{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "m640",
  "name": "M640",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge M640 Updates",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 38,
      "rss": "/m640/urgent/rss.xml",
      "api": "/api/m640/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 122,
      "rss": "/m640/recommended/rss.xml",
      "api": "/api/m640/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 37,
      "rss": "/m640/optional/rss.xml",
      "api": "/api/m640/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/m640/bios/rss.xml",
      "api": "/api/m640/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/m640/chipset/rss.xml",
      "api": "/api/m640/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/m640/diagnostics/rss.xml",
      "api": "/api/m640/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/m640/drivers-for-os-deployment/rss.xml",
      "api": "/api/m640/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 28,
      "rss": "/m640/express-flash-pcie-ssd/rss.xml",
      "api": "/api/m640/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 8,
      "rss": "/m640/fibre-channel/rss.xml",
      "api": "/api/m640/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 3,
      "rss": "/m640/firmware/rss.xml",
      "api": "/api/m640/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/m640/idrac/rss.xml",
      "api": "/api/m640/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 23,
      "rss": "/m640/network/rss.xml",
      "api": "/api/m640/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 72,
      "rss": "/m640/sas-drive/rss.xml",
      "api": "/api/m640/sas-drive"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 10,
      "rss": "/m640/sas-raid/rss.xml",
      "api": "/api/m640/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 43,
      "rss": "/m640/serial-ata/rss.xml",
      "api": "/api/m640/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 3,
      "rss": "/m640/systems-management/rss.xml",
      "api": "/api/m640/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/m640/video/rss.xml",
      "api": "/api/m640/video"
    }
  ],
  "count": 197,
  "updates": [
    {
      "id": "76245d0a584c5ccc82e289fc13f517d6fe16339b10aa85c49a062f45e8a4f53d",
      "name": "DELL System Update, v.2.3.0.2",
      "version": "2.3.0.2",
      "release_id": "RDVR3",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-11-06T11:10:35Z",
      "released": "2026-11-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15213121M/1/Systems-Management_Application_RDVR3_WN64_2.3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RDVR3",
      "size": 30983200,
      "reboot_required": false,
      "description": "DELL System Update (DSU) is a software designed to facilitate the application of updates on various Dell systems. Using DSU you can:\n1.Identify the available updates, select the relevant updates, and deploy the updates on multiple systems.\n2.Maintain consistency in terms of interface and versions across Operating Systems, Repositories, and Systems.",
      "revision_history": "Enhancement :\n\nOS native support with passthrough and rsystemtype iDRAC \n\nFixes :\n\nSecurity Issues"
    },
    {
      "id": "03ecb5327ed4cdd97fae44757da07f3421441023644d60db95116a95b1efcf7c",
      "name": "Dell Server PowerEdge BIOS M640/FC640/M640 Version 2.29.3",
      "version": "2.29.3",
      "release_id": "GYXR4",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Urgent",
      "type": "BIOS",
      "posted": "2026-10-20T23:15:04Z",
      "released": "2026-10-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15150733M/1/BIOS_GYXR4_WN64_2.29.3.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GYXR4",
      "size": 50442224,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced feature sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Fixes:\n- N/A.\n\nEnhancements:\n- This release contains security fixes that address one or more vulnerabilities. Dell recommends that you run the most recent available version of the software and apply any security updates at the earliest opportunity. Upon completion of coordinated vulnerability disclosure activities, Dell will publish a Dell Security Advisory (DSA) providing additional details about the vulnerabilities and associated security updates. Customers are encouraged to subscribe to Dell Security Advisories to receive notifications when advisories are published."
    },
    {
      "id": "fd473c28f7250f2c6d18913dc3111f4d695b92c719953f933d5de9f4f624cd1b",
      "name": "Dell PERC H330 Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "NYKX7",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:21:18Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07211734M/4/SAS-RAID_Firmware_NYKX7_WN64_25.5.9.0001_A15_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NYKX7",
      "size": 25051800,
      "reboot_required": true,
      "description": "Dell PERC H330 Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "5c912c46b71cf36439ff040f72dfd483a636caf6953566b7822e906ce3a8e030",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "version": "25.5.8.0001",
      "release_id": "WRF3Y",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:12:44Z",
      "released": "2020-09-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06547525M/4/SAS-RAID_Firmware_WRF3Y_WN64_25.5.8.0001_A16_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WRF3Y",
      "size": 25507720,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "revision_history": "Fixes:\n-Fixed an isolated issue where manually run controller self-diagnostics would trigger Event 13 (Controller cache discarded due to firmware version incompatibility) on the subsequent reboot.\n\nEnhancements:\n-Enhanced Background Initialization (BGI) and Consistency Check (CC) progress to reduce performance impact when progress is saved (checkpointed).\n  Previous behavior:\n    BGI/CC progress was saved to disk every 5 minutes, this disk access triggered I/O to pause and cache flush, causing a latency increase.\n   New behavior (as of 25.5.8.0001):\n    BGI/CC progress was saved to disk every 5 minutes if an operating system/driver is not loaded.\n          Note: H330 controllers will keep background operations paused while in HII, or until an OS is loaded.\n    When the firmware detects a driver loading, BGI/CC progress will be saved every 4 hours.\n    When a graceful shutdown is performed, the firmware will save progress as part of the shutdown procedure.\n    In the event of ungraceful shutdown/power loss progress will resume from the last saved checkpoint.\n          Note: Progress Events remain unchanged and will be observed at the same interval."
    },
    {
      "id": "493d6478a65cc15bfbb6c50488217952ef5f4c79a9bf9c593c18ece67ef5ed3e",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "700GG",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-05T16:45:15Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07217671M/3/SAS-RAID_Firmware_700GG_WN64_25.5.9.0001_A17_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=700GG",
      "size": 25505712,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "2415829e7fbdf226548b1edf590674de41d581bd80057b3e4aaec2f1338ab236",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI SED Firmware release",
      "version": "2.4.0",
      "release_id": "F1GP2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:40:38Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518104M/4/Express-Flash-PCIe-SSD_Firmware_F1GP2_WN64_2.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F1GP2",
      "size": 24262024,
      "reboot_required": true,
      "description": "Dell EC NVMe SED 7450 RI M.2 x80, MTFDKBA480TFR, MTFDKBA960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3d1046f353505af029bc9659b941ee4de30f631c58d039a12fdfa117869c68f0",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 RI FIPS Firmware release",
      "version": "3.4.0",
      "release_id": "TYFC3",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-01T15:25:09Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13517480M/4/Express-Flash-PCIe-SSD_Firmware_TYFC3_WN64_3.4.0_A03_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TYFC3",
      "size": 24262136,
      "reboot_required": true,
      "description": "Dell EC NVMe FIPS 7450 RI M.2, 3.4.0, 22x80 x110: MTFDKBA480TFR MTFDKBA960TFR MTFDKBG960TFR",
      "revision_history": "Fixes:\n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "113d023faa13725bb8fbe0e0815d6451ee036b77483afd1f68ec9c85755126e9",
      "name": "Dell iDRAC Service Module Installer for OS DUP v5.4.2.0",
      "version": "5.4.2.0",
      "release_id": "WMJ1N",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2026-09-29T07:14:37Z",
      "released": "2025-10-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13800885M/4/Systems-Management_Application_WMJ1N_WN64_5.4.2.0_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WMJ1N",
      "size": 34063584,
      "reboot_required": false,
      "description": "iDRAC Service Module (iSM) is a lightweight software service that better integrates operating system (OS) features with iDRAC and can be installed on Dell’s yx5x or later generation of PowerEdge servers. iSM provides OS-related information to the iDRAC and adds capabilities such as LC log event replication into the OS log, WMI support (including storage), iDRAC SNMP alerts via OS, iDRAC hard reset and remote full Power Cycle. iSM automates SupportAssist report collection process for iDRAC leading to faster issue resolution. iSM has very little impact on the host processor and smaller memory footprint than \"in-band\" agents such as Dell EMC OpenManage Server Administrator (OMSA), thus expanding iDRAC management into supported host operating systems.",
      "revision_history": "Fixes:\n=====\nNA\nEnhancements:\n============\nEnabled SUSE LINUX ENTERPRISE SERVER 16"
    },
    {
      "id": "f24b9cd60a3fe82f3ea65e0c39f681ff1a85c52d7487b59813856d64329a923d",
      "name": "Dell OS Driver Pack",
      "version": "24.01.04",
      "release_id": "NR0JY",
      "category": "Drivers for OS Deployment",
      "category_slug": "drivers-for-os-deployment",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2026-09-15T05:25:11Z",
      "released": "2024-01-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11189290M/2/Drivers-for-OS-Deployment_Application_NR0JY_WN64_24.01.04_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NR0JY",
      "size": 106998088,
      "reboot_required": false,
      "description": "OS Driver Pack for PowerEdge 14G servers. This Driver Pack contains applicable storage and embedded LOM drivers to support OS installation using the Dell Lifecycle Controller",
      "revision_history": "N/A"
    },
    {
      "id": "4175d48092d0c8309e216153c7b743dbea59b1590da4dedc03c2970bca816070",
      "name": "MICRON 5100 max Pro RI/ Pro boot M.2 SATA \u0026apos;L013\u0026apos; FW for model number(s) MTFDDAV240TCB, MTFDDAV480TCB, MTFDDAV960TCB, MTFDDAV1T9TCB, MTFDDAK240TCB, MTFDDAK480TCB, MTFDDAK960TCB, MTFDDAK1T9TCB",
      "version": "L013",
      "release_id": "RTND5",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-04T14:23:56Z",
      "released": "2026-08-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14983889M/1/Serial-ATA_Firmware_RTND5_WN64_L013_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RTND5",
      "size": 26470688,
      "reboot_required": true,
      "description": "This release contains firmware version L013 for MICRON model number(s) MTFDDAV240TCB, MTFDDAV480TCB, MTFDDAV960TCB, MTFDDAV1T9TCB, MTFDDAK240TCB, MTFDDAK480TCB, MTFDDAK960TCB, MTFDDAK1T9TCB.  Capacity of 5100 max Pro boot 240GB, 480GB, 960GB, 1.92TB. Pro RI 240GB, 480GB, 960GB and 1.92TB",
      "revision_history": "Fixes:\n1. D0DL013 addresses this issue.  The updated behavior will be:\n2. LogEntryCnt = 65,535 Exit the workload log function directly; no workload log entry is recorded.\n3. LogEntryCnt = 0 to 65,534 Workload log recording continues as originally designed."
    },
    {
      "id": "40a5d823af38ca2ebe7cbf8287901fe09aafe6fca47e6048df8429e0f104815d",
      "name": "Microsoft Windows x64 management driver for BOSS",
      "version": "1.2.0.1052",
      "release_id": "8KKVC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-31T12:12:02Z",
      "released": "2021-07-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07524633M/9/SAS-RAID_Driver_8KKVC_WN64_1.2.0.1052_A02_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8KKVC",
      "size": 17014984,
      "reboot_required": false,
      "description": "Microsoft Windows x64 management driver for BOSS",
      "revision_history": "Fixes: None,\nEnhancements: YES , Signed Binaries\nConsole Management Driver for all Windows Operating systems\nSupport for Windows Azure HCI Stack \u0026 Windows 2022 enabled"
    },
    {
      "id": "e030fecbf94eb9512ae1dfa4fb776046fd4612d06268cb14e6909c5d697489ae",
      "name": "BOSS-S1 Modular firmware",
      "version": "2.6.13.3025",
      "release_id": "F9F16",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-27T11:07:40Z",
      "released": "2023-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09214778M/11/SAS-RAID_Firmware_F9F16_WN64_2.6.13.3025_A08_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F9F16",
      "size": 23542872,
      "reboot_required": true,
      "description": "BOSS-S1 Modular ROM version 2.6.13.3025",
      "revision_history": "Fixes : HW Re-spin \nAddressed false M.2 failures reported due to thermal issues\n\nEnhancements : Added new SDID 0x2260 on BOSS-S1 controller"
    },
    {
      "id": "859b1c10d2229812e6b4b234a8036d9ba3fbcf67d80def57f60306af9075dbb9",
      "name": "iDRAC 7.00.00.185",
      "version": "7.00.00.185",
      "release_id": "K7H6Y",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-08-27T10:59:40Z",
      "released": "2026-08-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14949970M/1/iDRAC-with-Lifecycle-Controller_Firmware_K7H6Y_WN64_7.00.00.185_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K7H6Y",
      "size": 228652424,
      "reboot_required": false,
      "description": "The Integrated Dell Remote Access Controller (iDRAC) is designed to make server administrators more productive and improve the overall availability of Dell servers. iDRAC also provides an out-of-band mechanism for configuring the platform, applying firmware updates, saving or restoring a system backup, or deploying an operating system, either by using a GUI or a remote scripting language, such as Redfish or RACADM.",
      "revision_history": "Fixes:\n- This release contains security fixes that address one or more vulnerabilities. Dell recommends that you run the most recent available version of the software and apply any security updates at the earliest opportunity. Upon completion of coordinated vulnerability disclosure activities, Dell will publish a Dell Security Advisory (DSA) providing additional details about the vulnerabilities and associated security updates. Customers are encouraged to subscribe to Dell Security Advisories to receive notifications when advisories are published..\n\nEnhancements:\n- N/A"
    },
    {
      "id": "0b7e011822d4c6c20609a00e56c35d65e1d85a2098333e8ec52877cc36619793",
      "name": "Broadcom NetXtreme network device firmware, 23.1",
      "version": "23.11.4",
      "release_id": "MGPTR",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2026-08-10T23:18:15Z",
      "released": "2024-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12155612M/4/Network_Firmware_MGPTR_WN64_23.11.4_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MGPTR",
      "size": 21657376,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for Broadcom NetXtreme devices.   This release should be used with the Broadcom 23.1 device drivers.",
      "revision_history": "Fixes:\n- Broadcom NIC fails to get DHCP IP on a Genoa dual 96-core proc config.\n\nEnhancements:\n- none"
    },
    {
      "id": "559e792d7369318d22be9a9b8c82cb7c3e6f91193952b11ebf8a9ba38e90ab7c",
      "name": "Toshiba EF0A for model number(s) AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY",
      "version": "EF0A",
      "release_id": "THG5M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T06:27:04Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607520M/2/SAS-Drive_Firmware_THG5M_WN64_EF0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=THG5M",
      "size": 26661096,
      "reboot_required": false,
      "description": "This release contains firmware version EF0A for Toshiba drives. Vendor model numbers AL15SEB030NY, AL15SEB060NY, AL15SEB120NY, AL15SEB18EQY, AL15SEB24EQY, AL15SEB18EPY and AL15SEB24EPY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures.\n- Fixed Command timeout (or 06/29/04) issue.\n  This problem may occur when the queued time for a read or write command \n  exceeds the Command Aging Timer and the SYNCHRONIZED CACHE \n  command is also queued.\n- Fixed random write iops degradation after sequential read.\n    4k Random write -\u003e Seq read -\u003e 4k random write. In this test sequence, \n    2nd 4k random write iops may drop.\n- Fixed a wrong LBA report in SENSE DATA when Read Buffer CRC \n    error(03/11/02) occurs."
    },
    {
      "id": "fdd84063aa261dc77f4bd896bc2458570e08fd9fa0f7c7a07d843154dbc72955",
      "name": "Initial release of Toshiba AL15SE+ HDD Model Number AL15SEB09EQY",
      "version": "EF82",
      "release_id": "VJWX0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-05-30T04:21:30Z",
      "released": "2026-05-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14607338M/2/SAS-Drive_Firmware_VJWX0_WN64_EF82_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJWX0",
      "size": 26660216,
      "reboot_required": false,
      "description": "This release contains firmware version EF82 for Toshiba drives. Vendor Model Number AL15SEB09EQY.",
      "revision_history": "- Dynamic range adjustment to mitigate SVC GMA Driver failures."
    },
    {
      "id": "832f358867a87dbab42fc379e286da1d8bd7b8fd87d614862be22df1da90058d",
      "name": "Hynix SE5130 DG02 Firmware for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N",
      "version": "DG02",
      "release_id": "17C3M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-03-09T14:43:52Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14279570M/1/Serial-ATA_Firmware_17C3M_WN64_DG02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17C3M",
      "size": 25675424,
      "reboot_required": true,
      "description": "This is the initial firmware release of HYNIX, SE5130, DG02 for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N.",
      "revision_history": "Fixes:\n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "81f3f0352d8bd36411685ecdc38bb84a5468b5da7af2f25ab5aab2a8dfeff25a",
      "name": "Dell Express Flash NVMe P4510/P4610 PCIe SSD Firmware Release",
      "version": "VDV1DP25",
      "release_id": "7VJGR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-01-20T19:54:52Z",
      "released": "2026-01-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14110355M/1/Express-Flash-PCIe-SSD_Firmware_7VJGR_WN64_VDV1DP25_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7VJGR",
      "size": 27548008,
      "reboot_required": true,
      "description": "This release contains firmware for Intel drives with the following model numbers: Dell Express Flash Nvme P4510 1TB, Dell Express Flash NVMe P4510 2TB, Dell Express Flash NVMe P4510 4TB, Dell Express Flash NVMe P4510 8TB, Dell Express Flash NVMe P4610 1.6TB, Dell Express Flash NVMe P4610 3.2TB, Dell Express Flash NVMe P4610 6.4TB"
    },
    {
      "id": "cca5695e4a8e61074fdc1de3a322725393df6e48f8498fa5f2dd6e2c301186f7",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "version": "1.2.0",
      "release_id": "71KRG",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-12-16T18:48:47Z",
      "released": "2025-09-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13990425M/1/Express-Flash-PCIe-SSD_Firmware_71KRG_WN64_1.2.0_A08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=71KRG",
      "size": 29639544,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a AGN Firmware Maintenance Release",
      "revision_history": "Fixes:\n\n1. Improvements to drive internal logging.\n2. Improvements to SMART logging and notification.\n3. Resolved sideband firmware download issue.\n\nEnhancements:\n\n1. Additional support added for firmware update for Dell 17th generation servers.\n2. Additional support added for firmware update for Dell PERC 12 and 13 controllers."
    },
    {
      "id": "02286d72f669c005452804c6682322adb99d5abb1748762b5742f8ed0eacaeb9",
      "name": "Samsung HK58 FW for PM897a SATA drive program for model number(s) MZ7L3480HELTAD3, MZ7L3960HELAAD3, MZ7L31T9HENAAD3, MZ7L33T8HENAAD3",
      "version": "HK58",
      "release_id": "V5XNY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T15:24:01Z",
      "released": "2025-09-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13895112M/1/Serial-ATA_Firmware_V5XNY_WN64_HK58_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V5XNY",
      "size": 23609288,
      "reboot_required": true,
      "description": "This update includes optimizations to reset handling, log collections, and SMART attribute handling.  Version HK58 firmware for Samsung PM897a SATA SSDs, models MZ7L3480HELT-00AD3,  MZ7L3960HELA-00AD3,  MZ7L31T9HENA-00AD3,  MZ7L33T8HENA-00AD3.",
      "revision_history": "Fixes:\n\n- Altered Reset handling to respond to all COMRST commands within 1 sec.\n- Altered DRAM allocation for live dumps, to eliminate FW assert due to max. allocation count\n- Eliminated debug log check during Open, to eliminate fake UECC written during DTT shutdown\n\nEnhancement:\n\n- Changed SMART Attributes 173, 175, and 177 to Advisory."
    },
    {
      "id": "e846d6c1ff5659ce2b77ca6d67f8125ae920ef3bc41f09ffce056334e4fc547b",
      "name": "This release contains firmware version HL58 for supplier model number(s) MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "version": "HL58",
      "release_id": "D5D3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-20T15:19:35Z",
      "released": "2025-09-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13895080M/1/Serial-ATA_Firmware_D5D3W_WN64_HL58_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D5D3W",
      "size": 23613616,
      "reboot_required": true,
      "description": "This update includes optimizations to reset handling, log collections, and SMART attribute handling.  Version HL58 firmware for Samsung PM893a SATA SSDs, models  MZ7L3960HELT-00AD3,  MZ7L31T9HELA-00AD3,  MZ7L33T8HELA-00AD3, MZ7L37T6HELA-00AD3.",
      "revision_history": "Fixes: \n\n- Altered Reset handling to respond to all COMRST commands within 1 sec.\n- Altered DRAM allocation for live dumps, to eliminate FW assert due to max. allocation count\n- Eliminated debug log check during Open, to eliminate fake UECC written during DTT shutdown\n\nEnhancement:\n\n- Changed SMART Attributes 173, 175, and 177 to Advisory."
    },
    {
      "id": "19e4e741289fa377d8952ffbe882abe72120f68c9c5e74a51cbecf29719adba9",
      "name": "Hynix SE5031 (ISE MU) DD03 Firmware for model number(s) HFS480G32FEH-BA10A, HFS960G32FEH-BA10A, HFS1T9G32FEH-BA10A, HFS3T8G32FEH-BA10A.",
      "version": "DD03",
      "release_id": "174WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-11-12T10:51:25Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13855287M/1/Serial-ATA_Firmware_174WY_WN64_DD03_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=174WY",
      "size": 26478904,
      "reboot_required": true,
      "description": "This release contains firmware version for Hynix SE5031 (ISE MU) DD03 Firmware model number(s) HFS480G32FEH-BA10A, HFS960G32FEH-BA10A, HFS1T9G32FEH-BA10A, HFS3T8G32FEH-BA10A.",
      "revision_history": "Fixes: \n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "dbdfbff4fda3b33a0f47c4f2c9593f17f3ce0e05b9698b3ff06a66b44465d1ae",
      "name": "Hynix SE5110 ISE RI DZ04 Firmware for model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N",
      "version": "DZ04",
      "release_id": "HFTMG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-11-12T10:51:19Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13855285M/1/Serial-ATA_Firmware_HFTMG_WN64_DZ04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HFTMG",
      "size": 26870384,
      "reboot_required": true,
      "description": "This release contains initial firmware DZ04 for Hynix SE5110 ISE. Model number(s) HFS480G3H2X069N, HFS960G3H2X069N, HFS1T9G3H2X069N, HFS3T8G3H2X069N.",
      "revision_history": "Fixes: \n\nFix1: Add a sequence to clear the \"\"health monitoring done bit\"\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while."
    },
    {
      "id": "7fd7af210790eda1f74415dd2f34089d430c7df10a5b4f14bc700d31e45d055a",
      "name": "Samsung PM883a RI SSDR, FW HG61 for model number(s) MZ7LH240HBHQAD3, MZ7LH480HBHQAD3, MZ7LH960HBJRAD3, MZ7LH1T9HALTAD3, MZ7LH3T8HALTAD3, and MZ7LH7T6HALAAD3.",
      "version": "HG61",
      "release_id": "3GHD6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-11-10T14:08:33Z",
      "released": "2025-09-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13842682M/1/Serial-ATA_Firmware_3GHD6_WN64_HG61_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3GHD6",
      "size": 23504296,
      "reboot_required": true,
      "description": "This update includes optimizations to reset handling, log collections, and SMART attribute handling. Version HG61 firmware for Samsung PM883a SATA SSDs, models MZ7LH240HBHQAD3,MZ7LH480HBHQAD3,MZ7LH960HBJRAD3,MZ7LH1T9HALTAD3,MZ7LH3T8HALTAD3,and MZ7LH7T6HALAAD3.",
      "revision_history": "Fixes:\n\n- Altered Reset handling to respond to all COMRST commands within 1 sec.\n- Altered DRAM allocation for live dumps, to eliminate FW assert due to max. allocation count.\n\nEnhancements:\n\n- Changed SMART Attributes 173, 175, and 177 to Advisory."
    },
    {
      "id": "084c4c862eb04bca11886df3cc480d08a1b762a058189ccf46755ff6564037c4",
      "name": "Dell Express Flash NVMe P5520/P5620 PCIe SSD Firmware Release",
      "version": "1.5.0",
      "release_id": "12W9R",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-10-31T17:04:04Z",
      "released": "2025-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13807766M/1/Express-Flash-PCIe-SSD_Firmware_12W9R_WN64_1.5.0_A04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=12W9R",
      "size": 27905664,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P5520/5620 PCIe SSD Firmware Release MR4"
    },
    {
      "id": "fb8ff768e354cd12faf953be34147b12bc0139fd95ea687727593f9c06bbd816",
      "name": "Dell Express Flash NVMe 7450 M.2 SSD GEN4 (RI\\MU) ISE Firmware release",
      "version": "1.4.0",
      "release_id": "JHKXR",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-10-08T10:13:10Z",
      "released": "2025-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13518113M/2/Express-Flash-PCIe-SSD_Firmware_JHKXR_WN64_1.4.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JHKXR",
      "size": 18728752,
      "reboot_required": true,
      "description": "Dell EC NVMe ISE 7450 MU and RI M.2 x80,x110, MTFDKBA480TF, MTFDKBA960TF, MTFDKBA800TF, MTFDKBG960TF, MTFDKBG1T9TF, MTFDKBG3T8TF",
      "revision_history": "Fixes: \n\n1. Implemented functionality to allow sanitize crypto erase while in read-only mode.\n2. Increased SDA setup time from 110ns to 220ns.\n3. Clear the SMBus FIFO when an interrupt due to a TX Abort occurs and allow the response to be retried.\n4. Improved firmware handling of EEPROM reads to handle situations in which other OOB commands may be in flight. This ensures that the EEPROM can be read successful and the drive can respond to the host.\n5. Added a firmware workaround in the SDA stuck low error handling to complete the interrupted response transfer when the SDA stuck low is detected by the drive.\n6. Reset the MCTP Endpoint after FLR so that all non-Control Message MCTP commands will be dropped. Host will then need to set the Endpoint ID ensuring that any future responses will have a non-zero BDF.\n7. Mutex lock the MCTP variable to allow it to only be accessed by a single thread and update the firmware to ensure that internal MCTP variables will be cleared during a reset.\n8. Workaround implemented to allow the drive to reset communications to the power backup IC and ensure the capacitors are accurately tested.\n9. FW will enable FTL into operational state when FW receive the mi admin command over OOB after host triggered the SHN\n10. When OOB commands received and aborted during the SSD shutdown flow causing the next commands like AWOR/AWR to panic the drive, In this specific FW shutdown scenario, free the FW resource assignments associated with the received OOB commands when aborted by the host.\n11. Modify the firmware to adjust the CAP.TO values to 56 seconds.\n12. The internal VDM buffer was increased in size to prevent the overflow and ensure the FW image is successfully downloaded to the drive. The MTFA value reported by the drive was increased from 1 second to 9.9 seconds.\n13. Fix is to increase the size of the buffer to prevent losing firmware download packets. This ensures that the entire FW image is successfully downloaded to the drive allowing the firmware update process to continue successfully.\n14. Update to prevent the CSTS.RDY bit from being set as a result of an MI Admin command. CSTS.RDY can only be set after CC.EN=1 has been set by the host.\n15. Ensure MPR response follows the 12-byte error response format rather than the 24-byte NVMe admin command response format.\n16. Fix firmware to ensure that admin commands with an htag of 0 will be processed ensuring that no commands become lost.\n17. Improve the read telemetry command execution by utilizing the DMA hardware engine to manipulate the DRAM buffer data. This significantly reduces the telemetry log command processing time and prevents the PCIe Memory read from being blocked.\n\nEnhancements:\n\n1. Added Support for OCP 0xC0 Log Page in PowerEdge FW\n2. Aligned 7450 U.2/M.2 FRU to Dell PowerEdge FRU Content Specification V2.5\n3. Add Read look ahead feature in FW.\n4. Changed Micron 7450 to Follow SFF-8447 for LBA count"
    },
    {
      "id": "3735b6b54fcf04cd59cca7137654bb59c8fcdefecff53476ea296922b2fd6175",
      "name": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\nFW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.",
      "version": "PV10",
      "release_id": "8R6W6",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-25T09:20:50Z",
      "released": "2025-09-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13676887M/1/Serial-ATA_Firmware_8R6W6_WN64_PV10_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8R6W6",
      "size": 23949896,
      "reboot_required": false,
      "description": "Initial release of WDC Vela-A 512n SATA HDD 2TB capacity, Model number HUS726T2TALA6L0.\n'FW update for WDC Vela-A 512n SATA HDD, Model number HUS726T4TALA6L0.\nIncludes FW update to add recognition of 2TB SATA capacity part number",
      "revision_history": "FW update to add Dell Part Number for newly added 2TB capacity"
    },
    {
      "id": "ea458c1dc12923103402934995464872ef26674afa20f185adc4120635d38acd",
      "name": "Samsung PM893 SATA SSDs for HJ64 firmware for models MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3",
      "version": "HJ64",
      "release_id": "T3HX9",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-18T15:53:37Z",
      "released": "2025-08-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652326M/1/Serial-ATA_Firmware_T3HX9_WN64_HJ64_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T3HX9",
      "size": 24511256,
      "reboot_required": true,
      "description": "This update includes critical changes to address PDL failures and SMART attribute reporting, along with enhancements to reduce  Version HJ64 firmware for Samsung PM893 SATA SSDs, models MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3.",
      "revision_history": "Fixes:\n- Altered exception handling to trigger SWI for all exceptions, to address the PDL issue.\n- Changed SMART attributes 173, 175, and 177 to Warning from Pre-Failure to match Dell specification.\n- Changed live dump DRAM allocation procedure to create a new each cycle, to eliminate FW assert / Error Mode due to DRAM threshold limit exceeded.\n- Fixed data mismatch caused by back-to-back SCT commands by flushing data to NAND befor each SCT command.\nEnhancements: \n- Allow Secure Erase command in Error Mode.\n- Enable extended Sequential Write check, to maintain sequential workload with few random commands included."
    },
    {
      "id": "0a1488415dc0e94ad9aeb1cbe1f7f5c3bc14a09653439f7d43842c0c70961d57",
      "name": "Samsung PM897 SATA SSDs for HH64 firmware for models MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "version": "HH64",
      "release_id": "VRG4Y",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-09-18T15:48:14Z",
      "released": "2025-08-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER13652260M/1/Serial-ATA_Firmware_VRG4Y_WN64_HH64_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VRG4Y",
      "size": 24507344,
      "reboot_required": true,
      "description": "This update includes critical changes to address PDL failures and SMART attribute reporting, along with enhancements to reduce  Version HH64 firmware for Samsung PM897 SATA SSDs, models MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3.",
      "revision_history": "Fixes:\n- Altered exception handling to trigger SWI for all exceptions, to address PDL issue.\n- Changed SMART attributes 173, 175, and 177 to Warning from Pre-Failure to match Dell specification.\n- Changed live dump DRAM allocation procedure to create new each cycle, to eliminate FW assert / Error Mode due to DRAM threshold limit exceeded.\n- Fixed data mismatch caused by back-to-back SCT commands by flushing data to NAND befor each SCT command.\nEnhancements: \n- Allow Secure Erase command in Error Mode.\n- Enable extended Sequential Write check, to maintain sequential workload with few random commands included."
    },
    {
      "id": "bc20d7bbdd73425a126be1aa9a9baaf4273de370b22b151f7af3fa187cb42b4a",
      "name": "Dell Express Flash NVMe PCIe SSD CM6 Maintenance Firmware Release",
      "version": "2.2.2",
      "release_id": "GMM6V",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-20T03:23:06Z",
      "released": "2024-07-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11805909M/3/Express-Flash-PCIe-SSD_Firmware_GMM6V_WN64_2.2.2_A08_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GMM6V",
      "size": 28521944,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CM6 Firmware Maintenance Release"
    },
    {
      "id": "6396852fbfb009e28e3f475ee211608cc3c6c150d5c5f6c446c6b8c8fa29239f",
      "name": "Dell Express Flash NVMe PCIe SSD PM1725b Firmware Release",
      "version": "1.2.2",
      "release_id": "NC07Y",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T09:46:54Z",
      "released": "2025-02-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12666252M/3/Express-Flash-PCIe-SSD_Firmware_NC07Y_WN64_1.2.2_A05_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NC07Y",
      "size": 29801400,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD PM1725b firmware release",
      "revision_history": "New Feature \u0026 Performance enhancements:\nN/A\n\nBug Fixes:\n1. Disable arbitration at the beginning of NSSR so that no invalid status are sent to the host while NSSR is being processed.\n2. Firmware is fixed to set the limit to the suspend check and if no responses back for some time (ex, 5ms), firmware will reset/recover NM code.\n3. Ignore second(SPAM) restart after code completes the first restart."
    },
    {
      "id": "41d8ddf307b4ef32924e88af9618acf8165484bb258955e0c6381fffd74cec21",
      "name": "Seagate SBTA for Skybolt ServoBP program for model number(s) CL2400MM0149",
      "version": "SBTA",
      "release_id": "HH6J1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T08:02:18Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12677112M/2/SAS-Drive_Firmware_HH6J1_WN64_SBTA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HH6J1",
      "size": 23874432,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512n ISE. Model Number CL2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "4c6ed6166ab2e1a3e699af648e5457cd81edd18f87e2beea7561f7262fa1fa6d",
      "name": "Seagate SBSA for Skybolt ServoBP program for model number(s) BL2400MM0159",
      "version": "SBSA",
      "release_id": "00P56",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:22:58Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676520M/2/SAS-Drive_Firmware_00P56_WN64_SBSA_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=00P56",
      "size": 23874416,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt ServoBP 512e ISE.  Model Number BL2400MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "b3756f56e76fb6fdf6d53d9bc0bb41fa37aaf9ec858ba959301334044cd538e7",
      "name": "DELLSLDM Youngsville-RR DL7C for model numbers SSDSC2KB076TZR, SSDSC2KB038TZR, SSDSC2KB019TZR, SSDSC2KB960GZR, SSDSC2KB480GZR, SSDSCKKB480GZR, SSDSC2KB240GZR, SSDSCKKB240GZR, SSDSC2KG038TZR, SSDSC2KG019TZR, SSDSC2KG960GZR, SSDSC2KG480GZR",
      "version": "DL7C",
      "release_id": "VJPKG",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-08-19T07:07:49Z",
      "released": "2025-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12600340M/4/Serial-ATA_Firmware_VJPKG_WN64_DL7C_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJPKG",
      "size": 22988728,
      "reboot_required": false,
      "description": "This is a firmware release for DELLSLDM Youngsville-RR  DL7C firmware for Model number(s) SSDSC2KB240GZR, SSDSC2KB480GZR, SSDSC2KB960GZR, SSDSC2KB019TZR, SSDSC2KB038TZR, SSDSC2KB076TZR, SSDSCKKB240GZR, SSDSCKKB480GZR,SSDSC2KG480GZR, SSDSC2KG960GZR, SSDSC2KG019TZR, SSDSC2KG038TZR",
      "revision_history": "Issue: During a warm Reboot the YVRR drive may intermittently disappear when connected to the PERC H965i\nFix: DL7C FW now addresses this issue\nIssue: PLI capacitor charge flag not set leads drive to enter disable logical mode\nFix: DL7C FW now addresses this issue"
    },
    {
      "id": "3327174b72088c6b72541588c503c14db0065a16884a08012949b2120919cf43",
      "name": "Seagate ST7G for model number(s) ST1800MM0159 and ST2400MM0159",
      "version": "ST7G",
      "release_id": "7N5DH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:05:15Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676236M/4/SAS-Drive_Firmware_7N5DH_WN64_ST7G_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7N5DH",
      "size": 23857864,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Skybolt 4Kn ISE.  Model Numbers ST2400MM0159 and ST1800MM0159.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "Add support for Hynix V8 NAND part."
    },
    {
      "id": "d5b4cea0b433c0dc5f334945213d8a951654857385c555988b21866cfaa38c0c",
      "name": "Firmware refresh for Seagate ST5J for model number(s) DL1800MM0159 and DL2400MM0159",
      "version": "ST5J",
      "release_id": "DRHV4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-08-19T07:02:48Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12671974M/4/SAS-Drive_Firmware_DRHV4_WN64_ST5J_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DRHV4",
      "size": 23857936,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512e ISE.  Model Numbers DL2400MM0159 and DL1800MM0159.",
      "revision_history": "Firmware modification to add support for new V8 NAND part."
    },
    {
      "id": "c638deaf80243558c60acd54bf33cf360187a5e6e9fbde142610b15697283e43",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.1",
      "version": "23.10.2",
      "release_id": "KDMJJ",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-14T05:26:52Z",
      "released": "2024-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12155607M/3/Network_Driver_KDMJJ_WN64_23.10.2_231.1.162.1_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KDMJJ",
      "size": 14101552,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- Broadcom NIC fails to get DHCP IP on a Genoa dual 96-core proc config.\n\nEnhancements:\n- none"
    },
    {
      "id": "6b8fe0e8d91ff1271a42ada59a153ff6182e02d9af7e3d6ab2ede54b99a9287d",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 23.0",
      "version": "23.00.0",
      "release_id": "GJ9N4",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2025-08-14T05:26:36Z",
      "released": "2024-09-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11901569M/3/Network_Driver_GJ9N4_WN64_23.00.0_230.1.116.0_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GJ9N4",
      "size": 14389968,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.\nNOTE: Independent of the Reboot Required indication, it may be determined at runtime that a reboot is necessary to activate the driver.",
      "revision_history": "Fixes:\n- BCM5719 missing Jumbo MTU and LSO options in Advanced Properties.\n\nEnhancements:\n- Add support for Windows Server 2025."
    },
    {
      "id": "56221de0237fbeeb680e5eac2cb8d3e0f72799000d1986cf8fb68d7d02d297cd",
      "name": "Seagate SSEJ for model number(s) ST2400MM0149",
      "version": "SSEJ",
      "release_id": "KHJ9C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:13:51Z",
      "released": "2025-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12676334M/3/SAS-Drive_Firmware_KHJ9C_WN64_SSEJ_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHJ9C",
      "size": 24679816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Skybolt 512n ISE. Model Number ST2400MM0149.\nFirmware modification to add support for new V8 NAND part.",
      "revision_history": "- Add support for Hynix V8 NAND part."
    },
    {
      "id": "94586f99bddb6d07e51ebf78479fa5de5fb353777dec7e7bb0b73c704b3c21bf",
      "name": "Dell Datacenter NVME RI AGN ISE",
      "version": "1.1.1",
      "release_id": "XMFKX",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:50:32Z",
      "released": "2024-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12037085M/2/Express-Flash-PCIe-SSD_Firmware_XMFKX_WN64_1.1.1_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XMFKX",
      "size": 30415680,
      "reboot_required": false,
      "description": "Dell Datacenter NVME RI AGN ISE",
      "revision_history": "Fixes:\n\n1. Updated DUP framework for 17G server platforms."
    },
    {
      "id": "a98c02887bb372e7fadcc37e7683cc77cf178f75e811b60543320fbd00d0b70c",
      "name": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance Release",
      "version": "1.3.0",
      "release_id": "RPTG2",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-20T11:09:38Z",
      "released": "2025-01-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12505166M/2/Express-Flash-PCIe-SSD_Firmware_RPTG2_WN64_1.3.0_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RPTG2",
      "size": 29108768,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe 7450 ISE PCIe SSD Firmware Maintenance  Release",
      "revision_history": "Fixes:  \n\n1. Firmware will preserve the CSTS.CFS bit as long as the drive is in panic. \n2. Disable Latency Tolerance Reporting (LTR) in FW\n3. Implemented a fix to ensure that the drive does not miss the TS1 from the host which will allow the host to exit the L1 Entry state and prevent the link from being reset.\n4. FW now shows specific values per capacity in the Sanitize Status log page\n5. Resolved the issue of the drive internal bit remaining set after a reboot. This ensures that AERs will not be disabled.\n6. Improve APL handling in FW.\n7. Improve handling of invalid commands in FW to prevent asserts.\n8. Improve TRIM handling in FW\n9. Improve thermal shutdown behavior to avoid assert. \n10. Improve PERST handling to prevent assert in this situation \n11. Improved OOB command handling in FW especially during shutdown\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "ceff23d80cbb8541baa365b1fd0640fa4a06d13481f5404c1fc5497f6dbd404c",
      "name": "Seagate SSC8 for model number(s) ST1200MM0069",
      "version": "SSC8",
      "release_id": "P9R4D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T11:08:58Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11500432M/2/SAS-Drive_Firmware_P9R4D_WN64_SSC8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P9R4D",
      "size": 24522608,
      "reboot_required": false,
      "description": "This release contains firmware version SSC8 for Seagate drives. Vendor model numbers ST1200MM0069..",
      "revision_history": "Fixes:\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "771aacec8b2f181d2931276a870acf035ada5af80f2174a808e8f6fe28a17150",
      "name": "HGST RS09 for Vela-AP SAS  ISE model number(s) HUS728T6TAL5200, HUS728T6TAL4200",
      "version": "RS09",
      "release_id": "8GM6M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-04-11T11:06:44Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025815M/2/SAS-Drive_Firmware_8GM6M_WN64_RS09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8GM6M",
      "size": 24607448,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SAS HDD, Model number HUS728T6TAL5200.\nFW update for WDC Vela-AP 4Kn SAS HDD, Model number HUS728T6TAL4200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "9d3a909718077b49b7c8c9902c53facf85f1cfdfc24edabfce073cd264cc800c",
      "name": "Hitachi PU09 for Vela-A ISE model number(s) HUS726T4TALS200",
      "version": "PU09",
      "release_id": "J5K8G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T11:03:41Z",
      "released": "2024-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024400M/2/SAS-Drive_Firmware_J5K8G_WN64_PU09_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J5K8G",
      "size": 24727008,
      "reboot_required": false,
      "description": "FW update for WDC Vela-A 512n SAS HDD, Model number HUS726T4TALS200.\n\n- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "6cb9b2e14559a89fe993a07e8c8367a371dc1253168afd133677270b5bcb3eec",
      "name": "Seagate ST38 for model number(s) ST600MM0069 and ST1200MM0099",
      "version": "ST38",
      "release_id": "FFN16",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-04-11T10:22:22Z",
      "released": "2024-05-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11502881M/2/SAS-Drive_Firmware_FFN16_WN64_ST38_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FFN16",
      "size": 24522520,
      "reboot_required": false,
      "description": "This release contains firmware version ST38 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes:\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "736e89923bb3c28df28dc52a33909657ef3c7f17816fa6be7cd3ade0082728b9",
      "name": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "version": "C40E",
      "release_id": "57MM2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:28:10Z",
      "released": "2024-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374876M/2/SAS-Drive_Firmware_57MM2_WN64_C40E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=57MM2",
      "size": 24391360,
      "reboot_required": false,
      "description": "This release contains FW revision C40E for model numbers KPM7WVUG960G, KPM7WVUG1T92, KPM7WVUG3T84, KPM7WVUG7T68,KPM7WVUG800G, KPM7WVUG1T60, KPM7WVUG3T20, KPM7WVUG6T40, KPM7WVUG12T8,KPM7WRUG960G, KPM7WRUG1T92, KPM7WRUG3T84, KPM7WRUG7T68, KPM7WRUG15T3",
      "revision_history": "Fixes: \n\n- Fix1: FW is fixed to execute the flush process and Flash Memory parameter modification process exclusively.\n- Fix2: Fixed that the host I/O proceed by the skip of GC if the validity determination process of user data takes time.\n- Fix3: Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "2d586d18bf6bfd668a4b76e782765a56bb78bffe1a219c60613e9b1ae474dbde",
      "name": "Model numbers are KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8, KPM7XRUG960G, KPM7XVUG800G, KPM7XMUG400G, KPM7XMUG800G, KPM7XMUG1T60",
      "version": "C10E",
      "release_id": "T21WT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T06:11:55Z",
      "released": "2024-06-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11374981M/2/SAS-Drive_Firmware_T21WT_WN64_C10E_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T21WT",
      "size": 24314272,
      "reboot_required": false,
      "description": "This release contains firmware version C10E for Kioxia PM7 24Gbps SAS 2.5 (10WPD, 1WPD, 3WPD).\nModel numbers are KPM7XMUG400G, KPM7XMUG800G, and KPM7XMUG1T60,\nKPM7XVUG800G, KPM7XVUG1T60, KPM7XVUG3T20, KPM7XVUG6T40, KPM7XVUG12T8,KPM7XRUG960G, KPM7XRUG1T92, KPM7XRUG3T84, KPM7XRUG7T68, KPM7XRUG15T3.",
      "revision_history": "Fix:\n\n-  Added Garbage Collection checking in throttling parameter decision."
    },
    {
      "id": "0776b5d687d3fbafca1eb2f20fa128d1b4ec7423dcc2fefe3e9f3387ab95092f",
      "name": "Kioxia BA48 FW for PM6 drives for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "version": "BA48",
      "release_id": "NGPR2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-11T05:55:37Z",
      "released": "2022-09-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08764563M/4/SAS-Drive_Firmware_NGPR2_WN64_BA48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NGPR2",
      "size": 24171504,
      "reboot_required": false,
      "description": "Kioxia PM6 BA48 FW for model number(s) KPM6XRUG960G, KPM6XRUG1T92, KPM6XRUG3T84, KPM6XRUG7T68, KPM6XRUG15T3, KPM6XRUG30T7, KPM6XVUG800G, KPM6XVUG1T60, KPM6XVUG3T20, KPM6XVUG6T40, KPM6XVUG12T8, KPM6XMUG400G, KPM6XMUG800G, KPM6XMUG1T60, KPM6XMUG3T20.",
      "revision_history": "Fixes:\nInitial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "ee1dd07dfa56c50a22f52b957c6eea53779375c00ea310b32677d2cc45dccbfd",
      "name": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68",
      "version": "BD48",
      "release_id": "6DH0W",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-04-07T09:55:22Z",
      "released": "2023-10-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10704397M/4/SAS-Drive_Firmware_6DH0W_WN64_BD48_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6DH0W",
      "size": 24247952,
      "reboot_required": false,
      "description": "Kioxia BD48 FW for PM6 24Gbps  for model number(s) KPM6WRUG960G, KPM6WRUG1T92, KPM6WRUG3T84, KPM6WRUG7T68, KPM6WRUG15T3,KPM6WVUG960G, KPM6WVUG1T92, KPM6WVUG3T84, KPM6WVUG7T68.",
      "revision_history": "Fixes :\n- Initial Qualification of the PM6 24G SSDs. This FW fixes the run to run variation plus has tip of the library FW fixes from PM6 12G."
    },
    {
      "id": "2189d3c19f564af9c4adadb58dd81c7b80feda3edd4af1e38e757fc10724ae62",
      "name": "HGST EU46  for model number(s) HUC156030CSS200 and HUC156060CSS200",
      "version": "EU46",
      "release_id": "R39JH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T09:18:31Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12886071M/1/SAS-Drive_Firmware_R39JH_WN64_EU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R39JH",
      "size": 24103776,
      "reboot_required": false,
      "description": "This release contains firmware version EU46 FW changes to affect HGST King Cobra F 512n SAS ISE HDD, Model numbers HUC156060CSS200 and HUC156030CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "710a41520969170b139a0ad46b68638dc89b3cc9bed271ae5f33137141cd804d",
      "name": "HGST EK46 for model number(s) HUC156060CS4204",
      "version": "EK46",
      "release_id": "M04KK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T07:22:10Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12885013M/1/SAS-Drive_Firmware_M04KK_WN64_EK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M04KK",
      "size": 24112472,
      "reboot_required": false,
      "description": "This release contains firmware version EK46 'FW changes to affect HGST King Cobra F 4Kn SAS HDD, Model number HUC156060CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "be8cba2fe69053e9785264bea3fc29c4b30fe84a8cd65e095c114f2e7bbbf350",
      "name": "HGST EJ46  for model number(s) HUC156030CSS204,and HUC156060CSS204",
      "version": "EJ46",
      "release_id": "H53FC",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-20T06:20:55Z",
      "released": "2025-03-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12884528M/1/SAS-Drive_Firmware_H53FC_WN64_EJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H53FC",
      "size": 24103728,
      "reboot_required": false,
      "description": "This release contains firmware version EJ46 'FW changes to affect HGST King Cobra F 512n SAS HDD, Model numbers HUC156060CSS204 and HUC156030CSS204.\nIncludes FW change to turn off drive usage logging to avoid pointer error",
      "revision_history": "Fixes:\nFixes: FW change to turn off drive usage logging to avoid pointer error"
    },
    {
      "id": "c69c0d7de49ad38ad0c52ed4cc69e17677fb3881869c747bd9a110e6b4c8bb73",
      "name": "HGST FU46  for model number(s) HUC101830CSS200, HUC101812CSS200 and HUC101860CSS200",
      "version": "FU46",
      "release_id": "DH7TM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T11:00:24Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880083M/1/SAS-Drive_Firmware_DH7TM_WN64_FU46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DH7TM",
      "size": 24083696,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512n SAS ISE HDD, Model numbers  HUC101830CSS200, HUC101860CSS200, and HUC101812CSS200.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "cd1d62fa296afde305b57d1c8c09a670b8c62765e8c4a61a2570f61f4ffede28",
      "name": "HGST FK46 for model number(s) HUC101818CS4204 and HUC101818CS4204",
      "version": "FK46",
      "release_id": "V917M",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T10:23:21Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12880005M/1/SAS-Drive_Firmware_V917M_WN64_FK46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V917M",
      "size": 24091240,
      "reboot_required": false,
      "description": "FW changes to affect HGST Cobra F 512e and 4Kn SAS HDD , Model number HUC101818CS4204.\nIncludes FW change to turn off drive usage logging to avoid pointer error.",
      "revision_history": "Fixes:\n'FW change to turn off drive usage logging to avoid pointer error."
    },
    {
      "id": "2f758b11765da0fb1b02a4e543dc569c690272a2b0b6e0aa0bfc0776af21817b",
      "name": "HGST FJ46  for model number(s) HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204",
      "version": "FJ46",
      "release_id": "DYYN1",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2025-03-19T09:12:02Z",
      "released": "2025-03-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12879555M/1/SAS-Drive_Firmware_DYYN1_WN64_FJ46_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DYYN1",
      "size": 24083632,
      "reboot_required": false,
      "description": "This release contains FW changes to affect HGST Cobra F 512n SAS HDD, Model numbers HUC101830CSS204, HUC101812CSS204, and HUC101860CSS204 includes FW change to turn off drive usage logging to avoid pointers error.",
      "revision_history": "Fixes:\nFW change to turn off drive usage logging to avoid pointers error."
    },
    {
      "id": "5d30674b1e5fd089aee235864fdc7939bd7504f7eb23abd2ad06650abc5e6617",
      "name": "Dell Express Flash NVMe P5800x PCIe SSD Firmware Release",
      "version": "2.0.0",
      "release_id": "F63J5",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2025-03-11T17:45:55Z",
      "released": "2025-03-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12842635M/1/Express-Flash-PCIe-SSD_Firmware_F63J5_WN64_2.0.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F63J5",
      "size": 28335480,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P5800x PCIe SSD Firmware Release MR1"
    },
    {
      "id": "9919a72526e3192f77c158c625e5ec4efa06638905b3c239de5820e669db369e",
      "name": "BOSS Console Management driver for WS2022-2025",
      "version": "1.2.0.1055",
      "release_id": "7004G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-12-18T11:18:14Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11846807M/2/SAS-RAID_Driver_7004G_WN64_1.2.0.1055_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7004G",
      "size": 12936864,
      "reboot_required": false,
      "description": "BOSS Console Management driver for WS2022-2025",
      "revision_history": "Fixes: None,\nEnhancements: Console Management Driver enablement for MS Windows 2025."
    },
    {
      "id": "c5d54c034608aea2b30ae772d2f1f626db4814ccac68e55449f6043dcf90ab77",
      "name": "HGST RT09 for Vela-AP SATA ISE model number(s) HUS728T8TALE6L0",
      "version": "RT09",
      "release_id": "T0RX4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T09:40:40Z",
      "released": "2024-04-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025871M/1/Serial-ATA_Firmware_T0RX4_WN64_RT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T0RX4",
      "size": 13355792,
      "reboot_required": false,
      "description": "FW update for WDC Vela-AP 512e SATA HDD, Model number HUS728T8TALE6L0.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "5dfbeeafb4ce29aa30f615ae567aeed3c55b796b2de7aba6cc45b2f12cceca39",
      "name": "Hitachi PT09 for Vela-A ISE model number(s) HUS726T4TALA6L0",
      "version": "PT09",
      "release_id": "CWPJH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T09:13:23Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12025719M/1/Serial-ATA_Firmware_CWPJH_WN64_PT09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CWPJH",
      "size": 13487376,
      "reboot_required": false,
      "description": "'FW update for WDC Vela-A 512e SATA HDD, Model number HUS726T6TALE6L0.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "3da2d1c93d40ba01200cdc48b85bb0f0a85dcb6e489b9eaa0d9d32bcbf861b9f",
      "name": "HGST PS09 for Vela-A ISE model number(s) HUS726T6TAL4200 and HUS726T6TAL5200",
      "version": "PS09",
      "release_id": "8MJFT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-26T07:20:39Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12024641M/1/SAS-Drive_Firmware_8MJFT_WN64_PS09_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8MJFT",
      "size": 13464192,
      "reboot_required": false,
      "description": "This release contains firmware version PS09 for HGST Vela-A ISE drives - Vendor model number(s) HUS726T6TAL4200 and HUS726T6TAL5200.\n'FW update for WDC Vela-A 512e SAS HDD, Model number HUS726T6TAL5200.\nIncludes FW fixes to improve performance behavior with Patrol Reads in combination with production workload and to implement improved poor write detection.",
      "revision_history": "'- FW fix to minimize performance degradation associated with Patrol reads in combination with production workload.\n- FW modifications to implement improved Vertical Write Inhibit feature to better detect poor writes."
    },
    {
      "id": "a3327e1940b3fe3b81e47fa9d3bb7aeffd6956b5f4ee06f4a9f14c97f3c83a19",
      "name": "Samsung PM1653 drives for DSG9 FW for model numbers MZILG960HCHQAD3, MZILG1T9HCJRAD3, MZILG3T8HCLSAD3, MZILG7T6HBLAAD3 and MZILG15THBLAAD3",
      "version": "DSG9",
      "release_id": "3MV58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T17:20:50Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11939710M/1/SAS-Drive_Firmware_3MV58_WN64_DSG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3MV58",
      "size": 13264392,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count acuracy and drive temperature reporting during format operations. Firmware version DSG9 for Samsung PM1653 drives. Vendor model numbers MZILG960HCHQ-0AD3, MZILG1T9HCJR-0AD3, MZILG3T8HCLS-0AD3, MZILG7T6HBLA-0AD3, and MZILG15THBLA-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "e15c231399536e80009d372366b4e72a4c66dedf951ad1fa78d1309ab3e37961",
      "name": "Samsung PM1655 drives for FW DWG9 for model numbers MZILG800HCHQAD3, MZILG1T6HCJRAD3 and MZILG3T2HCLSAD3",
      "version": "DWG9",
      "release_id": "7MTXM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-08-06T08:00:58Z",
      "released": "2024-08-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11937657M/1/SAS-Drive_Firmware_7MTXM_WN64_DWG9_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7MTXM",
      "size": 13261200,
      "reboot_required": false,
      "description": "This update includes important reliability enhancements and also addresses issues with Max. Erase Count accuracy and drive temperature reporting during format operations. Firmware version DWG9 for Samsung PM1655 drives. Vendor model numbers MZILG800HCHQ-0AD3, MZILG1T6HCJR-0AD3, and MZILG3T2HCLS-0AD3.",
      "revision_history": "1- Corrected invalid capacity passed to Unmap API  during OPC conversion.\n2- Multiple updates to address issues found in vendor and Dell testing.\n Add features to update Max Erase Count after every Erase, and read drive temperature during drive format."
    },
    {
      "id": "baa5cac92e3b072bd227668372c2c7520ed3e15c5a55003853c701aa0df1e8a2",
      "name": "HGST J17L for model number(s) HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "version": "J17L",
      "release_id": "0NKFF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-31T05:53:56Z",
      "released": "2024-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11625826M/3/SAS-Drive_Firmware_0NKFF_WN64_J17L_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0NKFF",
      "size": 12890680,
      "reboot_required": false,
      "description": "This release contains firmware version J17L for HGST drives. Vendor model numbers HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "revision_history": "External: FW update for HGST Bear Cove MLC 3WPD SAS HDD, Model numbers HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200, HUSMR3232ASS200.\nIncludes FW fix to free space buffer calculation to avoid a potential assert condition resulting in a self-initiated reset."
    },
    {
      "id": "e304b4a3afc9985ef42898953bbb4c4c2209d80b9c683042b9eca3daf720a4c2",
      "name": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "version": "3.1.3",
      "release_id": "JTTYW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-05-28T17:47:50Z",
      "released": "2024-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11674733M/1/Express-Flash-PCIe-SSD_Firmware_JTTYW_WN64_3.1.3_A06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTTYW",
      "size": 19213864,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe PM1733a/35a FIPS Firmware Maintenance Release",
      "revision_history": "Addition of firmware update support for Dell 17th generation servers."
    },
    {
      "id": "2d691ed72b31c474544f0a9a0818d69f0e4ab820992ea73115f41143fafef850",
      "name": "WD BCQ firmware G138  for model numbers WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200,WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200,WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200",
      "version": "G138",
      "release_id": "8W5WF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T07:34:09Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11655805M/1/SAS-Drive_Firmware_8W5WF_WN64_G138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8W5WF",
      "size": 12585960,
      "reboot_required": false,
      "description": "This release contains firmware version G138 for WD BCQ drives. Vendor model numbers WUSTR6464BSS200, WUSTR6432BSS200, WUSTR6416BSS200, WUSTR6480BSS200, WUSTVA1A1BSS200, WUSTVA176BSS200, WUSTVA138BSS200, WUSTVA119BSS200, WUSTVA196BSS200, WUSTM3216BSS200, WUSTM3280BSS200, WUSTM3240BSS200.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries."
    },
    {
      "id": "13796d98c89ff1cc8cda76d598f7dfe5ccc925a8fadfd3999fb71e9fbcb079fb",
      "name": "WDC Bear Cove Quantum FIPS-140 L138 for 1WPD and 3WPD  model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205,WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "version": "L138",
      "release_id": "16C85",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-23T05:58:21Z",
      "released": "2024-05-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11654668M/1/SAS-Drive_Firmware_16C85_WN64_L138_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=16C85",
      "size": 12580296,
      "reboot_required": false,
      "description": "This release contains firmware version L138 for WDC Bear Cove Quantum FIPS-140 1WPD and 3WPD. For model numbers WUSTVA1A1BSS205, WUSTVA176BSS205, WUSTVA138BSS205, WUSTVA119BSS205, WUSTVA196BSS205, WUSTR6480BSS2005, WUSTR6416BSS205, WUSTR6432BSS205, WUSTR6464BSS205.",
      "revision_history": "- Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "ec7b4413408504ee11e7cc02edb1960d318d54ce4c0cfc3635ef7ba19403b254",
      "name": "SK HYNIX DE08 for model numbers HFS960G32FEH-7A10A, HFS1T9G32FEH-7A10A, HFS3T8G32FEH-7410A and HFS480G32FEH-7410A",
      "version": "DE08",
      "release_id": "3DTV4",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T03:52:03Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11629605M/1/Serial-ATA_Firmware_3DTV4_WN64_DE08_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3DTV4",
      "size": 13594832,
      "reboot_required": false,
      "description": "This release contains firmware version DE08 for SK HYNIX model numbers HFS960G32FEH-7A10A, HFS1T9G32FEH-7A10A, HFS3T8G32FEH-7410A and HFS480G32FEH-7410A.",
      "revision_history": "Fix: \n\n- Improvements made to Background Scanning functionality"
    },
    {
      "id": "8a52d319629e11204664327b05fd87cb5acb389f411981023123bd2d220b1dee",
      "name": "WDC/HGST Bear Cove TLC RI, SSD, 12Gbps SAS, 2.5, 512e, ISE, FW S545 for model number(s) HUSTR7648ASS200, HUSTR7696ASS200, HUSTR7619ASS200, HUSTR7638ASS200 and HUSTR7676ASS200.",
      "version": "S545",
      "release_id": "3HTHY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-08T19:57:02Z",
      "released": "2024-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11591721M/1/SAS-Drive_Firmware_3HTHY_WN64_S545_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3HTHY",
      "size": 12951728,
      "reboot_required": false,
      "description": "This release contains firmware version S545 for WDC/HGST Bear Cove TLC RI, SSD, 12Gbps SAS, 2.5, 512e, ISE.. Vendor model numbers HUSTR7648ASS200, HUSTR7696ASS200, HUSTR7619ASS200, HUSTR7638ASS200 and HUSTR7676ASS200.",
      "revision_history": "FW change to correct a free space buffer calculation error to avoid a potential assert which would result in a self-initiated reset."
    },
    {
      "id": "333f510745d6bedcbadf00dfa27e5b7532c32ae94fea09bd9ec4a93617b1329f",
      "name": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s)  KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960",
      "version": "CA0C",
      "release_id": "1YD58",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T15:53:43Z",
      "released": "2023-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10810459M/2/SAS-Drive_Firmware_1YD58_WN64_CA0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1YD58",
      "size": 12708760,
      "reboot_required": false,
      "description": "Kioxia CA0C for RM7 SAS SSD SED program for model number(s) KRM7VVUG3T84 KRM7VVUG1T92 KRM7VVUG960G KRM7VRUG7T68 KRM7VRUG3T84 KRM7VRUG1T92 KRM7VRUG960G.",
      "revision_history": "Fixes: \nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed in a different area, the drive may encounter the below failure mode. Once a drive falls into this failure mode, it cannot be recovered by power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. Data buffer is used for data transfer during Wear-Leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow.                                                                                                             Write Cache Issue: An issue that may cause firmware downloads to fail in the event of a capacitor failure. This failure is triggered by firmware download in the Write Cache Off state, and even if it occurs, it does not lead to drive failure and can be recovered by a reset or Power cycle.\nCause: When FW Update is executed in the Write Cache Off state and then restarted, capacitor discharge control is activated. In this case, unintended PLP occurs because capacitor discharge was controlled in the order of capacitor discharge and then PLP interrupt mask.\nFix: When capacitor discharge control is executed after FW Update in the Write Cache Off state and the system is restarted, the PLP interrupt mask is changed to control in the order of PLP interrupt mask and then capacitor discharge."
    },
    {
      "id": "a1178484b04285ac191ec9219242d56e944c47e79f02b74de40e05534be8c7b3",
      "name": "Seagate SBW6 for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "version": "SBW6",
      "release_id": "5G3PW",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-04-15T06:30:37Z",
      "released": "2024-04-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11496475M/1/SAS-Drive_Firmware_5G3PW_WN64_SBW6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5G3PW",
      "size": 13261504,
      "reboot_required": false,
      "description": "This release contains firmware version SBW6 Seagate for Skybolt ServoBP program for model number(s) BL600MM0069.",
      "revision_history": "Fixes:\n\n- Fix for potential drive offline during hot plug test.\n- Fix for drive hang after power cycle during cross-download testing.\n- Firmware change to fix drive assert if a seek error happens during a head switch with RAW enabled.\n- Disable Hardware DRAM Self Refresh Feature to resolve potential format corrupt issue.\n- Reduce background file update frequency to prevent possible ATI (Adjacent Track Interference).\n- Adjusted Fly Height Trigger and Long Command Completion Timeout to avoid potential read errors."
    },
    {
      "id": "c262b14586cfb8f23d28fd4fce1526b82bc29af8589298cb407fb7b8956acf5b",
      "name": "Windows Server 2022 64bit driver for PERC S140 Controller",
      "version": "5.11.0.0003",
      "release_id": "85R54",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T17:21:48Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422921M/1/SAS-RAID_Driver_85R54_WN64_5.11.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=85R54",
      "size": 6633192,
      "reboot_required": true,
      "description": "Windows Server 2022 64bit driver for PERC S140 Controller"
    },
    {
      "id": "c1ad7f22b60acedb99114f7c68abbc599cad01da466bb6ed704a1888f7280388",
      "name": "Windows Server 2019 64bit driver for PERC S140 Controller",
      "version": "5.11.0.0003",
      "release_id": "P74H3",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T17:21:17Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422918M/1/SAS-RAID_Driver_P74H3_WN64_5.11.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P74H3",
      "size": 6632656,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S140 Controller"
    },
    {
      "id": "a19fe66cfb25a5c5629b5e61e58f9149a1791a19e64f0216ecb907360c42246e",
      "name": "Dell Express Flash NVMe P4510/P4610 PCIe SSD Firmware Release",
      "version": "VDV1DP24",
      "release_id": "G99RX",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-03-07T17:22:27Z",
      "released": "2021-02-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06952022M/2/Express-Flash-PCIe-SSD_Firmware_G99RX_WN64_VDV1DP24_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G99RX",
      "size": 16774464,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe P4510/P4610 PCIe SSD Firmware Release",
      "revision_history": "Addressed issue on SMART Log Page where large number of media errors were incorrectly reported.\n Addressed issue where drive triggers critical warning 0x09 and enters read only mode when a single die goes offline"
    },
    {
      "id": "34c7cdbe33ff6937951237e4688c782c36ce0c1a9a134c21f78be30e094dd3e1",
      "name": "Dell Express Flash NVMe P5500/P5600 PCIe SSD Firmware Release",
      "version": "1.2.4",
      "release_id": "CGXH7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-03-07T15:53:46Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09999738M/2/Express-Flash-PCIe-SSD_Firmware_CGXH7_WN64_1.2.4_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CGXH7",
      "size": 17251184,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P5500/5600 PCIe SSD Firmware Release",
      "revision_history": "N/A"
    },
    {
      "id": "d86b90f28fe1d8aad0a35501f97aec38c1b7821eff4a67a08d7ebce6a14c831b",
      "name": "Samsung SM883 MU SSDR, FW  HF58. Vendor model numbers MZ7KH480HAHQ0D3, MZ7KH960HAJR0D3, MZ7KH1T9HAJR0D3, and MZ7KH3T8HALS0D3.",
      "version": "HF58",
      "release_id": "3J3JR",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-28T11:17:02Z",
      "released": "2021-04-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06950272M/3/Serial-ATA_Firmware_3J3JR_WN64_HF58_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3J3JR",
      "size": 13590256,
      "reboot_required": false,
      "description": "This release contains firmware version HF58 for vendor model numbers MZ7KH480HAHQ0D3, MZ7KH960HAJR0D3, MZ7KH1T9HAJR0D3, and MZ7KH3T8HALS0D3",
      "revision_history": "Fixes:-\n- Correct Log Addres 99h Vendor Name string from \"DELL\" to \"SAMSUNG\".\n- Disable RESTRICTED SANITIZE OVERRIDES SECURITY feature, per Dell spec.\n- Fix Pin 11 OOB Default Signal issue, where signal is returned \"High\" after repeated FW updates.\n- Other minor fixes as described in the FCN."
    },
    {
      "id": "06c6e9c9ef06b59010fc93f8b16829045acf843158062999cc017642f8b95777",
      "name": "Dell Express Flash NVMe PCIe SSD CD5 Firmware Release",
      "version": "1.2.0",
      "release_id": "T79D5",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-27T13:05:17Z",
      "released": "2021-04-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07119913M/2/Express-Flash-PCIe-SSD_Firmware_T79D5_WN64_1.2.0_A04_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T79D5",
      "size": 17054408,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD5 Firmware Release",
      "revision_history": "Fixes\nAddressed an issue where drive may asserts due to commands timing out over sideband.\nFixed issue where drive encounters an unexpected error upon committing firmware.\nFixed issue where drive reports multiple events pertaining to correctable errors.\n\nEnhancements\nN/A"
    },
    {
      "id": "54f45b3e3ed95a4734d61ae1b0410bd9bdf58b64e5d771908f77aaa00e5f2b20",
      "name": "Windows Server 2016 Driver 6.604.06.00 for PERC H330/H730/H730P/H830/H730P MX/FD33xD/FD33xS Controllers",
      "version": "6.604.06.00",
      "release_id": "T244W",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-02-19T07:08:49Z",
      "released": "2016-09-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER03940499M/11/SAS-RAID_Driver_T244W_WN64_6.604.06.00_A01_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T244W",
      "size": 6848432,
      "reboot_required": true,
      "description": "Windows Server 2016 Driver 6.604.06.00 for PERC H330/H730/H730P/H830/H730P MX/FD33xD/FD33xS Controllers",
      "revision_history": "Fixes\n- N/A\n\nEnhancements\n-  Added 1MB I/O support for H730, H730P and H830 controllers."
    },
    {
      "id": "fda7ed85944e9d8962289de66a326eff2cd94be829b58a3bdef99383702c6311",
      "name": "Toshiba EE0A for model number(s) AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "version": "EE0A",
      "release_id": "50N1P",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-13T11:38:43Z",
      "released": "2022-04-20T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08344514M/2/SAS-Drive_Firmware_50N1P_WN64_EE0A_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=50N1P",
      "size": 12543400,
      "reboot_required": false,
      "description": "This release contains firmware version EE0A for Toshiba drives. Vendor model numbers AL14SXB30ENY, AL14SXB60ENY, AL14SXB90ENY, AL14SXB30EAY, AL14SXB60EAY and AL14SXB90EAY.",
      "revision_history": "Fixes:\n- Improvements that reduce the risk of media errors"
    },
    {
      "id": "8b7171c9e267a84502b4dd3b631bc09cc0e0ab25b12cc110d8273af3b0f84615",
      "name": "Seagate 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "version": "4S0C",
      "release_id": "G04C8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-12T12:12:27Z",
      "released": "2022-07-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08459420M/2/SAS-Drive_Firmware_G04C8_WN64_4S0C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G04C8",
      "size": 12625072,
      "reboot_required": false,
      "description": "This release contains Seagate firmware version 4S0C for model number(s) XS7680SE70134, XS3840SE70134, XS1920SE70134, XS960SE70134, XS3840LE70134, XS1920LE70134 and XS960LE70134.",
      "revision_history": "Fixes:\n-Fix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\n-Fix an issue that can return corrupt data after a power cycle in a corner case.\n-Fix an issue that can return the sense code 09/80/00 to a WRITE command.\n-Fix issues that can cause command timeout.\n-Fix issues that can cause drive assert.\n-Fix issues that can cause drive hang condition.\n\nEnhancements:\n-Improve protocol spec compliance.\n-Improve throughput performance for specific workloads.\n-Improve error logging/sense data reporting.\n-\nFix an issue that can cause drive-not-ready."
    },
    {
      "id": "80bc5b2b38f5020ada30a356d65fdc93fcf66bc9bbcb353bb918d04fed7c91aa",
      "name": "BOSS-S2 Firmware",
      "version": "2.5.13.4008",
      "release_id": "MVC3P",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-12T09:19:45Z",
      "released": "2020-07-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06357157M/4/SAS-RAID_Firmware_MVC3P_WN64_2.5.13.4008_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MVC3P",
      "size": 6585424,
      "reboot_required": true,
      "description": "BOSS-S2 ROM version 2.5.13.4008",
      "revision_history": "Fixes : None\nEnhancements :Signed Binaries"
    },
    {
      "id": "dc4d9b31b476ffc086c28441a7060b994ff12bd8c7791266534a46aca19bec06",
      "name": "Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "version": "B02A",
      "release_id": "CPP97",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-12T04:37:43Z",
      "released": "2024-02-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11252185M/1/SAS-Drive_Firmware_CPP97_WN64_B02A_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CPP97",
      "size": 12644544,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "revision_history": "Fixes: \n\nFix1:  \n- A) When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  B) FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.                                                                                                                                                                              \nFix 2:\n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\nFix 3:\n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "6015e77f9438cdd754023cfda5871ba7de0e5e38b506d86bb975cbaaa88f5b36",
      "name": "Dell Express Flash NVMe P4500/P4600 PCIe SSD Firmware Release",
      "version": "QDV1DP17",
      "release_id": "CR0HC",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T21:34:56Z",
      "released": "2020-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06533230M/2/Express-Flash-PCIe-SSD_Firmware_CR0HC_WN64_QDV1DP17_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CR0HC",
      "size": 16645544,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe P4500/P4600 PCIe SSD Firmware Release"
    },
    {
      "id": "2b778bf7fdc239c077dc71367aad311fb6a2d15816fc43bf2c13899855ec3377",
      "name": "Non-expander Storage Backplane Firmware",
      "version": "4.35",
      "release_id": "VV85D",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T15:17:23Z",
      "released": "2019-08-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05772283M/10/Firmware_VV85D_WN64_4.35_A00_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VV85D",
      "size": 24118960,
      "reboot_required": true,
      "description": "Dell SEP Firmware for PowerEdge Servers with passive backplanes",
      "revision_history": "Firmware 4.35\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms/configurations.\n\n\n\nChange History:\n\nFirmware 4.32\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.29\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.27\nFixes:\n- Addressed minor bug related to NVMe device reporting\nEnhancements:\n- None\n\nFirmware 4.26\nFixes:\n- Addressed incorrect cable error reporting for PowerEdge R520 x12 passive backplane\nEnhancements:\n- Added new RAID controller support for PowerEdge R740XD 24x2.5\" NVMe backplane\n- Added supported for NVMe only configurations in PowerEdge R6425 10x2.5\" backplane\n\nFirmware 4.23\nFixes:\n- Addressed an issue with firmware roll-back when HBA controller is present.\nEnhancements:\n- Added support for NVMe drive type detect in supported backplanes.\n\nFirmware 4.18\nFixes:\n- None\nEnhancements:\n- Added drive LED management capability for SATA chipset connect configurations.\n- Added ability to report NVMe drive presence for system power and thermal management.\n\nFirmware 4.17\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.04\nFixes:\n- Addressed fixed Bay ID reporting in all NVMe drive configurations\nEnhancements:\n- None\n\nFirmware 3.62\nFixes:\n- Addressed potential backplane personality detection issue\nEnhancements:\n- None\n\nFirmware 3.58\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 3.56\n- Initial Release"
    },
    {
      "id": "9431d253a03a2caca577166cfc03127602ee59a930310d0e3511af1aca6a0b67",
      "name": "Dell Express Flash NVMe PCIe SSD CD7 U.2 OPAL Firmware Maintenance Release",
      "version": "1.0.1",
      "release_id": "XRT9C",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T04:54:35Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09992794M/2/Express-Flash-PCIe-SSD_Firmware_XRT9C_WN64_1.0.1_A02_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XRT9C",
      "size": 18341424,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD7 U.2 OPAL Firmware Release",
      "revision_history": "Fixes:\nN/A\n\nEnhancements:\nAdded PERC 12 Support"
    },
    {
      "id": "3b764d1917ceefc3992a34fb936d2458b1dfd4ea153d4f5f4479e2695234114e",
      "name": "Dell Express Flash NVMe PCIe SSD CD7 U.2 ISE Firmware Release",
      "version": "2.0.1",
      "release_id": "K6597",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T04:46:16Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09992830M/2/Express-Flash-PCIe-SSD_Firmware_K6597_WN64_2.0.1_A02_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K6597",
      "size": 18137576,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD7 U.2 ISE Firmware Release",
      "revision_history": "Fixes:\nN/A\n\nEnhancements:\nAdded PERC 12 Support"
    },
    {
      "id": "64fd31f1e093836e48d5c599c45017e35d30aa8c1b93b6377a9fd010062dd0d0",
      "name": "Dell Express Flash NVMe PCIe SSD CD6 Firmware Release",
      "version": "2.1.6",
      "release_id": "7NY55",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T03:55:31Z",
      "released": "2021-07-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07498628M/2/Express-Flash-PCIe-SSD_Firmware_7NY55_WN64_2.1.6_A01_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7NY55",
      "size": 17669056,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD CD6 Firmware Release",
      "revision_history": "Fixes:\n- Timer adjustment was made with respect to Interrupt Coalescing.\n- Fix applied not to do unexpected memory access when receiving MCTP over PCIe commands.\n- Fixes related to Get Log Page command with more than 4KB transfer was made over NVMe-MI.\n- Fixes related to reporting correct FW version was applied in Persistent Event Log event.\n- Fixes related to process unmap command was made to non existent Namespace to avoid LBA mismatch.\n- Timer for LBA Status Information was adjusted to update re-starts at the executing of GetLog Page command.\n- PLP fix was applied in order to judge the object correctly in restoring the data from the emergency evacuation area.\n- Fixes related to reset was applied not to detect a contradiction when Drive received Reset command during writing last sector of 256KiB in Atomic Write process at Power off.\n\nEnhancement:\n- NVMe-MI"
    },
    {
      "id": "ff41d21c313732526a71ede4f99d557f20547a192ee8a67aa5f50331af23a0f4",
      "name": "Dell Express Flash NVMe P4800X PCIe SSD Firmware Release",
      "version": "E201DP38",
      "release_id": "HMRK7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-02T20:56:27Z",
      "released": "2023-04-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09855603M/2/Express-Flash-PCIe-SSD_Firmware_HMRK7_WN64_E201DP38_A07_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=HMRK7",
      "size": 16766376,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe P4800X PCIe SSD Firmware Release",
      "revision_history": "N/A"
    },
    {
      "id": "adcdd14657ff15c5609da1a3bb478ca3f37b2bf3a1c019cba77db446f7b8f00b",
      "name": "Toshiba DBC4 for model number(s) KHK6YRM8240G, KHK6YRM8480G, KHK6YRSE480G, KHK6YRSE960G, KHK6YRSE1T92, KHK6YRSE3T84, KHK6YRSE7T68, KHK6YVSE480G, KHK6YVSE960G, KHK6YVSE1T92, KHK6YVSE3T84.",
      "version": "DBC4",
      "release_id": "W0YR1",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-02T06:44:59Z",
      "released": "2020-06-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06255401M/3/Serial-ATA_Firmware_W0YR1_WN64_DBC4_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=W0YR1",
      "size": 12622472,
      "reboot_required": false,
      "description": "This release contains firmware version DBC4 for Toshiba drives. Vendor model numbers KHK6YRM8240G, KHK6YRM8480G, KHK6YRSE480G, KHK6YRSE960G, KHK6YRSE1T92, KHK6YRSE3T84, KHK6YRSE7T68, KHK6YVSE480G, KHK6YVSE960G, KHK6YVSE1T92, KHK6YVSE3T84.",
      "revision_history": "Fixes:\n- Fixed error found during Write Uncorrectable testing that reported 07/27/00 instead of 03/11/00.\nEnhancements:\n- Added Pin 11 OOB Temperature reporting capability per ENG0015386 A04.\n- Performance improvements on Random Read and Write."
    },
    {
      "id": "04c1b0629a67a3f4cb7f521f2c0e24758db57c0f75367363cf342366a3149630",
      "name": "Dell PowerEdge Express Flash Ent NVMe AGN SED Firmware Release",
      "version": "1.5.0",
      "release_id": "610WN",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:42:11Z",
      "released": "2023-12-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10871637M/2/Express-Flash-PCIe-SSD_Firmware_610WN_WN64_1.5.0_A06_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=610WN",
      "size": 21649848,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe AGN SED Firmware Release",
      "revision_history": "Fixes:\n\n1. Improved Persistent Event Log behavior.\n2. Improved management interface responsiveness VDM command handling.\n3. Improved temperature reporting.\n\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "17d32c474894380a62ddc1069b6710fa5986fac584390d91f063c236fb97aea9",
      "name": "Dell PowerEdge Express Flash Ent NVMe AGN Firmware Release",
      "version": "2.5.0",
      "release_id": "5CM3G",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:38:47Z",
      "released": "2023-12-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10871579M/3/Express-Flash-PCIe-SSD_Firmware_5CM3G_WN64_2.5.0_A06_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5CM3G",
      "size": 21646664,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. Improved Persistent Event Log behavior.\n2. Improved management interface responsiveness VDM command handling.\n3. Improved temperature reporting.\n\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "d31a2b80867c52171a4c1e341a06b8297f7e871256099e506254c6a5c135d640",
      "name": "Dell PowerEdge Express Flash Ent NVMe v2 FIPS AGN Maintenance Firmware Release",
      "version": "3.5.0",
      "release_id": "2VG67",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:37:22Z",
      "released": "2023-11-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10824098M/2/Express-Flash-PCIe-SSD_Firmware_2VG67_WN64_3.5.0_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2VG67",
      "size": 21774520,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe v2 FIPS AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. NVMe-MI improvements.\n2. Persistent Event Log improvements.\n3. Fixed inssue with firmware update over NVMe-MI\n4. Drive becomes unresponsive after a reboot when TCG commands are outstanding.\n5. Corrected reported shutdown timeout values for 3.84TB, 6.4TB and 7.68TB capacity drives.\n\n\nEnhancements:\n\n1. Media access over sideband improvements.\n2. Enable Relaxed Ordering."
    },
    {
      "id": "d3068e476ab86d35d740df46573b012a443c549c62d3faca73aff63257f9e5fa",
      "name": "Dell PowerEdge Express Flash Ent NVMe v2 AGN Maintenance Firmware Release",
      "version": "2.5.0",
      "release_id": "5V3P7",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T19:37:00Z",
      "released": "2023-11-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10823865M/2/Express-Flash-PCIe-SSD_Firmware_5V3P7_WN64_2.5.0_A05_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5V3P7",
      "size": 21761944,
      "reboot_required": false,
      "description": "Dell PowerEdge Express Flash Ent NVMe v2 AGN Firmware Release",
      "revision_history": "Fixes:\n\n1. NVMe-MI improvements.\n2. Persistent Event Log improvements.\n3. Fixed inssue with firmware update over NVMe-MI\n4. Drive becomes unresponsive after a reboot when TCG commands are outstanding.\n5. Corrected reported shutdown timeout values for 3.84TB, 6.4TB and 7.68TB capacity drives.\n\n\nEnhancements:\n\n1. Media access over sideband improvements.\n2. Enable Relaxed Ordering."
    },
    {
      "id": "07d12a17a86dc38111d4451c8f0fb3ff6307bf851b212da18a1048c0fe56b499",
      "name": "Dell PowerEdge Express Flash Ent NVMe PE8010 SED Maintenance Firmware Release",
      "version": "1.2.0",
      "release_id": "7V81K",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T15:30:11Z",
      "released": "2023-06-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10103228M/2/Express-Flash-PCIe-SSD_Firmware_7V81K_WN64_1.2.0_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7V81K",
      "size": 20151960,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash Ent NVMe PE8010 SED Firmware Release",
      "revision_history": "PERC 12.1 support added."
    },
    {
      "id": "fcedf881f952e18cb7886f5bae15f0f5b345a33ba459c4e4e6004394bc50777b",
      "name": "Dell PowerEdge Express Flash Ent NVMe PE8010 Firmware Release",
      "version": "1.3.0",
      "release_id": "T1XKD",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-01T15:24:28Z",
      "released": "2023-08-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10443052M/3/Express-Flash-PCIe-SSD_Firmware_T1XKD_WN64_1.3.0_A04_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T1XKD",
      "size": 19878392,
      "reboot_required": false,
      "description": "Dell EMC PowerEdge Express Flash Ent NVMe PE8010 Firmware Release",
      "revision_history": "Fixes:\n\n1. Corrected LED behavior to adhere to LED specifications\n\nEnhancements:\n\nN/A"
    },
    {
      "id": "a62cf8b6040c3af38844b03634d1e0c492420b94c03ac7b4dbc5a750a5c78d19",
      "name": "Dell Express Flash NVMe PCIe SSD PM1725a Firmware Release",
      "version": "1.2.1",
      "release_id": "34C36",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-30T17:17:43Z",
      "released": "2021-02-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07036198M/3/Express-Flash-PCIe-SSD_Firmware_34C36_WN64_1.2.1_A06_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=34C36",
      "size": 18653896,
      "reboot_required": true,
      "description": "Dell Express Flash NVMe PCIe SSD PM1725a firmware release",
      "revision_history": "Fixes:\n1. Fixed to guarantee LOC retry Q processing within a certain time.\n2. Added one semaphore to lock the access of SFR \u0026 Applied the semaphore to all cores where we have synchronization problem\n3. Assert during VPD reads fix with FW change that resolves contention to ensure that the variable is no longer affected by the resource contention issue.  \n4. Fixed reset check in reservation bring up path to prevent initialization due to NSSR.  After this change the Reservation is retained.\n5. Disable arbitration at the beginning of NSSR so that no invalid status are sent to the host while NSSR is being processed.\n6. Applied enhanced NAND recovery algorithm to prevent read UECC error\n\nEnhancements:\nN/A"
    },
    {
      "id": "56088825928a2490073d1688903d8e778f901b211ac34920f33b72d7d3c6b33f",
      "name": "Dell Express Flash NVMe PCIe SSD PM1725b Firmware Release",
      "version": "1.2.1",
      "release_id": "JXWJW",
      "category": "Express Flash PCIe SSD",
      "category_slug": "express-flash-pcie-ssd",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-30T17:14:38Z",
      "released": "2020-10-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06652670M/2/Express-Flash-PCIe-SSD_Firmware_JXWJW_WN64_1.2.1_A03_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JXWJW",
      "size": 18945960,
      "reboot_required": false,
      "description": "Dell Express Flash NVMe PCIe SSD PM1725b firmware release",
      "revision_history": "Bug Fixes:\n1. If the command is moved to LOC retry Q and it is not processed for a certain period of time(32ms), stop processing the new command and process the command of LOC retry Q\n2. The priority if given to the Format command to allow it to complete.  Hence while a format operation is going on the FW will not log unrelated commands timeout. \n3. Correct the search function to find the correct abort command used to abort another command.\n4. The FW change resolves this contention to ensure that this variable is no longer affected by the resource contention issue.  \n5. This change will bypass RO mode and allow the drive to continue normal bringup.  The internal error log file will be re-written at the next error the host is notified on.  \n6. Fixed reset check in reservation bring up path to prevent initialization due to NSSR.  After this change the Reservation is retained."
    },
    {
      "id": "0b31c8b898ed59bbe95d33ddc5569a0c7e8b081e311d48266f1880ad78149d26",
      "name": "Samsung PM883 RI SSDR, FW HE59 for model number(s) MZ7LH7T6HMLA0D3, MZ7LH240HAHQ0D3, MZ7LH3T8HMLT0D3, MZ7LH480HAHQ0D3, MZ7LH960HAJR0D3, MZ7LH1T9HMLT0D3",
      "version": "HE59",
      "release_id": "93P7P",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T14:10:28Z",
      "released": "2021-04-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06949454M/3/Serial-ATA_Firmware_93P7P_WN64_HE59_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=93P7P",
      "size": 13454032,
      "reboot_required": false,
      "description": "This release contains firmware version HE59 for Samsung PM883 RI SSDR,  for model number(s) MZ7LH7T6HMLA0D3, MZ7LH240HAHQ0D3, MZ7LH3T8HMLT0D3, MZ7LH480HAHQ0D3, MZ7LH960HAJR0D3, MZ7LH1T9HMLT0D3",
      "revision_history": "Fixes:-\n- Correct Log Addres 99h Vendor Name string from \"DELL\" to \"SAMSUNG\".\n- Disable RESTRICTED SANITIZE OVERRIDES SECURITY feature, per Dell spec.\n- Fix Pin 11 OOB Default Signal issue, where signal is returned \"High\" after repeated FW updates.\n- Other minor fixes as described in the FCN.\nEnhancements:\n-N/A"
    },
    {
      "id": "b555e039474597e95f58335c912d0276633df1089499675842744e0e344b31eb",
      "name": "MICRON 5200 RI/ MU  SATA \u0026apos;F005\u0026apos; FW for model number(s) MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, MTFDDAK1T9TDN, MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD.",
      "version": "F005",
      "release_id": "W2X8N",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T09:43:52Z",
      "released": "2022-04-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11196038M/1/Serial-ATA_Firmware_W2X8N_WN64_F005_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=W2X8N",
      "size": 12468256,
      "reboot_required": false,
      "description": "This release contains Micron firmware F005 for models MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD, MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, and MTFDDAK1T9TDN for all operating systems.",
      "revision_history": "Fixes:\n-F004 FW had a corner case failure mode when a read command is sent followed by large write command.  The internal logic to manage command priority had a bug causing the drive to issue a com-reset.  In F005 this logic was corrected and the internal logic for managing command priority was working as expected.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "c0c35ec567586d3e598e838a175f119121b72445109dbe8bf5b5795acfdf074a",
      "name": "Intel DL6R  for model number(s) SSDSCKKB240G8R, SSDSCKKB480G8R, SSDSCKKB960G8R.",
      "version": "DL6R",
      "release_id": "Y1P10",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-30T09:29:44Z",
      "released": "2020-09-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06303847M/2/Serial-ATA_Firmware_Y1P10_WN64_DL6R_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=Y1P10",
      "size": 12056704,
      "reboot_required": false,
      "description": "This release contains firmware version DL6R for Intel drives. Vendor model numbers  SSDSCKKB240G8R, SSDSCKKB480G8R, SSDSCKKB960G8R.",
      "revision_history": "Fixes:\n-SMART attribute shift solution\n-MRR settings to mitigate BJ004 issue\n-Fixes an issue where drive stops responding after soft-reboot following windows install\n\nEnhancements:\nN/A"
    },
    {
      "id": "eeb214c6eeee69a5f0df9a8a636c9e2cb91affb59cdc9a3d676d62028dad541d",
      "name": "Micron K803 for 5400 SATA model number(s) MTFDDAK7T6TGA",
      "version": "K803",
      "release_id": "333Y2",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-30T06:44:45Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606516M/2/Serial-ATA_Firmware_333Y2_WN64_K803_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=333Y2",
      "size": 12359152,
      "reboot_required": false,
      "description": "This release contains firmware version K803 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK7T6TGA",
      "revision_history": "Fixes:\n- Fixes to address performance."
    },
    {
      "id": "6c992026ccb1034e5d76c43933dc44c2595da3c48f49b380535843c14de95847",
      "name": "Micron K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "version": "K003",
      "release_id": "RJ0WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T14:41:30Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606437M/2/Serial-ATA_Firmware_RJ0WY_WN64_K003_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJ0WY",
      "size": 12627936,
      "reboot_required": false,
      "description": "This release contains firmware version K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "revision_history": "Fixes:\n\n-Fixes to address performance."
    },
    {
      "id": "7f5691c4430c7327b0a80ce3ef83995daadc50336c7a6a3a67edf9b560b1db34",
      "name": "Micron K403 for 5400 SATA model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB",
      "version": "K403",
      "release_id": "JTW3W",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T06:58:14Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606566M/2/Serial-ATA_Firmware_JTW3W_WN64_K403_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JTW3W",
      "size": 12364032,
      "reboot_required": false,
      "description": "This release contains firmware version K403 for Micron 5400 SATA ISE drives - Vendor model number(s) MTFDDAK3T8TGA and MTFDDAK3T8TGB.",
      "revision_history": "Fixes:\n\n- Fixes to address performance."
    },
    {
      "id": "00468fc0260e621a877723a344475d07853b33dfb806cc08c1add6b63e2f522d",
      "name": "Samsung DSLA for model number(s) MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "version": "DSLA",
      "release_id": "XNGNT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-24T07:44:11Z",
      "released": "2020-09-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06510985M/4/SAS-Drive_Firmware_XNGNT_WN64_DSLA_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XNGNT",
      "size": 12464696,
      "reboot_required": false,
      "description": "This release contains firmware version DSLA for Samsung drives. Vendor model numbers MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "revision_history": "Fixes:\n - Incorrect Metadata returned after power cycle\n - UECC report but normal cell distribution\n - PLP Fail During Write Same"
    },
    {
      "id": "b601ecce804aadbaa077403eef3e0423412e341361f6a509c27d184516de9a35",
      "name": "HGST LT21  for model number(s) HGST HUH721008ALE600, HGST HUH721010ALE600.",
      "version": "LT21",
      "release_id": "H12N2",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T17:46:19Z",
      "released": "2021-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07861656M/2/Serial-ATA_Firmware_H12N2_WN64_LT21_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H12N2",
      "size": 12987416,
      "reboot_required": false,
      "description": "This release contains firmware version LT21  for HGST drives. Vendor model numbers HGST HUH721008ALE600, HGST HUH721010ALE600.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "7d98bb95a79ce046742b0e7a9a29f34daca02fb5fe008896efcc9775bdddcafc",
      "name": "HGST KV45  for model number(s) HGST HUS726020ALA610 and HGST HUS726040ALA610.",
      "version": "KV45",
      "release_id": "X59KC",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-23T17:40:36Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150839M/2/Serial-ATA_Firmware_X59KC_WN64_KV45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X59KC",
      "size": 12403400,
      "reboot_required": false,
      "description": "This release contains the firmware revision HGST KV45  for Aries K Plus drive model number(s) HGST HUS726020ALA610 and HGST HUS726040ALA610.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "6086d29b5463ccc9116bcc3ac5e5af91b5d6d7d0aa8af5cf40661d0308027280",
      "name": "Intel DL5C for model number(s) SSDSC2KB240G7R, SSDSC2KB480G7R, SSDSC2KB960G7R, SSDSC2KB019T7R, SSDSC2KB038T7R, SSDSC2KG240G7R, SSDSC2KG480G7R, SSDSC2KG960G7R, SSDSC2KG019T7R.",
      "version": "DL5C",
      "release_id": "V141M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T17:20:47Z",
      "released": "2019-12-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05840715M/2/Serial-ATA_Firmware_V141M_WN64_DL5C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V141M",
      "size": 11710864,
      "reboot_required": false,
      "description": "This release contains firmware version DL5C for Intel drives. Vendor model numbers SSDSC2KB240G7R, SSDSC2KB480G7R, SSDSC2KB960G7R, SSDSC2KB019T7R, SSDSC2KB038T7R, SSDSC2KG240G7R, SSDSC2KG480G7R, SSDSC2KG960G7R, SSDSC2KG019T7R.\n\n*Power cycle is required if you update the firmware from DL58 to this one.",
      "revision_history": "Fixes:\nAddresses a critical security FW issue that can result in unathorized access the user data after a secure erase\nEnhancements:\nTelemetry 2.0 implementation"
    },
    {
      "id": "80a011214392c519c007d21d27f233067d9ec9dd23b409c40945150e7d60bab6",
      "name": "Toshiba DBB2 for model number(s) KHK6UVSE480G, KHK6UVSE960G, KHK6UVSE1T92, KHK6UVSE3T84,KHK6URSE480G, KHK6URSE960G, KHK6URSE1T92, KHK6URSE3T84, KHK6URSE7T68.",
      "version": "DBB2",
      "release_id": "68MF7",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T17:10:07Z",
      "released": "2020-05-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06259865M/2/Serial-ATA_Firmware_68MF7_WN64_DBB2_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=68MF7",
      "size": 12559112,
      "reboot_required": false,
      "description": "Initial release of firmware version DBB2 to support Toshiba Hawk 6 SED models KHK6URSE480G, KHK6URSE960G, KHK6URSE1T92, KHK6URSE3T84, KHK6URSE7T68, KHK6UVSE480G, KHK6UVSE960G, KHK6UVSE1T92, and KHK6UVSE3T84.",
      "revision_history": "Fixes:\n-'07/27/00' Bug fix that was requested \n-Pin 11 updates for the A04 specification\n-IO performance increases all capacities\n-TCG Band count change\nEnhancements:\n-N/A"
    },
    {
      "id": "677e3a67b1c439fdecfba818e628b71070c6c8cd014d8ffde7fd59542c47a6d2",
      "name": "Samsung DWLA for model number(s) MZILS400HEGR0D3, MZILS800HEHP0D3, MZILS1T6HEJH0D3 and MZILS3T2HMLH0D3.",
      "version": "DWLA",
      "release_id": "K53JY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-23T15:58:32Z",
      "released": "2020-08-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06462498M/3/SAS-Drive_Firmware_K53JY_WN64_DWLA_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K53JY",
      "size": 12040464,
      "reboot_required": false,
      "description": "This release contains firmware version DWLA for Samsung drives. Vendor model numbers MZILS400HEGR0D3, MZILS800HEHP0D3, MZILS1T6HEJH0D3 and MZILS3T2HMLH0D3.",
      "revision_history": "Fixes:\n - Incorrect Metadata returned after power cycle\n - UECC report but normal cell distribution\n - PLP Fail During Write Same"
    },
    {
      "id": "d0c7958e2db41a378a45dea89a33b1da584e47097bf4dc0ae52d469ebd6efa7d",
      "name": "Micron SED J408 firmware for model number(s) MTFDDAK3T8TDS and MTFDDAK3T8TDT",
      "version": "J408",
      "release_id": "VX44T",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T13:37:47Z",
      "released": "2023-09-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10427733M/2/Serial-ATA_Firmware_VX44T_WN64_J408_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VX44T",
      "size": 12304552,
      "reboot_required": false,
      "description": "This release contains firmware version J408 for Micron SED family of drives (3.84TB capacity). Drive model numbers MTFDDAK3T8TDS and MTFDDAK3T8TDT.",
      "revision_history": "Fixes:\n\n- Fixes for FW assert issue and power loss handeling issue."
    },
    {
      "id": "0f2aad04e3d715fe60af5cb8dca609f6a76e3d07ca5f0ab96be68d1f12b515a0",
      "name": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "version": "B326",
      "release_id": "7FV43",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T11:30:04Z",
      "released": "2024-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11166204M/1/SAS-Drive_Firmware_7FV43_WN64_B326_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7FV43",
      "size": 12699824,
      "reboot_required": false,
      "description": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "revision_history": "Fixes: \n\nFix1:  \n- When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  Fixed FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.\n                                                                                                                                                                                   \nFix 2: \n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\n\nFix 3: \n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "43da4fa3e46839dfa4494884323fbe63d1a7b0b55e614d1248d5f5fb5c3a1640",
      "name": "Micron J408 for the model number(s)MTFDDAK3T8TDS and MTFDDAK3T8TDT .",
      "version": "J408",
      "release_id": "R9YDC",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:49:13Z",
      "released": "2023-09-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10270252M/2/Serial-ATA_Firmware_R9YDC_WN64_J408_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R9YDC",
      "size": 11675960,
      "reboot_required": false,
      "description": "This release contains firmware version J408 for Micron drives. Vendor model numbers MTFDDAK3T8TDS and MTFDDAK3T8TDT.",
      "revision_history": "Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "e476ba88da356bad67538ce06e54a64af28ea4c555ed2c8163226e0f77f448f0",
      "name": "Micron J008 SED firmware for model numbers MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS, MTFDDAK480TDT, MTFDDAK960TDT, and MTFDDAK1T9TDT.",
      "version": "J008",
      "release_id": "CX0H8",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:48:55Z",
      "released": "2023-09-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10433741M/2/Serial-ATA_Firmware_CX0H8_WN64_J008_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CX0H8",
      "size": 11680080,
      "reboot_required": false,
      "description": "This release contains firmware version J008 for Micron SED RI  and MU family of drives (capacities of 1.92TB and lower). Drive model numbers MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS, MTFDDAK480TDT, MTFDDAK960TDT, and MTFDDAK1T9TDT.",
      "revision_history": "Fixes:\n-Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "76b7116270b3cd4c1c9c86222e1f499696f02117527805b4d018abad824073c8",
      "name": "Intel Youngsville refresh DL6B for model number(s). SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R",
      "version": "DL6B",
      "release_id": "4DW70",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:45:55Z",
      "released": "2023-12-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10541168M/2/Serial-ATA_Firmware_4DW70_WN64_DL6B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4DW70",
      "size": 11740528,
      "reboot_required": false,
      "description": "This release contains firmware version DL6B for Intel drives. Vendor model numbers  SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R.",
      "revision_history": "Fixes:\n\n-  Fix for SMART attribute failure observed at power up.\n-  Fix for IO timeouts resulting in device failures."
    },
    {
      "id": "475ac4126fa9bb1e01ce89ec94b557fca46eeac84609b5a56a26ffd9b9a42d53",
      "name": "Toshiba DABB for model number(s) THNSF8120PCSE, THNSF8240PCSE, THNSF8480PCSE, THNSF8960PCSE, THNSF81Q92CSE, THNSF8200PCSE, THNSF8400PCSE, THNSF8800PCSE and THNSF81Q60CSE.",
      "version": "DABB",
      "release_id": "6JJWV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:43:47Z",
      "released": "2018-08-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04988004M/3/Serial-ATA_Firmware_6JJWV_WN64_DABB_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6JJWV",
      "size": 11268608,
      "reboot_required": false,
      "description": "This release contains firmware version DABB for Toshiba drives. Vendor model numbers THNSF8120PCSE, THNSF8240PCSE, THNSF8480PCSE, THNSF8960PCSE, THNSF81Q92CSE, THNSF8200PCSE, THNSF8400PCSE, THNSF8800PCSE and THNSF81Q60CSE.",
      "revision_history": "Fixes\n-The drive hangs up if many data writes take place in the same LBA area with multiple threads. The firmware bug is fixed.\n-FTL refresh start running as a background task if FTL table stays unchanged for 1,000 hours. The FTL refresh, however, causes user command delay because it's prioritized. When many FTL blocks are refreshed at a time, timeout is detected by a host system. To prevent a timeout, the FTL refresh is eliminated.\n\nEnhancements\nn/a"
    },
    {
      "id": "5086e78dc030867d4946fe97008ff36bf0257aa011025b9bd1e283a60cc72e2d",
      "name": "Samsung PM1645a drive for FW DWA4 for Model number(s):MZILT800HBHQ0D3, MZILT1T6HBJR0D3, MZILT3T2HBLS0D3.",
      "version": "DWA4",
      "release_id": "VJY6V",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:39:09Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08613033M/2/SAS-Drive_Firmware_VJY6V_WN64_DWA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VJY6V",
      "size": 11323344,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1645a drive for Model number(s):MZILT800HBHQ0D3, MZILT1T6HBJR0D3, MZILT3T2HBLS0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "35eac7069698f618d06d9c9ea299c75e9b17bddc06457ca22fb16eb38e38a7d9",
      "name": "Samsung DSF8 for model number(s) MZILT960HAHQ0D3, MZILT1T9HAJQ0D3, MZILT3T8HALS0D3, MZILTZ7T6HMLA0D3, and MZILT15HMLA0D3.",
      "version": "DSF8",
      "release_id": "J3RRK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:14:50Z",
      "released": "2021-01-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06899246M/2/SAS-Drive_Firmware_J3RRK_WN64_DSF8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J3RRK",
      "size": 11483448,
      "reboot_required": false,
      "description": "This release contains firmware version DSF8 for Samsung drives. Vendor model numbers MZILT960HAHQ0D3, MZILT1T9HAJQ0D3, MZILT3T8HALS0D3, MZILTZ7T6HMLA0D3, and MZILT15HMLA0D3."
    },
    {
      "id": "261ba63129d1f41b2914071e82cd4a6a82940967e80d3d8e61f5f08155c4a3a8",
      "name": "HGST LS21 for model number(s) HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.",
      "version": "LS21",
      "release_id": "MGW91",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:28Z",
      "released": "2021-11-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07861414M/2/SAS-Drive_Firmware_MGW91_WN64_LS21_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MGW91",
      "size": 12336240,
      "reboot_required": false,
      "description": "This release contains firmware version LS21 for HGST drives. Vendor model numbers HUH721008AL5200, HUH721008AL4200, HUH721010AL5200 and HUH721010AL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "5e79a0ae39f437434e9bd58784c7071caaee4797b0d14a175c5a54b2c9ca82d3",
      "name": "Seagate KT3C for model number(s) ST900MP0026, ST600MP0036 and ST300MP0026",
      "version": "KT3C",
      "release_id": "JMP8Y",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:10:11Z",
      "released": "2023-08-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10267689M/2/SAS-Drive_Firmware_JMP8Y_WN64_KT3C_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JMP8Y",
      "size": 12327328,
      "reboot_required": false,
      "description": "Firmware Refresh for Segate Kestrel 512n ISE.  Model Numbers ST900MP0026, ST600MP0036, ST300MP0026.\nFix FW to address drive not ready and self test issues.",
      "revision_history": "- Fix for potential drive-not-ready during boot up.\n- Fix for drive reporting incorrect progress on extended background self test."
    },
    {
      "id": "121c2c65e1e9a03b00d25ba579c34f484234d576609fe0ed7e6c5860d47a0e0b",
      "name": "Samsung PM1643a drives for FW DSA4 for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "version": "DSA4",
      "release_id": "D7RNT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:05:17Z",
      "released": "2022-07-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08612628M/2/SAS-Drive_Firmware_D7RNT_WN64_DSA4_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D7RNT",
      "size": 11328112,
      "reboot_required": false,
      "description": "This FW belongs to Samsung PM1643a drives for model numbers:MZILT960HBHQ0D3, MZILT1T9HBJR0D3, MZILT3T8HBLS0D3, MZILT7T6HALA0D3, MZILT15THALA0D3.",
      "revision_history": "Fixes:\n- Fix for Interval Read caused Read Disturb UECC\n- Add SRAM Recovery count to Log Page 2Fh\n- Applied NM SRAM Refresh W/A\n- Applied NM SRAM Recovery W/A\n- Update Logical Unit Failure Sense Code"
    },
    {
      "id": "c3fa3bfa4a100d08fcfd210bbb17970e2f94364f62672e9c9ed24ddf6eba2cee",
      "name": "Seagate KSCC for model number(s) ST900MP0126",
      "version": "KSCC",
      "release_id": "MG6NK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-22T13:04:43Z",
      "released": "2023-10-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09833994M/2/SAS-Drive_Firmware_MG6NK_WN64_KSCC_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MG6NK",
      "size": 12280816,
      "reboot_required": false,
      "description": "Firmware Refresh for Seagate Kestrel 512n FIPS. Model Number ST900MP0126.\nFix FW to address drive not ready and self test issues.",
      "revision_history": "- Fix for potential drive-not-ready during boot up.\n- Fix for drive reporting incorrect progress on extended background self test."
    },
    {
      "id": "f9290eb3b74efc450be944a10ae52b87ef4989382da72c3cd6b1a85e58859631",
      "name": "Seagate 3D03  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "version": "3D03",
      "release_id": "NKGWD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:03:59Z",
      "released": "2022-12-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09072701M/2/SAS-Drive_Firmware_NKGWD_WN64_3D03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKGWD",
      "size": 11993080,
      "reboot_required": false,
      "description": "This release contains firmware version 3D03 Seagate  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "revision_history": "Fixes:\nFix the drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can make the drive return 0B/44 to all commands until power cycled.\nFix issues that can cause drive assert.\nFix issues that can cause command timeout.\nFix issues that can cause drive-not-ready, including the case that can happen after power-cycle.\nFix issues that can cause drive hang condition.\nEnhancements:\nImprove error logging/sense data reporting."
    },
    {
      "id": "a08ca9a1bf4c85e589749c6ee784bef8f7efcf512afb12fbf2b0b1ffc38c6da7",
      "name": "Toshiba AS10 for model number(s) PX05SMB320Y, PX05SMB160Y, PX05SMB080Y, PX05SMB040Y, PX05SVB384Y, PX05SVB192Y, PX05SVB096Y, PX05SVB048Y, PX05SRB384Y, PX05SRB192Y, PX05SRB096Y and PX05SRB048Y.",
      "version": "AS10",
      "release_id": "1DJXX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-16T06:54:21Z",
      "released": "2019-09-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05601933M/2/SAS-Drive_Firmware_1DJXX_WN64_AS10_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1DJXX",
      "size": 12379416,
      "reboot_required": false,
      "description": "This release contains firmware version AS10 for Toshiba drives. Vendor model numbers PX05SMB320Y, PX05SMB160Y, PX05SMB080Y, PX05SMB040Y, PX05SVB384Y, PX05SVB192Y, PX05SVB096Y, PX05SVB048Y, PX05SRB384Y, PX05SRB192Y, PX05SRB096Y and PX05SRB048Y.",
      "revision_history": "Fixes:\n - Modify the Wear Leveling algorithm so that the F/W searches deeper into free super block pool. The depth for search depends on the drive capacity.\n- Modify the GC algorithm so that the F/W selects the source of GC based on the smallest valid data occupancy rate, instead of the smallest amount of valid data.\n-Modify the firmware to manage the number of internal Reads to Flash Memories as such to not hit the queue depth threshold in this heavy 4KB unaligned Rd/Wr condition.\nEnhancements:\n-N/A"
    },
    {
      "id": "1d3ab601a01a026336833ba6afbb6754ee8512d3be051f4ee76a31a19e410944",
      "name": "Windows drivers for Marvell FastLinQ 57800 series Ethernet Adapters",
      "version": "36.20.02",
      "release_id": "VYWY1",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2024-01-11T20:49:37Z",
      "released": "2024-01-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11119076M/1/Network_Driver_VYWY1_WN64_36.20.02_A00-00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VYWY1",
      "size": 38577024,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Update Package with Windows drivers for Marvell FastLinQ 57800 series Ethernet Adapters.\n\nQLogic 57810S Dual 10GE PCIe Standup SFP+/DA CNA\nQLogic 57810S Dual 10GE PCIe Standup Base-T CNA\nQLogic 57800S Quad Port  2, 1GB x 2, 10Gb rNDC Base-T\nQLogic 57800S Quad Port 2, 1GB x 2, 10Gb rNDC SFP+/DA\nQLogic 57810S-K Dual Port 10Gb bNDC KR CNA\nQLogic 57810S-k Dual Port 10Gb bMezz KR CNA\nQLogic 57840S-K Quad Port 10Gb bNDC KR CNA\nQLogic 57840S Quad Port 10GB rNDC SFP+/DA"
    },
    {
      "id": "5d8c2335761f5dc729d22a939ccc164e23f6c99632d2615b1482961702fec308",
      "name": "HGST KU45  for model number(s) HUS726020ALS210 and HUS726040ALS210.",
      "version": "KU45",
      "release_id": "68X4C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T17:03:19Z",
      "released": "2021-04-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07150772M/2/SAS-Drive_Firmware_68X4C_WN64_KU45_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=68X4C",
      "size": 11746544,
      "reboot_required": false,
      "description": "This release contains firmware version KU45  for HGST drives. Vendor model numbers HUS726020ALS210 and HUS726040ALS210.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "bb82cbf99973004ad4fa46b9d064ac1b23ea7e421990eef9b1994703259e53e1",
      "name": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095",
      "version": "CPE9",
      "release_id": "RRWVT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-11T16:56:16Z",
      "released": "2023-09-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10235085M/2/SAS-Drive_Firmware_RRWVT_WN64_CPE9_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RRWVT",
      "size": 12063856,
      "reboot_required": false,
      "description": "This release contains firmware version CPE9 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095,XS7680SE70145, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n- Fix drive detection issue.\n\nEnhancements:\n- Enable new DPN for 7.68TB capacity."
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "054ada563db4b0144ea96e61f9dfae2b5933353594c0eb1b1524e47e39567718",
      "name": "Dell Firmware Update Package for Marvell FastLinQ 57800 series Ethernet adapters",
      "version": "16.20.00",
      "release_id": "9KYR0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-01-04T19:33:19Z",
      "released": "2024-01-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11086271M/1/Network_Firmware_9KYR0_WN64_16.20.00_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=9KYR0",
      "size": 8482920,
      "reboot_required": true,
      "description": "This software bundle includes a Dell Firmware Update Package for the following Marvell FastLinQ 57800 series Ethernet adapters\n\nQLogic 57810S Dual 10GE PCIe Standup SFP+/DA CNA\nQLogic 57810S Dual 10GE PCIe Standup Base-T CNA\nQLogic 57800S Quad Port  2, 1GB x 2, 10Gb rNDC Base-T\nQLogic 57800S Quad Port 2, 1GB x 2, 10Gb rNDC SFP+/DA\nQLogic 57810S-K Dual Port 10Gb bNDC KR CNA\nQLogic 57810S-k Dual Port 10Gb bMezz KR CNA\nQLogic 57840S-K Quad Port 10Gb bNDC KR CNA\nQLogic 57840S Quad Port 10GB rNDC SFP+/DA"
    },
    {
      "id": "1422bba58673005e0d8a1f7d9ee1c898c81706f760e54c181b8a463dce6c5e22",
      "name": "Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "version": "BJ07",
      "release_id": "5WMK8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:21:19Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933394M/1/SAS-Drive_Firmware_5WMK8_WN64_BJ07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5WMK8",
      "size": 12038824,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BJ07 for RM6 SAS SSD SED program for model number(s) KRM6VVUG3T84, KRM6VVUG1T92, KRM6VVUG960G, KRM6VRUG7T68, KRM6VRUG3T84, KRM6VRUG1T92 and KRM6VRUG960G.",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "1fcbe2f15884130068fe5c7cc25584671e6f7044a740a7c5c0d2a66c178bbb28",
      "name": "Kioxia BH07 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "version": "BH07",
      "release_id": "38PHF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-12-04T11:00:20Z",
      "released": "2023-11-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10933350M/1/SAS-Drive_Firmware_38PHF_WN64_BH07_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=38PHF",
      "size": 11958960,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia BH07 for RM6 SAS SSD ISE program for model number(s) KRM6XVUG3T84, KRM6XVUG1T92, KRM6XVUG960G, KRM6XRUG7T68, KRM6XRUG3T84, KRM6XRUG1T92, KRM6XRUG960G",
      "revision_history": "Fixes: \n\nWear Leveling Issue: When the host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\n\nCause: This issue was introduced by applying the Wear-Leveling-related change in the previous firmware. The data buffer is used for data transfer during Wear-Leveling. Firmware may detect an overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where Wear-Leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\n\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "d8437b996ac697e05d66eea0c991e755d0142e2a4dbf3d2ad3bd95a4feb929d3",
      "name": "Intel NIC Family Version 22.0.0 Drivers for Windows Server 2019 and 2022 Operating Systems",
      "version": "22.0.0",
      "release_id": "X9PPT",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-11-13T18:44:32Z",
      "released": "2023-03-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09683951M/2/Network_Driver_X9PPT_WN64_22.0.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X9PPT",
      "size": 44210816,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "Fixes\n=====\n- Resolved an issue where ETrackID, NVM Version, and FW Version field information was missing\n  in ProSet for X710, XL710, and XXV710 adapters. {242553}\n- Resolved an issue where on Windows Server OSs with Intel(R) Ethernet 25G 2P E810-XXV-k Mezz\n  adapters, hardware diagnostic tests using PROSet ACU would cause errors. {240055}\n\nEnhancements\n=====\n- Introduces performance counters manifest file for Intel (R) E810 devices, which can be imported into the \n  Microsoft Windows utility PerfMon. {D3752}"
    },
    {
      "id": "214e40efd5e46246ff0fba1a8eaaf131aabdf1894e99978d7ba43c1d2a153208",
      "name": "Intel NIC Family Version 22.5.0 Drivers for Windows 64-bit Operating Systems",
      "version": "22.5.0",
      "release_id": "8FFGM",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2023-09-22T22:03:26Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646257M/1/Network_Driver_8FFGM_WN64_22.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8FFGM",
      "size": 44670672,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt."
    },
    {
      "id": "f00b0fb442568fef33a6e6b6f803cb2d327c1864b57c2f40c77208c11a0cff75",
      "name": "Intel NIC Family Version 22.5.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "22.5.7",
      "release_id": "1R0W0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T21:01:32Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646142M/1/Network_Firmware_1R0W0_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1R0W0",
      "size": 36581360,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.0.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "fe3df57f88a24821dcfe6da938dea1cb5969fd93d89df900376eb41cf1b3ac98",
      "name": "Intel NIC Family Version 22.5.0 Firmware for I350, I354, and X550 Adapters",
      "version": "22.5.7",
      "release_id": "TNXW1",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-09-22T20:37:20Z",
      "released": "2023-09-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10646092M/2/Network_Firmware_TNXW1_WN64_22.5.7_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TNXW1",
      "size": 16735312,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell Technologies Update Package to install Intel NIC Firmware Family Version 22.5.X on Intel I350, I354, and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "464b59fe39812588c5713e0530dbe62d1c68c051dda5e2cf1656c70d85840571",
      "name": "Micron 5300 SED J808 firmware for model number MTFDDAK7T6TDS",
      "version": "J808",
      "release_id": "7X7KX",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2023-08-04T09:11:19Z",
      "released": "2023-08-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10433234M/1/Serial-ATA_Firmware_7X7KX_WN64_J808_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7X7KX",
      "size": 11866584,
      "reboot_required": false,
      "description": "This  release contains  firmware for Micron 5300 SED drives (7.68TB capacity).  Firmware version J808 for Micron 5300 SED drives, model MTFDDAK7T6TDS..",
      "revision_history": "Fixes:\n-Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "76674cab6905ca47390a6c1e7bf9e87dd29131446ae0c25e99d2c4ebaaa5688a",
      "name": "Micron J808 Firmware for model number  MTFDDAK7T6TDS .",
      "version": "J808",
      "release_id": "5FYJD",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2023-06-30T09:11:18Z",
      "released": "2023-06-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10269954M/1/Serial-ATA_Firmware_5FYJD_WN64_J808_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5FYJD",
      "size": 11866552,
      "reboot_required": false,
      "description": "This release contains firmware version J808 for Micron drives. Vendor model number MTFDDAK7T6TDS.",
      "revision_history": "Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "9def27dec47cc2397036ee572890022b15e5dc0fc6e054dcfb6ffedc29b1ef59",
      "name": "Micron J008 for MTFDDAV240TDU, MTFDDAV240TDS, MTFDDAV480TDS, MTFDDAV960TDS, MTFDDAV1T9TDS,  MTFDDAK240TDS, MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS,MTFDDAK240TDT, MTFDDAK480TDT, MTFDDAK960TDT, MTFDDAK1T9TDT",
      "version": "J008",
      "release_id": "KT63Y",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2023-06-30T09:07:13Z",
      "released": "2023-06-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10269881M/1/Serial-ATA_Firmware_KT63Y_WN64_J008_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KT63Y",
      "size": 12137648,
      "reboot_required": false,
      "description": "Micron J008 for MTFDDAV240TDU, MTFDDAV240TDS, MTFDDAV480TDS, MTFDDAV960TDS, MTFDDAV1T9TDS,  MTFDDAK240TDS, MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS,MTFDDAK240TDT, MTFDDAK480TDT, MTFDDAK960TDT, MTFDDAK1T9TDT",
      "revision_history": "Fixes for FW assert issue and power loss handeling issue."
    },
    {
      "id": "7f3c1816a8abb0d5de05c5772def174d0e1ae5f6c9c2ad5523fd664903346ed8",
      "name": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "version": "CSJA",
      "release_id": "J12RT",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2023-06-30T05:01:47Z",
      "released": "2023-06-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10268173M/1/SAS-Drive_Firmware_J12RT_WN64_CSJA_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J12RT",
      "size": 12687840,
      "reboot_required": false,
      "description": "This release contains firmware version CSJA for STX drives. Vendor model numbers ST4000NM017A, ST2000NM013A, ST1000NM005A.",
      "revision_history": "Fixes:\nMake one step download work from the initial release code.\nFixes and enhancements included are identical to those of CSJ8."
    },
    {
      "id": "477ae0e56ed29128c0a723d01f5edf8737a96d8c6f711640707686489acfe7e4",
      "name": "Dell 14G /15G Internal Dual SD Module",
      "version": "2.0",
      "release_id": "X4K6X",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2023-03-02T17:15:36Z",
      "released": "2022-01-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08106962M/2/Firmware_X4K6X_WN64_2.0_A06_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=X4K6X",
      "size": 6142176,
      "reboot_required": true,
      "description": "Internal Dual SD Module Firmware Update"
    },
    {
      "id": "d6784baaf602be53256144a13d13ccebfe0dd5110a4cb33a3573fb5e5f7f467f",
      "name": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "version": "CPE6",
      "release_id": "2PY92",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-12-14T07:32:22Z",
      "released": "2022-12-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09346116M/1/SAS-Drive_Firmware_2PY92_WN64_CPE6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2PY92",
      "size": 12209992,
      "reboot_required": false,
      "description": "This release contains firmware version CPE6 for Seagate Cooper model numbers XS960SE70095, XS1920SE70095, XS3840SE70095, XS7680SE70095, XS960LE70095, XS1920LE70095, XS3840LE70095.",
      "revision_history": "Fixes:\n-Initial Release"
    },
    {
      "id": "ab0f44c74dcb6ff0616ca9a450564703d7a071909b7a90b78b0573e304ec6aa0",
      "name": "Dell 64 Bit uEFI Diagnostics, version 4301",
      "version": "4301A73",
      "release_id": "R30YT",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Optional",
      "type": "APAC",
      "posted": "2022-11-23T20:53:11Z",
      "released": "2022-06-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08404339M/2/Diagnostics_Application_R30YT_WN64_4301A73_4301.74_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R30YT",
      "size": 9505376,
      "reboot_required": false,
      "description": "Dell Diagnostics are designed to verify proper operation of the hardware in your system outside of a high level operating system environment. The files in this group can be used to update these diagnostics on a system with a Lifecycle Controller.",
      "revision_history": "Fixes: Not Applicable. Enhancements: Support new hardware."
    },
    {
      "id": "f4a150703d9d04b786eb6c25b0d0e1f20cf5ddef7c25d7e8e286718875c5648b",
      "name": "Intel NIC Family Version 21.5.0 Drivers for Windows Server 2019 and 2022 Operating Systems",
      "version": "21.5.0",
      "release_id": "7N9PV",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2022-09-08T18:05:36Z",
      "released": "2022-08-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08966610M/2/Network_Driver_7N9PV_WN64_21.5.0_A01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7N9PV",
      "size": 44578616,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt.",
      "revision_history": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019 and Windows Server 2022. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update.  For the full list of supported adapters by this release of software, please see \"Software Compatibility\" section in release.txt."
    },
    {
      "id": "6b01a365cd3ec211f0220c2550d15f29848832f62579e2e64a7467874c94f2fa",
      "name": "Seagate 4D0C for model number(s) XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "version": "4D0C",
      "release_id": "NX13G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2022-04-28T10:32:00Z",
      "released": "2022-04-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08486562M/1/SAS-Drive_Firmware_NX13G_WN64_4D0C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NX13G",
      "size": 11833104,
      "reboot_required": false,
      "description": "This release contains firmware version 4D0C for Seagate drives. Vendor model numbers XS7680SE70154, XS3840SE70154, XS1920SE70154, XS960SE70154, XS3840LE70154, XS1920LE70154, XS960LE70154",
      "revision_history": "Fixes:\nFix an issue that can cause drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can return corrupt data after a power cycle in a corner case.\nFix an issue that can return the sense code 09/80/00 to a WRITE command.\nFix issues that can cause command timeout.\nFix issues that can cause drive assert.\nFix issues that can cause drive hang condition.\nFix an issue that can cause drive-not-ready.\nEnhancements:\nImprove protocol spec compliance.\nImprove throughput performance for specific workloads.\nImprove error logging/sense data reporting."
    },
    {
      "id": "e4c618754eb7591a6a4e57d3c39ecca8351d1794ba7b4ab8de43d6466ac16649",
      "name": "Broadcom NetXtreme network device firmware, 22.0",
      "version": "22.00.6",
      "release_id": "DFF48",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2022-01-07T05:56:55Z",
      "released": "2022-01-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08077841M/1/Network_Firmware_DFF48_WN64_22.00.6.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=DFF48",
      "size": 6835704,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for Broadcom NetXtreme devices.   This release should be used with the Broadcom 21.8.2 device drivers.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for new LOM devices.."
    },
    {
      "id": "fdc517b1cf7d7b4cc1192e2107643526422aace63846cd0cc482e788678c7b9e",
      "name": "Marvell FastLinQ 57800 Series Ethernet Driver",
      "version": "35.35.03",
      "release_id": "KVF4M",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2022-01-06T04:32:27Z",
      "released": "2021-12-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08072627M/1/Network_Driver_KVF4M_WN64_35.35.03_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KVF4M",
      "size": 37762992,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Update Package with Windows drivers for Marvell FastLinQ 57800 series Ethernet Adapters.\n\nQLogic 57810S Dual 10GE PCIe Standup SFP+/DA CNA\nQLogic 57810S Dual 10GE PCIe Standup Base-T CNA\nQLogic 57800S Quad Port  2, 1GB x 2, 10Gb rNDC Base-T\nQLogic 57800S Quad Port 2, 1GB x 2, 10Gb rNDC SFP+/DA\nQLogic 57810S-K Dual Port 10Gb bNDC KR CNA\nQLogic 57810S-k Dual Port 10Gb bMezz KR CNA\nQLogic 57840S-K Quad Port 10Gb bNDC KR CNA\nQLogic 57840S Quad Port 10GB rNDC SFP+/DA",
      "revision_history": "Image Watch Classification:Class E: No Image Impact Change-Very Low: New hardware or software that does not require new software, BIOS, or system reboot."
    },
    {
      "id": "bb74a5246ad87295b5b19ae56a2f01b54a7080c518fe0e6e8a49e4012b700a8b",
      "name": "Emulex Fibre Channel Adapter Drivers and Software Application for Windows.",
      "version": "10.02.09",
      "release_id": "KM3H4",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2021-11-18T06:34:37Z",
      "released": "2021-11-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07982625M/1/Fibre-Channel_Driver_KM3H4_WN64_10.02.09_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KM3H4",
      "size": 122228696,
      "reboot_required": true,
      "description": "Emulex Fibre Channel Adapter software.",
      "revision_history": "Fixes:\n- Vulnerability: EHM GetDumpFile command can be spoofed such that it will retrieve any file on the system running the RMServer\n- Vulnerability: A spoofed GetDumpFile command specifying a filename greater than 230 characters in length causes an RMServer stack overflow/crash\n- Vulnerability: RM server allows CT command related to download command to copy irrelevant file to host\n- Vulnerability: RMServer allows creating a file with leaked memory bytes in the filename.\n- Unable to download a remote dump file to local system if the dump file name contains two non adjacent period (\".\") characters\n- EHM got aborted core dumped, when copying a file to remote server using poc_write.py vulnerability sample script\n\nEnhancements:\n- None"
    },
    {
      "id": "0d641577c496dd28e779754196b55a19c1f613a33f3548ee9658a2eb909b215a",
      "name": "Broadcom Windows 64bit driver update for NetXtreme Ethernet adapters, 21.8.2",
      "version": "21.90.2",
      "release_id": "KVNHP",
      "category": "Network",
      "category_slug": "network",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2021-09-16T23:45:53Z",
      "released": "2021-09-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07742211M/1/Network_Driver_KVNHP_WN64_21.90.2_218.0.300.0.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KVNHP",
      "size": 36641816,
      "reboot_required": false,
      "description": "Windows x64 driver update for Broadcom NetXtreme Ethernet adapters.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for Windows Server 2022"
    },
    {
      "id": "afad81c11ff922969d371d0fc4f99acfa5bc2d5a7b4cd74e2d2c1481ff5f57eb",
      "name": "Seagate KT5C for model number(s) DL900MP0136.",
      "version": "KT5C",
      "release_id": "83FF4",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-08-27T08:44:48Z",
      "released": "2021-08-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07688573M/1/SAS-Drive_Firmware_83FF4_WN64_KT5C_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=83FF4",
      "size": 11012312,
      "reboot_required": false,
      "description": "This release contains firmware version KT5C for Seagate drives. Vendor model numbers DL900MP0136.",
      "revision_history": "Fixes:\nFix an issue where single SAS port becomes unresponsive\nFix issues that can cause unwarranted SMART warning\nFix issues where assert can result\nFix issues where drive hang condition can result\nFix issues where command timeout can result\nEnhancements:\nImprove performance for certain workloads\nEnhance error logging / sense code reporting accuracy"
    },
    {
      "id": "edef243d8108958192caa385e61442f4dfeee160057a70aae31d7de1ea520510",
      "name": "Seagate KT7B for model number(s) ST900MP0136..",
      "version": "KT7B",
      "release_id": "0V8XY",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-08-27T08:28:32Z",
      "released": "2021-08-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07688491M/1/SAS-Drive_Firmware_0V8XY_WN64_KT7B_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0V8XY",
      "size": 11012712,
      "reboot_required": false,
      "description": "This release contains firmware version KT7B for Seagate drives. Vendor model numbers ST900MP0136..",
      "revision_history": "Fixes:\nFix an issue where single SAS port becomes unresponsive\nFix issues that can cause unwarranted SMART warning\nFix issues where assert can result\nFix issues where drive hang condition can result\nFix issues where command timeout can result\nEnhancements:\nImprove performance for certain workloads\nEnhance error logging / sense code reporting accuracy"
    },
    {
      "id": "80318ba926a22165790009e8aa0a953888eeddac60c085b60146da569d6c5aa9",
      "name": "Intel NIC Family Version 20.5.0 Ethernet Driver",
      "version": "20.5.0",
      "release_id": "2YNFG",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2021-07-08T17:20:16Z",
      "released": "2021-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07537990M/1/Network_Driver_2YNFG_WN64_20.5.0_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2YNFG",
      "size": 43279168,
      "reboot_required": false,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2019. This release provides continued code optimization to improve performance. This program is protected by copyright law and international treaties. Please extract contents to view the software license agreement before installing the software update. Please extract the release note \"release.txt\" to find the supported adapters by this software bundle.",
      "revision_history": "Fixes and Enhancements are located in the associated \"release.txt\" file."
    },
    {
      "id": "0b3344f7804b9914f344d27c213c21a5319fd44e230cd2ec2bf6315e7f6b6974",
      "name": "Intel Chipset Driver",
      "version": "10.1.18807.8279",
      "release_id": "MPXXJ",
      "category": "Chipset",
      "category_slug": "chipset",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2021-06-30T14:30:32Z",
      "released": "2021-06-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07511026M/2/Chipset_Driver_MPXXJ_WN64_10.1.18807.8279_A06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MPXXJ",
      "size": 7706104,
      "reboot_required": true,
      "description": "This package provides the Chipset driver for the Intel Lewisburg C62x Series Chipset and is supported on 14G PowerEdge systems running Windows Server 2012 R2 x64 , Windows Server 2016 x64, Windows Server 2019, and Windows Server 2022.",
      "revision_history": "Fixes:\n-NA\n\nEnhancements:\n-Adds support for Windows Server 2022"
    },
    {
      "id": "adce5518819d994395a3da8c14eac4445c135530da8b81773881f54065a6b379",
      "name": "Mellanox ConnectX-3 and ConnectX-3 Pro Ethernet adapter Firmware.",
      "version": "02.42.50.58",
      "release_id": "H9RJP",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2021-05-05T18:40:49Z",
      "released": "2021-04-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07319590M/1/Network_Firmware_H9RJP_WN64_02.42.50.58.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H9RJP",
      "size": 22600384,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-3 and ConnectX-3 Pro Ethernet Adapters:\n- Mellanox ConnectX-3 Dual Port 40 GbE QSFP+ Ethernet Adapter\n- Mellanox ConnectX-3 Dual Port 10 GbE DA/SFP+ Ethernet Adapter\n- Mellanox ConnectX-3 Dual Port 10 GbE KR Blade Mezzanine Ethernet Card\n- Mellanox ConnectX-3 Pro Dual Port 40 GbE QSFP+ Ethernet Adapter\n- Mellanox ConnectX-3 Pro Dual Port 10 GbE DA/SFP+ Ethernet Adapter\n- Mellanox ConnectX-3 Pro Dual Port 10 GbE KR Blade Mezzanine Ethernet Card"
    },
    {
      "id": "9f54d16b6a912067843cc2bd8568d7b9c3911cac62f7725298299613a5828fca",
      "name": "Seagate Lange Firmware Version EC16  for model number(s) XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "version": "EC16",
      "release_id": "H3VHX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2021-02-04T09:29:43Z",
      "released": "2021-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07035193M/1/SAS-Drive_Firmware_H3VHX_WN64_EC16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3VHX",
      "size": 10683112,
      "reboot_required": false,
      "description": "This release contains firmware version EC16 for Seagate drives. Vendor model numbers XS960SE70074, XS1920SE70074, XS3840SE70074, XS7680SE70074.",
      "revision_history": "Fixes:\n-Fix an issue where reading or writing of corrupt data can result after a power cycle\n-Fix an issue which can lead to reduced data retention duration\n-Fix an issue where assert can result when max. queue depth is exceeded\n-Update activity LED blinking behavior to be consistent with Dell requirements\n\nEnhancements:\n-N/A"
    },
    {
      "id": "fb3ce025fe874b8b897335b634e46dfbd185631a96cf2a1397ec833c58f2ae0e",
      "name": "Samsung PM1645 MU ISE 2.5 SSDR, FW DWF8 for model number(s) MZILT800HAHQ0D3, MZILT1T6HAJQ0D3 and MZILT3T2HALS0D3",
      "version": "DWF8",
      "release_id": "C9JP2",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-12-18T10:58:27Z",
      "released": "2020-12-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06895828M/1/SAS-Drive_Firmware_C9JP2_WN64_DWF8_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=C9JP2",
      "size": 10636000,
      "reboot_required": false,
      "description": "This release contains firmware version DWF8 for SAMSUNG model number(s) MZILT800HAHQ0D3, MZILT1T6HAJQ0D3 and MZILT3T2HALS0D3",
      "revision_history": "Fixes:\n- Addition of High Capacity drives to common FW version.\n- Addressed Read Timeout errors found during high queue depth / small transfer length.\n- Multiple other minor bug fixes.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "048766de7693698178a808fce6d3c552a844ef53f883ca214c7b4aa694bacf92",
      "name": "OS COLLECTOR, v6.0",
      "version": "6.0",
      "release_id": "0G1JH",
      "category": "Diagnostics",
      "category_slug": "diagnostics",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2020-12-15T14:24:17Z",
      "released": "2020-12-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06878175M/2/Diagnostics_Application_0G1JH_WN64_6.0_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0G1JH",
      "size": 40064016,
      "reboot_required": false,
      "description": "OS COLLECTOR  6.0 is an integral component of the PowerEdge Embedded SupportAssist solution. OS COLLECTOR 6.0 is designed to supplement the iDRAC hardware state and configuration data with the host's operating system state \u0026 configuration information data as well as the system event logs. The purpose of Embedded SupportAssist is to enable serviceability on the box without the need to install or configure additional software on the customers' host. Embedded SupportAssist is available on the box, the day of RTS without enablement from the serviceability tools.",
      "revision_history": "Fixes:NA\nEnhancements:NA"
    },
    {
      "id": "0ffe3c000f86d9cb0ce092879226f16abee7f1d5a18e94f55f6f809a820b9358",
      "name": "Windows drivers for Marvell FastLinQ Ethernet and Marvell QLogic Fibre Channel adapters",
      "version": "35.17.03",
      "release_id": "3H0TY",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2020-12-07T20:47:27Z",
      "released": "2020-11-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06858546M/1/Network_Driver_3H0TY_WN64_35.17.03_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3H0TY",
      "size": 53692536,
      "reboot_required": false,
      "description": "This software bundle includes the Dell Update Package with Windows Drivers for following Marvell adapters.\n\nMarvell QLogic Fibre Channel Adapters\n\nQLE2560 FC8 Single Channel HBA\nQLE2562 FC8 Dual Channel HBA\nFC8 Embedded Mezz Card QME2572\nQME2662 Dual Port FC16 HBA Mezzanine\nQLE2662 Dual Port FC16 HBA\nQLE2660 Single Port FC16 HBA\nQLE2690 Single Port 16Gb FC to PCIe Gen3 x8 Adapter\nQLE2692 Dual Port 16Gb FC to PCIe Gen3 x8 Adapter\nQLE2740 Single Port 32Gb FC to PCIe Gen3 x8 Adapter\nQLE2742 Dual Port 32Gb FC to PCIe Gen3 x8 Adapter\nQLogic 2x16Gb QME2692 FC HBA\nQLogic 2x32Gb QME2742 FC HBA\nQLogic 1x32Gb QLE2770 FC HBA\nQLogic 2x32Gb QLE2772 FC HBA\n\nMarvell FastLinQ Ethernet Adapters\n\nQL41162-DE 10 Gigabit Ethernet\nQL41112-DE 10 Gigabit Ethernet\nQL41262-DE 25 Gigabit Ethernet\nQLogic 4x10GE QL41164HMRJ CNA \nQLogic 4x10GE QL41164HMCU CNA\nQLogic 2x25GE QL41262HMCU CNA\nQLogic 2x1GE+2x10GE QL41264HMCU CNA\nQLogic 2x1GE+2x10GE QL41162HMRJ CNA\nQLogic 4x10GE QL41164HxRJ CNA\nQLogic 4x10GE QL41164HFCU CNA\nQLogic 2x25GE QL41262HMKR CNA\nQLogic 2x25GE QL41232HMKR NIC\nQLogic 2x10GE QL41132HxRJ NIC\nQLogic 2x25GE QL41232HxCU NIC\nQLogic 2x25GE QL41232HQCU NIC\nQLogic_2x10GT QL41132HQRJ NIC\nQLogic 2x10GE QL41132HQCU NIC",
      "revision_history": "Fixes\n=====\n- Fixed an issue where the installation of the drivers causes a system crash (BSOD) on a Window 2019 VM having SR-IOV virtual functions assigned on ESXi Hypervisor\n\nEnhancements\n======\n- Added support for Azure Stack HCI v1 OS"
    },
    {
      "id": "f1cd1236f7aeee62f432fb99d9dba287c1d0b7175d9ac9300b906fb35d3376bf",
      "name": "Dell Firmware Update Package for Marvell QLogic 25xx series Fibre Channel adapters",
      "version": "09.01.07",
      "release_id": "J5Y1Y",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-07-24T03:40:11Z",
      "released": "2020-07-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06433702M/1/Fibre-Channel_Firmware_J5Y1Y_WN64_09.01.07_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J5Y1Y",
      "size": 11410864,
      "reboot_required": true,
      "description": "This software bundle includes a Dell Firmware Update Package for the following Marvell QLogic  2500 series Fibre Channel adapters.\n\nQLE2560 FC8 Single Channel HBA\nQLE2562 FC8 Dual Channel HBA\nFC8 Embedded Mezz Card QME2572",
      "revision_history": "Fixes:\n-------\nFor a complete list of all the fixes in this release, please download EndUserReleaseNotes.pdf file under QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters.This can be found under Network category of the Dell Drivers and Download Support web page.\n\nEnhancements:\n------------------\nFor a complete list of Enhancements in this release, please download EndUserReleaseNotes.pdf file under QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page"
    },
    {
      "id": "512db1c2b29fcc3c3a0bcf5fad4b759d3e86ea2a13fb5b1b8827f80e9f6da949",
      "name": "Dell Firmware Update Package for Marvell QLogic 266x and 269x series Fibre Channel adapters",
      "version": "15.15.06",
      "release_id": "M5JNP",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-07-24T03:37:24Z",
      "released": "2020-07-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06433693M/1/Fibre-Channel_Firmware_M5JNP_WN64_15.15.06_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M5JNP",
      "size": 12342808,
      "reboot_required": true,
      "description": "This software bundle includes a Dell Firmware Update Package for the following Marvell QLogic 2660 and 2690 series Fibre Channel adapters.\n\nQME2662 Dual Port FC16 HBA Mezzanine\nQLE2662 Dual Port FC16 HBA\nQLE2660 Single Port FC16 HBA\nQLE2690 Single Port 16Gb FC to PCIe Gen3 x8 Adapter\nQLE2692 Dual Port 16Gb FC to PCIe Gen3 x8 Adapter\nQLogic 2x16Gb QME2692 FC HBA",
      "revision_history": "Fixes:\n-------\nFor a complete list of all the fixes in this release, please download EndUserReleaseNotes.pdf file under - QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page.\n\n\nEnhancements:\n------------------\nFor a complete list of Enhancements in this release, please download EndUserReleaseNotes.pdf file under - QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page."
    },
    {
      "id": "9041cde085d57e0a1994cac3b5c1509ca4847190cba4f1be417e47a91813d517",
      "name": "Mellanox Windows 64-bit Server Operating System drivers for Mellanox ConnectX-3 and ConnectX-3 Pro Ethernet adapters",
      "version": "05.050.09",
      "release_id": "VMPP8",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2020-07-22T15:42:11Z",
      "released": "2020-03-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06146115M/3/Network_Driver_VMPP8_WN64_05.050.09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VMPP8",
      "size": 199802640,
      "reboot_required": false,
      "description": "This package provides the Windows 64-bit drivers for Mellanox ConnectX-3 and ConnectX-3 Pro Ethernet Adapters and is supported on Dell EMC PowerEdge servers with the following operating systems: Windows Server 2016 and Window Server 2019",
      "revision_history": "Fixes: \n- Fixed an issue that resulted in a BSOD when changed the number of queues/CQ in VMMQ.\n- Fixed an issue that resulted in system crash while updating the VPort in the error flow.\n- Fixed a race condition that occurred when sending RDMA-send-messages between the storage nodes and the compute nodes which resulted in RDMA connectivity loss.\n- Fixed an issue that prevented the NIC from enabling NVGRE or VXLAN although they were enabled by the user.\n\nEnhancements:  None"
    },
    {
      "id": "b5609c67149d58ecc6e49b3642795f0d0682e095f3073cf624591b6e2cf7a799",
      "name": "Emulex Fibre Channel Adapter Drivers and Software Application for Windows.",
      "version": "10.2.8",
      "release_id": "V17DD",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2020-07-01T22:35:35Z",
      "released": "2020-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06352593M/1/Fibre-Channel_Driver_V17DD_WN64_10.2.8_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=V17DD",
      "size": 122143680,
      "reboot_required": true,
      "description": "Emulex Fibre Channel Adapter software."
    },
    {
      "id": "2f1c28fa8244346db9bb665f88329e3927ce88733053b536665c9275d41d5d39",
      "name": "Emulex Fibre Channel Adapter Firmware.",
      "version": "03.03.37",
      "release_id": "T8P92",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-07-01T22:35:27Z",
      "released": "2020-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06352596M/1/Fibre-Channel_Firmware_T8P92_WN64_03.03.37_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T8P92",
      "size": 8210864,
      "reboot_required": false,
      "description": "Dell Update Package for updating firmware on the Emulex Fibre Channel adapters",
      "revision_history": "Fixes:\n - (12000 series) Slow POST in specific servers/slots in legacy BIOS boot mode.\n - Scan for devices in BFS not working with Unity XT Array.\n - (35000 series) Intermittent failures when running internal loopback test.\n\nEnhancements:\n - Add support for SLES15 SP2\n - Add support for RHEL8.2"
    },
    {
      "id": "629d5fb27f74f6eb49ee0f4138a473929570edcca75b5a873ae5090655987a4a",
      "name": "Toshiba EA05 for model number(s) AL14SEB030NY, AL14SEB060NY and AL14SEB120NY.",
      "version": "EA05",
      "release_id": "TGCJ8",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-03-27T11:21:24Z",
      "released": "2020-03-27T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06178570M/1/SAS-Drive_Firmware_TGCJ8_WN64_EA05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TGCJ8",
      "size": 10476472,
      "reboot_required": false,
      "description": "This release contains firmware version EA05 for Toshiba drives. Vendor model numbers AL14SEB030NY, AL14SEB060NY and AL14SEB120NY.",
      "revision_history": "Fixes:\n- Invalid DWORD during Link Reset\n- Apply the Pin11 Specification rev A03\n- 04-4C-91 when drive executes internal reboot\n- Self reboot when 8 commands terminated for TASK SET FULL\n- HDD reports sense 02-04-11 on NOTIFY (Enable Spin Up)\n- Write splice may occur on power loss during ATI\n- HDD hang under specific conditions when Task Set Full\n- HDD hang under specific conditions when TB=1\n- Soft errors in SoC memory\n- Power loss during self test \n- Duplicate sense code sent\n- HDD may hang on hard reset\n\nEnhancements:\n N/A"
    },
    {
      "id": "9cb177ff68cdcacaea5c2e503623fd7a714f7fb1636ab3be4d51aa44fba3c959",
      "name": "Toshiba EB04 for model number(s) AL14SEB18EQY.",
      "version": "EB04",
      "release_id": "NYK8R",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2020-02-05T05:29:40Z",
      "released": "2020-02-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06078016M/1/SAS-Drive_Firmware_NYK8R_WN64_EB04_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NYK8R",
      "size": 10660512,
      "reboot_required": false,
      "description": "This release contains firmware version EB04 for Toshiba drives. Vendor model numbers AL14SEB18EQY..",
      "revision_history": "DOW weight increased to improve protection against signal degradation by ATI"
    },
    {
      "id": "4e475c64044e2b4310b7bfc28bedbd8473526842287672898b7b8f28dc2d82bf",
      "name": "QLogic FastLinQ QL41xxx, FC Adapters 64 bit Windows Drivers",
      "version": "35.05.00",
      "release_id": "JWPN6",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2019-12-16T17:10:56Z",
      "released": "2019-12-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05992127M/2/Network_Driver_JWPN6_WN64_35.05.00_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=JWPN6",
      "size": 54195848,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Update Package to install QLogic  Drivers on Windows 64 bit Operating system \n\nFibre Channel Supported Products\n\nQLE2560 FC8 Single Channel HBA\nQLE2562 FC8 Dual Channel HBA\nFC8 Embedded Mezz Card QME2572\nQME2662 Dual Port FC16 HBA Mezzanine\nQLE2662 Dual Port FC16 HBA\nQLE2660 Single Port FC16 HBA\nQLE2690 Single Port 16Gb FC to PCIe Gen3 x8 Adapter\nQLE2692 Dual Port 16Gb FC to PCIe Gen3 x8 Adapter\nQLE2740 Single Port 32Gb FC to PCIe Gen3 x8 Adapter\nQLE2742 Dual Port 32Gb FC to PCIe Gen3 x8 Adapter\nQLogic 2x16Gb QME2692 FC HBA\nQLogic 2x32Gb QME2742 FC HBA\nQLogic 1x32Gb QLE2770 FC HBA\nQLogic 2x32Gb QLE2772 FC HBA\n\n\nEthernet Supported Products\n\nQL41162-DE 10 Gigabit Ethernet\nQL41112-DE 10 Gigabit Ethernet\nQL41262-DE 25 Gigabit Ethernet\nQLogic 4x10GE QL41164HMRJ CNA \nQLogic 4x10GE QL41164HMCU CNA\nQLogic 2x25GE QL41262HMCU CNA\nQLogic 2x1GE+2x10GE QL41264HMCU CNA\nQLogic 2x1GE+2x10GE QL41162HMRJ CNA\nQLogic 4x10GE QL41164HxRJ CNA\nQLogic 4x10GE QL41164HFCU CNA\nQLogic 2x25GE QL41262HMKR CNA\nQLogic 2x25GE QL41232HMKR NIC\nQLogic 2x10GE QL41132HxRJ NIC\nQLogic 2x25GE QL41232HxCU NIC\nQLogic 2x25GE QL41232HQCU NIC\nQLogic_2x10GT QL41132HQRJ NIC\nQLogic 2x10GE QL41132HQCU NIC\nQLogic 4x10GE QL41154HQRJ CNA\nQLogic 4x10GE QL41154HQCU CNA",
      "revision_history": "Fixes:\n-------\nFor a complete list of all the fixes in this release, please download EndUserReleaseNotes.pdf file under - QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page.\n\n\nEnhancements:\n------------------\nFor a complete list of Enhancements in this release, please download EndUserReleaseNotes.pdf file under - QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page."
    },
    {
      "id": "58ae83486fd525a6d7fc92aba56631b2227f7de7e3c671e4c14af15dbbc4d976",
      "name": "Intel NIC Family Version 19.5.0 Firmware for I350, I354, X520, X540, and X550 adapters",
      "version": "19.5.12",
      "release_id": "40NTK",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-12-09T20:56:33Z",
      "released": "2019-12-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05982935M/1/Network_Firmware_40NTK_WN64_19.5.12_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=40NTK",
      "size": 15755136,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Family Version 19.5.x on Intel I350, I354, X520, X540, and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "44c31e84bbef4ac6173454ad950f39f22783b042a0ef5832d420bdc0789f365f",
      "name": "Emulex Fibre Channel Adapter Firmware.",
      "version": "03.02.18",
      "release_id": "PMYJH",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-10-31T20:09:20Z",
      "released": "2019-10-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05909031M/1/Fibre-Channel_Firmware_PMYJH_WN64_03.02.18_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PMYJH",
      "size": 8173128,
      "reboot_required": true,
      "description": "Dell Update Package for updating firmware on the Emulex Fibre Channel adapters"
    },
    {
      "id": "8b261aa1080cecb64c8ca48e687208602108b4d5ae173c8fa46965296fc0a633",
      "name": "Matrox Video Driver",
      "version": "4.4.0.4",
      "release_id": "N1HM4",
      "category": "Video",
      "category_slug": "video",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2019-10-22T05:43:09Z",
      "released": "2018-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05278833M/5/Video_Driver_N1HM4_WN64_4.4.0.4_A00_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N1HM4",
      "size": 6189248,
      "reboot_required": true,
      "description": "This package contains the Matrox Video driver. A graphics or video driver is the software that enables communication between the graphics card and the operating system, games, and applications.",
      "revision_history": "Initial Release"
    },
    {
      "id": "24660d90ba56be91ab19acf032b4eeb6a09aa76efffd60ac5187381fb8faf9d1",
      "name": "Intel NIC Family Version 18.3.0 Drivers for Windows 64-bit Operating Systems",
      "version": "18.3.0",
      "release_id": "N5GYM",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2019-09-13T05:01:45Z",
      "released": "2017-10-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04588126M/6/Network_Driver_N5GYM_WN64_18.3.0_A00_04.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=N5GYM",
      "size": 84116304,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Drivers on Windows Server 2016, Windows Server 2012 R2, Windows 10 x64, Windows 8.1 x64, and Windows 7 x64.\n\nSupported Adapters:\n\nIntel(R) Ethernet 10G 2P X520 Adapter\nIntel(R) Ethernet 10G 2P X520-k bNDC\nIntel(R) Ethernet 10G 2P X540-t Adapter\nIntel(R) Ethernet 10G 2P X710-k bNDC\nIntel(R) Ethernet 10G 4P X520/I350 rNDC\nIntel(R) Ethernet 10G 4P X540/I350 rNDC\nIntel(R) Ethernet 10G 4P X710 SFP+ rNDC\nIntel(R) Ethernet 10G 4P X710/I350 rNDC\nIntel(R) Ethernet 10G X710 rNDC\nIntel(R) Ethernet 10G 4P X710-k bNDC\nIntel(R) Ethernet 10G X520 LOM \nIntel(R) Ethernet 10G X710-k bNDC\nIntel(R) Ethernet Connection I354 1.0 GbE Backplane \nIntel(R) Ethernet Converged Network Adapter X710\nIntel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezz\nIntel(R) Gigabit 2P I350 LOM\nIntel(R) Gigabit 2P I350-t Adapter\nIntel(R) Gigabit 2P I350-t LOM\nIntel(R) Gigabit I350-t LOM\nIntel(R) Gigabit 4P I350-t Adapter\nIntel(R) Gigabit 4P I350-t bNDC\nIntel(R) Gigabit 4P I350-t Mezz\nIntel(R) Gigabit 4P I350-t rNDC\nIntel(R) Gigabit 4P X520/I350 rNDC\nIntel(R) Gigabit 4P X540/I350 rNDC\nIntel(R) Gigabit 4P X710/I350 rNDC\nIntel(R) Gigabit 4P X550/I350 rNDC\nIntel(R) Ethernet 10G 2P X550-t Adapter \nIntel(R) Ethernet 10G 4P X550/I350 rNDC\nIntel(R) Ethernet 10G 4P X550 rNDC \nIntel(R) Ethernet Converged Network Adapter XL710-Q2\nIntel(R) Ethernet 40G 2P XL710 QSFP+ rNDC\nIntel(R) Ethernet Converged Network Adapter X710-T\nIntel(R) Ethernet Server Adapter X710-DA2 for OCP\n\nNote: This package does not support X710 and XL710 adapters in Windows 10, Windows 8.1, and Windows 7 with the exception of supporting the Intel(R) Ethernet 10G 4P X710/I350 rNDC on Windows 10 and Windows 7."
    },
    {
      "id": "d70e124fd5eb47e2c840087efbaab515361bdd2d7a22418a95246960b9800a43",
      "name": "Samsung DSL8 for model number(s) MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "version": "DSL8",
      "release_id": "PN27G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T20:14:23Z",
      "released": "2018-05-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04994832M/2/SAS-Drive_Firmware_PN27G_WN64_DSL8_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PN27G",
      "size": 10407664,
      "reboot_required": false,
      "description": "This release contains firmware version DSL8 for Samsung drives. Vendor model numbers MZILS480HEGR0D3, MZILS960HEHP0D3, MZILS1T9HEJH0D3 and MZILS3T8HMLH0D3.",
      "revision_history": "Fixes\n-n/a\n\nEnhancements\n-n/a"
    },
    {
      "id": "c167a624468a834e419f2e7acf82c5cc2654cbe751c39da1c3c9ecfb54e0cfaa",
      "name": "Seagate NT72 for model number(s) ST2000NX0373.",
      "version": "NT72",
      "release_id": "WN08D",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T19:37:16Z",
      "released": "2018-12-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05384185M/4/SAS-Drive_Firmware_WN08D_WN64_NT72_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WN08D",
      "size": 10530576,
      "reboot_required": false,
      "description": "This release contains firmware version NT72 for SUPPLIER model number(s) ST2000NX0373  Capacity of 2TB.",
      "revision_history": "fixes:\n-improve compatibility with Linux OS after Sanitize Cryptographic Erase was performed\n-Fix issues where Command Timeout can result\n-Fix issues where Assert can result\n-Fix an issue where drive hang can result\n-Fix an issue where Current Mode Page values revert to Default values after power cycle\n\nenhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "53b47614f9bb88da29587487d12454f8cd18c755ca02e7b02a24619b5e423efb",
      "name": "Emulex Fibre Channel Adapter Drivers and Software Application for Windows.",
      "version": "10.1.2",
      "release_id": "KXVPM",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2019-07-19T00:55:26Z",
      "released": "2019-07-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05742430M/1/Fibre-Channel_Driver_KXVPM_WN64_10.1.2_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KXVPM",
      "size": 162666552,
      "reboot_required": true,
      "description": "Emulex Fibre Channel Adapter software.",
      "revision_history": "Fixes:\n- None\n\nEnhancements:\n- Add support for new Dell platforms.\n- Add support for trunking."
    },
    {
      "id": "74e6d21311ae365ccd62cb50cd00987abbac6592d8e3c7957a6efc5949a5cc4b",
      "name": "QLogic FastLinQ QL41xxx,45xxx  Adapters 64-bit Windows Drivers",
      "version": "34.11.00",
      "release_id": "XWRKT",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2019-07-15T17:19:58Z",
      "released": "2019-07-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05734546M/1/Network_Driver_XWRKT_WN64_34.11.00_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=XWRKT",
      "size": 60130840,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Update Package to install QLogic NIC Drivers on Windows 64 bit Operating system including Windows Server 2019, Windows Server 2016, Windows Server 2012 (and R2),\n\nFibre Channel Supported Products\n\n- QLE2560 FC8 Single Channel HBA \n- QLE2562 FC8 Dual Channel HBA \n- FC8 Embedded Mezz Card QME2572 \n- QME2662 Dual Port FC16 HBA Mezzanine \n- QLE2662 Dual Port FC16 HBA \n- QLE2660 Single Port FC16 HBA \n- QLE2690 Single Port 16Gb FC to PCIe Gen3 x8 Adapter \n- QLE2692 Dual Port 16Gb FC to PCIe Gen3 x8 Adapter \n- QLE2740 Single Port 32Gb FC to PCIe Gen3 x8 Adapter \n- QLE2742 DualPort 32Gb FC to PCIe Gen3 x8 Adapter \n- QLogic 2x16Gb QME2692 FC HBA \n- QLogic 2x32Gb QME2742 FC HBA \n\nEthernet Supported Products\n\n- QL41162-DE 10 Gigabit Ethernet \n- QL41112-DE 10 Gigabit Ethernet \n- QL41262-DE 25 Gigabit Ethernet \n- QLogic 4x10GE QL41164HMRJ CNA  \n- QLogic 4x10GE QL41164HMCU CNA \n- QLogic 2x25GE QL41262HMCU CNA \n- QLogic 2x1GE+2x10GE QL41264HMCU CNA \n- QLogic 2x1GE+2x10GE QL41162HMRJ CNA \n- QLogic 4x10GE QL41164HxRJ CNA \n- QLogic 4x10GE QL41164HFCU CNA \n- QLogic 2x25GE QL41262HMKR CNA \n- QLogic 2x25GE QL41232HMKR NIC",
      "revision_history": "Fixes:\n-------\nFor a complete list of all the fixes in this release, please download EndUserReleaseNotes.pdf file under - QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page.\n\n\nEnhancements:\n------------------\nFor a complete list of Enhancements in this release, please download EndUserReleaseNotes.pdf file under - QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page."
    },
    {
      "id": "88ef2ad755dec9529576ce569e05f5a033b45bea9543d042ea19072fdac81401",
      "name": "Toshiba AX0B for model number(s) PX05SVQ192B, PX05SVQ384B and PX05SVQ096B.",
      "version": "AX0B",
      "release_id": "6CKWM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-05-05T04:34:33Z",
      "released": "2019-05-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05601856M/1/SAS-Drive_Firmware_6CKWM_WN64_AX0B_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=6CKWM",
      "size": 10865384,
      "reboot_required": false,
      "description": "This release contains firmware version AX0B for Toshiba drives. Vendor model numbers PX05SVQ192B, PX05SVQ384B and PX05SVQ096B.",
      "revision_history": "Fixes:\n- Modify the Wear Leveling algorithm so that the F/W searches deeper into free super block pool. The depth for search depends on the drive capacity.\n- Modify the GC algorithm so that the F/W selects the source of GC based on the smallest valid data occupancy rate, instead of the smallest amount of valid data.\n-Modify the firmware to manage the number of internal Reads to Flash Memories as such to not hit the queue depth threshold in this heavy 4KB unaligned Rd/Wr condition.\nEnhancements:\n-N/A"
    },
    {
      "id": "06e6fa1d3e0650bdf356b4d03849c30c13263e8e3565403075dfdeb7a65f1a3e",
      "name": "Seagate BS05 for HDD ON 2.5 SAS12 15K 512e drive model number ST600MM0238 and ST300MM0078.",
      "version": "BS05",
      "release_id": "2R4CX",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-02-15T05:59:39Z",
      "released": "2019-02-02T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05461025M/1/SAS-Drive_Firmware_2R4CX_WN64_BS05_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=2R4CX",
      "size": 10737736,
      "reboot_required": false,
      "description": "This release contains firmware version BS05 for Seagate HDD Thunderbug 2.5 SAS12 10K 512n drive. Vendor model numbers: ST600MM0238 and ST300MM0078",
      "revision_history": "Fixes:\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Current Mode Page values reverted to Default values after Power Cycle     \n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\n-Fix issues where command timeout can result\n-Fix issues where IOEDC error can result\n\nEnhancements:\n-Improve status/reporting accuracy"
    },
    {
      "id": "a34cdcfc5e6d92ca876fde3f6ae566e7cd07bbb5d8a4ec43d16cfdbafa67a8c9",
      "name": "Samsung GC5B for model number(s) MZ7LM240HMHQ0D3, MZ7LM480HMHQ0D3, MZ7LM960HMJP0D3, MZ7LM1T9HMJP0D3 and MZ7LM3T8HMLP0D3.",
      "version": "GC5B",
      "release_id": "P2YRJ",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T19:40:27Z",
      "released": "2018-03-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04918034M/2/Serial-ATA_Firmware_P2YRJ_WN64_GC5B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P2YRJ",
      "size": 10201336,
      "reboot_required": false,
      "description": "This release contains firmware version GC5B for Samsung drives. Vendor model numbers MZ7LM240HMHQ0D3, MZ7LM480HMHQ0D3, MZ7LM960HMJP0D3, MZ7LM1T9HMJP0D3 and MZ7LM3T8HMLP0D3.",
      "revision_history": "Fixes:\n-Addresses rare case where drive will return uncorrectable read errors\n\nEnhancements:\n-Improves start up time after power on\n-Improved power loss protection"
    },
    {
      "id": "ea77883e1d7020174b120a62a309c58ef8a2b204946c33f45be22cb4cf140f38",
      "name": "Samsung GB55 for model number(s) MZ7KM240HAGR00D3, MZ7KM480HAHP00D3, MZ7KM960HAHP00D3, MZ7KM1T9HAJM00D3, MZ8KM240HAGR00D3, MZ8KM480HAHP00D3 and MZ8KM960HAJH00D3.",
      "version": "GB55",
      "release_id": "P3C5P",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2019-01-30T19:24:24Z",
      "released": "2017-11-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04665610M/2/Serial-ATA_Firmware_P3C5P_WN64_GB55_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P3C5P",
      "size": 9803832,
      "reboot_required": false,
      "description": "This release contains firmware version GB55 for Samsung drives. Vendor model numbers MZ7KM240HAGR00D3, MZ7KM480HAHP00D3, MZ7KM960HAHP00D3, MZ7KM1T9HAJM00D3, MZ8KM240HAGR00D3, MZ8KM480HAHP00D3 and MZ8KM960HAJH00D3.",
      "revision_history": "Fixes:\n-Fixes rare case where drive will enter error mode after power loss\n-Numerous other bug fixes\n\nEnhancements:\n-N/A"
    },
    {
      "id": "2b640a1d6164bd5474c4daf2317c4d1e2048836e0608b4b0a3b0caa51e708a90",
      "name": "Seagate NT32 for model number(s) ST2000NX0463 and ST1000NX0473.",
      "version": "NT32",
      "release_id": "GW3V7",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T09:37:37Z",
      "released": "2018-08-15T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05151883M/2/SAS-Drive_Firmware_GW3V7_WN64_NT32_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GW3V7",
      "size": 10436112,
      "reboot_required": false,
      "description": "This release contains firmware version NT31 for Seagate drives. Vendor model numbers ST2000NX0463 and ST1000NX0473.",
      "revision_history": "Fixes\n- Enable Cache Management Resource Overflow Prevention to resolve command timout\n- Current Mode Page values reverted to Default values after Power Cycle\n- Drive fails to protect the sector if EPOW arrives during write retries\n- Command timeouts after Sanitize Command is executed\n- DEFT fails segment unexpectedly when interrupted\n- Drive Self-Test Read Scan Stuck\n- Pad LOD Files To 4K Boundary for Dell SAS\n- Unexpected power mode transition during Background Extended DST causing assert\n- Assert after Task Management Function aborted by Hard Reset\n- Various asserts reported during Active Immediate command\n- Modify Sanitize Crypto Erase behavior to write zeros to OD and ID\n- Turn on the PS bit for mode page 19 subpages\n- Assert on Sequential Write When First Write is Sending Status\n- Enable Support for Active DIC feature on DELL MC and BC configurations\n- Update DST subtest to improve handling of commands that interrupt DST.\n- Drive reported false tag overlap error 0B/4E/00/01\n- Drive did not reject Default DST command while DEFT in progress\n- Drive Assert during Band Delete/Create with concurrent I/O\n- Data abort on channel hardware access after PLL loss-of-lock\n\nEnhancements\nn/a"
    },
    {
      "id": "7810a0e644059372aafe47c89d027a7f1b7fcc39960a1c08b6b043af6a90654f",
      "name": "**FOR 2.5in DRIVE ONLY** Toshiba DACB for model number(s) THNSF8120CCSE, THNSF8240CCSE, THNSF8480CCSE, THNSF8960CCSE, THNSF81D92CSE, THNSF8200CCSE, THNSF8400CCSE, THNSF8800CCSE and THNSF81D60CSE.",
      "version": "DACB",
      "release_id": "H3XHN",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T08:54:07Z",
      "released": "2018-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04987916M/2/Serial-ATA_Firmware_H3XHN_WN64_DACB_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H3XHN",
      "size": 10358360,
      "reboot_required": false,
      "description": "This release contains firmware version DACB for 2.5in Toshiba drives. Vendor model numbers THNSF8120CCSE, THNSF8240CCSE, THNSF8480CCSE, THNSF8960CCSE, THNSF81D92CSE, THNSF8200CCSE, THNSF8400CCSE, THNSF8800CCSE and THNSF81D60CSE.",
      "revision_history": "Fixes\n-Addresses rare condition during operation were the drive stops responding to host commands and then enters a hang state that can be recovered via a power cycle.\n\nEnhancements\nn/a"
    },
    {
      "id": "e21d22a03055226af0ba080ecee384a30f94389ca4fa174eae3d7898277fcb87",
      "name": "Intel DL43 for model number(s) SSDSC2BB120G7R, SSDSC2BB150G7R, SSDSC2BB240G7R, SSDSC2BB480G7R, SSDSC2BB800G7R, SSDSC2BB960G7R, SSDSC2BB012T7R, SSDSC2BB016T7R, SSDSCKJB120G7R, SSDSCKJB150G7R, SSDSCKJB240G7R, SSDSCKJB480G7R, SSDSCKJB760G7R and SSDSCKJB960G7R.",
      "version": "DL43",
      "release_id": "CHJGV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T07:56:34Z",
      "released": "2017-10-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04614468M/2/Serial-ATA_Firmware_CHJGV_WN64_DL43_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CHJGV",
      "size": 10183056,
      "reboot_required": false,
      "description": "This release contains firmware version DL43 for Intel drives. Vendor model numbers SSDSC2BB120G7R, SSDSC2BB150G7R, SSDSC2BB240G7R, SSDSC2BB480G7R, SSDSC2BB800G7R, SSDSC2BB960G7R, SSDSC2BB012T7R, SSDSC2BB016T7R, SSDSCKJB120G7R, SSDSCKJB150G7R, SSDSCKJB240G7R, SSDSCKJB480G7R, SSDSCKJB760G7R and SSDSCKJB960G7R.",
      "revision_history": "Fixes:\n-Numerous minor bug fixes\n-DUP package fixes Linux error when executing DUP package\n-Fix for some M.2 drives not upgrading\n\nEnhancements:\n-Added support for Instant Scramble Erase commands"
    },
    {
      "id": "125ffdbb52155cfb32cd1f30b80c06e0ace77a14ec9e8c624e23d2f24616dcc9",
      "name": "Samsung GD57 for model number(s) MZ7KM240HMHQ0D3, MZ7KM480HMHQ0D3, MZ7KM960HMJP0D3, MZ7KM1T9HMJP0D3.",
      "version": "GD57",
      "release_id": "97D8J",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T07:51:56Z",
      "released": "2018-03-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04918069M/2/Serial-ATA_Firmware_97D8J_WN64_GD57_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=97D8J",
      "size": 10195104,
      "reboot_required": false,
      "description": "This release contains firmware version GD57 for Samsung drives. Vendor model numbers MZ7KM240HMHQ0D3, MZ7KM480HMHQ0D3, MZ7KM960HMJP0D3, MZ7KM1T9HMJP0D3 and MZ7KM3T8HMLP0D3.",
      "revision_history": "Fixes: \n-Addresses rare case where drive will return uncorrectable read errors\n\nEnhancements:\n-Improves start up time after power on\n-Improved power loss protection"
    },
    {
      "id": "ea33e301f0bccfa657de7fc2030c09c0ca79f634d22a285a5d06df1d6fd6df8c",
      "name": "Toshiba AS0E for model number(s) PX05SMB320Y, PX05SMB160Y, PX05SMB080Y, PX05SMB040Y, PX05SVB384Y, PX05SVB192Y, PX05SVB096Y, PX05SVB048Y, PX05SRB384Y, PX05SRB192Y, PX05SRB096Y and PX05SRB048Y.",
      "version": "AS0E",
      "release_id": "0G2TK",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T04:16:29Z",
      "released": "2018-08-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05153780M/3/SAS-Drive_Firmware_0G2TK_WN64_AS0E_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0G2TK",
      "size": 10600424,
      "reboot_required": false,
      "description": "This release contains firmware version AS0E for Toshiba drives. Vendor model numbers PX05SMB320Y, PX05SMB160Y, PX05SMB080Y, PX05SMB040Y, PX05SVB384Y, PX05SVB192Y, PX05SVB096Y, PX05SVB048Y, PX05SRB384Y, PX05SRB192Y, PX05SRB096Y and PX05SRB048Y.",
      "revision_history": "Fixes\nn/a\n\nEnhancements\nn/a"
    },
    {
      "id": "4695419d23bdd78166088b177010e8fe91d8488323b8fe526201c4f263dd0af5",
      "name": "Toshiba EC02 for model number(s) AL13SXB30ENY and AL13SXB60ENY.",
      "version": "EC02",
      "release_id": "47FXP",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-27T18:19:16Z",
      "released": "2017-05-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04337050M/3/SAS-Drive_Firmware_47FXP_WN64_EC02_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=47FXP",
      "size": 9662008,
      "reboot_required": false,
      "description": "This release contains firmware version EC02 for Toshiba drives. Vendor model numbers AL13SXB30ENY and AL13SXB60ENY.",
      "revision_history": "Fixes:\n-Firmware fix for TASK SET FULL bug during multiport usage.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "04ec308a99971de5cff5f462337b720c363907e5555189bb9cfd4a864710fd66",
      "name": "Seagate NSF2 for model number(s) ST2000NX0453..",
      "version": "NSF2",
      "release_id": "1HWVN",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-21T08:24:58Z",
      "released": "2019-01-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05424349M/1/SAS-Drive_Firmware_1HWVN_WN64_NSF2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=1HWVN",
      "size": 10649408,
      "reboot_required": false,
      "description": "This release contains firmware version NSF2 for Seagate drives. Vendor model numbers ST2000NX0453..",
      "revision_history": "Fixes\n-improve compatibility with Linux OS after Sanitize Cryptographic Erase was performed\n-Fix issues where Command Timeout can result\n-Fix issues where Assert can result\n-Fix an issue where drive hang can result\n-Fix an issue where IOEDC error can result\n-Fix an issue where Current Mode Page values revert to Default values after power cycle\n\nEnhancements\n-Improve performance for specific workload cases\n-Improve status/reporting accuracy"
    },
    {
      "id": "b897b256e176b4489efbec8b5fcbb310a76fe24f985c77c3b0887e269c6df69c",
      "name": "Emulex Fibre Channel Adapter Firmware.",
      "version": "02.03.02",
      "release_id": "D76P7",
      "category": "Fibre Channel",
      "category_slug": "fibre-channel",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2018-02-21T22:55:02Z",
      "released": "2018-02-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04833204M/2/Fibre-Channel_Firmware_D76P7_WN64_02.03.02_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=D76P7",
      "size": 11418888,
      "reboot_required": true,
      "description": "Dell Update Package for updating firmware on the Emulex Fibre Channel adapters"
    },
    {
      "id": "e6e39e4184cbb12dc2ff0c4c4468eaab852e294621303d461998efeb88ea0e06",
      "name": "Intel DL53 for model number(s) SSDSC2KB240G7R, SSDSC2KB480G7R, SSDSC2KB960G7R, SSDSC2KB019T7R, SSDSC2KB038T7R, SSDSC2KB076T7R, SSDSC2KG240G7R, SSDSC2KG480G7R, SSDSC2KG960G7R, SSDSC2KG019T7R and SSDSC2KG038T7R.",
      "version": "DL53",
      "release_id": "K5N9H",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-09-28T03:20:57Z",
      "released": "2017-09-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04570591M/1/Serial-ATA_Firmware_K5N9H_WN64_DL53_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=K5N9H",
      "size": 9993464,
      "reboot_required": false,
      "description": "This release contains firmware version DL53 for Intel drives. Vendor model numbers SSDSC2KB240G7R, SSDSC2KB480G7R, SSDSC2KB960G7R, SSDSC2KB019T7R, SSDSC2KB038T7R, SSDSC2KB076T7R, SSDSC2KG240G7R, SSDSC2KG480G7R, SSDSC2KG960G7R, SSDSC2KG019T7R and SSDSC2KG038T7R.",
      "revision_history": "Initial release"
    },
    {
      "id": "927cd27db61fbf6fac072a8b6525b6b71727568693139fc3877ae53106995ea0",
      "name": "iDRAC Service Module Installer 3.0.2",
      "version": "3.0.2",
      "release_id": "WYH70",
      "category": "Systems Management",
      "category_slug": "systems-management",
      "importance": "Recommended",
      "type": "APAC",
      "posted": "2017-07-28T11:17:56Z",
      "released": "2017-07-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04457726M/1/Systems-Management_Application_WYH70_WN64_3.0.2_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WYH70",
      "size": 22164848,
      "reboot_required": false,
      "description": "The iDRAC Service Module is a lightweight optional software application that can be installed on Dell 12G Server or greater. The iDRAC Service Module complements iDRAC interfaces - Graphical User Interface (GUI), Remote Access Controller Admin (RACADM) CLI and Web Service Management (WSMAN) with additional monitoring data. You can configure the features on the supported operating system depending on the features to be installed and the unique integration needs in a customer environment."
    },
    {
      "id": "ba89c22f06f6473366af15ef453e922755d38745e08b4c2d870adb191fb6230a",
      "name": "Seagate NB33 for model number(s) ST2000NX0423 and ST1000NX0443.",
      "version": "NB33",
      "release_id": "GMW4P",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-06-24T16:18:33Z",
      "released": "2017-06-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04400574M/1/Serial-ATA_Firmware_GMW4P_WN64_NB33_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GMW4P",
      "size": 14393672,
      "reboot_required": false,
      "description": "This release contains firmware version NB33 for Seagate drives. Vendor model numbers ST2000NX0423 and ST1000NX0443.",
      "revision_history": "Fixes:\n-Fix an issue associated with reads after WRITE UNCORRECTABLE\n-Fix an issue where Assert condition can result\n\nEnhancements:\n-Improve the functionality associated with drive self\n-test execution\n-Improve status reporting/logging accuracy"
    },
    {
      "id": "dca5288c775e5dac78077a1c9907bca217d5786555001191f4d0d817f6c069fe",
      "name": "QLogic FastLinQ Network Device Firmware. Please note for the QLogic QL45212-DE 25 Gigabit Ethernet adapters, before upgrading the firmware to version 10.xx.xx the adapter must have firmware version 8.7.x or later.",
      "version": "10.01.00",
      "release_id": "7N5GW",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-06-22T21:18:49Z",
      "released": "2017-06-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04398033M/1/Network_Firmware_7N5GW_WN64_10.01.00_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7N5GW",
      "size": 13748648,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware to support new QLogic cards in the Dell 14G and SkyLinx Servers. This release should be used with the QLogic family version 20.01 device drivers.",
      "revision_history": "Initial Release"
    },
    {
      "id": "ffd0908378f0cbc223d9299492b898b299b91e298123bd644e200e4b86190245",
      "name": "Seagate SS81 for model number(s) TB2400MM0159..",
      "version": "SS81",
      "release_id": "YRY9K",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-06-16T19:22:59Z",
      "released": "2017-06-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04388796M/1/SAS-Drive_Firmware_YRY9K_WN64_SS81_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YRY9K",
      "size": 14780160,
      "reboot_required": false,
      "description": "This release contains firmware version SS81 for Seagate drives. Vendor model numbers TB2400MM0159..",
      "revision_history": "Initial release"
    },
    {
      "id": "ef64692d74ba8fb2ec0ee8c0c379d64bf3b96cc7ddc2cec4c60b106412f4b505",
      "name": "Intel DL42 for model number(s) SSDSC2BB120G7R, SSDSC2BB150G7R, SSDSC2BB240G7R, SSDSC2BB480G7R, SSDSC2BB800G7R, SSDSC2BB960G7R, SSDSC2BB012T7R, SSDSC2BB016T7R, SSDSCKJB120G7R, SSDSCKJB150G7R, SSDSCKJB240G7R, SSDSCKJB480G7R, SSDSCKJB760G7R and SSDSCKJB960G7R.",
      "version": "DL42",
      "release_id": "J7THN",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-04-14T19:39:25Z",
      "released": "2017-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04280523M/1/Serial-ATA_Firmware_J7THN_WN64_DL42_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J7THN",
      "size": 13980320,
      "reboot_required": false,
      "description": "This release contains firmware version DL42 for Intel drives. Vendor model numbers SSDSC2BB120G7R, SSDSC2BB150G7R, SSDSC2BB240G7R, SSDSC2BB480G7R, SSDSC2BB800G7R, SSDSC2BB960G7R, SSDSC2BB012T7R, SSDSC2BB016T7R, SSDSCKJB120G7R, SSDSCKJB150G7R, SSDSCKJB240G7R, SSDSCKJB480G7R, SSDSCKJB760G7R and SSDSCKJB960G7R.",
      "revision_history": "Fixes:\n-Numerous minor bug fixes\n\nEnhancements:\n-Added support for Instant Scramble Erase commands"
    },
    {
      "id": "5e817d88257ae6de08ddedf7176b0686768af8435f17a6889c3f5f056764cfe8",
      "name": "Dell 13G/14G Internal Dual SD Module",
      "version": "1.7",
      "release_id": "FF4WY",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-04-04T22:11:22Z",
      "released": "2017-04-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04262255M/1/Firmware_FF4WY_WN64_1.7_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=FF4WY",
      "size": 14865672,
      "reboot_required": true,
      "description": "Internal Dual SD Module Firmware Update",
      "revision_history": "Fixes:\n- Resolved defect where IDSDM fails to be detected when server is rebooted after running VMWare ESXi certification tests.\n- Disabled reporting of ERROR5 (Secondary Missing) in non-RAID mode.\n- Disallows writes to certain registers while a rebuild is happening, correcting misleading information reported to IDRAC.\n- Fixed potential defect in write protect function for 14G.\n- Updated configuration data checks at start up to be compatible to configuration data stored by IDSDM firmware version 15.  (*Note: There will be configuration loss when downgrading from version 1.4 to version 15.)\n- Updated to support larger SD card capacities, up to 1024 GB.\n- Added 3 strike I2C error recovery"
    },
    {
      "id": "ae315fe699655a2248855c31d61310758493144cd37f67c095ea133b7025440a",
      "name": "Seagate TSC6 for model number(s) ST1200MM0108..",
      "version": "TSC6",
      "release_id": "8457G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-03-29T16:15:17Z",
      "released": "2017-03-29T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04255185M/1/SAS-Drive_Firmware_8457G_WN64_TSC6_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8457G",
      "size": 14355816,
      "reboot_required": false,
      "description": "This release contains firmware version TSC6 for Seagate drives. Vendor model numbers ST1200MM0108..",
      "revision_history": "Fixes:\n-Fix an issue where 02/041B is reported to HARD_RESET during Sanitize operation\n-Fix an issue where HARD_RESET can be missed intermittently\n-Fix an issue where 03/31/00 can result on power cycle or power on\n-Set minimum allowed speed to 3Gb when max. allowed speed is 12Gb\n-Fix an issue where incorrect value for Current Phy Capabilities is returned after FW download\n-Fix an issue where SAS speed negotiation can fail shortly after power on\n-Fix an issue where drive transition to IDLE_A even when IDLE_A is disabled\n-Fix an issue where drive does not transition to expected power state within 60 sec\n-Fix an issue where SAS port stops responding duing rapid HARD_RESETs\n-Fix an issue where 04/44/00 is reported during seq. writes\n-Preserve all Persistent Reservation information through FW download\n-Fix issues related to Persistent Reservation feature support\n-Support Medium and Long Token in Method Call\n-Fix issues where assert event can result\n-Fix issues where command timeout can result\n-Fix an issue where IOEDC error can result\n-Fix an issue where bus hang event can result\n\nEnhancements:\n-Performance improvements for certain workload scenarios\n-Improve status reporting/logging accuracy\n-Improvements for general interface protocol compliance"
    },
    {
      "id": "4fbfe9a6dad569fce77de63403d506f7eadd69d383980ede0b527ff7b27c4f17",
      "name": "Seagate 2T51 for model number(s) ST1800MM0198..",
      "version": "2T51",
      "release_id": "5YH6J",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-02-17T21:55:39Z",
      "released": "2017-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04190540M/1/SAS-Drive_Firmware_5YH6J_WN64_2T51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=5YH6J",
      "size": 17138992,
      "reboot_required": false,
      "description": "This release contains firmware version 2T51 for Seagate drives. Vendor model numbers ST1800MM0198..",
      "revision_history": "Initial release"
    },
    {
      "id": "a4a85d64c2a0d119932848e41a3b06019d8b8062c1169f30f894f9b6d78a5cdf",
      "name": "Seagate UT71 for model number(s) ST1200MM0198..",
      "version": "UT71",
      "release_id": "W7K02",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-02-17T21:25:50Z",
      "released": "2017-02-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04190452M/1/SAS-Drive_Firmware_W7K02_WN64_UT71_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=W7K02",
      "size": 17010400,
      "reboot_required": false,
      "description": "This release contains firmware version UT71 for Seagate drives. Vendor model numbers ST1200MM0198..",
      "revision_history": "Initial release"
    },
    {
      "id": "e9c21c914cec9e29feea97274faa6f0682ddba38138802ba60ec0446f182e2cc",
      "name": "Samsung GD53 for model number(s) MZ7KM240HMHQ0D3, MZ7KM480HMHQ0D3, MZ7KM960HMJP0D3, MZ7KM1T9HMJP0D3.",
      "version": "GD53",
      "release_id": "MFWYR",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2016-12-08T06:44:58Z",
      "released": "2016-12-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04079304M/1/Serial-ATA_Firmware_MFWYR_WN64_GD53_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=MFWYR",
      "size": 14427496,
      "reboot_required": false,
      "description": "This release contains firmware version GD53 for Samsung drives. Vendor model numbers MZ7KM240HMHQ0D3, MZ7KM480HMHQ0D3, MZ7KM960HMJP0D3, MZ7KM1T9HMJP0D3 and MZ7KM3T8HMLP0D3.",
      "revision_history": "Initial release"
    },
    {
      "id": "96b2b9aa39f5d7775b91af4babbc1340a8e364fe4b8cd241b6d516e9c19558e7",
      "name": "QLogic FastLinQ Network Adapter Device Firmware.",
      "version": "08.07.26",
      "release_id": "82J79",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2016-11-22T15:51:57Z",
      "released": "2016-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04050287M/1/Network_Firmware_82J79_WN64_08.07.26_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=82J79",
      "size": 17187224,
      "reboot_required": true,
      "description": "This release provides updated network controller firmware for the QLogic FastLinQ (BCM57xx, BCM578xx and 45xxx) Network Adapters. This release should be used with the QLogic family version 20.0.0 device drivers.",
      "revision_history": "Fixes:\n- Unable to UEFI PXE boot Broadcom 57810 SFP NIC after firmware update to 08.07.25.\n- Unable to establish network connecting from LC in UEFI mode.\n\nEnhancements:\nNone"
    },
    {
      "id": "d195e072bd07ddf3b468199d0874a1a29566cdcabe7800727d80747c1d61537e",
      "name": "Samsung GC57 for model number(s) MZ7LM240HMHQ0D3, MZ7LM480HMHQ0D3, MZ7LM960HMJP0D3, MZ7LM1T9HMJP0D3 and MZ7LM3T8HMLP0D3.",
      "version": "GC57",
      "release_id": "H5P55",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2016-11-10T22:07:51Z",
      "released": "2016-11-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04026717M/1/SAS-Drive_Firmware_H5P55_WN64_GC57_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=H5P55",
      "size": 14427592,
      "reboot_required": false,
      "description": "This release contains firmware version GC57 for Samsung drives. Vendor model numbers MZ7LM240HMHQ0D3, MZ7LM480HMHQ0D3, MZ7LM960HMJP0D3, MZ7LM1T9HMJP0D3 and MZ7LM3T8HMLP0D3.",
      "revision_history": "Initial release"
    }
  ]
}
