SAS-Drive_Firmware_8RN2D_WN64_TSC9_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8RN2D",
      "size": 10483456,
      "reboot_required": false,
      "description": "This release contains firmware version TSC9 for Seagate drives. Vendor model numbers ST1200MM0108..",
      "revision_history": "Fixes:\n'-Fix an issue where access to drive is erroneously denied during drive self test\n-Fix an issue where Offline Extended DST is reported in progress status indefinitely\n-Fix issues where assert condition can result\n-Fix issues where command timeout can result\n-Fix an issue where incorrect value can be reported in Saved Mode Pages\n\nEnhancements:\n- N/A"
    },
    {
      "id": "4695419d23bdd78166088b177010e8fe91d8488323b8fe526201c4f263dd0af5",
      "name": "Toshiba EC02 for model number(s) AL13SXB30ENY and AL13SXB60ENY.",
      "version": "EC02",
      "release_id": "47FXP",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-27T18:19:16Z",
      "released": "2017-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04337050M/3/SAS-Drive_Firmware_47FXP_WN64_EC02_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=47FXP",
      "size": 9662008,
      "reboot_required": false,
      "description": "This release contains firmware version EC02 for Toshiba drives. Vendor model numbers AL13SXB30ENY and AL13SXB60ENY.",
      "revision_history": "Fixes:\n-Firmware fix for TASK SET FULL bug during multiport usage.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "04ec308a99971de5cff5f462337b720c363907e5555189bb9cfd4a864710fd66",
      "name": "Seagate NSF2 for model number(s) ST2000NX0453..",
      "version": "NSF2",
      "release_id": "1HWVN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-21T08:24:58Z",
      "released": "2019-01-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05424349M/1/SAS-Drive_Firmware_1HWVN_WN64_NSF2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1HWVN",
      "size": 10649408,
      "reboot_required": false,
      "description": "This release contains firmware version NSF2 for Seagate drives. Vendor model numbers ST2000NX0453..",
      "revision_history": "Fixes\n-improve compatibility with Linux OS after Sanitize Cryptographic Erase was performed\n-Fix issues where Command Timeout can result\n-Fix issues where Assert can result\n-Fix an issue where drive hang can result\n-Fix an issue where IOEDC error can result\n-Fix an issue where Current Mode Page values revert to Default values after power cycle\n\nEnhancements\n-Improve performance for specific workload cases\n-Improve status/reporting accuracy"
    },
    {
      "id": "4fbfe9a6dad569fce77de63403d506f7eadd69d383980ede0b527ff7b27c4f17",
      "name": "Seagate 2T51 for model number(s) ST1800MM0198..",
      "version": "2T51",
      "release_id": "5YH6J",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-02-17T21:55:39Z",
      "released": "2017-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04190540M/1/SAS-Drive_Firmware_5YH6J_WN64_2T51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5YH6J",
      "size": 17138992,
      "reboot_required": false,
      "description": "This release contains firmware version 2T51 for Seagate drives. Vendor model numbers ST1800MM0198..",
      "revision_history": "Initial release"
    },
    {
      "id": "a4a85d64c2a0d119932848e41a3b06019d8b8062c1169f30f894f9b6d78a5cdf",
      "name": "Seagate UT71 for model number(s) ST1200MM0198..",
      "version": "UT71",
      "release_id": "W7K02",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-02-17T21:25:50Z",
      "released": "2017-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04190452M/1/SAS-Drive_Firmware_W7K02_WN64_UT71_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=W7K02",
      "size": 17010400,
      "reboot_required": false,
      "description": "This release contains firmware version UT71 for Seagate drives. Vendor model numbers ST1200MM0198..",
      "revision_history": "Initial release"
    }
  ]
}