{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:38.027872357Z"
  },
  "model": "c6420",
  "name": "C6420",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge C6420 Firmware Updates",
  "filter": "firmware",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 52,
      "rss": "/c6420/urgent/rss.xml",
      "api": "/api/c6420/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 181,
      "rss": "/c6420/recommended/rss.xml",
      "api": "/api/c6420/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 60,
      "rss": "/c6420/optional/rss.xml",
      "api": "/api/c6420/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/c6420/bios/rss.xml",
      "api": "/api/c6420/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/c6420/chipset/rss.xml",
      "api": "/api/c6420/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 2,
      "rss": "/c6420/diagnostics/rss.xml",
      "api": "/api/c6420/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/c6420/drivers-for-os-deployment/rss.xml",
      "api": "/api/c6420/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 35,
      "rss": "/c6420/express-flash-pcie-ssd/rss.xml",
      "api": "/api/c6420/express-flash-pcie-ssd"
    },
    {
      "slug": "fibre-channel",
      "label": "Fibre Channel",
      "count": 3,
      "rss": "/c6420/fibre-channel/rss.xml",
      "api": "/api/c6420/fibre-channel"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 1,
      "rss": "/c6420/firmware/rss.xml",
      "api": "/api/c6420/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/c6420/idrac/rss.xml",
      "api": "/api/c6420/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 54,
      "rss": "/c6420/network/rss.xml",
      "api": "/api/c6420/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 102,
      "rss": "/c6420/sas-drive/rss.xml",
      "api": "/api/c6420/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 6,
      "rss": "/c6420/sas-non-raid/rss.xml",
      "api": "/api/c6420/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 16,
      "rss": "/c6420/sas-raid/rss.xml",
      "api": "/api/c6420/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 66,
      "rss": "/c6420/serial-ata/rss.xml",
      "api": "/api/c6420/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/c6420/systems-management/rss.xml",
      "api": "/api/c6420/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/c6420/video/rss.xml",
      "api": "/api/c6420/video"
    }
  ],
  "count": 1,
  "updates": [
    {
      "id": "2b778bf7fdc239c077dc71367aad311fb6a2d15816fc43bf2c13899855ec3377",
      "name": "Non-expander Storage Backplane Firmware",
      "version": "4.35",
      "release_id": "VV85D",
      "category": "Firmware",
      "category_slug": "firmware",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-07T15:17:23Z",
      "released": "2019-08-07T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER05772283M/10/Firmware_VV85D_WN64_4.35_A00_09.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=VV85D",
      "size": 24118960,
      "reboot_required": true,
      "description": "Dell SEP Firmware for PowerEdge Servers with passive backplanes",
      "revision_history": "Firmware 4.35\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms/configurations.\n\n\n\nChange History:\n\nFirmware 4.32\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.29\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.27\nFixes:\n- Addressed minor bug related to NVMe device reporting\nEnhancements:\n- None\n\nFirmware 4.26\nFixes:\n- Addressed incorrect cable error reporting for PowerEdge R520 x12 passive backplane\nEnhancements:\n- Added new RAID controller support for PowerEdge R740XD 24x2.5\" NVMe backplane\n- Added supported for NVMe only configurations in PowerEdge R6425 10x2.5\" backplane\n\nFirmware 4.23\nFixes:\n- Addressed an issue with firmware roll-back when HBA controller is present.\nEnhancements:\n- Added support for NVMe drive type detect in supported backplanes.\n\nFirmware 4.18\nFixes:\n- None\nEnhancements:\n- Added drive LED management capability for SATA chipset connect configurations.\n- Added ability to report NVMe drive presence for system power and thermal management.\n\nFirmware 4.17\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 4.04\nFixes:\n- Addressed fixed Bay ID reporting in all NVMe drive configurations\nEnhancements:\n- None\n\nFirmware 3.62\nFixes:\n- Addressed potential backplane personality detection issue\nEnhancements:\n- None\n\nFirmware 3.58\nFixes:\n- None\nEnhancements:\n- Added support for additional PowerEdge platforms.\n\nFirmware 3.56\n- Initial Release"
    }
  ]
}
