  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "dss8440",
  "name": "DSS8440",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge DSS8440 Recommended Updates",
  "filter": "recommended",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 4,
      "rss": "/dss8440/urgent/rss.xml",
      "api": "/api/dss8440/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 27,
      "rss": "/dss8440/recommended/rss.xml",
      "api": "/api/dss8440/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 10,
      "rss": "/dss8440/optional/rss.xml",
      "api": "/api/dss8440/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/dss8440/bios/rss.xml",
      "api": "/api/dss8440/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 1,
      "rss": "/dss8440/chipset/rss.xml",
      "api": "/api/dss8440/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/dss8440/diagnostics/rss.xml",
      "api": "/api/dss8440/diagnostics"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 1,
      "rss": "/dss8440/express-flash-pcie-ssd/rss.xml",
      "api": "/api/dss8440/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/dss8440/firmware/rss.xml",
      "api": "/api/dss8440/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/dss8440/idrac/rss.xml",
      "api": "/api/dss8440/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 7,
      "rss": "/dss8440/network/rss.xml",
      "api": "/api/dss8440/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 4,
      "rss": "/dss8440/sas-drive/rss.xml",
      "api": "/api/dss8440/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 1,
      "rss": "/dss8440/sas-non-raid/rss.xml",
      "api": "/api/dss8440/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 3,
      "rss": "/dss8440/sas-raid/rss.xml",
      "api": "/api/dss8440/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 20,
      "rss": "/dss8440/serial-ata/rss.xml",
      "api": "/api/dss8440/serial-ata"
    }
  ],
  "count": 27,
  "updates": [
    {
      "id": "4b5a01017f8b562fc6b7d52e9924eec86a633fd59edb7ddf4d945828910449e2",
      "name": "Dell Server DSS8440 BIOS Version 2.29.3",
      "version": "2.29.3",
      "release_id": "VT11H",
      "category": "BIOS",
      "category_slug": "bios",
      "importance": "Recommended",
      "type": "BIOS",
      "posted": "2026-10-28T05:26:41Z",
      "released": "2026-10-28T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15176107M/1/DSS8440_BIOS_VT11H_WN64_2.29.3.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VT11H",
      "size": 50922456,
      "reboot_required": true,
      "description": "For more information about specific items added and resolved in this BIOS version, see the Fixes and New and enhanced feature sections. If there's any security fix included in this BIOS, we'll address it in the BIOS external release note.",
      "revision_history": "Fixes:\nN/A\n\nNew and enhanced features:\n- This release contains security fixes that address one or more vulnerabilities. Dell recommends that you run the most recent available version of the software and apply any security updates at the earliest opportunity. Upon completion of coordinated vulnerability disclosure activities, Dell will publish a Dell Security Advisory (DSA) providing additional details about the vulnerabilities and associated security updates. Customers are encouraged to subscribe to Dell Security Advisories to receive notifications when advisories are published."
    },
    {
      "id": "5c912c46b71cf36439ff040f72dfd483a636caf6953566b7822e906ce3a8e030",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "version": "25.5.8.0001",
      "release_id": "WRF3Y",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-12T17:12:44Z",
      "released": "2020-09-30T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06547525M/4/SAS-RAID_Firmware_WRF3Y_WN64_25.5.8.0001_A16_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=WRF3Y",
      "size": 25507720,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.8.0001",
      "revision_history": "Fixes:\n-Fixed an isolated issue where manually run controller self-diagnostics would trigger Event 13 (Controller cache discarded due to firmware version incompatibility) on the subsequent reboot.\n\nEnhancements:\n-Enhanced Background Initialization (BGI) and Consistency Check (CC) progress to reduce performance impact when progress is saved (checkpointed).\n  Previous behavior:\n    BGI/CC progress was saved to disk every 5 minutes, this disk access triggered I/O to pause and cache flush, causing a latency increase.\n   New behavior (as of 25.5.8.0001):\n    BGI/CC progress was saved to disk every 5 minutes if an operating system/driver is not loaded.\n          Note: H330 controllers will keep background operations paused while in HII, or until an OS is loaded.\n    When the firmware detects a driver loading, BGI/CC progress will be saved every 4 hours.\n    When a graceful shutdown is performed, the firmware will save progress as part of the shutdown procedure.\n    In the event of ungraceful shutdown/power loss progress will resume from the last saved checkpoint.\n          Note: Progress Events remain unchanged and will be observed at the same interval."
    },
    {
      "id": "493d6478a65cc15bfbb6c50488217952ef5f4c79a9bf9c593c18ece67ef5ed3e",
      "name": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "version": "25.5.9.0001",
      "release_id": "700GG",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-05T16:45:15Z",
      "released": "2021-05-21T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07217671M/3/SAS-RAID_Firmware_700GG_WN64_25.5.9.0001_A17_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=700GG",
      "size": 25505712,
      "reboot_required": true,
      "description": "Dell PERC H730/H730P/H830/FD33xS/FD33xD Mini/Adapter RAID Controllers firmware version 25.5.9.0001",
      "revision_history": "Fixes\n- Fixed an isolated issue where a hot-plug drive was incorrectly set to non-RAID mode, causing auto-rebuild to not start automatically.\n- Fixed an issue with false XOR diagnostic test failures.\n- Fixed an issue with incorrect Disk Group number displayed for a hot spare in HII Physical Disk Management section.  \n\nEnhancements/Tasks\n- None"
    },
    {
      "id": "4175d48092d0c8309e216153c7b743dbea59b1590da4dedc03c2970bca816070",
      "name": "MICRON 5100 max Pro RI/ Pro boot M.2 SATA \u0026apos;L013\u0026apos; FW for model number(s) MTFDDAV240TCB, MTFDDAV480TCB, MTFDDAV960TCB, MTFDDAV1T9TCB, MTFDDAK240TCB, MTFDDAK480TCB, MTFDDAK960TCB, MTFDDAK1T9TCB",
      "version": "L013",
      "release_id": "RTND5",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-04T14:23:56Z",
      "released": "2026-08-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14983889M/1/Serial-ATA_Firmware_RTND5_WN64_L013_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RTND5",
      "size": 26470688,
      "reboot_required": true,
      "description": "This release contains firmware version L013 for MICRON model number(s) MTFDDAV240TCB, MTFDDAV480TCB, MTFDDAV960TCB, MTFDDAV1T9TCB, MTFDDAK240TCB, MTFDDAK480TCB, MTFDDAK960TCB, MTFDDAK1T9TCB.  Capacity of 5100 max Pro boot 240GB, 480GB, 960GB, 1.92TB. Pro RI 240GB, 480GB, 960GB and 1.92TB",
      "revision_history": "Fixes:\n1. D0DL013 addresses this issue.  The updated behavior will be:\n2. LogEntryCnt = 65,535 Exit the workload log function directly; no workload log entry is recorded.\n3. LogEntryCnt = 0 to 65,534 Workload log recording continues as originally designed."
    },
    {
      "id": "832f358867a87dbab42fc379e286da1d8bd7b8fd87d614862be22df1da90058d",
      "name": "Hynix SE5130 DG02 Firmware for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N",
      "version": "DG02",
      "release_id": "17C3M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-03-09T14:43:52Z",
      "released": "2025-11-12T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER14279570M/1/Serial-ATA_Firmware_17C3M_WN64_DG02_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=17C3M",
      "size": 25675424,
      "reboot_required": true,
      "description": "This is the initial firmware release of HYNIX, SE5130, DG02 for model numbers HFS480G3E2X149N, HFS960G3E2X149N, HFS1T9G3E2X149N, HFS3T8G3E2X149N.",
      "revision_history": "Fixes:\n\nFix1: Add a sequence to clear the \"health monitoring done bit\" every time before health monitoring is triggered.\nFix2: Device starts GC (enables flow control) with 4K random write. There is no performance drop with other workloads(Seq Read / Ran Read / Ran Write).The host should use the sanitize or TRIM(all ranges) instead of the secure erase or waits for GC finishing for a while. Category of Smart ID 245 (Percent Drive Life Remaining) is Pre-failure.\nFix3: Set the Category of Smart ID 245 (Percent Drive Life Remaining) to Advisory."
    },
    {
      "id": "ecea33696153990ad446eddf64bc3b31180d12bdb42af975eaf0ec0d89954e53",
      "name": "Samsung HK56 FW for PM897a SATA drive program for model number(s) MZ7L3480HELTAD3, MZ7L3960HELAAD3, MZ7L31T9HENAAD3, MZ7L33T8HENAAD3",
      "version": "HK56",
      "release_id": "KHC8M",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:55:37Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12607553M/2/Serial-ATA_Firmware_KHC8M_WN64_HK56_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=KHC8M",
      "size": 25015744,
      "reboot_required": false,
      "description": "This release contains firmware version HL56 for supplier model number(s)MZ7L3960HELTAD3, MZ7L31T9HELAAD3, MZ7L33T8HELAAD3, MZ7L37T6HELAAD3",
      "revision_history": "Fixes: \n\n- Disabled Send / Receive FPDMA for QTRIM commands\n- Disabled NCQ Non-Data commands\n- Addressed PLP Timeout / Error Mode by correcting LPage Handles hash algorithm\n- Improved Unmap policy during Sanitize\n- Altered Protective Reclaim (PR) operation to better manange hot-spot reads"
    },
    {
      "id": "3ba243687a1eef86fefe2f16237159b1933e93d3275f272b28076d00a05ae847",
      "name": "Samsung PM897 SATA SSDs for HH62 firmware for models MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "version": "HH62",
      "release_id": "Y4WVW",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-06-24T17:54:57Z",
      "released": "2025-01-31T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12519999M/3/Serial-ATA_Firmware_Y4WVW_WN64_HH62_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=Y4WVW",
      "size": 25286320,
      "reboot_required": false,
      "description": "This release contains firmware version Samsung HH62 for model number(s) MZ7L3480HBLTAD3, MZ7L3960HBLTAD3, MZ7L31T9HBNAAD3, and MZ7L33T8HBNAAD3",
      "revision_history": "Fixes: \n- Enhanced Reclaim Policy and reduced COMRST to 1 sec. to address PDL issue\n- Enhanced PLP/SNOR logging, to improve debuggability"
    },
    {
      "id": "fcb86d9b5e1472e571103417d19ca03e700321d4d92cd23bd7951fa87f4cae08",
      "name": "Samsung PM883a RI SSDR, FW HG60 for model number(s) MZ7LH240HBHQAD3, MZ7LH480HBHQAD3, MZ7LH960HBJRAD3, MZ7LH1T9HALTAD3, MZ7LH3T8HALTAD3, and MZ7LH7T6HALAAD3",
      "version": "HG60",
      "release_id": "107CV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2025-05-12T11:17:47Z",
      "released": "2025-04-14T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12756666M/3/Serial-ATA_Firmware_107CV_WN64_HG60_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=107CV",
      "size": 25011520,
      "reboot_required": false,
      "description": "This firmware update includes command updates, improvements in PLP timeout handling, and optimized controller logic to improve slow writes. version HG60 firmware for Samsung PM883a SATA SSDs models MZ7LH240HBHQAD3, MZ7LH480HBHQAD3, MZ7LH960HBJRAD3, MZ7LH1T9HALTAD3, MZ7LH3T8HALTAD3, and MZ7LH7T6HALAAD3",
      "revision_history": "- PLP Timeout Fix\n- Improved COMRST response (\u003c1 sec.)\n- Enhanced Reclaim policy to improve hot spot read reclam"
    },
    {
      "id": "ab13ae4fdb4fa0345532494866bbbc497d0ca9dccb6790c83aa34bdfdc8dc834",
      "name": "Samsung PM893 SATA SSDs for HJ62 firmware for models MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3",
      "version": "HJ62",
      "release_id": "537XV",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-12-24T13:41:29Z",
      "released": "2024-11-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER12519998M/1/Serial-ATA_Firmware_537XV_WN64_HJ62_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=537XV",
      "size": 13233416,
      "reboot_required": false,
      "description": "This release contains firmware version Samsung HJ62 for model number(s) MZ7L3480HCHQAD3, MZ7L3960HCJRAD3, MZ7L31T9HBLTAD3, MZ7L33T8HBLTAD3, and MZ7L37T6HBLAAD3.",
      "revision_history": "Fixes: \n\n- Enhanced Reclaim Policy and reduced COMRST to 1 sec. to address PDL issue.\n- Enhanced PLP/SNOR logging, to improve debuggability."
    },
    {
      "id": "baa0a7a037fed1c6f6eb64b86710485f7ff883213e4c229f8637e4729bad9f90",
      "name": "Dell 12Gbps HBA firmware version 16.17.00.05",
      "version": "16.17.00.05",
      "release_id": "20VY1",
      "category": "SAS Non-RAID",
      "category_slug": "sas-non-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-21T17:53:59Z",
      "released": "2019-07-01T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05653941M/4/SAS-Non-RAID_Firmware_20VY1_WN64_16.17.00.05_A09_03.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=20VY1",
      "size": 8671184,
      "reboot_required": true,
      "description": "Dell 12Gbps HBA firmware version 16.17.00.05",
      "revision_history": "Fixes\n-Fixed an issue that was causing periodic diagnostic resets which could ultimately lead to a failed drive, particularly in VSAN/VXRail environments. \n-Fixed an issue where mal-formed ATA passthrough commands could lead to command timeouts.\n-Fixed an issue where SCSI pass-through command timeouts could occur at 18-20 minute intervals in a VSAN environment.\n-Fixed an issue where a SATA link reset could cause many IOP Log events (31110e03) to be sent to the kernel log.\n-Fixed an issue in which a drive reset could lead to a false check condition with error 4/44/00.\n\nEnhancements\n-None"
    },
    {
      "id": "2b778bf7fdc239c077dc71367aad311fb6a2d15816fc43bf2c13899855ec3377",
      "name": "Non-expander Storage Backplane Firmware",
      "version": "4.35",
      "release_id": "VV85D",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T15:17:23Z",
      "released": "2019-08-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05772283M/10/Firmware_VV85D_WN64_4.35_A00_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VV85D",
      "size": 24118960,
      "reboot_required": true,
      "description": "Dell SEP Firmware for PowerEdge Servers with passive backplanes",
      "revision_history": "Firmware 4.35\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms/configurations.\n\n\n\nChange History:\n\nFirmware 4.32\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.29\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.27\nFixes:\n- Addressed minor bug related to NVMe device reporting\nEnhancements:\n- None\n\nFirmware 4.26\nFixes:\n- Addressed incorrect cable error reporting for PowerEdge R520 x12 passive backplane\nEnhancements:\n- Added new RAID controller support for PowerEdge R740XD 24x2.5\" NVMe backplane\n- Added supported for NVMe only configurations in PowerEdge R6425 10x2.5\" backplane\n\nFirmware 4.23\nFixes:\n- Addressed an issue with firmware roll-back when HBA controller is present.\nEnhancements:\n- Added support for NVMe drive type detect in supported backplanes.\n\nFirmware 4.18\nFixes:\n- None\nEnhancements:\n- Added drive LED management capability for SATA chipset connect configurations.\n- Added ability to report NVMe drive presence for system power and thermal management.\n\nFirmware 4.17\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.04\nFixes:\n- Addressed fixed Bay ID reporting in all NVMe drive configurations\nEnhancements:\n- None\n\nFirmware 3.62\nFixes:\n- Addressed potential backplane personality detection issue\nEnhancements:\n- None\n\nFirmware 3.58\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 3.56\n- Initial Release"
    },
    {
      "id": "6c992026ccb1034e5d76c43933dc44c2595da3c48f49b380535843c14de95847",
      "name": "Micron K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "version": "K003",
      "release_id": "RJ0WY",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-29T14:41:30Z",
      "released": "2023-12-05T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10606437M/2/Serial-ATA_Firmware_RJ0WY_WN64_K003_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=RJ0WY",
      "size": 12627936,
      "reboot_required": false,
      "description": "This release contains firmware version K003 for 5400 SATA, model number(s) MTFDDAV960TGA, MTFDDAV480TGA,MTFDDAV240TGC,MTFDDAK480TGB, MTFDDAK960TGB, MTFDDAK1T9TGB, MTFDDAK960TGA,  MTFDDAK1T9TGA, MTFDDAK240TGA, MTFDDAK480TGA, MTFDDAK960TGA,MTFDDAK1T9TGA.",
      "revision_history": "Fixes:\n\n-Fixes to address performance."
    },
    {
      "id": "0f2aad04e3d715fe60af5cb8dca609f6a76e3d07ca5f0ab96be68d1f12b515a0",
      "name": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "version": "B326",
      "release_id": "7FV43",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-23T11:30:04Z",
      "released": "2024-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11166204M/1/SAS-Drive_Firmware_7FV43_WN64_B326_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7FV43",
      "size": 12699824,
      "reboot_required": false,
      "description": "Kioxia Phoenix M5 (PM5) (MU FIPS) (RI FIPS) B326 for model numbers KPM5WRUG7T68, KPM5WRUG3T84, KPM5WVUG3T84, KPM5WVUG1T92, KPM5WVUG960G, KPM5WVUG480G, KPM5WVUG7T68",
      "revision_history": "Fixes: \n\nFix1:  \n- When a refresh operation or error recovery event is detected on the targeted Block of Wear-leveling, the execution priority is changed to high, and a refresh or error recovery process is carried out.    \n-  Fixed FW to determine the completion of the wear-leveling process correctly, then complete the Wear-leveling process.\n                                                                                                                                                                                   \nFix 2: \n- A fix to avoid the FW hang condition when 04-44-DC occurs so that PLP will run even if the drive is performing emergency GC.  \n- Power-on timeout limit extension from 5 minutes to 30 minutes to allow the drive the maximum amount of time to perform emergency GC to also prevent this assert.\n\nFix 3: \n- The New FW can monitor and normalize the free area unbalance among the bank groups. This FW will compare the number of free blocks among the multiple bank groups and will control the data source and data destination when garbage collection is activated."
    },
    {
      "id": "e476ba88da356bad67538ce06e54a64af28ea4c555ed2c8163226e0f77f448f0",
      "name": "Micron J008 SED firmware for model numbers MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS, MTFDDAK480TDT, MTFDDAK960TDT, and MTFDDAK1T9TDT.",
      "version": "J008",
      "release_id": "CX0H8",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:48:55Z",
      "released": "2023-09-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10433741M/2/Serial-ATA_Firmware_CX0H8_WN64_J008_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=CX0H8",
      "size": 11680080,
      "reboot_required": false,
      "description": "This release contains firmware version J008 for Micron SED RI  and MU family of drives (capacities of 1.92TB and lower). Drive model numbers MTFDDAK480TDS, MTFDDAK960TDS, MTFDDAK1T9TDS, MTFDDAK480TDT, MTFDDAK960TDT, and MTFDDAK1T9TDT.",
      "revision_history": "Fixes:\n-Fixes for FW assert issue and power loss handling issue."
    },
    {
      "id": "76b7116270b3cd4c1c9c86222e1f499696f02117527805b4d018abad824073c8",
      "name": "Intel Youngsville refresh DL6B for model number(s). SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R",
      "version": "DL6B",
      "release_id": "4DW70",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-01-22T13:45:55Z",
      "released": "2023-12-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10541168M/2/Serial-ATA_Firmware_4DW70_WN64_DL6B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4DW70",
      "size": 11740528,
      "reboot_required": false,
      "description": "This release contains firmware version DL6B for Intel drives. Vendor model numbers  SSDSC2KB240G8T, SSDSC2KB480G8T, SSDSC2KB960G8T, SSDSC2KB240G8R, SSDSC2KB480G8R, SSDSC2KB960G8R, SSDSC2KB019T8R, SSDSC2KB038T8R, SSDSC2KG240G8T, SSDSC2KG480G8T, SSDSC2KG960G8T, SSDSC2KG240G8R, SSDSC2KG480G8R, SSDSC2KG960G8R, SSDSC2KG019T8R,SSDSC2KG038T8R,SSDSC2KG076T8R,SSDSC2KB076T8R.",
      "revision_history": "Fixes:\n\n-  Fix for SMART attribute failure observed at power up.\n-  Fix for IO timeouts resulting in device failures."
    },
    {
      "id": "4e39b027cd0207a322b7a319adbf80cf4d89682de029c9a70a3aae037b5b09bd",
      "name": "Intel NIC Family Version 21.5.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "21.5.9",
      "release_id": "GXJ5G",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2022-09-13T21:56:31Z",
      "released": "2022-09-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER08981959M/1/Network_Firmware_GXJ5G_WN64_21.5.9_A02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GXJ5G",
      "size": 42687440,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Family Version 21.5.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance.",
      "revision_history": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Family Version 21.5.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "9ab63c70746d5dd9a103a2f0f482f09e5cca1b6a6ad91e5d34dc150ce2c2eadd",
      "name": "Intel NIC Family Version 19.5.0 Firmware for X710, XXV710, and XL710 adapters",
      "version": "19.5.12",
      "release_id": "YP4R0",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-12-10T19:47:12Z",
      "released": "2019-12-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05982966M/3/Network_Firmware_YP4R0_WN64_19.5.12_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YP4R0",
      "size": 36597528,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Family Version 19.5.x on Intel X710, XXV710, and XL710 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "58ae83486fd525a6d7fc92aba56631b2227f7de7e3c671e4c14af15dbbc4d976",
      "name": "Intel NIC Family Version 19.5.0 Firmware for I350, I354, X520, X540, and X550 adapters",
      "version": "19.5.12",
      "release_id": "40NTK",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-12-09T20:56:33Z",
      "released": "2019-12-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05982935M/1/Network_Firmware_40NTK_WN64_19.5.12_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=40NTK",
      "size": 15755136,
      "reboot_required": true,
      "description": "This software bundle includes the Dell EMC Update Package to install Intel NIC Firmware Family Version 19.5.x on Intel I350, I354, X520, X540, and X550 adapters. This release provides continued code optimization to improve performance."
    },
    {
      "id": "b19335ee0f91963c35729427508c89c7ddb6a8844c7d5d8deda1e768d454f90e",
      "name": "Dell firmware DUP for Qlogic 41xxx series adapters",
      "version": "15.01.00",
      "release_id": "VNC6M",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-10-15T15:31:01Z",
      "released": "2019-10-11T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05882120M/1/Network_Firmware_VNC6M_WN64_15.01.00_A00-00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VNC6M",
      "size": 7528536,
      "reboot_required": true,
      "description": "This software bundle includes the Dell Update Package to install QLogic Firmware on the following adapters \n\nQL41162-DE 10 Gigabit Ethernet\nQL41112-DE 10 Gigabit Ethernet\nQL41262-DE 25 Gigabit Ethernet\nQLogic 4x10GE QL41164HMRJ CNA \nQLogic 4x10GE QL41164HMCU CNA\nQLogic 2x25GE QL41262HMCU CNA\nQLogic 2x1GE+2x10GE QL41264HMCU CNA\nQLogic 2x1GE+2x10GE QL41162HMRJ CNA\nQLogic 4x10GE QL41164HxRJ CNA\nQLogic 4x10GE QL41164HFCU CNA\nQLogic 2x25GE QL41262HMKR CNA\nQLogic 2x25GE QL41232HMKR NIC\nQLogic 2x10GE QL41132HxRJ NIC\nQLogic 2x25GE QL41232HxCU NIC\nQLogic 2x25GE QL41232HQCU NIC\nQLogic_2x10GT QL41132HQRJ NIC\nQLogic 2x10GE QL41132HQCU NIC",
      "revision_history": "Fixes:\n-------\nFor a complete list of all the fixes in this release, please download EndUserReleaseNotes.pdf file under - QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page.\n\n\nEnhancements:\n------------------\nFor a complete list of Enhancements in this release, please download EndUserReleaseNotes.pdf file under - QLogic User's Guide for Fibre Channel Adapter, Converged Network Adapter and Intelligent Ethernet Adapters. This can be found under Network category of the Dell Drivers and Download Support web page."
    },
    {
      "id": "97b997b5808f09b98198880af522de35124e873e5c543cc42d469365844e29cb",
      "name": "Seagate ST33 for model number(s) ST600MM0069 and ST1200MM0099.",
      "version": "ST33",
      "release_id": "89M5N",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-09-12T19:45:40Z",
      "released": "2018-12-13T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05368803M/2/SAS-Drive_Firmware_89M5N_WN64_ST33_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=89M5N",
      "size": 10764592,
      "reboot_required": false,
      "description": "This release contains firmware version ST33 for Seagate drives. Vendor model numbers ST600MM0069 and ST1200MM0099.",
      "revision_history": "Fixes\n-Improve compatibility after Sanitize Crypto Erase was performed\n-Fix issues where drive hang condition can result\n-Fix issues where assert condition can result\n-Fix issues where IOEDC error can result\n-Fix issues where command timeout can result\n-Fix various bugs\n-Fix the LED blink rate for Sanitize and FORMAT\n\nEnhancements\n-Improve status/reporting accuracy"
    },
    {
      "id": "c4f5eaf74915ebc2450700d065c6cf9112dfeadc8b0798e639d891f1559ee827",
      "name": "Mellanox ConnectX-4 Ethernet Adapter Firmware",
      "version": "12.25.10.20",
      "release_id": "G1F0Y",
      "category": "Network",
      "category_slug": "network",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-07-10T20:11:34Z",
      "released": "2019-05-06T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05727012M/1/Network_Firmware_G1F0Y_WN64_12.25.10.20.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=G1F0Y",
      "size": 15583832,
      "reboot_required": true,
      "description": "This package provides the Firmware update for Mellanox ConnectX-4 Dual Port 100 GbE Ethernet QSFP Network Adapter",
      "revision_history": "Fixes: \n-  Fixed a rare issue that caused the QP to falsely transition into the error state as a result of handling duplicate read/atomic request followed by memory key invalidation.\n-  Fixed an issue that prevented the user to enable the port after disabling it in the VF NODNIC. \n-  Enlarged the number of modify fields to 16 to avoid IPv6 header rewrite failure. \n\nEnhancements:\n- VSC security includes the mechanisms which will prevent a reasonable host from affecting other hosts from using VSC.\n- Zero touch RoCE enables RoCE to operate on fabrics where no PFC nor ECN are configured. This makes RoCE configuration a breeze while still maintaining its superior high performance\n- Added support for send opcode operations targeting a SRQ/RMP with the receive WQEs using ODP memory. In case the receive WQE receives an ODP, the device will generate ODP notifications (EQE) and PFAULT will abort CQEs.\nNote: It is recommended to prefetch the memory used by the receive WQEs to reduce ODP occurrence as these have significant latencies and will cause a performance degradation.\n- Firmware Burning using DMA Pages - This new capability accelerates the firmware burning process by using Direct Memory Access (DMA) pages.\n- Auto-Sensing when using 25/10GbE Optical Modules - This new capability accelerates the network to auto-sense the port speed and use it when using a 25/10GbE optical module. Meaning, if the used module is 25GbE but the port is a 10GbE port, the speed used for that network will be 10GbE.\n- Enabled Package ID configuration using server strap according OCP 3.0.\n- DPDK UIO - This capability provides a solution for improving user space drivers development, generic user space IO device services.\n- Renamed the BOOT_RETRY_CNT1 parameter to BOOT_RETRY_CNT."
    },
    {
      "id": "3d900a2b91705b372b84d0e773e701b354420444eee42275a87ef209f9afe1cb",
      "name": "WDC/HGST Bear Cove TLC RI, SSD, 12Gbps SAS, 2.5, 512e, ISE, FW S524 for model number(s) HUSTR7648ASS200, HUSTR7696ASS200, HUSTR7619ASS200, HUSTR7638ASS200 and HUSTR7676ASS200.",
      "version": "S524",
      "release_id": "PTK2C",
      "category": "SAS Drive",
      "category_slug": "sas-drive",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-31T03:42:36Z",
      "released": "2018-06-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05040652M/3/SAS-Drive_Firmware_PTK2C_WN64_S524_A00_02.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=PTK2C",
      "size": 10893512,
      "reboot_required": false,
      "description": "This release contains firmware version S524 for WDC/HGST Bear Cove TLC RI, SSD, 12Gbps SAS, 2.5, 512e, ISE.. Vendor model numbers HUSTR7648ASS200, HUSTR7696ASS200, HUSTR7619ASS200, HUSTR7638ASS200 and HUSTR7676ASS200.",
      "revision_history": "Fixes\n- Addressed power-off Data Retention issue in Intel TLC NAND.\n- Updated Pin 11 OOB Temperature monitoring algorithm.\n- Corrected VPD page settings for multi-initiator firmware download.\n\nEnhancements\nn/a"
    },
    {
      "id": "4b8929602c25e1472854373f4c91a7bd75d7fcdd2bc1528574c0ce8ff19302e6",
      "name": "Samsung PM883 RI SSDR, FW HE57 for model number(s) MZ7LH240HAHQ0D3, MZ7LH480HAHQ0D3, MZ7LH960HAJR0D3, MZ7LH1T9HMLT0D3, MZ7LH3T8HMLT0D3, and MZ7LH7T6HMLA0D3.",
      "version": "HE57",
      "release_id": "4DN2V",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-31T02:48:06Z",
      "released": "2019-01-23T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05441565M/1/Serial-ATA_Firmware_4DN2V_WN64_HE57_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=4DN2V",
      "size": 11979000,
      "reboot_required": false,
      "description": "This release contains firmware version HE57 for Samsung PM883 RI SSDR,  for model number(s) MZ7LH240HAHQ0D3, MZ7LH480HAHQ0D3, MZ7LH960HAJR0D3, MZ7LH1T9HMLT0D3, MZ7LH3T8HMLT0D3, and MZ7LH7T6HMLA0D3.",
      "revision_history": "Fixes\n -Addresses performance drop issue observed during workload transistions.  \n -Prevents incorrect entry into error state\n\nEnhancements\n -Improvements to quailty of service (QoS) via performance tuning"
    },
    {
      "id": "a34cdcfc5e6d92ca876fde3f6ae566e7cd07bbb5d8a4ec43d16cfdbafa67a8c9",
      "name": "Samsung GC5B for model number(s) MZ7LM240HMHQ0D3, MZ7LM480HMHQ0D3, MZ7LM960HMJP0D3, MZ7LM1T9HMJP0D3 and MZ7LM3T8HMLP0D3.",
      "version": "GC5B",
      "release_id": "P2YRJ",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-30T19:40:27Z",
      "released": "2018-03-22T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04918034M/2/Serial-ATA_Firmware_P2YRJ_WN64_GC5B_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P2YRJ",
      "size": 10201336,
      "reboot_required": false,
      "description": "This release contains firmware version GC5B for Samsung drives. Vendor model numbers MZ7LM240HMHQ0D3, MZ7LM480HMHQ0D3, MZ7LM960HMJP0D3, MZ7LM1T9HMJP0D3 and MZ7LM3T8HMLP0D3.",
      "revision_history": "Fixes:\n-Addresses rare case where drive will return uncorrectable read errors\n\nEnhancements:\n-Improves start up time after power on\n-Improved power loss protection"
    },
    {
      "id": "da3739cb33ef70d7490881a5e0bd244d80daeaf612233418b9201ae54c68b12e",
      "name": "Intel DL5A for model number(s) SSDSC2KB240G7R, SSDSC2KB480G7R, SSDSC2KB960G7R, SSDSC2KB019T7R, SSDSC2KB038T7R, SSDSC2KG240G7R, SSDSC2KG480G7R, SSDSC2KG960G7R, SSDSC2KG019T7R.",
      "version": "DL5A",
      "release_id": "YMFT2",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-25T06:59:34Z",
      "released": "2019-01-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05434040M/1/Serial-ATA_Firmware_YMFT2_WN64_DL5A_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=YMFT2",
      "size": 10540136,
      "reboot_required": false,
      "description": "This release contains firmware version DL5A for Intel drives. Vendor model numbers SSDSC2KB240G7R, SSDSC2KB480G7R, SSDSC2KB960G7R, SSDSC2KB019T7R, SSDSC2KB038T7R, SSDSC2KG240G7R, SSDSC2KG480G7R, SSDSC2KG960G7R, SSDSC2KG019T7R."
    },
    {
      "id": "c98d9a80b70357af7a5e32f932724126c0b82aae892927958aab0adb6b897cb8",
      "name": "MICRON 5200 RI/ MU  SATA \u0026apos;F000\u0026apos; FW for model number(s) MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, MTFDDAK1T9TDN, MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD.",
      "version": "F000",
      "release_id": "512NH",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2019-01-21T09:40:40Z",
      "released": "2018-12-10T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05424616M/1/Serial-ATA_Firmware_512NH_WN64_F000_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=512NH",
      "size": 10604648,
      "reboot_required": false,
      "description": "MICRON 5200 RI/ MU  SATA 'F000' FW for model number(s) MTFDDAK240TDN, MTFDDAK480TDN, MTFDDAK960TDN, MTFDDAK1T9TDN, MTFDDAK480TDC, MTFDDAK960TDD, MTFDDAK1T9TDD.",
      "revision_history": "Initial Firmware"
    },
    {
      "id": "ba89c22f06f6473366af15ef453e922755d38745e08b4c2d870adb191fb6230a",
      "name": "Seagate NB33 for model number(s) ST2000NX0423 and ST1000NX0443.",
      "version": "NB33",
      "release_id": "GMW4P",
      "category": "Serial ATA",
      "category_slug": "serial-ata",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2017-06-24T16:18:33Z",
      "released": "2017-06-24T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER04400574M/1/Serial-ATA_Firmware_GMW4P_WN64_NB33_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=GMW4P",
      "size": 14393672,
      "reboot_required": false,
      "description": "This release contains firmware version NB33 for Seagate drives. Vendor model numbers ST2000NX0423 and ST1000NX0443.",
      "revision_history": "Fixes:\n-Fix an issue associated with reads after WRITE UNCORRECTABLE\n-Fix an issue where Assert condition can result\n\nEnhancements:\n-Improve the functionality associated with drive self\n-test execution\n-Improve status reporting/logging accuracy"
    }
  ]
}