{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "c6620",
  "name": "C6620",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge C6620 iDRAC Updates",
  "filter": "idrac",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 25,
      "rss": "/c6620/urgent/rss.xml",
      "api": "/api/c6620/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 88,
      "rss": "/c6620/recommended/rss.xml",
      "api": "/api/c6620/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 54,
      "rss": "/c6620/optional/rss.xml",
      "api": "/api/c6620/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/c6620/bios/rss.xml",
      "api": "/api/c6620/bios"
    },
    {
      "slug": "boss",
      "label": "BOSS",
      "count": 2,
      "rss": "/c6620/boss/rss.xml",
      "api": "/api/c6620/boss"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/c6620/chipset/rss.xml",
      "api": "/api/c6620/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/c6620/diagnostics/rss.xml",
      "api": "/api/c6620/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/c6620/drivers-for-os-deployment/rss.xml",
      "api": "/api/c6620/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 46,
      "rss": "/c6620/express-flash-pcie-ssd/rss.xml",
      "api": "/api/c6620/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 8,
      "rss": "/c6620/fibre-channel/rss.xml",
      "api": "/api/c6620/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/c6620/firmware/rss.xml",
      "api": "/api/c6620/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/c6620/idrac/rss.xml",
      "api": "/api/c6620/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 32,
      "rss": "/c6620/network/rss.xml",
      "api": "/api/c6620/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 24,
      "rss": "/c6620/sas-drive/rss.xml",
      "api": "/api/c6620/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 10,
      "rss": "/c6620/sas-non-raid/rss.xml",
      "api": "/api/c6620/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 16,
      "rss": "/c6620/sas-raid/rss.xml",
      "api": "/api/c6620/sas-raid"
    },
    {
      "slug": "security",
      "label": "Security",
      "count": 1,
      "rss": "/c6620/security/rss.xml",
      "api": "/api/c6620/security"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 18,
      "rss": "/c6620/serial-ata/rss.xml",
      "api": "/api/c6620/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/c6620/systems-management/rss.xml",
      "api": "/api/c6620/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/c6620/video/rss.xml",
      "api": "/api/c6620/video"
    }
  ],
  "count": 1,
  "updates": [
    {
      "id": "fd0732c1a5436e1e87e2f3b578749cbde7f0ad1acade4f2c68a4395a4ec03d68",
      "name": "iDRAC 7.30.65.51",
      "version": "7.30.65.51",
      "release_id": "77JC4",
      "category": "iDRAC with Lifecycle Controller",
      "category_slug": "idrac-with-lifecycle-controller",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-10-26T15:08:42Z",
      "released": "2026-10-26T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER15169022M/1/iDRAC-with-Lifecycle-Controller_Firmware_77JC4_WN64_7.30.65.51_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=77JC4",
      "size": 244930552,
      "reboot_required": false,
      "description": "The Integrated Dell Remote Access Controller (iDRAC) is designed to make server administrators more productive and improve the overall availability of Dell servers. iDRAC also provides an out-of-band mechanism for configuring the platform, applying firmware updates, saving or restoring a system backup, or deploying an operating system, either by using a GUI or a remote scripting language, such as Redfish or RACADM.",
      "revision_history": "Fixes:\n- Fixes the issue where email alert is not enabled for LCS0009 event on PowerEdge XE8640 systems.\n- Fixes the issue where RAC1195 events for local user account deletion are missing in iDRAC9 releases by instrumenting the user deletion endpoint to generate audit logs.\n- Fixes the issue where Active Directory authentication fails due to DNS Type = ANY by changing the DNS query from T_ANY to T_SRV to comply with RFC8482.\n- Fixes the issue where CPU throttling occurs when PSU power input drops on PowerEdge T550 systems since iDRAC 7.20.30.00 by addressing the power FTR loop issue.\n- Fixes the issue where firmware update notifications on homepage use cached recommended updates by addressing the deletion of lc_validator_output.xml during iDRAC reboot or system erase operation.\n- Fixes the issue where fan failures occur on PowerScale R660 nodes after firmware updates by addressing the timing issue between BIOS updates and fan initialization.\n\nEnhancements:\n- Made Subject Alternative Name (SAN) mandatory for SSL/TLS CSR generation in iDRAC9.\n- Upgraded Poky for iDRAC9 16G.\n- Upgraded kernel to version 6.12.63 for iDRAC9 16G.\n- Added SMTP modern authentication (OAuth2) support for iDRAC9 16G.\n- Added TPM PCR Measurements reporting in Redfish for iDRAC9.\n- Added new option \"LCLOG\" in SystemErase for clearing LC logs without host reboot.\n- Added China Data Sanitization Compliance with Block Erase support on drives via iDRAC for 16G.\n- Leveraged iDRAC Early Video for Services Modernization on 16G.\n- Optimized 16G CPLD Firmware Update for Services Modernization.\n- Implemented correct and reliable Redfish StartUpdate action for 16G.\n- Enabled optional auto deletion of completed/failed iDRAC Jobs for 16G.\n- Enabled CPLD and iDRAC firmware updates with a single iDRAC reboot for 16G.\n- Added option to block downgrades in Automatic Updates to align with Manual Updates behavior for 16G.\n- Enabled sensor hot and system thermal shutdown information from thermal test utility and LC message for 16G.\n- Added Leak Warranty Void Warning Message support for iDRAC platforms 16G.\n- Updated OID for SCV replacement certificate on 16G/15G platforms.\n- Added security (firmware) assertions from iDRAC9 to SCV certificate.\n- Added iDRAC persistence and reconciliation capability for SCV Delta Certificate upload synchronization.\n- Enabled email alerts for thermal-related GPU/TMP events for 16G.\n- Enabled iLKM support on PowerEdge XR8620t.\n- Added Microsoft Entra ID (formerly Azure AD) support for OpenID Connect for 16G.\n- Migrated iDRAC9 GUI from AngularJS to Angular Framework for 16G.\n- Addressed Channel Firmware SED integration and stability issues for 16G.\n- Updated Redfish specification and schema for the 16G March release.\n- Implemented Redfish FullPowerCycle ResetType under ComputerSystem per DMTF specification for iDRAC9.\n- Enabled IPv6 Link-Local Address support with Zone ID for Zero Touch Bootstrap for 16G.\n- Fixed BootProgress/LastState property value showing as \"OSRunning\" when the server is not booted to the operating system.\n- Improved SEKM key retrieval retry and logging.\n- Added iDRAC uptime to sysinfo for 16G.\n- Added GetBIOSTime functionality and SetBIOSTime handling for unsupported BIOS for 16G.\n- Exposed Redfish APIs for Hardware Configuration Validation control in iDRAC for 16G.\n- Added support for SID/OPAL/PSID drive status property.\n- Added SDPM Battery Inventory and BBU Replacement Behavior for 16G."
    }
  ]
}
