{
  "catalog": {
    "version": "26.11.23",
    "release_id": "VTXX2",
    "published": "2026-11-23T08:48:06Z",
    "modified": "2026-11-23T09:46:27Z",
    "fetched": "2026-11-25T00:00:35.829701845Z"
  },
  "model": "c4140",
  "name": "C4140",
  "brand": "PowerEdge",
  "title": "Dell PowerEdge C4140 SAS RAID Updates",
  "filter": "sas-raid",
  "filters": [
    {
      "slug": "urgent",
      "label": "Urgent",
      "count": 16,
      "rss": "/c4140/urgent/rss.xml",
      "api": "/api/c4140/urgent"
    },
    {
      "slug": "recommended",
      "label": "Recommended",
      "count": 61,
      "rss": "/c4140/recommended/rss.xml",
      "api": "/api/c4140/recommended"
    },
    {
      "slug": "optional",
      "label": "Optional",
      "count": 27,
      "rss": "/c4140/optional/rss.xml",
      "api": "/api/c4140/optional"
    },
    {
      "slug": "bios",
      "label": "BIOS",
      "count": 1,
      "rss": "/c4140/bios/rss.xml",
      "api": "/api/c4140/bios"
    },
    {
      "slug": "chipset",
      "label": "Chipset",
      "count": 2,
      "rss": "/c4140/chipset/rss.xml",
      "api": "/api/c4140/chipset"
    },
    {
      "slug": "diagnostics",
      "label": "Diagnostics",
      "count": 1,
      "rss": "/c4140/diagnostics/rss.xml",
      "api": "/api/c4140/diagnostics"
    },
    {
      "slug": "drivers-for-os-deployment",
      "label": "Drivers for OS Deployment",
      "count": 1,
      "rss": "/c4140/drivers-for-os-deployment/rss.xml",
      "api": "/api/c4140/drivers-for-os-deployment"
    },
    {
      "slug": "express-flash-pcie-ssd",
      "label": "Express Flash PCIe SSD",
      "count": 6,
      "rss": "/c4140/express-flash-pcie-ssd/rss.xml",
      "api": "/api/c4140/express-flash-pcie-ssd"
    },
    {
      "slug": "firmware",
      "label": "Firmware",
      "count": 2,
      "rss": "/c4140/firmware/rss.xml",
      "api": "/api/c4140/firmware"
    },
    {
      "slug": "idrac",
      "label": "iDRAC",
      "count": 1,
      "rss": "/c4140/idrac/rss.xml",
      "api": "/api/c4140/idrac"
    },
    {
      "slug": "network",
      "label": "Network",
      "count": 29,
      "rss": "/c4140/network/rss.xml",
      "api": "/api/c4140/network"
    },
    {
      "slug": "sas-drive",
      "label": "SAS Drive",
      "count": 14,
      "rss": "/c4140/sas-drive/rss.xml",
      "api": "/api/c4140/sas-drive"
    },
    {
      "slug": "sas-non-raid",
      "label": "SAS Non-RAID",
      "count": 2,
      "rss": "/c4140/sas-non-raid/rss.xml",
      "api": "/api/c4140/sas-non-raid"
    },
    {
      "slug": "sas-raid",
      "label": "SAS RAID",
      "count": 8,
      "rss": "/c4140/sas-raid/rss.xml",
      "api": "/api/c4140/sas-raid"
    },
    {
      "slug": "serial-ata",
      "label": "Serial ATA",
      "count": 34,
      "rss": "/c4140/serial-ata/rss.xml",
      "api": "/api/c4140/serial-ata"
    },
    {
      "slug": "systems-management",
      "label": "Systems Management",
      "count": 2,
      "rss": "/c4140/systems-management/rss.xml",
      "api": "/api/c4140/systems-management"
    },
    {
      "slug": "video",
      "label": "Video",
      "count": 1,
      "rss": "/c4140/video/rss.xml",
      "api": "/api/c4140/video"
    }
  ],
  "count": 8,
  "updates": [
    {
      "id": "ddd0e2c51b4580eb2778870b68324d237a03ac014aa8e6f1d071efa03f75333c",
      "name": "BOSS-S2 Firmware",
      "version": "2.5.13.4009",
      "release_id": "TTR5R",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-09-25T07:01:26Z",
      "released": "2023-02-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER09232098M/7/SAS-RAID_Firmware_TTR5R_WN64_2.5.13.4009_A01_06.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=TTR5R",
      "size": 22410088,
      "reboot_required": true,
      "description": "BOSS-S2 ROM version 2.5.13.4009",
      "revision_history": "Fixes:\n\n-- Addressed false M.2 failures reported due to thermal issues \n               \nEnhancements:\n-- Added new SDID 0x2261 on BOSS-S2 controller"
    },
    {
      "id": "40a5d823af38ca2ebe7cbf8287901fe09aafe6fca47e6048df8429e0f104815d",
      "name": "Microsoft Windows x64 management driver for BOSS",
      "version": "1.2.0.1052",
      "release_id": "8KKVC",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Optional",
      "type": "DRVR",
      "posted": "2026-08-31T12:12:02Z",
      "released": "2021-07-09T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07524633M/9/SAS-RAID_Driver_8KKVC_WN64_1.2.0.1052_A02_08.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=8KKVC",
      "size": 17014984,
      "reboot_required": false,
      "description": "Microsoft Windows x64 management driver for BOSS",
      "revision_history": "Fixes: None,\nEnhancements: YES , Signed Binaries\nConsole Management Driver for all Windows Operating systems\nSupport for Windows Azure HCI Stack \u0026 Windows 2022 enabled"
    },
    {
      "id": "1aa67fe97be9b69f74c41d082bf3193e5c0511a1cbaac86f436a4b56b04d5149",
      "name": "BOSS-S1 Adapter firmware",
      "version": "2.5.13.3024",
      "release_id": "3P39V",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2026-08-28T11:06:39Z",
      "released": "2020-05-08T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER06189651M/8/SAS-RAID_Firmware_3P39V_WN64_2.5.13.3024_A07_07.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=3P39V",
      "size": 23542088,
      "reboot_required": true,
      "description": "BOSS-S1 Adapter ROM version 2.5.13.3024",
      "revision_history": "Fixes:YES\nFixed PPID Discrepancy for M.2 drives of BOSS controller in iDRAC Hardware inventory page\nFixed an issue to resolve the Offline Bundle installation of ESXi 6.x CLI via VUM\nFixed a behavior in firmware to handle when create \u0026 delete VD command execute in loop.\nEnhancements:YES\nNew unified BOSS Console/Management driver for all Windows operating systems."
    },
    {
      "id": "8ad48dc6cae6e8b03aebff02644f0ded7985077dfa26073f61c431a78bdd9861",
      "name": "PERC H840 Controller Firmware 51.16.0-5148",
      "version": "51.16.0-5148",
      "release_id": "M9DDF",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "FRMW",
      "posted": "2026-06-04T14:19:06Z",
      "released": "2023-10-04T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER10676386M/2/SAS-RAID_Firmware_M9DDF_WN64_51.16.0-5148_A18_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=M9DDF",
      "size": 19972656,
      "reboot_required": true,
      "description": "This release updates the firmware residing on H840 controllers to package 51.16.0-5148",
      "revision_history": "Improved DDR4 Memory settings to prevent critical DDR4 memory errors that may result in controller hang conditions, including Single Bit Errors (SBE) and Multi Bit Errors (MBE).\n\nImportant Note: After the firmware update, it is crucial to perform a complete graceful shutdown to power off the system, followed by a power on to enable the new memory settings.\nA warm reboot will NOT activate the updated settings.\nIf iDrac/LC is used to perform the update, a graceful shutdown to power off after the update is still required."
    },
    {
      "id": "9919a72526e3192f77c158c625e5ec4efa06638905b3c239de5820e669db369e",
      "name": "BOSS Console Management driver for WS2022-2025",
      "version": "1.2.0.1055",
      "release_id": "7004G",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "DRVR",
      "posted": "2024-12-18T11:18:14Z",
      "released": "2024-07-16T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11846807M/2/SAS-RAID_Driver_7004G_WN64_1.2.0.1055_A00_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=7004G",
      "size": 12936864,
      "reboot_required": false,
      "description": "BOSS Console Management driver for WS2022-2025",
      "revision_history": "Fixes: None,\nEnhancements: Console Management Driver enablement for MS Windows 2025."
    },
    {
      "id": "c262b14586cfb8f23d28fd4fce1526b82bc29af8589298cb407fb7b8956acf5b",
      "name": "Windows Server 2022 64bit driver for PERC S140 Controller",
      "version": "5.11.0.0003",
      "release_id": "85R54",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T17:21:48Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422921M/1/SAS-RAID_Driver_85R54_WN64_5.11.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=85R54",
      "size": 6633192,
      "reboot_required": true,
      "description": "Windows Server 2022 64bit driver for PERC S140 Controller"
    },
    {
      "id": "c1ad7f22b60acedb99114f7c68abbc599cad01da466bb6ed704a1888f7280388",
      "name": "Windows Server 2019 64bit driver for PERC S140 Controller",
      "version": "5.11.0.0003",
      "release_id": "P74H3",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Urgent",
      "type": "DRVR",
      "posted": "2024-03-26T17:21:17Z",
      "released": "2024-03-25T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER11422918M/1/SAS-RAID_Driver_P74H3_WN64_5.11.0.0003_A00.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=P74H3",
      "size": 6632656,
      "reboot_required": true,
      "description": "Windows Server 2019 64bit driver for PERC S140 Controller"
    },
    {
      "id": "0e605d9211bcd8a02a879473d78eea4e314ae0715828727db3f5114b6575d264",
      "name": "PERC H740P/H840/H745 RAID Controller Firmware 51.16.0-4076",
      "version": "51.16.0-4076",
      "release_id": "F3J22",
      "category": "SAS RAID",
      "category_slug": "sas-raid",
      "importance": "Recommended",
      "type": "FRMW",
      "posted": "2024-02-21T23:49:16Z",
      "released": "2021-07-19T00:00:00Z",
      "download_url": "https://downloads.dell.com/FOLDER07551659M/2/SAS-RAID_Firmware_F3J22_WN64_51.16.0-4076_A16_01.EXE",
      "info_url": "https://www.dell.com/support/home/us/en/19/Drivers/DriversDetails?driverId=F3J22",
      "size": 26112328,
      "reboot_required": true,
      "description": "This release updates the firmware residing on PERC H740P, H840, and H745 controllers to package 51.16.0-4076",
      "revision_history": "Fixes: \n\n    -Fixed issue where controller would fault on boot in systems with multiple backplanes.\n    -Fixed issue where Medium Errors found on drives were not reported during rebuilds and copybacks.\n    -Fixed issue where controller would fault during a firmware downgrade.\n    -Fixed issue where Bad PHY events were incorrectly reported.\n    -Fixed issue where SATA Drives where controller would take too long to timeout a link recovery on an unresponsive drive."
    }
  ]
}
