{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "m7725",
  "name": "M7725",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge M7725 Updates",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 5,
      "rss": "/m7725/urgent/rss.xml",
      "api": "/api/m7725/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 14,
      "rss": "/m7725/recommended/rss.xml",
      "api": "/api/m7725/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 18,
      "rss": "/m7725/optional/rss.xml",
      "api": "/api/m7725/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/m7725/bios/rss.xml",
      "api": "/api/m7725/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 1,
      "rss": "/m7725/boss/rss.xml",
      "api": "/api/m7725/boss"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/m7725/diagnostics/rss.xml",
      "api": "/api/m7725/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/m7725/drivers-for-os-deployment/rss.xml",
      "api": "/api/m7725/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 13,
      "rss": "/m7725/express-flash-pcie-ssd/rss.xml",
      "api": "/api/m7725/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/m7725/firmware/rss.xml",
      "api": "/api/m7725/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/m7725/idrac/rss.xml",
      "api": "/api/m7725/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 12,
      "rss": "/m7725/network/rss.xml",
      "api": "/api/m7725/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 2,
      "rss": "/m7725/sas-drive/rss.xml",
      "api": "/api/m7725/sas-drive"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 3,
      "rss": "/m7725/serial-ata/rss.xml",
      "api": "/api/m7725/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 1,
      "rss": "/m7725/systems-management/rss.xml",
      "api": "/api/m7725/systems-management"
    }
  ],
  "count": 37,
  "updates": [
    {
      "id": "499fc3654d44cef7955f64ba3684835dc91cada20a921c2b19b0e6282f5cdff4",
      "name": "Dell Server PowerEdge R7725/R6725/R7725xd/M7725/XE7745/XE9785/XE9785L BIOS Version 1.9.5",
      "version": "1.9.5",
      "release_id": "JW14F",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-11-11T06:21:07Z",
      "released": "2026-11-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15225275M/1/BIOS_JW14F_WN64_1.9.5.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JW14F",
      "size": 41529344,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced features sections",
      "revision_history": "Fixes:\n- Fixed an issue where multiple correctable PCIe errors were reported on GPU devices under heavy workload.\n- Fixed an issue where a kernel panic occurred when installing Ubuntu 26.04 on systems with a Compute Express Link (CXL) memory configuration.\n- Fixed an issue where systems with 128 GB of total installed memory failed to boot into Linux when Secure Memory Encryption, Secure Nested Paging, and SNP Memory Coverage were all enabled.\n- Fixed a truncation issue affecting the Maximum Password Age value set through iDRAC interfaces\n\nEnhancements:\n- The AMD Generic Encapsulated Software Architecture (AGESA) Interface Specification for Family 1Ah Models 00h-0Fh has been upgraded to version 1.0.0.B Patch 3.\n- Improved the HTTPS boot messages.\n- This product release contains security update. Any security fix information will be accessible on the Dell Security Advisories and Notices website."
    },
    {
      "id": "837f52bcdf77c2d14310498f7dd4952e13c37aa4c6fdc01265b9a428e061657d",
      "name": "Dell EMC iDRAC Service Module Installer for OS DUP, v6.2.0.0",
      "version": "6.2.0.0",
      "release_id": "JDJH3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-11-09T07:17:23Z",
      "released": "2026-10-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15095008M/5/Systems-Management_Application_JDJH3_WN64_6.2.0.0_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JDJH3",
      "size": 34422592,
      "reboot_required": false,
      "description": "iDRAC Service Module (iSM) is a lightweight software service that better integrates operating system (OS) features with iDRAC and can be installed on Dell PowerEdge 15G and above servers. iSM provides OS-related information to iDRAC and adds capabilities such as Lifecycle Controller log event replication into the OS log, iDRAC SNMP alerts via OS, iDRAC hard reset and remote full Power Cycle. iSM has very little impact on the host processor and smaller memory footprint, thus expanding iDRAC management to the supported host operating systems.",
      "revision_history": "NA"
    },
    {
      "id": "0977dfbae8a40a6e966730b9138c338cd5e985d9f63aa6ac5dd14dcf8700cee4",
      "name": "iDRAC 1.30.65.51",
      "version": "1.30.65.51",
      "release_id": "C21YH",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-11-06T13:39:20Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213660M/1/iDRAC-with-Lifecycle-Controller_Firmware_C21YH_WN64_1.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C21YH",
      "size": 357946640,
      "reboot_required": false,
      "description": "iDRAC 1.30.65.51",
      "revision_history": "Fixes\n- Fixed the issue where Serbia was missing from the country code list in the iDRAC SSL/TLS CSR interface.\n- Fixed the issue where iDRAC 1.30.40.51 returns HTTP 400 when accessing Web GUI via FQDN despite HostHeaderCheck being disabled.\n- Fixed the issue where iDRAC time never reverts to RTC if NTP is unavailable.\n- Fixed the issue where SWC9048 error message appears when trying to launch iDRAC IP from UI after updating iDRAC firmware with FIPS enabled.\n- Fixed the issue where SystemCurrentCapLimit and SystemCurrentCapSetting options were missing in racadm get/set system.ServerPwr output while GridCurrentCapLimit settings were exposed.\n- Fixed the issue where STOR090 error occurred when failing to import OMEnt template and SCP when Dedicated HotSpare is present on PERC H965i.\n- Fixed the issue where iDRAC10 SCP export command fails via RACADM for iDRAC firmware version 1.30.40.51.\n- Fixed the issue where GPU Temperature Probe Readings were missing in SNMP and ProbeStatus appeared in unknown state after upgrading to iDRAC 1.30.40.51.\n- Fixed the issue where fans were spinning at 100% when system idle on PowerEdge XE9785 with AMD Pensando Pollara 400 AI Network Interface Card (NIC).\n\n\nEnhancements:\n- Added filter options in iDRAC for SAS address.\n- Fixed the issue where banner for functional pages was still observed when system is in lockdown mode.\n- Added Redfish support to delete AD/LDAP certificates.\n- Populated Redfish Volume Identifiers with durable identifier for PERC RAID virtual disks.\n- Added support to Redfish action EventService.SubmitTestEvent to send test events to Server-Sent Events.\n- Added Redfish support to retrieve configuration preview results for a Job ID.\n- Added Redfish support to reset Storage Controller to defaults.\n- Updated battery page and rollup status design.\n- Added the ability to mount virtual images from S3 for iDRAC.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification.\n- Improved Redfish error messaging for BootSourceOverride failure in iDRAC10.\n- Added OpenID Connect with Azure Entra ID support.\n- Added low privilege iDRAC Operator role.\n- Enabled email alerts for thermal-related GPU/TMP events.\n- Added SMTP modern authentication (OAuth2) support.\n- Enabled email alerts for critical PCI errors (PCI3039/PCI3040) in iDRAC10.\n- Added iDRAC10 BIOS Console Log Retention for serviceability.\n- Added block-level erase and cryptographic validation for iDRAC partitions in SystemErase.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero-Touch Bootstrap.\n- Added support for SID/OPAL/PSID drive status property.\n- Enabled Full APO (Automatic Power On) support for FullPowerReset.\n- Added fan board page health rollup into overall system health.\n- Fixed iDRAC delay in MEM message logging that caused incorrect event ordering.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message.\n- Aligned MultipartUpload ApplyTime behavior with SimpleUpdate (OnStartUpdateRequest).\n- Added BIN Catalog update support.\n- Added native iDRAC10 support for Open Telemetry (OTEL) metric streaming.\n- Added Component-Level Firmware Update and Discoverability via Redfish.\n- Added support for custom HTTP ports for InstallFromRepository via iDRAC UI, Redfish, and RACADM.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior.\n- Added iDRAC support for controlling the SMA_OUT source select.\n- Added support in iDRAC to control the timing module Write_en pin and timing module reset pin with host control via Redfish.\n- Enabled PSU firmware update when single PSU is installed.\n- Added iDRAC CMP V2 support on PowerEdge XR8720T.\n- Added iDRAC uptime to sysinfo.\n- Enhanced iDRAC10 UI usability with VLAN placement, search/filter"
    },
    {
      "id": "3c42a5d5d6593d1bb6afbb03bfc0943458d93671a8a9b79d91ec42193d56871e",
      "name": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "GF3PY",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-11-03T17:31:07Z",
      "released": "2026-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15199882M/1/Express-Flash-PCIe-SSD_Firmware_GF3PY_WN64_1.5.0_A05.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GF3PY",
      "size": 38306408,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10x0 ISE PCIe SSD Firmware Release"
    },
    {
      "id": "69a58ee638d7dd383229f7edeb9f9319c1937db810aeee75697ddd20288506cc",
      "name": "NVIDIA Mellanox Windows 64-bit Server OS Drivers for Mellanox ConnectX-4 LX, ConnectX-5, ConnectX-6 and ConnectX-7, ConnectX-8 Adapters",
      "version": "25.010.100",
      "release_id": "054K7",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2026-11-02T07:42:07Z",
      "released": "2026-08-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14932497M/2/Network_Driver_054K7_WN64_25.010.100_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=054K7",
      "size": 322683056,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, and ConnectX-7, ConnectX-8 NIC drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "1121dc0cd78765c8b1a64cd2db76ed7a213efc989c6a57f01827179a7b5bbb5a",
      "name": "NVIDIA Mellanox Firmware Release 40.46.3048 for the Industry-Standard NVIDIA Mellanox ConnectX-8 XDR Adapters",
      "version": "40.46.3048",
      "release_id": "T7C7X",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-30T21:27:08Z",
      "released": "2025-10-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13710964M/5/Network_Firmware_T7C7X_WN64_40.46.3048_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T7C7X",
      "size": 64871360,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 40.46.3048 on the industry-standard NVIDIA Mellanox  ConnectX-8 XDR adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "Please refer to the attached release notes for fixes and enhancements."
    },
    {
      "id": "5bbdae55feec05548f25c7f818060529f1a3e4aef24e5c08c863d804cdce751d",
      "name": "Broadcom 5741X, 57502, 57608 Network Device Firmware (Industry) 23.8.1",
      "version": "238.1.191.0",
      "release_id": "MJFY0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-10-15T21:13:46Z",
      "released": "2026-10-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15134026M/1/Network_Firmware_MJFY0_WN64_238.1.191.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MJFY0",
      "size": 68102160,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for the Broadcom NetXtreme-E devices.   This release should be used with the Broadcom NetXtreme-E 23.8 device drivers. Note: This firmware may require a cold reboot after installation.",
      "revision_history": "Fixes:\n- BCM57414 2x25G OCP partition link status is reported as \"unknown\" by iDRAC.\n- PCIe PTM enabled on 5750x/57608 without verifying upstream device PTM state.\n- AI-assisted code improvements.\n\nEnhancements:\n- Add support for Ubuntu 26.04. \n- Add support for RHEL 9.7, 9.8, 10.1, and 10.2.\n- Add support for rebootless firmware activation.\n- Add support for configuration attributes including Virtual MAC address"
    },
    {
      "id": "eeabb26543e42cb0c06dfa7c810aad0eefba853a9ed84fcf5a217cf1cf793607",
      "name": "NVIDIA Mellanox Firmware Release 28.50.1002 for the Industry-Standard NVIDIA Mellanox ConnectX-7 NDR Adapters",
      "version": "28.50.1002",
      "release_id": "GC3NG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-10-02T22:05:47Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15088418M/1/Network_Firmware_GC3NG_WN64_28.50.1002_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GC3NG",
      "size": 76977584,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 28.50.1002 on the industry-standard NVIDIA Mellanox ConnectX-7 NDR OSFP adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "55fdb9edfa7c9812935543decb2ff483697791b2d6eb1753f8ee91ce4aadeb79",
      "name": "NVIDIA Mellanox Firmware Release 26.50.1002 for the Industry-Standard NVIDIA Mellanox ConnectX-6 LX Ethernet Adapters",
      "version": "26.50.1002",
      "release_id": "X3HC5",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T20:46:03Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15081191M/1/Network_Firmware_X3HC5_WN64_26.50.1002_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X3HC5",
      "size": 45924000,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 26.50.1002 on the industry-standard NVIDIA Mellanox ConnectX-6 LX adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "6aaa2310a0ed6f11b7f9b8ff4e667872695e945ef6dccd1bac1983b8ca2a9cc6",
      "name": "NVIDIA Mellanox Firmware Release 22.50.1002 for the Industry-Standard NVIDIA Mellanox ConnectX-6 DX Ethernet Adapters",
      "version": "22.50.1002",
      "release_id": "D4HHF",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-09-30T15:36:43Z",
      "released": "2026-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15080448M/1/Network_Firmware_D4HHF_WN64_22.50.1002_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D4HHF",
      "size": 46441984,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox firmware release 22.50.1002 on the industry-standard NVIDIA Mellanox ConnectX-6 DX adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "61aa072fa29c265fba04bfc1d6f2e6ccc306cc141882c41aa143d899f00c9928",
      "name": "NVIDIA Mellanox Windows 64-bit Server OS Drivers for Mellanox ConnectX-4 LX, ConnectX-5, ConnectX-6, ConnectX-7, ConnectX-8 and ConnectX-9 Adapters",
      "version": "26.007.01",
      "release_id": "0PT26",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-09-29T19:07:51Z",
      "released": "2026-09-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15074840M/1/Network_Driver_0PT26_WN64_26.007.01_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0PT26",
      "size": 395045064,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install NVIDIA Mellanox ConnectX-4 Lx, ConnectX-5 Ex, ConnectX-6, ConnectX-7, ConnectX-8 and ConnectX-9 NIC drivers on Windows Server 2022 and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update."
    },
    {
      "id": "3ebbb8f7345098e33d862cd3ed2f9754fd075b6183dd0045b708cb42fe305998",
      "name": "Hynix 1.3.1 FW for PE90X0 NVMe ISE drive program for model number HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N",
      "version": "1.3.1",
      "release_id": "YJG7C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-09-15T05:20:56Z",
      "released": "2025-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13708213M/2/Express-Flash-PCIe-SSD_Firmware_YJG7C_WN64_1.3.1_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YJG7C",
      "size": 28468000,
      "reboot_required": true,
      "description": "Hynix 1.3.1. FW for PE90X0 NVMe ISE drive program for model numbers HFS480GEJ8X167N, HFS800GEJ8X167N, HFS960GEJ8X167N, HFS1T9GEJ8X167N.HFS1T9GEJ8X167N.",
      "revision_history": "Fix: \n\n- FW fixes issues behind Interposer and with SDPM."
    },
    {
      "id": "b31af8d25442f47d287b9165621c02201f15b930f033645f7c931dba1ce3dae7",
      "name": "Dell OS Driver Pack",
      "version": "26.08.02",
      "release_id": "5XVNX",
      "category": "Drivers for OS Deployment",
      "category_slug": "drivers-for-os-deployment",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-08-17T06:37:41Z",
      "released": "2026-08-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14907780M/1/Drivers-for-OS-Deployment_Application_5XVNX_WN64_26.08.02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5XVNX",
      "size": 52811920,
      "reboot_required": false,
      "description": "OS Driver Pack for PowerEdge 17G servers. This Driver Pack contains applicable storage, Drivers for OCP cards and chipset drivers to support OS installation using the Dell Lifecycle Controller",
      "revision_history": "N/A"
    },
    {
      "id": "10672d2ab31a63d746e4248394081f82de0310aaa1faf5e4c38a5ecc63db8f5e",
      "name": "Broadcom 57608 Network Device Firmware (Dell) 23.8",
      "version": "38.11.70.00",
      "release_id": "D64KH",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-30T17:47:40Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843647M/2/Network_Firmware_D64KH_WN64_38.11.70.00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D64KH",
      "size": 23555464,
      "reboot_required": false,
      "description": "This release provides updated network controller firmware for the Broadcom NetXtreme-E devices.   This release should be used with the Broadcom NetXtreme-E 23.8 device drivers.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "e383c232a59d867730c67aff93fece1f8bb4e33d1f8f1d0795276821d80c6740",
      "name": "Broadcom Windows 64bit driver update for NetXtreme-E Ethernet adapters for the 23.8 update.",
      "version": "38.11.70.00",
      "release_id": "X9DJG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-30T17:44:02Z",
      "released": "2026-07-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14843656M/2/Network_Driver_X9DJG_WN64_38.11.70.00_238.1.170.0_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9DJG",
      "size": 17265544,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme-E Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- \n\nEnhancements:\n-"
    },
    {
      "id": "4d3ed52177faa94e183a6c75e4cee8e3175a89321e6590c16562a9acd2cbb45b",
      "name": "Intel NIC Drivers, Release Version 31.2, for Windows 64-bit Operating Systems",
      "version": "31.2",
      "release_id": "TDVN6",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-07-23T14:09:08Z",
      "released": "2026-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14817155M/1/Network_Driver_TDVN6_WN64_31.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TDVN6",
      "size": 22841272,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel (R) NIC Drivers on Windows Server 2022, and Windows Server 2025. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "See readme.txt and release notes for more information."
    },
    {
      "id": "bec783224af57063f49484de0cde7d424b3809ef473f1b1cd3002b35c9429484",
      "name": "Intel NIC Firmware Update Package release 31.2 for Intel E610-based Adapters",
      "version": "31.2.0.3",
      "release_id": "D2PJV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-23T14:02:23Z",
      "released": "2026-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14817111M/1/Network_Firmware_D2PJV_WN64_31.2.0.3_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D2PJV",
      "size": 35417392,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel (R) NIC firmware on Intel (R) E610-based adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "See release notes file for more information."
    },
    {
      "id": "4e263745edf43130b0f93dd2ab8d1b2b55532e78874d690ca1762e663eefdb30",
      "name": "Intel NIC Firmware Release 31.2 for Intel E835 Adapters",
      "version": "31.2.0.3",
      "release_id": "FXWH4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-23T13:37:40Z",
      "released": "2026-07-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14817010M/1/Network_Firmware_FXWH4_WN64_31.2.0.3_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FXWH4",
      "size": 54722688,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Release 31.2 on Intel E835 Adapters",
      "revision_history": "See release notes file for more information"
    },
    {
      "id": "492049c71238d8dc5085ef752d7dcd9406905f904a0c918da2e6cc862de1b52e",
      "name": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release",
      "version": "1.1.0",
      "release_id": "5DFM6",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-14T16:13:13Z",
      "released": "2026-07-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14775033M/1/Express-Flash-PCIe-SSD_Firmware_5DFM6_WN64_1.1.0_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5DFM6",
      "size": 38571336,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PS10X0 E3.S ISE PCIe SSD Firmware Release"
    },
    {
      "id": "7cd17db5182581a2ca4292a1bd1ac4ec2b81e01a3f9e0eebb710ac61b5577aab",
      "name": "Dell EMC PowerEdge Express Flash NVMe AGN RI E3s Gen5 Maintenance Firmware Release",
      "version": "1.3.0",
      "release_id": "HN6NV",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-07-11T13:52:58Z",
      "released": "2026-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14763918M/1/Express-Flash-PCIe-SSD_Firmware_HN6NV_WN64_1.3.0_A07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HN6NV",
      "size": 35704848,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash NVMe AGN RI E3s Gen5 Maintenance Firmware Release",
      "revision_history": "PLACEHOLDER\n\nNOTE: FIRMWARE 1.2.1 IS LOCKED - NO DOWN-REV POSSIBLE AFTER UPGRADE."
    },
    {
      "id": "1649cedd050f14c96f8903133c79a26b7f90719920c7fbde0a1ff66c7d8db1b9",
      "name": "Firmware update for WDC Paris-CP SATA ISE Model Numbers: WUH722012CLE600, WUH722016CLE600",
      "version": "AT06",
      "release_id": "36JH0",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T07:23:32Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14472919M/1/Serial-ATA_Firmware_36JH0_WN64_AT06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=36JH0",
      "size": 22781784,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP AT06 FW SATA ISE Model Numbers: WUH722012CLE600, WUH722016CLE600.",
      "revision_history": "- Firmware update to ensure the 512e Dell Model string and Dell Device ID will not show correctly when Server code is loaded over Storage code.\n- FW fix to ensure Background Media Scan timer is reset correctly when Offline Data Collection is started.\n- Code updated to ensure Component ID and Model string will report correctly after firmware upload."
    },
    {
      "id": "14646318eed9bac1cd8e2b6564c5b3f136a7e60b8437700c0a1d1dfa05775f75",
      "name": "Firmware update for WDC Paris-CP SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200",
      "version": "AS06",
      "release_id": "XTC10",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-24T06:13:54Z",
      "released": "2026-04-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14472580M/1/SAS-Drive_Firmware_XTC10_WN64_AS06_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XTC10",
      "size": 22713344,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP  AS06 FW SAS ISE Model Numbers: WUH722012CL5200, WUH722016CL5200.",
      "revision_history": "- Firmware update to ensure the 512e Dell Model string and Dell Device ID will not show correctly when Server code is loaded over Storage code.\n- FW fix to ensure Background Media Scan timer is reset correctly when Offline Data Collection is started.\n- Code updated to ensure Component ID and Model string will report correctly after firmware upload."
    },
    {
      "id": "e18b20205b02af263bfcc61c713927996808cb3d9723d0b879d70a4729b28f62",
      "name": "BOSS-N1 Modular DC-MHS Firmware",
      "version": "2.2.13.2038",
      "release_id": "MVVC8",
      "category": "BOSS",
      "category_slug": "boss",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-04-14T11:11:46Z",
      "released": "2026-04-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14425811M/3/BOSS_Firmware_MVVC8_WN64_2.2.13.2038_A03_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MVVC8",
      "size": 23307736,
      "reboot_required": true,
      "description": "BOSS-N1 Modular DC-MHS Package Version 2.2.13.2038"
    },
    {
      "id": "9908629a3c6dc68fa7bd50152775a1b55d88d11e66dbd615cc0ee12ee6f32e5c",
      "name": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "version": "1.0.0",
      "release_id": "HJ15N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-04-07T10:29:04Z",
      "released": "2025-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14393389M/1/Express-Flash-PCIe-SSD_Firmware_HJ15N_WN64_1.0.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HJ15N",
      "size": 28267144,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM9 ISE Firmware Release",
      "revision_history": "Fixes:\nN/A - Initial Release\n\nEnhancements:\nN/A - Initial Release"
    },
    {
      "id": "832f358867a87dbab42fc379e286da1d8bd7b8fd87d614862be22df1da90058d",
      "name": "Hynix SE5130 DG02 Firmware for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N",
      "version": "DG02",
      "release_id": "17C3M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-03-09T14:43:52Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14279570M/1/Serial-ATA_Firmware_17C3M_WN64_DG02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17C3M",
      "size": 25675424,
      "reboot_required": true,
      "description": "This is the initial firmware release of HYNIX, SE5130, DG02 for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N.",
      "revision_history": "Fixes:\n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "a3ef6f84b07b203d1e1cd1f2b406481ced74ecd276dc0b9a069622e1f2784499",
      "name": "Passive Backplane Firmware for 17th Generation PowerEdge 1U Servers",
      "version": "1.92",
      "release_id": "0M4TD",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-01-21T05:13:52Z",
      "released": "2025-11-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13878591M/2/Firmware_0M4TD_WN64_1.92_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0M4TD",
      "size": 20027320,
      "reboot_required": false,
      "description": "Passive Backplane Firmware for 17th Generation PowerEdge 1U Servers",
      "revision_history": "Firmware 1.92\n\nFixes - Increased i2c signal strength\n\nFirmware 1.90\n\nFixes:  Added additional margin to an I2C signal"
    },
    {
      "id": "58e394bb0219f32769b3c7c4911b1e094710048d3d16d092fe19ba0c8ded1e36",
      "name": "Dell 64 Bit uEFI Diagnostics, version 4303",
      "version": "4303A52",
      "release_id": "94KRT",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-01-14T21:20:10Z",
      "released": "2025-11-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14086682M/1/Diagnostics_Application_94KRT_WN64_4303A52_4303.52.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=94KRT",
      "size": 19092400,
      "reboot_required": false,
      "description": "Dell Diagnostics is designed to verify the proper operation of the hardware installed in your system outside of a high-level operating system environment. The files in this group can be used to update these diagnostics on a system with a Lifecycle Controller.",
      "revision_history": "This release contains minor bug fixes and enhancements."
    },
    {
      "id": "30ad8ee9b868ed58051f9fcf99c4067e24ac3d2af9e5559ce2b034dae5e200c5",
      "name": "Dell Express Flash NVMe PE1010 E3.S ISE PCIe SSD Firmware Release",
      "version": "1.1.0",
      "release_id": "0930W",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-12-16T16:22:16Z",
      "released": "2025-12-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13990053M/1/Express-Flash-PCIe-SSD_Firmware_0930W_WN64_1.1.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0930W",
      "size": 32600104,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PE1010 E3.S ISE PCIe SSD Firmware Release"
    },
    {
      "id": "c73beccb3d67ad1b365735cea9aefae76310134df79570616d77bd8f290f431d",
      "name": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205",
      "version": "AM05",
      "release_id": "HTW37",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T10:16:13Z",
      "released": "2025-11-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13893761M/1/SAS-Drive_Firmware_HTW37_WN64_AM05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HTW37",
      "size": 25081440,
      "reboot_required": false,
      "description": "Firmware update for WDC Paris-CP SAS FIPS Model Number: WUH722016CL5205.\nCode updated to fix potential issue during Dell Factory Test.",
      "revision_history": "Firmware update to address potential issue during Dell Enhanced Factory Test."
    },
    {
      "id": "dbdfbff4fda3b33a0f47c4f2c9593f17f3ce0e05b9698b3ff06a66b44465d1ae",
      "name": "Hynix SE5110 ISE RI DZ04 Firmware for model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N",
      "version": "DZ04",
      "release_id": "HFTMG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-11-12T10:51:19Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13855285M/1/Serial-ATA_Firmware_HFTMG_WN64_DZ04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HFTMG",
      "size": 26870384,
      "reboot_required": true,
      "description": "This release contains initial firmware DZ04 for Hynix SE5110 ISE. Model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N.",
      "revision_history": "Fixes: \n\nFix1: Add a sequence to clear the \"\"health monitoring done bit\"\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while."
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "7ca27dc0f4b8ab53ef9a20e4eed7b08d3586931692baa0e1ac683070931385e1",
      "name": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "version": "2.0.4",
      "release_id": "50PDK",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-04T17:58:25Z",
      "released": "2025-05-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13198272M/1/Express-Flash-PCIe-SSD_Firmware_50PDK_WN64_2.0.4_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=50PDK",
      "size": 29801952,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD8P E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. When the reference clock is turned off after a PERET# assertion interrupt or a reference clock off interrupt, the CPU never accesses the MAC register until the PIPE clock is restored after PERST# de-assertion.\n2. PHY reset during Hot Reset or Link Disabled is not mandatory, so this process can be skipped. This measure shortens the transition time from Detect to Polling.Active from 70 ms to about 10 ms.\n3. Added flag to prevent DRAM Self Refresh from being triggered.\n4. Once a specific Block has been marked as a bad block that is not to be used, an erase error on the bad block will not cause the Block Erase operation to fail.\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "1c33160daccea25862c0868752c3f6de3029d3fbed1f0c2ff3803d0ef3b0753d",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 E3.S FIPS Firmware Maintenance Release",
      "version": "3.0.2",
      "release_id": "VN92N",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-23T17:03:52Z",
      "released": "2025-04-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13157817M/1/Express-Flash-PCIe-SSD_Firmware_VN92N_WN64_3.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VN92N",
      "size": 29958320,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 E3.S FIPS Firmware Maintenance Release",
      "revision_history": "Fixes:  \nTo be Added."
    },
    {
      "id": "e1c9baab746a197329509da4e36ba1d2db44f75dc2a71e34e37910ece96bb56b",
      "name": "Dell Express Flash NVMe PCIe SSD CM7 E3.S ISE Firmware Maintenance Release",
      "version": "2.0.2",
      "release_id": "N43V2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-23T17:03:30Z",
      "released": "2025-04-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13157812M/1/Express-Flash-PCIe-SSD_Firmware_N43V2_WN64_2.0.2_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N43V2",
      "size": 29819040,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM7 E3.S ISE Firmware Maintenance Release",
      "revision_history": "Fixes:  \nTo be added\n\nEnhancements:  \nTo Be added"
    },
    {
      "id": "6afe093e100584c1939aa6464f00d6bc0518318675009d522eb2afad6b7ad7c5",
      "name": "Dell Express Flash NVMe PCIe SSD 9550 E3.S ISE Firmware Release",
      "version": "1.0.2",
      "release_id": "5GTC9",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-03-13T00:42:16Z",
      "released": "2025-03-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12850492M/1/Express-Flash-PCIe-SSD_Firmware_5GTC9_WN64_1.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5GTC9",
      "size": 30929456,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD 9550 E3.S ISE Firmware Release",
      "revision_history": "Known Limitations:\nFirmware update using DUPs will fail from any RHEL and Ubuntu OS. Either use Windows SLES or iDRAC for FW update - Initial release\n\nFixes:  \nN/A - Initial release\n\nEnhancements:  \nN/A - Initial release"
    },
    {
      "id": "7be90932a9eca915194db12b4b54c6e2d1dfaf50ecc4c79c27b1761682ea45d0",
      "name": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "version": "2.5.0",
      "release_id": "4P5K1",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-07-03T13:05:39Z",
      "released": "2024-07-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11804735M/1/Express-Flash-PCIe-SSD_Firmware_4P5K1_WN64_2.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4P5K1",
      "size": 7724464,
      "reboot_required": false,
      "description": "Dell EC NVMe FIPS 7400 RI M.2 2.5.0 MTFDKBA480TDZ, MTFDKBA960TDZ,MTFDKBA800TFC,MTFDKBG1T9TDZ,MTFDKBG3T8TDZ,MTFDKBG960TDZ.",
      "revision_history": "Fixes:\n\n- FW introduces multiple fixes and enhancements."
    }
  ]
}
