  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "m1000e",
  "name": "M1000e",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge M1000e SAS Drive Updates",
  "filter": "sas-drive",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 3,
      "rss": "/m1000e/urgent/rss.xml",
      "api": "/api/m1000e/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 8,
      "rss": "/m1000e/recommended/rss.xml",
      "api": "/api/m1000e/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 2,
      "rss": "/m1000e/optional/rss.xml",
      "api": "/api/m1000e/optional"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 10,
      "rss": "/m1000e/sas-drive/rss.xml",
      "api": "/api/m1000e/sas-drive"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 3,
      "rss": "/m1000e/serial-ata/rss.xml",
      "api": "/api/m1000e/serial-ata"
    }
  ],
  "count": 10,
  "updates": [
    {
      "id": "baa5cac92e3b072bd227668372c2c7520ed3e15c5a55003853c701aa0df1e8a2",
      "name": "HGST J17L for model number(s) HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "version": "J17L",
      "release_id": "0NKFF",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-05-31T05:53:56Z",
      "released": "2024-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11625826M/3/SAS-Drive_Firmware_0NKFF_WN64_J17L_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=0NKFF",
      "size": 12890680,
      "reboot_required": false,
      "description": "This release contains firmware version J17L for HGST drives. Vendor model numbers HUSMM3240ASS200, HUSMM3280ASS200, HUSMM3216ASS200, HUSMM3232ASS200, HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200 and HUSMR3232ASS200.",
      "revision_history": "External: FW update for HGST Bear Cove MLC 3WPD SAS HDD, Model numbers HUSMR3240ASS200, HUSMR3280ASS200, HUSMR3216ASS200, HUSMR3232ASS200.\nIncludes FW fix to free space buffer calculation to avoid a potential assert condition resulting in a self-initiated reset."
    },
    {
      "id": "983f07f8b979c631783bcb2755a0840c8737dd218cb3d3c0c0cd77a6ec586ce4",
      "name": "HGST firmware version K968. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "version": "K968",
      "release_id": "7HYHH",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-05-17T07:01:59Z",
      "released": "2024-05-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11630948M/1/SAS-Drive_Firmware_7HYHH_WN64_K968_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7HYHH",
      "size": 12553744,
      "reboot_required": false,
      "description": "This release contains firmware version K968  for HGST drives. Vendor model numbers WUSTM3240ASS200, WUSTM3280ASS200, WUSTM3216ASS200, WUSTR1596ASS200, WUSTR1519ASS200, WUSTR1538ASS200, WUSTR1576ASS200, WUSTR1515ASS200, WUSTR6440ASS200, WUSTR6480ASS200 and WUSTR6416ASS200.",
      "revision_history": "Fix potential premature wear-out issue on drives in certain system environments\n- Fix for Self-Initiated Reset after drive usage history log receives excessive entries"
    },
    {
      "id": "c8c5d76a815cfb98dc387f0961ace756466bb770c305f0b97b1586707188e5e5",
      "name": "HGST RS07 for Vela-AP SAS  ISE model number(s) HUS728T6TAL5200, HUS728T6TAL4200.",
      "version": "RS07",
      "release_id": "27MDM",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-03-28T10:48:25Z",
      "released": "2024-03-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11253344M/2/SAS-Drive_Firmware_27MDM_WN64_RS07_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=27MDM",
      "size": 13319184,
      "reboot_required": false,
      "description": "This release contains firmware version HGST RS07 for Vela-AP SAS  ISE model number(s) HUS728T6TAL5200, HUS728T6TAL4200.\nNew firmware includes fix for potential stale data condition.",
      "revision_history": "Fixes:\n- Fix potential stale data condition where data from a sequential write stream does not invalidate previous overlapping read data in cache.\n- Fix for potential command timeout due to payload burst size calculation difference.\n\nEnhancements:\n-N/A"
    },
    {
      "id": "0f251f411329cac60e438d19918025fee053e4a06ee0225b24b918396b72637f",
      "name": "Hitachi PU07 for Vela-A ISE model number(s) HUS726T4TALS200.",
      "version": "PU07",
      "release_id": "8W21G",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-03-28T10:31:41Z",
      "released": "2023-09-18T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10586429M/3/SAS-Drive_Firmware_8W21G_WN64_PU07_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8W21G",
      "size": 13437600,
      "reboot_required": false,
      "description": "This release contains firmware version PU07 for Hitachi Vela-A ISE drives - Vendor model number(s) HUS726T4TALS200.\nNew firmware includes fix for corner case drive degradation upon sudden power loss during FW download.",
      "revision_history": "Fixes:\n- Mitigate unrecoverable drive or degraded scenarios caused by sudden power loss events when NOR flash file system is being updated.\n- Fix for issues occurring after EPO due to incorrect processing of Write Splice correction.\n- Prevent legacy (non-fast) deferred download from corrupting the current fast download state of background firmware update."
    },
    {
      "id": "dc4d9b31b476ffc086c28441a7060b994ff12bd8c7791266534a46aca19bec06",
      "name": "Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "version": "B02A",
      "release_id": "CPP97",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Optional",
      "type": "FRMW",
      "posted": "2024-02-12T04:37:43Z",
      "released": "2024-02-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11252185M/1/SAS-Drive_Firmware_CPP97_WN64_B02A_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CPP97",
      "size": 12644544,
      "reboot_required": false,
      "description": "This release contains firmware version Kioxia Phoenix M5 (PM5) (RI) (MU) (WI) B02A for model number(s) KPM5XMUG3T20, KPM5XMUG1T60, KPM5XMUG800G, KPM5XMUG400G, KPM5XVUG7T68, KPM5XVUG3T84, KPM5XVUG3T20, KPM5XVUG1T92, KPM5XVUG1T60, KPM5XVUG960G, KPM5XVUG800G, KPM5XVUG480G, KPM5XVUG400G, KPM5XRUG7T68, KPM5XRUG3T84, KPM5XRUG1T92, KPM5XRUG960G, KPM5XRUG480G.",
      "revision_history": "Fixes: \n\nFix1:  \n- A) When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  B) FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.                                                                                                                                                                              \nFix 2:\n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\nFix 3:\n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "0f2aad04e3d715fe60af5cb8dca609f6a76e3d07ca5f0ab96be68d1f12b515a0",
      "name": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "version": "B326",
      "release_id": "7FV43",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T11:30:04Z",
      "released": "2024-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11166204M/1/SAS-Drive_Firmware_7FV43_WN64_B326_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7FV43",
      "size": 12699824,
      "reboot_required": false,
      "description": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "revision_history": "Fixes: \n\nFix1:  \n- When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  Fixed FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.\n                                                                                                                                                                                   \nFix 2: \n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\n\nFix 3: \n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "f9290eb3b74efc450be944a10ae52b87ef4989382da72c3cd6b1a85e58859631",
      "name": "Seagate 3D03  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "version": "3D03",
      "release_id": "NKGWD",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:03:59Z",
      "released": "2022-12-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09072701M/2/SAS-Drive_Firmware_NKGWD_WN64_3D03_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NKGWD",
      "size": 11993080,
      "reboot_required": false,
      "description": "This release contains firmware version 3D03 Seagate  for model number(s) XS960SE70114, XS1920SE70114, XS3840SE70114 and XS7680SE70114",
      "revision_history": "Fixes:\nFix the drive assert on UNMAP command when Task Set Full is reached.\nFix an issue that can make the drive return 0B/44 to all commands until power cycled.\nFix issues that can cause drive assert.\nFix issues that can cause command timeout.\nFix issues that can cause drive-not-ready, including the case that can happen after power-cycle.\nFix issues that can cause drive hang condition.\nEnhancements:\nImprove error logging/sense data reporting."
    },
    {
      "id": "3d03b79a4932e61da174dbaedbbed861fb4a9afcc96be3b6381d8a637e42b4cc",
      "name": "Toshiba B710 for model number(s) KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "version": "B710",
      "release_id": "NDG7N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-01-11T16:53:26Z",
      "released": "2023-11-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10785174M/2/SAS-Drive_Firmware_NDG7N_WN64_B710_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NDG7N",
      "size": 12004592,
      "reboot_required": false,
      "description": "This release contains firmware version Toshiba B710 for model number(s)KRM5XRUG960G, KRM5XRUG1T92, KRM5XRUG3T84, KRM5XRUG7T68, KRM5XVUG960G, KRM5XVUG1T92, KRM5XVUG3T84.",
      "revision_history": "Fixes: \n\nIssue: When host continues to issue write commands to a particular LBA area and the wear-leveling process is executed on a different area, the drive may encounter the following failure mode. Once a drive falls into this failure mode, it cannot be recovered by a power cycle.\nCause: This issue was introduced by applying the wear-leveling-related change in the previous firmware. The data buffer is used for data transfer during wear-leveling. Firmware may detect overflow of this data buffer during the refresh process or data transfer process if a read error happens on the block where wear-leveling is in progress. The drive goes into failure mode once the data buffer overflow is detected.\nFix: Fixed the FW to make consecutive Wear-Leveling processes not overlap each other to prevent the occurrence of data buffer overflow."
    },
    {
      "id": "f875af7d1dc9cbbd0280d3f296ca165a9f6a8fa0c0ee19dd062d716feba0db4d",
      "name": "Seagate SAS ST32000645SS and ST33000650SS RS16",
      "version": "RS16",
      "release_id": "568C9",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2014-04-30T16:07:54Z",
      "released": "2014-04-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER02170768M/1/SAS-Drive_Firmware_568C9_WN64_RS16_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=568C9",
      "size": 21420584,
      "reboot_required": false,
      "description": "This release contains firmware version RS16 for Seagate SAS (7.2K rpm 3.5 SAS) 2TB and 3TB Hard Drive. Dell. Vendor model number ST32000645SS and ST33000650SS.",
      "revision_history": "esolves potential background test failure caused by incorrect LBA calculation \nDell Mfg. test enhancements (DEFT)\nCorrects several issues where a drive hang or timeout conditions can result\nDrive error recovery FW improvements and enhancements\nMaintenance and health update"
    },
    {
      "id": "d542d437d08456787aa02e99ecf4b06a78c1c02c6b2099dc5e4fc8f74f99ee6d",
      "name": "Hitachi SAS HUS156030VLS600, HUS156045VLS600 and HUS156060VLS600 firmware version E774",
      "version": "E774",
      "release_id": "R15M0",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2014-04-17T19:49:58Z",
      "released": "2014-04-17T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER02144951M/1/SAS-Drive_Firmware_R15M0_WN64_E774_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=R15M0",
      "size": 21258560,
      "reboot_required": false,
      "description": "This release contains firmware version E774 for Hitachi SAS (10K rpm 3.5 SAS) 300GB, 450GB and 600GB Hard Drives. Dell. Vendor model numbers HUS156030VLS600, HUS156045VLS600 and HUS156060VLS600",
      "revision_history": "Correct Segmented Firmware Download bit setting\nUpdate VPD page and Mode pages to make them comply with latest Dell requirements\nUpdate VPD page 81h and DCh to report drive RPM\nFix an issue where Supported OpCodes can be reported incorrectly"
    }
  ]
}