  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "m1000e",
  "name": "M1000e",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge M1000e Urgent Updates",
  "filter": "urgent",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 3,
      "rss": "/m1000e/urgent/rss.xml",
      "api": "/api/m1000e/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 8,
      "rss": "/m1000e/recommended/rss.xml",
      "api": "/api/m1000e/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 2,
      "rss": "/m1000e/optional/rss.xml",
      "api": "/api/m1000e/optional"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 10,
      "rss": "/m1000e/sas-drive/rss.xml",
      "api": "/api/m1000e/sas-drive"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 3,
      "rss": "/m1000e/serial-ata/rss.xml",
      "api": "/api/m1000e/serial-ata"
    }
  ],
  "count": 3,
  "updates": [
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "47fc5bdf9bcedc992be25ba9e3d2d403bb7837cd51ad9c8a62efd1ffc5752bfa",
      "name": "Samsung PM883a RI SSDR, FW HG59 for model number(s) MZ7LH240HBHQAD3, MZ7LH480HBHQAD3, MZ7LH960HBJRAD3, MZ7LH1T9HALTAD3, MZ7LH3T8HALTAD3, and MZ7LH7T6HALAAD3.",
      "version": "HG59",
      "release_id": "J81VT",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-22T13:48:29Z",
      "released": "2023-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09869294M/2/Serial-ATA_Firmware_J81VT_WN64_HG59_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=J81VT",
      "size": 12999704,
      "reboot_required": false,
      "description": "This firmware updates the Vendor Name string from DELL  to SAMSUNG, along with other changes to improve drive functionality.  Version HG59 firmware for Samsung PM883a SATA SSDs, models MZ7LH240HBHQAD3 , MZ7LH480HBHQAD3, MZ7LH960HBJRAD3 , MZ7LH1T9HALTAD3 , MZ7LH3T8HALTAD3, and MZ7LH7T6HALAAD3.",
      "revision_history": "Fixes:\n-Reset Handling fix to ensure COMRESET completes in less than 1 second"
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    }
  ]
}