  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "fc640",
  "name": "FC640",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge FC640 SAS RAID Updates",
  "filter": "sas-raid",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 38,
      "rss": "/fc640/urgent/rss.xml",
      "api": "/api/fc640/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 138,
      "rss": "/fc640/recommended/rss.xml",
      "api": "/api/fc640/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 57,
      "rss": "/fc640/optional/rss.xml",
      "api": "/api/fc640/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/fc640/bios/rss.xml",
      "api": "/api/fc640/bios"
    },
    {
      "slug": "chassis-system-management",
      "label": "Chassis System Management",
      "count": 1,
      "rss": "/fc640/chassis-system-management/rss.xml",
      "api": "/api/fc640/chassis-system-management"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/fc640/chipset/rss.xml",
      "api": "/api/fc640/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/fc640/diagnostics/rss.xml",
      "api": "/api/fc640/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/fc640/drivers-for-os-deployment/rss.xml",
      "api": "/api/fc640/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 28,
      "rss": "/fc640/express-flash-pcie-ssd/rss.xml",
      "api": "/api/fc640/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 16,
      "rss": "/fc640/fibre-channel/rss.xml",
      "api": "/api/fc640/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 3,
      "rss": "/fc640/firmware/rss.xml",
      "api": "/api/fc640/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/fc640/idrac/rss.xml",
      "api": "/api/fc640/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 50,
      "rss": "/fc640/network/rss.xml",
      "api": "/api/fc640/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 71,
      "rss": "/fc640/sas-drive/rss.xml",
      "api": "/api/fc640/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 2,
      "rss": "/fc640/sas-non-raid/rss.xml",
      "api": "/api/fc640/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 9,
      "rss": "/fc640/sas-raid/rss.xml",
      "api": "/api/fc640/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 43,
      "rss": "/fc640/serial-ata/rss.xml",
      "api": "/api/fc640/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/fc640/systems-management/rss.xml",
      "api": "/api/fc640/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/fc640/video/rss.xml",
      "api": "/api/fc640/video"
    }
  ],
  "count": 9,
  "updates": [
    {
      "id": "fd473c28f7250f2c6d18913dc3111f4d695b92c719953f933d5de9f4f624cd1b",
      "name": "Dell PERC H330 Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "NYKX7",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:21:18Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07211734M/4/SAS-RAID_Firmware_NYKX7_WN64_25.5.9.0001_A15_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=NYKX7",
      "size": 25051800,
      "reboot_required": true,
      "description": "Dell PERC H330 Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "5c912c46b71cf36439ff040f72dfd483a636caf6953566b7822e906ce3a8e030",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "version": "25.5.8.0001",
      "release_id": "WRF3Y",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:12:44Z",
      "released": "2020-09-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06547525M/4/SAS-RAID_Firmware_WRF3Y_WN64_25.5.8.0001_A16_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WRF3Y",
      "size": 25507720,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "revision_history": "Fixes:\n-Fixed an isolated issue where manually run controller self-diagnostics would trigger Event 13 (Controller cache discarded due to firmware version incompatibility) on the subsequent reboot.\n\nEnhancements:\n-Enhanced Background Initialization (BGI) and Consistency Check (CC) progress to reduce performance impact when progress is saved (checkpointed).\n  Previous behavior:\n    BGI/CC progress was saved to disk every 5 minutes, this disk access triggered I/O to pause and cache flush, causing a latency increase.\n   New behavior (as of 25.5.8.0001):\n    BGI/CC progress was saved to disk every 5 minutes if an operating system/driver is not loaded.\n          Note: H330 controllers will keep background operations paused while in HII, or until an OS is loaded.\n    When the firmware detects a driver loading, BGI/CC progress will be saved every 4 hours.\n    When a graceful shutdown is performed, the firmware will save progress as part of the shutdown procedure.\n    In the event of ungraceful shutdown/power loss progress will resume from the last saved checkpoint.\n          Note: Progress Events remain unchanged and will be observed at the same interval."
    },
    {
      "id": "493d6478a65cc15bfbb6c50488217952ef5f4c79a9bf9c593c18ece67ef5ed3e",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "700GG",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-05T16:45:15Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07217671M/3/SAS-RAID_Firmware_700GG_WN64_25.5.9.0001_A17_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=700GG",
      "size": 25505712,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "e030fecbf94eb9512ae1dfa4fb776046fd4612d06268cb14e6909c5d697489ae",
      "name": "BOSS-S1 Modular firmware",
      "version": "2.6.13.3025",
      "release_id": "F9F16",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-27T11:07:40Z",
      "released": "2023-03-03T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09214778M/11/SAS-RAID_Firmware_F9F16_WN64_2.6.13.3025_A08_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F9F16",
      "size": 23542872,
      "reboot_required": true,
      "description": "BOSS-S1 Modular ROM version 2.6.13.3025",
      "revision_history": "Fixes : HW Re-spin \nAddressed false M.2 failures reported due to thermal issues\n\nEnhancements : Added new SDID 0x2260 on BOSS-S1 controller"
    },
    {
      "id": "c262b14586cfb8f23d28fd4fce1526b82bc29af8589298cb407fb7b8956acf5b",
      "name": "Windows Server 2022 64bit driver for PERC S140 Controller",
      "version": "5.11.0.0003",
      "release_id": "85R54",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T17:21:48Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422921M/1/SAS-RAID_Driver_85R54_WN64_5.11.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=85R54",
      "size": 6633192,
      "reboot_required": true,
      "description": "Windows Server 2022 64bit driver for PERC S140 Controller"
    },
    {
      "id": "c1ad7f22b60acedb99114f7c68abbc599cad01da466bb6ed704a1888f7280388",
      "name": "Windows Server 2019 64bit driver for PERC S140 Controller",
      "version": "5.11.0.0003",
      "release_id": "P74H3",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T17:21:17Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422918M/1/SAS-RAID_Driver_P74H3_WN64_5.11.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P74H3",
      "size": 6632656,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S140 Controller"
    },
    {
      "id": "67bda91546d83723ea48e081e2a78720970c1f46c0852cb2960f5221dc5bf79c",
      "name": "PERC H840 Controller Firmware 51.16.0-4795",
      "version": "51.16.0-4795",
      "release_id": "4447J",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2024-02-21T23:50:59Z",
      "released": "2023-03-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09659740M/2/SAS-RAID_Firmware_4447J_WN64_51.16.0-4795_A17_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4447J",
      "size": 11917128,
      "reboot_required": true,
      "description": "This release updates the firmware residing on H840 controllers to package 51.16.0-4795",
      "revision_history": "- H840 firmware release required to support PowerVault MD2412, MD2424, and MD2460 Enclosures"
    },
    {
      "id": "0e605d9211bcd8a02a879473d78eea4e314ae0715828727db3f5114b6575d264",
      "name": "PERC H740P/H840/H745 RAID Controller Firmware 51.16.0-4076",
      "version": "51.16.0-4076",
      "release_id": "F3J22",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-21T23:49:16Z",
      "released": "2021-07-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07551659M/2/SAS-RAID_Firmware_F3J22_WN64_51.16.0-4076_A16_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F3J22",
      "size": 26112328,
      "reboot_required": true,
      "description": "This release updates the firmware residing on PERC H740P, H840, and H745 controllers to package 51.16.0-4076",
      "revision_history": "Fixes: \n\n    -Fixed issue where controller would fault on boot in systems with multiple backplanes.\n    -Fixed issue where Medium Errors found on drives were not reported during rebuilds and copybacks.\n    -Fixed issue where controller would fault during a firmware downgrade.\n    -Fixed issue where Bad PHY events were incorrectly reported.\n    -Fixed issue where SATA Drives where controller would take too long to timeout a link recovery on an unresponsive drive."
    },
    {
      "id": "54f45b3e3ed95a4734d61ae1b0410bd9bdf58b64e5d771908f77aaa00e5f2b20",
      "name": "Windows Server 2016 Driver 6.604.06.00 for PERC H330/H730/H730P/H830/H730P MX/FD33xD/FD33xS Controllers",
      "version": "6.604.06.00",
      "release_id": "T244W",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-02-19T07:08:49Z",
      "released": "2016-09-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER03940499M/11/SAS-RAID_Driver_T244W_WN64_6.604.06.00_A01_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=T244W",
      "size": 6848432,
      "reboot_required": true,
      "description": "Windows Server 2016 Driver 6.604.06.00 for PERC H330/H730/H730P/H830/H730P MX/FD33xD/FD33xS Controllers",
      "revision_history": "Fixes\n- N/A\n\nEnhancements\n-  Added 1MB I/O support for H730, H730P and H830 controllers."
    }
  ]
}